MTU 16V4000 DS2250DieselGeneratorSet
Producthighlights
380V–11kV/50Hz/primepower/fuelconsumptionoptimized16V4000G14F/waterchargeaircooling
Bene� ts— Lowfuelconsumption— Optimizedsystemintegrationability— Highreliability— Highavailabilityofpower— Longmaintenanceintervals
Support— Globalproductsupportoffered
Standards— Engine-generatorsetisdesignedandmanufacturedinfacilitiescertifiedtostandardsISO2008:9001andISO2004:14001
— GeneratorsetcompliestoISO8528— GeneratormeetsNEMAMG1,BS5000,ISO,DINENandIECstandards
— NFPA110
Power rating— Systemratings:2120kVA-2160kVA— AcceptsratedloadinonestepperNFPA110— GeneratorsetcompliestoG3accordingtoISO8528-5— GeneratorsetexceedsloadstepsaccordingtoISO8528-5
Performance assurance certi� cation (PAC)— Engine-generatorsettestedtoISO8528-5fortransientresponse— 75%loadfactor— Verifiedproductdesign,qualityandperformanceintegrity— Allenginesystemsareprototypeandfactorytested
Complete range of accessories available— Controlpanel— Powerpanel— Circuitbreaker/powerdistribution— Fuelsystem— Fuelconnectionswithshut-offvalvemountedtobaseframe— Starting/chargingsystem— Exhaustsystem— Mechanicalandelectricaldrivenradiators— Mediumandoversizedvoltagealternators
Emissions— Fuelconsumptionoptimized
Certi� cations— CEcertificationoption— Unitcertificateacc.toBDEW(GermanGrid-Code)
Application data 1)
1 AlldatarefersonlytotheengineandisbasedonISOstandardconditions(25°Cand100mabovesealevel).2 ValuesreferencedareinaccordancewithISO3046-1.Conversioncalculatedwithfueldensityof0.83g/ml.Allfuelconsumptionvaluesrefertoratedenginepower.
Standardandoptionalfeatures
System ratings (kW/kVA)
Generator model Voltage fuel consumption optimized
without radiator with mechanical radiator
kWel kVA* AMPS kWel kVA* AMPS
LeroySomerLSA52.3S7(LowvoltageLeroySomerstandard)
380V 1728 2160 3282 1688 2110 3206
400V 1728 2160 3118 1688 2110 3046
415V 1728 2160 3005 1688 2110 2935
LeroySomerLSA52.3L12(LowvoltageLeroySomeroversized)
380V 1728 2160 3282 1688 2110 3206
400V 1728 2160 3118 1688 2110 3046
415V 1728 2160 3005 1688 2110 2935
Marathon744RSL7092(LowvoltageMarathon)
380V 1704 2130 3236 1672 2090 3175
400V 1704 2130 3074 1672 2090 3017
415V 1696 2120 2949 1672 2090 2908
Marathon744RSL7093(LowvoltageMarathonoversized)
380V 1704 2130 3236 1672 2090 3175
400V 1704 2130 3074 1672 2090 3017
415V 1696 2120 2949 1672 2090 2908
Marathon1020FDH7097(Mediumvolt.marathon)
11kV 1712 2140 112 1672 2090 110
LeroySomerLSA53.2XL9(Mediumvolt.LeroySomer)
11kV 1728 2160 113 1688 2110 111
*cosphi=0.8
EngineManufacturer MTUModel 16V4000G14FType 4-cycleArrangement 16VDisplacement:l 76.3Bore:mm 170Stroke:mm 210Compressionratio 16.4Ratedspeed:rpm 1500Enginegovernor ECU9Maxpower:kWm 1798Aircleaner dry
Fuel systemMaximumfuellift:m 5Totalfuelflow:l/min 20
Fuel consumption 2) l/hr g/kwhAt100%ofpowerrating: 407.3 188At75%ofpowerrating: 310.3 191At50%ofpowerrating: 217.7 201
Liquid capacity (lubrication)Totaloilsystemcapacity:l 300Enginejacketwatercapacity:l 175Intercoolercoolantcapacity:l 50
Combustion air requirementsCombustionairvolume:m3/s 2.1Max.airintakerestriction:mbar 50
Cooling/radiator systemCoolantflowrate(HTcircuit):m3/hr 68.5Coolantflowrate(LTcircuit):m3/hr 30Heatrejectiontocoolant:kW 710Heatradiatedtochargeaircooling:kW 260Heatradiatedtoambient:kW 90Fanpowerforelectr.radiator(40°C):kW 38
Exhaust systemExhaustgastemp.(afterturbocharger):°C 480Exhaustgasvolume:m3/s 5.4Maximumallowablebackpressure:mbar 85Minimumallowablebackpressure:mbar 30
Generator
Standard and optional features
Representsstandardfeatures
Representsoptionalfeatures
Cooling system
Jacketwaterpump Thermostat(s) Waterchargeaircooling
Mechanicalradiator Electricaldrivenfront-endcooler Jacketwaterheater
Control panel
