ROOF JACK, MATCH ROOF COLOR
ROOF TOP UNIT
REVOLUTIONS PER MINUTE
SUPPLY AIR FAN
RJ
RPM
RTU
SAF
STATIC PRESSURESP
TCC
TSP TOTAL STATIC PRESSURE
WALL CAPWC
WALK IN COOLERWIC
WALK IN FREEZERWIF
ET EXPANSION TANK
ELECTRIC WATER COOLEREWC
TMV THERMOSTATIC MIXING VALVE
AFF ABOVE FINISH FLOOR
URINAL
SK SINK
MOP SINK
WATER CLOSET
WATER HEATER
CO CLEAN OUT
PLUMBING CONTRACTOR
STORM DRAIN
VENT THROUGH ROOF
SANITARY SEWER
ST STORAGE TANK
SD
SAN
CW COLD WATER DOMESTIC
PC
PRV
PSI
PRESSURE RELEIF VALVE
POUNDS PER SQUARE INCH
MS
LAV LAVATORY
HWS
HWR HOT WATER RETURN DOMESTIC
HOT WATER SUPPLY DOMESTIC
GPM GALLONS PER MINUTE
WH
GC GENERAL CONTRACTOR
VTR
UR
WC
FOOTFT
INCHIN
LEAVING AIR TEMPERATURE
LINEAR SLOT DIFFUSER
MANUAL
LAT
IR
MAN
LS
1000 BTUH
MECHANICAL CONTRACTOR
MOTOR CONTROL CENTER
MBH
MC
MCC
MFR MANUFACTURER
PRESSURE DROP
POOL DEHUMIDIFICATION UNIT
PACKAGE TERMINAL AIR CONDITIONER
POUNDS PER SQUARE INCH
PRESSURE RELEIF VALVE
PD
PDU
PTAC
PSI
PRV
INFRA-RED
AIR HANDLING UNIT
ACCU
AHU
BOTTOM OF DUCT
BACKDRAFT DAMPER
BOD
BDD
COMBUSTION AIR
CUBIC FEET PER MINUTE
CA
CFM
AIR COOLED CONDENSING UNIT
ENTERING AIR WET BULB
ENTERING AIR DRY BULB
DIAMETER
EAWB
EADB
Ø
DRY BULBDB
ELECTRICAL CONTRACTOR
EC
ELECTRIC WALL HEATER
EXHAUST FAN
EF
EWH
HOOD
EXTERNAL STATIC PRESSURE
ELECTRIC REHEAT COIL
H
ESP
ERC
E EXHAUST GRILLE OR REGISTER
FURNACE
FCU
F
FIRE DAMPER OR FLOOR DRAIN
FIRE AND SMOKE DAMPER
FD
FD/SD
FEET PER MINUTEFPM
FAN COIL UNIT
ABBREVIATIONS
UNLESS OTHERWISE NOTEDUON
TEMPERATURE CONTROL CONTRACTOR
REDUCED PRESSURE ZONED BACKFLOWRPZB
FSK FOIL SCRIM VAPOR BARRIER
RETURN AIRRA
SUPPLY AIRSA
EXHAUST AIR OR EACHEA
OUTSIDE AIROA
VARIABLE AIR VOLUME BOXVAV
FAN POWERED VAV BOXFPVAV
DEGREES FARENHEITDEG F
CND
HW
HWR
SD
SAN
RD
PIPING LINETYPES
CONDENSATE DRAIN
HEATING WATER SUPPLY DOMESTIC
HEATING WATER RETURN DOMESTIC
STORM DRAIN
SANITARY SEWER
COLD WATER DOMESTIC
ROOF DRAIN
SYMBOLS
COMPRESSED AIR
CW
CA
GREASE/OIL/DIRT DRAIN LINE GL
GASGAS NATURAL OR PROPANE
ANCHOR / HANGER
BALL VALVE
BUTTERFLY VALVE
EXPANSION JOINT
GATE VALVE
GLOBE VALVE
GAS METER
PIPE GUIDE
"P" TRAP
TEST PLUG
PLUG VALVE
WATER METER
UNION
THERMOMETER
"Y" STRAINER
PRESSURE GAUGE
BALANCING VALVE
CHECK, SWING VALVE
FLEXIBLE PUMP CONNECTION
FLANGED CONNECTION
DROP
PITCH DOWN IN DIRECTION OF ARROW
RUN OUT OFF BOTTOM OF MAIN
RUN OUT OFF TOP OF MAIN
RISER
TEE OFF SIDE OF MAIN
PIPING SYMBOLS
M
GM
P
PENDANT STYLE FIRE SUPPRESSION HEAD
PLUMBING SPECIFICATIONS
DIM
EN
SIO
NS
O
I
H
O
F
E
T
A
T
S
PR
O
F
E
S
S
I
O
N
A
L
E
N
G
I
N
E
E
R
TS
G
I
R
E
E
GOODERUM
O
DAVID R.
74178
R
E
D
GENERAL
1. BID INSTRUCTIONS: CONTRACTORS SHALL PROVIDE
BASE BID IN STRICT ACCORDANCE WITH DESIGN
BASIS EQUIPMENT AND MATERIALS. PROJECT DOES
ENCOURAGE COMPETITIVE PRICING AND ALLOWS
FOR SUBSTITUTIONS OF EQUIPMENT AND
MATERIALS AS ALTERNATE DEDUCTS TO BASIS OF
DESIGN BIDS. LIST ALL SUBSTITUTIONS ALONG WITH
DEDUCTS OFFERED ON BID. OWNER RESERVES THE
RIGHT TO REJECT SUBSTITUTIONS FOUND NOT TO
BE EQUAL TO ITEMS LISTED IN DESIGN BASIS.
2. PRIOR TO PROCUREMENT CONTRACTOR SHALL
SUBMIT TO ARCHITECT FULL SUBMITTALS FOR ALL
ENERGY CONSUMING OR PRODUCING ITEMS AND
FOR ALL PLUMBING FIXTURES, VALVES, DRAINS,
CLEAN OUTS, PIPING, PIPING ACCESSORIES,
INSULATION AND PIPING HANGERS. SUBMITTALS
SHALL BE DELINEATED WITH TAGS INDICATED ON
PRINTS, CONTRACTORS NAME, PROJECT NAME.
CLEARLY INDICATE ALL MODEL NUMBERS AND ALL
ACCESSORIES AND OPTIONS BEING PROVIDED.
SUBMISSIONS SHALL BE IN PDF FORMAT.ENGINEER
RESERVES THE RIGHT TO REJECT ANY SUBSTITUTE
ITEM.
3. CONTRACTOR SHALL BE RESPONSIBLE TO VISIT THE
SITE TO EXAMINE ALL CONDITIONS THAT MAY IN ANY
WAY AFFECT THE EXECUTION OF HIS WORK. HE
SHALL ALSO EXAMINE THE DRAWINGS AND
SPECIFICATIONS FOR OTHER BRANCHES OF WORK
MAKING REFERENCE TO THEM FOR DETAILS OF
EXISTING BUILDING CONDITIONS. NO EXTRAS WILL
BE ALLOWED FOR FAILURE TO INCLUDE ALL
REQUIRED WORK IN THE BID. CONTRACTOR SHALL
GUARANTEE ALL LABOR AND MATERIALS ENTERING
INTO CONTRACT FOR A PERIOD OF ONE (1) YEAR
FROM DATE OF ACCEPTANCE.
4. THE DRAWINGS IN THIS SECTION ARE
DIAGRAMMATIC AND ARE NOT INTENDED TO DEFINE
EXACT QUANTITIES, LOCATIONS OR CODIFIED
REQUIREMENTS. DRAWINGS SHOW GENERAL INTENT
OF SYSTEMS. P.C. SHALL PROVIDE AND PAY FOR ALL
REQUIRED PERMITS.
5. UPON COMPLETION OF THE PLUMBING
INSTALLATION, DEMONSTRATE TO THE ENGINEER
AND/OR THE OWNER'S SATISFACTION THAT THE
SYSTEMS HAVE BEEN INSTALLED IN ACCORDANCE
WITH THE DRAWINGS, SPECIFICATIONS AND
APPLICABLE CODES. DEMONSTRATE THE DYNAMIC
OPERATION OF EACH SYSTEM. VERIFY PROPER
OPERATION OF EQUIPMENT, FILTERS ARE CLEAN
AND COMPONENTS OF THE SYSTEM ARE INSTALLED
AND ADJUSTED IN FULL ACCORDANCE WITH
MANUFACTURER RECOMMENDATIONS.
6. PLUMBING WORK SHALL BE COMPLETE IN EVERY
DETAIL AND ALL MISCELLANEOUS ITEMS OF
MATERIAL AND LABOR NECESSARY TO COMPLETE
THE WORK DESCRIBED, SHOWN OR REASONABLY
IMPLIED ON DRAWINGS OR SPECIFICATIONS SHALL
BE INCLUDED IN THE CONTRACT. CONTRACTOR
SHALL MAKE MINOR ADJUSTMENTS TO THE WORK
WHERE REQUIRED, WHEN SUCH ADJUSTMENTS ARE
NECESSARY FOR PROPER OPERATION AND WITHIN
THE INTENT OF THE CONTRACT. CONTRACTOR
SHALL GUARANTEE ALL LABOR AND MATERIALS
ENTERING INTO CONTRACT FOR A PERIOD OF ONE
(1) YEAR FROM DATE OF ACCEPTANCE.
7. ALL WORK SHALL BE IN FULL ACCORDANCE WITH
CURRENT OHIO NON-RESIDENTIAL MECHANICAL
CODES. FOR MORE INFORMATION REFERENCE WEB
SITE.
http://www.com.ohio.gov/DICO/bbs/NonResidential
BuildingCodes.aspx#OMC
8. PLUMBING CONTRACTOR SHALL ACCEPT SOLE AND
COMPLETE RESPONSIBILITY FOR CONDITIONS OF
THE JOB SITE, INCLUDING SAFETY OF ALL PERSONS
AND PROPERTY DURING PERFORMANCE OF THE
WORK.
9. PLUMBING CONTRACTOR SHALL VERIFY AND BE
RESPONSIBLE FOR ALL WATER, GAS, STORM AND
SEWER UTILITY ROUGH-INS AND SHALL CONSULT
WITH THE CIVIL PLANS AND WITH LOCAL UTILITY
COMPANY(S) PROVIDING ALL MATERIALS AND LABOR
AND PAYING ALL COSTS NOT BORNE BY THE LOCAL
UTILITY COMPANY(S) FOR INSTALLATION OF
SERVICES INCLUDING SECURING AND PAYING FOR
ALL REQUIRED PERMITS.
