“Design Of The Ion Extraction System In A Reaction Microscope” Speaker: Marco Panniello Federico II University Industrial Engineering PhD School “Innovative Technologies For Materials, Sensors And Imaging” 1
Transcript
Page 1: “Design Of The Ion Extraction System In A Reaction Microscope” Speaker: Marco Panniello Federico II University Federico II University Industrial Engineering.

“Design Of The Ion Extraction

System In A Reaction Microscope”

Speaker:

Marco Panniello

Federico II UniversityIndustrial Engineering PhD School

“Innovative Technologies For Materials, Sensors And Imaging”

1

Page 2: “Design Of The Ion Extraction System In A Reaction Microscope” Speaker: Marco Panniello Federico II University Federico II University Industrial Engineering.

Federico II University Industrial Engineering PhD SchoolInnovative Technologies For Materials, Sensors And Imaging” Introduction

Federico II University Industrial Engineering PhD School

“Innovative Technologies For Materials, Sensors And Imaging”

Context:

Purpose:

Antiprotons Recycler ring for differential cross section measurements.

Design of a suitable geometry for the recoil ion extraction system.

Introduction

Development

Conclusions

2

Page 3: “Design Of The Ion Extraction System In A Reaction Microscope” Speaker: Marco Panniello Federico II University Federico II University Industrial Engineering.

Introduction

Development

- R.I.M.S.

- The Recycler

- Working Principles

- Geometry U.C.

- T.F.C.

- Homogeneously

- Catch & Resolve

- Resolution

- Suitable Geometry

Recoil Ion Momentum Spectroscopy

• high precision device

• more appropriate for coincidence measurements than energy or momentum dispersive spectrometers.

• Evolutions:

- COLTRIMS (Cold Target RIMS);

- Reaction Microscopes.

3

Conclusions

Page 4: “Design Of The Ion Extraction System In A Reaction Microscope” Speaker: Marco Panniello Federico II University Federico II University Industrial Engineering.

The Recycler• The projectile hits the target gas molecules generating

an atomic reaction. The most common effect is the target ionization

• The “recoil” ion is extracted from the collision area and accelerated toward a Time-Position sensible Detector. (MCP).

4

• The projectile type is antiproton, currently used for single pass experiments.

• A simple structure called recycler is able to use these antiprotons more than one time.

Conclusions

Introduction

Development

- R.I.M.S.

- The Recycler

- Working Principle

- Geometry U.C.

- T.F.C.

- Homogeneously

- Catch & Resolve

- Resolution

- Suitable Geometry

Page 5: “Design Of The Ion Extraction System In A Reaction Microscope” Speaker: Marco Panniello Federico II University Federico II University Industrial Engineering.

5

Geometry Under Consideration

Conclusions

A simple structure that grants the homogeneous field on Detector axis can be taken as a basic idea.

Introduction

Development

- R.I.M.S.

- The Recycler

- Working Principle

- Geometry U.C.

- T.F.C.

- Homogeneously

- Catch & Resolve

- Resolution

- Suitable Geometry

Page 6: “Design Of The Ion Extraction System In A Reaction Microscope” Speaker: Marco Panniello Federico II University Federico II University Industrial Engineering.

6

Time Focusing Condition

Conclusions

• In the real case we have not a point like volume source, so we have to take in account the consequent time jitter

Introduction

Development

- R.I.M.S.

- The Recycler

- Working Principle

- Geometry U.C.

- T.F.C.

- Homogeneously

- Catch & Resolve

- Resolution

- Suitable Geometry

ΔE/E=18%

Page 7: “Design Of The Ion Extraction System In A Reaction Microscope” Speaker: Marco Panniello Federico II University Federico II University Industrial Engineering.

7

Homogeneous Field

Conclusions

More difficult than you can expect…….Introduction

Development

- R.I.M.S.

- The Recycler

- Working Principle

- Geometry U.C.

- T.F.C.

