Dileptons in PHENIX Deepali Sharma for the PHENIX Collaboration Stony Brook University 12th June, 2012 Deepali Sharma (Stony Brook University) RHIC/AGS Annual Users’ Meeting 2012 12th June, 2012 1 / 23
Transcript
Page 1: Dileptons in PHENIX · Dileptons in PHENIX Deepali Sharma for the PHENIX Collaboration Stony Brook University 12th June, 2012 Deepali Sharma (Stony Brook University) RHIC/AGS Annual

Dileptons in PHENIX

Deepali Sharma

for the PHENIX Collaboration

Stony Brook University

12th June, 2012

Deepali Sharma (Stony Brook University) RHIC/AGS Annual Users’ Meeting 2012 12th June, 2012 1 / 23

Page 2: Dileptons in PHENIX · Dileptons in PHENIX Deepali Sharma for the PHENIX Collaboration Stony Brook University 12th June, 2012 Deepali Sharma (Stony Brook University) RHIC/AGS Annual

Outline

1 Motivation

2 PHENIX experimental set-up

3 Cocktail generation

4 Dileptons in PHENIX for various collision systems

5 The future: Hadron Blind Detector

Deepali Sharma (Stony Brook University) RHIC/AGS Annual Users’ Meeting 2012 12th June, 2012 2 / 23

Page 3: Dileptons in PHENIX · Dileptons in PHENIX Deepali Sharma for the PHENIX Collaboration Stony Brook University 12th June, 2012 Deepali Sharma (Stony Brook University) RHIC/AGS Annual

Motivation

Dilepton mass spectrum

Diverse physics signalThermal radiation:QGP (qq→ γ∗ → e+e−)HG (π+π− → ρ→ e+e−)

light vector mesons and low-masscontinuum: sensitive to chiral symmetryrestoration that will appear as mass shifts,broadening or excess yield.

open heavy flavor: thermal radiation andmedium modification.

quarkonia: suppression/enhancement ofquarkonium production reveals criticalfeatures of the medium.

Modifications to the dilepton spectrum dueto the QCD phase transition

Deepali Sharma (Stony Brook University) RHIC/AGS Annual Users’ Meeting 2012 12th June, 2012 3 / 23

Page 4: Dileptons in PHENIX · Dileptons in PHENIX Deepali Sharma for the PHENIX Collaboration Stony Brook University 12th June, 2012 Deepali Sharma (Stony Brook University) RHIC/AGS Annual

PHENIX Experimental set-up

PHENIX Central arms Acceptance: -0.35< η <0.35, 2×90◦ in ϕ

Collision sysytems: p+p, d+Au,Cu+Cu, Au+Au

Vertex: BBCTracking: DC/PC1pe > 0.2 GeV/c;

Electron identification based on:

RICH (Ring ImagingCerenkov detector) (e/πrejection >1000)

EMCal (ElectromagneticCalorimeter) (E-p matching,e/π rejection ∼ 10)

Deepali Sharma (Stony Brook University) RHIC/AGS Annual Users’ Meeting 2012 12th June, 2012 4 / 23

Page 5: Dileptons in PHENIX · Dileptons in PHENIX Deepali Sharma for the PHENIX Collaboration Stony Brook University 12th June, 2012 Deepali Sharma (Stony Brook University) RHIC/AGS Annual

Cocktail of hadronic sources

Hadron decaysFit the π± and π0 data for a givencollision system

Ed3σ

dp3=

A

(e−(apT +bp2T ) + pT/p0)n

For all other mesons, use mT scaling:

pT →√

p2T − m2

π0 + m2hadron

and fix normalization using the existingdata where available.

Charm, Bottom, Drell Yan from PYTHIAFor a given collision system use Ncoll ×σcc = 567± 57± 193 measured in p + pfrom single electrons.

Put the ideal PHENIX acceptance filter.

Deepali Sharma (Stony Brook University) RHIC/AGS Annual Users’ Meeting 2012 12th June, 2012 5 / 23

Page 6: Dileptons in PHENIX · Dileptons in PHENIX Deepali Sharma for the PHENIX Collaboration Stony Brook University 12th June, 2012 Deepali Sharma (Stony Brook University) RHIC/AGS Annual

What PHENIX has measured so far ....

