Direct Steam Generation (DSG) Technology Overview SFERA Summer School 2012 June 28, 2012, Almerá, Spain (Jan) Fabian Feldhoff
Transcript
Page 1: Direct Steam Generation (DSG) - Sollab

Direct Steam Generation (DSG)

Technology Overview

SFERA Summer School 2012June 28, 2012, Almerá, Spain

(Jan) Fabian Feldhoff

Page 2: Direct Steam Generation (DSG) - Sollab

www.DLR.de/SF • Slide 2 > SFERA Summer School 2012 > Direct Steam Generation (DSG) > Fabian Feldhoff > June 28, 2012

STE Status

- Many market players- Need for significant cost reduction

- More automated production and construction- Optimized collector designs- New heat transfer fluids

- Direct Steam Generation (DSG)- Molten Salt

- …

Today: DSGSolarlite: TSE-1

Page 3: Direct Steam Generation (DSG) - Sollab

www.DLR.de/SF • Slide 3 > SFERA Summer School 2012 > Direct Steam Generation (DSG) > Fabian Feldhoff > June 28, 2012

Overview

- Introduction- DSG History- DSG Characteristics and two-phase flow- Plant concepts- Research Overview

- Once-through- Steam Parameters- Operation/Control- Storage concepts

- Final Remarks and Outlook

Solarlite: TSE-1

Page 4: Direct Steam Generation (DSG) - Sollab

www.DLR.de/SF • Slide 4 > SFERA Summer School 2012 > Direct Steam Generation (DSG) > Fabian Feldhoff > June 28, 2012

Parabolic Trough Plants with Oil

Solarlite: TSE-1

Page 5: Direct Steam Generation (DSG) - Sollab

www.DLR.de/SF • Slide 5 > SFERA Summer School 2012 > Direct Steam Generation (DSG) > Fabian Feldhoff > June 28, 2012

Parabolic Trough Plants with Molten Salt

Page 6: Direct Steam Generation (DSG) - Sollab

www.DLR.de/SF • Slide 6 > SFERA Summer School 2012 > Direct Steam Generation (DSG) > Fabian Feldhoff > June 28, 2012

Parabolic Trough Plants with DSG

Solarlite: TSE-1

Page 7: Direct Steam Generation (DSG) - Sollab

www.DLR.de/SF • Slide 7 > SFERA Summer School 2012 > Direct Steam Generation (DSG) > Fabian Feldhoff > June 28, 2012

DSG Advantages and Drawbacks

+ Commercially applied+ One-phase flow+ Easily scalable

- Heat exchanger batteries- T < 400°C- Efficiency/process limit reached- Hazardous to environment

+ No heat exchangers+ High temperatures+ High efficiency+ Non-toxic fluid+ Simple overall configuration- Two-phase flow- Higher control effort- Thermal storage expensive (so far)- Higher temperature gradients

Oil DSG

Page 8: Direct Steam Generation (DSG) - Sollab

www.DLR.de/SF • Slide 8 > SFERA Summer School 2012 > Direct Steam Generation (DSG) > Fabian Feldhoff > June 28, 2012

Milestones in DSG developmentThe very beginnings – DSG was first!

John Ericsson- New York, USA, 1870 and 1883- 3.25-m2-aperture collector- Driving a small 373-W engine.

Frank Shuman- Meadi, Egypt, 1912-1913- 5 collectors 62x4m- driving a steam engine (~40 kW)

used to pump water for irrigation

Fernández-García, A., Zarza, E., Valenzuela, L., et al., 2010,"Parabolic-trough solar collectors and their applications," Renewable and Sustainable Energy Reviews, 14, pp. 1695 - 1721.

