+ All Categories
Home > Documents > Distribution Boxes Tech Data - Rockwell Automation · 2019-07-24 · Port 1 Pin 4 Port 1 Pin 4 1...

Distribution Boxes Tech Data - Rockwell Automation · 2019-07-24 · Port 1 Pin 4 Port 1 Pin 4 1...

Date post: 23-May-2020
Category:
Upload: others
View: 3 times
Download: 0 times
Share this document with a friend
12
Technical Data Distribution Boxes Bulletin Numbers 898D, 898H, 898P Topic Page DC Micro Style Distribution Boxes 2 Four-Pin, One Signal per Port Cable Connector Distribution Box 2 Four-Pin, Two Signals per Port Cable Connector Distribution Box 3 Four-Pin, One Signal per Port Cable with Terminal Block Connector Distribution Box 5 Four-Pin, One or Two Signals per Port Cable with M23 Main Connector Distribution Box 6 Pico Style Distribution Boxes 8 Three-Pin, Cable Connector Distribution Box 8 Three-Pin, DC Micro Main Connector Distribution Box 10 IDC Style Distribution Boxes 11 One Signal per Port Cable Connector Distribution Box 11
Transcript
Page 1: Distribution Boxes Tech Data - Rockwell Automation · 2019-07-24 · Port 1 Pin 4 Port 1 Pin 4 1 Port 2 Pin 4 Port 2 Pin 4 2 Port 3 Pin 4 Port 3 Pin 4 3 Port 4 Pin 4 Port 4 Pin 4

Technical Data

Distribution BoxesBulletin Numbers 898D, 898H, 898P

Topic Page

DC Micro Style Distribution Boxes 2

Four-Pin, One Signal per Port Cable Connector Distribution Box 2

Four-Pin, Two Signals per Port Cable Connector Distribution Box 3

Four-Pin, One Signal per Port Cable with Terminal Block Connector Distribution Box 5

Four-Pin, One or Two Signals per Port Cable with M23 Main Connector Distribution Box 6

Pico Style Distribution Boxes 8

Three-Pin, Cable Connector Distribution Box 8

Three-Pin, DC Micro Main Connector Distribution Box 10

IDC Style Distribution Boxes 11

One Signal per Port Cable Connector Distribution Box 11

Page 2: Distribution Boxes Tech Data - Rockwell Automation · 2019-07-24 · Port 1 Pin 4 Port 1 Pin 4 1 Port 2 Pin 4 Port 2 Pin 4 2 Port 3 Pin 4 Port 3 Pin 4 3 Port 4 Pin 4 Port 4 Pin 4

Distribution Boxes

DC Micro Style Distribution Boxes

Four-Pin, One Signal per Port Cable Connector Distribution Box

Figure 1 - Approximate Dimensions

Figure 2 - Typical Wiring Diagram(s)

Table 1 - Specifications

Certifications UL recognized and CSA certified

MechanicalMaterial Gray Pocan

Connector insert material PBT

Receptacle shell material Zinc diecast with nickel plating

Contact material Gold-plated palladium/nickel

Cable type Oil-resistant black PUR/PVC jacket, (3) 18 AWG stranded copper, (4, 6, or 8) 22 AWG flex rated for 1 million cycles

Cable diameter• 4-port: 7.5 mm (0.30 in.)• 6-port: 7.8 mm (0.31 in.)• 8-port: 8.2 mm (0.32 in.)

EnvironmentalEnclosure type rating IP67, NEMA 6P, 1200 psi (8270 kPa) washdown

Operating temperature -20…+90 °C (-4…+194 °F)

Eight-port DC Micro Distribution Box

107 (4.21)73 (2.87)

60(2.36)

39(1.54)

4.5(0.18)

25(0.98)

7, 9, or 11conductor cable

33(1.3)

102 (4.02) 4-port127 (5.0) 6-port

152 (5.98) 8-port

13.5 (0.53)

16.5 (0.65)

18 (0.71)

898D

-54P

T-B5

Allen

-Bra

dley

-

5.0(0.20)

Allen

-Bra

dley

Dimensions are shown in mm (in.). Illustrations are not drawn to scale.Dimensions shown are not intended to be used for installation purposes.

NPN NPN

PNP PNP

NPN NPN NPN

51

51

51

5

43 4 3 3 4 3 4

15

15

15

15

13 4 3 4 3 4 3 4

4-Port

Gree

n/Ye

llow

(+)B

rown

(-)Bl

ue Whit

e

Gree

n

(PE)

PNP

NPN

PNP

NPN

PNP PNP PNP PNP

NPN

Yello

w

Grey

Pink

Red

Blac

k

Viole

t

6-Port 8-Port

1 2 3 4 5 6 7 8

Wiring diagram shows both PNP and NPN wiring. Actual units use PNP LED, NPN LED or neither.

Table 2 - Mating Components and Accessories

Description Cat. No.

Device patchcords 889D-F4ACDM-x(3)

(3) Replace x with 1 [1 m (3.28 ft)], 2 [2 m (6.56 ft)], 3 [3 m (9.84 ft)], 5 [5 m (16.40 ft)], or 10 [10 m (32.81 ft)] for standard cable lengths.

Field attachable connectors 871A-TS4-DM

IDC field attachable connectors 889D-M4DC-H

Sealing caps(1)

(1) Two provided with box.

