DEPARTMENT OF GENERAL SERVICES DIVISION OF THE STATE ...

Date post: 18-Dec-2021
Category:
Upload: others
View: 0 times
Download: 0 times
Share this document with a friend
3
RD Gate Ramp x x x x x x x (E) MAIN ADMIN. BUILDING A#39042 (E) RELO FU (E (E) SHADE STRUCTURE (E) RELOCATABLES CHILDCARE (E) ACCESSIBLE RAMP A#103962 (E) RELOCATABLES KINDERGARTEN A#107278 (E) RELOCATABLES KINDERGARTEN A#107278 (E) RELOCATABLES KINDERGARTEN A#103962 (E) RELOCATABLES KINDERGARTEN A#103962 (E) RELOCAT CHILDCA P.A P.A P.A P.A (N) PLAY AREA BASEBALL BACKSTOP P.A 4'-0" HIGH W/ FENCE GUARD PROTECTIVE COVER (E) SHADE STRUCTURE RD Gate Ramp x x x x x x x x x x x x H Y D x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C4 16 1" C5 6 1" C6 44 2" C7 3.5 1" C1 23 1" C2 22 1" C3 13 1" C I R R I G A T I O N L E G E N D RAD PSI GPM DESCRIPTION SYM 1" 1.25" 1.5" SCH 40 1" PURPLE PVC LATERAL PIPE SCH 40 1-1/4" PURPLE PVC LATERAL PIPE SCH 40 1-1/2" PURPLE PVC LATERAL PIPE SCH 40 3/4" PURPLE PVC LATERAL PIPE NIBCO 3" T-113 BRONZE GATE VALVE 2" SCH 40 2" PURPLE PVC LATERAL PIPE 3" CLASS 315 PURPLE PVC MAINLINE PR EXISTING CONTROLLER DESIGNATION VALVE SIZE GALLONS PER MINUTE G1 12 1" SUPERIOR 950 - SIZE NOTED ON PLAN. NOTES IN AREAS WHERE TREE REMOVAL AND/OR PAVING REMOVAL WILL OCCUR, THE LANDSCAPE CONTRACTOR SHALL 1. BE PRESENT TO VERIFY EXISTING IRRIGATION CONDITIONS AND TAKE REASONABLE PROTECTIVE MEASURES TO ENSURE CONTINUED OPERATION OF THE SYSTEM BEYOND THE LIMIT OF WORK. 2. VISIT THE SITE PRIOR TO TREE REMOVAL AND PAVING INSTALLATION AND MARK EXISTING IRRIGATION EQUIPMENT THAT SHALL BE REASONABLY PROTECTED. FOLLOWING TREE REMOVAL AND PAVING INSTALLATION, THE EXISTING IRRIGATION SYSTEM SHALL BE REPAIRED OR REPLACED AS NECESSARY TO MAINTAIN 100% HEAD-TO-HEAD COVERAGE USING MATCHING EQUIPMENT. DRIPLINE NOTES: THE IRRIGATION SYSTEM ASSUMES A MINIMUM FLOW OF 90-GPM AND A MINIMUM PRESSURE OF 55-PSI IS AVAILABLE ON THE EXISTING IRRIGATION MAINLINE. ALL LATERAL LINES AND MAINLINES UNDER PAVING SHALL BE SLEEVED IN SCH. 40 PVC 2-TIMES PIPE DIAMETER. INSTALL ALL LINES WITHIN PLANTER AREAS. MAINLINES AND LATERAL LINES ARE SHOWN OUTSIDE OF PLANTERS FOR PLAN CLARITY ONLY. ALL IRRIGATION EQUIPMENT SHALL BE INSTALLED IN PURPLE COLOR BOXES. LARGE RECTANGULAR VALVE BOXES FOR REMOTE CONTROL VALVES. 4.00 40' 45 HUNTER 1-20-4.0 W/PURPLE CAP 0.48 8.00 44' 45 HUNTER 1-20-8.0 W/PURPLE CAP 0.80 A B 0.167 0' 20 NA RAINBIRD 1804-PCT010 W/PA80 ADAPTER. INSTALL 3 PER TREE-EQUALLY SPACED. 3" SCH 40 3" PURPLE PVC LATERAL PIPE RECYCLED WATER NOTES: 1. ALL VALVE BOXES SHALL BE PURPLE PLASTIC WITH THE WORDS “RECYCLED WATER” CAST INTO THE PLASTIC LID. 2. ALL CONTROL VALVES MUST HAVE A PLASTIC LABEL ATTACHED WITH A NYLON TIE WRAP WITH THE WORDS “RECYCLED WATER – DO NOT DRINK” IN ENGLISH AND SPANISH. 3. ALL ABOVE-GROUND RISERS SHALL BE LABELED WITH A SELF-ADHESIVE LABEL WITH THE SAME WARNING AS THE LABEL FOR CONTROL VALVES. 4. ALL FLUSH, POP-UP SPRINKLER HEADS MUST BE MADE OF PURPLE PLASTIC. 5. ALL BELOW GRADE PIPING MUST BE PURPLE PIPE WITH THE WORDS “RECYCLED WATER – DO NOT DRINK”. THIS APPLIES TO BOTH PERMANENT AND INTERMITTENT PRESSURE PIPE. THIS REQUIREMENT DOES NOT APPLY TO FITTINGS AND RISERS. 6. NO HOSE BIBS ARE ALLOWED ON RECYCLED WATER SYSTEMS. 7. QUICK COUPLERS ARE ALLOWED, BUT MUST BE MADE FOR RECYCLED WATER SYSTEMS. QUICK COUPLERS MUST ALSO BE PLACED IN PURPLE PLASTIC VALVE BOXES. 8. NO ON-SITE BACKFLOW PREVENTION ASSEMBLY SHALL BE ALLOWED ON ANY RECYCLED WATER SYSTEM SERVING LANDSCAPE, TURF, OR CROP IRRIGATION. 9. SIGNS INDICATING THE USE OF RECYCLED WATER ARE REQUIRED AND WILL BE PLACED AT THE DISCRETION OF THE DISTRICT INSPECTOR. 10. PRIOR TO PRESSURE TESTING, POTABLE WATER WITH AN APPROVED REDUCED PRESSURE PRINCIPLE DEVICE MAY BE TEMPORARILY USED TO ESTABLISH PLANTING. THE SYSTEM MUST BE CHECKED FOR CROSS-CONNECTIONS BEFORE CONVERTING TO RECYCLED WATER. 11. POTABLE WATER IS REQUIRED DURING INITIAL PRESSURE TESTING. 12. ALL REQUIRED PERMITS TO BE COMPLETED AND SIGNED BEFORE ACTIVATION OF RECYCLED WATER. 13. IRRIGATION MAY ONLY TAKE PLACE WHEN THE GENERAL PUBLIC IS NOT PRESENT, TYPICALLY BETWEEN 10 P.M. AND 6 A.M., OR OTHERWISE SPECIFIED BY THE RECLAIMED WATER PURVEYOR AND/OR PRODUCER. IRRIGATION MAY TAKE PLACE AT OTHER TIMES IF MANUALLY CONTROLLED AND SUPERVISED (I.E. TRAINED USE SITE STAFF IS PRESENT) TO ENSURE RECYCLED WATER DOESN’T COME IN CONTACT WITH THE PUBLIC. 14. THERE MUST NEVER BE A DIRECT CONNECTION BETWEEN THE RECYCLED WATER SYSTEM AND THE POTABLE WATER SYSTEM AFTER RECYCLED SERVICE HAS BEEN ESTABLISHED. 15. INSTALLATION OF RECYCLED WATER IRRIGATION SHALL COMPLY WITH THE REQUIREMENTS OF ARTICLE 9 OF THE DISTRICT’S RULES AND REGULATIONS AND COUNTY OF LOS ANGELES DEPARTMENT OF PUBLIC HEALTH. REQUIRED CLEARANCE BETWEEN POTABLE AND RECYCLED WATER LINES IS 10 FEET HORIZONTALLY AND 1 FOOT VERTICALLY (WITH POTABLE WATER LINE CROSSING PERPENDICULARLY OVER RECYCLED WATER LINE). IF A RECYCLED WATER LINE CROSSES OVER A POTABLE WATER LINE, THE RECYCLED WATER LINE SHALL BE INSTALLED INSIDE A SLEEVE WITH THE SLEEVE CENTERED OVER THE POTABLE WATER LINE AND EXTENDED AT LEAST 10 FEET ON BOTH SIDES. NOTIFY BOB YAMAGUCHI AT WALNUT VALLEY WATER DISTRICT AT (909) 595-1268 FOR HIS OBSERVATIONS AND INSPECTIONS: 1) INSPECT PIPE PRIOR TO BACKFILL; 2) INITIAL PRESSURE TEST; AND 3) ABOVE-GROUND INSPECTION – 2 DAY NOTIFICATION. L.A. COUNTY MUST ALSO DUAL PRESSURE OR DYE TEST THE SYSTEM BEFORE ALLOWING PERMANENT CONNECTION. NOTIFY BOB YAMAGUCHI (W.V.W.D.) AND DAN BACANI (L.A. COUNTY) AT (626) 430-5290, FOR FINAL INSPECTIONS 2 DAY NOTIFICATION. 2.0 34' 45 HUNTER 1-20-4.0 W/PURPLE CAP 0.33 C RAINBIRD 1806-RVAN-8-14 @ HALF-CIRCLE SETTING 0.63 14' 45 0.62 0.083 0' 20 NA RAINBIRD 1804-PCT05 W/PA80 ADAPTER. INSTALL 1 PER SHRUB IN WATER BASIN. LINE SIZE PVC SWING CHECK VALVE. MANUF. TO BE APPROVED RAINBIRD ESP-12LXMEF CONTROLLER. MOIUNT ON EXTERIOR WALL IN VIT STRONBOX LD-18SW. COORDINATE POWER SUPPLY PRIOR TO INSTALLATION. C PROJECT NUMBER: DATE: REVISION: DESCRIPTION: PROJECT STATUS: PROJECT ISSUED: © 2019 SGH ARCHITECTS INC. ALL RIGHTS RESERVED SEALS: CONSULTANT: 9/16/2020 5:17:24 PM 19-47101-00 NEW MULTIPURPOSE & CLASSROOM BUILDING 841 GLENWICK AVE., WALNUT, CA91789 WALNUT ELEMENTARY SCHOOL WALNUT VALLEY USD 100% CD 12/10/20 SCALE: LANDSCAPE PLAN silver bar studio landscape architecture environmental design mariposa, ca. 2903 JULY 2022 L1.01 IRRIGATION PLAN DSA DEPARTMENT OF GENERAL SERVICES DIVISION OF THE STATE ARCHITECT DSA DIVISION OF THE STATE ARCHITECT IDENTIFICATION STAMP DIV. OF THE STATE ARCHITECT APP: INC: REVIEWED FOR SS FLS ACS DATE: 03-121157 07/19/2021
Transcript