Shuman Collector

Page 9: Direct Steam Generation (DSG) - Sollab

www.DLR.de/SF • Slide 9 > SFERA Summer School 2012 > Direct Steam Generation (DSG) > Fabian Feldhoff > June 28, 2012

Milestones in DSG developmentRevival in the 80‘s

Solar One, Barstow, USA- 10 MWe, 425 °C- Once-through boiler- 4 hours storage (sensible)- In operation 1982-1988

Page 10: Direct Steam Generation (DSG) - Sollab

www.DLR.de/SF • Slide 10 > SFERA Summer School 2012 > Direct Steam Generation (DSG) > Fabian Feldhoff > June 28, 2012

Milestones in DSG developmentExperiments with DSG in horizontal tubes

Benson test facility at SiemensGoebel et al: Direkte Dampferzeugung in Parabolrinnensolarkraftwerken. Forschungsverbund Sonnenenergie Themen 96/97, page 110 ff

Page 11: Direct Steam Generation (DSG) - Sollab

www.DLR.de/SF • Slide 11 > SFERA Summer School 2012 > Direct Steam Generation (DSG) > Fabian Feldhoff > June 28, 2012

Milestones in DSG developmentDISS project: 500 m/100 bar/400 °C

Page 12: Direct Steam Generation (DSG) - Sollab

www.DLR.de/SF • Slide 12 > SFERA Summer School 2012 > Direct Steam Generation (DSG) > Fabian Feldhoff > June 28, 2012

Milestones in DSG developmentPlanning of demonstration plant

INDITEP- Application of design

tools- 5 MWe, 410°C / 78 bar- Recirculation with

decentral separators- Another 200m for DISS

Zarza, E., Rojas, M. E., González, L., et al., 2006, "INDITEP: The first pre-commercial DSG solar power plant," Solar Energy, 80 (10), pp. 1270-1276.

Page 13: Direct Steam Generation (DSG) - Sollab

www.DLR.de/SF • Slide 13 > SFERA Summer School 2012 > Direct Steam Generation (DSG) > Fabian Feldhoff > June 28, 2012

Milestones in DSG developmentCommercial tower implementations

PS10: 40 bar saturated steam, 11 MWePS20: 45 bar saturated steam, 20 MWe

http://www.abengoasolar.com/corp/web/en/nuestras_plantas/plantas_en_operacion/espana/PS10_la_primera_torre_comercial_del_mundo.html

Page 14: Direct Steam Generation (DSG) - Sollab

www.DLR.de/SF • Slide 14 > SFERA Summer School 2012 > Direct Steam Generation (DSG) > Fabian Feldhoff > June 28, 2012

Milestones in DSG developmentDSG Component tests at 500 °C

2010/2011Real-DISS test facility112 bar / 500 °C

Concrete storage system

PCM storagesystem

Page 15: Direct Steam Generation (DSG) - Sollab

www.DLR.de/SF • Slide 15 > SFERA Summer School 2012 > Direct Steam Generation (DSG) > Fabian Feldhoff > June 28, 2012

Milestones in DSG developmentLinear Fresnel plants

PE-1: 1 MW, 55 bar, saturated steamPE-2: 30 MW, 55 bar, saturated steamBoth plants with Linear Fresnel technology by Novatec Solar Source: DLR

Page 16: Direct Steam Generation (DSG) - Sollab

www.DLR.de/SF • Slide 16 > SFERA Summer School 2012 > Direct Steam Generation (DSG) > Fabian Feldhoff > June 28, 2012

Milestones in DSG developmentLinear Fresnel plants

Source: Areva Solar

Kimberlina 5 MWe106 bar, 400 °C(higher values announced)Technology by Areva Solar

Page 17: Direct Steam Generation (DSG) - Sollab

www.DLR.de/SF • Slide 17 > SFERA Summer School 2012 > Direct Steam Generation (DSG) > Fabian Feldhoff > June 28, 2012

Milestones in DSG developmentThe first parabolic trough plant with superheating

Source: Solarlite

TSE-1, Thailand5 MWe34 bar, 340 °CTechnology by Solarlite

Page 18: Direct Steam Generation (DSG) - Sollab

www.DLR.de/SF • Slide 18 > SFERA Summer School 2012 > Direct Steam Generation (DSG) > Fabian Feldhoff > June 28, 2012

DSG Status – It‘s commercial!