1485A-M12

Labels(2)

(2) One set provided with box.

1492-MS9X20

Table 3 - Pinout

Device Connection Main Connection

Ports (4-Pin Female) Cable Connector

4-Port 6-Port 8-Port —

Ground Ground Ground Green/Yellow

(+) All Ports Pin 1 (+) All Ports Pin 1 (+) All Ports Pin 1 Brown

(-) All Ports Pin 3 (-) All Ports Pin 3 (-) All Ports Pin 3 Blue

Port 1 Pin 4 Port 1 Pin 4 Port 1 Pin 4 White

Port 2 Pin 4 Port 2 Pin 4 Port 2 Pin 4 Green

Port 3 Pin 4 Port 3 Pin 4 Port 3 Pin 4 Yellow

Port 4 Pin 4 Port 4 Pin 4 Port 4 Pin 4 Gray

— Port 5 Pin 4 Port 5 Pin 4 Rose

— Port 6 Pin 4 Port 6 Pin 4 Red

— — Port 7 Pin 4 Black

— — Port 8 Pin 4 Violet

Table 4 - Product Selection

Ports Illumination Assembly Rating Cat. No.(1)

(1) Replace x with 5 [5 m (16.40 ft)] or 10 [10 m (32.81 ft)] for standard cable lengths.

4 Port

No LED

10…30V DC,2 A per channel/ 10 A total

898D-54PT-Bx

PNP LED 898D-P54PT-Bx

NPN LED 898D-N54PT-Bx

6 Port

No LED 898D-56PT-Bx

PNP LED 898D-P56PT-Bx

NPN LED 898D-N56PT-Bx

8 Port

No LED 898D-58PT-Bx

PNP LED 898D-P58PT-Bx

NPN LED 898D-N58PT-Bx

Device patchcords (straight to straight) 889D-F4ACDM-y(2)

(2) Replace y with 1 [1 m (3.28 ft)], 2 [2 m (6.56 ft)], 3 [3 m (9.84 ft)], 5 [5 m (16.40 ft)], or 10 [10 m (32.81 ft)] for standard cable lengths.

5

4 3

1

2

2 Rockwell Automation Publication 898-TD001B-EN-P - June 2019

Page 3: Distribution Boxes Tech Data - Rockwell Automation · 2019-07-24 · Port 1 Pin 4 Port 1 Pin 4 1 Port 2 Pin 4 Port 2 Pin 4 2 Port 3 Pin 4 Port 3 Pin 4 3 Port 4 Pin 4 Port 4 Pin 4

Distribution Boxes

Four-Pin, Two Signals per Port Cable Connector Distribution Box

Figure 3 - Approximate Dimensions

Figure 4 - Typical Wiring Diagram

Table 5 - Specifications

Certifications UL recognized and CSA certified

MechanicalMaterial Gray Pocan

Connector insert material PBT

Receptacle shell material Zinc diecast with nickel plating

Contact material Gold-plated palladium/nickel

Cable type Oil-resistant black PUR/PVC jacket, (3) 18 AWG stranded copper, (8 or 16) 22 AWG flex rated for 1 million cycles

Cable diameter • 4-port: 8.2 mm (0.32 in.)• 8-port: 9.7 mm (0.38 in.)

EnvironmentalEnclosure type rating IP67, NEMA 6P, 1200 psi (8270 kPa) washdown

Operating temperature -20…+90 °C (-4…+194 °F)

Eight-port DC Micro Distribution Box

60(2.36)

107 (4.21)73 (2.87)

39(1.54)

4.5(0.18)

25(0.98)

33(1.30)

102 (4.02) 4-port127 (5.0) 6-port

152 (5.98) 8-port

13.5(0.53)

16.5 (0.65)

18(0.71)

-

5.0(0.20)

ALLE

N-BR

ADLE

Y

ALLE

N-BR

ADLE

Y

11 or 19conductor

table

Dimensions are shown in mm (in.). Illustrations are not drawn to scale.

51

3

1

4

51

3 4

2

51

51

3 4

3

3 4

4

51

5

3 4

5

3

6

15

15

134 4

7

3 4

8

2 2 2 2 2 2 2 2

4-Port

Gree

n-Ye

llow

(+)B

rown

(-)Bl

ueW

hite

Gree

n

(PE)

PNP

Yello

w

Gray

Pink

Red

Blac

k

Viol

et

6-Port 8-Port

PNP

PNP

PNP

PNP

PNP

PNP

PNP

PNP

PNP

PNP

PNP

PNP

PNP

PNP

PNP

Gray

-Pin

k

Red-

Blue

Whi

te-G

reen

Brow

n-Gr

een

Whi

te-Y

ellow

Yello

w0-B

rown

Whi

te-G

ray

Gray

-Bro

wn

Wiring diagram shows PNP wiring. Actual units use PNP LED or no LED.

Table 6 - Mating Components and Accessories

Description Cat. No.

Device patchcords 889D-F4ACDM-x(3)

(3) Replace x with 1 [1 m (3.28 ft)], 2 [2 m (6.56 ft)], 3 [3 m (9.84 ft)], 5 [5 m (16.40 ft)], or 10 [10 m (32.81 ft)] for standard cable lengths.

Field attachable connectors 871A-TS4-DM

IDC field attachable connectors 889D-M4DC-H

V-cables 879D-F4ACDM-x(3)

Splitter 879D-F4DM

Sealing caps(1)

(1) Two provided with box.

