Date post: | 30-Mar-2018 |
Category: |
Documents |
Upload: | nguyenquynh |
View: | 260 times |
Download: | 5 times |
Digital Receiver Digital Receiver Unit Unit -- HLRHLR
Product Launch Package
Refrigeration Marketing Units
Emerson Climate Technologies Europe
� Outdoor Installations, such as Convenience stores, Small Retail Stores and Large Kitchen equipment
Emerson Climate TechnologiesEmerson Climate TechnologiesExisting Digital Range Existing Digital Range –– Application Application Emerson Climate TechnologiesEmerson Climate TechnologiesExisting Digital Range Existing Digital Range –– Application Application
Copeland EazyCool Digital Unit
Digital HLR Liquid receiver Unit, Page 2
� Indoor Installations with machine room, as Small Retail & Hard Discount Stores and Storage Warehouse
Copeland EazyCool Network Digital
MC Indoor Scroll Digital Unit
Copeland Digital Receiver Unit HLRCopeland Digital Receiver Unit HLRBenefitsBenefitsCopeland Digital Receiver Unit HLRCopeland Digital Receiver Unit HLRBenefitsBenefits
• HLR Digital Scroll Receiver Unit for remote condenser installations
– Compact design, reduced footprint = space Gain
– Digital modulation = one unit for all store refrigeration system
– Reduced sound level with remote condenser and low noise fans or water cooled condenser
Digital HLR Liquid receiver Unit, Page 3
– Increased system efficiency by generous condenser sizing opportunities
– Energy saving by using most efficient Digital Scroll technology
– Quick and easy installation due to complete equipment scope and clear design
HLR Benefits vs. CompetitionHLR Benefits vs. CompetitionHLR Benefits vs. CompetitionHLR Benefits vs. Competition
� Wider range of capacity modulation then SH compressor
- 10-100 % modulation with HLR and single compressor
- 5-100 % modulation with HLR and tandem compressor
- 43-100 % modulation with competitive SH and inverter control
- 50/100 % modulation with competitive SH and tandem compressor
Digital HLR Liquid receiver Unit, Page 4
- 50/100 % modulation with competitive SH and tandem compressor
� Best in class efficiency
- 5% to 10% efficiency
advantage depending
on model
* 100% capacity
Copeland Digital Receiver Unit HLR Copeland Digital Receiver Unit HLR Differences Vs Traditional Digital unitsDifferences Vs Traditional Digital unitsCopeland Digital Receiver Unit HLR Copeland Digital Receiver Unit HLR Differences Vs Traditional Digital unitsDifferences Vs Traditional Digital units
Digital HLR Liquid receiver Unit, Page 5
� Digital Receiver Unit (HLR)
– Digital Compressor
– Electrical panel with:
• EC2-552 & PT4
• Contactor & overload protector
– Liquid line w/ Drier & Sight Glass
� Indoor & Outdoor Digital Unit
– Digital Compressor
– Electrical panel with:
• EC2-55x & PT4
• Contactor & overload protector
– Liquid line w/ Drier & Sight Glass
– Air cooled condenser
– Fan speed controller
Copeland Digital Receiver Unit HLRCopeland Digital Receiver Unit HLRRange lineRange line--upupCopeland Digital Receiver Unit HLRCopeland Digital Receiver Unit HLRRange lineRange line--upup
� 4 Models based on actual Digital compressors release
– Single compressor unit 7 & 10 kW
– Tandem compressor unit 14 & 20 kW
12
Tan
dem LRH24-ZBD90KCE12
Tan
dem HLR31-ZBDT90
Digital HLR Liquid receiver Unit, Page 6
4
6
8
HP kW
Tan
dem
Sin
gle
1 3 6 8 11 13 16 18 21
LRH24-ZBD60KCE
LRH13-ZBD45KCE
LRH13-ZBD30KCE
@@--10/3210/32°°C, Return gas 20C, Return gas 20°°C C -- R404A RefrigerantR404A Refrigerant
4
6
8
HP kW
Tan
dem
Sin
gle
1 3 6 8 11 13 16 18 21
HLR13 HLR13 HLR13 HLR13 ----ZBD30ZBD30ZBD30ZBD30
HLR13-ZBD45
HLR31-ZBDT60
1 3 6 8 11 13 16 18 21@@--10/3210/32°°C, Return gas 20C, Return gas 20°°C C -- R404A RefrigerantR404A Refrigerant
Emerson Climate TechnologiesEmerson Climate TechnologiesDigital Condensing Unit RangesDigital Condensing Unit RangesEmerson Climate TechnologiesEmerson Climate TechnologiesDigital Condensing Unit RangesDigital Condensing Unit Ranges
Digital EazyCool
Digital EazyCool
Network
Digital HLR Liquid receiver Unit, Page 7
0 10 20 30 40 50 60 70 80
Digital "MC"
Digital "HLR"
kWMT Rating @ -10/32°C - Return gas temp 20°C
