+ All Categories
Home > Documents > Delta Review for SNPP OMPS SDR Earth View Products€¦ · 17.08.2015 · Delta Review for SNPP...

Delta Review for SNPP OMPS SDR Earth View Products€¦ · 17.08.2015 · Delta Review for SNPP...

Date post: 03-May-2018
Category:
Upload: nguyenlien
View: 224 times
Download: 5 times
Share this document with a friend
34
Delta Review for SNPP OMPS SDR Earth View Products NOAA/NESDIS/STAR August 17, 2015 OMPS SDR Team Fuzhong Weng
Transcript

Delta Review for SNPP OMPS SDR Earth View Products

NOAA/NESDIS/STAR

August 17, 2015

OMPS SDR Team

Fuzhong Weng

Outlines

• OMPS SDR Team Members • Products and Users • Past Reviews of OMPS EV SDR and Issues • Declaring OMPS EV Validated Maturity • Requirements and Performance • Milestones since Provisional Maturity • Other Accomplishments • Path Forward for SNPP • Supporting Materials

2

OMPS SDR Team

PI Name Organization Primary Roles

Fuzhong Weng NOAA/STAR Budget and coordination; instrument and product performance monitoring; TOMRAD/VLIDORT modeling

Chunhui Pan NOAA/STAR NOAA Technical Lead; OMPS SDR cal/val science, code development, TVAC data analysis; SDR algorithm.

Glen Jaross NASA Instrument scientist; TVAC data acquisition and analysis; SDR algorithm.

Maria Caponi Aerospace Algorithm changes coordination; DR and issues tracking

Sarah Lipscy BATC Instrument sciences; prelaunch test; Sensor Characterization Data Bases (SCDB)

Wael Ibrahim Raytheon IDPS operations

3

Products and Users

• Products – OMPS nadir mapper (NM) and nadir profiler

(NP) earth view (EV) and calibration (CAL) SDR in both nominal and diagnostic mode.

• Users

– OMPS EDR Team (NCEP assimilates OMPS EDR)

– Broader and future users via CLASS

4

OMPS EV SDR Maturity Review and Issues

• Beta maturity since March 2012 • Provisional maturity since 1 March 2013

– Resolved all three issues recommended before EV SDR became provisional – weekly update darks, resolved negative smear and applied stray light correction for NM

• Validated maturity review December, 2013 and Delta review June 2014. – Recommend to resolve two issues before EV SDR becomes validated:

• Improve cross-track effects in NM (aka scan direction dependent error).

• Improve stray-light correction in NP

5

Milestones since Provisional Maturity

• Improved cross-track effects in NM. The current NM normalized

EV radiance meet the SDR product requirement (bias < 2.0%). • Updated wavelength LUT and solar flux LUT • Validated wavelength dependent cross-track irradiance error from solar

observation data • Validated wavelength dependent cross-track normalized radiance error

from SDR EV data via. TOMRAD • Validated cross-track SO2 index variation from NM EDR data

• Re-evaluated NP straylight correction. SDR and EDR teams concurs that current stray light LUT provides adequate calibration for NP. • The NP stray light calibration LUT was in operation in March 2014.

6 6

Other Accomplishments

• Instrument and SDR performance monitoring, characterization, and improvement.

• Improvement of EV normalized radiance consistency between NP and NM by 2-10% in 300-310 nm.

• Instrument cal/val support (e.g., orbit adjustment, anomaly resolution)

• Complete documentation (Users’ Guide) • Weekly dark LUTs update and delivery • CCR 2546, 7825 and 7826 modified CDFCB and xml files • CCR 2548 NP radiometric LUTs updated and delivered • SDR software improved: stray light correction

7

Declaring OMPS EV SDR Validated Maturity

8

• OMPS EV SDRs meet SDR performance requirement as well as EDR products requirement

The cross-track direction radiance accuracy meets spec and the error is less than 2.0% with updated wavelength and day one solar LUTs

The NM and NP consistency in 300-310 nm has been improved by 2-10% with updated radiance calibration coefficients

Sensor orbital performance is stable and meet expectation • OMPS EV SDRs have following features

On-orbit sensor performance is characterized SDR product uncertainties are defined for representative conditions Calibration parameters are adjusted according to EDR requirement High quality documentation is completed SDR data is ready for applications and scientific publication

• Both OMPS NM and NP EV SDR should be declared as validated-maturity products, effective August 20th 2015 !