1485A-M12

Labels(2)

(2) One set provided with box.

1492-MS9X20

Table 7 - Pinout

Device Connection Main Connection

Ports (4-Pin Female) Cable Connector

4-Port 8-Port —

Ground Ground Green-Yellow

(+) All Ports Pin 1 (+) All Ports Pin 1 Brown

(-) All Ports Pin 3 (-) All Ports Pin 3 Blue

Port 1 Pin 4 Port 1 Pin 4 White

Port 2 Pin 4 Port 2 Pin 4 Green

Port 3 Pin 4 Port 3 Pin 4 Yellow

Port 4 Bin 4 Port 4 Pin 4 Gray

— Port 5 Pin 4 Rose

— Port 6 Pin 4 Red

— Port 7 Pin 4 Black

— Port 8 Pin 4 Violet

Port 1 Pin 2 Port 1 Pin 2 Gray-Pink

Port 2 Pin 2 Port 2 Pin 2 Red-Blue

Port 3 Pin 2 Port 3 Pin 2 White-Green

Port 4 Pin 2 Port 4 Pin 2 Brown-Green

— Port 5 Pin 2 White-Yellow

— Port 6 Pin 2 Yellow-Brown

— Port 7 Pin 2 White-Gray

— Port 8 Pin 2 Gray-Brown

5

4 3

1

2

Rockwell Automation Publication 898-TD001B-EN-P - June 2019 3

Page 4: Distribution Boxes Tech Data - Rockwell Automation · 2019-07-24 · Port 1 Pin 4 Port 1 Pin 4 1 Port 2 Pin 4 Port 2 Pin 4 2 Port 3 Pin 4 Port 3 Pin 4 3 Port 4 Pin 4 Port 4 Pin 4

Distribution Boxes

Table 8 - Product Selection

Ports Illumination Assembly Rating Cat. No.(1)(2)

(1) Replace x with 5 [5 m (16.40 ft)] or 10 [10 m (32.81 ft)] for standard cable lengths.(2) Replace y with 1 [1 m (3.28 ft)], 2 [2 m (6.56 ft)], 3 [3 m (9.84 ft)], 5 [5 m (16.40 ft)], or 10 [10 m (32.81 ft)]

for standard cable lengths.

4 PortNo LED

10…30V DC, 2 A per channel/ 10 A total

898D-54DT-Bx

PNP LED 898D-P54DT-Bx

8 PortNo LED 898D-58DT-Bx

PNP LED 898D-P58DT-Bx

Device patchcords (straight to straight) 889D-F4ACDM-y

Device V-cables (straight) 879D-F4ACDM-y

4 Rockwell Automation Publication 898-TD001B-EN-P - June 2019

Page 5: Distribution Boxes Tech Data - Rockwell Automation · 2019-07-24 · Port 1 Pin 4 Port 1 Pin 4 1 Port 2 Pin 4 Port 2 Pin 4 2 Port 3 Pin 4 Port 3 Pin 4 3 Port 4 Pin 4 Port 4 Pin 4

Distribution Boxes

Four-Pin, One Signal per Port Cable with Terminal Block Connector Distribution Box

Figure 5 - Approximate Dimensions

Figure 6 - Typical Wiring Diagram(s)

Table 9 - Specifications

Certifications UL recognized and CSA certified

MechanicalMaterial Gray Pocan

Connector insert material PBT

Receptacle shell material Zinc diecast with nickel plating

Contact material Gold-plated palladium/nickel

Cable gland M20 mounting thread

Cable diameter 6…10 mm (0.24…0.39 in.)

EnvironmentalEnclosure type rating IP67, 1200 psi (8270 kPa) washdown

Operating temperature -20…+90 °C (-4…+194 °F)

Eight-port DC Micro Distribution Box

107 (4.21)73 (2.87) 4.5

(0.18)

41.5(1.63)

33(1.30)5.0

(0.20)

ALLE

N-BR

ADLE

Y

13.5(0.53)

16.5 (0.65)

18(0.71)

ALLE

N-BR

ADLE

Y

13.5(0.53)

39(1.54)

898D

-54P

T-T B

60(2.36)

102 (4.02) 4-port

127 (5.0) 6-port

152 (5.98) 8-port

Dimensions are shown in mm (in.). Illustrations are not drawn to scale.Dimensions shown are not intended to be used for installation purposes.

Blue

-- --

3

5

4

1

1

5

31

4

5

3 4

2 3

15

3 4

15

3

4 5

1

4

5

3 4

1

6

4

5

31

5

31

4

7 8

4-Port

1 2(PE)

NPN

3 4 5 6 7 8

6-Port 8-Port

PNP

NPN

PNP

NPN

PNP

NPN

PNP

NPN

PNP

NPN

PNP

NPN

PNP

NPN

PNP

++

1917U2U1

++

1820U1U2

Red

Wiring diagram shows both PNP and NPN wiring. Actual units use PNP LED, NPN LED or neither.

Table 10 - Mating Components and Accessories

Description Cat. No.

Device patchcords 889D-F4ACDM-x(3)

(3) Replace x with 1 [1 m (3.28 ft)], 2 [2 m (6.56 ft)], 3 [3 m (9.84 ft)], 5 [5 m (16.40 ft)], or 10 [10 m (32.81 ft)] for standard cable lengths.

