+ All Categories
Home > Documents > DFEC30 - P-DUKE Characteristic...DFEC30 Application Note: Characteristic Curves 11/17/2016 P-DUKE...

DFEC30 - P-DUKE Characteristic...DFEC30 Application Note: Characteristic Curves 11/17/2016 P-DUKE...

Date post: 16-Aug-2020
Category:
Upload: others
View: 2 times
Download: 0 times
Share this document with a friend
48
DFEC30 Application Note: Characteristic Curves 11/17/2016 P-DUKE TECHNOLOGY CO., LTD. www.pduke.com 1 Characteristic Curves All test conditions are at 25.The figures are identical for DFEC30-12D12 Efficiency versus Output Load Power Dissipation versus Output Load Efficiency versus Input Voltage Derating Output Load versus Ambient Temperature and Airflow Vin(nom)
Transcript
Page 1: DFEC30 - P-DUKE Characteristic...DFEC30 Application Note: Characteristic Curves 11/17/2016 P-DUKE TECHNOLOGY CO., LTD. 3 Characteristic Curves (Continued) All test conditions are at

DFEC30Application Note: Characteristic Curves

11/17/2016

P-DUKE TECHNOLOGY CO., LTD.

www.pduke.com 1

Characteristic Curves All test conditions are at 25℃.The figures are identical for DFEC30-12D12

Efficiency versus Output Load Power Dissipation versus Output Load

Efficiency versus Input Voltage Derating Output Load versus Ambient Temperature and Airflow

Vin(nom)

Page 2: DFEC30 - P-DUKE Characteristic...DFEC30 Application Note: Characteristic Curves 11/17/2016 P-DUKE TECHNOLOGY CO., LTD. 3 Characteristic Curves (Continued) All test conditions are at

DFEC30Application Note: Characteristic Curves

11/17/2016

P-DUKE TECHNOLOGY CO., LTD.

www.pduke.com 2

Characteristic Curves (Continued) All test conditions are at 25℃.The figures are identical for DFEC30-12D12

Typical Output Ripple and Noise. Transient Response to Dynamic Load Change from

Vin(nom); Full Load 100% to 75% to 100% of Full Load; Vin(nom)

Typical Input Start-Up and Output Rise Characteristic Using ON/OFF Voltage Start-Up and Output Rise Characteristic

Vin(nom); Full Load Vin(nom); Full Load

Page 3: DFEC30 - P-DUKE Characteristic...DFEC30 Application Note: Characteristic Curves 11/17/2016 P-DUKE TECHNOLOGY CO., LTD. 3 Characteristic Curves (Continued) All test conditions are at

DFEC30Application Note: Characteristic Curves

11/17/2016

P-DUKE TECHNOLOGY CO., LTD.

www.pduke.com 3

Characteristic Curves (Continued) All test conditions are at 25℃.The figures are identical for DFEC30-12D15

Efficiency versus Output Load Power Dissipation versus Output Load

Efficiency versus Input Voltage Derating Output Load versus Ambient Temperature and Airflow

Vin(nom)

Page 4: DFEC30 - P-DUKE Characteristic...DFEC30 Application Note: Characteristic Curves 11/17/2016 P-DUKE TECHNOLOGY CO., LTD. 3 Characteristic Curves (Continued) All test conditions are at

DFEC30Application Note: Characteristic Curves

11/17/2016

P-DUKE TECHNOLOGY CO., LTD.

www.pduke.com 4

Characteristic Curves (Continued) All test conditions are at 25℃.The figures are identical for DFEC30-12D15

Typical Output Ripple and Noise. Transient Response to Dynamic Load Change from

Vin(nom); Full Load 100% to 75% to 100% of Full Load; Vin(nom)

Typical Input Start-Up and Output Rise Characteristic Using ON/OFF Voltage Start-Up and Output Rise Characteristic

Vin(nom); Full Load Vin(nom); Full Load

Page 5: DFEC30 - P-DUKE Characteristic...DFEC30 Application Note: Characteristic Curves 11/17/2016 P-DUKE TECHNOLOGY CO., LTD. 3 Characteristic Curves (Continued) All test conditions are at

DFEC30Application Note: Characteristic Curves

11/17/2016

P-DUKE TECHNOLOGY CO., LTD.

www.pduke.com 5

Characteristic Curves (Continued) All test conditions are at 25℃.The figures are identical for DFEC30-24D12

Efficiency versus Output Load Power Dissipation versus Output Load

Efficiency versus Input Voltage Derating Output Load versus Ambient Temperature and Airflow

Vin(nom)

Page 6: DFEC30 - P-DUKE Characteristic...DFEC30 Application Note: Characteristic Curves 11/17/2016 P-DUKE TECHNOLOGY CO., LTD. 3 Characteristic Curves (Continued) All test conditions are at

