+ All Categories
Home > Documents > Developing a Testing Process for Remote Usage of Multimedia Messaging Centre

Developing a Testing Process for Remote Usage of Multimedia Messaging Centre

Date post: 01-Jan-2016
Category:
Upload: grady-norton
View: 24 times
Download: 0 times
Share this document with a friend
Description:
Developing a Testing Process for Remote Usage of Multimedia Messaging Centre. Master´s Thesis Presentation : 14-08-2007 Syed Ali Raza : 66196A. Acknowledgments. Professor Olav Tirkkonen Communications Laboratory Sami Leppänen Ericsson System Tester Jarko Mikonsaari - PowerPoint PPT Presentation
12
Developing a Testing Process for Remote Usage of Multimedia Messaging Centre Master´s Thesis Presentation : 14-08-2007 Syed Ali Raza : 66196A
Transcript

Slide titleIn CAPITALS

50 pt

Slide subtitle 32 pt

Developing a Testing Process for Remote Usage of

Multimedia Messaging Centre

Master´s Thesis Presentation : 14-08-2007

Syed Ali Raza : 66196A

Top right corner for field-mark, customer or partner logotypes. See Best practice for example.

Slide title 40 pt

Slide subtitle 24 pt

Text 24 pt

Bullets level 2-520 pt

© Ericsson AB 2006 13-12-20062

Acknowledgments

Professor Olav Tirkkonen– Communications Laboratory

Sami Leppänen– Ericsson System Tester

Jarko Mikonsaari– Ericsson System Tester

Top right corner for field-mark, customer or partner logotypes. See Best practice for example.

Slide title 40 pt

Slide subtitle 24 pt

Text 24 pt

Bullets level 2-520 pt

© Ericsson AB 2006 13-12-20063

Agenda

Thesis Background Methodology Adopted MultiMedia Messaging Center Remote Access Tools Experimental Setup Experimental results

Top right corner for field-mark, customer or partner logotypes. See Best practice for example.

Slide title 40 pt

Slide subtitle 24 pt

Text 24 pt

Bullets level 2-520 pt

© Ericsson AB 2006 13-12-20064

Thesis Background Global Service Delivery Centers - GSDCs

– System Test Plants (STPs)

Remote Usage: Remotely using any device, as here its MMC which can be accessed from a distance

Utilization of Resources Tools: Enhanced Service Portfolio Air Interface & Mobile Subscriber Simulator- AIMS User Guides

16-24hr 08-16hr 00-08hr

Top right corner for field-mark, customer or partner logotypes. See Best practice for example.

Slide title 40 pt

Slide subtitle 24 pt

Text 24 pt

Bullets level 2-520 pt

© Ericsson AB 2006 13-12-20065

Methodology

Top right corner for field-mark, customer or partner logotypes. See Best practice for example.

Slide title 40 pt

Slide subtitle 24 pt

Text 24 pt

Bullets level 2-520 pt

© Ericsson AB 2006 13-12-20066

MultiMedia Messaging Center

3GPP MMC Ericsson MMC Message Flow

Top right corner for field-mark, customer or partner logotypes. See Best practice for example.

Slide title 40 pt

Slide subtitle 24 pt

Text 24 pt

Bullets level 2-520 pt

© Ericsson AB 2006 13-12-20067

Remote Access

Ericsson Distributed Test Data Network-EDN Ericsson Corporate Network- ECN Ericsson Network Firewalls and Setup Proposed Firewall

Top right corner for field-mark, customer or partner logotypes. See Best practice for example.

Slide title 40 pt

Slide subtitle 24 pt

Text 24 pt

Bullets level 2-520 pt

© Ericsson AB 2006 13-12-20068

Tools Air Interface & Mobile Subscriber Simulator-AIMS

– Limitations by vendor– Hardware Customization(racks, terminals, power etc)– Software Bug– Scripting– Script Generation– Changes in Limitations

Java Traffic Tool Tactel, MMS diagnostic and Scripts

Top right corner for field-mark, customer or partner logotypes. See Best practice for example.

Slide title 40 pt

Slide subtitle 24 pt

Text 24 pt

Bullets level 2-520 pt

© Ericsson AB 2006 13-12-20069

Experimental Setup

Remote Setup

STP O&M

LMF

Per Wallenius (LMFPW)

PA1

ETH BSC Support setup - p1

Document No.

Title

Page

Prepared

Approved

Date

Rev

09-11-2006

Kari Bergström (EEDKGB)

1

FibreSerial

CopperCoax

Legend

SCSI

LMF-06:001493 Uen

Mobile Rack MR 3

MS1044101180034

BTS28

MS944101180033 MS12

44101180036

STP NetworkSGSN

Terminal ServerWIN2KTERM10

Win2kterm10.lmf.ericsson.se

ISP serverVIP: 192.168.2.nnnn = MS numberEg VIP for MS4 = 192.168.2.4

AIMS Serverspa8ws128

GGSN

ETHIP:________

Note: All connections to test nodes goes via Terminal server. There are predefined icons for all nodes and AIMS server.

MS1144101180035

BTS23

BSC13SP=2-13182APZ 212 30 IOG20 IP: 131.160.96.74 :2572 - 2587

SRS1

Mobile Rack MR 4

MS1344101180037

MS1444101180038

MS1544101180011

MSC18SP=2-1018

MS13-16

SMS +4422020000

Top right corner for field-mark, customer or partner logotypes. See Best practice for example.

Slide title 40 pt

Slide subtitle 24 pt

Text 24 pt

Bullets level 2-520 pt

© Ericsson AB 2006 13-12-200610

Experimental Results

Traffic Generation Interface Monitoring Troubleshooting

Top right corner for field-mark, customer or partner logotypes. See Best practice for example.

Slide title 40 pt

Slide subtitle 24 pt

Text 24 pt

Bullets level 2-520 pt

© Ericsson AB 2006 13-12-200611

Conclusions and future work

A Process for remotely accessing MMC is developed Training tools for customers (AIMS, Java Test Tool,

Tactel, etc.) AIMS is fixed for MMS usage. Java Traffic Tool is developed

Interference Shielding of AIMS Load Testing Tools should be used Deeper understanding of tools usage Additional tools for service Portfolio of MMS

Top right corner for field-mark, customer or partner logotypes. See Best practice for example.

Slide title 40 pt

Slide subtitle 24 pt

Text 24 pt

Bullets level 2-520 pt

© Ericsson AB 2006 13-12-200612


Recommended