Field attachable connectors 871A-TS4-DM

IDC field attachable connectors 889D-M4DC-H

Sealing caps(1)

(1) Two provided with box.

1485A-M12

Labels(2)

(2) One set provided with box.

1492-MS9X20

Table 11 - Pinout

Device Connection Main Connection

Ports (4-Pin Female) Terminal Block Connector

4-Port 8-Port —

Ground Ground PE

(+) Odd Ports Pin 1 (+) Odd Ports Pin 1 17

(+) Even Ports Pin 1 (+) Even Ports Pin 1 19

(-) Odd Ports Pin 3 (-) Odd Ports Pin 3 18

(-) Even Ports Pin 3 (-) Even Ports Pin 3 20

Port 1 Pin 4 Port 1 Pin 4 1

Port 2 Pin 4 Port 2 Pin 4 2

Port 3 Pin 4 Port 3 Pin 4 3

Port 4 Pin 4 Port 4 Pin 4 4

— Port 5 Pin 4 5

— Port 6 Pin 4 6

— Port 7 Pin 4 7

— Port 8 Pin 4 8

Table 12 - Product Selection

Ports Illumination Assembly Rating Cat. No.

4 Port No LED

10…30V DC, 2 A per channel/ 10 A total or8 A per input when 2 inputs are used

898D-54PT-T

PNP LED 898D-P54PT-T

NPN LED 898D-N54PT-T

8 Port No LED 898D-58PT-T

PNP LED 898D-P58PT-T

NPN LED 898D-N58PT-T

Device patchcords (straight to straight) 889D-F4ACDM-x(1)

(1) Replace x with 1 [1 m (3.28 ft)], 2 [2 m (6.56 ft)], 3 [3 m (9.84 ft)], 5 [5 m (16.40 ft)], or 10 [10 m (32.81 ft)] for standard cable lengths.

5

4 3

1

2 15 7 13 5 11 3 4 12 6 14 8 16

9 1 19 17 21 18 20 2 10

Rockwell Automation Publication 898-TD001B-EN-P - June 2019 5

Page 6: Distribution Boxes Tech Data - Rockwell Automation · 2019-07-24 · Port 1 Pin 4 Port 1 Pin 4 1 Port 2 Pin 4 Port 2 Pin 4 2 Port 3 Pin 4 Port 3 Pin 4 3 Port 4 Pin 4 Port 4 Pin 4

Distribution Boxes

Four-Pin, One or Two Signals per Port Cable with M23 Main Connector Distribution Box

Figure 7 - Approximate Dimensions

Figure 8 - Typical Wiring Diagram(s)

Table 13 - Specifications

Certifications UL recognized and CSA certified

MechanicalMaterial Gray Pocan

Connector insert material PBT

Receptacle shell material Zinc diecast with nickel plating

Contact material Gold-plated palladium/nickel

Main connector style 12- and 19- pin M23

EnvironmentalEnclosure type rating IP67, 1200 psi (8270 kPa) washdown

Operating temperature -20…+90 °C (-4…+194 °F)

Eight-port DC Micro Distribution Box

73 (2.87)107 (4.21)

4.5(0.18)

5.0 (0.20)

ALLEN

-BRAD

LEY

16.5 (0.65)

898D

-54P

T-M

12 B

19.7(0.78)

M23

3 (0.12)

29.2(0.15)

33(1.30)

39(1.54)

60(2.36)60

(2.36)

102 (4.02) 4-port

127 (5.0) 6-port

152 (5.98) 8-port

ALLE

N-BR

ADLE

Y

Dimensions are shown in mm (in.). Illustrations are not drawn to scale.Dimensions shown are not intended to be used for installation purposes.

Table 14 - Mating Components and Accessories

Description Cat. No.(3)

(3) Replace x with 1 [1 m (3.28 ft)], 2 [2 m (6.56 ft)], 3 [3 m (9.84 ft)], 5 [5 m (16.40 ft)], or 10 [10 m (32.81 ft)] for standard cable lengths.

Device patchcords 889D-F4ACDM-x

Homerun patchcord (12-pin) 889M-R11RMMU-x

Homerun patchcord (19-pin) 889M-R19RMMU-x

V-cable (dual) 879D-F4ADM-2

Sealing caps(1)

(1) Two provided with box.

1485A-M12

Labels(2)

(2) One set provided with box.

1492-MS9X20

3

5

41

5

3

PNP1 2

14

5

3 41

PNP PNP3

4

5

31

5

31

4

PNP4 5

PNP

3

5

41

5

3

PNP6 7

14

5

31

4

8PNP PNP

(-)1012

(PE)11(+)

19(-)

2 3 4 5 6 7 84 Port 6 Port 8 Port

5

52

1

PNP

3 4

1

PNP

6 7 8

(PE)12

(+)11

(-)(-)10 9 1 2 3 4

2

3

51

4 PNP

PNP1

3

52

1

PNP4

PNP1

PNP1

2

3

51

PNP4

4 Port

1

51

3

1

11217316515619

4

51

3 4

2

12(PE)