DFEC30Application Note: Characteristic Curves

11/17/2016

P-DUKE TECHNOLOGY CO., LTD.

www.pduke.com 6

Characteristic Curves (Continued) All test conditions are at 25℃.The figures are identical for DFEC30-24D12

Typical Output Ripple and Noise. Transient Response to Dynamic Load Change from

Vin(nom); Full Load 100% to 75% to 100% of Full Load; Vin(nom)

Typical Input Start-Up and Output Rise Characteristic Using ON/OFF Voltage Start-Up and Output Rise Characteristic

Vin(nom); Full Load Vin(nom); Full Load

Page 7: DFEC30 - P-DUKE Characteristic...DFEC30 Application Note: Characteristic Curves 11/17/2016 P-DUKE TECHNOLOGY CO., LTD. 3 Characteristic Curves (Continued) All test conditions are at

DFEC30Application Note: Characteristic Curves

11/17/2016

P-DUKE TECHNOLOGY CO., LTD.

www.pduke.com 7

Characteristic Curves (Continued) All test conditions are at 25℃.The figures are identical for DFEC30-24D15

Efficiency versus Output Load Power Dissipation versus Output Load

Efficiency versus Input Voltage Derating Output Load versus Ambient Temperature and Airflow

Vin(nom)

Page 8: DFEC30 - P-DUKE Characteristic...DFEC30 Application Note: Characteristic Curves 11/17/2016 P-DUKE TECHNOLOGY CO., LTD. 3 Characteristic Curves (Continued) All test conditions are at

DFEC30Application Note: Characteristic Curves

11/17/2016

P-DUKE TECHNOLOGY CO., LTD.

www.pduke.com 8

Characteristic Curves (Continued) All test conditions are at 25℃.The figures are identical for DFEC30-24D15

Typical Output Ripple and Noise. Transient Response to Dynamic Load Change from

Vin(nom); Full Load 100% to 75% to 100% of Full Load; Vin(nom)

Typical Input Start-Up and Output Rise Characteristic Using ON/OFF Voltage Start-Up and Output Rise Characteristic

Vin(nom); Full Load Vin(nom); Full Load

Page 9: DFEC30 - P-DUKE Characteristic...DFEC30 Application Note: Characteristic Curves 11/17/2016 P-DUKE TECHNOLOGY CO., LTD. 3 Characteristic Curves (Continued) All test conditions are at

DFEC30Application Note: Characteristic Curves

11/17/2016

P-DUKE TECHNOLOGY CO., LTD.

www.pduke.com 9

Characteristic Curves (Continued) All test conditions are at 25℃.The figures are identical for DFEC30-48D12

Efficiency versus Output Load Power Dissipation versus Output Load

Efficiency versus Input Voltage Derating Output Load versus Ambient Temperature and Airflow

Vin(nom)

Page 10: DFEC30 - P-DUKE Characteristic...DFEC30 Application Note: Characteristic Curves 11/17/2016 P-DUKE TECHNOLOGY CO., LTD. 3 Characteristic Curves (Continued) All test conditions are at

DFEC30Application Note: Characteristic Curves

11/17/2016

P-DUKE TECHNOLOGY CO., LTD.

www.pduke.com 10

Characteristic Curves (Continued) All test conditions are at 25℃.The figures are identical for DFEC30-48D12

Typical Output Ripple and Noise. Transient Response to Dynamic Load Change from

Vin(nom); Full Load 100% to 75% to 100% of Full Load; Vin(nom)

Typical Input Start-Up and Output Rise Characteristic Using ON/OFF Voltage Start-Up and Output Rise Characteristic

Vin(nom); Full Load Vin(nom); Full Load

Page 11: DFEC30 - P-DUKE Characteristic...DFEC30 Application Note: Characteristic Curves 11/17/2016 P-DUKE TECHNOLOGY CO., LTD. 3 Characteristic Curves (Continued) All test conditions are at

DFEC30Application Note: Characteristic Curves

11/17/2016

P-DUKE TECHNOLOGY CO., LTD.

www.pduke.com 11

Characteristic Curves (Continued) All test conditions are at 25℃.The figures are identical for DFEC30-48D15

Efficiency versus Output Load Power Dissipation versus Output Load

Efficiency versus Input Voltage Derating Output Load versus Ambient Temperature and Airflow

Vin(nom)

Page 12: DFEC30 - P-DUKE Characteristic...DFEC30 Application Note: Characteristic Curves 11/17/2016 P-DUKE TECHNOLOGY CO., LTD. 3 Characteristic Curves (Continued) All test conditions are at