Deepali Sharma (Stony Brook University) RHIC/AGS Annual Users’ Meeting 2012 12th June, 2012 6 / 23

Page 7: Dileptons in PHENIX · Dileptons in PHENIX Deepali Sharma for the PHENIX Collaboration Stony Brook University 12th June, 2012 Deepali Sharma (Stony Brook University) RHIC/AGS Annual

Dileptons in PHENIX: p + p collisions

Inclusive mass spectrum of e+e−

measured from m = 0 to m = 8GeV/c2.Very well understood in terms of

- hadron cocktail at low masses.- heavy Flavor + DY at high

masses

Charm: integration aftercocktail subtraction;σcc = 544± 39(stat)± 142(sys)±200(model)µb (consistent withPHENIX single electron measurement)Simultaneous fit of charm andbottom;

- σcc = 518± 47(stat)±135(sys)± 190(model)µb

- σbb =

3.9± 2.4(stat)±3−2 (sys)µb

PLB 670, 313 (2009)

0 1 2 3 4 5 6 7 8

/Ge

V)

IN P

HE

NIX

AC

CE

PT

AN

CE

2 (

cee

dN

/dm

evt

1/N

-1010

-910

-810

-710

-610

-510

-410

-310 = 200 GeVsp+p at DATA

|y| < 0.35

> 0.2 GeV/cT

p

0 1 2 3 4 5 6 7 8

/Ge

V)

IN P

HE

NIX

AC

CE

PT

AN

CE

2 (

cee

dN

/dm

evt

1/N

-1010

-910

-810

-710

-610

-510

-410

-310

)2

(GeV/ceem

0 0.2 0.4 0.6 0.8 1

/Ge

V)

IN P

HE

NIX

AC

CE

PT

AN

CE

2 (

ce

e d

N/d

me

vt

1/N

-710

-610

-510

-410

-310

eeγ → 0π

eeγ → η

eeγ →’ η

ee→ ρ

ee0

π ee & → ω

eeη ee & → φ

ee→ ψJ/

ee→’ ψ

ee (PYTHIA)→ cc

ee (PYTHIA)→ bb

ee (PYTHIA)→DY

sum

)2

(GeV/ceem

0 0.2 0.4 0.6 0.8 1

/Ge

V)

IN P

HE

NIX

AC

CE

PT

AN

CE

2 (

ce

e d

N/d

me

vt

1/N

-710

-610

-510

-410

-310

)2 (GeV/ceem0 1 2 3 4 5 6 7 8

Data

/Cockta

il

0

0.5

1

1.5

Deepali Sharma (Stony Brook University) RHIC/AGS Annual Users’ Meeting 2012 12th June, 2012 7 / 23

Page 8: Dileptons in PHENIX · Dileptons in PHENIX Deepali Sharma for the PHENIX Collaboration Stony Brook University 12th June, 2012 Deepali Sharma (Stony Brook University) RHIC/AGS Annual

Dileptons in PHENIX: d + Au collisions (Minimum bias)

Deepali Sharma (Stony Brook University) RHIC/AGS Annual Users’ Meeting 2012 12th June, 2012 8 / 23

Page 9: Dileptons in PHENIX · Dileptons in PHENIX Deepali Sharma for the PHENIX Collaboration Stony Brook University 12th June, 2012 Deepali Sharma (Stony Brook University) RHIC/AGS Annual

Dileptons in PHENIX: d + Au collisions (Minimum bias)

Consistent with the expected cocktail of known sources both in low-mass andintermediate mass region.

large mass range coverage 0− 14 GeV/c2.

Data will constrain known sources with better precison, e.g. bottomcross-section.

Deepali Sharma (Stony Brook University) RHIC/AGS Annual Users’ Meeting 2012 12th June, 2012 8 / 23

Page 10: Dileptons in PHENIX · Dileptons in PHENIX Deepali Sharma for the PHENIX Collaboration Stony Brook University 12th June, 2012 Deepali Sharma (Stony Brook University) RHIC/AGS Annual

Comparison of d + Au to scaled p + p data

Low mass region

No excess in LMR.

d + Au consistent with scaled p + p.