51

51

3 4

3

3 4

4

51

5

3 4

5

3

6

15

15

134 4

7

3 4

8

2 2 2 2 2 2 2 2

PNPPNP PNP PNP PNP PNP PNP PNP

PNP PNP PNP PNP PNP PNP PNP PNP

181013914847

4 Port 6 Port 8 Port

6 Rockwell Automation Publication 898-TD001B-EN-P - June 2019

Page 7: Distribution Boxes Tech Data - Rockwell Automation · 2019-07-24 · Port 1 Pin 4 Port 1 Pin 4 1 Port 2 Pin 4 Port 2 Pin 4 2 Port 3 Pin 4 Port 3 Pin 4 3 Port 4 Pin 4 Port 4 Pin 4

Distribution Boxes

Table 15 - Pinout

Device Connection Main Connection

Ports (4-Pin Female)M23 Connector(12-Pin Male)

4-Port (Single Channel)

4-Port (Dual Channel)

8-Port (Single Channel)

Ground Ground Ground 12

(+) All Ports Pin 1 (+) All Ports Pin 2 (+) All Ports Pin 1 11

(-) All Ports Pin 3 (-) All Ports Pin 4 (-) All Ports Pin 3 10 and 9

Port 1 Pin 4 Port 1 Pin 4 Port 1 Pin 4 1

Port 2 Pin 4 Port 2 Pin 4 Port 2 Pin 4 2

Port 3Pin 4 Port 3 Pin 4 Port 3 Pin 4 3

Port 4 Pin 4 Port 4 Pin 4 Port 4 Pin 4 4

— Port 1 Pin 2 Port 5 Pin 4 5

— Port 2 Pin 2 Port 6 Pin 4 6

— Port 3 Pin 2 Port 7 Pin 4 7

— Port 4 Pin 2 Port 8 Pin 4 8

Table 16 - Product Selection

PortsNo. of

Signals per Port

Illumination Assembly Rating Cat. No.(1)

(1) Replace x with 1 [1 m (3.28 ft)], 2 [2 m (6.56 ft)], 3 [3 m (9.84 ft)], 5 [5 m (16.40 ft)], or 10 [10 m (32.81 ft)] for standard cable lengths.

4 Port

Single (1)

No LED

10…30V DC,2 A per channel/

10 A total

898D-54PT-M12

PNP LED 898D-P54PT-M12

8 PortNo LED 898D-58PT-M12

PNP LED 898D-P58PT-M12

4 Port

Dual (2)

No LED 898D-54DT-M12

PNP LED 898D-P54DT-M12

8 PortNo LED 898D-58DT-M19

PNP LED 898D-P58DT-M19

Device patchcords (straight to straight) 889D-F4ACDM-x

Homerun patchcord for 12-pin (right angle to straight) 889M-R11RMMU-x

Homerun patchcord for 19-pin (right angle to straight) 889M-R19RMMU-x

5

4 3

1

2

2

3

45

6

1

11

10

98

712

Table 17 - Pinout

Device Connection Main Connection

Ports (4-Pin Female) M23 Connector (19-Pin Male)

8-Port (Dual Channel) —

Ground 12

(+) All Ports Pin 1 19

(-) All Ports Pin 3 6

Port 1 Pin 4 15

Port 2 Pin 4 5

Port 3 Pin 4 16

Port 4 Pin 4 3

Port 5 Pin 4 17

Port 6 Pin 4 2

Port 7 Pin 4 11

Port 8 Pin 4 1

Port 1 Pin 2 7

Port 2 Pin 2 4

Port 3 Pin 2 8

Port 4 Pin 2 14

Port 5 Pin 2 9

Port 6 Pin 2 13

Port 7 Pin 2 10

Port 8 Pin 2 18

5

4 3

1

2 2

3

456

11110

9

87

12

1813

1416

1719

15

Rockwell Automation Publication 898-TD001B-EN-P - June 2019 7

Page 8: Distribution Boxes Tech Data - Rockwell Automation · 2019-07-24 · Port 1 Pin 4 Port 1 Pin 4 1 Port 2 Pin 4 Port 2 Pin 4 2 Port 3 Pin 4 Port 3 Pin 4 3 Port 4 Pin 4 Port 4 Pin 4

Distribution Boxes

Pico Style Distribution Boxes

Three-Pin, Cable Connector Distribution Box

Figure 9 - Approximate Dimensions

Figure 10 - Typical Wiring Diagrams

Table 18 - Specifications

Certifications UL recognized and CSA certified

MechanicalMaterial Gray Pocan

Connector insert material PBT

Receptacle shell material Nickel-plated brass

Contact material Gold-plated palladium/nickel

Cable typeOil-resistant black PUR/PVC jacket, (3) 18 AWG stranded copper, (4, 6, 8, 10 or 12) 22 AWG flex rated for 1 million cycles

Cable diameter

4-port: 6.4 mm (0.25 in.)6-port: 7.2 mm (0.28 in.)8-port: 7.4 mm (0.29 in.)10-port: 7.6 mm (0.30 in.)12-port: 9.8 mm (0.39 in.)