Topics for industry:- Higher steam parameters (up to 110 bar /500 °C)- Parameter Optimization Pressure and temperature vs. Piping cost- Improvements in plant configurations and costs

Topics for R&D:- Solar Field Optimization Optimized recirculation, once-through- Operation Optimization Start-up, Control- Thermal Energy Storage Costs, Performance- Plant integration options Hybrid, TES

Page 19: Direct Steam Generation (DSG) - Sollab

www.DLR.de/SF • Slide 19 > SFERA Summer School 2012 > Direct Steam Generation (DSG) > Fabian Feldhoff > June 28, 2012

Loop Characteristics > What it’s all about…

Solarlite: TSE-1

Page 20: Direct Steam Generation (DSG) - Sollab

www.DLR.de/SF • Slide 20 > SFERA Summer School 2012 > Direct Steam Generation (DSG) > Fabian Feldhoff > June 28, 2012

Loop Characteristics > Temperature/pressure

- Temperature and pressure along loop (1500m, 500°C/112 bar outlet)

Solarlite: TSE-1

Page 21: Direct Steam Generation (DSG) - Sollab

www.DLR.de/SF • Slide 21 > SFERA Summer School 2012 > Direct Steam Generation (DSG) > Fabian Feldhoff > June 28, 2012

Loop Characteristics > Temperature/Steam Quality

Solarlite: TSE-1

0

100

200

300

400

500

600

0 1 2 3 4 5 6 7 8 9 10Loop length in No of collectors

Tem

pera

ture

in °C

0%

20%

40%

60%

80%

100%

120%

Stea

m Q

ualit

y

TemperatureSteam Quality

Page 22: Direct Steam Generation (DSG) - Sollab

www.DLR.de/SF • Slide 22 > SFERA Summer School 2012 > Direct Steam Generation (DSG) > Fabian Feldhoff > June 28, 2012

Flow Patterns in horizontal tubes

Bubble Flow

Annular Flow

Drop/Spray Flow

Plug Flow

Stratified Flow

Wavy Flow

Slug Flow

Based on VDI Heat Atlas, 10. Aufl. 2006, Hbb

To be avoided

Desired

Page 23: Direct Steam Generation (DSG) - Sollab

www.DLR.de/SF • Slide 23 > SFERA Summer School 2012 > Direct Steam Generation (DSG) > Fabian Feldhoff > June 28, 2012

Loop Characteristics > Temperatureprofile

- Four regionsI. Wetted– heatedII. Wetted– not heatedIII. Dry – not heatedIV. Dry – heated

- Asymmetric temperature profilearound cross section

Heated Region

Wetted Region

III

III IV

Page 24: Direct Steam Generation (DSG) - Sollab

www.DLR.de/SF • Slide 24 > SFERA Summer School 2012 > Direct Steam Generation (DSG) > Fabian Feldhoff > June 28, 2012

Two-phase flow in horizontal pipesInternal heat transfer

case 1

case 2

0 45 90 135 180 225 270 315 360310

315

320

325

330

335

340

345

Fall 1Fall 2

Circumference Angle [°]

Tem

pera

ture

[°C]

Page 25: Direct Steam Generation (DSG) - Sollab

www.DLR.de/SF • Slide 25 > SFERA Summer School 2012 > Direct Steam Generation (DSG) > Fabian Feldhoff > June 28, 2012

Loop Characteristics > Do you understand?

- Question of the day- Which is the most

desirable flow pattern in DSG loops with high steam quality?

- Answer:Annular Flowdue to its complete wetted inner surface.

Page 26: Direct Steam Generation (DSG) - Sollab

www.DLR.de/SF • Slide 26 > SFERA Summer School 2012 > Direct Steam Generation (DSG) > Fabian Feldhoff > June 28, 2012

Two-phase flow in horizontal pipesFlow pattern map

Taitel, Y., and Dukler, A. E., 1976, "A model for predicting flow regime transitions inHorizontal and near horizontal gas-liquid flow," AIChE Journal, 22 (1), pp. 47-55.:

10-3 10-2 10-1 100 101 102 103 104100

101

102

103

104

Martinelli-Parameter X

K K

10-3

10-2

10-1

100

101

T, F

r*

Schichtströmung

Wellenströmung

Ringströmung

Blasenströmung

Schwallströmung

Verdampfungsweg

x .

