Deploying 400Gbit/s on the Janet network Rob Evans, Chief Network Architect
Transcript
Page 1: Deploying 400Gbit/s on the Janet network

Deploying 400Gbit/s on the Janet networkRob Evans, Chief Network Architect

Page 2: Deploying 400Gbit/s on the Janet network

What is Janet?

Deploying 400Gbit/s on the Janet network2

•National network for research and education

•Connects Higher and Further Education sites

•High speed connections to GÉANT, which connects all European R&E networks•…and on to other global NRENs

•”Everyday” use, students on their phones connected to wifi, through to large data flows from, e.g., the Large Hadron Collider, Bioinformatics, etc

•The question that everybody asks:•Jisc is the company •Janet is the network•Neither are acronyms any longer

Page 3: Deploying 400Gbit/s on the Janet network

What is Janet?

Deploying 400Gbit/s on the Janet network3

•Leased fibre from SSET

•Ciena 6500 transmission equipment managed in-house

•Predominantly Juniper routing base•MX2010•MX960

•Current network has been in service since 2013

•Fibre contract until 2028

•Previously regional aggregation networks managed autonomously

•Now all managed in-house•Process of rolling out new aggregation architecture to them all at the moment•Except Wales and Kent, which have all-sector public service aggregation networks

Page 4: Deploying 400Gbit/s on the Janet network

The Janet network – before.

Deploying 400Gbit/s on the Janet network4

Page 5: Deploying 400Gbit/s on the Janet network

The Janet network – the plan.

Deploying 400Gbit/s on the Janet network5

Page 6: Deploying 400Gbit/s on the Janet network

Why did we want/need 400G?

Deploying 400Gbit/s on the Janet network6

•Ever-increasing capacity demands• Incoming IP traffic to Janet from GEANT, peering, and transit is > 600Gbit/s

•More efficient spectrum usage

•Save on chassis space!•4x100G client plus 400G line in single slot, saves 3 slots compared to OTR (one slot per 100G), saves 7 slots (half a chassis) compared to OCI+OCLD (two slots per 100G).

•Flexgrid 9:1 WSS are two slots, older fixed grid 9:1 WSS occupied 3

Page 7: Deploying 400Gbit/s on the Janet network

Where should we deploy 400G?

7

•You might have thought where we wanted 600G•Busiest parts of the network•Lots of disruption to migrate from fixed grid to flexgrid.•Some routes too long to run Wavelogic Ai cards at 400G in 75GHz.• Other Wavelogic cards are available…

•Birmingham – Manchester – Leeds – Nottingham•Require 400G capacity•Replace existing 100G cards and re-deploy for South upgrade from 400G to 600G.

Page 8: Deploying 400Gbit/s on the Janet network

Will it work?

Deploying 400Gbit/s on the Janet network8

•100G transmission uses DP-QPSK encoding•Two polarisations, quadrature phase shifting

•Wavelogic Ai chipset adjusts encoding depending on OSNR•The better the OSNR, the more capacity•Proprietary modulation formats based on QPSK/8QAM/16QAM/32QAM/64QAM

•Step 1: Know what we’ve got•Original OTDR results now six years old•Take backbone fibres out of service to re-measure

Page 9: Deploying 400Gbit/s on the Janet network

OSNR: Why and how?

Deploying 400Gbit/s on the Janet network9

•Change from EDFA-based amplifiers to Raman•Strict loss requirements in the first 20km of fibre•Raman amplifiers include OTDR to check fibre is in spec before enabling

•Modelling on the planned spans•Good to go on Birmingham to Manchester and Nottingham to Leeds (& vice versa)•Manchester to Leeds: -0.42dB•Leeds to Manchester: -0.09dB•Anything below -0.3dB is out of spec•Conservative stance is that we can only do 300G between Leeds and Manchester

Page 10: Deploying 400Gbit/s on the Janet network

How does the fibre get from the road to the rack?

Deploying 400Gbit/s on the Janet network10

•Equinix MA1

Equinix Manchester

Incoming fibreEquinix

‘meet me’ rack

(basement)

Equinix ‘meet me’

rack(4th floor)

Janet optical

equipment rack

patch patch patch patchSupplier ‘meet me’

rack

Janet patching

rack

•Just splice the thing…• Spot the deliberate mistake in the diagram...

Page 11: Deploying 400Gbit/s on the Janet network

Flexgrid and colourless add/drop

Deploying 400Gbit/s on the Janet network11

•Existing WSSs all 50GHz fixed grid with wavelength-specific add/drop mux/demux (CMD44)

•400Gbit/s uses 56Gbaud in 75GHz

•‘Simple’ matter of replacing fixed-grid WSSs with flex-grid and introducing colourless add/drop.

Page 12: Deploying 400Gbit/s on the Janet network

Flexgrid conversion

Deploying 400Gbit/s on the Janet network12

Page 13: Deploying 400Gbit/s on the Janet network

Not quite colourless

Deploying 400Gbit/s on the Janet network13

OSC SFP 0-34dB Low TxPEC: NTK592NG

Loc: Shelf:3 Slot:14.2

Out

In

Line A In Line A OutA

Line B OutB

Line B In

LCLC6

7

5

8

6500 MLA2PEC: NTK552FA

Loc: Shelf: 3 Slot: 10

Line B Mon

Line A Mon

LC

2

1

OSC B In

OSC A Out

3

4

LC

6500

WS

S 50 G

Hz w

/OP

M 1x9

LC

LC

LC

6500 WSS 50 GHz 1x9PEC: NTK553FA

Shelf: 3 Slot: 11

LCLC

OPMMonitor 2

1

2

Monitor 1LC

LC

LC

LC

LC

LC

Common In

Common Out

21

22

Switch1 Out

Switch1 In

4

3

Swi tch3 Out

Switch3 In

8

7

Swi tch4 Out

Switch4 In

10

9

Switch5 Out12

Switch5 In11

Swi tch6 Out14

Switch6 In13

Swi tch7 Out16

Switch7 In15

Swi tch8 Out18

Switch8 In17

Swi tch9 Out20

Switch9 In19

Switch2 Out

Switch2 In

6

5

12 dB 12

Out

In

SC

To:U

nn

w_

man

ch

NE

219

7-1

-1

Line A In Line A OutA

Line B OutB

Line B In

LCLC

6

7

5

8

6500 MLAPEC: NTK552BA

Loc: Shelf: 1 Slot: 10

Line B Mon

Line A Mon

LC

2

1

OSC B In

OSC A Out

3

4

LC

6500

WS

S 5

0 GH

z w/O

PM

1x9

LC

LC

LC

6500 WSS 50 GHz 1x9PEC: NTK553FA

Shelf: 1 Slot: 11

LCLC

OPMMonitor 2

1

2

Monitor 1LC

LC

LC

LC

LC

LC

Common In

Common Out

21

22

Swi tch1 Out

Switch1 In

4

3

Swi tch3 Out

Switch3 In

8

7

Swi tch4 Out

Swi tch4 In

10

9

Switch5 Out12

Swi tch5 In11

Swi tch6 Out14

Swi tch6 In13

Swi tch7 Out16

Switch7 In15

Swi tch8 Out18

Swi tch8 In17

Swi tch9 Out20

Switch9 In19

Switch2 Out

Swi tch2 In

6

5

BMD2PEC: NTT862DA

Loc: Shelf:1 Slot:83

CommonOut

1Common

In

2

Input 1

Output 14

3

Input 2

Output 26

5

eCMD44 50GHz Red C-Band with TAPPEC: NTT862BD Shelf: 1 Slot: 85

89

90

92

6 dB1 2

OSC SFP 0-34dB Low TxPEC: NTK592NG

Loc: Shelf:1 Slot:14.1

Out

In

Line A InLine A OutA

Line B OutB

Line B In

LC LC

6

7

5

8

6500 MLA2PEC: NTK552FA

Loc: Shelf: 1 Slot: 9

Line B Mon

Line A Mon

LC

2

1

OSC B In

OSC A Out

3

4

LC

6500

WS

S 5

0 G

Hz

w/O

PM

1x9

LC

LC

LC

6500 WSS 50 GHz 1x9PEC: NTK553FA

Shelf: 1 Slot: 6

LCLC

OPMMonitor 2

1

2

Monitor 1LC

LC

LC

LC

LC

LC

Common In

Common Out

21

22

Switch1 Out

Switch1 In

4

3

Swi tch3 Out

Switch3 In

8

7

Swi tch4 Out

Switch4 In

10

9

Switch5 Out12

Switch5 In11

Swi tch6 Out14

Switch6 In13

Swi tch7 Out16

Switch7 In15

Swi tch8 Out18

Switch8 In17

Swi tch9 Out20

Switch9 In19

Switch2 Out

Swi tch2 In

6

5

Out

In

SC

To:A

ched

dle

NE

46

79-1

-2

OSC SFP 0-34dB Low TxPEC: NTK592NG

Loc: Shelf:2 Slot:14.1

Out

In

Line A InLine A OutA

Line B OutB

Line B In

LC LC

6

7

5

8

6500 MLA2PEC: NTK552FA

Loc: Shelf: 2 Slot: 9

Line B Mon

Line A Mon

LC

2

1

OSC B In

OSC A Out

3

4

LC

6500

WS

S 5

0 G

Hz

w/O

PM

1x9

LC

LC

LC

6500 WSS 50 GHz 1x9PEC: NTK553FA

Shelf: 2 Slot: 6

LCLC

OPMMonitor 2

1

2

Monitor 1LC

LC

LC

LC

LC

LC

Common In

Common Out

21

22

Switch1 Out

Switch1 In

4

3

Switch3 Out

Switch3 In

8

7

Switch4 Out

Swi tch4 In

10

9

Switch5 Out12

Swi tch5 In11

Switch6 Out14

Swi tch6 In13

Switch7 Out16

Switch7 In15

Switch8 Out18

Swi tch8 In17

Switch9 Out20

Switch9 In19

Swi tch2 Out

Switch2 In

6

5

Out

In

SC

To:S

outh

port

NE

227

9-4

-1

Line A InLine A OutA

Line B OutB

Line B In

LC LC6

7

5

8

6500 MLAPEC: NTK552BA

Loc: Shelf: 2 Slot: 10

Line B Mon

Line A Mon

LC

2

1

OSC B In

OSC A Out

3

4

LC

6500

WS

S 5

0 G

Hz

w/O

PM

1x9

LC

LC

LC

6500 WSS 50 GHz 1x9PEC: NTK553FA

Shelf: 2 Slot: 11

LCLC

OPMMonitor 2

1

2

Monitor 1LC

LC

LC

LC

LC

LC

Common In

Common Out

21

22

Switch1 Out

Switch1 In

4

3

Switch3 Out

Switch3 In

8

7

Switch4 Out

Switch4 In

10

9

Switch5 Out12

Switch5 In11

Switch6 Out14

Switch6 In13

Switch7 Out16

Switch7 In15

Switch8 Out18

Switch8 In17

Switch9 Out20

Switch9 In19

Swi tch2 Out

Switch2 In

6

5

BMD2PEC: NTT862DA

Loc: Shelf:2 Slot:83

CommonOut

1Common

In

2

Input 1

Output 14

3

Input 2

Output 26

5

eCMD44 50GHz Red C-Band with TAPPEC: NTT862BD Shelf: 2 Slot: 85

89

90

92

6 dB 12

6500

WS

S 5

0 GH

z w/O

PM

1x9

LC

LC

LC

6500 WSS 50 GHz 1x9PEC: NTK553FA

Shelf: 3 Slot: 6

LCLC

OPMMonit or 2

1

2

Monit or 1LC

LC

LC

LC

LC

LC

Common In

Common Out

21

22

Swi tch1 Out

Switch1 In

4

3

Switch3 Out

Switch3 In

8

7

Switch4 Out

Switch4 In

10

9

Switch5 Out12

Switch5 In11

Switch6 Out14

Switch6 In13

Switch7 Out16

Switch7 In15

Switch8 Out18

Switch8 In17

Switch9 Out20

Switch9 In19

Swi tch2 Out

Swi tch2 In

6

5

Line A In Line A OutA

Line B OutB

Line B In

LCLC

6

7

5

8

6500 MLA2PEC: NTK552FA

Loc: Shelf: 3 Slot: 9

Line B Mon

Line A Mon

LC

2

1

OSC B In

OSC A Out

3

4

LCOSC SFP 0-34dB Low Tx

PEC: NTK592NGLoc: Shelf:3 Slot:14.1

Out

In

Out

In

SC

To:Apre

son

NE

550

5-1-1

OSC SFP 0-34dB Low TxPEC: NTK592NG

Loc: Shelf:5 Slot:1.1

Out

In

Line A In Line A Out

Line B Out Line B In

LCLC

6

7

5

8

6500 MLA3PEC: NTK552GAE5

Loc: Shelf: 5 Slot: 5

Line B Mon

Line A Mon

LC

2

1

OSC B In

OSC A Out

3

4

LC

6500

WS

S 5

0 GH

z w/O

PM

1x9

LC

LC

LC

6500 WSS 50 GHz 1x9PEC: NTK553FA

Shelf: 5 Slot: 2

LCLC

OPMMonitor 2

1

2

Monitor 1LC

LC

LC

LC

LC

LC

Common In

Common Out

21

22

Swi tch1 Out

Switch1 In

4

3

Swi tch3 Out

Switch3 In

8

7

Swi tch4 Out

Swi tch4 In

10

9

Switch5 Out12

Swi tch5 In11

Swi tch6 Out14

Swi tch6 In13

Swi tch7 Out16

Switch7 In15

Swi tch8 Out18

Swi tch8 In17

Swi tch9 Out20

Switch9 In19

Switch2 Out

Swi tch2 In

6

5

Out

In

SC

To:D

ublin

NE

-1-2

PEC: NTK553FAShelf: 3 Slot: 3 OTS: 1DIA: True

9

10

OSC SFP 0-34dB Low TxPEC: NTK592NG

Loc: Shelf:4 Slot:14.1

Out

In

Line A InLine A Out A

Line B OutB

Line B In

LC LC

6

7

5

8

6500 MLAPEC: NTK552BA

Loc: Shelf: 4 Slot: 10

Line B Mon

Line A Mon

LC

2

1

OSC B In

OSC A Out

3

4

LC

6500

WS

S 5

0 G

Hz

w/O

PM

1x9

LC

LC

LC

6500 WSS 50 GHz 1x9PEC: NTK553FA

Shelf: 4 Slot: 11

LCLC

OPMMonit or 2

1

2

Monit or 1LC

LC

LC

LC

LC

LC

Common In

Common Out

21

22

Switch1 Out

Swi tch1 In

4

3

Switch3 Out

Swi tch3 In

8

7

Switch4 Out

Switch4 In

10

9

Swi tch5 Out12

Switch5 In11

Switch6 Out14

Switch6 In13

Switch7 Out16

Swi tch7 In15

Switch8 Out18

Switch8 In17

Switch9 Out20

Swi tch9 In19

Switch2 Out

Switch2 In

6

5

13 dB1 2

Out

In

SC

To:CP

LR_

TM

an

ch_

Wre

xN

E1

841

9-1

-1

WS

S 5

0G

Hz

w/O

PM

9x1

2-s

lot-

wid

e

LC

LC

LC

OME6500 WSSPEC: NTK553FC

Shelf: 7 Slot: 3

LCLC

OPMMonitor 2

1

2

Monitor 1LC

LC

LC

LC

LC

LC

Common In

Common Out

21

22

Swi tch1 Out

Switch1 In

4

3

Swi tch3 Out

Switch3 In

8

7

Swi tch4 Out

Swi tch4 In

10

9

Switch5 Out12

Swi tch5 In11

Swi tch6 Out14

Swi tch6 In13

Swi tch7 Out16

Switch7 In15

Switch8 Out Drop118

Switch8 In Add117

Swi tch9 Out Drop220

Switch9 In Add219

Switch2 Out

Switch2 In

6

5

Line B In Line B OutB

Line A OutA

Line A In

LCLC

8

5

7

6

MLA2PEC: NTK552FAE5

Loc: Shelf:7 Slot:2

Monitor 1

Monit or 2

LC

2

1

OSC B In

OSC A Out

3

4

LCOSC SFP 0-34dB Low Tx

PEC: NTK592NGLoc: Shelf:7 Slot:1.1

Out

In

In

Out

SC

To:J

od

rell B

ank

ma

ccjb-dm

x1-1

-1

CMD 6489

90

92

6500

WS

S 5

0 G

Hz

w/O

PM

1x9

LC

LC

LC

6500 WSS 50 GHz 1x9PEC: NTK553FA

Shelf: 1 Slot: 5

LCLC

OPMMonitor 2

1

2

Monitor 1LC

LC

LC

LC

LC

LC

Common In

Common Out

21

22

Switch1 Out

Switch1 In

4

3

Switch3 Out

Switch3 In

8

7

Switch4 Out

Switch4 In

10

9

Switch5 Out12

Switch5 In11

Switch6 Out14

Switch6 In13

Switch7 Out16

Switch7 In15

Switch8 Out18

Switch8 In17

Switch9 Out20

Switch9 In19

Switch2 Out

Switch2 In

6

5

Line A InLine A Out A

Line B OutLine B In

LC LC6

7

5

8

6500 SLAPEC: NTK552AA

Loc: Shelf: 1 Slot: 4

Line B Mon

Line A Mon

LC

2

1

OSC B In

OSC A Out

3

4

LC

Page 14: Deploying 400Gbit/s on the Janet network

If only it was that easy…

Deploying 400Gbit/s on the Janet network14

•Network-wide software upgrade beforehand•Not just one, but two: 10.2 -> 11.2 -> 12.1•OneControl

•Change in licensing approach for 12.1•License alarms after upgrade•Deploy external license server

•Different power calculations between releases of software•Existing services entered a “waiting for power” state after upgrade

Page 15: Deploying 400Gbit/s on the Janet network

It was all worth it in the end…

Deploying 400Gbit/s on the Janet network15

•Initially provisioned Manchester – Leeds with 3x100G clients•Wavelength came up at 400G•Able to add fourth service and run it at 400G

Page 16: Deploying 400Gbit/s on the Janet network

Where next?

Deploying 400Gbit/s on the Janet network16

•Migrating the rest of the network to flexgrid•Just completed

•Deploying true colourless add/drop•Next up

•Newer cards for the longer spans

•400GE clients•A whole other talk… on QSFP56-DD, etc

Page 17: Deploying 400Gbit/s on the Janet network

Questions?