EnvironmentalEnclosure type rating IP67

Operating temperature -20…+80 °C (-4…+176 °F)

Table 19 -

No. of Ports L R B A

4 57 (2.2) 39 (1.5) 85 (3.3) 92. (3.6)

6 83 (3.3) 65 (2.6) 111 (4.4) 118 (4.6)

8 109 (4.3) 91 (3.6) 137 (5.4) 144 (5.7)

10 135 (5.3) 117 (4.6) 163 (6.4) 170 (6.7)

12 161 (6.3) 143 (5.6) 189 (7.4) 196 (7.7)

Eight-port Pico Distribution Box

412

34.8 (1.37)

12 1 10 4

24(0.95)

AL

4.2 (0.17) Ø

17 (0.67)

8(0.31) 4.5

(0.18)

3.5 (0.14)

20 (0.79)

3.2(0.13)

R

4.2(0.17) Ø

4.2(0.17)

17 (0.67)18.2 (0.72) B

13

A B ALLEN-BRADLEY 898P-34PT-B5

Table 20 - Mating Components and Accessories

Description Cat. No.

Device patchcords 889P-F3ABPM-x(3)

(3) Replace x with 1 [1 m (3.28 ft)], 2 [2 m (6.56 ft)], 3 [3 m (9.84 ft)], 5 [5 m (16.40 ft)], or 10 [10 m (32.81 ft)] for standard cable lengths.

Field attachable connectors 871A-TS3-PM

IDC field attachable connectors 889P-M3DC-H

Sealing caps(1)

(1) Two provided with box.

889A-PMCAP

Labels(2)

(2) One set provided with box.

1492-M5X10

4-Port 6-Port 8-Port 10-Port

12-Port

LED-

GN

3

4

Bu1

Bu2

31

Bu3

31 1

4 4

Bu4

3 1

Bu5

3 31

4 4 4

Bu8

Bu6

1 3

Bu7

1 3

4 4

Bu9

31

Bu10

31 1

4 4

BROW

N(+

)

BLUE

(-)

AW

HITE

AGR

EEN

AYE

LLOW

AGR

AY

A A

PINK

GRAY

/PIN

KA

RED

ARE

D/BL

UE

BROW

N/GR

EEN

WHI

TE/G

REEN

A A

Bu12

Bu11

3

4

1 3

4

1

YELL

OW/B

ROW

N

WHI

TE/Y

ELLO

WA A

BLUE

(-)

BROW

N(+

)

3 1

4

WHI

TE

4

3 1

4

3 1 3

4

1 13

4

3

4

1 3

4 4

31 1

A A A A A A A A

GREE

N

YELL

OW

PINK

RED

BLAC

K

VIOL

ET

LED-

GN

Bu1

Bu2

Bu3

Bu4

Bu5

Bu6

Bu7

Bu8

4

313

Bu9

4

1

Bu10

A

GRAY

/PIN

KA

RED/

BLUE

GRAY

8 Rockwell Automation Publication 898-TD001B-EN-P - June 2019

Page 9: Distribution Boxes Tech Data - Rockwell Automation · 2019-07-24 · Port 1 Pin 4 Port 1 Pin 4 1 Port 2 Pin 4 Port 2 Pin 4 2 Port 3 Pin 4 Port 3 Pin 4 3 Port 4 Pin 4 Port 4 Pin 4

Distribution Boxes

Table 21 - Pinout

Device Connection Main Connection

Ports (3-Pin Female) Cable

4-Port 6-Port 8-Port 10-Port 12-Port —

Ground Ground Ground Ground Ground Green/Yellow

(+) All Ports Pin 1 (+) All Ports Pin 1 (+) All Ports Pin 1 (+) All Ports Pin 1 (+) All Ports Pin 1 Brown

(-) All Ports Pin 3 (-) All Ports Pin 3 (-) All Ports Pin 3 (-) All Ports Pin 3 (-) All Ports Pin 3 Blue

Port 1 Pin 4 Port 1 Pin 4 Port 1 Pin 4 Port 1 Pin 4 Port 1 Pin 4 White

Port 2 Pin 4 Port 2 Pin 4 Port 2 Pin 4 Port 2 Pin 4 Port 2 Pin 4 Green

Port 3 Pin 4 Port 3 Pin 4 Port 3 Pin 4 Port 3 Pin 4 Port 3 Pin 4 Yellow

Port 4 Pin 4 Port 4 Pin 4 Port 4 Pin 4 Port 4 Pin 4 Port 4 Pin 4 Gray

— Port 5 Pin 4 Port 5 Pin 4 Port 5 Pin 4 Port 5 Pin 4 Rose

— Port 6 Pin 4 Port 6 Pin 4 Port 6 Pin 4 Port 6 Pin 4 Red

— — Port 7 Pin 4 Port 7 Pin 4 — Black

— — Port 8 Pin 4 Port 8 Pin 4 — Violet

— — — Port 9 Pin 4 Port 7 Pin 4 Gray/Pink

— — — Port 10 Pin 4 Port 8 Pin 4 Red/Blue

— — — — Port 9 Pin 4 White/Green

— — — — Port 10 Pin 4 Brown/Green

— — — — Port 11 Pin 4 White/Yellow

— — — — Port 12 Pin 4 Yellow/Brown

3 1

4

Table 22 - Product Selection

Ports Illumination Assembly Rating Cat. No.(1)

(1) Replace x with 5 [5 m (16.40 ft)] or 10 [10 m (32.81 ft)] for standard cable lengths.

4 Port

PNP LED 10…30V DC,2 A per channel/ 6 A total

898P-P34PT-Bx

6 Port 898P-P36PT-Bx

8 Port 898P-P38PT-Bx

10 Port 898P-P310PT-Bx

12 Port 898P-P312PT-Bx

Device patchcords (3-pin straight to straight) 889P-F3ABPM-y(2)

(2) Replace y with 1 [1 m (3.28 ft)], 2 [2 m (6.56 ft)], 3 [3 m (9.84 ft)], 5 [5 m (16.40 ft)], or 10 [10 m (32.81 ft)] for standard cable lengths.