Intermediate mass region

No excess in IMR.

d + Au consistent with scaled p + p.

J/ψ suprresion ∼ 0.75 observed.

Deepali Sharma (Stony Brook University) RHIC/AGS Annual Users’ Meeting 2012 12th June, 2012 9 / 23

Page 11: Dileptons in PHENIX · Dileptons in PHENIX Deepali Sharma for the PHENIX Collaboration Stony Brook University 12th June, 2012 Deepali Sharma (Stony Brook University) RHIC/AGS Annual

Dileptons in PHENIX: Au + Au collisions

Au + Au (PRC 79, 81 034911(2010))

partN0 50 100 150 200 250 300 350

)-8

(10

coll

Yie

ld/N

0

2

4

6

8

10

12

14

16

18

20

= 200 GeVNN

sAu+Au

coll)/ N

2<2.8 GeV/c

eeYield (1.2<m

p+p

Au+Au

PYTHIA

crandom c

Deepali Sharma (Stony Brook University) RHIC/AGS Annual Users’ Meeting 2012 12th June, 2012 10 / 23

Page 12: Dileptons in PHENIX · Dileptons in PHENIX Deepali Sharma for the PHENIX Collaboration Stony Brook University 12th June, 2012 Deepali Sharma (Stony Brook University) RHIC/AGS Annual

Dileptons in PHENIX: Au + Au collisions

Au + Au (PRC 79, 81 034911(2010))

partN0 50 100 150 200 250 300 350

)-8

(10

coll

Yie

ld/N

0

2

4

6

8

10

12

14

16

18

20

= 200 GeVNN

sAu+Au

coll)/ N

2<2.8 GeV/c

eeYield (1.2<m

p+p

Au+Au

PYTHIA

crandom c

Strong enhancement of e+e− pairs at low masses:(4.7± 0.4(stat)± 1.5(sys)± 0.9(model)µb (0.15 ≤ me+e− ≤ 0.75GeVc2)Characteristic properties:

- Enhancement down to very low masses- Enhancement concentrated in central collisions- No enhancement in the IMR

Deepali Sharma (Stony Brook University) RHIC/AGS Annual Users’ Meeting 2012 12th June, 2012 10 / 23

Page 13: Dileptons in PHENIX · Dileptons in PHENIX Deepali Sharma for the PHENIX Collaboration Stony Brook University 12th June, 2012 Deepali Sharma (Stony Brook University) RHIC/AGS Annual

Low mass region: evolution with pT

/GeV

)2

(c

ee

dN

/dm

evt

1/N

-610

-510

-410

-310

-210

-110

8.0 GeV/c≤ T

0.0 GeV/c < p

min. bias Au+Au (Run4)

p+p (Run5)

Cocktail p+p2 100 MeV/c≤

eeboth normalized to m

/GeV

)2

(c

ee

dN

/dm

evt

1/N

-610

-510

-410

-310

-210

-110

-1

0.7 GeV/c≤ T

0.0 GeV/c < p

min. bias Au+Au (Run4)

p+p (Run5)

Cocktail p+p2 100 MeV/c≤

eeboth normalized to m

PHENIX Preliminary

-1

)2 (GeV/ceem

0 0.2 0.4 0.6 0.8 1 1.2

/GeV

)2

(c

ee

dN

/dm

evt

1/N

-610

-510

-410

-310

-210

-110

1.5 GeV/c≤ T

0.7 GeV/c < p

min. bias Au+Au (Run4)

p+p (Run5)

Cocktail p+p2 100 MeV/c≤

eeboth normalized to m

PHENIX Preliminary

)2 (GeV/ceem

0 0.2 0.4 0.6 0.8 1 1.2

/GeV

)2

(c

ee

dN

/dm

evt

1/N

-610

-510

-410

-310

-210

-110

)2 (GeV/ceem

0 0.2 0.4 0.6 0.8 1 1.2

-1

8.0 GeV/c≤ T

1.5 GeV/c < p

min. bias Au+Au (Run4)

p+p (Run5)