10. PLUMBING CONTRACTOR SHALL ENSURE
EMPLOYEES ARE MEETING AND DOCUMENTING ALL
OSHA AND JOB SPECIFIC SAFETY REQUIREMENTS AS
REQUIRED BY LAW AND BY CONTRACT. PERSONAL
PROTECTIVE EQUIPMENT SHALL BE PROVIDED AND
UTILIZED AS REQUIRED. MECHANICAL CONTRACTOR
SHALL PAY ALL FINES LEVIED BY OSHA FOR FAILURE
TO COMPLY WITH OSHA REQUIREMENTS.
11. ALL PLUMBING MATERIALS INSTALLED IN RETURN
AIR PLENUMS SHALL BE INSTALLED OR COVERED
WITH MATERIALS AS REQUIRED TO PROVIDE FLAME
RATING OF NOT MORE THAN 25 AND A SMOKE
DEVELOPED INDEX OF NOT MORE THAN 50. PRIOR
TO ROUGH-IN CONSULT WITH M.C. TO VERIFY ALL
LOCATIONS OF RETURN AIR PLENUMS.
12. FURNISH AND INSTALL ACCESS PANELS FOR ALL
CONCEALED EQUIPMENT, PIPING VALVES,
CLEANOUTS, ETC. ACCESS PANELS SHALL BE OF
SUFFICIENT SIZE TO PROVIDE ADEQUATE WORKING
CLEARANCE AND ACCESS.
13. PLUMBING CONTRACTOR SHALL BE RESPONSIBLE
FOR ALL REQUIRED CUTTING AND PATCHING
INCLUDING SAW CUTTING AND PATCHING OF
EXISTING FLOORS AS REQUIRED TO ACCEPT NEW
FLOORING.
EQUIPMENT
1. PROVIDE EQUIPMENT AS SHOWN ON EQUIPMENT
SCHEDULES AND PLAN NOTES. SUBSTITUTIONS TO
LISTED EQUIPMENT SHALL BE AT RISK OF
CONTRACTOR. SUBSTITUTIONS SHALL ONLY BE
ALLOWED IF ITEMS ARE EQUAL IN ALL ASPECTS.
2. PROVIDE SUBMITTALS TO ELECTRICIAN AS
REQUIRED FOR COORDINATION OF ALL REQUIRED
ELECTRICAL POWER WIRING. INCLUDE WIRING
DIAGRAMS AND CABLING REQUIREMENTS FOR
REFERENCE. COORDINATE ALL INTERLOCKS AS
NEEDED. PROVIDE SINGLE POINT CONNECTION KITS
AS NEEDED.
3. INSTALL ALL EQUIPMENT IN FULL ACCORDANCE
WITH MANUFACTURERS RECOMMENDATIONS AND
CLEARANCE REQUIREMENTS. PROVIDE ALL
REQUIRED MOUNTING OR HOUSEKEEPING PADS.
G.C. SHALL PROVIDE LEVEL GRADE FOR EXTERIOR
MOUNTED EQUIPMENT. P.C. SHALL PROVIDE ALL
HOISTING AND RIGGING NEEDED TO SET ALL
PLUMBING EQUIPMENT.
4. ALL EQUIPMENT SHALL BE INSTALLED AS NEEDED
TO PREVENT OBJECTIONABLE NOISE AND/OR
VIBRATION. P.C. SHALL PROVIDE VIBRATION PADS,
SPRING ISOLATORS, ATTENUATORS AND
ACCESSORIES AS NEEDED.
5. PROVIDE ALL BLOCKING, HANGERS, SHELVES,
BRACKETS ETC. AS REQUIRED TO INSTALL ALL
PLUMBING EQUIPMENT.
2. INSTALL WATER HEATERS IN ACCORDANCE WITH
NFPA-70, AND THE NATIONAL ELECTRICAL CODE.
PROVIDE BRASS DRAIN VALVE, 3/4" RELIEF VALVE
AND COLD WATER DIP TUBE. INSTALL HEATERS PER
MANUFACTURES INSTALLATION INSTRUCTIONS.
PROVIDE SHUT-OFF VALVES FOR SERVICE WORK.
3. THERMOSTATS ON WATER HEATER SHALL NOT BE
USED FOR LIMITING HOT WATER TEMPERATURES.
P.C. SHALL PROVIDE MIXING VALVES FOR HOT
WATER TO ALL FAUCETS ACCESSIBLE TO
OCCUPANTS. MIXING VALVE SYSTEMS SHALL LIMIT
WATER TEMPERATURE AT FAUCETS TO 110 DEG F.
OR LESS.
4. PROVIDE SCHEDULE 40 PVC PIPING AND FITTINGS
FOR ALL COMBUSTION AIR AND VENT PIPING IN
ACCORDANCE WITH MANUFACTURERS
INSTRUCTIONS ON ALL DIRECT VENT WATER
HEATERS OR BOILERS.
FIXTURES
1. REFERENCE FIXTURE SCHEDULES ON PLANS AND
PROVIDE ALL REQUIRED CARRIERS, BLOCKING,
HANGERS, TAIL PIECES, TRAPS, RISERS,
ESCUTCHEONS, GRIDS, PUTTY, GASKETS, CAULKING,
ETC. AS REQUIRED TO INSTALL ALL PLUMBING
FIXTURES.
2. REVIEW SUBMITTALS FOR ALL OWNER PROVIDED
EQUIPMENT AND PROVIDE ANY REQUIRED
ACCESSORIES AS NEEDED FOR A COMPLETE
INSTALLATION. P.C. SHALL BE RESPONSIBLE TO
RECEIVE AND INSTALL ALL OWNER PROVIDED
FIXTURES.
2. FIXTURES DESIGNATED FOR HANDICAP
ACCESSIBILITY SHALL COMPLY WITH ANSI A 117.1,
LATEST EDITION, INCLUDING ADOPTED OHIO
AMENDMENTS.
3. PROVIDE ALL CODE REQUIRED BACKFLOW DEVICES
FOR PROCESS HVAC EQUIPMENT AND FOR WATER
SERVING ANY DRINKING OR FOOD PREPARATION
FIXTURES.
4. PROVIDE BELLOWS TYPE WATER HAMMER
ARRESTERS, STAINLESS STEEL CASHING AND
BELLOWS, 250 PSI, INSTALL PER PDI STANDARD
WH201.
PIPING
1. ALL EXPOSED SUPPLY PIPES AND METAL TRIM IN
CONNECTION WITH THE FIXTURES SHALL BE
CHROME PLATED RED BRASS OR BRONZE, PROVIDE
CHROME PLATED STOP VALVES IN ALL SUPPLIES TO
ALL FIXTURES. PLASTIC STOPS OR TRIM SHALL NOT
BE ACCEPTABLE. CAULK ALL FIXTURES WITH
WATERPROOF SILICONE CAULK. TRAPS SHALL HAVE
CLEANOUT PLUGS. INSTALL ONE PIECE CHROME
ESCUTCHEON PLATE AT WALL PENETRATIONS.
2. WASTE AND VENT PIPING MAINS SHALL BE PITCHED
AT 1/8" PER FOOT. LATERAL BRANCHES SHALL BE
PITCHED 1/4" PER FOOT TOWARD THE SANITARY
SEWER MAIN. THEY SHALL BE INSTALLED AND
TESTED IN ACCORDANCE WITH THE CURRENT
PLUMBING CODE AND TESTED PER AUTHORITY
HAVING JURISDICTION.
3. VERIFY LOCATION, DEPTH AND SIZE OF SANITARY
SEWER CONNECTION POINTS. CONNECT AS
REQUIRED. OUTSIDE SEWER SHALL BE INSTALLED
PER MUNICIPAL CODE. COORDINATE CONNECTIONS
WITH SITE CONTRACTOR AND LOCAL UTILITY
4. ALL OUTSIDE WATER PIPING SHALL BE COVERED
PER LOCAL REQUIREMENTS.
5. ALL INTERIOR PIPING PENETRATIONS THROUGH
WALLS, CEILINGS, ROOFS AND FLOORS SHALL BE
SLEEVED AND SEALED. PROVIDE UL LISTED FIRE
STOPPING WHERE REQUIRED.
6. ALL EXTERIOR UNDERGROUND PENETRATIONS OF
BUILDING FOUNDATIONS OR SLAB FLOORS SHALL BE
SLEEVED AND SEALED. PENETRATIONS BELOW
GRADE INTO BUILDING SPACES SHALL BE DONE
WITH MECHANICAL SEALS LIKE "LINK SEAL" OR
EQUAL.
7. NO PLUMBING PIPING SHALL PASS DIRECTLY OVER
ELECTRICAL PANELS OR DISTRIBUTION CABINETS.
PRIOR TO ROUGH IN COORDINATE WITH E.C.
8. DIELECTRIC UNIONS SHALL BE USED TO CONNECT
DISSIMILAR METALS OR METAL PIPING SHALL HAVE
METAL CONNECTIONS ON EACH END THREADED TO
MATCH THE ADJACENT PIPING. METAL
COMPONENTS SHALL BE SEPARATED BY A NYLON
INSULATOR TO PREVENT CURRENT FLOW BETWEEN
DISSIMILAR METALS. UNIONS SHALL BE SUITABLE
FOR THE SYSTEM OPERATING PRESSURES AND
TEMPERATURE WELD TYPE: ASTM A-234.
9. PIPING SLEEVES; INTERIOR OR EXTERIOR ABOVE
GRADE; GALVANIZED-STEEL-PIPE SLEEVES OR
PVC-PIPE SLEEVES. VERIFY, WITH FIRE AUTHORITIES
HAVING JURISDICTION, THAT PVC MATERIALS ARE
ALLOWED FOR SLEEVES. BELOW GRADE; ALL;
MECHANICAL GALVANIZED-STEEL PIPE SLEEVE
SYSTEM LIKE LINK-SEAL. ALL SLEEVES SHALL BE
FIRE STOPPED OR CAULKED. EXTERIOR SLEEVES
SHALL PROVIDE WATER/AIR TIGHT PENETRATION
SYSTEM.
10. PROVIDE HANGERS PER MSS AND IPC STANDARDS
BASED ON PIPING TYPES AND SIZES.
11. PIPING MATERIALS UNLESS OTHERWISE NOTED ON
THE PLANS SHALL BE AS FOLLOWS:
GAS ABOVE GRADE, 2" AND SMALLER; BLACK
STEEL SCHEDULE 40 TYPE E OR S PIPE
GRADE B; ASTM A53 / A53M, A105 OR A120
WITH THREADED ENDS; FITTINGS SHALL
BE MALLEABLE IRON THREADED FITTINGS
ASTM B16.3 CLASS 150.
ABOVE GRADE 2-1/2" AND LARGER: BLACK
STEEL SCHEDULE 40 TYPE E OR S PIPE
GRADE B; ASTM A53 / A53M, A105 OR A120
WITH PLAIN ENDS. FITTINGS; WROUGHT
STEEL WELDING FITTINGS TO ASTM A
234/A 234M FOR BUTT AND SOCKET
WELDING.