RD

Gate

Ramp

x

x

x

x

x

xx

(E) MAIN ADMIN. BUILDINGA#39042

(E) RELOCATABLES

FUN CLUB

A#107278

(E) RELOCATABLES

(E) SHADE

STRUCTURE

(E) RELOCATABLES

CHILDCARE

(E) ACCESSIBLE RAMPA#103962

(E) RELOCATABLESKINDERGARTEN

A#107278

(E) RELOCATABLESKINDERGARTEN

A#107278

(E) RELOCATABLESKINDERGARTEN

A#103962

(E) RELOCATABLESKINDERGARTEN

A#103962

(E) RELOCATABLES

CHILDCARE

P.A

P.A

P.A

P.A

(N) PLAY AREA

BASEBALLBACKSTOP

P.A

4'-0" HIGH W/ FENCEGUARD PROTECTIVECOVER

(E) SHADE

STRUCTURE

RD

Gate

Ramp

x

x

x

x

x

x

xx

x

x

x

x

x

H

Y

D

x

x

x

x

x

x

x

x

x

x

x

x

xx

x

xx

xx

x

x

x

x

x

x

x

x

x

x

x

x

x

x

CC

C

C

C

C

C

C

C

C

C

C

C

C

C

C

C

C

C

C

C

C

C

C

C

C

C

C

C

C4

16

1"