DFEC30Application Note: Characteristic Curves

11/17/2016

P-DUKE TECHNOLOGY CO., LTD.

www.pduke.com 12

Characteristic Curves (Continued) All test conditions are at 25℃.The figures are identical for DFEC30-48D15

Typical Output Ripple and Noise. Transient Response to Dynamic Load Change from

Vin(nom); Full Load 100% to 75% to 100% of Full Load; Vin(nom)

Typical Input Start-Up and Output Rise Characteristic Using ON/OFF Voltage Start-Up and Output Rise Characteristic

Vin(nom); Full Load Vin(nom); Full Load

Page 13: DFEC30 - P-DUKE Characteristic...DFEC30 Application Note: Characteristic Curves 11/17/2016 P-DUKE TECHNOLOGY CO., LTD. 3 Characteristic Curves (Continued) All test conditions are at

DFEC30Application Note: Characteristic Curves

11/17/2016

P-DUKE TECHNOLOGY CO., LTD.

www.pduke.com 13

Characteristic Curves(Continued) All test conditions are at 25℃.The figures are identical for DFEC30-12S3P3

Efficiency versus Output Load Power Dissipation versus Output Load

Efficiency versus Input Voltage Derating Output Load versus Ambient Temperature and Airflow

Vin(nom)

Page 14: DFEC30 - P-DUKE Characteristic...DFEC30 Application Note: Characteristic Curves 11/17/2016 P-DUKE TECHNOLOGY CO., LTD. 3 Characteristic Curves (Continued) All test conditions are at

DFEC30Application Note: Characteristic Curves

11/17/2016

P-DUKE TECHNOLOGY CO., LTD.

www.pduke.com 14

Characteristic Curves (Continued) All test conditions are at 25℃.The figures are identical for DFEC30-12S3P3

Typical Output Ripple and Noise. Transient Response to Dynamic Load Change from

Vin(nom); Full Load 100% to 75% to 100% of Full Load; Vin(nom)

Typical Input Start-Up and Output Rise Characteristic Using ON/OFF Voltage Start-Up and Output Rise Characteristic

Vin(nom); Full Load Vin(nom); Full Load

Page 15: DFEC30 - P-DUKE Characteristic...DFEC30 Application Note: Characteristic Curves 11/17/2016 P-DUKE TECHNOLOGY CO., LTD. 3 Characteristic Curves (Continued) All test conditions are at

DFEC30Application Note: Characteristic Curves

11/17/2016

P-DUKE TECHNOLOGY CO., LTD.

www.pduke.com 15

Characteristic Curves (Continued) All test conditions are at 25℃.The figures are identical for DFEC30-12S05

Efficiency versus Output Load Power Dissipation versus Output Load

Efficiency versus Input Voltage Derating Output Load versus Ambient Temperature and Airflow

Vin(nom)

Page 16: DFEC30 - P-DUKE Characteristic...DFEC30 Application Note: Characteristic Curves 11/17/2016 P-DUKE TECHNOLOGY CO., LTD. 3 Characteristic Curves (Continued) All test conditions are at

DFEC30Application Note: Characteristic Curves

11/17/2016

P-DUKE TECHNOLOGY CO., LTD.

www.pduke.com 16

Characteristic Curves (Continued) All test conditions are at 25℃.The figures are identical for DFEC30-12S05

Typical Output Ripple and Noise. Transient Response to Dynamic Load Change from

Vin(nom); Full Load 100% to 75% to 100% of Full Load; Vin(nom)

Typical Input Start-Up and Output Rise Characteristic Using ON/OFF Voltage Start-Up and Output Rise Characteristic

Vin(nom); Full Load Vin(nom); Full Load

Page 17: DFEC30 - P-DUKE Characteristic...DFEC30 Application Note: Characteristic Curves 11/17/2016 P-DUKE TECHNOLOGY CO., LTD. 3 Characteristic Curves (Continued) All test conditions are at

DFEC30Application Note: Characteristic Curves

11/17/2016

P-DUKE TECHNOLOGY CO., LTD.

www.pduke.com 17

Characteristic Curves (Continued) All test conditions are at 25℃.The figures are identical for DFEC30-12S12

Efficiency versus Output Load Power Dissipation versus Output Load

Efficiency versus Input Voltage Derating Output Load versus Ambient Temperature and Airflow

Vin(nom)

Page 18: DFEC30 - P-DUKE Characteristic...DFEC30 Application Note: Characteristic Curves 11/17/2016 P-DUKE TECHNOLOGY CO., LTD. 3 Characteristic Curves (Continued) All test conditions are at

DFEC30Application Note: Characteristic Curves

11/17/2016

P-DUKE TECHNOLOGY CO., LTD.