PROVIDE AND INSTALL VENTLESS GAS
REGULATORS LIKE MAXITROL 325 SERIES
TO REGULATE 2 PSIG DISTRIBUTION
PRESSURE TO APPLIANCE REQUIRED
PRESSURE AND FLOWS PER
MANUFACTURERS RECOMMENDATIONS.
PROVIDE AND INSTALL BRASS VALVE TAGS
ON ALL REGULATORS STAMPED WITH THE
SET PRESSURE AS DICTATED BY THE
APPLIANCE MANUFACTURER.
P.C. SHALL ENSURE ALL EXTERIOR ABOVE
GRADE METALLIC PIPING SHALL BE
PROTECTED AGAINST CORROSION BY
PAINTED IN AN APPROVED MANNER WITH
AN ALKYD/OIL BASE YELLOW PAINT.
WATER BELOW GRADE : ALL PIPING SHALL BE
COPPER TUBING (BELOW SLABS AND
EXTERIOR): ASTM B 88 TYPE 'K' SOFT
WATER TUBE ANNEAL TEMPERED. NO
JOINTS PERMITTED BELOW GROUND.
WATER IN WATER SERVICE ROOM AND WATER
HEATER ROOM ALL PIPING SHALL BE
COPPER TUBING ASTM B 88, TYPE 'L' HARD
WATER TUBE DRAWN TEMPER. WITH
CAST-COPPER SOLDER-JOINT FITTINGS:
ANSI B16.18. OR WROUGHT-COPPER
SOLDER JOINT FITTINGS: ANSI B16.22
WATER PEX WATER PIPING (TYPICAL ROOM UNITS)
SHALL BE WIRSBO OR UPONOR TUBING
ASTM F876 AND F877, BLUE FOR COLD AND
RED FOR HOT AND RE-CIRCULATION.
FITTINGS SHALL BE UPONOR ProPEX
SYSTEM C69300 BRASS FITTINGS ASTM
F877, F1960. MANIFOLDS: ProPEX TYPE L
TO ASTM F877 WITH BRASS BALL VALVES.
WATER RISERS AND MAINS LOCATED ABOVE
CEILINGS AND OUTSIDE OF SERVICE ROOM
AND HOT WATER HEATER ROOM. FLOW
GUARD GOLD - EQUAL SDR 11 CPVC;
PIPING ASTM D 2846 WITH SOCKET
WELDED FITTINGS ASTM F 493. MADE
FROM CPVC CELL CLASS 24448 ASTM D
1784. MANUFACTURED PER NSF 14 AND 61.
SEWER POLYVINYL CHLORIDE SEWER PIPE (PVC):
ASTM D2665 SOLID DRAIN WASTE AND
VENT OR ASTM F 891 CELLULAR CORE
SCHEDULE 40 WITH PVC SOCKET WELDED
FITTINGS DESIGNED TO FIT PIPING
DIAMETERS. INSULATED IN RETURN AIR
PLENUMS.
CONDENSATE COPPER DRAIN, WASTE AND VENT PIPE
MINIMUM SIZE 3/4" . INSULATED IN RETURN
AIR PLENUMS.
STORM LATERALS
POLYVINYL CHLORIDE SEWER PIPE (PVC):
ASTM D2665 SOLID DRAIN WASTE AND
VENT OR ASTM F 891 CELLULAR CORE
SCHEDULE 40 WITH PVC SOCKET WELDED
FITTINGS DESIGNED TO FIT PIPING
DIAMETERS. INSULATED IN RETURN AIR
PLENUMS.
STORM RISERS SAME AS STORM LATERALS.
PLUMBING INSULATION
1. ALL PIPING INSULATION MATERIALS SHALL HAVE A
FLAME SPREAD RATING OF 25 OR LESS (ON THE
FLAME SPREAD TEST SCALE) AND SMOKE
DEVELOPMENT OF 50 OR LESS (ON THE SMOKE TEST
SCALE) OR AS DEFINED BY NFPA 255 STANDARD
METHOD OF TESTING OF SURFACE BURNING
CHARACTERISTICS OF BUILDING MATERIALS, LOCAL
CODES AND LOCAL AUTHORITIES HAVING
JURISDICTION. ALL PVC PIPING LOCATED IN RETURN
AIR PLENUM SPACES OR EXPOSED SHALL BE
INSULATED.
2. INSULATION: INSTALL ALL INSULATION REQUIRED BY
THE OHIO ENERGY CODE IN STRICT ACCORDANCE
WITH MANUFACTURERS INSTRUCTIONS , IN A TIGHT
AND NEAT MANOR. NO SAGGING, FRAYED OR TORN
INSULATION WILL BE EXCEPTED. UNLESS
OTHERWISE NOTED ON PLANS. PIPING SHALL BE
INSULATED AS FOLLOWS:
ALL COPPER CW AND ALL HW LINES
SHALL BE INSULATED TO THE FOLLOWING
THICKNESS.
a. HW: 1/2" THICKNESS FOR PIPE SIZES
UP TO 1-1/2", 1" THICKNESS FOR
GREATER THAN 1-1/2.
b. CW: 1/2" THICKNESS FOR PIPE SIZES.
MATERIAL CHOICES SHALL INCLUDE:
PRE-FORMED TYPE I, 850 DEG F MINERAL
OR GLASS FIBERS BONDED WITH A
THERMOSETTING RESIN AND HINGED WITH
SELF SEALING LAP. COMPLY WITH
ASTM C 547, TYPE I, GRADE A, WITH
FACTORY-APPLIED ASJ.
FLEXIBLE ELASTOMERIC CLOSED CELL OR
EXPANDED RUBBER PIPE INSULATION
WITH PRESSURE SENSITIVE ADHESIVE
SYSTEM, ASTM C534, ASTM E84 CLASS A
300 DEG F.
EXTERIOR EXPOSED INSULATION SHALL
BE JACKETED WITH UV RESISTANT PVC
PIPE JACKETS AND PREFORMED FITTING
COVERS COMPLIANT WITH ASTM D257,
D638, D790, D792, D1784, D3679, E84 AND
E136.
CHECK TEST AND START UP REQUIREMENTS
1. CLOSE OUT: PROVIDE MANUFACTURERS OPERATION
AND MAINTENANCE MANUALS AND AS BUILT
DRAWINGS. PROVIDE (1) TRAINING SESSION TO
OWNER SELECTED PERSONNEL AS REQUESTED AND
PROVIDE WARRANTY INFORMATION FOR ALL
MANUFACTURERS WARRANTED EQUIPMENT.
2. FILL SYSTEMS WITH FRESH WATER AND INSPECT
ALL CONNECTIONS FOR LEAKAGE. REMOVE ALL
PACKING AND PROTECTIVE SHIPPING MATERIALS.
CLEAN ALL FIXTURES AND START-UP ALL WATER
HEATERS, PUMPS, AND EQUIPMENT. VERIFY PROPER
OPERATION. OPERATE ALL FAUCETS AND INSPECT
STOPS, RISERS, TRAPS AND DRAINS. CORRECT ALL
LEAKS, WATER HAMMER AND VIBRATIONS AS
REQUIRED.
SCHEDULES OF THROUGH PENETRATION FIRESTOP SYSTEMSCONCRETE FLOORS CONCRETE OR BLOCK WALLS
TYPE OF PENETRANTF-RATING
(HR)UL-CLASSIFIED
SYSTEM TYPE OF PENETRANT F-RATING UL-CLASSIFIEDSYSTEM
CIRCULAR BLANKOPENINGS
1 FA 0006,CAJ 0055,CAJ 0090
CIRCULAR BLANKOPENINGS
1 CAJ 0055, CAJ 0090
2 FA 0006,CAJ 0055,CAJ 0090 2 CAJ 0055, CAJ 0090
3 FA 0006, CAJ 0055,CAJ 0086, FA 0014 3 CAJ 0055, CAJ 0086
SINGLE METAL PIPESOR CONDUIT
1 CAJ 1226, FA 1028
SINGLE METAL PIPESOR CONDUIT
1 CAJ 1226, WJ 1067
2 CAJ 1226, FA 1028 2 CAJ 1226, WJ 1067
3 CAJ 1226, FA 1017 3 CAJ 1226, WJ 1041,WJ 1068
4 CBJ 1037, CBJ 1034 4CBJ 1034, CBJ 1037,WJ 1041, WJ 1042,
WJ 1068
SINGLENON-METALLIC PIPE
OR CONDUIT (I.E. PVC,CPVC, ABS, FRP, ENT)
1
FA 2053, FA 2025,CAJ 2109, CAJ 2098,CAJ 2271, CAJ 2167,CBJ 2021, CAJ 2342
SINGLENON-METALLIC PIPE
OR CONDUIT (I.E. PVC,CPVC, ABS, FRP, ENT)
1CAJ 2109, CAJ 2098,CAJ 2167, CAJ 2371,
CAJ 2342
2
FA 2053, FA 2025,CAJ 2109, CAJ 2098,CAJ 2271, CAJ 2167,CBJ-2021, CAJ 2371,
CAJ 2342
2CAJ 2109, CAJ 2098,CAJ 2167, CAJ 2371,
CAJ 2342
3FA 2054, CAJ 2109,
CAJ 2098, CAJ 2371,CAJ 2342
3 CAJ 2109, CAJ 2098,CAJ 2371, CAJ 2342
4 CBJ 2016, CAJ 2017 4 WJ 2057, WJ 2091
SINGLE INSULATEDPIPES
1FA 5015, FA 5017,
CAJ 5090, CAJ 5091,CAJ 5098
SINGLE INSULATEDPIPES
1 CAJ 5090, CAJ 5091,CAJ 5061, WJ 5042
2FA 5015, FA 5017,
CAJ 5090, CAJ 5091,CAJ 5090
2 CAJ 5090, CAJ 5091,CAJ 5061, WJ 5042
3 FA 5016, CAJ 5090,FA 5018 3 CAJ 5090, CAJ 5061
4 CBJ 5006 4 CBJ 5006, WJ 5028
NON-INSULATEDMECHANICAL
DUCTWORK WITHOUTDAMPERS
1 CAJ 7046, CAJ 7051,CAJ 7084 NON-INSULATED
MECHANICALDUCTWORK WITHOUT
DAMPERS
1 CAJ 7046, CAJ 7051,WJ 7021, WJ 7022
2 CAJ 7046, CAJ 7051,CAJ 7084 2 CAJ 7046, CAJ 7051,
WJ 7021, WJ 70223 CAJ 7046, CAJ 7051 3 CAJ 7046, CAJ 7051
INSULATEDMECHANICAL
DUCTWORK WITHOUTDAMPERS
N/A** N/A**
INSULATEDMECHANICAL
DUCTWORK WITHOUTDAMPERS
1 WJ 7029
2 WJ 7029
MIXED PENETRANTS
1 CAJ 8099, CAJ 8056,CAJ 8143
MIXED PENETRANTS
1 CAJ 8099, CAJ 8056,WJ 8007, CAJ 8143
2 CAJ 8099, CAJ 8056,CAJ 8143 2 CAJ 8099, CAJ 8056,
WJ 8007, CAJ 8143
3 CAJ 8099, CAJ 8056 3 CAJ 8041, CAJ 8056,WJ 8007, CAJ 8099
4 CAJ 8095 4 CAJ 8095, WJ 8007
WOOD FLOOR GYPSUM WALLBOARD ASSEMBLIES
TYPE OF PENETRANT F-RATING UL-CLASSIFIEDSYSTEM TYPE OF PENETRANT F-RATING UL-CLASSIFIED
SYSTEM
METAL PIPES ORCONDUIT
1 FC 1009, FC 1059
METAL PIPES ORCONDUIT
1 WL 1054, WL 1058,WL 1164
2 FC 1009, FC 10592 WL 1054, WL 1058,
WL 1164
4 WL 1110, WL 1111,WL 1165
NON-METALLIC PIPEOR CONDUIT
1FC 2232, FC 2030,FC 2160, FC 2127,
FC 2128 NON-METALLIC PIPEOR CONDUIT
1 WL 2078, WL 2075,WL 2128
2FC 2029, FC 2030,FC 2128, FC 2127,
FC 2160
2 WL 2078, WL 2075,WL 2128
4 WL 2184, WL 2245
INSULATED PIPES
1 FC 5004, FC 5037,FC 5036 CABLE TRAY
1 WL 4011, WL 40192 WL 4011, WL 40194 WL 8014
2 FC 5004, FC 5037 INSULATED PIPES
1 WL 5028, WL 5029,WL 5047
2 WL 5028, WL 5029,WL 5047
4 WL 5073NON-INSULATED
MECHANICALDUCTWORK WITHOUT
DAMPERS
1 FC 7013
NON-INSULATEDMECHANICAL
DUCTWORK WITHOUTDAMPERS
1 WL 7017, WL 7040,WL 7042, WL 7155
2 WL 7040, WL 7042,WL 7155
INSULATEDMECHANICAL
DUCTWORK WITHOUTDAMPERS
1 N/A** INSULATEDMECHANICAL
DUCTWORK WITHOUTDAMPERS
1 WL 7059, WL 7153,WL 7156, WL 7151
2 N/A** 2 WL 7059, WL 7153,WL 7156, WL 7151
MIXED PENETRANTS 1 FC 8009, FC 8014,FC 8026, FC8025 MIXED PENETRANTS
1 WL 1095, WL 80132 WL 1095, WL 80134 WL 8014
NOTES:1. Jobsite conditions of each through-penetration firestop system must meet ALL details of the UL-Classified Systemselected.2. Where more than one applicable UL-Classified System is listed in the schedules, choose the UL System which is mosteconomical for each through-penetration firestop system.3. Coordinate work with other trades to assure that penetration opening sizes are appropriate for penetrant locations, andvice versa.