C5

6

1"

C6

44

2"

C7

3.5

1"

C1

23

1"

C2

22

1"

C3

13

1"

C

I R R I G A T I O N L E G E N D

RADPSIGPMDESCRIPTIONSYM

1"

1.25"

1.5"

SCH 40 1" PURPLE PVC LATERAL PIPE

SCH 40 1-1/4" PURPLE PVC LATERAL PIPE

SCH 40 1-1/2" PURPLE PVC LATERAL PIPE

SCH 40 3/4" PURPLE PVC LATERAL PIPE

NIBCO 3" T-113 BRONZE GATE VALVE

2"SCH 40 2" PURPLE PVC LATERAL PIPE

3" CLASS 315 PURPLE PVC MAINLINE

PR

EXISTING CONTROLLER DESIGNATION

VALVE SIZE

GALLONS PER MINUTE

G1

12

1"

SUPERIOR 950 - SIZE NOTED ON PLAN.

NOTES

IN AREAS WHERE TREE REMOVAL AND/OR PAVING REMOVAL WILL OCCUR,

THE LANDSCAPE CONTRACTOR SHALL

1. BE PRESENT TO VERIFY EXISTING IRRIGATION CONDITIONS AND TAKE

REASONABLE PROTECTIVE MEASURES TO ENSURE CONTINUED

OPERATION OF THE SYSTEM BEYOND THE LIMIT OF WORK.

2. VISIT THE SITE PRIOR TO TREE REMOVAL AND PAVING INSTALLATION

AND MARK EXISTING IRRIGATION EQUIPMENT THAT SHALL BE

REASONABLY PROTECTED.

FOLLOWING TREE REMOVAL AND PAVING INSTALLATION, THE EXISTING

IRRIGATION SYSTEM SHALL BE REPAIRED OR REPLACED AS NECESSARY TO

MAINTAIN 100% HEAD-TO-HEAD COVERAGE USING MATCHING EQUIPMENT.

DRIPLINE NOTES:

THE IRRIGATION SYSTEM ASSUMES A MINIMUM FLOW OF 90-GPM AND A MINIMUM

PRESSURE OF 55-PSI IS AVAILABLE ON THE EXISTING IRRIGATION MAINLINE.

ALL LATERAL LINES AND MAINLINES UNDER PAVING SHALL BE SLEEVED IN SCH.

40 PVC 2-TIMES PIPE DIAMETER.

INSTALL ALL LINES WITHIN PLANTER AREAS. MAINLINES AND LATERAL LINES

ARE SHOWN OUTSIDE OF PLANTERS FOR PLAN CLARITY ONLY.

ALL IRRIGATION EQUIPMENT SHALL BE INSTALLED IN PURPLE COLOR BOXES.

LARGE RECTANGULAR VALVE BOXES FOR REMOTE CONTROL VALVES.

4.00 40'45HUNTER 1-20-4.0 W/PURPLE CAP

0.48

8.00 44'45HUNTER 1-20-8.0 W/PURPLE CAP

0.80

A

B

0.167 0'20 NA

RAINBIRD 1804-PCT010 W/PA80 ADAPTER.

INSTALL 3 PER TREE-EQUALLY SPACED.

3"

SCH 40 3" PURPLE PVC LATERAL PIPE

RECYCLED WATER NOTES:

1. ALL VALVE BOXES SHALL BE PURPLE PLASTIC WITH THE

WORDS “RECYCLED WATER” CAST INTO THE PLASTIC LID.

2. ALL CONTROL VALVES MUST HAVE A PLASTIC LABEL ATTACHED WITH A

NYLON TIE WRAP WITH THE WORDS “RECYCLED WATER – DO NOT

DRINK” IN ENGLISH AND SPANISH.

3. ALL ABOVE-GROUND RISERS SHALL BE LABELED WITH A SELF-ADHESIVE

LABEL WITH THE SAME WARNING AS THE LABEL FOR CONTROL VALVES.

4. ALL FLUSH, POP-UP SPRINKLER HEADS MUST BE MADE OF PURPLE

PLASTIC.

5. ALL BELOW GRADE PIPING MUST BE PURPLE PIPE WITH THE

WORDS “RECYCLED WATER – DO NOT DRINK”. THIS APPLIES TO BOTH

PERMANENT AND INTERMITTENT PRESSURE PIPE. THIS REQUIREMENT

DOES NOT APPLY TO FITTINGS AND RISERS.

6. NO HOSE BIBS ARE ALLOWED ON RECYCLED WATER SYSTEMS.

7. QUICK COUPLERS ARE ALLOWED, BUT MUST BE MADE FOR RECYCLED

WATER SYSTEMS. QUICK COUPLERS MUST ALSO BE PLACED IN PURPLE

PLASTIC VALVE BOXES.

8. NO ON-SITE BACKFLOW PREVENTION ASSEMBLY SHALL BE ALLOWED ON

ANY RECYCLED WATER SYSTEM SERVING LANDSCAPE, TURF, OR CROP

IRRIGATION.

9. SIGNS INDICATING THE USE OF RECYCLED WATER ARE REQUIRED AND

WILL BE PLACED AT THE DISCRETION OF THE DISTRICT INSPECTOR.

10. PRIOR TO PRESSURE TESTING, POTABLE WATER WITH AN APPROVED

REDUCED PRESSURE PRINCIPLE DEVICE MAY BE TEMPORARILY USED TO

ESTABLISH PLANTING. THE SYSTEM MUST BE CHECKED FOR

CROSS-CONNECTIONS BEFORE CONVERTING TO RECYCLED WATER.

11. POTABLE WATER IS REQUIRED DURING INITIAL PRESSURE TESTING.

12. ALL REQUIRED PERMITS TO BE COMPLETED AND SIGNED BEFORE

ACTIVATION OF RECYCLED WATER.

