+ All Categories
Home > Documents > Direct LC/MS/MS Analysis of Glyphosate, AMPA and other Polar · 2017-08-08 · Direct LC/MS/MS...

Direct LC/MS/MS Analysis of Glyphosate, AMPA and other Polar · 2017-08-08 · Direct LC/MS/MS...

Date post: 18-Jun-2020
Category:
Upload: others
View: 1 times
Download: 0 times
Share this document with a friend
18
Direct LC/MS/MS Analysis of Glyphosate, AMPA and other Polar Pesticides Jerry Zweigenbaum Agilent User’s meeting July 27, 2017 Agilent User's Meeting-NACRW What is the best way to do this analysis? 1
Transcript
Page 1: Direct LC/MS/MS Analysis of Glyphosate, AMPA and other Polar · 2017-08-08 · Direct LC/MS/MS Analysis of Glyphosate, AMPA and other Polar Pesticides Jerry Zweigenbaum Agilent User’s

Direct LC/MS/MS Analysis of Glyphosate, AMPA and other Polar Pesticides

Jerry ZweigenbaumAgilent User’s meeting

July 27, 2017 Agilent User's Meeting-NACRW

What is the best way to do this analysis?

1

Page 2: Direct LC/MS/MS Analysis of Glyphosate, AMPA and other Polar · 2017-08-08 · Direct LC/MS/MS Analysis of Glyphosate, AMPA and other Polar Pesticides Jerry Zweigenbaum Agilent User’s

July 27, 2017 Agilent User's Meeting-NACRW2

Target AnalytesHerbicides

Compounds Compounds

Glyphosate Ethephon

AMPA HEPA

Glufosinate MPPA

N-acetyl Glufosinate Fosetyl

Maleic hydrazide

Page 3: Direct LC/MS/MS Analysis of Glyphosate, AMPA and other Polar · 2017-08-08 · Direct LC/MS/MS Analysis of Glyphosate, AMPA and other Polar Pesticides Jerry Zweigenbaum Agilent User’s

• Chelate with metal ions

– New SS

– Old SS

• Erratic behavior

• Some systems ok

• Some systems show loss of analyte

– Use of EDTA

– Passivation with phosphoric acid

July 27, 2017 Agilent User's Meeting-NACRW3

Strong Acid/Weak Acid/Zwitterion?

Issues with Analysis of Glyphosate

P

O

OH

OH

O

OHNH

NH2

POH

OHO

P

O

OHO

OH

NH2

CH3

Page 4: Direct LC/MS/MS Analysis of Glyphosate, AMPA and other Polar · 2017-08-08 · Direct LC/MS/MS Analysis of Glyphosate, AMPA and other Polar Pesticides Jerry Zweigenbaum Agilent User’s

1. HILIC silica based

2. iHILIC polymer based

3. Reversed-phase chromatography

4. Anion exchange chromatography with suppresser column

5. Anion exchange without suppressor column

6. Cation exchange chromatography

7. Mixed mode chromatography

8. Ion pair chromatography (with reversed-phase column)

9. Capillary Electrophoresis (not chromatography but we will count it)

July 27, 2017 Agilent User's Meeting-NACRW4

At this meeting alone:

Chromatographic Methods all LC/MS/MS

Page 5: Direct LC/MS/MS Analysis of Glyphosate, AMPA and other Polar · 2017-08-08 · Direct LC/MS/MS Analysis of Glyphosate, AMPA and other Polar Pesticides Jerry Zweigenbaum Agilent User’s

??Thoughts on the chromatography (or electrophoresis)??

July 27, 2017 Agilent User's Meeting-NACRW5

Page 6: Direct LC/MS/MS Analysis of Glyphosate, AMPA and other Polar · 2017-08-08 · Direct LC/MS/MS Analysis of Glyphosate, AMPA and other Polar Pesticides Jerry Zweigenbaum Agilent User’s

Parameter

Liquid Chromatograph 1260 Infinity Quaternary Bio-inert LC with 100 µL injection loop

Analytical Column Metrohm Asupp 4, 4.0x200 mm

Flowrate 0.7 mL/min

Temperature 45 ºC

Mobile Phase A: WaterB: 50 mM Ammonium acetateC: 50 mM Ammonium Hydroxide

Gradient

Runtime 20.0 min

July 27, 2017 Agilent User's Meeting-NACRW6

Chromatographic Conditions

Time (min)

A % B % C %

0.0 25 45 30

3.0 25 45 30

7.0 0 90 10

16.5 0 90 10

17.0 25 45 30

Page 7: Direct LC/MS/MS Analysis of Glyphosate, AMPA and other Polar · 2017-08-08 · Direct LC/MS/MS Analysis of Glyphosate, AMPA and other Polar Pesticides Jerry Zweigenbaum Agilent User’s

July 27, 2017 Agilent User's Meeting-NACRW7

Separation on Metrohm Column

Page 8: Direct LC/MS/MS Analysis of Glyphosate, AMPA and other Polar · 2017-08-08 · Direct LC/MS/MS Analysis of Glyphosate, AMPA and other Polar Pesticides Jerry Zweigenbaum Agilent User’s