Annular

Bubble

Desired path of evaporation

Wavy

PlugStratified

Page 27: Direct Steam Generation (DSG) - Sollab

www.DLR.de/SF • Slide 27 > SFERA Summer School 2012 > Direct Steam Generation (DSG) > Fabian Feldhoff > June 28, 2012

Two-phase flow in horizontal pipesPressure loss

0

1

2

3

4

5

6

7

8

1000 1200 1400 1600 1800 2000 2200 2400 2600 2800 3000

Enthalpie [kJ/kg]

dp/d

l [m

bar]

Vorwärmer Verdampfer

Überhitzer

Preheating Evaporation

Super-heating

Pre

ssur

e Lo

ss o

ver l

engt

h (m

bar/m

)

Page 28: Direct Steam Generation (DSG) - Sollab

www.DLR.de/SF • Slide 28 > SFERA Summer School 2012 > Direct Steam Generation (DSG) > Fabian Feldhoff > June 28, 2012

Plant Concepts > How you could run DSG plants

Solarlite: TSE-1

Page 29: Direct Steam Generation (DSG) - Sollab

www.DLR.de/SF • Slide 29 > SFERA Summer School 2012 > Direct Steam Generation (DSG) > Fabian Feldhoff > June 28, 2012

Plant Concepts > Classical approaches

Recirculation

Once-Through(classic)

Injection

Onc

e-Th

roug

h

Eck, M., and Zarza, E., 2002, "Assessment of Operation Modes for Direct Solar Steam Generationin Parabolic Troughs,“ 11th SolarPACES, Zurich, Switzerland

Rec

ircul

atio

n

Page 30: Direct Steam Generation (DSG) - Sollab

www.DLR.de/SF • Slide 30 > SFERA Summer School 2012 > Direct Steam Generation (DSG) > Fabian Feldhoff > June 28, 2012

Plant Concepts > State-of-the-Art Concepts

Recirculation Once-Through

DLR, Feldhoff

Page 31: Direct Steam Generation (DSG) - Sollab

www.DLR.de/SF • Slide 31 > SFERA Summer School 2012 > Direct Steam Generation (DSG) > Fabian Feldhoff > June 28, 2012

Plant Concepts > State-of-the-Art Comparison

+ Very robust operation+ Commercially applied

- Relatively high investment

- Relatively high design effort

+ Easily scalable+ Fast start-up+ Low investment

- Not that robust

- End of evaporation not fixed

Recirculation Once-Through

Based on: Eck, M., and Zarza, E., 2002, "Assessment of Operation Modes for Direct Solar Steam Generation in Parabolic Troughs,“11th SolarPACES Intern. Symposium on Concentrated Solar Power and Chemical Energy Technologies, Zurich, Switzerland

Page 32: Direct Steam Generation (DSG) - Sollab

www.DLR.de/SF • Slide 32 > SFERA Summer School 2012 > Direct Steam Generation (DSG) > Fabian Feldhoff > June 28, 2012

Plant Concepts > Recirculation with central field separators

DLR, Feldhoff/Hirsch

Page 33: Direct Steam Generation (DSG) - Sollab

www.DLR.de/SF • Slide 33 > SFERA Summer School 2012 > Direct Steam Generation (DSG) > Fabian Feldhoff > June 28, 2012

Plant Concepts > Recirculation with decentralseparators

Zarza, E., Rojas, M. E., González, L., et al., 2006, "INDITEP: The first pre-commercial DSG solar power plant," Solar Energy, 80 (10), pp. 1270-1276.

Page 34: Direct Steam Generation (DSG) - Sollab

www.DLR.de/SF • Slide 34 > SFERA Summer School 2012 > Direct Steam Generation (DSG) > Fabian Feldhoff > June 28, 2012

- With 1 or 2 injections- Only one type of loop

Plant Concepts > Once-Through

DLR, Feldhoff

Page 35: Direct Steam Generation (DSG) - Sollab

www.DLR.de/SF • Slide 35 > SFERA Summer School 2012 > Direct Steam Generation (DSG) > Fabian Feldhoff > June 28, 2012

Once-through > The better DSG concept?