13. IRRIGATION MAY ONLY TAKE PLACE WHEN THE GENERAL PUBLIC IS NOT

PRESENT, TYPICALLY BETWEEN 10 P.M. AND 6 A.M., OR OTHERWISE

SPECIFIED BY THE RECLAIMED WATER PURVEYOR AND/OR PRODUCER.

IRRIGATION MAY TAKE PLACE AT OTHER TIMES IF MANUALLY CONTROLLED

AND SUPERVISED (I.E. TRAINED USE SITE STAFF IS PRESENT) TO ENSURE

RECYCLED WATER DOESN’T COME IN CONTACT WITH THE PUBLIC.

14. THERE MUST NEVER BE A DIRECT CONNECTION BETWEEN THE RECYCLED

WATER SYSTEM AND THE POTABLE WATER SYSTEM AFTER RECYCLED

SERVICE HAS BEEN ESTABLISHED.

15. INSTALLATION OF RECYCLED WATER IRRIGATION SHALL COMPLY WITH THE

REQUIREMENTS OF ARTICLE 9 OF THE DISTRICT’S RULES AND

REGULATIONS AND COUNTY OF LOS ANGELES DEPARTMENT OF PUBLIC

HEALTH.

REQUIRED CLEARANCE BETWEEN POTABLE AND RECYCLED WATER LINES IS 10

FEET HORIZONTALLY AND 1 FOOT VERTICALLY (WITH POTABLE WATER LINE

CROSSING PERPENDICULARLY OVER RECYCLED WATER LINE). IF A RECYCLED

WATER LINE CROSSES OVER A POTABLE WATER LINE, THE RECYCLED WATER

LINE SHALL BE INSTALLED INSIDE A SLEEVE WITH THE SLEEVE CENTERED OVER

THE POTABLE WATER LINE AND EXTENDED AT LEAST 10 FEET ON BOTH SIDES.

NOTIFY BOB YAMAGUCHI AT WALNUT VALLEY WATER DISTRICT

AT (909) 595-1268 FOR HIS OBSERVATIONS AND INSPECTIONS: 1) INSPECT PIPE

PRIOR TO BACKFILL; 2) INITIAL PRESSURE TEST; AND 3) ABOVE-GROUND

INSPECTION – 2 DAY NOTIFICATION.

L.A. COUNTY MUST ALSO DUAL PRESSURE OR DYE TEST THE SYSTEM BEFORE

ALLOWING PERMANENT CONNECTION.

NOTIFY BOB YAMAGUCHI (W.V.W.D.) AND DAN BACANI (L.A. COUNTY) AT (626)

430-5290, FOR FINAL INSPECTIONS 2 DAY NOTIFICATION.

2.0 34'45HUNTER 1-20-4.0 W/PURPLE CAP

0.33C

RAINBIRD 1806-RVAN-8-14

@ HALF-CIRCLE SETTING

0.63 14'45 0.62

0.083 0'20 NA

RAINBIRD 1804-PCT05 W/PA80 ADAPTER.

INSTALL 1 PER SHRUB IN WATER BASIN.

LINE SIZE PVC SWING CHECK VALVE. MANUF. TO BE APPROVED

RAINBIRD ESP-12LXMEF CONTROLLER. MOIUNT ON EXTERIOR WALL IN

VIT STRONBOX LD-18SW. COORDINATE POWER SUPPLY PRIOR TO

INSTALLATION.

C

PROJ

ECT

NUMB

ER:

DATE

:RE

VISI

ON:

DESC

RIPT

ION:

PROJ

ECT

STAT

US:

PROJ

ECT

ISSU

ED:

© 20

19 S

GH A

RCHI

TECT

S IN

C. A

LL R

IGHT

S RE

SERV

ED

SEAL

S:CO

NSUL

TANT

:

9/16/2020 5:17:24 P

M

19-47101-00

NEW

MUL

TIPU

RPOS

E &

CLAS

SROO

M BU

ILDIN

G

841 G

LE

NW

IC

K A

VE

., W

ALN

UT

, C

A91789

WA

LN

UT

E

LE

ME

NT

AR

Y S

CH

OO

L

WA

LN

UT

V

ALLE

Y U

SD

100%

C

D

12/10/20

SCALE:LANDSCAPE PLAN

silver bar studio

landscape architecture

environmental design

mariposa, ca.

2903

JULY 2022

L1.01

IRRI

GATI

ON P

LAN

DSAD E P A R T M E N T O F G E N E R A L S E R V I C E S

DIVISION OF THE STATE ARCHITECTDSADIVISION OF THE STATE ARCHITECTDSADIVISION OF THE STATE ARCHITECTDSADIVISION OF THE STATE ARCHITECT

IDENTIFICATION STAMP DIV. OF THE STATE ARCHITECT

APP: INC:REVIEWED FOR

SS FLS ACS

DATE:

✔ ✔ ✔

03-121157

07/19/2021

PROJ

ECT

NUMB

ER:

DATE

:RE

VISI

ON:

DESC

RIPT

ION:

PROJ

ECT

STAT

US:

PROJ

ECT

ISSU

ED:

© 20

19 S

GH A

RCHI

TECT

S IN

C. A

LL R

IGHT

S RE

SERV

ED

SEAL

S:CO

NSUL

TANT

:

9/16/2020 5:17:24 P

M

19-47101-00

NEW

MUL

TIPU

RPOS

E &

CLAS

SROO

M BU

ILDIN

G

841 G

LE

NW

IC

K A

VE

., W

ALN

UT

, C

A91789

WA

LN

UT

E

LE

ME

NT

AR

Y S

CH

OO

L

WA

LN

UT

V

ALLE

Y U

SD

100%

C

D

12/10/20

SCALE:LANDSCAPE PLAN

silver bar studio

landscape architecture

environmental design

mariposa, ca.

2903

JULY 2022

L1.02

SPARE CONTROL WIRES, PROVIDE 24" LOOP AT EACH RCV

BOX TO BE PLACED AT RIGHT ANGLE TO HARDSCAPE

PLASTIC RECTANGULAR VALVE BOX WITH BOLT DOWN

COVER, USE STAINLESS BOLT, NUT, AND WASHER.

