May cause irritation to eyes and skin. IF ON SKIN: Wash with plenty of soap and water. IF SWALLOWED: rinse mouth. Do not induce vomiting. IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing. Get medical advice/attention if you feel unwell. Protected by U.S. Patent Nos: 6,293,319 and 6,186,197 HVAC/R Directions 1. To charge the hose assembly and remove the air, first connect the applicator to the hose assembly. When charging the first time, rotate applicator dial 1/2 turn counter clockwise. While depressing the center pin in the anti-blowback valve, depress the calibrated plunger until a small amount of dye exits the hose. 2. Attach hose assembly to the low side fitting of the A/C system. 3. Pre-set the dialer to the amount of dye to be injected into the system (see chart). 4. With the A/C system running, hold the flange between your index and middle fingers and press the plunger with your thumb until the plunger is stopped by the flange. 5. Continue running the system until the dye has mixed thoroughly. 6. Use the UV light to locate leaks. Application System size in lbs. of refrigerant Dye Amount Small appliance and auto A/C Up to 4.9 (2.22 kgs.) .25 oz (7.5 ml) A/C or refrigerant systems Up to 25 lbs. (11.34 kgs) 0.5 oz (15 ml) Larger systems Above 25 lbs. (11.34 kgs) 0.5 oz (15 ml) per gal. of oil Syringe not rated for pressures higher than 80 psi All refrigerant hose assembly with anti-blowback valve Flange Check valve Calibrated plunger Dialer 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.TestEquipmentDepot.com Test Equipment Depot - 800.517.8431 - 99 Washington Street Melrose, MA 02176 TestEquipmentDepot.com
Transcript

May cause irritation to eyes and skin. IF ON SKIN: Wash with plenty of soap and water. IF SWALLOWED: rinse mouth. Do not induce vomiting. IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing. Get medical advice/attention if you feel unwell.

Protected by U.S. Patent Nos: 6,293,319 and 6,186,197

HVAC/R Directions

1. To charge the hose assembly and remove the air, firstconnect the applicator to the hose assembly. Whencharging the first time, rotate applicator dial 1/2 turncounter clockwise. While depressing the center pin inthe anti-blowback valve, depress the calibrated plungeruntil a small amount of dye exits the hose.

2. Attach hose assembly to the low side fitting of theA/C system.

3. Pre-set the dialer to the amount of dye to be injected intothe system (see chart).

4. With the A/C system running, hold the flange between your index and middle fingers and press the plunger with your thumb until the plunger is stopped by the flange.

5. Continue running the system until the dye has mixed thoroughly.

6. Use the UV light to locate leaks.

Application System size in lbs. of refrigerant Dye Amount

Small appliance and auto A/C

Up to 4.9 (2.22 kgs.) .25 oz (7.5 ml)

A/C or refrigerant systems

Up to 25 lbs. (11.34 kgs)

0.5 oz (15 ml)

Larger systems Above 25 lbs. (11.34 kgs)

0.5 oz (15 ml) per gal. of oil

Syringe not rated for pressures higher than 80 psi

All refrigerant hose assembly with anti-blowback valve

FlangeCheck valve

Calibrated plunger Dialer

99 Washington Street Melrose, MA 02176 Phone 781-665-1400Toll Free 1-800-517-8431