DM : Validation Class Absolute tolerance Limit DM : Validation Class Absolute tolerance Limit Presented By : Rakesh Dasgupta Presented By : Rakesh Dasgupta Content at : http://wp.me/p1Ci5j Content at : http://wp.me/p1Ci5j-1p 1p
Transcript

DM : Validation Class – Absolute tolerance LimitDM : Validation Class – Absolute tolerance Limit

Presented By : Rakesh DasguptaPresented By : Rakesh Dasgupta

Content at : http://wp.me/p1Ci5jContent at : http://wp.me/p1Ci5j--1p1p

AgendaAgenda

1.Validations in Device Management

2.Tolerance Limits

3.Demo

4.Questions .

Validations in Device Management IValidations in Device Management I

In the SAP system we have Validations for the Meter Reading Results.

There are 2 types of Validations.

1. Independent Validations.

2. Dependent Validations.

Menu path in customizing is Device Management -> Meter Reading -> Validations.

We also have User defined Validations.Menu path in customizing is Tools -> System Modifications -> User Defined

Validations.Validations.

Independent ValidationsIndependent Validations

•Validation that applies to one specific register.

•Fixed independent validations are carried out automatically in the system.

•Variable independent validations are carried out based on customizing settings.

Fixed Independent Validations Fixed Independent Validations are

•95 (previous meter reading implausible)

•96 (fixed value deviation validation)

•97 (resetting register validation)

Variable Independent Validations areVariable Independent Validations are•01 (zero consumption)

•02 - 04 (permitted number of meter readings by the customer, estimations

and estimations + meter readings by the customer)

•05-07 (tolerance limits, absolute, relative and floating)

•11 (usage hours greater than usage hours of previous period)

•12 (usage hours compared to fixed value)

•13 (current demand compared to maximum demand)

Validations in Device Management IIValidations in Device Management II

•13 (current demand compared to maximum demand)

•14 (current demand compared with minimum demand)

•15 (meter overflow)

Dependent Validations

Validation that applies to several registers in one device or

installation

Validations :

•Active/reactive relationship 01

•Serial switching relationship 02

•On-/off peak relationship 03

Validations in Device Management IIIValidations in Device Management III

•On-/off peak relationship 03

•Control relationship 04

•Volume correction factor relationship 05

•Volume correction factor calculation relationship 06

•Resetting register relationship 07

For more info on Validations check out the Customizing path in the SAP system

Period Consumption : 300 units for 30 daysPeriod Consumption : 300 units for 30 days

Independent Validation Allotted : Independent Validation Allotted : 05 Tolerance Limit Absolute05 Tolerance Limit Absolute

Comparison Period for 0001 defined as 1.Comparison Period for 0001 defined as 1.(1 month comparison)(1 month comparison)

Tolerance Limits of Independent ValidationsTolerance Limits of Independent Validations

For consumption 0 to 399

1. Warning displayed

+dev 20 units and –dev 20 units+dev 20 units and –dev 20 units

2. Error displayed

+dev 30 units and -30 units

For Consumption 400 to ….

1. Warning displayed

+dev 20 units and –dev 20 units

2. Error displayed

+dev 30 units and -30 units

Estimated MR on 24012011 Estimated MR on 24012011

MR given as 260 : NO Error/WarningMR given as 260 : NO Error/Warning

MR Given as 205 units : Error given MR Given as 205 units : Error given --DeviationDeviation

MR given as 270 units : Warning +deviation MR given as 270 units : Warning +deviation

MR Given as 280 units : Error +deviationMR Given as 280 units : Error +deviation

Meter Reading for Feb. Estimated ReadingMeter Reading for Feb. Estimated Reading

MR given as 545 units : Error MR given as 545 units : Error --DeviationDeviation

Goes to Implausible ReadingGoes to Implausible Reading

DemoDemo

QuestionsQuestions