Cocktail p+p2 100 MeV/c≤

eeboth normalized to m

PHENIX Preliminary

)2 (GeV/ceem

0 0.2 0.4 0.6 0.8 1 1.2

-1

Enhancement mostly at low pT

Deepali Sharma (Stony Brook University) RHIC/AGS Annual Users’ Meeting 2012 12th June, 2012 11 / 23

Page 14: Dileptons in PHENIX · Dileptons in PHENIX Deepali Sharma for the PHENIX Collaboration Stony Brook University 12th June, 2012 Deepali Sharma (Stony Brook University) RHIC/AGS Annual

Comparison to theoretical models (Au + Au)

All models and groups that successfully described the SPS datafail in describing the PHENIX results

Deepali Sharma (Stony Brook University) RHIC/AGS Annual Users’ Meeting 2012 12th June, 2012 12 / 23

Page 15: Dileptons in PHENIX · Dileptons in PHENIX Deepali Sharma for the PHENIX Collaboration Stony Brook University 12th June, 2012 Deepali Sharma (Stony Brook University) RHIC/AGS Annual

Au + Au and Cu + Cu

Au + Au (PRC 79, 81 034911(2010))Npart = 109

Cu + Cu (0-10%)Npart = 98

Deepali Sharma (Stony Brook University) RHIC/AGS Annual Users’ Meeting 2012 12th June, 2012 13 / 23

Page 16: Dileptons in PHENIX · Dileptons in PHENIX Deepali Sharma for the PHENIX Collaboration Stony Brook University 12th June, 2012 Deepali Sharma (Stony Brook University) RHIC/AGS Annual

Centrality dependence of yields across different systemsordered by Ncoll

Deepali Sharma (Stony Brook University) RHIC/AGS Annual Users’ Meeting 2012 12th June, 2012 14 / 23

Page 17: Dileptons in PHENIX · Dileptons in PHENIX Deepali Sharma for the PHENIX Collaboration Stony Brook University 12th June, 2012 Deepali Sharma (Stony Brook University) RHIC/AGS Annual

Centrality dependence of yields across different systemsordered by Ncoll

Enhancement in low mass region is a strong function of centrality.

Enhancement seen in both Cu + Cu and Au + Au systems.

No excess is seen in d + Au

Deepali Sharma (Stony Brook University) RHIC/AGS Annual Users’ Meeting 2012 12th June, 2012 14 / 23

Page 18: Dileptons in PHENIX · Dileptons in PHENIX Deepali Sharma for the PHENIX Collaboration Stony Brook University 12th June, 2012 Deepali Sharma (Stony Brook University) RHIC/AGS Annual

Near future

Deepali Sharma (Stony Brook University) RHIC/AGS Annual Users’ Meeting 2012 12th June, 2012 15 / 23

Page 19: Dileptons in PHENIX · Dileptons in PHENIX Deepali Sharma for the PHENIX Collaboration Stony Brook University 12th June, 2012 Deepali Sharma (Stony Brook University) RHIC/AGS Annual

The future: Hadron Blind Detector

)2 (GeV/ceem

0 0.5 1 1.5 2 2.5 3 3.5 4

/5 M

eV

)2

(c

evt

counts

/N

-1010

-910

-810

-710

-610

-510

-410

= 200 GeVNN

smin. bias Au+Au )

+- pairs (N-e+all e

)comb

+-combinatorial background (B

)+-

signal (S

signal from converter runs

)2

(GeV/ceem0 0.5 1 1.5 2 2.5 3 3.5 4 4.5

+-

/B+

-S

-310

-210

-110

1

10

210

The present PHENIX results suffer from large systematic uncertainties.

The S/B ratio in Au + Au (Run4) is ∼ 1/200 at mass me+e− ≈ 500 MeV/2.

A Hadron Blind Detector was installed in 2009 to improve measurements in the LMR byreducing the combinatorial background.