SCHEDULES OF THROUGH PENETRATION FIRESTOP SYSTEMS
NOTES:1. Jobsite conditions of each through-penetration firestop system must meet ALL details of the UL-Classified Systemselected.2. Where more than one applicable UL-Classified System is listed in the schedules, choose the UL System which is mosteconomical for each through-penetration firestop system.3. Coordinate work with other trades to assure that penetration opening sizes are appropriate for penetrant locations, andvice versa.
FIRE PENETRATION SCHEDULE
DIM
EN
SIO
NS
O
I
H
O
F
E
T
A
T
S
PR
O
F
E
S
S
I
O
N
A
L
E
N
G
I
N
E
E
R
TS
G
I
R
E
E
GOODERUM
O
DAVID R.
74178
R
E
D
9
SCALE: N/A
MIXING VALVE DETAIL
SUPPLY INLET
SUPPLY INLET
DIELECTRIC UNION
VALVES RECOMMENDED
SUPPLIED
WATER OUTLET
TEMPERED
HOT SHUT
OFF VALVE
MIXING
VALVE
1-5/8 X 13/16 X 14" L
UNISTRUT
TEMPERATURE
GAUGE
TEMPERATURE
ADJUSTMENT
KNOB
CHECKSTOP
CHECKSTOP
MAX TEMP
SET SCREW
ISOLATION
25±1/4"
[635±6mm]
10
SCALE: N/A
HOT WATER RETURN DETAIL
CHECK VALVE
BALL VALVE
HOT WATER
RETURN
NEXUS UMS AUTOMATIC
FLOW CONTROL VALVE SEE
SCHEDULE FOR GPMS.
HOT WATER
SUPPLY
LAST BRANCH
ON LATERAL
BALL VALVE
FLOW SCHEDULE
SIZE
3/4"FS1
MARK FLOW
2.0
GPM
FS2 1.0
FS3 1.0
FS4 2.0
3/4"
3/4"
3/4"
QTY TOTAL
GPM
12 24.0
1
1
1
1.0
1.0
2.0
INSULATED PLUMBING PIPES.
RIGID MOLDED FIBERGLASS
INSULATION
METAL PROTECTION
SHIELDS
HANGING RODS
1
2
" MIN.
NUTS & LOCK
WASHERS
SUPPORT CHAIR
BOLTED TO CHANNEL
STEEL CHANNEL
ADEQUATE TO
CARRY LOAD
GENERAL NOTES:
1) PROTECTION SADDLES SHALL BE COPPER CLAD IF COPPER TUBE IS USED.
2) PROVIDE INTERMEDIATE HANGING ROD SUPPORT WHERE NUMBER OF
PIPES EXCEED FIVE(5).
TRAPEZE HANGER DETAIL
NO SCALE
5
PIPE
LENGTH OF
SHIELD
8"
12"
LENGTH OF SHIELD
SEE SCHEDULE
PIPE SIZE
1
2
" TO 6"
8" TO 12"
SHIELD SCHEDULE
16 GA. GALV. STEEL SHIELD
ADJUSTABLE CLEVIS HANGER
FIBERGLASS INSULATION
TYPICAL FOR ALL INSULATED
PIPING
ADD PIPE SLEEVE THAT HAS
AN INSIDE DIAMETER,
1
4
"±
LARGER THAN OUTSIDE DIA.
PIPE HANGER ROD CLIP
CONNECTION
TO STRUCT. MEMBER
"L" 6'-0"MAX.
ADD FRAMING CHANNEL
OR ANGLE WHEN "L" IS
GREATER THAN MAX.
LENGTH.
PIPE HANGER
SAME AS
OPPOSITE
SIDE
CLEAN OUT DETAIL
NO SCALE
1
SINGLE PIPE HANGER DETAIL
NO SCALE
8
FLOOR DRAIN
CONCRETE TO PROVIDE
CAP TO BE SET IN
SUITEABLE ANCHORAGE
SYSTEM
TO DOMESTIC
3"
NOT LESS THAN 8"
NOR MORE THAN 24"
DRAIN
INLET
2"
BACKFLOW PREVENTER DETAIL
NOT TO SCALE
2"
3"
SECURE ALL PIPING,
FITTINGS AND VALVES TO
WALL OR FLOOR PER
SPECIFICATIONS.
11
RPZB
RPZB
PLUG
VALVE
1-1/2"
1-1/2"
1-1/2"
1-1/2"
M.J. X FL. ADAPTER
ALL THR. ROD
WASHER
TIE BOLT
"J" BOLT OR
HEX NUT &
THRUST BLOCK
(PER NFPA 24)
U.G. PIPING
GARAGE FLOOR
D.I.P. RISER
4" CONNECTION
3
WATER SERVICE DETAIL
SLEEVE AND SEAL
WALL PENETRATION
(SIZE AS INDICATED
ON DRAWINGS
DISCHARGE PIPE
SCHEDULE 40
PVC W/REDUCER
AIR GAP = 2 X "D" OR 2" MIN.
FIN. FLR.
IN-DIRECT DRAIN CONNECTION
NO SCALE
7
S.S. CLAMPING RING
NON-INSULATED PIPE
SEALANT IN PIPE SLEEVE
URETHANE OR DOW CORNING
1/2" (MIN.) FOAM-IN-PLACE
RESILIENT FOAM PENETR.
#3-6548 SILICONE RTV
NON-INSULATED PIPE
EPDM FLASHING BOOT
WIRE MESH
STAINLESS STEEL
1/4"x1/4"
VENT THRU ROOF DETAIL
NO SCALE
2
SN
OW
L
OA
DIN
G H
GT
. R
QM
TS
.
EX
TE
ND
V
EN
TIN
G P
ER
4
SCALE: N/A
GAS CONNECTION DETAIL
ROOF LINE
MIRO PIPE STAND
ELBOW
ELBOW
UNION
MUA
4" DIRT LEG
WITH CAP
FIELD VERIFY LENGTH
AGA RATED GAS STOP
REGULATOR
12
ELEVATOR PIT DETAIL - WASTE
NO SCALE
6
SCALE: 1/4" = 1'-0"
ROOF DRAIN DETAIL
ROOF DRAIN
J.R. SMITH MODEL 1010Y ROOF
DRAIN NO-HUB WITH DUCO CAST
IRON BODY / FLASHING CLAMP AND
POLYETHYLENE DOME
ROOF GAS PIPING HANGER DETAIL
NO SCALE
13
MIRO #1.5 PIPE SUPPORT
W/ ACCESSORIES
ACCESSORIES
- 1.5 pipe guide
- 1.5 spacer
- Support pad
- Eternabond
} 2-sided tape
WATER HEATER PIPING IS
DIAGRAMATIC, INSTALL ALL
PIPING IN STRICT ACCORDANCE
WITH MANUFACTURERS
RECOMENDATIONS.
PIT LID
ELEVATOR WALL
SUMP PIT
AIR GAP REQD
FIN FLOOR
SUMP PUMP
PIT FLOOR
FD
2"Ø
2"Ø
(SLEEVE AND SEAL PENETRATION)
2"Ø
SP-1
TO ELECTRICAL SUPPLY
OIL SMART SYSTEM
ALARM PANEL
1. COORDINATE ALL WORK WITH ELEVATOR
EQUIPMENT INSTALLER.
2. ALL WORK IN FULL ACCORDANCE WITH OHIO
ELEVATOR CODE, (ASME A17.1-2010).
3. VERIFY LOCATION OF SUMP WITH ELEVATOR
COMPANY
SUMP/PUMP OPTIONS(OR APPROVED EQ)
LIBERTY MODEL 290 ELV OIL TECTOR SYSTEM,
3
4
HP, 115V 100 GPM @ 5' HEAD WITH SXL24-3 NEMA
4X SIMPLEX CONTROL PANEL, BCV150 CHECK
VALVE, XT24BX36 24"X36" FIBERGLASS SUMP AND
XC24P2395 PERFORATED STEEL COVER
ZOELLER MODEL 161 OIL GUARD SYSTEM,
3
4
HP,
115V 100 GPM @ 5' HEAD WITH 10-0126 NEMA 4X
SIMPLEX CONTROL PANEL, 300015 CHECK VALVE,
B24 18"X30" FIBERGLASS SUMP AND PERFORATED
STEEL COVER
NOTES
1-1/4" IRRIG. CONN.