Rockwell Automation Publication 898-TD001B-EN-P - June 2019 9

Page 10: Distribution Boxes Tech Data - Rockwell Automation · 2019-07-24 · Port 1 Pin 4 Port 1 Pin 4 1 Port 2 Pin 4 Port 2 Pin 4 2 Port 3 Pin 4 Port 3 Pin 4 3 Port 4 Pin 4 Port 4 Pin 4

Distribution Boxes

Three-Pin, DC Micro Main Connector Distribution Box

Figure 11 - Approximate Dimensions

Figure 12 - Typical Wiring Diagram(s)

Table 23 - Specifications

Certifications UL recognized and CSA certified

MechanicalMaterial Gray Pocan

Connector insert material PBT

Receptacle shell material Nickel-plated brass

Contact material Gold-plated palladium/nickel

Main connector style 8-pin DC micro

EnvironmentalEnclosure type rating IP67

Operating temperature -20…+80 °C (-4…+176 °F)

No. of Ports L R B A

4 57 (2.2) 39 (1.5) 80 (3.1) 87 (3.4)

6 83 (3.3) 65 (2.6) 106 (4.2) 113 (4.4)

Table 24 - Product Selection

Ports Illumination Assembly Rating Cat. No.

4 PortPNP LED 10…30V DC,

2 A per channel/ 3 A total898P-P34PT-D8

6 Port 898P-P36PT-D8

Device patchcords (3-pin straight to straight) 889P-F3ABPM-x(1)

(1) Replace x with 1 [1 m (3.28 ft)], 2 [2 m (6.56 ft)], 3 [3 m (9.84 ft)], 5 [5 m (16.40 ft)], or 10 [10 m (32.81 ft)] for standard cable lengths.

Homerun patchcord for D8 models (right angle to straight) 889D-R8ABDM-x(1)

Six-port Pico Distribution Box

17(0.67)

3.2(0.13)

4.2(0.17)

4.2 (0.17) Ø11 (0.43)

9 (0.35)

3.5 (0.14)

R

18.2(0.72)

B

3.5 (0.14)

23(0.91)

AL

3.5 (0.14)

17(0.67)

24(0.95)

39.8 (1.17)

A B A B A B A B A B A B

41 3A B

ALLEN-BRADLEY 898P-P34PT-D8

Table 25 - Mating Components and Accessories

Description Cat. No.

Device patchcords (3-pin) 889P-F3ABPM-x(3)

(3) Replace x with 1 [1 m (3.28 ft)], 2 [2 m (6.56 ft)], 3 [3 m (9.84 ft)], 5 [5 m (16.40 ft)], or 10 [10 m (32.81 ft)] for standard cable lengths.

DC micro homerun patchcord 889D-R8ABDM-x(3)

Field attachable connectors 871A-TS3-PM

IDC field attachable connectors 889P-M3DC-H

Sealing caps(1)

(1) Two provided with box.

889A-PMCAP

Labels(2)

(2) One set provided with box.

1492-M5X10

Table 26 - Pinout

Device Connection Main Connection

Ports (3-Pin Female) 8-Pin DC Micro

4-Port 6-Port —

(+) All Ports Pin 1 (+) All Ports Pin 1 7

(-) All Ports Pin 3 (-) All Ports Pin 3 5

Port 1 Pin 4 Port 1 Pin 4 1

Port 2 Pin 4 Port 2 Pin 4 2

Port 3 Pin 4 Port 3 Pin 4 3

Port 4 Pin 4 Port 4 Pin 4 4

— Port 5 Pin 4 6

— Port 6 Pin 4 8

5(-)

7(+

)

3 1

4

4

4 Channel

6 Channel

4

3 1

4

3 1 3

4

1 13

4

3

4

1

321 6 8

LED-

GN

Bu1

Bu2

Bu3

Bu4

Bu5

Bu6

LED-

A

LED-

A

LED-

A

LED-

A

LED-

A

LED-

A

3 1

4

5-Aux A 6-Aux A7

8

4

3-GND1-Safety A

2-Safety A

10 Rockwell Automation Publication 898-TD001B-EN-P - June 2019

Page 11: Distribution Boxes Tech Data - Rockwell Automation · 2019-07-24 · Port 1 Pin 4 Port 1 Pin 4 1 Port 2 Pin 4 Port 2 Pin 4 2 Port 3 Pin 4 Port 3 Pin 4 3 Port 4 Pin 4 Port 4 Pin 4

Distribution Boxes

IDC Style Distribution Boxes

One Signal per Port Cable Connector Distribution Box

Figure 13 - Approximate Dimensions

Figure 14 - Typical Wiring Diagram

Table 27 - Specifications

Certifications UL recognized and CSA certified

MechanicalMaterial Gray Pocan

Connector insert material PBT

Receptacle shell material Nickel-plated brass

Contact material Gold-plated palladium/nickel

IDC installations, max 10

Cable type Oil-resistant black PUR/PVC jacket, (3) 18 AWG stranded copper, (8 or 16) 22 AWG flex rated for 1 million cycles

Cable diameter 7.4 mm (0.29 in.)