- use opening angle cut to reject Dalitz decays and conversion pairs

Deepali Sharma (Stony Brook University) RHIC/AGS Annual Users’ Meeting 2012 12th June, 2012 16 / 23

Page 20: Dileptons in PHENIX · Dileptons in PHENIX Deepali Sharma for the PHENIX Collaboration Stony Brook University 12th June, 2012 Deepali Sharma (Stony Brook University) RHIC/AGS Annual

The future: Hadron Blind Detector

)2 (GeV/ceem

0 0.5 1 1.5 2 2.5 3 3.5 4

/5 M

eV

)2

(c

evt

counts

/N

-1010

-910

-810

-710

-610

-510

-410

= 200 GeVNN

smin. bias Au+Au )

+- pairs (N-e+all e

)comb

+-combinatorial background (B

)+-

signal (S

signal from converter runs

)2

(GeV/ceem0 0.5 1 1.5 2 2.5 3 3.5 4 4.5

+-

/B+

-S

-310

-210

-110

1

10

210

The present PHENIX results suffer from large systematic uncertainties.

The S/B ratio in Au + Au (Run4) is ∼ 1/200 at mass me+e− ≈ 500 MeV/2.

A Hadron Blind Detector was installed in 2009 to improve measurements in the LMR byreducing the combinatorial background.

- use opening angle cut to reject Dalitz decays and conversion pairs

Deepali Sharma (Stony Brook University) RHIC/AGS Annual Users’ Meeting 2012 12th June, 2012 16 / 23

Page 21: Dileptons in PHENIX · Dileptons in PHENIX Deepali Sharma for the PHENIX Collaboration Stony Brook University 12th June, 2012 Deepali Sharma (Stony Brook University) RHIC/AGS Annual

Present status of analysis with HBD

p + p

]2 [GeV/c-e+em0 0.5 1 1.5 2 2.5 3 3.5

-110

1

10

210

310

410

510

610

h1_mass_Su_varbinEntries 54Mean 0.01184RMS 0.06811

Mass of the pair

h1_mass_Su_varbinEntries 54Mean 0.01184RMS 0.06811

h1_mass_Su_varbinEntries 54Mean 0.01184RMS 0.06811

h1_mass_Su_varbinEntries 54Mean 0.01184RMS 0.06811

h1_mass_Su_varbinEntries 54Mean 0.01184RMS 0.06811

Au + Au (40-100%)

Uncorrected mass spectra in p + p and Au + Au with HBD

Both analyses are expected to finish by QM

Deepali Sharma (Stony Brook University) RHIC/AGS Annual Users’ Meeting 2012 12th June, 2012 17 / 23

Page 22: Dileptons in PHENIX · Dileptons in PHENIX Deepali Sharma for the PHENIX Collaboration Stony Brook University 12th June, 2012 Deepali Sharma (Stony Brook University) RHIC/AGS Annual

Summary

p + p and d + AuBoth p + p and d + Au results are well described by the cocktail.

No cold matter effects are seen in d + Au.

Au + Au and Cu + CuThe low-mass region in Au + Au shows an enhancement above the cocktail expectations:4.7± 0.4(stat)± 1.5(sys)± 0.9(model)

Theory models fail to describe the data.

Enhancement is seen in Cu + Cu also.

Future: HBD analysisAnalysis of the data with HBD will provide a better precision measurement for the LMR.Results of this analysis are expected soon.

Deepali Sharma (Stony Brook University) RHIC/AGS Annual Users’ Meeting 2012 12th June, 2012 18 / 23

Page 23: Dileptons in PHENIX · Dileptons in PHENIX Deepali Sharma for the PHENIX Collaboration Stony Brook University 12th June, 2012 Deepali Sharma (Stony Brook University) RHIC/AGS Annual

Back-ups

Deepali Sharma (Stony Brook University) RHIC/AGS Annual Users’ Meeting 2012 12th June, 2012 19 / 23

Page 24: Dileptons in PHENIX · Dileptons in PHENIX Deepali Sharma for the PHENIX Collaboration Stony Brook University 12th June, 2012 Deepali Sharma (Stony Brook University) RHIC/AGS Annual

Star p + p dilepton data

Deepali Sharma (Stony Brook University) RHIC/AGS Annual Users’ Meeting 2012 12th June, 2012 20 / 23