(SEE LANDSCAPE PLANS)
DIM
EN
SIO
NS
O
I
H
O
F
E
T
A
T
S
PR
O
F
E
S
S
I
O
N
A
L
E
N
G
I
N
E
E
R
TS
G
I
R
E
E
GOODERUM
O
DAVID R.
74178
R
E
D
--
--
RPZB
1-1/2"1-1/2"
2"- 1/2" 3"
1/2"1/2"
SEE PLANS
-- -
FD
ITEM
PLUMBING FIXTURE SCHEDULE - PROVIDE HI APPROVED FIXTURE PACKAGEV
(inch)
WHW
(inch) (inch)
CW
(inch)
DESCRIPTION
WC-1H
L-1
SK-1
CO
HORIZONTAL CLEANOUT: SMITH 4020 SERIES CAST IRON BODY WITH ADJUSTABLE ROUND NICKLE BRONZE TOP.
-- -
1/2" 1/2" 3" 2"WC-1
MS
WH1,2,3,4
AMERICAN AMERICAN STANDARD RELIANT 3: 7385.000 RELIANT SINGLE CONTROL CENTERSET
1/2" 1/2" 1-1/2 1-1/2"
ELKAY UNDERMOUNT SINGLE BOWL SINK: ELU129 WITH MOEN 4904 SINGLE HANDLE HIGH ARC BAR FAUCET
1-1/2 1-1/2"
AMERICAN STANDARD: 2386.012 RIGHT HEIGHT CADET3 ELONGATED TOILET 1.6 GPF, 5325.024 RISE AND SHINE
CLOSED FRONT SEAT WITH LID.
ACORN: MOP SINK TDF-24, TERRAZZO WITH CHROME FINISH KFC, MOP HANGER WITH 3 GRIPS ON STAINLESS STEEL WALL BRACKET
KMH.
1/2" 1/2" 3" 1-1/2
-
1-1/2"
WOODFORD Y2 YARD HYDRANT FAUCET, SELF DRAINING, FREEZE PROOF WITH VACUUM BREAKER.
HB
-3/4" -
1-1/2"1/2" -
AO SMITH CYCLONE : BTH 199 GAS 199,999 BTUH 96% THERMAL EFFICIENCY, DIRECT VENT
FLOOR DRAIN: SMITH 2010-A05-NB SERIES CAST IRON BODY WITH FLASHING COLLAR, CONNECTION AND ADJUSTABLE 5" SQUARE
NICKLE BRONZE STRAINER.
REDUCED PRESSURE ZONE BACKFLOW PREVETER: WATTS MODEL 009M2QTS CAST BRONZE CONSTRUCTION WITH QUARTER TURN
FULL-PORT BALL VALVES AND BRONZE STRAINER.
SK-3
ELKAY RNSF8354 THREE COMPARTMENT 18 GAUGE, TYPE 302 STAINLESS STEa SINK W ITH SINGLE FAUCET HOLE ON DECK, 1.5 GPM
AERATOR, MCGUIRE 151A STRAINER, AND MCGUIRE 8912 P-TRAP. INSULATE DRAIN AND WATER UNES WITH "TRUBRO" LAVGUARD2
KIT.
1/2"1/2" 1-1/2 1-1/2"
- -- -
RP
ARMSTRONG H53 BRONZE BODY, CERAMIC THRUST BEARINGS. PLASTIC IMPELLAR, STAINLESS STEEL ROTOT AND SHAFT,
SELF-LUBRICATED GRAPHITE BEARINGS, EPDM DIAPHRAGM 230 F MAX WATER TEMPERATURE. 140 PSI MAX WORKING PRESSURE 20
GPM. 30' TDH.
JR SMITH 1010 WITH CLAMP AND SUMP.
RD-1
AMERICAN STANDARD: 2383.012 CADET ELONGATED TOILET 1.6 GPF, 5325.024 RISE AND SHINE CLOSED FRONT SEAT WITH LID.
2"- 1/2" 3"
WC-2
AMERICAN STANDARD: 2386.012 RIGHT HEIGHT CADET3 ELONGATED TOILET 1.6 GPF, 5901.100 ELONGATED HEAVY
DUTY BOWL OPEN FRONT SEAT LESS COVER. PROVIDE W/ AUTO FLUSH VALVE SYSTEM
L-2
1/2" 1/2" 1-1/2 1-1/2"L-3
1/2" 1/2" 1-1/2 1-1/2"
AMERICAN STANDARD LUCERNE WALL HUNG SINK: 0355.012 4" CENTERS GLAZED WITH AMERICAN STANDARD RELIANT 3: 7385.000
RELIANT SINGLE CONTROL CENTERSET FAUCET
AMERICAN STANDARD OVALYN UNDERCOUNTER SINK: 0495.300 GLAZED WITH AMERICAN STANDARD RELIANT 3: 7385.000 RELIANT
SINGLE CONTROL CENTERSET
SK-2
ELKAY WNSF82422 TWO COMPARTMENT, 18 GAUGE. TYPE 302 STAINLESS STEa SINK W ITH DUAL FAUCET HOLES IN BACKSPLASH, 1.5
GPM AERATOR. MCGUIRE 151A STRAINER. AND MCGUIRE 8912 P-TRAP. INSULATE DRAJN AND WATER UNES WITH TRUBRO"
LAVGUAR02 KIT.
4 21/2 1/2
TB-1
AMERICAN STANDARD NEW SALEM RECESS BATH: 0255 WITH MOEN TL183NH SINGLE-HANDLE TUB/SHOWER TRIM KIT
P.C. TO INSTALL OWNER PROVIDED HIX KOHLER FORTE SHOWER HEAD
4 21/2 1/2
TB-2
4 21/2 1/2
SH-1
SHOWER BASE BY OTHERS WITH MOEN 8346 SINGLE-HANDLE PRESSURE BALANCING SHOWE5R VALVE WITH HAND-HELD SHOWER
SYSTEM
AMERICAN STANDARD RECESS BATH: 0255 WITH MOEN 8346 SINGLE-HANDLE PRESSURE BALANCING SHOWER VALVE WITH
HAND-HELD SHOWER SYSTEM WITH MOEN 3931 DIVERTER SPOUT W/ SEAT AND GRAB BAR
EWS
BRADLEY S192240A1ADAD00 STAINLESS STEEL BOWL. TAILPIECE AND P-TRAP. COMPLETE WITH ANSI STANDARD Z358.1. SUPPLY
AND WASTE PIPES ARE GALVANIZED STEEL PROTECTEO WITH BRADTECT® SAFETY YELLOW COATING. UNIVERSAL IDENTIFICATION
SIGN AND INSPECTION TAG INCLUDED. EYEWASH EXCEEDS MINIMUM WATER FLOW OF 0.4 GPM AT 30 PSI. BARRIER-FREE DESIGN
-FULLY ACCESSIBLE TO PEOPLE WITH PHYSICAL 01SAB1UTIES
4 21/2 1/2
FSSIOUX CHIEF 861-22X FLOOR SINK
4 21/2 1/2
WB WASHER UTILITY BOX WITH AIR HAMMER ARRESTORS AND ELECTRICAL CONNECTION.
4
TD 6'-0" WATTS DEAD LEVEL PRE-SLOPED POLYPROPYLENE TRENCH DRAIN
WS-1,2
SOFTNER SYSTEM AQUA SYSTEM #2900 NT 14 DX SF70 #05010610 24 X 50 BRINE TANK SOLAR SALT 16 BAGS SYSTEM START UP
1/2" 1/2" 1-1/2 1-1/2"
WATER HAMMER ARRESTER SCHEDULEPCN/
FIG. NO.
P.D.I.
SYMBOL RATING
FIXTURE UNIT
SIZE
A B C D
5005
5010
5020
5030
5040
5050
A
B
C
D
E
F
1-11
12-32
33-60
61-113
155-330
114-154
3/4
1
1
1
1
1
3
3-5/8
5-1/8
5-1/2
6-5/8
3-1/4
3-1/4
3-1/4
3-1/4
3-1/4
1-7/16
5-1/4
4-1/8
3-1/4
2-1/4
1-3/4
FLOOR
MANUAL ISOLATION
VALVE (TYP)
FLOW SENSOR
2-1/2"
DUPLEX WATER
SOFTENER
2" 2"
1"
TERMINATE BACKWASH
INDIRECT CONNECTION TO FLOOR DRAIN
BRINE TANK
CONTROLLER
(TYP)
2"
2"
2
DUPLEX WATER SOFTENER DETAIL
SCALE: NOT TO SCALE
TO HOT WATER HEATERS
WS-1
WS-2
WATER SOFTENER PIPING IS
DIAGRAMATIC, INSTALL ALL
PIPING IN STRICT ACCORDANCE
WITH MANUFACTURERS
RECOMENDATIONS.
PRESSURE
GAUGE (TYP)
4 21/2 1/2
SH-2
SHOWER BASE BY OTHERS WITH MOEN 8346 SINGLE-HANDLE PRESSURE BALANCING SHOWE5R VALVE WITH HAND-HELD SHOWER
SYSTEM SEAT AND GRAB BAR
NOTE:
PROVIDE ALL FIXTURES WITH THE APPROPRIATE SUPPLIES, STOPS, NIPPLES, PLATES AND ESCUTCHEONS. ALL
EXPOSED PIPING TO BE CHROME POLISHED FINISH MATERIAL.
SEE PLANS
WATER HEATER SYSTEM PIPING DIAGRAM
SCALE: NONE
1
WH-2WH-1
CW CW CW CW
WH-3
GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS
CW CW CW CW CW CW CW CW CW CW
CW CW CW CW CW CW CW CW CW CW CW CW CW CW CW CW CW CW CW CW CW CW CW CW CW CW CW CW CW CW CW CW CW CW CW CW CW
HW
RH
WR
HW
R
CW
HW
SH
WS
HW
SH
WS
FLOOR DRAIN
SEE FLOOR PLANS
FOR LOCATION
PRESSURE GAUGE
(TYP)
CW
CW
CW
CHECK VALVE
(TYP)
2" THERMOSTATIC
MIXING VALVE
TMV
BALANCE VALVE
(TYP)
27"
1-1/4"
HEAT TRAP
4" PVC COMBUSTION AIR
& 4" PVC FLUE PER
MANUFACTURER
(TYP) INSTALLED BY P.C.
ASME T&P
RELIEF VALVE
(TYP)
TERMINATE RELIEF
OVER FLOOR DRAIN
HWS HWS HWS HWS HWS HWS HWS HWS HWS
HWR HWR HWR
HW
RH
WR
HW
RH
WR
HW
R
HWR HWR HWR
FLOOR
CW CW CW CW CW CW CW CW CW CW CW CW
120° HW
160° HW
CW
CW
CW
CW
2 1/2"
1 1/4"
WATER HEATER PIPING IS
DIAGRAMATIC, INSTALL ALL
PIPING IN STRICT ACCORDANCE
WITH MANUFACTURERS
RECOMENDATIONS.