Pre-wiredcontrolcabinetforeasyapplicationofcustomizedcontroller(V1+) Islandoperation(V2) AutomaticmainsfailureoperationwithATS(V3a) Automaticmainsfailureoperationincl.controlofgeneratorandmainsbreaker(V3b) Islandparalleloperationofmultiplegensets(V4) Automaticmainsfailureoperationwithshort(<10s)mainsparalleloverlapsynchronization(V5) Mainsparalleloperationofasinglegenset(V6)
Mainsparalleloperationofmultiplegensets(V7) Baslercontroller Deifcontroller Completesystemmetering Digitalmetering Engineparameters Generatorprotectionfunctions Engineprotection SAEJ1939engineECUcommunications Parametrizationsoftware Multilingualcapability Multipleprogrammablecontactinputs Multiplecontactoutputs
Eventrecording IP54frontpanelratingwithintegratedgasket Differentexpansionmodules Remoteannunciator Daytankcontrol Generatorwindingtemperaturemonitoring Generatorbearingtemperaturemonitoring ModbusTCP-IP
Power panel
Availablein600x600and600x1000 Phasemonitoringrelay230V/400V Supplyforbatterycharger Supplyforjacketwaterheater
Supplyforanticondensationheating Plugsocketcabinetfor230VcompatibleEuro/USA
Supplyforelectricaldrivenradiatorfrom45kW–75kW(PP600x1000)
4polethree-phasesynchronousgenerator Brushless,self-excited,self-regulating,self-ventilated Digitalvoltageregulator Anticondensationheater StatorwindingY-connected,accessibleneutral(broughtout) ProtectionIP23
InsulationclassH,utilizationacc.toH RadiosuppressionEN55011,group1,cl.B Shortcircuitcapability3xInfor10sec WindingandbearingRTDs(withoutmonitoring) ExcitationbyAREP MountingofCT´s:2coreCT´s Windingpitch:2/3winding Voltagesetpointadjustment±10%
MeetsNEMAMG-1,BS5000,IEC60034-1,VDE0530,DINEN12601,AS1359andISO8528requirements LeroySomerlowvoltagegenerator Marathonlowvoltagegenerator Oversizedgenerator Mediumvoltagegenerator
Engine
4-cycle Standardsinglestageairfilter Oildrainextension&shut-offvalve
Closedcrankcaseventilation Governor-electronicisochronous Commonrailfuelinjection
Fuelconsumptionoptimizedengine
Standard and optional features
Circuit breaker/power distribution
3-polecircuitbreaker 4-polecircuitbreaker
Manual-actuatedcircuitbreaker Electrical-actuatedcircuitbreaker
Stand-alonesolutioninseperatecabinet
Fuel system
Flexiblefuelconnectorsmountedtobaseframe Fuelfilterwithwaterseparator Fuelfilterwithwaterseparatorheavy-duty
Switchablefuelfilterwithwaterseparator Switchablefuelfilterwithwaterseparatorheavy-duty Seperatefuelcooler
Fuelcoolerintegratedintocoolingequipment
Starting/charging system
24Vstarter Starterbatteries,cables,rack,disconnectswitch
Batterycharger
Mounting system
Weldedbaseframe Resilientengineandgeneratormounting Modularbaseframedesign
Representsstandardfeatures
Representsoptionalfeatures
Exhaust system
Exhaustbellowswithconnectionflange Exhaustsilencerwith10dB(A)soundattenuation
Exhaustsilencerwith30dB(A)soundattenuation
Exhaustsilencerwith40dB(A)soundattenuation Y-connection-pipe
Rolls-Royce Groupwww.mtu-solutions.com/powergen
Weights and dimensions
Sound data
— Consult your local MTU distributor for sound data.
Emissions data
— Consult your local MTU distributor for emissions data.
Drawing above for illustration purposes only, based on a standard open power 400 Volt engine-generator set. Lengths may vary with other voltages. Do not use for installation design. See website for unit specific template drawings.
Sub
ject
to
chan
ge.
| 32
3750
1 | E
diti
on 0
1/20
| ES
M 2
020
-03.
Weights and dimensions are based on open power units and are estimates only. Consult the factory for accurate weights and dimensions for your specific engine-generator set.
System Dimensions (L x W x H) Weight (dry/less tank)
Open power unit (OPU) 4766 x 1810 x 2330 mm 12428 kg
Ratingdefinitionsandconditions
— Primepowerratingsapplytoinstallationswhereutilitypowerisunavailableorunreliable.Atvaryingload,thenumberofgeneratorsetoperatinghoursisunlimited.A10%overloadcapacityisavailableforonehourintwelve.RatingsareinaccordancewithISO8528-1,ISO3046-1,BS5514andAS2789.Averageloadfactor:≤75%.— Consultyourlocaldistributorforderatinginformation.