  • 8/13/2019 DMS 2 Thickness Gauge Training

    1/34

    DMS 2

    Versatile, easy to use A-Scan thickness

    gauge loaded with time saving features.

  • 8/13/2019 DMS 2 Thickness Gauge Training

    2/34

    GEIT Proprietary Information -

    Subject to restrictions on the cover or first page.2

    TG MODE

    When unit is turned on, it

    goes to the TG ModeConfirms probe andmeasurement modes in one

    view.

  • 8/13/2019 DMS 2 Thickness Gauge Training

    3/34

    GEIT Proprietary Information -

    Subject to restrictions on the cover or first page.3

    Probe Selection - Dialog Probe

    Dialog Probe : Automatically

    selected by the instrument.Can not change selection.

    Sets up Gain, Gates, Mode

    and other probe selectionitems.

  • 8/13/2019 DMS 2 Thickness Gauge Training

    4/34

    GEIT Proprietary Information -

    Subject to restrictions on the cover or first page.4

    Probe Selection - Non-Dialog Probe

    User selects probe from list

    of probes available in theinstrument.

    Scroll the probe soft-key toreview all the probes in theprobe list.

    KBA560

    KBA525

    KBA550

    HT400A

    HT400

    FH2E

    DP104

    DA317

    DA312

    DA312B

    DA305

    + Others

  • 8/13/2019 DMS 2 Thickness Gauge Training

    5/34

    GEIT Proprietary Information -

    Subject to restrictions on the cover or first page.5

    Measurement Mode

    Select Measurement Mode

    for application

    Non-Coated Material =DUAL

    Coated Material = DUAL-MULTI

  • 8/13/2019 DMS 2 Thickness Gauge Training

    6/34

    GEIT Proprietary Information -

    Subject to restrictions on the cover or first page.6

    DUAL Mode

    Measurement is made to

    the 1st backwall echo.

    Used for makingmeasurements when nocoatings are present on thetest object

    Carrot shows echo

    being measured

  • 8/13/2019 DMS 2 Thickness Gauge Training

    7/34

    GEIT Proprietary Information -

    Subject to restrictions on the cover or first page.7

    DUAL-MULTI Mode

    Measurement is made from

    the 1st backwall echo to the2nd backwall echo

    Requires 2 gate operation.

    Used for measuringmaterials with coatings areon the surface

    Carrots shows echoes

    being measured

  • 8/13/2019 DMS 2 Thickness Gauge Training

    8/34

    GEIT Proprietary Information -

    Subject to restrictions on the cover or first page.8

    Probe Zero Mode

    Probe zero measures thedelay times in the probe so

    the instrument knows whento start measuring the testmaterial.

    AUTO - automatically setszero (default)

    MANUAL - User has topress PRB ZERO key tozero the probe.

  • 8/13/2019 DMS 2 Thickness Gauge Training

    9/34

    GEIT Proprietary Information -

    Subject to restrictions on the cover or first page.9

    Thickness Calibration Options - 1 Point

    Calibrate to a known

    thickness sample or cal.Block

    DMS 2 performs Zero

    Couple to sample

    Adjust thickness and press

    SEND

  • 8/13/2019 DMS 2 Thickness Gauge Training

    10/34

    GEIT Proprietary Information -

    Subject to restrictions on the cover or first page.10

    Thickness Calibration Options - 2 Point

    Calibration on a Thin andThick calibration Block

    Set THKCAL to 2-PT

    Adjust Low BlockThickness

    Measure and press SEND

    Adjust High Block

    Thickness

    Measure and press SEND

  • 8/13/2019 DMS 2 Thickness Gauge Training

    11/34

    GEIT Proprietary Information -

    Subject to restrictions on the cover or first page.11

    2 Point Calib. Memory

    DMS 2 remembers thethin

    andthick

    values so youDONTadjust them everytime you calibrate

    Simply press CAL, and theSEND key twice tocomplete a 2-pt Calibration

    Remembered

    Values

  • 8/13/2019 DMS 2 Thickness Gauge Training

    12/34

    GEIT Proprietary Information -

    Subject to restrictions on the cover or first page.12

    Velocity Calibration

    Adjust velocity to knowvalue to calibrate system

  • 8/13/2019 DMS 2 Thickness Gauge Training

    13/34

    GEIT Proprietary Information -

    Subject to restrictions on the cover or first page.13

    Alarm Menu

    Set and turn on both Min.

    and Max. alarmsIf thickness values exceedthe limits, the red LED will

    light, < or > icon shows thealarm on the display.

  • 8/13/2019 DMS 2 Thickness Gauge Training

    14/34

    GEIT Proprietary Information -

    Subject to restrictions on the cover or first page.14

    A-Gate Menu

    Adjust and set

    measurement gate settingsStart position

    Height

    Width

    Also, adjust probe delay

  • 8/13/2019 DMS 2 Thickness Gauge Training

    15/34

    GEIT Proprietary Information -

    Subject to restrictions on the cover or first page.15

    B-Gate Menu (only when in Dual-Multi Mode)

    Adjust and set

    measurement gate settingsStart position

    Height

    Width

  • 8/13/2019 DMS 2 Thickness Gauge Training

    16/34

    GEIT Proprietary Information -

    Subject to restrictions on the cover or first page.16

    B-Scan Operation

    Before Starting B-Scan

    Set Range

    Set Sweep Time

    Set Time-Out

    Set T-Min. Value (same asalarm T-Min.)