NM Requirements and Performance

Budget Term Requirement/Allocation On-Orbit Performance Non-linearity < 2% full well < 0.40%

Non-linearity Accuracy < 0.2% < 0.2% On-orbit Wavelength

Calibration < 0.01 nm

<0.01 nm

Stray Light NM Out-of-Band + Out-of-Field

Response

≤ 2 ≤ 2%

Intra-Orbit Wavelength Stability

Allocation (flow down from EDR error budget) = 0.02 nm

~ 0.006 nm

SNR 1000 > 1000 Inter-Orbital Thermal

Wavelength Shift Allocation (flow down from

EDR error budget) = 0.02 nm ~0.006 nm

CCD Read Noise 60 –e RMS < 25 –e RMS Detector Gain 46 51

Absolute Irradiance Calibration Accuracy

< 7% < 7% for most of the channels

Absolute Radiance Calibration Accuracy

< 8% < 8%

Normalized radiance Calibration Accuracy

< 2% < 2%

9

Budget Term Requirement/Allocation On-Orbit Performance Non-linearity < 2% full well < 0.3%

Non-linearity Accuracy < 0.2% < 0.2% On-orbit Wavelength

Calibration < 0.01 nm

~0.02 nm

Stray Light NP Out-of-Band + Out-of-Field

Response

≤ 2 ≤ 2% for most of the

channels

Intra-Orbit Wavelength Stability

Allocation (flow down from EDR error budget) = 0.02 nm

~ 0.02 nm

SNR 45-400 channel dependent meet requirement Inter-Orbital Thermal

Wavelength Shift Allocation (flow down from

EDR error budget) = 0.02 nm ~0.02 nm

CCD Read Noise 60 –e RMS < 25 –e RMS Detector Gain 43 47

Absolute Irradiance Calibration Accuracy

< 7% < 7% for most of the channels

Absolute Radiance Calibration Accuracy

< 8% < 8%

Normalized radiance Calibration Accuracy

< 2% < 2%

10

NP Requirements and Performance

Path Forward for SNPP Further Improvement

11

• Continue instrument and SDR performance monitoring, characterization, and improvement.

• Support instrument cal/val (e.g., orbit adjustment, anomaly resolution)

• Carry out intra-orbital wavelength correction • Transition from CAL SDR operation to GRAVITE. • More comprehensive radiative transfer simulations at

shorter wavelengths

Supporting Materials for Declaring OMPS EV SDR Validated Maturity Products

12 12

Building on-Orbit Truth for Estimating OMPS Earth View SDR Accuracy

• Develop the “truth” simulated from the forward radiative

transfer model at OMPS EV location (Macropixel)

• Radiative transfer model must include comprehensive scattering and absorption processes at UV regions

• Accurate understanding of atmospheric and surface status at OMPS EV location.

• The difference between observations and simulations is used as an estimate of on-board calibration accuracy

13 13

OMPS EV Radiative Transfer Simulations

• TOMRAD-2.24: TOMS (Total Ozone Mapping Spectrometer)

Radiative Transfer Model • Rayleigh scattering atmosphere with ozone and other gaseous absorption • Spherical correction for the incident team • Molecular anisotropy and Raman scattering

• Inputs to TOMRAD • Wavelength, solar and satellite viewing geometry, surface albedo, temperature

and ozone profile • Climatology temperature profile • Ozone profile from Aura Microwave Limb Sounder (MLS) • Collocated OMPS/MLS data generated at NASA

• Outputs from TOMRAD • Normalized radiance (NR=reflected radiance/solar flux) or N-Value (N=-

100*log10NR)

14 14

Co-located OMPS/MLS Temperature and Ozone Profiles

Simulated Normalized Radiance at OMPS Macropixel Position 19

Normalized Radiance Observation - Simulation (O-B) (O-B)19 - (O-B)18

Relative Error Relative error wrt to Position 18 (nadir)

Observation minus Simulation (O-B)

The bias in cross-track direction is generally less than 2% except at shorter wavelengths where simulations may become less accurate due to complex scattering process. The bias is also larger in side pixel locations

Observation minus Simulation at Wing Positions

The biases at far wing positions (1-4 and 33-36) are out of specifications at wavelengths less than 320 nm. The causes can be related to complex RT processes, etc.

Observation minus Simulation near Center

The biases near center all meet specifications at all wavelengths

Observation minus Simulation (NOAA vs. NASA)

The bias characteristics simulated from NOAA (left red curves) and NASA (left blue curves) are consistent in cross-track direction and wavelength domain.

Error vs. Scan Position

Wavelength-dependent normalized radiance errors are within 2% (except for FOV 36) which meets the performance requirement.

e Cross-Track Difference

for Earth View N-Value or Radiance Wavelength-dependent Cross-Track Normalized Radiance Error Meets Requirement

22

CT position #1 CT position #9 CT position #19

CT position#26 CT position#35 CT position #36

• Normalized radiance error is percent difference between OMPS and MLS via. TOMRAD

• Figures shows the errors for 6 different cross-track (CT) positions

• Errors were minimized < 2% for most of the channels.

•Except ion is CT#36 on wavelength > 360 nm. Soft calibration are being implemented to eliminate this residual error.

Previous wavelength LUT cause errors in cross-track position.