July 27, 2017 Agilent User's Meeting-NACRW8

Glyphosate 0.5 ppb to 100 ppb

Page 9: Direct LC/MS/MS Analysis of Glyphosate, AMPA and other Polar · 2017-08-08 · Direct LC/MS/MS Analysis of Glyphosate, AMPA and other Polar Pesticides Jerry Zweigenbaum Agilent User’s

July 27, 2017 Agilent User's Meeting-NACRW9

Glyphosate at 0.5 ppb

Page 10: Direct LC/MS/MS Analysis of Glyphosate, AMPA and other Polar · 2017-08-08 · Direct LC/MS/MS Analysis of Glyphosate, AMPA and other Polar Pesticides Jerry Zweigenbaum Agilent User’s

July 27, 2017 Agilent User's Meeting-NACRW10

AMPA 0.1 to 100 ppb

Page 11: Direct LC/MS/MS Analysis of Glyphosate, AMPA and other Polar · 2017-08-08 · Direct LC/MS/MS Analysis of Glyphosate, AMPA and other Polar Pesticides Jerry Zweigenbaum Agilent User’s

July 27, 2017 Agilent User's Meeting-NACRW11

AMPA at 0.1 ppb

Page 12: Direct LC/MS/MS Analysis of Glyphosate, AMPA and other Polar · 2017-08-08 · Direct LC/MS/MS Analysis of Glyphosate, AMPA and other Polar Pesticides Jerry Zweigenbaum Agilent User’s

1. Liquid-liquid extraction MeCl:water, derivatization with FMOC-Cl

2. Extract with water, cleanup on SAX, elute with 1 N HCl, rotovap to dryness, derivatize with TMOA in glacial acetic acid, dried again and taken up in 9:1 water:methanol

3. Extract with water, pass through Plexa SPE and inject

4. QuPPe

5. Buffered extraction with PAX, elution with 1% formic acid

6. Extract with 50mM acetic acid and 10 mM EDTA, pass through Oasis HLB, inject

7. 50 mM acetic acid 10 mM EDTA, pass through an SEC cartridge

July 27, 2017 Agilent User's Meeting-NACRW12

At this meeting alone

Sample Prep

Page 13: Direct LC/MS/MS Analysis of Glyphosate, AMPA and other Polar · 2017-08-08 · Direct LC/MS/MS Analysis of Glyphosate, AMPA and other Polar Pesticides Jerry Zweigenbaum Agilent User’s

What are your thoughts now??

July 27, 2017 Agilent User's Meeting-NACRW13

Page 14: Direct LC/MS/MS Analysis of Glyphosate, AMPA and other Polar · 2017-08-08 · Direct LC/MS/MS Analysis of Glyphosate, AMPA and other Polar Pesticides Jerry Zweigenbaum Agilent User’s

• Water extraction- no cleanup• Compounds not detected

• Pass through C8-

– Wheat samples, glyphosate and AMPA detected

– Strawberry samples, not detected

• Buffered (pH 8.2 bicarbonate) extraction• 50 mM bicarb

– Ok for wheat

– pH still < 5 for strawberry

• 200 mM bicarb

– Ok wheat

– OK strawberry

July 27, 2017 Agilent User's Meeting-NACRW14

Wheat Flour and Organic Strawberries

Samples

Page 15: Direct LC/MS/MS Analysis of Glyphosate, AMPA and other Polar · 2017-08-08 · Direct LC/MS/MS Analysis of Glyphosate, AMPA and other Polar Pesticides Jerry Zweigenbaum Agilent User’s

• 1 gram sample

• 9 mL of buffer

• Vortex 20 min

• Spin at 4K rpm for 10 min

July 27, 2017 Agilent User's Meeting-NACRW15

Extraction of Wheat and Strawberry

Page 16: Direct LC/MS/MS Analysis of Glyphosate, AMPA and other Polar · 2017-08-08 · Direct LC/MS/MS Analysis of Glyphosate, AMPA and other Polar Pesticides Jerry Zweigenbaum Agilent User’s

• Take 4 mL of extract load onto cartridge

• Wash with water 2 mL

• Wash with methanol 2 mL

• Elute with 1 mL 1% formic acid- neutralize with NH4OH – run on IC/MS

July 27, 2017 Agilent User's Meeting-NACRW16

Cleanup on PAX

Page 17: Direct LC/MS/MS Analysis of Glyphosate, AMPA and other Polar · 2017-08-08 · Direct LC/MS/MS Analysis of Glyphosate, AMPA and other Polar Pesticides Jerry Zweigenbaum Agilent User’s

July 27, 2017 Agilent User's Meeting-NACRW17

Load- 200 mM bicarbonate buffer extract- 50 μL injection

Glufosinate

AMPA

Glyphosate

Page 18: Direct LC/MS/MS Analysis of Glyphosate, AMPA and other Polar · 2017-08-08 · Direct LC/MS/MS Analysis of Glyphosate, AMPA and other Polar Pesticides Jerry Zweigenbaum Agilent User’s

Final Discussions

July 27, 2017 Agilent User's Meeting-NACRW18


Recommended