  • 8/13/2019 DMS 2 Thickness Gauge Training

    17/34

    GEIT Proprietary Information -

    Subject to restrictions on the cover or first page.17

    B-Scan Operation

    During the scan

    Range, Time, T-Min itemsare not shown

    No thickness display isshown

  • 8/13/2019 DMS 2 Thickness Gauge Training

    18/34

    GEIT Proprietary Information -

    Subject to restrictions on the cover or first page.18

    B-Scan Operation

    At the end of the scan

    Minimum value isdisplayed

    Range, Time, T-Min valuesare shown (but notchangeable)

    CLEAR function is active -Pressing CLEAR will erasethe B-Scan and start the

    process over.

  • 8/13/2019 DMS 2 Thickness Gauge Training

    19/34

    GEIT Proprietary Information -

    Subject to restrictions on the cover or first page.19

    Parameter Sets

    ONLY the DMS 2 allows

    Parameter Sets to be savedfor both single AND dualelement probes.

    Complete calibrationincluding Velocity settings.

  • 8/13/2019 DMS 2 Thickness Gauge Training

    20/34

    GEIT Proprietary Information -

    Subject to restrictions on the cover or first page.20

    Parameter Sets

    Using parameter sets allows for saving and

    recalling special set-ups.Only a simple calibration check may be required

    after recalling a Parameter set. Significant timesaver!!!

  • 8/13/2019 DMS 2 Thickness Gauge Training

    21/34

    GEIT Proprietary Information -

    Subject to restrictions on the cover or first page.21

    TEST MODE

    TEST key always takes you

    to the TEST ModeActs like home key.

    Where MENU you are inpressing the TEST key willtake you out and to theTEST menu.

  • 8/13/2019 DMS 2 Thickness Gauge Training

    22/34

    GEIT Proprietary Information -

    Subject to restrictions on the cover or first page.22

    MIN-CAP saves time

    Use the DMS 2 Min-Cap mode to always get

    the minimum thickness.Fast 32Hz measurement rate.

    Time Out mode allows re-couple of probe tocomplete scanning (no need to start over).

  • 8/13/2019 DMS 2 Thickness Gauge Training

    23/34

    GEIT Proprietary Information -

    Subject to restrictions on the cover or first page.23

    Min Cap Mode

    While Scanning, the

    minimum value measured isdisplayed in the black box.

    The live value is in big digits

  • 8/13/2019 DMS 2 Thickness Gauge Training

    24/34

    GEIT Proprietary Information -

    Subject to restrictions on the cover or first page.24

    Time Out Bar

    If you un-couple during a

    Min-Cap scan, the time outbar indicated how muchtime is left that you can re-couple to continue the scan.

  • 8/13/2019 DMS 2 Thickness Gauge Training

    25/34

    GEIT Proprietary Information -

    Subject to restrictions on the cover or first page.25

    Min-Cap Completed

    When the time out has

    completed, the DMS 2 willdisplay the thinnest readingtaken during the scan anddisplay the associated A-Scan.

  • 8/13/2019 DMS 2 Thickness Gauge Training

    26/34

    GEIT Proprietary Information -

    Subject to restrictions on the cover or first page.26

    The BACK or Secondary Menus

    Press the LEFT and RIGHTarrow keys at the same time

    Secondary Menu System isDisplayed

  • 8/13/2019 DMS 2 Thickness Gauge Training

    27/34

    GEIT Proprietary Information -

    Subject to restrictions on the cover or first page.27

    Secondary Menu Items

    Set-Up Menu

    I/O Menu

    Display Menu

    Global Menu

    Operator Menu

  • 8/13/2019 DMS 2 Thickness Gauge Training

    28/34

    GEIT Proprietary Information -

    Subject to restrictions on the cover or first page.28

    Multiple Update Rates

    Only the DMS 2 enablesthe user to set the defaultupdate rate.

    > 4 Hz

    > 8 Hz> 12 Hz

    > 16 Hz

    > 32 Hz (B-Scan & Min-Cap Modes)

  • 8/13/2019 DMS 2 Thickness Gauge Training

    29/34

    GEIT Proprietary Information -

    Subject to restrictions on the cover or first page.29

    DMS 2 Scans FASTER

    32 Hz update rate in B-Scan and MIN-CAP modeallows users to scan faster.

    Higher frequency update

    rate = fast scanning withbetter coverage

    Approx. Speed of 2

    inches/second.

  • 8/13/2019 DMS 2 Thickness Gauge Training

    30/34

    TopCOAT IS a Superior

    Through CoatingMeasurement Technique

  • 8/13/2019 DMS 2 Thickness Gauge Training

    31/34

    GEIT Proprietary Information -

    Subject to restrictions on the cover or first page.31

    TopCOAT

    Superior Thru-Coating Thickness Measurement

    TC-560 4 Element Probe

    No need to calibrate to coating thickness

    Have Auto-Velocity Mode

    Temperature Limit (130 F)

    DMS 2 Coating Value Prominent

  • 8/13/2019 DMS 2 Thickness Gauge Training

    32/34

    GEIT Proprietary Information -

    Subject to restrictions on the cover or first page.32

    DMS 2 Coating Value - Prominent

    With no data logger fileactive, the CoatingThickness value is largeand very easy to read

    With data logger file active,small coating value is aboutthe same size as the 37DL+

    text but easier to read

  • 8/13/2019 DMS 2 Thickness Gauge Training

    33/34

    GEIT Proprietary Information -

    Subject to restrictions on the cover or first page.33

    Auto-V Mode

    No Material CalibrationNeeded

    No Special CalibrationBlocks

  • 8/13/2019 DMS 2 Thickness Gauge Training

    34/34

    GEIT Proprietary Information - 34

    Conclusion

    DMS 2 is the gauge with thebest value vs. features

    Works with a wider varietyof probes for solving

    corrosion applicationsHas the best utility Softwareavailable


Recommended