Updated wavelength LUT eliminates errors in cross-track position.

𝐸𝐸𝐸𝐸𝐸𝐸𝐸𝐸𝐸𝐸 = �1 −𝑓𝑓𝑓𝑓𝑓𝑓𝑓𝑓𝐸𝐸𝑜𝑜𝑜𝑜𝑜𝑜𝐸𝐸𝑜𝑜𝑜𝑜𝑜𝑜𝑓𝑓𝑓𝑓𝑓𝑓𝑓𝑓𝑜𝑜𝑠𝑠𝑠𝑠𝑠𝑠 ℎ𝑜𝑜𝑠𝑠𝑒𝑒𝑒𝑒

� ∗ 100

Solar Irradiance (Flux) Cross-Track Difference for NM

Solar irradiance error in cross-track direction is eliminated. 23

• Irradiance error is percent difference between observed solar flux and modeled solar synthetic flux.

• Figures show the errors for 6 different cross-track position relative to the nadir position • Updated wavelength and solar flux LUTs have eliminated cross-track irradiance error .

• Up to 2.5 -3.0 % improvement has been achieved

Wavelength Dependent Cross-Track Solar Irradiance Error Was Eliminated

-20 -13 -7 0 7 13 20

SO2 Index Comparison before and after Wavelength Update

• SO2 index cross-track variation was minimized from -15 ~ 13 to 6~7.

• Residual error are caused by EDR V7 TOZ algorithm, that inappropriately exaggerates the impact of wavelength variation.

• The residual error can be corrected by EDR V8 algorithm with an appropriate n-value adjustment.

• Data comes from OMPS NM EDR products INCTO SO2 2015/07/01

Previous data

Reduced Cross-Track Dependence in OMPS NM Derived EDR (SO2)

24

Updated data

25

Prelaunch predicted SL contamination Orbital 19048 corrected SL contamination

Improved OMPS NP Stray-Light Correction (1/2)

Example of orbital stray light correction vs. prelaunch predicted value shows that the orbital stray light correction is adequate across all the wavelengths

Improved OMPS NP Stray-Light Correction (2/2)

26

Earth-view Mg II Index for March 2014 Change in EV Mg II index reflects stray light correction. Mg II index varied with SZA before the NP stray light correction. Stray light contamination caused up to -1. ~ 5.% errors in EV radiance The errors are within ±2% for the most of the channels after stray light correction was applied.

Before stray light correction

After stray light correction

Solar azimuth angle dependent correction residual is caused primarily by the ring effect.

Normalized Radiance: rad/irad

Original LUT Updated LUT

NP NM

Ratio Radiance before/after Updates

NP NM

Additional Improvement in Radiometric Calibration (1/2)

Updated radiance coefficient LUTs improve normalized radiance consistency up to ~10% between NP and NM in 300-310 nm.

• Radiance/irradiance coefficients were modified to account for ground to orbit wavelength shifts, as well as normalized radiance consistency between NP and NM

• Updated day-one solar LUT accounts for updated irradiance cal coefficients.

27

NM & NP consistency in SDR radiance is improved by ~2-10%.

• The improvement was validated via SDR products from both NP and NM. • EV Radiance from NP and NM are collocated spatially and spectrally • 1174 granules (globe coverage) were used for validation • Radiance is computed via old LUTs (V0), updated wavelength & day one solar (V1) and updated wavelength, day one solar, radiance/irradiance LUTs (V2)

Radiance ratio of NP/TC Percent difference (1-v0/v2)*100 before and after LUTs update

Improvement in the Spectral Range of 300 - 310 nm

V0 V1 V2

Radiance ratio of NP/TC

Additional Improvement in Radiometric Calibration (2/2)

28

29 Sensor optical degradation < 1.0 %.

Monitoring OMPS Solar Diffuser Degradation

30

Errors from work diffuser measurements Errors from Reference diffuser measurements

Channels with large noise

OMPS Solar Irradiance Errors Measured from Solar Diffusers

Irradiance error meets the requirement of 7% for most of the channels.

31

OMPS System Nonlinearity

System nonlinearity meets the requirement of 2%.

Equivalent to SNR 1000

Data collected from 1178 EV granules on July 1, 2015

Sensor Signal to Noise Ratio from EV data

Sensor signal to noise ratio from EV data meets the requirement of 1000. 32

Bias drifts are small for both sensors. Sometime, unexpected bias drifts are observed, but do not have negative impact on the SDRs since the magnitudes in general are small.

NP NM Left CCD

OMPS Solar Diffuser Count Drafts

33

Dark data shows a bump-up trend after the spacecraft maneuver. • NM slowly returns to the original trend and the change rate is slowing down • NP has a static offset of 8.1e-3 count/sec in mean dark and parallel with the original trend.

OMPS Dark Current Trend

Dark increases as expected. Dark changes have no significant impact on SDRs. 34


Recommended