- Homogeneously

- Catch & Resolve

- Resolution

- Suitable Geometry

ΔE/E=1.4%

ΔE/E=0.27%

Page 8: “Design Of The Ion Extraction System In A Reaction Microscope” Speaker: Marco Panniello Federico II University Federico II University Industrial Engineering.

8

Acceptance vs Resolution

Conclusions

• A good acceptance needs a strongest field

• A good resolution needs a weaker field

• All depend by ion type and Spectrometer geometry

Introduction

Development

- R.I.M.S.

- The Recycler

- Working Principle

- Geometry U.C.

- T.F.C.

- Homogeneously

- Catch & Resolve

- Resolution

- Suitable Geometry

Page 9: “Design Of The Ion Extraction System In A Reaction Microscope” Speaker: Marco Panniello Federico II University Federico II University Industrial Engineering.

9

spectrometer resolution limitations imposed by the detector

As example : 10V/10cm ;

Time resolution Δt = 1ns

= 0.01 a.u.

Position resolution Δr = 0.1mm

= 0.02 a.u.MqUda

rP

)2(6.11

ta

qUP 3// 10042.8

Resolution Considerations

Conclusions

Introduction

Development

- R.I.M.S.

- The Recycler

- Working Principle

- Geometry U.C.

- T.F.C.

- Homogeneously

- Catch & Resolve

- Resolution

- Suitable Geometry

Page 10: “Design Of The Ion Extraction System In A Reaction Microscope” Speaker: Marco Panniello Federico II University Federico II University Industrial Engineering.

Conclusions

10

Suitable Geometry

In addition we have problems depending on the spectrometer, in terms of dimension limitations.

Introduction

Development

- R.I.M.S.

- The Recycler

- Working Principle

- Geometry U.C.

- T.F.C.

- Homogeneously

- Catch & Resolve

- Resolution

- Suitable Geometry

ΔE/E=0.5%

Page 11: “Design Of The Ion Extraction System In A Reaction Microscope” Speaker: Marco Panniello Federico II University Federico II University Industrial Engineering.

Conclusions

Introduction

Development

- R.I.M.S.

- The Recycler

- Working Principle

- Geometry U.C.

- T.F.C.

- Homogeneously

- Catch & Resolve

- Resolution

- Suitable Geometry

Conclusions

11

Federico II University Industrial Engineering PhD SchoolInnovative Technologies For Materials, Sensors And Imaging”

After several simulation I reached a geometryWith these properties:

Length of acceleration region a = 7 cm

Potential U = 7 V

Maximum Transverse Momentum P = 8.7 a.u.It guarantee an Acceptance of 4π

Transverse momentum resolution0.02 a.u.

Longitudinal Momentum Resolution0.01 a.u.

Page 12: “Design Of The Ion Extraction System In A Reaction Microscope” Speaker: Marco Panniello Federico II University Federico II University Industrial Engineering.

Grazie per

l’attenzioneMarco Panniello

END

12

“You do not really understand something until you can explain it to

your grandmother”

Albert Einstein

Federico II University Industrial Engineering PhD SchoolInnovative Technologies For Materials, Sensors And Imaging”

Page 13: “Design Of The Ion Extraction System In A Reaction Microscope” Speaker: Marco Panniello Federico II University Federico II University Industrial Engineering.

Conclusions

13

A Look Forward

Introduction

Development

- R.I.M.S.

- The Recycler

- Working Principle

- R.I.M.S. Theory

- P// Reconstruction

- T. F. Condition

- P† Reconstruction

- Resolution

- A Look Forward

• Detection of Recoil Ion only is not enough to characterize the reaction completely.

• Hence, it is “sufficient” to measure the momentum vectors of all target fragments.

• Since the reactions product usually consist of ions and electrons, it’s necessary a system to push them towards a detector.• The electron trajectories are easily modified by small

magnetic fields.

• It is possible to detect ions and electrons at the same time using both electric and magnetic fields