www.pduke.com 18

Characteristic Curves (Continued) All test conditions are at 25℃.The figures are identical for DFEC30-12S12

Typical Output Ripple and Noise. Transient Response to Dynamic Load Change from

Vin(nom); Full Load 100% to 75% to 100% of Full Load; Vin(nom)

Typical Input Start-Up and Output Rise Characteristic Using ON/OFF Voltage Start-Up and Output Rise Characteristic

Vin(nom); Full Load Vin(nom); Full Load

Page 19: DFEC30 - P-DUKE Characteristic...DFEC30 Application Note: Characteristic Curves 11/17/2016 P-DUKE TECHNOLOGY CO., LTD. 3 Characteristic Curves (Continued) All test conditions are at

DFEC30Application Note: Characteristic Curves

11/17/2016

P-DUKE TECHNOLOGY CO., LTD.

www.pduke.com 19

Characteristic Curves (Continued) All test conditions are at 25℃.The figures are identical for DFEC30-12S15

Efficiency versus Output Load Power Dissipation versus Output Load

Efficiency versus Input Voltage Derating Output Load versus Ambient Temperature and Airflow

Vin(nom)

Page 20: DFEC30 - P-DUKE Characteristic...DFEC30 Application Note: Characteristic Curves 11/17/2016 P-DUKE TECHNOLOGY CO., LTD. 3 Characteristic Curves (Continued) All test conditions are at

DFEC30Application Note: Characteristic Curves

11/17/2016

P-DUKE TECHNOLOGY CO., LTD.

www.pduke.com 20

Characteristic Curves (Continued) All test conditions are at 25℃.The figures are identical for DFEC30-12S15

Typical Output Ripple and Noise. Transient Response to Dynamic Load Change from

Vin(nom); Full Load 100% to 75% to 100% of Full Load; Vin(nom)

Typical Input Start-Up and Output Rise Characteristic Using ON/OFF Voltage Start-Up and Output Rise Characteristic

Vin(nom); Full Load Vin(nom); Full Load

Page 21: DFEC30 - P-DUKE Characteristic...DFEC30 Application Note: Characteristic Curves 11/17/2016 P-DUKE TECHNOLOGY CO., LTD. 3 Characteristic Curves (Continued) All test conditions are at

DFEC30Application Note: Characteristic Curves

11/17/2016

P-DUKE TECHNOLOGY CO., LTD.

www.pduke.com 21

Characteristic Curves (Continued) All test conditions are at 25℃.The figures are identical for DFEC30-12S24

Efficiency versus Output Load Power Dissipation versus Output Load

Efficiency versus Input Voltage Derating Output Load versus Ambient Temperature and Airflow

Vin(nom)

Page 22: DFEC30 - P-DUKE Characteristic...DFEC30 Application Note: Characteristic Curves 11/17/2016 P-DUKE TECHNOLOGY CO., LTD. 3 Characteristic Curves (Continued) All test conditions are at

DFEC30Application Note: Characteristic Curves

11/17/2016

P-DUKE TECHNOLOGY CO., LTD.

www.pduke.com 22

Characteristic Curves (Continued) All test conditions are at 25℃.The figures are identical for DFEC30-12S24

Typical Output Ripple and Noise. Transient Response to Dynamic Load Change from

Vin(nom); Full Load 100% to 75% to 100% of Full Load; Vin(nom)

Typical Input Start-Up and Output Rise Characteristic Using ON/OFF Voltage Start-Up and Output Rise Characteristic

Vin(nom); Full Load Vin(nom); Full Load

Page 23: DFEC30 - P-DUKE Characteristic...DFEC30 Application Note: Characteristic Curves 11/17/2016 P-DUKE TECHNOLOGY CO., LTD. 3 Characteristic Curves (Continued) All test conditions are at

DFEC30Application Note: Characteristic Curves

11/17/2016

P-DUKE TECHNOLOGY CO., LTD.

www.pduke.com 23

Characteristic Curves (Continued) All test conditions are at 25℃.The figures are identical for DFEC30-12S28

Efficiency versus Output Load Power Dissipation versus Output Load

Efficiency versus Input Voltage Derating Output Load versus Ambient Temperature and Airflow

Vin(nom)

Page 24: DFEC30 - P-DUKE Characteristic...DFEC30 Application Note: Characteristic Curves 11/17/2016 P-DUKE TECHNOLOGY CO., LTD. 3 Characteristic Curves (Continued) All test conditions are at

DFEC30Application Note: Characteristic Curves

11/17/2016

P-DUKE TECHNOLOGY CO., LTD.

www.pduke.com 24

Characteristic Curves (Continued) All test conditions are at 25℃.The figures are identical for DFEC30-12S28

