8Sep 2003Run2b Readout Meeting
Qun Yu / Moreshwar DholeLouisiana Tech University
DJC Testing at LaTech:Update
8Sep 2003Run2b Readout Meeting
Qun Yu / Moreshwar DholeLouisiana Tech University
Quality Control Tests of DJC’s1. Continuity and shorts test2. Resistance testing3. High voltage standoff testing.
LaTech Testing Crew:Moreshwar DholeQun YuMatthew BellotHenry Hollins
8Sep 2003Run2b Readout Meeting
Qun Yu / Moreshwar DholeLouisiana Tech University
Since our last report• Updated and improved our database
to reflect changes suggested last time and to include results of recent testing
• Received 168 50cm-test cables from Century– Commenced affixing backings to cables
as per procedure from Jim Fast– In parallel, ~80 of these have been
tested
8Sep 2003Run2b Readout Meeting
Qun Yu / Moreshwar DholeLouisiana Tech University
On the following slide are sample data from SHEET 1 of the DJC database (http://caps.phys.latech.edu/~greenw/run2b/run2b_page.html)
8Sep 2003Run2b Readout Meeting
Qun Yu / Moreshwar DholeLouisiana Tech University
ID Type Vendor Location Length_cm Tested Resistence Tester Date TestedCurrent Shorts-Open < 3 σ
CT 150 Test Century FermilabCT 151 Test Century LTU 50 Tested OK Yes Moreshwar 7/30/2003CT 152 Test Century Fermilab 50 Tested OK Yes Moreshwar 7/29/2003CT 153 Test Century Fermilab 50 Tested OK Yes Moreshwar 7/29/2003CT 154 Test Century LTU 50 Tested OK Yes Moreshwar 7/30/2003CT 155 Test Century LTU 50 Tested OK Yes Moreshwar 7/30/2003CT 156 Test Century LTU 50 Tested OK Yes Moreshwar 7/30/2003CT 157 Test Century LTU 50 Tested OK Yes Moreshwar 7/30/2003CT 158 Test Century LTU 50 Tested OK Yes Moreshwar 7/30/2003CT 159 Test Century LTU 50 Tested OK Yes Moreshwar 7/30/2003CT 160 Test Century Fermilab 50 Tested OK Yes Moreshwar 7/29/2003
8Sep 2003Run2b Readout Meeting
Qun Yu / Moreshwar DholeLouisiana Tech University
• Also on the DJC database spreadsheet is SHEET 2 which has resistance measurements, mean resistances and standard deviations. Part of this sheet is on the next slide..
8Sep 2003Run2b Readout Meeting
Qun Yu / Moreshwar DholeLouisiana Tech University
Line Line Board Resistance Resistance MEAN STANDARDNumber Description Resistance cable ct_19 cable ct_21 RESISTANCE DEVIATION
(CENTURY) (CENTURY)35 AVDD(S) 0.094 2.883 2.646 2.529 0.22837 AVDD 0.096 0.19 0.161 0.163 0.01839 AVDD 0.099 0.185 0.157 0.157 0.01241 GND 0.099 0.092 0.082 0.084 0.01543 DVDD(S) 0.098 2.932 2.726 2.614 0.25045 DVDD 0.102 0.183 0.143 0.146 0.01447 DVDD 0.105 0.18 0.144 0.150 0.022
8Sep 2003Run2b Readout Meeting
Qun Yu / Moreshwar DholeLouisiana Tech University
Some Observations…• We have tested ~125 Century
cables.• Of these, ~ 10 cables have some
type of defect- shorts between lines, discontinuity, or high resistance. Shorts are the most common of these.
8Sep 2003Run2b Readout Meeting
Qun Yu / Moreshwar DholeLouisiana Tech University
• END OF REPORT
8Sep 2003Run2b Readout Meeting
Qun Yu / Moreshwar DholeLouisiana Tech University
• EXTRA SLIDES
8Sep 2003Run2b Readout Meeting
Qun Yu / Moreshwar DholeLouisiana Tech University
Digital Jumper Cable Readout Setup:
8Sep 2003Run2b Readout Meeting
Qun Yu / Moreshwar DholeLouisiana Tech University
3) High Voltage Standoff Test: • The purpose of this test is to check
whether there is any short or current leakage (Arcing) between HV (High Voltage) Cu trace and other adjacent Cu traces.
• For this testing here at LaTech we developed our own High Voltage Testing Jig and it is working fine.
• This High Voltage Testing Jig allows us to test 10 cables at a time for overnight.
8Sep 2003Run2b Readout Meeting
Qun Yu / Moreshwar DholeLouisiana Tech University
Test procedure: • Continuity: two multimeter probes
are connected to both ends of the line in a given cable, if the line is good, there will be “beep” from multimeter.
• Short circuit tests: each line is tested against its nearest neighbor.
8Sep 2003Run2b Readout Meeting
Qun Yu / Moreshwar DholeLouisiana Tech University
High Voltage Test Schematic
8Sep 2003Run2b Readout Meeting
Qun Yu / Moreshwar DholeLouisiana Tech University
Complete Test Setup: