DESIGN FOR DISABLE - TOILET DETAILS 1
DESIGN FOR DISABLE – TOILET DETAILSMUKUND SUTHAR & SAKSHAM GOYAL
05/03/2023DESIGN FOR DISABLE - TOILET DETAILS
2
AIMAS AN ARCHITECTOUR RESPONSIBILITY IS TO INTEGRATE DISABLE PEOPLE INTO THE SOCIETY IN ORDER FOR THEM TO TAKES AN ACTIVE PART IN SOCIETY AND LEAD A NORMAL LIFE. TO BE ACTIVE, A DISABLE PERSON SHOULD ABLE TO COMMUTT BETWEEN HOME, WORK AND OTHER DESTINATIONS THE TECHNICAL AIM OF THE PRESENTATON IS TO PROVIDE A BARRIER-FREE ENVIRONMENT FOR THE INDEPENDENCE, CONVENIENCE AND SAFETY OF ALL PEOPLE WITH DISABILITY.
IN THE PHYSICAL TERMS, THE PROVISIONAL OF A BARRIAER-FREE ENVIROMENT CAN BE THE UNDERSTAND IN FOUR COMPLEMENTARY DOMAIN :-INSIDE BUILDINGIN THE IMMEDIATE VICINITY OF BUILDINGSON THE LOCAL ROAD AND PATHSIN OPEN AREA AND RECREATIONAL AREAS.
05/03/2023DESIGN FOR DISABLE - TOILET DETAILS
3
SIGNAGES
05/03/2023DESIGN FOR DISABLE - TOILET DETAILS
4
SPACE REQUIREMENT
05/03/2023DESIGN FOR DISABLE - TOILET DETAILS
5
TOILET LAYOUTSOME POINTS TO REMEMBER :- THE MIN. SIZE SHALL BE 1500 X 1750 mm. TURNING CIRCLE OF 1500mm DIA ARE RECOMMENDED
INSIDE THE WASHROON TO ALLOW FOR FULL TURN MOVEMENT OF A WHEELCHAIR.
THE PARALLEL APPOACH, WHICH IS THE EASIEST. THE DIAGONAL
APPROACH. WHICH IS DIFFCULT
05/03/2023DESIGN FOR DISABLE - TOILET DETAILS
6
TOILET FLOOR SHALL HAVE A NON-SLI SURFACE WITHOUT ANY LVL. DIFFERECE.
GUIDING BLOCK NEAR THE ENTRY SHOULD BE HAVE A TEXTURAL DIFFERENCE, (E.G. DIAMON TILES, PRIMA REGINA TILES, UNDRESSED GRANITE).
LIGHT WEIGHT PVC DOOR SHUTTER SHOULD BE PROVIDED AS A SLIDING DOOR.
PROVISIONAL OF VERTICAL & HORZONTAL RAIL AS 40mm C.P. STEEL PIPE.
05/03/2023DESIGN FOR DISABLE - TOILET DETAILS
7
TOILET LAYOUT - 1
05/03/2023DESIGN FOR DISABLE - TOILET DETAILS
8
TOILET DETAIL – DOOR
05/03/2023DESIGN FOR DISABLE - TOILET DETAILS
9
TOILET DETAIL – HAND RAIL
05/03/2023DESIGN FOR DISABLE - TOILET DETAILS
10
TOILET DETAIL–WATERCLOSET(WC) FLUSH VALVE IS ON WIDE SIDE OF THE
ACCESSIBLR WATER CLOSET GRAB BARS REQUIRED
05/03/2023DESIGN FOR DISABLE - TOILET DETAILS
11
TOILET DETAIL–WATERCLOSET(WC)
HEIGHT OF ACCESSIBLE WATER CLOSET SHALL BE 430 – 485 mm MEASURED TO THE TOP OF THE TOILET SEAT.
05/03/2023DESIGN FOR DISABLE - TOILET DETAILS
12
TOILET DETAILS – SPACE & REACH SPACE ALLOWANCE & REACH RANGES MIN CLEAR WIDTH FOR WHEELCHAIR
PASSAGE – 800 – 1000 mm.
05/03/2023DESIGN FOR DISABLE - TOILET DETAILS
13
TOILET DETAILS–LAVATORIES&MIRRORS
Lavatories shall be mounted with the rim or counter surface no higher than 850mm above the finished floor Provide a clearance of at least 725mm above the finished floor to the bottom of the apron.
Clear floor space- 750mm X1200mm shall be provided in front of lavatory.
05/03/2023DESIGN FOR DISABLE - TOILET DETAILS
14
TOILET DETAILS–LAVATORIES&MIRRORS
05/03/2023DESIGN FOR DISABLE - TOILET DETAILS
15
Hot water and drain pipes under lavatories shall be insulated or otherwise configured to protect against contact.
TOILET DETAILS–LAVATORIES&MIRRORS
05/03/2023DESIGN FOR DISABLE - TOILET DETAILS
16
TOILET LAYOUT - 2 ACCESSIBLE TOILET AND SHOWER
COMPARTMENT
05/03/2023DESIGN FOR DISABLE - TOILET DETAILS
17
TOILET LAYOUT - 2 ACCESSIBLE TOILET AND SHOWER
COMPARTMENT