Typical Output Ripple and Noise. Transient Response to Dynamic Load Change from

Vin(nom); Full Load 100% to 75% to 100% of Full Load; Vin(nom)

Typical Input Start-Up and Output Rise Characteristic Using ON/OFF Voltage Start-Up and Output Rise Characteristic

Vin(nom); Full Load Vin(nom); Full Load

Page 25: DFEC30 - P-DUKE Characteristic...DFEC30 Application Note: Characteristic Curves 11/17/2016 P-DUKE TECHNOLOGY CO., LTD. 3 Characteristic Curves (Continued) All test conditions are at

DFEC30Application Note: Characteristic Curves

11/17/2016

P-DUKE TECHNOLOGY CO., LTD.

www.pduke.com 25

Characteristic Curves (Continued) All test conditions are at 25℃.The figures are identical for DFEC30-24S3P3

Efficiency versus Output Load Power Dissipation versus Output Load

Efficiency versus Input Voltage Derating Output Load versus Ambient Temperature and Airflow

Vin(nom)

Page 26: DFEC30 - P-DUKE Characteristic...DFEC30 Application Note: Characteristic Curves 11/17/2016 P-DUKE TECHNOLOGY CO., LTD. 3 Characteristic Curves (Continued) All test conditions are at

DFEC30Application Note: Characteristic Curves

11/17/2016

P-DUKE TECHNOLOGY CO., LTD.

www.pduke.com 26

Characteristic Curves (Continued) All test conditions are at 25℃.The figures are identical for DFEC30-24S3P3

Typical Output Ripple and Noise. Transient Response to Dynamic Load Change from

Vin(nom); Full Load 100% to 75% to 100% of Full Load; Vin(nom)

Typical Input Start-Up and Output Rise Characteristic Using ON/OFF Voltage Start-Up and Output Rise Characteristic

Vin(nom); Full Load Vin(nom); Full Load

Page 27: DFEC30 - P-DUKE Characteristic...DFEC30 Application Note: Characteristic Curves 11/17/2016 P-DUKE TECHNOLOGY CO., LTD. 3 Characteristic Curves (Continued) All test conditions are at

DFEC30Application Note: Characteristic Curves

11/17/2016

P-DUKE TECHNOLOGY CO., LTD.

www.pduke.com 27

Characteristic Curves (Continued) All test conditions are at 25℃.The figures are identical for DFEC30-24S05

Efficiency versus Output Load Power Dissipation versus Output Load

Efficiency versus Input Voltage Derating Output Load versus Ambient Temperature and Airflow

Vin(nom)

Page 28: DFEC30 - P-DUKE Characteristic...DFEC30 Application Note: Characteristic Curves 11/17/2016 P-DUKE TECHNOLOGY CO., LTD. 3 Characteristic Curves (Continued) All test conditions are at

DFEC30Application Note: Characteristic Curves

11/17/2016

P-DUKE TECHNOLOGY CO., LTD.

www.pduke.com 28

Characteristic Curves (Continued) All test conditions are at 25℃.The figures are identical for DFEC30-24S05

Typical Output Ripple and Noise. Transient Response to Dynamic Load Change from

Vin(nom); Full Load 100% to 75% to 100% of Full Load; Vin(nom)

Typical Input Start-Up and Output Rise Characteristic Using ON/OFF Voltage Start-Up and Output Rise Characteristic

Vin(nom); Full Load Vin(nom); Full Load

Page 29: DFEC30 - P-DUKE Characteristic...DFEC30 Application Note: Characteristic Curves 11/17/2016 P-DUKE TECHNOLOGY CO., LTD. 3 Characteristic Curves (Continued) All test conditions are at

DFEC30Application Note: Characteristic Curves

11/17/2016

P-DUKE TECHNOLOGY CO., LTD.

www.pduke.com 29

Characteristic Curves (Continued) All test conditions are at 25℃.The figures are identical for DFEC30-24S12

Efficiency versus Output Load Power Dissipation versus Output Load

Efficiency versus Input Voltage Derating Output Load versus Ambient Temperature and Airflow

Vin(nom)

Page 30: DFEC30 - P-DUKE Characteristic...DFEC30 Application Note: Characteristic Curves 11/17/2016 P-DUKE TECHNOLOGY CO., LTD. 3 Characteristic Curves (Continued) All test conditions are at

DFEC30Application Note: Characteristic Curves

11/17/2016

P-DUKE TECHNOLOGY CO., LTD.

www.pduke.com 30

Characteristic Curves (Continued) All test conditions are at 25℃.The figures are identical for DFEC30-24S12