Page 25: Dileptons in PHENIX · Dileptons in PHENIX Deepali Sharma for the PHENIX Collaboration Stony Brook University 12th June, 2012 Deepali Sharma (Stony Brook University) RHIC/AGS Annual

Star p + p dilepton data

Deepali Sharma (Stony Brook University) RHIC/AGS Annual Users’ Meeting 2012 12th June, 2012 21 / 23

Page 26: Dileptons in PHENIX · Dileptons in PHENIX Deepali Sharma for the PHENIX Collaboration Stony Brook University 12th June, 2012 Deepali Sharma (Stony Brook University) RHIC/AGS Annual

Hadron Blind Detector - the conceptHBD concept

Windowless Cherenkov detector (L=50cm)

CF4 as the radiator and detector gas.

Proximity focus: detect circular blob and not ring.

Detector Element

Triple GEM stack with pad readout.

Reflective CsI photocathode evaporated on the top face of top GEM.

This scheme exhibits a number of attractive features:

A large N0 ≈ 800 cm−1 (ideal detector with no losses), due to a large bandwidth (from∼ 6 eV given by the CsI threshold to ∼ 11.5 eV given by the CF4 cut off).

No photon feedback due to reflective photocathode.

Hexagonal pads with size (area = 6.2 mm2) comparable to Cherenkov blob size (10.2cm2), that results a single pad hit for hadrons, as compared to 2-3 pads per electron hit.

Low granularity detector (∼ 1000 pads per central arm acceptance).

Primary charge of 5-10 e/pad leads to a moderate gain of 5000. This is a crucialadvantage for the stable operation of a UV photon detector.

Deepali Sharma (Stony Brook University) RHIC/AGS Annual Users’ Meeting 2012 12th June, 2012 22 / 23

Page 27: Dileptons in PHENIX · Dileptons in PHENIX Deepali Sharma for the PHENIX Collaboration Stony Brook University 12th June, 2012 Deepali Sharma (Stony Brook University) RHIC/AGS Annual

Hadron Blind Detector - the conceptHBD concept

Windowless Cherenkov detector (L=50cm)

CF4 as the radiator and detector gas.

Proximity focus: detect circular blob and not ring.

Detector Element

Triple GEM stack with pad readout.

Reflective CsI photocathode evaporated on the top face of top GEM.

This scheme exhibits a number of attractive features:

A large N0 ≈ 800 cm−1 (ideal detector with no losses), due to a large bandwidth (from∼ 6 eV given by the CsI threshold to ∼ 11.5 eV given by the CF4 cut off).

No photon feedback due to reflective photocathode.

Hexagonal pads with size (area = 6.2 mm2) comparable to Cherenkov blob size (10.2cm2), that results a single pad hit for hadrons, as compared to 2-3 pads per electron hit.

Low granularity detector (∼ 1000 pads per central arm acceptance).

Primary charge of 5-10 e/pad leads to a moderate gain of 5000. This is a crucialadvantage for the stable operation of a UV photon detector.

Deepali Sharma (Stony Brook University) RHIC/AGS Annual Users’ Meeting 2012 12th June, 2012 22 / 23

Page 28: Dileptons in PHENIX · Dileptons in PHENIX Deepali Sharma for the PHENIX Collaboration Stony Brook University 12th June, 2012 Deepali Sharma (Stony Brook University) RHIC/AGS Annual

Hadron Blind Detector - the design

The Detector was designed and built at the Weizmann Institute.Two identical arms, with each arm equipped with 12 (23×27 cm2) triple GEM stacks. Each GEM stack iscomprised of a mesh electrode, a top gold plated GEM for CsI and two standard Cu GEMs, and a padelectrode.Kapton foil readout plane: one continuous sheet per side with 1152 hexagonal pads. Also serves as a gasseal, leak rate is 0.12 cc/min.Low material budget: total < 3% X0 (back plane electronics ∼ 1.5%, vessel ∼ 0.92%, gas ∼ 0.54%).∼ 350 gluing operations per arm.

Deepali Sharma (Stony Brook University) RHIC/AGS Annual Users’ Meeting 2012 12th June, 2012 23 / 23