RP
RP
FROM CITY WATER
SEE FLOOR PLANS
FOR CONTINUATION
GA
SG
AS
GA
SG
AS
GA
SG
AS
3/4"
CW
WH-4
GA
SG
AS
GA
SG
AS
HWR HWR HWR
HW
RH
WR
HWR
HWR
D D DD
FROM CITY GAS
EXPANSION TANK
REG REG REG REG
3"CW
2-1/2"CW
-- -
FD2
FLOOR DRAIN: SMITH 2010-A05-NB SERIES CAST IRON BODY WITH FLASHING COLLAR, CONNECTION AND ADJUSTABLE 5" SQUARE
CHROME PLATED BRASS
SEE PLANS
160°HW 160°HW 160°HW 160°HW160°HW160°HW160°HW160°HW
160°HW 160°HW
160°HW
NOTE:
ALL FIXTURES SELECTED TO BE PER HAMPTON BY HILTON BRAND STANDARDS MANUAL.
2506.03 Vending Area
2504.01 Food Prep
LAWLER THERMOSTATIC MIXING VALVE MODEL 66
TMV
1-1/4"G
AGA SHUT OFF VALVE, NIPPLE
AND CAP W/ MAXTROL TYPE
VENTLESS REGULATOR(TYP)
2-1/2"CW
1-1/2"1-1/2"
HUB DRAIN
SEE FLOOR PLANS
FOR LOCATION
DIM
EN
SIO
NS
O
I
H
O
F
E
T
A
T
S
PR
O
F
E
S
S
I
O
N
A
L
E
N
G
I
N
E
E
R
TS
G
I
R
E
E
GOODERUM
O
DAVID R.
74178
R
E
D
SCALE: NOT TO SCALE
HOT & COLD WATER - TYPICAL ISOMETRIC
1
HW
RH
WR
HW
RH
WR
HW
RH
WR
HW
RH
WR
HW
RH
WR
HW
RH
WR
HW
RH
WR
HW
RH
WR
HW
RH
WR
HW
RH
WR
HW
RH
WR
HW
SH
WS
HW
SH
WS
HW
SH
WS
HW
SH
WS
HW
SH
WS
HW
SH
WS
HW
SH
WS
HW
SH
WS
HW
SH
WS
HW
SH
WS
HW
SH
WS
CW
SC
WS
CW
SC
WS
CW
SC
WS
CW
SC
WS
CW
SC
WS
CW
SC
WS
CW
SC
WS
CW
SC
WS
CW
SC
WS
CW
SC
WS
CW
SC
WS
3/4"HWR
1"HW
1"CW
3/4"HWR
3/4"HW
3/4"CW
2ND FLOOR
3RD FLOOR
C
W
S
H
W
S
H
W
S
H
W
S
CW
SC
WS
HW
SH
WS
HW
SH
WS
H
W
S
H
W
S
H
W
S
SH-1
L-1
HW
SH
WS
HW
S
CW
S
CW
SC
WS
CW
SC
WS
CW
S
3/4"
3/4"
1/2"
1/2"
WC-1
C
W
S
H
W
S
H
W
S
H
W
S
CW
SC
WS
CW
S
HW
SH
WS
HW
SH
WS
H
W
S
H
W
S
H
W
S
SH-1
L-1
HW
SH
WS
HW
SH
WS
CW
SC
WS
C
W
S
CW
SC
WS
CW
SC
WS
CW
S
3/4"
3/4"
1/2"
1/2"
WC-1
2ND FLOOR
3RD FLOOR
ATTIC
SCALE: NOT TO SCALE
WASTE & VENT - TYPICAL ISOMETRIC
2
SA
NS
AN
SA
NS
AN
SA
NS
AN
SA
NS
AN
SA
NS
AN
SA
NS
AN
SA
NS
AN
SA
NS
AN
SA
NS
AN
SA
NS
AN
SA
NS
AN
SA
NS
AN
SA
NS
AN
SA
NS
AN
SA
NS
AN
SA
NS
AN
SA
N
SH-1
L-1
WC-1
3"VENT
2" WASTE
2"
3"
3"VTR
3"WASTE
C
W
S
H
W
S
H
W
S
H
W
S
CW
SC
WS
CW
S
HW
SH
WS
HW
SH
WS
H
W
S
H
W
S
H
W
S
SH-1
L-1
HW
SH
WS
HW
S
CW
S
CW
SC
WS
CW
S
3/4"
3/4"
1/2"
1/2"
WC-1
H
W
R
H
W
S
C
W
S
1ST FLOOR
1-1/4"CW
3/4"HWR
1-1/4"HW
S
A
N
S
A
N
SA
NS
AN
SA
NS
AN
SA
NS
AN
SA
NS
AN
SA
NS
AN
SA
NS
AN
SA
NS
AN
SA
NS
AN
SA
NS
AN
SA
NS
AN
SA
NS
AN
SA
NS
AN
SA
NS
AN
SA
NS
AN
SA
N
S
A
N
S
A
N
S
A
N
S
A
N
L-1
SH-1
WC-1
2"
3"
S
A
N
S
A
N
1ST FLOOR
3"WASTE
3"VENT
1-1/2"
1-1/2"
2" WASTE
L-1
1-1/2"
2" WASTE
SH-1
WC-1
2"
3"
S
A
N
S
A
N
3"VENT
G
J
H
E
F
K
L
M
2 18 19
3 45
6 7 8
9 10 11 12
13 14 15 16 17
3.9
9.9 11.1
16.11
C
A
10.4 12.6
B
D
G
J
H
E
F
K
L
M
C
B
D
KING
101
KING
103
MANAGER
029
COMPUTER/
PBX
027
WORK
AREA
026
FRONT
DESK
021
VESTIBULE
001
MAIN
LOBBY
006
ELEV.
LOBBY
191
MENS
RR
018
WMNS
RR
019
MTG.
STOR.
015
MEETING
ROOM
013
BREAKFAST
AREA
006
PANTRY
009
FOOD
PREP.
012
FOOD
PREP
STOR.
011
MECH.
010
KING
129
KING
131
ACCESSIBLE
KING
127
KING
128
KING
130
VEST.
003
VEST.
004
DOUBLE QUEEN
125
MECH.
MECH.
EMP.
RR
040
LINEN
STORAGE/
FOLDING
035
EMP.
BREAK
ROOM
038
FITNESS CENTER
020
POOL
050
MECH.
031
POOL
RR
052
GUEST
LAUND.
025
ELEV.
1
LAUNDRY
034
MAINTENANCE/
MECHANICAL/
ELECTRICAL
017
DOUBLE QUEEN
105
DOUBLE QUEEN
107
STORAGE
005
POOL PATIO
--
POOL
EQUIPMENT
051
TREATS
002
MECH.
016
ELEV.
2
VENDING
193
A
G.2 G.2
VTAC
ELECTRICAL
043
STAIR 2
181
STAIR 1
180
CORRIDOR
198
CORRIDOR
197
CORR.
199
DRYERS
036
1 2
SAN SAN SAN SAN SAN SAN SAN SAN SAN SAN SAN SAN SAN SAN SAN SAN SAN SAN SAN SAN SAN SAN SAN SAN SAN SAN SAN SAN SAN SAN SAN SAN SAN SAN SAN SAN SAN SAN SAN SAN SAN SAN SAN SAN SAN SAN SAN SAN SAN SAN SAN SAN SAN SAN SAN
SA
NS
AN
SA
NS
AN
SA
NS
AN
SA
NS
AN
SA
NS
AN
WC2
LV2
WC2
LV2
WC2 LV3WC1
LV1
SH1
LV1
SH1 WC1 WC1
LV1
TB1
LV1
TB1 WC1
SK2
EW
MS
SK1
LV1
TB1
WC1
LV1
SH2
WC1H
LV1
SH1
WC1
SH1
WC1
LV1
SH1
SH1
WC1 WC1
LV1 LV1
LV2
SK3
WC2 LV3
SA
N
SA
N
SA
N
SA
N
SA
N
SA
N
SAN SAN SAN
SA
N
SAN SAN
SAN SAN
SP
SAN
SAN
SA
NS
AN
SA
NS
AN
SA
N
GL
GL
SA
NS
AN
GI
SAN SAN SAN
FD
6"W
CO
CO
CO
SAN SAN
SAN SANSAN SANSAN SAN
CO
SA
N
HD
SA
N
SA
N
IE=-43.25"
6"W
6"W
6"W
6"W
6"W
6"W
6"W 6"W6"W
6"W6"W
6"W 6"W
2"W
3"W
3"W
3"W
3"W
3"W
3"W3"W3"W
4"W
2"W
3"W
2"W
HD
HD
HD
SA
N
SAN
FS
CO
HD
WB
2"W
2"W
3"W
3"W
2"W
2"W
2"W
2"W
2"W
2"W
2"W
3"W
2"W
2"W
2"W
SA
N
SA
N
SA
N
SA
N
2"W2"W
2"W2"W
3"W 3"W 3"W 3"W 3"W 3"W 3"W 3"W 3"W
3"W
3"W
3"W 3"W 3"W 3"W 3"W 3"W 3"W 3"W 3"W 3"W 3"W 3"W 3"W
4"W
4"W
4"W
4"W
4"W3"W
3"W
3"W 3"W
2"W
2"W
3"W
3"W
3"W
3"W
3"W
3"W 3"W
3"W3"W
3"W3"W
3"W
3"W
3"W
2"W
2"W
SAN SAN
TD
VV
V
V V V
V
V
V V V V V V V
VV
VV
V
V
SD
SD
V
WB
V V
V
V
V
V
V
V
V
V
V V
V
V
V
V
V
V
V
V
V
VV
V
V
V
V
VV
VV
V
FS
VV
VV
3"W
FD
SP
FD
SA
N
6"W
CAST IRON PIPE
AND FITTINGS REQD
FD2
FD2
FD2
FD2
2"W
FD2
SAN SAN
2"WFD FD
SA
NS
AN
S
A
N
S
A
N
SAN SAN
3"W
HD
HD
FD
FD
HD
SAN SAN SAN SAN SAN
2"W
3"W
3"W
3"W
3"W
FD2
NOTE: ALL POOL DESIGN INCLUDING DECK DRAINAGE TO BE
BY POOL CONTRACTOR AND/OR MFG SUPPLIER
FD2
KEY NOTES:
1. REFERENCE SHEET P-001 FOR LEGENDS,
ABBREVIATIONS, SPECIFICATIONS AND NOTES.
