Development of measurement procedure for the application of magnetic nanoparticles in surgery Datz Dániel Tutor: Antal Gasparics PhD Pázmány Péter Catholic University Faculty of Information Technology
Transcript
Page 1: Development of measurement procedure for the application of magnetic nanoparticles in surgery Datz Dániel Tutor: Antal Gasparics PhD Pázmány Péter Catholic.

Development of measurement procedure for the application of magnetic nanoparticles in

surgery

Datz DánielTutor: Antal Gasparics PhD

Pázmány Péter Catholic UniversityFaculty of Information Technology

Page 2: Development of measurement procedure for the application of magnetic nanoparticles in surgery Datz Dániel Tutor: Antal Gasparics PhD Pázmány Péter Catholic.

Radiopharmaceuticals

Page 3: Development of measurement procedure for the application of magnetic nanoparticles in surgery Datz Dániel Tutor: Antal Gasparics PhD Pázmány Péter Catholic.

NANOMAGDYE: The marker

• Phosphonate coupling agent stabilizes pH at 4.7 -> blood.• Simple experiment for biocompatibility• Synthesis with microbubbles -> ultrasound

contranst agent

Page 4: Development of measurement procedure for the application of magnetic nanoparticles in surgery Datz Dániel Tutor: Antal Gasparics PhD Pázmány Péter Catholic.

NANOMAGDYE: The probe• Magnetic and optical sensor built together• Fluxset sensor: soft magnetic core, two coils: driving and pickup coil

• No intrinsic magnetic field: excited with a third coil: excitation coil• Nanoparticles need very strong excitation: differential excitation

Page 5: Development of measurement procedure for the application of magnetic nanoparticles in surgery Datz Dániel Tutor: Antal Gasparics PhD Pázmány Péter Catholic.

Measurements on low velocities

Page 6: Development of measurement procedure for the application of magnetic nanoparticles in surgery Datz Dániel Tutor: Antal Gasparics PhD Pázmány Péter Catholic.

Measurements on hand movement speed

Page 7: Development of measurement procedure for the application of magnetic nanoparticles in surgery Datz Dániel Tutor: Antal Gasparics PhD Pázmány Péter Catholic.

Conclusion• At low velocities there are no significant distorting effects• At higher velocities the distorting effects are at most 10-15% of the maximum

amplitude

• The probe is completely capable of the measurements it was designed to do

• Simulation of the measurements• Algorithm for signal source localization

E-mail: [email protected]

Thank you for your attention!