Emerson Climate TechnologiesEmerson Climate TechnologiesDigital Condensing Unit RangesDigital Condensing Unit RangesEmerson Climate TechnologiesEmerson Climate TechnologiesDigital Condensing Unit RangesDigital Condensing Unit Ranges
Corner Shop, Proximity,
Convenience Stores &
Petrol Station
Bar & Restaurant
Kitchen equipment
Hard Discount
Small Supermarket
Machine room
City
Digital HLR Liquid receiver Unit, Page 8
No Machine
room
7 & 10 kW 7, 10, 14 & 20 kW 14 & 20 kW - 24~80 kW
Modulation range 0.7~10 kW 0.7~20 kW 0.7~20 kW@ 32°C Amb Temp - 20°C returned gas
* 24 kW with 2 unit network (Digital unit as master) & 80 kW with 4 units in network (Digital unit as master)
City
Centre
Capacity @ MT
Copeland Digital Receiver Unit HLRCopeland Digital Receiver Unit HLRLeafletLeafletCopeland Digital Receiver Unit HLRCopeland Digital Receiver Unit HLRLeafletLeaflet
Digital HLR Liquid receiver Unit, Page 9
– Receiver Unit is part of Condensing Units (below item “Indoor”)
– Performance and Data ratings are the same as for the relevant compressors
Copeland Digital Receiver Unit HLRCopeland Digital Receiver Unit HLRSelectSelectCopeland Digital Receiver Unit HLRCopeland Digital Receiver Unit HLRSelectSelect
Digital HLR Liquid receiver Unit, Page 10
Copeland Digital Receiver Unit HLRCopeland Digital Receiver Unit HLRScope of SupplyScope of SupplyCopeland Digital Receiver Unit HLRCopeland Digital Receiver Unit HLRScope of SupplyScope of Supply
Pressure transmitters PT4
24 Volt Digital Solenoid Valve
Filter Drier ADK ALCO
Liquid receiver liquid line outlet
Compressor discharge line
Digital HLR Liquid receiver Unit, Page 11
HP/LP PS2 Pressure Switch
Sight glass ALCO
Filter Drier ADK ALCO
Electrical box with:
• EC2-552 Digital Unit controller
• Overload protector & contactor
Receiver Sight glass
Copeland Digital Receiver Unit HLRCopeland Digital Receiver Unit HLRSingle unit DimensionsSingle unit DimensionsCopeland Digital Receiver Unit HLRCopeland Digital Receiver Unit HLRSingle unit DimensionsSingle unit Dimensions
Digital HLR Liquid receiver Unit, Page 12
Copeland Digital Receiver Unit HLRCopeland Digital Receiver Unit HLRScope of supplyScope of supplyCopeland Digital Receiver Unit HLRCopeland Digital Receiver Unit HLRScope of supplyScope of supply
Pressure transmitters PT4
Electrical box with:
• Overload protector
• contactor
•EC2-552 Digital Unit controller
Receiver Sight glass
HP Pressure switch ALCO
Digital HLR Liquid receiver Unit, Page 13
ALCO LP PS1 Pressure Switch
Sight glass ALCO
Filter Drier ADK ALCO
Oil separator ALCO
Liquid line outlet to
evaporators
Liquid inlet (from condenser)
HP Pressure switch ALCO PS3 (on each comp)
Digital Compressor
Suction Line
Discharge line to condenser
Copeland Digital Receiver Unit HLRCopeland Digital Receiver Unit HLRTandem Unit DimensionsTandem Unit DimensionsCopeland Digital Receiver Unit HLRCopeland Digital Receiver Unit HLRTandem Unit DimensionsTandem Unit Dimensions
Digital HLR Liquid receiver Unit, Page 14
Copeland Digital Receiver Unit HLRCopeland Digital Receiver Unit HLRSpecificationsSpecificationsCopeland Digital Receiver Unit HLRCopeland Digital Receiver Unit HLRSpecificationsSpecifications
HLR 13-ZBD30KCE HLR 13-ZBD45KCE HLR31-ZBDT60KCE HLR31-ZBDT90KCE
HP 4 6 8 12Capacity (kW)@ Te.-10, Td: 45°C RGT 20°C
7,0 10,2 14,1 20,3
Receiver with sight Glass 13 l 13 l 31 l 31 l
Suction Line Ø (inch) 7/8 7/8 1 3/8 1 3/8
Discharge line Ø (inch) 5/8" 5/8" 7/8" 7/8"Liquid Receiver Inlet Ø (inch) 5/8 5/8 5/8 5/8
Liquid Receiver Outlet Ø (inch) 5/8 5/8 5/8 5/8
Height (mm) 710 710 910 910
Digital Receiver Unit
Single Compressor Unit Tandem Compressors Unit
Digital HLR Liquid receiver Unit, Page 15
710 710 910 910Length (mm) 690 690 920 920
width (mm) 400 400 400 400
Weight (kg) 90 90 130 130Electrical box (IP54) With:
Overload √ √ √ √contactor √ √ √ √Fuse √ √ √ √
EC2-552-Controller √ √ √ √
Liquid line Equipped with
Filter drier √ √ √ √Sight glass √ √ √ √
HP/LP Switch PS2 (HP/LP) PS2 (HP/LP) PS1 +PS3 PS1 + PS3Oil Separator - - √ √
All TFD Voltag 3~ 380-420 V
@ MT standard conditions EN12900,
R404A