Solarlite: TSE-1

Page 36: Direct Steam Generation (DSG) - Sollab

www.DLR.de/SF • Slide 36 > SFERA Summer School 2012 > Direct Steam Generation (DSG) > Fabian Feldhoff > June 28, 2012

Once-through > The DUKE Project

- DUKE: Durchlaufkonzept – Entwicklung und Erprobung(Once-Through Concept Development and Demonstration)

- Goals- Analysis and demonstration of Once-through concept under real

irradiation conditions- Partner

- DLR & Solarlite GmbH- Together with CIEMAT

- Period:- May 1, 2011 to April 30, 2014

Page 37: Direct Steam Generation (DSG) - Sollab

www.DLR.de/SF • Slide 37 > SFERA Summer School 2012 > Direct Steam Generation (DSG) > Fabian Feldhoff > June 28, 2012

Once-through > Demonstration at DISS Facility

BOP und Control room

Installation and storage space

New Solarlite 4600+ collectors (3x 100m)

North

Page 38: Direct Steam Generation (DSG) - Sollab

www.DLR.de/SF • Slide 38 > SFERA Summer School 2012 > Direct Steam Generation (DSG) > Fabian Feldhoff > June 28, 2012

Once-through > Main Changes DISS Solar Field

New BOP injection

New SH injection

Relocation of inlet valves

New injection instrumentation

New balljointsNew receivers

Temperature along end of evaporation and around cross sections

Page 39: Direct Steam Generation (DSG) - Sollab

www.DLR.de/SF • Slide 39 > SFERA Summer School 2012 > Direct Steam Generation (DSG) > Fabian Feldhoff > June 28, 2012

Once-through > Main Demonstration Experiments

- Component qualification

- Design and validation of dynamic models

- Test and validation of control concepts

System evaluation of once-through concept

Page 40: Direct Steam Generation (DSG) - Sollab

www.DLR.de/SF • Slide 40 > SFERA Summer School 2012 > Direct Steam Generation (DSG) > Fabian Feldhoff > June 28, 2012

Parameter Optimization > One step ahead…

Page 41: Direct Steam Generation (DSG) - Sollab

www.DLR.de/SF • Slide 41 > SFERA Summer School 2012 > Direct Steam Generation (DSG) > Fabian Feldhoff > June 28, 2012

Parameter Optimization > Why that?

- Power Block:Carnot efficiency increases with temperature

- Solar field:efficiency decreases with temperature

Find the optimum Look at real-life

thermodynamics and costs together!

Page 42: Direct Steam Generation (DSG) - Sollab

www.DLR.de/SF • Slide 42 > SFERA Summer School 2012 > Direct Steam Generation (DSG) > Fabian Feldhoff > June 28, 2012

Parameter Optimization > Power Block

0.30

0.32

0.34

0.36

0.38

0.40

0.42

350 375 400 425 450 475 500 525Main Steam Temperature [°C]

Gro

ss P

ower

Blo

ck E

ffici

ency

[-]

8'124

11'373

Hea

t Rat

e [B

TU/k

Wh e

l]

120 bar100 bar

60 bar

40 bar

HTF Reference

Feldhoff, J. F., Benitez, D., Eck, M., et al., 2010, "Economic Potential of Solar Thermal Power PlantsWith Direct Steam Generation Compared With HTF Plants," Journal of Solar Energy Engineering, 132 (4), pp. 041001-9.

Page 43: Direct Steam Generation (DSG) - Sollab

www.DLR.de/SF • Slide 43 > SFERA Summer School 2012 > Direct Steam Generation (DSG) > Fabian Feldhoff > June 28, 2012

Parameter Optimization > Solar Field (Rec.)

57.5

58.0

58.5

59.0

59.5

60.0

60.5

61.0

61.5

350 375 400 425 450 475 500 525Live Steam Temperature [°C]

Mea

n S

olar

Fie

ld E

ffici

ency

[%]

100 bar60 bar

40 bar

Feldhoff, J. F., Benitez, D., Eck, M., et al., 2010, "Economic Potential of Solar Thermal Power PlantsWith Direct Steam Generation Compared With HTF Plants," Journal of Solar Energy Engineering, 132 (4), pp. 041001-9.

Page 44: Direct Steam Generation (DSG) - Sollab

www.DLR.de/SF • Slide 44 > SFERA Summer School 2012 > Direct Steam Generation (DSG) > Fabian Feldhoff > June 28, 2012

Parameter Optimization > Heat Balance Tool

Page 45: Direct Steam Generation (DSG) - Sollab

www.DLR.de/SF • Slide 45 > SFERA Summer School 2012 > Direct Steam Generation (DSG) > Fabian Feldhoff > June 28, 2012

Parameter Optimization > Overall efficiencies

- Comparison of annual net efficiencies

- Thermodynamics: pressure increase more efficient than temperature increase

- Costs: piping for higher pressure more expensive

Feldhoff, J. F., Benitez, D., Eck, M., et al., 2010, "Economic Potential of Solar Thermal Power PlantsWith Direct Steam Generation Compared With HTF Plants," Journal of Solar Energy Engineering, 132 (4), pp. 041001-9.

