+ All Categories
Home > Documents > Disturbance recording - ABB Ltd · disturbance recording solution, with 10 kHz sampling and the ......

Disturbance recording - ABB Ltd · disturbance recording solution, with 10 kHz sampling and the ......

Date post: 09-Jun-2018
Category:
Upload: leliem
View: 230 times
Download: 0 times
Share this document with a friend
2
FACTSHEET Disturbance recording 6000 series DRL6600U version 8.30 DRL6600U offers an extendable disturbance recording solution, with 10 kHz sampling and the ability to monitor and record GOOSE communication on the station or process bus. It can record up to 96 analog input channels and 192 binary input channels and more as 5000 disturbance recordings can be stored simultaneously. Scalable solution for: • 32 analog inputs (24I, 8U) and 8 DC inputs • 48 analog inputs (32I, 16U) • 64 analog inputs (32I, 32U) • 80 analog inputs (40I, 40U) • 96 analog inputs (56I, 40U) Functionality • Signal indication • Event recording • Disturbance reporting - Short form report giving a brief overview on an event or recording • Disturbance recording - Pre-trigger: 0 ~ 25 cycles, 1 – 10 kHz - Trigger: 0 ~ 50 cycles, 1 – 10 kHz - Post trigger: 150 cycles, 0.5 – 10 kHz • Waveform analysis - Sequence and period components - Power calculation - Harmonics calculation - Ranging • Fault location Triggering functions • Phase overcurrent, overvoltage and undervoltage • Positive sequence overvoltage and undervoltage • Negative sequence overcurrent and overvoltage • Zero sequence (residual) overcurrent, overvoltage • Sudden change phase current and voltage, • Sudden change zero sequence (residual) current and voltage • Current variation • Over, under and rate of change of frequency • Third harmonic overvoltage • Fifth harmonic overvoltage • Seventh harmonic overvoltage • Binary signal triggering Secondary system supervision • Voltage circuit supervision • Current circuit supervision The DRL6600U consists of a recording IED and a HMI front end
Transcript
Page 1: Disturbance recording - ABB Ltd · disturbance recording solution, with 10 kHz sampling and the ... It can record up to 96 analog input channels and 192 binary input channels and

— FAC TS H EE T

Disturbance recording6000 series DRL6600U version 8.30

DRL6600U offers an extendable disturbance recording solution, with 10 kHz sampling and the ability to monitor and record GOOSE communication on the station or process bus. It can record up to 96 analog input channels and 192 binary input channels and more as 5000 disturbance recordings can be stored simultaneously.

Scalable solution for:• 32 analog inputs (24I, 8U) and 8 DC inputs• 48 analog inputs (32I, 16U)• 64 analog inputs (32I, 32U)• 80 analog inputs (40I, 40U) • 96 analog inputs (56I, 40U)

Functionality• Signal indication• Event recording• Disturbance reporting

- Short form report giving a brief overview on an event or recording

• Disturbance recording - Pre-trigger: 0 ~ 25 cycles, 1 – 10 kHz - Trigger: 0 ~ 50 cycles, 1 – 10 kHz - Post trigger: 150 cycles, 0.5 – 10 kHz

• Waveform analysis - Sequence and period components - Power calculation - Harmonics calculation - Ranging

• Fault location

Triggering functions• Phase overcurrent, overvoltage and undervoltage• Positive sequence overvoltage and undervoltage• Negative sequence overcurrent and overvoltage• Zero sequence (residual) overcurrent, overvoltage• Sudden change phase current and voltage,• Sudden change zero sequence (residual) current

and voltage• Current variation• Over, under and rate of change of frequency• Third harmonic overvoltage• Fifth harmonic overvoltage• Seventh harmonic overvoltage• Binary signal triggering

Secondary system supervision• Voltage circuit supervision• Current circuit supervision

—The DRL6600U consists of a recording IED and a HMI front end

Page 2: Disturbance recording - ABB Ltd · disturbance recording solution, with 10 kHz sampling and the ... It can record up to 96 analog input channels and 192 binary input channels and

4C

AE

00

036

2 R

evA

—We reserve the right to make technical changes or modify the contents of this document without prior notice. With regard to purchase orders, the agreed particulars shall prevail. ABB AB does not accept any responsibility whatsoever for potential errors or possible lack of information in this document.

We reserve all rights in this document and in the subject matter and illustrations contained therein. Any reproduction, disclosure to third parties or utilization of its contents – in whole or in parts – is forbidden without prior written consent of ABB AB. Copyright© 2017 ABBAll rights reserved

—ABB ABSubstation Automation Products721 59 Västerås, SwedenPhone: +46 (0) 21 32 50 00

abb.com/protection-control

Security, engineering, testing, commissioning, and maintenance• Authority management• AE600 – Fault recording analysis software• MCU – DRL6600U configuration software

Hardware• 1/1 x 19”, 12U height case

- IED front panel IP 40 - HMI front panel and side IP 40 - HMI and IED back panel, connecting terminal

IP 20• Power supply modules for 110 and 220 VDC• Up to 96 analog inputs

- Nominal current 1 A or 5 A - Nominal voltage 300 VAC - Sampling rate: up to 10 kHz

• 192 binary inputs - Maximum input voltage 300VDC - Compression type connectors

• DC inputs - 0…10 V, 0…300 V, 4…20 mA

• Accurate time-synchronization through SNTP, IRIG-B or PPS/PPM

• Supports highest EMC requirements. Technical details are available in the Product Guide.

• Independent laboratory certified

Communication

Service portTo IED, LAN1, TCP/IP, RJ45

IED to LHMI, RJ45

IEC 61850-8-1

MMS DRL6600U-HMI, 6 ports, RJ45, 100BASE-FX

GOOSE DRL6600U, 1 port, RJ45, 100BASE-FX

Environmental

Operation temperature range -10 ... +55 oC continuous)

Short-time service temperature range -25…+70 oC (<16 h)

Relative humidity <93 %, no moisture condensation

Altitude Maximum 2000 m

Transport and storage temperature range -40...+70 oC


Recommended