GENERAL NOTES:
1
DIM
EN
SIO
NS
O
I
H
O
F
E
T
A
T
S
PR
O
F
E
S
S
I
O
N
A
L
E
N
G
I
N
E
E
R
TS
G
I
R
E
E
GOODERUM
O
DAVID R.
74178
R
E
D
1
SCALE: 1/8" = 1'-0"
FIRST FLOOR PLUMBING WASTE PLAN
6" INCOMING SEWER SERVICE. SEE CIVIL PLANS
FOR CONTINUATION.
GREASE INTERCEPTOR. THERMOCO TRAPZILLA IS
POINT SOURCE AUTOMATIC GREASE REMOVAL
SYSTEM IN-GROUND MODEL TZ-160-ECA COMPLETE
W/ ACCESSORIES.
6" SUMP/ HUB DRAIN FOR POOL BACKWASH.
3" SOIL STACK AND 3" VENT STACK UP TO FLOORS
ABOVE. SEE ISOMETRIC DRAWINGS FOR
CONTINUATION.
2" SOIL STACK UP TO FLOORS ABOVE. SEE
ISOMETRIC DRAWINGS FOR CONTINUATION.
PROVIDE AND INSTALL NEW SUMP AND PUMP FOR
ELEVATOR HOISTWAY. PUMP TO BE LIKE:
LIBERTY MODEL 290,
3
4
HP, 115V 50 GPM @ 28'
HEAD WITH SXL24-3 NEMA 4X SIMPLEX
CONTROL PANEL, BCV150 CHECK VALVE,
XT24BX36 24"X36" FIBERGLASS SUMP AND
XC24P2395 PERFORATED STEEL COVER
PUMP UP TO SANITARY HUB DRAIN 2" DISCHARGE
LINE AND CONNECT WITH AIR GAP FITTING INTO
THE 3" HUB DRAIN.
PRIMARY ROOF DRAINS RISER DOWN FROM ATTIC
ABOVE AND ROUTED TO STORM WATER RISER AS
SHOWN ON P-101. SEE CIVIL PLANS FOR
CONTINUATION.
3" VENT STACK UP TO ATTIC ABOVE.
P.C. TO INSULATE ALL ICE MACHINE DRAIN TRAPS.
2
3
4
5
6
7
8
9
1
2
3
4
4
4
4
4
44
4
4
4
4
4
4
4
44
44
4
4
4
4
4
4
4
4
4
45
5
55
5
5
5
5
5
5
5
5
5
55
5
5 5
5
5
5
5
55
5
55
5
7
8
8
8
8
6
5
9
10
10
G
J
H
E
F
K
L
M
2 18 19
3 45
6 7 8
9 10 11 12
13 14 15 16 17
3.9
9.9 11.1
16.11
C
A
10.4 12.6
B
D
G
J
H
E
F
K
L
M
C
B
D
KING
101
KING
103
MANAGER
029
COMPUTER/
PBX
027
WORK
AREA
026
FRONT
DESK
021
VESTIBULE
001
MAIN
LOBBY
006
ELEV.
LOBBY
191
MENS
RR
018
WMNS
RR
019
MTG.
STOR.
015
MEETING
ROOM
013
BREAKFAST
AREA
006
PANTRY
009
FOOD
PREP.
012
FOOD
PREP
STOR.
011
MECH.
010
KING
129
KING
131
ACCESSIBLE
KING
127
KING
128
KING
130
VEST.
003
VEST.
004
DOUBLE QUEEN
125
MECH.
MECH.
EMP.
RR
040
LINEN
STORAGE/
FOLDING
035
EMP.
BREAK
ROOM
038
FITNESS CENTER
020
POOL
050
MECH.
031
POOL
RR
052
GUEST
LAUND.
025
ELEV.
1
LAUNDRY
034
MAINTENANCE/
MECHANICAL/
ELECTRICAL
017
DOUBLE QUEEN
105
DOUBLE QUEEN
107
STORAGE
005
POOL PATIO
--
POOL
EQUIPMENT
051
TREATS
002
MECH.
016
ELEV.
2
VENDING
193
A
G.2 G.2
VTAC
ELECTRICAL
043
STAIR 2
181
STAIR 1
180
CORRIDOR
198
CORRIDOR
197
CORR.
199
DRYERS
036
1 2
FP
CW
CW
CW
CW
CW
CW
CW
CW
CW
WC2
LV2
GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS
HWR HWR HWR HWR HWR HWR HWR HWR HWR HWR HWR HWR HWR HWR HWR HWR HWR HWR HWR HWR HWR HWR HWR HWR HWR HWR HWR HWR HWR HWR HWR HWR HWR HWR HWR HWR HWR
3/4"HWR,
2-1/2"HW &
2-1/2"CW
1"HWR,
2-1/2"HW &
2-1/2"CW
WC2
LV2
WC2 LV3WC1
LV1
SH1
LV1
SH1 WC1 WC1
LV1
TB1
LV1
TB1 WC1
SK2
EW
MS
SK1
LV1
TB1
WC1
LV1
SH2
WC1H
LV1
SH1
WC1
SH1
WC1
LV1
SH1
SH1
WC1 WC1
LV1 LV1
LV2
SK3
WC2 LV3
RPZ
RP
RP
GA
SG
AS
GA
S
TMV
1-1/4"C
W
Gas Service
1.7 mbh @ 2 psi
M
HW
SH
WS
HW
RH
WR
HWS
HW
SH
WS
HW
SH
WS
HW
S
CW
CW
CW
CW
CW
CW
CW CW
HWS HWS
HW
SH
WS
HW
SH
WS
HW
SH
WS
HW
S
CW
CW
CW
CW
CW
CW
CW
HWS
CW CW
HW
SH
WS
CW
CW
CW
GL
GL
GI
HW
R
GAS GAS
GA
S
3"W
2"W
SD
SD
8"STM 6"STM
3"STM
4"STM
8"STM8"STM
3/4"HWR,
1-1/2"HW &
1-1/2"CW
1"HWR,
2"HW &
2"CW
4"STM 5"STM 5"STM 4"STM 4"STM 5"STM 4"STM5"STM
1"HWR,
2"HW &
2"CW
1"HWR,
2-1/2"HW &
2-1/2"CW
1"HWR,
2-1/2"HW &
2-1/2"CW
1"HWR,
2-1/2"HW &
2-1/2"CW
1"HWR,
2-1/2"HW &
2-1/2"CW
3/4"HWR,
2"HW &
2"CW
3/4"HWR,
1-1/4"HW &
1-1/4"CW
(typ.)
1"HWR,
1-1/4"HW &
1-1/4"CW
(typ.)
3/4"HWR,
1-1/4"HW &
1-1/4"CW
(typ.)
GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS
GA
SG
AS
GA
S
3/4"G
3/4"G
1-1/2"G
1-1/4"G
1-1/4"G
1"G
1-1/4"G1-1/4"G
1-1/4"G
1-1/4"G
1"HWR,
2-1/2"HW &
3"CW
M
3"CW 6"FP
3/4"CW
3/4"HW
1"CW
3/4"HW
1-1/4"160°HW
1-1/4"160°HW
1/2"CW
1/2"HW
HW
SH
WS
HW
SH
WS
HW
SH
WS
HW
S
CW
CW
CW
CW
CW
CW
CW
1"CW
1/2"HW
CW
WB
1"CW
1/2"HW
HW
SH
WS
HW
SH
WS
HW
SH
WS
CW
CW
CW
CW
CW
CW
3/4"CW
3/4"HW
CW
CW
CW
1/2"CW
FS
HB
HB
CW CW
3/4"CW
3/4"CW
GA
SG
AS
GA
SG
AS
GA
SG
AS
GAS
1"G
3/4"G
3"W
HB
HB
CAST IRON PIPE
AND FITTINGS REQD
160°HW
CW
CW
CW
CW
HB*
3" INCOMING DOMESTIC WATER SERVICE. SEE CIVIL
PLANS FOR CONTINUATION.
6" FIREPROTECTION WATER SERVICE. SEE CIVIL
PLANS FOR CONTINUATION.
2 PSI GAS SERVICE. P.C. TO SLEEVE AND SEAL
EXTERIOR WALL PENETRATION. COORDINATE WITH
LOCAL GAS COMPANY NEW GAS SERVICE TO
BUILDING.
STORM WATER RISER DROP FROM OVERHEAD
PIPING SYSTEM TO SITE STORM WATER
CONNECTIONS. SEE CIVIL PLANS FOR
CONTINUATION.
STORM WATER RISER DROP FROM CANOPY ABOVE.
RISERS TO BE LOCATED INSIDE COLUMN
ENLOSURE AND ARCHITECTURAL CHASE.
1" CW, 1" HW AND 3/4" HWR RISER LOCATION.
3" STORM RISER FROM ABOVE. TURN OUT PIPING
TIGHT TO STRUCTURE.
1-1/2" CW POOL WATER SUPPLY AND 3/4" GAS
SUPPLY TO POOL EQUIPMENT ROOM WITH 2 PSIG
TO 6" W.C. REGULATOR. P.C. TO PROVIDE AND
COORDINATE POOL EQUIPMENT CONNECTIONS W/
POOL CONTRACTOR. P.C. TO ENSURE POOL
CONTRACTOR IS PROVIDING BACK FLOW DEVICE. IF
NOT P.C. SHALL PROVIDE DEVICE AS REQUIRED.
PROVIDE 1/2" CW FEED FOR FUTURE WATER
COOLER IN FITNESS. ROUGH IN CW DOWN TO 1/2"
SHUT OFF VALVE. VERIFY WITH OWNER LOCATION
AND HEIGHT OF SUPPLY VALVE BOX.
3/4" ICE MACHINE COLD WATER SUPPLY DOWN TO
1ST FLOOR AND UP TO 2ND AND 3RD FLOOR
MACHINES. PROVIDE AND INSTALL 1/2" SUPPLY
VALVE IN BOX AT 12" AFF. P.C. TO COORDINATE
WITH OWNER ANY FILTRATION NEEDS FOR
MACHINES.
P.C. TO PROVIDE INTERIOR HOSE BIBB FOR POOL
EQUIPMENT ROOM WASH WATER. SET VALVE AT 42"
AFF. BOILER DRAIN TYPE W/ VACUUM BREAKER
STYLE HOSE CONNECTION.
PROVIDE 1/2" CW FEED FOR FUTURE COFFEE/JUICE
BAR. PROVIDE AND INSTALL 1/2" SUPPLY VALVE IN
BOX AT 12" AFF. P.C. TO COORDINATE WITH OWNER
ANY FILTRATION NEEDS.
KEY NOTES:
1. REFERENCE SHEET P-001 FOR LEGENDS,
ABBREVIATIONS, SPECIFICATIONS AND NOTES.
GENERAL NOTES:
1
DIM
EN
SIO
NS
O
I
H
O
F
E
T
A
T
S
PR
O
F
E
S
S
I
O
N
A
L
E
N
G
I
N
E
E
R
TS
G
I
R
E
E
GOODERUM
O
DAVID R.