Page 46: Direct Steam Generation (DSG) - Sollab

www.DLR.de/SF • Slide 46 > SFERA Summer School 2012 > Direct Steam Generation (DSG) > Fabian Feldhoff > June 28, 2012

System Analysis > Comparison with oil trough

Annual Yield Results for 100 MWe, Daggett (USA), 9h of thermal energy storage (TES):- DSG solar field size -5.3 %- DSG net electricity output +2.5 to +2.9 %- Net plant efficiency +8.3 %

Feldhoff, J. F., Schmitz, K., Eck, M., et al., 2012, "Comparative system analysis of direct steam generation and synthetic oilparabolic trough power plants with integrated thermal storage," Solar Energy, 86 (1), pp. 520-530.

Page 47: Direct Steam Generation (DSG) - Sollab

www.DLR.de/SF • Slide 47 > SFERA Summer School 2012 > Direct Steam Generation (DSG) > Fabian Feldhoff > June 28, 2012

System Analysis > Cost Comparison to Oil Trough

- 100 MWe, 9h TES, Daggett/USA- Large solar fields sizes (450 MWth and more) are close too current

design pressure limits Choose DSG for sizes up to about 50 MWe and long term storage

- TES not yet commercially available Concepts under development Short term projects should focus on short term storage or hybridisation Oil trough without TES at least 5-10% more expensive than DSG

Feldhoff, J. F., Schmitz, K., Eck, M., et al., 2012, "Comparative system analysis of direct steamgeneration and synthetic oil parabolic trough power plants with integrated thermal storage," Solar Energy, 86 (1), pp. 520-530.

Page 48: Direct Steam Generation (DSG) - Sollab

www.DLR.de/SF • Slide 49 > SFERA Summer School 2012 > Direct Steam Generation (DSG) > Fabian Feldhoff > June 28, 2012

Control > The secret to better performance

Page 49: Direct Steam Generation (DSG) - Sollab

www.DLR.de/SF • Slide 50 > SFERA Summer School 2012 > Direct Steam Generation (DSG) > Fabian Feldhoff > June 28, 2012

Control > Solar Field

- One loop simulated- Cascaded superheating

temperature controller

Higher temperature gradients than in normal multiple loop plant

Birnbaum, J., Feldhoff, J. F., Fichtner, M., et al., 2011, "Steam temperature stability in adirect steam generation solar power plant," Solar Energy, 85 (4), pp. 660-668.

Page 50: Direct Steam Generation (DSG) - Sollab

www.DLR.de/SF • Slide 51 > SFERA Summer School 2012 > Direct Steam Generation (DSG) > Fabian Feldhoff > June 28, 2012

Control > Adaptive Controllers

- Adaptive PI controllers with DNI-dependent feedforward are reliable for recirculation and injection mode [1, 2]

[1]: Valenzuela, L., Zarza, E., Berenguel, M., et al., 2005, "Control concepts for direct steam generation in parabolic troughs," Solar Energy, 78 (2), pp. 301-311.[2]: Eck, M., 2001, Die Dynamik der solaren Direktverdampfung und Überhitzung in Parabolrinnenkollektoren, VDI Verlag Düsseldorf.

Graphics: DLR, Feldhoff/Trebing

Parameter range for adaptive PI controller

0.2 0.4 0.6 0.8 1 1.2 1.4 1.6 200

400

600

800

1000

50

100

150

200

250

300

350

qdni

X: 1.367Y: 850Z: 80.13

X: 1.04Y: 650Z: 105.3

time constant of adaptive PI controler

mdot0

T i

nominal state

0.2 0.4 0.6 0.8 1 1.2 1.4 1.6 200

400

600

800

1000

-2.5

-2

-1.5

-1

-0.5

0

x 10-3

qdni

X: 1.367Y: 850Z: -0.001765

gain of adaptive PI controler

X: 1.04Y: 650Z: -0.001343

mdot0

Kp

nominal state

Page 51: Direct Steam Generation (DSG) - Sollab

www.DLR.de/SF • Slide 52 > SFERA Summer School 2012 > Direct Steam Generation (DSG) > Fabian Feldhoff > June 28, 2012