Typical Output Ripple and Noise. Transient Response to Dynamic Load Change from

Vin(nom); Full Load 100% to 75% to 100% of Full Load; Vin(nom)

Typical Input Start-Up and Output Rise Characteristic Using ON/OFF Voltage Start-Up and Output Rise Characteristic

Vin(nom); Full Load Vin(nom); Full Load

Page 31: DFEC30 - P-DUKE Characteristic...DFEC30 Application Note: Characteristic Curves 11/17/2016 P-DUKE TECHNOLOGY CO., LTD. 3 Characteristic Curves (Continued) All test conditions are at

DFEC30Application Note: Characteristic Curves

11/17/2016

P-DUKE TECHNOLOGY CO., LTD.

www.pduke.com 31

Characteristic Curves (Continued) All test conditions are at 25℃.The figures are identical for DFEC30-24S15

Efficiency versus Output Load Power Dissipation versus Output Load

Efficiency versus Input Voltage Derating Output Load versus Ambient Temperature and Airflow

Vin(nom)

Page 32: DFEC30 - P-DUKE Characteristic...DFEC30 Application Note: Characteristic Curves 11/17/2016 P-DUKE TECHNOLOGY CO., LTD. 3 Characteristic Curves (Continued) All test conditions are at

DFEC30Application Note: Characteristic Curves

11/17/2016

P-DUKE TECHNOLOGY CO., LTD.

www.pduke.com 32

Characteristic Curves (Continued) All test conditions are at 25℃.The figures are identical for DFEC30-24S15

Typical Output Ripple and Noise. Transient Response to Dynamic Load Change from

Vin(nom); Full Load 100% to 75% to 100% of Full Load; Vin(nom)

Typical Input Start-Up and Output Rise Characteristic Using ON/OFF Voltage Start-Up and Output Rise Characteristic

Vin(nom); Full Load Vin(nom); Full Load

Page 33: DFEC30 - P-DUKE Characteristic...DFEC30 Application Note: Characteristic Curves 11/17/2016 P-DUKE TECHNOLOGY CO., LTD. 3 Characteristic Curves (Continued) All test conditions are at

DFEC30Application Note: Characteristic Curves

11/17/2016

P-DUKE TECHNOLOGY CO., LTD.

www.pduke.com 33

Characteristic Curves (Continued) All test conditions are at 25℃.The figures are identical for DFEC30-24S24

Efficiency versus Output Load Power Dissipation versus Output Load

Efficiency versus Input Voltage Derating Output Load versus Ambient Temperature and Airflow

Vin(nom)

Page 34: DFEC30 - P-DUKE Characteristic...DFEC30 Application Note: Characteristic Curves 11/17/2016 P-DUKE TECHNOLOGY CO., LTD. 3 Characteristic Curves (Continued) All test conditions are at

DFEC30Application Note: Characteristic Curves

11/17/2016

P-DUKE TECHNOLOGY CO., LTD.

www.pduke.com 34

Characteristic Curves (Continued) All test conditions are at 25℃.The figures are identical for DFEC30-24S24

Typical Output Ripple and Noise. Transient Response to Dynamic Load Change from

Vin(nom); Full Load 100% to 75% to 100% of Full Load; Vin(nom)

Typical Input Start-Up and Output Rise Characteristic Using ON/OFF Voltage Start-Up and Output Rise Characteristic

Vin(nom); Full Load Vin(nom); Full Load

Page 35: DFEC30 - P-DUKE Characteristic...DFEC30 Application Note: Characteristic Curves 11/17/2016 P-DUKE TECHNOLOGY CO., LTD. 3 Characteristic Curves (Continued) All test conditions are at

DFEC30Application Note: Characteristic Curves

11/17/2016

P-DUKE TECHNOLOGY CO., LTD.

www.pduke.com 35

Characteristic Curves (Continued) All test conditions are at 25℃.The figures are identical for DFEC30-24S28

Efficiency versus Output Load Power Dissipation versus Output Load

Efficiency versus Input Voltage Derating Output Load versus Ambient Temperature and Airflow

Vin(nom)

Page 36: DFEC30 - P-DUKE Characteristic...DFEC30 Application Note: Characteristic Curves 11/17/2016 P-DUKE TECHNOLOGY CO., LTD. 3 Characteristic Curves (Continued) All test conditions are at

DFEC30Application Note: Characteristic Curves

11/17/2016

P-DUKE TECHNOLOGY CO., LTD.

www.pduke.com 36

Characteristic Curves (Continued) All test conditions are at 25℃.The figures are identical for DFEC30-24S28

Typical Output Ripple and Noise. Transient Response to Dynamic Load Change from

Vin(nom); Full Load 100% to 75% to 100% of Full Load; Vin(nom)