74178
R
E
D
1
SCALE: 1/8" = 1'-0"
FIRST FLOOR PLUMBING WATER PLAN
2
3
4
5
6
1
2
3
4
4
5
5
6
6
6
6
6
6
66
6
6
6
6
66 6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
7
8
8
9
9
10
10
11
11
12
12
KING SOFA
200
KING SOFA
202
DOUBLE
QUEEN
204
DOUBLE
QUEEN
206
KING
201
KING
203
DOUBLE
QUEEN
205
DOUBLE
QUEEN
207
DOUBLE
QUEEN
209
DOUBLE
QUEEN
211
DOUBLE
QUEEN
213
DOUBLE
QUEEN
215
DOUBLE
QUEEN
219
DOUBLE
QUEEN
221
DOUBLE
QUEEN
223
DOUBLE
QUEEN
225
KING
231
KING
229
KING
230
KING
228
ACCESSIBLE
KING
226
ACCESSIBLE
KING
227
ACCESSIBLE
DOUBLE
QUEEN
216
STORAGE
294
ELEV.
1
ELECTRICAL/
HOUSE
KEEPING
295
ELEV.
2
G
J
H
E
F
K
L
M
2 18 19
3 45
6 7 8
9 10 11 12
13 14 15 16 17
3.9
9.9 11.1
16.11
C
D
G
J
H
E
F
K
L
M
C
D
STORAGE
292
G.2 G.2
DOUBLE
QUEEN
208
DOUBLE
QUEEN
210
DOUBLE
QUEEN
212
DOUBLE
QUEEN
214
DOUBLE
QUEEN
218
DOUBLE
QUEEN
220
DOUBLE
QUEEN
222
DOUBLE
QUEEN
224
D.5D.5
VENDING
293
ELEVATOR
LOBBY
297
CORRIDOR
291
CORRIDOR
290
STAIR 1
280
STAIR 2
281
WC1
LV1
TB1
LV1
TB1
LV1
TB1 WC1WC1
LV1
SH1 WC1
LV1
SH1
WC1
LV1
TB1
LV1
TB1
LV1
TB1
LV1
TB1
LV1
TB1
LV1
TB1
LV1
SH2
WC1H
LV1
SH2
WC1H
LV1
SH1
LV1
SH1
LV1
TB1
LV1
TB1
LV1
TB1
LV1
TB1
WC1
WC1 WC1 WC1
LV1
TB1WC1 WC1
LV1
TB1
WC1H
TB2
LV1
SH1
WC1
WC1 WC1WC1
WC1WC1 WC1
WC1
LV1 LV1
WC1
SH1
SH1SH1WC1
LV1
TB1 WC1
LV1
TB1 WC1
LV1
TB1 WC1
LV1
TB1
WC1
LV1
LV1
WC1
WC1
WC1
SA
N
SA
N
SA
N
SA
N
SA
N
SA
N
SA
N
SA
N
SA
N
SA
N
SA
N
SA
N
SA
N
SA
N
SA
N
SA
N
SA
N
SA
N
SA
N
SA
N
SA
N
SA
N
SA
N
SA
N
V V
V
V
V
V
V
V
V
V
V V
V
V
V
V
V
V
V
V
V
VV
V
V
V
V
2"W 2"W
2"W
2"W2"W
2"W2"W
2"W
2"W
2"W
2"W
2"W
2"W 2"W 2"W
2"W
2"W
2"W2"W
2"W2"W
2"W2"W
2"W 2"W
2"W
2"W
2"W
2"W
2"W
2"W
2"W
FS FD2
FD2
FD2
FD2
KEY NOTES:
1. REFERENCE SHEET P-001 FOR LEGENDS,
ABBREVIATIONS, SPECIFICATIONS AND NOTES.
GENERAL NOTES:
DIM
EN
SIO
NS
O
I
H
O
F
E
T
A
T
S
PR
O
F
E
S
S
I
O
N
A
L
E
N
G
I
N
E
E
R
TS
G
I
R
E
E
GOODERUM
O
DAVID R.
74178
R
E
D
1
SCALE: 1/8" = 1'-0"
SECOND FLOOR PLUMBING PLAN
3" WASTE STACK AND 3" VENT STACK
2" WASTE STACK
3" STORM RISER
1" GAS RISER
1" CW, 1" HW AND 3/4" HWR RISER
3" VENT STACK FROM 1ST FLOOR
P.C. TO INSULATE ALL ICE MACHINE DRAIN TRAPS.
3/4" CW SUPPLY UP TO ICE MACHINE. P.C. TO
PROVIDE 1/2" WATER SUPPLY VALVE AND BOX AT
12" AFF. COORDINATE WITH OWNER ANY
FILTRATION NEEDS.
1
2
3
4
5
1111111111111111
2222222222222222
3
3
3
33
3
3
3
4
5
5 5
5
5
5
5
5
5
5
5
5
5
5
5
5 5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
6
6
7
7
8
8
KING SOFA
300
KING SOFA
302
DOUBLE
QUEEN
304
DOUBLE
QUEEN
306
DOUBLE
QUEEN
308
DOUBLE
QUEEN
310
DOUBLE
QUEEN
312
DOUBLE
QUEEN
314
DOUBLE
QUEEN
320
DOUBLE
QUEEN
322
DOUBLE
QUEEN
324
KING
301
KING
303
DOUBLE
QUEEN
305
DOUBLE
QUEEN
307
DOUBLE
QUEEN
309
DOUBLE
QUEEN
311
DOUBLE
QUEEN
313
DOUBLE
QUEEN
315
DOUBLE
QUEEN
319
DOUBLE
QUEEN
321
DOUBLE
QUEEN
323
DOUBLE
QUEEN
325
KING
331
KING
329
KING
330
KING
328
ACCESSIBLE
KING
SOFA
316
ACCESSIBLE
KING
327
STORAGE
394
ELEV.
1
ELEV.
2
ELECTRICAL/
HOUSE
KEEPING
395
G
J
H
E
F
K
L
M
2 18 19
3 45
6 7 8
9 10 11 12
13 14 15 16 17
3.9
9.9 11.1
16.11
C
D
G
J
H
E
F
K
L
M
C
D
G.2 G.2
STORAGE
392
DOUBLE
QUEEN
318
ACCESSIBLE
KING
326
VENDING
393
ELEVATOR
LOBBY
397
CORRIDOR
391
CORRIDOR
390
STAIR 2
381
STAIR 1
380
WC1
LV1
TB1
LV1
TB1
LV1
TB1 WC1WC1
LV1
SH1 WC1
LV1
SH1
WC1
LV1
TB1
LV1
SH1
LV1
SH1
LV1
TB1
LV1
TB1
LV1
TB1
LV1
TB1
WC1
WC1 WC1 WC1 WC1
WC1
WC1
WC1
WC1
LV1
TB1
LV1
TB1
LV1
TB1
LV1
TB1
LV1
TB1
LV1
SH2
WC1H
LV1
WC1H
LV1
TB1 WC1
LV1
TB1
WC1H
TB2
LV1
SH1
WC1WC1
WC1WC1 WC1
WC1
LV1 LV1
WC1
SH1
SH1SH1WC1
LV1
TB1 WC1
LV1
TB1
WC1
LV1
LV1
WC1
LV1
TB1
LV1
TB1WC1 WC1
LV1
TB1
SA
N
SA
N
SA
N
SA
N
SA
N
SA
N
SA
N
SA
N
SA
N
SA
N
SA
N
SA
N
SA
N
SA
N
SA
N
SA
N
SA
N
SA
N
SA
N
SA
N
SA
N
SA
N
SA
N
SA
N
V V
V
V
V
V
V
V
V
V
V V
V
V
V
V
V
V
V
V
V
VV
V
V
V
V
2"W2"W
2"W
2"W2"W
2"W
2"W
2"W
2"W
2"W 2"W2"W
2"W 2"W 2"W
2"W
2"W
2"W2"W
2"W
2"W
2"W2"W
2"W2"W
FD2
2"W
2"W
2"W
2"W
2"W
2"W
SH2
FS FD2
FD2
2"W
FD2
3" WASTE STACK AND 3" VENT STACK
2" WASTE STACK
3" STORM RISER
1" GAS RISER
3/4" CW, 3/4" HW AND 3/4" HWR RISER
3" VENT STACK FROM 1ST FLOOR.
P.C. TO INSULATE ALL ICE MACHINE DRAIN TRAPS.
KEY NOTES:
1. REFERENCE SHEET P-001 FOR LEGENDS,
ABBREVIATIONS, SPECIFICATIONS AND NOTES.
GENERAL NOTES:
1
DIM
EN
SIO
NS
O
I
H
O
F
E
T
A
T
S
PR
O
F
E
S
S
I
O
N
A
L
E
N
G
I
N
E
E
R
TS
G
I
R
E
E
GOODERUM
O
DAVID R.
74178
R
E
D
1
SCALE: 1/8" = 1'-0"
THIRD FLOOR PLUMBING PLAN
2
3
4
5
1111111111111111
2222222222222222
3
3
3
33
3
3
3
4
5
5 5
5
5
5
5
5
5
5
5
5
5
5
5
5 5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
6
6
7
7
RS
RS RS
RS
RS RS
RS
RS
RSRSRS
RS
RD RD RD RD RD RD RD RD
3"Ø3"Ø3"Ø3"Ø3"Ø3"Ø3"Ø3"Ø
RD
3"Ø
RD
3"Ø
RD
3"Ø
SD
SD
SD
SD
SD
SD
SD SD SD SD
1213 SF
3"Ø
4"Ø
SD SD
3"Ø
GA
SG
AS
GA
SG
AS
GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS
1"Ø
GAS
1"Ø
GA
S
ROOF DRAIN LOCATION. SEE DETAIL ON P-002 FOR
DETAIL.
4" CANOPY DRAIN DOWN IN COLUMN CHASE
ENCLOSURE BELOW.
3" CANOPY DRAIN DOWN IN CHASE BELOW.
1" GAS DOWN IN STORAGE ROOM BELOW.
4" VENT THRU ROOF. SEE DETAIL ON P-002.
GAS FIRED MAKE UP AIR UNIT. SEE CONNECTION
DETAIL ON P-002.
KEY NOTES:
1. REFERENCE SHEET P-001 FOR LEGENDS,
ABBREVIATIONS, SPECIFICATIONS AND NOTES.
GENERAL NOTES:
1
DIM
EN
SIO
NS
O
I
H
O
F
E
T
A
T
S
PR
O
F
E
S
S
I
O
N
A
L
E
N
G
I
N
E
E
R
TS
G
I
R
E
E
GOODERUM
O
DAVID R.
74178
R
E
D
1
SCALE: 1/8" = 1'-0"
ROOF PLUMBING PLAN
2
3
4
1
11
1
1
1
1
1
2
3
4
5
5
5
5
5
5
5
5
5
5
55
5
5
5
5
5
5
6
6