Control > Experience from real recirculation plants

- Outlet temperature can be kept very stable even with easy controllers- Multiple loops and header piping smooth the temperature significantly no problems in recirculation plants very robust operation in recirculation plants

Page 52: Direct Steam Generation (DSG) - Sollab

www.DLR.de/SF • Slide 53 > SFERA Summer School 2012 > Direct Steam Generation (DSG) > Fabian Feldhoff > June 28, 2012

DSG TES > Upgrading STE Plants

- TES = Thermal Energy Storage

Page 53: Direct Steam Generation (DSG) - Sollab

www.DLR.de/SF • Slide 54 > SFERA Summer School 2012 > Direct Steam Generation (DSG) > Fabian Feldhoff > June 28, 2012

DSG TES > Sytem Overview

Birnbaum, J., Eck, M., Fichtner, M., et al., 2008, "A Direct Steam Generation Solar Power Plantwith Integrated Thermal Storage," 14th Bienial SolarPACES Symposium, Las Vegas, USA.

Page 54: Direct Steam Generation (DSG) - Sollab

www.DLR.de/SF • Slide 55 > SFERA Summer School 2012 > Direct Steam Generation (DSG) > Fabian Feldhoff > June 28, 2012

DSG TES > Storage developmentPhase change material storagePhase change materialDemonstrated at DLR:- NaNO3 - KNO3 - NaNO2 142 °C- LiNO3 - NaNO3 194 °C- NaNO3 - KNO3 222 °C- NaNO3 306 °CExperimental validation- 5 test modules with 140 – 2000 kg PCM- Worlds largest high temperature latent heat

storage with 14 tons of NaNO3 (700 kWh) operating since 2010

DLR-TT

Page 55: Direct Steam Generation (DSG) - Sollab

www.DLR.de/SF • Slide 56 > SFERA Summer School 2012 > Direct Steam Generation (DSG) > Fabian Feldhoff > June 28, 2012

DSG TES > Plant Integration

DLR, FF

Page 56: Direct Steam Generation (DSG) - Sollab

www.DLR.de/SF • Slide 57 > SFERA Summer School 2012 > Direct Steam Generation (DSG) > Fabian Feldhoff > June 28, 2012

DSG TES > Plant Integration

Project DETOP

Variant 1:- PH: Concrete- SG: PCM- SH: Concrete

Variant 2:- PH: Salt- SG: PCM- SH: Salt

Variant 3:- PH: PCM- SG: PCM- SH: Salt

Page 57: Direct Steam Generation (DSG) - Sollab

www.DLR.de/SF • Slide 58 > SFERA Summer School 2012 > Direct Steam Generation (DSG) > Fabian Feldhoff > June 28, 2012

DSG TES > Power Block Operation

Birnbaum, J., Eck, M., Fichtner, M., et al., 2008, "A Direct Steam Generation Solar Power Plantwith Integrated Thermal Storage," 14th Bienial SolarPACES Symposium, Las Vegas, USA.

Page 58: Direct Steam Generation (DSG) - Sollab

www.DLR.de/SF • Slide 59 > SFERA Summer School 2012 > Direct Steam Generation (DSG) > Fabian Feldhoff > June 28, 2012

Outlook and Market > Somebody must build it…

Solarlite: TSE-1

Page 59: Direct Steam Generation (DSG) - Sollab

www.DLR.de/SF • Slide 60 > SFERA Summer School 2012 > Direct Steam Generation (DSG) > Fabian Feldhoff > June 28, 2012

DSG Companies

- Solarlite, Germany- Recirculation, trough, superheated steam

- Novatec Solar, Germany- Recirculation, Fresnel, saturated steam, probably superheated in future

- Areva Solar, France/Australia- Once-through, Fresnel with multiple tubes/counter flow receiver,

exact parameters are unknown- Solar Power Group, Germany

- Recirculation, Fresnel, no commercial plant realized so far- Abengoa Solar, Spain