EDGE. HEAT BRAND "RCV" AND VALVE NUMBER ONTO LID.

REMOTE CONTROL

REMOTE CONTROL VALVE, SEE LEGEND FOR SPECS.

BRASS THREADED ELL, 2 REQUIRED

4"

VALVE

B11

2"

FINISHED GRADE IN TURF AREAS

4 REQ. PER BOX

BRICK SUPPORTS

PVC MAINLINE PIPE

PER SPECIFICATIONS

SCH. 80 PVC THD. NIPPLE

3/4" ROCK, 3 CUBIC FT.

MAINTAIN 12" MIN. DEPTH

TO SPRINKLER HEADS,

PVC LATERAL LINE PIPE

ELL (SLIP), 2 REQUIRED

SCH. 40 PVC 45 DEGREE

SCH. 80 PVC T.O.E. NIPPLE

WIRE CONNECTIONS

FINISHED GRADE

IN SHRUB AREAS

SCH. 80 PVC SLIP TEE

(OR A PVC SLIP 90 ELL)

BRASS ELLS, UNION AND AND ALL NIPPLES SHALL BE SIZED TO MATCH THE R.C.V., AT THE 45

DEGREE ELL INCREASE THE LATERAL SIZE TO MATCH THE SIZE INDICATED ON THE DRAWINGS.

SECTION VIEW - N.T.S.

INSTALL VALVE BOXES 12" APART AS INDICATED ON DETAIL.

EQUIPMENT SHALL BE INSTALLED SUCH THAT THERE IS NO LEVERAGE OR STRESS

ON THE VALVE ASSEMBLY. PIPE SHALL NOT COME INTO CONTACT WITH VALVE BOX.

USE A NON-HARDENING TEFLON PIPE SEALANT ON ALL THREADED CONNECTIONS.

NOTE:

NIPPLE, MIN. 12" LONG

WITH A SCH. 80 PVC T.O.E.

IRRIGATION CONTROL WIRES

SCH. 80 PVC UNION

VALVE ID TAG

UP AND OVER BOX HOLES

LANDSCAPE FABRIC, WRAP

LENGTH AS REQ., 3" MIN.

2"

1/2"

24"

24"

PIPE AND WIRE TRENCHING

18"

ALL PLASTIC PIPING SHALL BE SNAKED WITHIN TRENCH.

BUNDLE WIRING AND WRAP WITH TAPE AT TEN FOOT INTERVALS.

ALL MAINLINE PIPING TO BE INSTALLED IN ACCORDANCE WITH MANUFACTURERS

3" AND LARGER

2" TO 2 1/2" IN SIZE

1/2" TO 1 1/2" SIZE

SECTION VIEW - N.T.S.

INSTALLATION SPECIFICATIONS.

NOTE:

18"

12"

12"

DIMENSION

A

E E

D

F

E

A B

E

B

F

C

6"24"

18"

24"

30"

30"

6"

6"

6"

CLEAN SAND BACKFILL,

UNDISTURBED SOIL

IN SCH. 40 CONDUIT

INSTALL AT MAINLINE DEPTH

120 VOLT ELECTRICAL

SPECIFICATIONS

PRESSURE MAINLINE, SEE

CONTROL WIRES, SEE SPECS.

LATERAL LINES, SEE SPECS.

CLEAN COMPACTED BACKFILL

C

E

D E F

FINISHED GRADE

6"

6"

SEE SPECIFICATIONS

SLEEVE TRENCHING

ALL CURBS SHALL BE MARKED WITH A "SCORE" MARK TO DESIGNATE SLEEVE LOCATION.

ALL PVC MAINLINE, PVC LATERAL LINES, AND CONTROL WIRES SHALL BE SLEEVED

BELOW ALL HARDSCAPE ELEMENTS WITH SCH. 40 PVC, 2 TIMES THE DIAMETER OF

THE PIPE OR WIRE BUNDLE WITHIN.

PLAN VIEW - N.T.S.

NOTE:

DEPTH BELOW GRADE

DIMENSION

SECTION VIEW - N.T.S.

E E

24"

A

36"

B

E E

AD B C

30 DEGREES, UNTIE AFTER ALL CONECTIONS

CHANGES OF DIRECTION GREATER THAN

TIE A 36" LOOP IN ALL WIRING AT

HAVE BEEN MADE.

IN SCH. 40 SLEEVE

120 VOLT ELECTRICAL

EXISTING SOIL

BUNDLE CARRIED.

OF THE PIPE OR WIRE

TWICE THE DIAMETER

PVC SLEEVES TO BE

IN SCH. 40 SLEEVE

IN SCH. 40 SLEEVE

IN SCH. 40 SLEEVE

CONTROL WIRES

PRESSURE MAINLINE

LATERAL LINES

TO THE DENSITY OF

SAND BACKFILL COMPACTED

UNDISTURBED SOIL

PAVING OR D.G. PATH

36"

D

36"

C

6"

E

E

SLEEVE DETAIL SHALL ALSO BE USED FOR INSTALLATION OF PIPE IN ROCK SOIL.

WIRE CONNECTOR

LOCK TABS PREVENT WIRE REMOVAL

INTO THE CONNECTIOR. TWIST

CONNECTOR ONTO WIRES TO

INSULATION PRIOR TO INSERTION

PRE-STRIPPED OF 1/2" OF THE

CONNECTOR. WIRES SHALL BE

SCOTCHLOK ELECTRICAL SPRING

ONCE CONNECTOR IS INSERTED

CONNECTOR PASSES LOCK TABS

SCOTCHLOK CONNECTOR AND WIRES

INSERTED INTO TUBE UNTIL THE

2 #12 PRE-STRIPPED COPPER WIRES. LARGER WIRES OR GREATER QUANTITIES OF WIRES

DIRECT BURY SPLICE KIT SHALL BE USED TO ELECTRICALLY CONNECT 2 - 3 #14 OR

KIT SHALL INCLUDE A SCOTCHLOK SPRING CONNECTOR, A POLYPROPYLENE TUBE AND A

WIRE CONNECTOR SHALL BE A 3M DBY DIRECT BURY SPLICE KIT.