Typical Input Start-Up and Output Rise Characteristic Using ON/OFF Voltage Start-Up and Output Rise Characteristic

Vin(nom); Full Load Vin(nom); Full Load

Page 37: DFEC30 - P-DUKE Characteristic...DFEC30 Application Note: Characteristic Curves 11/17/2016 P-DUKE TECHNOLOGY CO., LTD. 3 Characteristic Curves (Continued) All test conditions are at

DFEC30Application Note: Characteristic Curves

11/17/2016

P-DUKE TECHNOLOGY CO., LTD.

www.pduke.com 37

Characteristic Curves (Continued) All test conditions are at 25℃.The figures are identical for DFEC30-48S3P3

Efficiency versus Output Load Power Dissipation versus Output Load

Efficiency versus Input Voltage Derating Output Load versus Ambient Temperature and Airflow

Vin(nom)

Page 38: DFEC30 - P-DUKE Characteristic...DFEC30 Application Note: Characteristic Curves 11/17/2016 P-DUKE TECHNOLOGY CO., LTD. 3 Characteristic Curves (Continued) All test conditions are at

DFEC30Application Note: Characteristic Curves

11/17/2016

P-DUKE TECHNOLOGY CO., LTD.

www.pduke.com 38

Characteristic Curves (Continued) All test conditions are at 25℃.The figures are identical for DFEC30-48S3P3

Typical Output Ripple and Noise. Transient Response to Dynamic Load Change from

Vin(nom); Full Load 100% to 75% to 100% of Full Load; Vin(nom)

Typical Input Start-Up and Output Rise Characteristic Using ON/OFF Voltage Start-Up and Output Rise Characteristic

Vin(nom); Full Load Vin(nom); Full Load

Page 39: DFEC30 - P-DUKE Characteristic...DFEC30 Application Note: Characteristic Curves 11/17/2016 P-DUKE TECHNOLOGY CO., LTD. 3 Characteristic Curves (Continued) All test conditions are at

DFEC30Application Note: Characteristic Curves

11/17/2016

P-DUKE TECHNOLOGY CO., LTD.

www.pduke.com 39

Characteristic Curves (Continued) All test conditions are at 25℃.The figures are identical for DFEC30-48S05

Efficiency versus Output Load Power Dissipation versus Output Load

Efficiency versus Input Voltage Derating Output Load versus Ambient Temperature and Airflow

Vin(nom)

Page 40: DFEC30 - P-DUKE Characteristic...DFEC30 Application Note: Characteristic Curves 11/17/2016 P-DUKE TECHNOLOGY CO., LTD. 3 Characteristic Curves (Continued) All test conditions are at

DFEC30Application Note: Characteristic Curves

11/17/2016

P-DUKE TECHNOLOGY CO., LTD.

www.pduke.com 40

Characteristic Curves (Continued) All test conditions are at 25℃.The figures are identical for DFEC30-48S05

Typical Output Ripple and Noise. Transient Response to Dynamic Load Change from

Vin(nom); Full Load 100% to 75% to 100% of Full Load; Vin(nom)

Typical Input Start-Up and Output Rise Characteristic Using ON/OFF Voltage Start-Up and Output Rise Characteristic

Vin(nom); Full Load Vin(nom); Full Load

Page 41: DFEC30 - P-DUKE Characteristic...DFEC30 Application Note: Characteristic Curves 11/17/2016 P-DUKE TECHNOLOGY CO., LTD. 3 Characteristic Curves (Continued) All test conditions are at

DFEC30Application Note: Characteristic Curves

11/17/2016

P-DUKE TECHNOLOGY CO., LTD.

www.pduke.com 41

Characteristic Curves (Continued) All test conditions are at 25℃.The figures are identical for DFEC30-48S12

Efficiency versus Output Load Power Dissipation versus Output Load

Efficiency versus Input Voltage Derating Output Load versus Ambient Temperature and Airflow

Vin(nom)

Page 42: DFEC30 - P-DUKE Characteristic...DFEC30 Application Note: Characteristic Curves 11/17/2016 P-DUKE TECHNOLOGY CO., LTD. 3 Characteristic Curves (Continued) All test conditions are at

DFEC30Application Note: Characteristic Curves

11/17/2016

P-DUKE TECHNOLOGY CO., LTD.

www.pduke.com 42

Characteristic Curves (Continued) All test conditions are at 25℃.The figures are identical for DFEC30-48S12

Typical Output Ripple and Noise. Transient Response to Dynamic Load Change from

Vin(nom); Full Load 100% to 75% to 100% of Full Load; Vin(nom)

Typical Input Start-Up and Output Rise Characteristic Using ON/OFF Voltage Start-Up and Output Rise Characteristic

Vin(nom); Full Load Vin(nom); Full Load

Page 43: DFEC30 - P-DUKE Characteristic...DFEC30 Application Note: Characteristic Curves 11/17/2016 P-DUKE TECHNOLOGY CO., LTD. 3 Characteristic Curves (Continued) All test conditions are at

DFEC30Application Note: Characteristic Curves

11/17/2016

P-DUKE TECHNOLOGY CO., LTD.

www.pduke.com 43

Characteristic Curves (Continued) All test conditions are at 25℃.The figures are identical for DFEC30-48S15

Efficiency versus Output Load Power Dissipation versus Output Load

Efficiency versus Input Voltage Derating Output Load versus Ambient Temperature and Airflow

Vin(nom)

Page 44: DFEC30 - P-DUKE Characteristic...DFEC30 Application Note: Characteristic Curves 11/17/2016 P-DUKE TECHNOLOGY CO., LTD. 3 Characteristic Curves (Continued) All test conditions are at

DFEC30Application Note: Characteristic Curves

11/17/2016

P-DUKE TECHNOLOGY CO., LTD.

www.pduke.com 44

Characteristic Curves (Continued) All test conditions are at 25℃.The figures are identical for DFEC30-48S15

Typical Output Ripple and Noise. Transient Response to Dynamic Load Change from

Vin(nom); Full Load 100% to 75% to 100% of Full Load; Vin(nom)

Typical Input Start-Up and Output Rise Characteristic Using ON/OFF Voltage Start-Up and Output Rise Characteristic

Vin(nom); Full Load Vin(nom); Full Load

Page 45: DFEC30 - P-DUKE Characteristic...DFEC30 Application Note: Characteristic Curves 11/17/2016 P-DUKE TECHNOLOGY CO., LTD. 3 Characteristic Curves (Continued) All test conditions are at

DFEC30Application Note: Characteristic Curves

11/17/2016

P-DUKE TECHNOLOGY CO., LTD.

www.pduke.com 45

Characteristic Curves (Continued) All test conditions are at 25℃.The figures are identical for DFEC30-48S24

Efficiency versus Output Load Power Dissipation versus Output Load

Efficiency versus Input Voltage Derating Output Load versus Ambient Temperature and Airflow

Vin(nom)

Page 46: DFEC30 - P-DUKE Characteristic...DFEC30 Application Note: Characteristic Curves 11/17/2016 P-DUKE TECHNOLOGY CO., LTD. 3 Characteristic Curves (Continued) All test conditions are at

DFEC30Application Note: Characteristic Curves

11/17/2016

P-DUKE TECHNOLOGY CO., LTD.

www.pduke.com 46

Characteristic Curves (Continued) All test conditions are at 25℃.The figures are identical for DFEC30-48S24

Typical Output Ripple and Noise. Transient Response to Dynamic Load Change from

Vin(nom); Full Load 100% to 75% to 100% of Full Load; Vin(nom)

Typical Input Start-Up and Output Rise Characteristic Using ON/OFF Voltage Start-Up and Output Rise Characteristic

Vin(nom); Full Load Vin(nom); Full Load

Page 47: DFEC30 - P-DUKE Characteristic...DFEC30 Application Note: Characteristic Curves 11/17/2016 P-DUKE TECHNOLOGY CO., LTD. 3 Characteristic Curves (Continued) All test conditions are at

DFEC30Application Note: Characteristic Curves

11/17/2016

P-DUKE TECHNOLOGY CO., LTD.

www.pduke.com 47

Characteristic Curves (Continued) All test conditions are at 25℃.The figures are identical for DFEC30-48S28

Efficiency versus Output Load Power Dissipation versus Output Load

Efficiency versus Input Voltage Derating Output Load versus Ambient Temperature and Airflow

Vin(nom)

Page 48: DFEC30 - P-DUKE Characteristic...DFEC30 Application Note: Characteristic Curves 11/17/2016 P-DUKE TECHNOLOGY CO., LTD. 3 Characteristic Curves (Continued) All test conditions are at

DFEC30Application Note: Characteristic Curves

11/17/2016

P-DUKE TECHNOLOGY CO., LTD.

www.pduke.com 48

Characteristic Curves (Continued) All test conditions are at 25℃.The figures are identical for DFEC30-48S28

Typical Output Ripple and Noise. Transient Response to Dynamic Load Change from

Vin(nom); Full Load 100% to 75% to 100% of Full Load; Vin(nom)

Typical Input Start-Up and Output Rise Characteristic Using ON/OFF Voltage Start-Up and Output Rise Characteristic

Vin(nom); Full Load Vin(nom); Full Load


Recommended