+ All Categories
Home > Documents > DH Series · l Stainless Steel Filters Catridges. l Fabrication Code : IS 2825 / ASME SEC VIII...

DH Series · l Stainless Steel Filters Catridges. l Fabrication Code : IS 2825 / ASME SEC VIII...

Date post: 14-Jun-2020
Category:
Upload: others
View: 0 times
Download: 0 times
Share this document with a friend
2
Heat of Compression Air Dryers DH Series No power requirement for Regeneration. Energy saving dewpoint based changover. Stainless Steel Filters Catridges. Fabrication Code : IS 2825 / ASME SEC VIII optional. Dewpoint better than -40 o C. Energy efficient Coolers. SS Support desiccant bed. Low energy consumption. Fully automatic continuous operation.
Transcript
Page 1: DH Series · l Stainless Steel Filters Catridges. l Fabrication Code : IS 2825 / ASME SEC VIII optional. l Dewpoint better than -40o C. l Energy efficient Coolers. l SS Support desiccant

Heat of Compression Air Dryers

DH Series

l No power requirement for Regeneration.

l Energy saving dewpoint based changover.

l Stainless Steel Filters Catridges.

l Fabrication Code : IS 2825 / ASME SEC VIII optional.

l Dewpoint better than -40o C.

l Energy efficient Coolers.

l SS Support desiccant bed.

l Low energy consumption.

l Fully automatic continuous operation.

Page 2: DH Series · l Stainless Steel Filters Catridges. l Fabrication Code : IS 2825 / ASME SEC VIII optional. l Dewpoint better than -40o C. l Energy efficient Coolers. l SS Support desiccant

Sales & Ahmedabad Bangalore Chennai Delhi Hyderabad & Kolkatta Mumbai & PuneService Outlets 98673 67726 98450 93322 97894 80564 93113 10726 98854 45321 98673 67726

Trident Pneumatics Pvt Ltd5/232, K.N.G. Pudur Road, Coimbatore - 641 108, India. Ph : +91-422-2400492, 2401373 Fax : +91-422-2401376

e-mail : [email protected] Website : www.tridentpneumatics.com

09 /

14

Our Other Range of Products

l Time based Auto Drain Valve l Level Sensing Auto Drain Valvel Desiccant Dryer (Heatless) l Refrigeration type Dryer

l Micro Filter l Air / Water Cooled After Cooler l Air Receiverl Blower Reactivated Dryers l No Loss Split Flow Dryers

Principle of Operation

In Heat of compression air dryers, we use hot

compressed (120 deg C to 180 deg) air as regeneration

medium for regenerating the saturated desiccant

without any additional heater. Hence running cost for

HOC Dryers are virtually Nil. The hot air which is used

for regeneration is cooled by after cooler to bring

down the temperature to 45 deg C and less, is fed

into another tower for Adsorption.

These Dryers are working on 8 + 8 Hrs cycle. In 8

Hrs. Cycle the hot air is fed for regeneration of

desiccant bed for 4.30 Hrs and remaining 2.30 Hrs.

a changeover takes place where the air is first cooled

in an after cooler to bring down the temperature to

less than 45 deg C, then it is dried. Before going to

the outlet, It cools the regenerated desiccant bed,

thus bringing it down to ambient temperature. This

cycle is reversed for the next 8 Hrs.

Consultant Approvals

l EIL l Tata Consulting Engineers l Technip KT India

Ltd l Mott MacDonald Pvt Ltd l Uhde India l Avant

Garde l Barc l Punj Lloyd l Bhavini l Foster wheeler

l Mecon l Alstom l NHPC Hydel l Tecproashtech

l Macawber Beekay l Linde l BOC ..... etc...

DH Series Specifications

Inlet Flow EndModel cfm Nm3/min Connection

DH 500 500 11 50 NB

DH 1000 1000 22 80 NB

DH 1500 1500 33 100 NB

DH 2000 2000 44 100 NB

DH 2500 2500 55 150 NB

DH 3000 3000 66 150 NB

DH 3500 3500 77 150 NB

DH 4000 4000 88 150 NB

DH 5000 5000 110 200 NB

Specifications are subjected to change as per customerrequirement.

Designed for Air Inlet Pressure 7 Kg/cm2

Designed for Air Inlet temperature 45oC

Designed for Ambient temperature 40oC

Desiccant : Activated alumina / Silica gel based ontemperature

Heat of Compression Air Dryer


Recommended