WATERPROOF SEALING GEL. TUBE SHALL BE SUPPLIED PREFILLED WITH GEL.

NOTE:

SEAT FIRMLY.

LOW VOLTAGE WIRES, 3 MAXIMUM

CLOSE TUBE LID AFTER WIRE

TUBE LID TO ALLOW LID TO CLOSE

WIRES PASS THROUGH GROOVES IN

IS INSERTED INTO TUBE

POLY TUBE PRE-FILLED WITH

WATERPROOF GEL

SHALL REQUIRE A LARGER APPROVED WIRE CONNECTION.

SECTION VIEW - N.T.S.

FINISHED GRADE IN TURF AREAS

SEAL CONDUIT ENDS WITH AQUASEAL

WATERPROOF ELECTRICAL CONNECTORS FOR

EDGE. HEAT BRAND "PB" ONTO LID.

COVER, USE STAINLESS BOLT, NUT, AND WASHER.

PLASTIC RECTANGULAR VALVE BOX WITH BOLT DOWN

BOX TO BE PLACED AT RIGHT ANGLE TO HARDSCAPE

ALL CONTROL WIRE SPLICES SHALL BE INSTALLED INSIDE PULL BOXES.

ALL SPLICES SHALL BE MADE USING WATERPROOF ELECTRICAL CONNECTORS.

CONTROL WIRE PULL BOX

NOTE:

BRICK SUPPORTS

LANDSCAPE FABRIC, WRAP

3/4" ROCK, 3 CUBIC FT

UP AND OVER BOX HOLES

4 REQUIRED PER BOX

SCH. 40 ELECTRICAL

IN SHRUB AREAS

LOW VOLTAGE CONTROL

FINISHED GRADE

WIRE COIL, 24" MINIMUM

2"

1/2"

UNDISTURBED SOIL

SECTION VIEW - N.T.S.

CONDUIT, WHERE REQ.,

SEE SPECIFICATIONS

OPEN END OF CONDUITS

AQUA SEAL / VAPOR LOCK

ALL WIRE SPLICES, SEE DETAIL SID038

SOLVENT

WELD

MATCH MAINLINE SIZE

FLUSH WITH FINISHED GRADE IN TURF AREAS

INSTALL PURPLE PLASTIC ROTOR SPRINKLER

ABOVE FINISHED GRADE IN SHRUB

INSTALL SPRINKLER HEAD 1/2"

1/2"

AND GROUND COVERS AREAS

NATIVE OR AMENDED SOIL

4" - 6" POP-UP ROTOR

SCH. 80 PVC NIPPLE, LENGTH AS REQUIRED

LATERAL x SPRINKLER INLET SIZE

SCH. 40 PVC SxSxT TEE FITTING

MARLEX STREET ELL, 2 REQUIRED

SCH. 40 PVC THREADED ELL

SCH. 80 PVC NIPPLE, 8" LONG

SEE LEGEND FOR SPECIFICATION

POP-UP SPRINKLER HEAD, ROTOR TYPE

INSTALL SPRINKLER HEADS PLUMB. ADJUST NOZZLE STREAM TO COVER LANDSCAPE

INSTALL SPRINKLER HEADS 4" FROM PAVING EDGE IN TURF AREAS.

CONTRACTOR ASSEMBLED SWING JOINT SHALL BE SIZED TO MATCH THE SPRINKLER INLET.

INSTALL SPRINKLER HEADS 6" FROM PAVING EDGE IN GROUND COVER AREAS.

AREA WITHOUT OVERSPRAY ONTO PAVING, FENCES, WALLS OR BUILDINGS.

USE A NON-HARDENING TEFLON PIPE SEALANT ON ALL THREADED CONNECTIONS.

NOTE:

4"-6" POP-UP SPRINKLER & BUBBLER

QUICK COUPLER VALVE

IN VALVE BOX

NOTE:

3" MAX.

LANDSCAPE FABRIC

3/4" ROCK, 1 CUBIC FT.

#4 x 36" REBAR STAKES,

PURPLE PVC MAINLINE AND

2 REQUIRED

BRICK SUPPORTS

IN SHRUB AREAS

QUICK COUPLER VALVE

FINISHED GRADE

FOR RECYCLED WATER

QUICK COUPLER KEY WITH 3/4" BRASS HOSE

STAINLESS STEEL CLAMP

SWIVEL, INSTALL QCV SO THAT KEY WILL CLEAR

FINISHED GRADE IN TURF AREAS

2"

1/2"

THE TOP OF BOX DURING OPERATION

NATIVE SOIL

UNDISTURBED OR

3 REQ. PER BOX

2 REQUIRED, SEE SPECS

SCH. 80 SLIP TEE, LABELLED

A SCH. 80 PVC T.O.E. NIPPLE,

1" x 12" MIN. LENGTH, AND A

USE A NON-HARDENING TEFLON PIPE SEALANT ON ALL THREADED CONNECTIONS.

BE 1" SIZE.

JOINT COMPONENTS SHALL

LONG SCH 80 THD. NIPPLE,

AND ONE SCH 80 THD. NIPPLE,

SCH 40 THD. ELL, ONE 12"

SCH 40 ELLS, ONE

QCV SWING JOINT, W/ TWO

1" BRASS THREADED ELL

LENGTH AS REQ. ALL SWING

SECTION VIEW - N.T.S.

PLASTIC LABEL

ATTACHED W/NYLON.

LABEL TO READ:

"RECYCLED

WATER-DO NOT

DRINK" IN ENGLISH

AND SPANISH.

"RECYCLED WATER-

DO NOT DRINK"

PURPLE PLASTIC ROUND VALVE BOX WITH BOLT DOWN COVER

W/STAINLESS STEEL BOLT, NUT AND WASHER. HEAT BRAND

COVER TO READ: "RECYCLED WATER-DO NOT DRINK" IN

ENGLISH AND SPANISH.

3" AND SMALLER

GATE VALVE

INSTALL VALVE BOX EXTENSIONS AS REQ. TO ACHIEVE PROPER VALVE AND PIPE DEPTH

BOX TO BE INSTALLED AS TO ALLOW FOR PROPER OPERATION OF BALL VALVE, INSTALL

VALVE AND BOX PARALLEL TO HARDSCAPE EDGE, INSTALL BOX OFF-CENTER OF VALVE.