- Recirculation, trough, superheated steam, only tests at Solucar

Solarlite: TSE-1

Page 60: Direct Steam Generation (DSG) - Sollab

www.DLR.de/SF • Slide 60 > SFERA Summer School 2012 > Direct Steam Generation (DSG) > Fabian Feldhoff > June 28, 2012

Final Remarks on DSG

- DSG has reached commercial status!- For short to mid-term:

- STE plants without or with small storage- Integrated Solar Combined Cycle (ISCC) or fuel

saver plants (Don’t use oil for that!)- For long term DSG perspective:

- Development of economic PCM storage system- Solar field optimization- Overall parameter optimization including TES

- There is still a need for research- There is still a need for a reliable and detailed

comparison of alternative STE configurationsSolarlite: TSE-1

Solarlite: TSE-1

Page 61: Direct Steam Generation (DSG) - Sollab

www.DLR.de/SF • Slide 62 > SFERA Summer School 2012 > Direct Steam Generation (DSG) > Fabian Feldhoff > June 28, 2012

Questions and Discussion…

- Contact: [email protected]

By Ron Tandberg

Page 62: Direct Steam Generation (DSG) - Sollab

www.DLR.de/SF • Slide 63 > SFERA Summer School 2012 > Direct Steam Generation (DSG) > Fabian Feldhoff > June 28, 2012

DSG History > Add-on

- An uncomplete list of projects and contents…

Page 63: Direct Steam Generation (DSG) - Sollab

www.DLR.de/SF • Slide 64 > SFERA Summer School 2012 > Direct Steam Generation (DSG) > Fabian Feldhoff > June 28, 2012

DSG activities 1/4

Duration Partner Target

GUDE 1993-96 DLR, Siemens, TUM, ZSW

Thermo-hydraulic effects inhorizontal receiver tubes

PRODISS/ARDISS

1996-99 DLR Modelling, simulation and control ofa collector loop

DISS I/II 1996-2002 CIEMAT, DLR, Flagsol, Iberdrola, ZSW, Siemens/KWU

Planing and erection of DISS plant Prove of concept Evaluation of different operation

concepts Validation and improvement of

modeling capabilities

Page 64: Direct Steam Generation (DSG) - Sollab

www.DLR.de/SF • Slide 65 > SFERA Summer School 2012 > Direct Steam Generation (DSG) > Fabian Feldhoff > June 28, 2012

DSG activities 2/4

Duration Partner TargetINDITEP 2002-05 CIEMAT, DLR,

Flagsol, Iberdrola, Siemens, ZSW

Detailed engineering of a demo loop Component development (separator,

ball-joints, receiver) Socio-economic analysis

SOLDI 2004-06 DLR, (Siemens) Evaluation of separation concepts Process heat generation Dynamic model library

DISSTOR 2004-07 DLR, Züblin, SGL Carbon, CIEMAT, Iberdrola, Flagsol, CNRS, Solucar

Development, erection and operationof a latent heat storage system

Page 65: Direct Steam Generation (DSG) - Sollab

www.DLR.de/SF • Slide 66 > SFERA Summer School 2012 > Direct Steam Generation (DSG) > Fabian Feldhoff > June 28, 2012

DSG activities 3/4

Duration Partner TargetDIVA 2005-07 SCHOTT, DLR,

(Flagsol, KK&K) Receiver development for 500 °C Detailed system analysis

ITES 2006-09 DLR, Züblin, Siemens

Planing, erection and operation of a integrated storage system

Optimized control strategiesFRESDEMO 2006-08 MAN, SPG, (DLR,

FhG-ISE, PSE) Planing, erection and operation of a

Fresnel collector with DSG Qualification of the collector

Page 66: Direct Steam Generation (DSG) - Sollab

www.DLR.de/SF • Slide 67 > SFERA Summer School 2012 > Direct Steam Generation (DSG) > Fabian Feldhoff > June 28, 2012

DSG activities 4/4

Duration Partner TargetDETOP 2009-10 Solar Millennium,

Flagsol, DLR, Schott Solar, Züblin

Preparation of a demo plant Detailed system analysis

FRESDEMO 2

2009-13 Schott Solar, DLR, Novatec Solar, FhG-ISE

Optimization of Linear Fresnel Technology and operation

DUKE 2011-14 DLR, Solarlite (CIEMAT)

Extension of DISS plant to 1000 m Demonstration of once-through

operation