Conductor OD 24…22 AWG, 1.6…2.0 mm (0.063…0.079 in.)

EnvironmentalEnclosure type rating IP67, 1200 psi (8270 kPa) washdown

Operating temperature -20…+90 °C (-4…+194 °F)

Table 28 - Product Selection

Ports Illumination Assembly Rating Cat. No.

8 PortNo LED 10…30V DC,

2 A per channel/ 10 A total

898H-58PT-Bx(1)

(1) Replace x with 5 [5 m (16.40 ft)] or 10 [10 m (32.81 ft)] for standard cable lengths.

PNP LED 898H-P58PT-Bx(1)

Device patchcords (3-pin straight to straight) 889A-HCC3

Device patchcords (3-pin straight to straight) 889D-F4AC-y(2)

(2) Replace y with 2 [2 m (6.56 ft)], 5 [5 m (16.40 ft)] or 10 [10 m (32.81 ft)] for standard cable lengths.

Eight-port IDC Style Distribution Box

IDC Insert

60(2.36)

39(1.54)

25(0.98)

898H

-58PT-

B5 B

Allen

Brad

ley 1 231

2 3 12 3

31 2

12 3

31 2

12 3

31 2

152(5.98) 8 port

107 (4.21)73 (2.87)

4.5(0.18)

13.5(0.53)

33(1.3)

13.5 (0.53)

16.5 (0.65)

18 (0.71)

5.0(0.2)

Dimensions are shown in mm (in.). Illustrations are not drawn to scale.Dimensions shown are not intended to be used for installation purposes.

Table 29 - Mating Components and Accessories

Description Cat. No.

Device patchcords 889D-F4AC-x(3)

(3) Replace x with 2 [2 m (6.56 ft)], 5 [5 m (16.40 ft)], or 10 [10 m (32.81 ft)] for standard cable lengths.

Three-pole IDC insert (required for connection with IDC box)

889A-HCC3

Sealing caps(1)

(1) Two provided with box.

1485A-M12

Labels(2)

(2) One set provided with box.

1492-MS9X20

Table 30 - Pinout

Device Connection Main Connection

Ports (IDC) Cable Connector

8-Port —

(+) All Ports Pin 1 Brown

(-) All Ports Pin 3 Blue

Port 1 Pin 2 White

Port 2 Pin 2 Green

Port 3 Pin 2 Yellow

Port 4 Pin 2 Gray

Port 5 Pin 2 Rose

Port 6 Pin 2 Red

Port 7 Pin 2 Black

Port 8 Pin 2 Violet

4-Port

(+)B

rown

(-)Bl

ue

Whi

te

Gree

n

Yello

w

Grey

Pink

Red

6-Port 8-Port

3

12

1111

3

2

33

22

3

221

21

3 3

21

3

1 2 3 4 5 6 7 8

Blac

k

Viole

t

Wiring diagram shows PNP wiring. Actual units use PNP LED or no LED.

1

3

2

Rockwell Automation Publication 898-TD001B-EN-P - June 2019 11

Page 12: Distribution Boxes Tech Data - Rockwell Automation · 2019-07-24 · Port 1 Pin 4 Port 1 Pin 4 1 Port 2 Pin 4 Port 2 Pin 4 2 Port 3 Pin 4 Port 3 Pin 4 3 Port 4 Pin 4 Port 4 Pin 4

Allen-Bradley, Rockwell Software, Rockwell Automation, and LISTEN. THINK. SOLVE are trademarks of Rockwell Automation, Inc.Trademarks not belonging to Rockwell Automation are property of their respective companies.

Publication 898-TD001B-EN-P - June 2019

Rockwell Automation SupportUse the following resources to access support information.

Documentation FeedbackYour comments will help us serve your documentation needs better. If you have any suggestions on how to improve this document, complete the How Are We Doing? form at http://literature.rockwellautomation.com/idc/groups/literature/documents/du/ra-du002_-en-e.pdf.

Technical Support Center Knowledgebase Articles, How-to Videos, FAQs, Chat, User Forums, and Product Notification Updates. www.rockwellautomation.com/knowledgebase

Local Technical Support Phone Numbers Locate the phone number for your country. www.rockwellautomation.com/global/support/get-support-now.page

Direct Dial CodesFind the Direct Dial Code for your product. Use the code to route your call directly to a technical support engineer.

www.rockwellautomation.com/global/support/direct-dial.page

Literature Library Installation Instructions, Manuals, Brochures, and Technical Data. www.rockwellautomation.com/literature

Product Compatibility and Download Center (PCDC)

Get help determining how products interact, check features and capabilities, and find associated firmware.

www.rockwellautomation.com/global/support/pcdc.page

Rockwell Otomasyon Ticaret A.Ş., Kar Plaza İş Merkezi E Blok Kat:6 34752 İçerenköy, İstanbul, Tel: +90 (216) 5698400

Rockwell Automation maintains current product environmental information on its website at http://www.rockwellautomation.com/rockwellautomation/about-us/sustainability-ethics/product-environmental-compliance.page.

Waste Electrical and Electronic Equipment (WEEE)

At the end of life, this equipment should be collected separately from any unsorted municipal waste.

Supersedes Publication 898-TD001A-EN-P - April 2016 Copyright © 2019 Rockwell Automation, Inc. All rights reserved. Printed in the U.S.A.


Recommended