FINISHED GRADE IN TURF AREAS

GATE VALVE, SEE LEGEND FOR SPECIFICATION

NOTE:

2"

3"

UP AND OVER BOX HOLES

SCH. 40 PVC NIPPLE

3/4" ROCK, 3 CUBIC FT.

LANDSCAPE FABRIC, WRAP

4 REQ PER BOX

BALL VALVE USING TWO

FINISHED GRADE

TRANSITION UP AND DOWN

IN SHRUB AREAS

BRICK SUPPORTS

2"

SECTION VIEW - N.T.S.

SCH. 80 PVC UNION

SCH. 40 PVC T.O.E. NIPPLE

LENGTH AS REQ., TYPICAL

SCH. 80 PVC 45 DEGREE

TO MAINLINE DEPTH FOR

1/2"

PVC MAINLINE PIPE, SEE

SEE NOTE BELOW.

ELLS, BOTH SIDES OF

BALL VALVE

FLOW

PURPLE PLASTIC ROUND VALVE BOX WITH BOLT DOWN COVER

W/STAINLESS STEEL BOLT, NUT AND WASHER. HEAT BRAND

COVER TO READ: "RECYCLED WATER-DO NOT DRINK" IN

ENGLISH AND SPANISH.

PLASTIC LABEL ATTACHED

W/NYLON. LABEL TO READ:

"RECYCLED WATER-DO NOT

DRINK" IN ENGLISH AND

SPANISH.

PURPLE PVC MAINLINE AND

SCH. 80 SLIP TEE, LABELLED

"RECYCLED WATER-DO NOT

DRINK".

USE A NON-HARDENING TEFLON PIPE SEALANT ON ALL THREADED CONNECTIONS.

AREA WITHOUT OVERSPRAY ONTO PAVING, FENCES, WALLS OR BUILDINGS.

INSTALL SPRINKLER HEADS PLUMB. ADJUST NOZZLE STREAM TO COVER LANDSCAPE

INSTALL SPRINKLER HEADS 4" FROM PAVING EDGE IN TURF AREAS.

MARLEX STREET ELL, 2 REQUIRED

SCH. 40 PVC THREADED ELL

SCH. 80 PVC NIPPLE, 8" LONG

SCH. 80 PVC NIPPLE, LENGTH AS REQUIRED

ABOVE FINISHED GRADE IN SHRUB

CONTRACTOR ASSEMBLED SWING JOINT SHALL BE SIZED TO MATCH THE SPRINKLER INLET.

INSTALL SPRINKLER HEADS 6" FROM PAVING EDGE IN GROUND COVER AREAS.

POP-UP SPRINKLER, SPRAY OR BUBBLER TYPE

SEE LEGEND FOR SPECIFICATION

INSTALL PURPLE PLASTIC POP-UP SPRAY SPRINKLER

FLUSH W/FINISHED GRADE IN TURF AREAS

1/2"

NOTE:

SCH. 40 PVC SxSxT TEE FITTING

LATERAL x SPRINKLER INLET SIZE

INSTALL SPRINKLER HEAD 1/2"

AND GROUND COVERS AREAS

NATIVE OR AMENDED SOIL

PA 80 ADAPTER FOR PCT NOZZLES

PURPLE PVC LATERAL LINE W/WORDS:

"RECYCLED WATER-DO NOT DRINK".

PURPLE PVC LATERAL LINE W/WORDS:

"RECYCLED WATER-DO NOT DRINK".

SUMMARY OF PROJECT WATER USE

FOR PLAYFIELD AREA ONLY

ESTIMATED EXISTING WATER DEMAND:

3,178,240 GAL ANNUALLY

ESTIMATED REMOVED WATER DEMAND:

536,461 GAL ANNUALLY

ESTIMATED PROPOSED WATER DEMAND:

459,550 GAL ANNUALLY

IRRI

GATI

ON D

ETAI

LS

TYPICAL PIPE TRENCH/FOOTING DETAIL

FOR ADDITIONAL PIPE TRENCH TO FOOTING DETAILS REFER

TO SHEET S0.3

DSAD E P A R T M E N T O F G E N E R A L S E R V I C E S

DIVISION OF THE STATE ARCHITECTDSADIVISION OF THE STATE ARCHITECTDSADIVISION OF THE STATE ARCHITECTDSADIVISION OF THE STATE ARCHITECT

IDENTIFICATION STAMP DIV. OF THE STATE ARCHITECT

APP: INC:REVIEWED FOR

SS FLS ACS

DATE:

✔ ✔ ✔

03-121157

07/19/2021

RD

Gate

Ramp

x

x

x

x

x

xx

(E) MAIN ADMIN. BUILDINGA#39042

(E) RELOCATABLES

FUN CLUB

A#107278

(E) RELOCATABLES

(E) SHADE

STRUCTURE

(E) RELOCATABLES

CHILDCARE

(E) ACCESSIBLE RAMPA#103962

(E) RELOCATABLESKINDERGARTEN

A#107278

(E) RELOCATABLESKINDERGARTEN

A#107278

(E) RELOCATABLESKINDERGARTEN

A#103962

(E) RELOCATABLESKINDERGARTEN

A#103962

(E) RELOCATABLES

CHILDCARE

P.A

P.A

P.A

P.A

(N) PLAY AREA

BASEBALLBACKSTOP

P.A

4'-0" HIGH W/ FENCEGUARD PROTECTIVECOVER

(E) SHADE

STRUCTURE

RD

Gate

Ramp

x

x

x

x

x

x

xx

x

x

x

x

x

H

Y

D

x

x

x

x

x

x

x

x

x

x

x

x

xx

x

xx

xx

x

x

x

x

x

x

x

x

x

x

x

x

x

x

*

*

**

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

**

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

*

WUCOLS 4: LOW

3' TALL/3' WIDE

SUN/PART SUN

WUCOLS 4: LOW

30" TALL/6' WIDE

SUN

ALL PLANTER AREAS WITH SHRUBS TO RECEIVE AN APPROVED

3" DEEP LAYER OF A REDWOOD OR CEDAR BARK MULCH OR

SHREDDED REDWOOD MULCH. TOP OF MUCH TO BE FLUSH

WITH TOP OF ADJACENT PAVING.

4" LAYER OF ORGANIC LOCK DECOMPOSED GRANITE BY

GAIL MATERIALS OVER 90% COMPACTED SUB-GRADE.

LOMANDRA LONGIFOLIA

'NYALLA'

5-GAL.

LANTANA CAMARA

"SUNBURST"

5-GAL.

WUCOLS 4 : LOW

18" TALL/42" WIDE

PART SUN/SHADE

MAHONIA AQUIFOLIUM

'COMPACTA'

5-GAL.

WUCOLS 4: LOW/MED

24" TALL/24" WIDE

SUN

HELICTOTRICHON SEMPER.

BLUE OAT GRASS

5-GAL.

WUCOLS 4: LOW

30" TALL/30" WIDE

SUN/PART SHADE

FESTUCA CALIFORNICA

'RIVER HOUSE BLUES'

1-GAL.

WUCOLS 4: MED/LOW

8" TALL/SPREADING

SUN/SHADE

FESTUCA RUBRA

"MOLATE"

SEEDED @ 12-LBS/1,000 SF

WUCOLS 4: LOW

16' TALL/12' WIDE

SUN'PART SHADE

CORDYLINE AUSTRALIS

'RED STAR'

24" BOX

WUCOLS 4: MED

50' TALL/30' WIDE

SUN

PLATANUS RACEMOSA

CALIFORNIA SYCAMORE

12 @ 36" BOX

WUCOLS 4: MED

30" TALL/30" WIDE

SUN

DIETES VEGETA

'VARIEGATA'

1-GAL.

24" BOX

WUCOLS 4: MED

50' TALL/30' WIDE

SUN

RHAPHIOLEPIS SP.

'MAJESTIC BEAUTY'

36" BOX

WUCOLS 4: MED

30' TALL/30' WIDE

SUN

PISTACHE CHINENSIS

CHINESE PISTACIA

36" BOX

*

0 8 16 32

PROJ

ECT

NUMB

ER:

DATE

:RE

VISI

ON:

DESC

RIPT

ION:

PROJ

ECT

STAT

US:

PROJ

ECT

ISSU

ED:

© 20

19 S

GH A

RCHI

TECT

S IN

C. A

LL R

IGHT

S RE

SERV

ED

SEAL

S:CO

NSUL

TANT

:19-47101-00

NEW

MUL

TIPU

RPOS

E &

CLAS

SROO

M BU

ILDIN

G

841 G

LE

NW

IC

K A

VE

., W

ALN

UT

, C

A91789

WA

LN

UT

E

LE

ME

NT

AR

Y S

CH

OO

L

WA

LN

UT

V

ALLE

Y U

SD

100%

C

D

12/10/20

SCALE:LANDSCAPE PLAN

silver bar studio

landscape architecture

environmental design

mariposa, ca.

2903

JULY 2022

PLAN

TING

PLA

N

L2.01

SUBGRADE PER STRUCTURAL

UNDISTURBED OR RECOMPACTED

SOILS REPORT.

2X ROOT BALL

MATERIAL, REFER TO LEGEND

WIDTH OF ROOTBALL

SOIL BERM, 3" HIGH

APPROVED CONTAINER PLANT

APPROVED BACKFILL MIX,

PLANT PIT, SHALL BE 2X

COMPACT TO 90% MIN.

1x R

OO

TB

AL

L

DE

PT

H

2"

B. TREE PLANTING

WIDTH OF ROOTBALL

(WHERE NOTED ON PLAN)

STAKE LENGTH AS REQ'D.

NOTE: 36" BOX AND SMALLER

PER LEGEND

NATURAL SOIL

BURY STAKE 18" MIN. INTO

LODGEPOLE PINE (2 REQ'D)

LINEAR DEEP ROOT BARRIER

APPROVED BACKFILL MIX,

PLANT PIT, SHALL BE 3X

COMPACT TO 90% MIN.

UNDISTURBED OR RECOMPACTED

SUBGRADE.

APPROVED CONTAINER TREE

TREE V.I.T. TWIST BRACES, 2 REQ'D.

SHALL BE STAKED.

1x R

OO

TB

AL

L

18

"4

"

MIN

.

DE

PT

H

3X ROOT BALL

WIDTH

4" M

AX

.

PLANT TABLETS: SIMPLOT BEST

PAKS 20-10-5 @ MANUFACTURER'S

APPLICATION RATES.

PLANT TABLETS: SIMPLOT BEST

PAKS 20-10-5 @ MANUFACTURER'S

APPLICATION RATES.

SET ROOTBALL 1"-2" ABOVE FINISH

GRADE AT SOIL BERM. SLOPE

BACKFILL TOWARDS BASE OF SOIL

BERM-AWAY FROM ROOTBALL.

2" M

AX

.

FINISH GRADE/TOP OF SOIL.

MULCH IS IN ADDITION.

FINISH GRADE/TOP OF SOIL.

MULCH IS IN ADDITION.

A. SHRUB PLANTING

SET ROOTBALL 1"-2" ABOVE FINISH

GRADE AT SOIL BERM. SLOPE

BACKFILL TOWARDS BASE OF SOIL

BERM-AWAY FROM ROOTBALL.

3" H

IG

H S

OIL

B

ER

M

3" H

IG

H S

OIL

B

ER

M

DSAD E P A R T M E N T O F G E N E R A L S E R V I C E S

DIVISION OF THE STATE ARCHITECTDSADIVISION OF THE STATE ARCHITECTDSADIVISION OF THE STATE ARCHITECTDSADIVISION OF THE STATE ARCHITECT

IDENTIFICATION STAMP DIV. OF THE STATE ARCHITECT

APP: INC:REVIEWED FOR

SS FLS ACS

DATE:

✔ ✔ ✔

03-121157

07/19/2021


Recommended