TG MODE
When unit is turned on, it
goes to the TG ModeConfirms probe andmeasurement modes in one
view.
8/13/2019 DMS 2 Thickness Gauge Training
3/34
GEIT Proprietary Information -
Subject to restrictions on the cover or first page.3
Probe Selection - Dialog Probe
Dialog Probe : Automatically
selected by the instrument.Can not change selection.
Sets up Gain, Gates, Mode
and other probe selectionitems.
8/13/2019 DMS 2 Thickness Gauge Training
4/34
GEIT Proprietary Information -
Subject to restrictions on the cover or first page.4
Probe Selection - Non-Dialog Probe
User selects probe from list
of probes available in theinstrument.
Scroll the probe soft-key toreview all the probes in theprobe list.
KBA560
KBA525
KBA550
HT400A
HT400
FH2E
DP104
DA317
DA312
DA312B
DA305
+ Others
8/13/2019 DMS 2 Thickness Gauge Training
5/34
GEIT Proprietary Information -
Subject to restrictions on the cover or first page.5
Measurement Mode
Select Measurement Mode
for application
Non-Coated Material =DUAL
Coated Material = DUAL-MULTI
8/13/2019 DMS 2 Thickness Gauge Training
6/34
GEIT Proprietary Information -
Subject to restrictions on the cover or first page.6
DUAL Mode
Measurement is made to
the 1st backwall echo.
Used for makingmeasurements when nocoatings are present on thetest object
Carrot shows echo
being measured
8/13/2019 DMS 2 Thickness Gauge Training
7/34
GEIT Proprietary Information -
Subject to restrictions on the cover or first page.7
DUAL-MULTI Mode
Measurement is made from
the 1st backwall echo to the2nd backwall echo
Requires 2 gate operation.
Used for measuringmaterials with coatings areon the surface
Carrots shows echoes
being measured
8/13/2019 DMS 2 Thickness Gauge Training
8/34
GEIT Proprietary Information -
Subject to restrictions on the cover or first page.8
Probe Zero Mode
Probe zero measures thedelay times in the probe so
the instrument knows whento start measuring the testmaterial.
AUTO - automatically setszero (default)
MANUAL - User has topress PRB ZERO key tozero the probe.
8/13/2019 DMS 2 Thickness Gauge Training
9/34
GEIT Proprietary Information -
Subject to restrictions on the cover or first page.9
Thickness Calibration Options - 1 Point
Calibrate to a known
thickness sample or cal.Block
DMS 2 performs Zero
Couple to sample
Adjust thickness and press
SEND
8/13/2019 DMS 2 Thickness Gauge Training
10/34
GEIT Proprietary Information -
Subject to restrictions on the cover or first page.10
Thickness Calibration Options - 2 Point
Calibration on a Thin andThick calibration Block
Set THKCAL to 2-PT
Adjust Low BlockThickness
Measure and press SEND
Adjust High Block
Thickness
Measure and press SEND
8/13/2019 DMS 2 Thickness Gauge Training
11/34
GEIT Proprietary Information -
Subject to restrictions on the cover or first page.11
2 Point Calib. Memory
DMS 2 remembers thethin
andthick
values so youDONTadjust them everytime you calibrate
Simply press CAL, and theSEND key twice tocomplete a 2-pt Calibration
Remembered
Values
8/13/2019 DMS 2 Thickness Gauge Training
12/34
GEIT Proprietary Information -
Subject to restrictions on the cover or first page.12
Velocity Calibration
Adjust velocity to knowvalue to calibrate system
8/13/2019 DMS 2 Thickness Gauge Training
13/34
GEIT Proprietary Information -
Subject to restrictions on the cover or first page.13
Alarm Menu
Set and turn on both Min.
and Max. alarmsIf thickness values exceedthe limits, the red LED will
light, < or > icon shows thealarm on the display.
8/13/2019 DMS 2 Thickness Gauge Training
14/34
GEIT Proprietary Information -
Subject to restrictions on the cover or first page.14
A-Gate Menu
Adjust and set
measurement gate settingsStart position
Height
Width
Also, adjust probe delay
8/13/2019 DMS 2 Thickness Gauge Training
15/34
GEIT Proprietary Information -
Subject to restrictions on the cover or first page.15
B-Gate Menu (only when in Dual-Multi Mode)
Adjust and set
measurement gate settingsStart position
Height
Width
8/13/2019 DMS 2 Thickness Gauge Training
16/34
GEIT Proprietary Information -
Subject to restrictions on the cover or first page.16
B-Scan Operation
Before Starting B-Scan
Set Range
Set Sweep Time
Set Time-Out
Set T-Min. Value (same asalarm T-Min.)
8/13/2019 DMS 2 Thickness Gauge Training
17/34
GEIT Proprietary Information -
Subject to restrictions on the cover or first page.17
B-Scan Operation
During the scan
Range, Time, T-Min itemsare not shown
No thickness display isshown
8/13/2019 DMS 2 Thickness Gauge Training
18/34
GEIT Proprietary Information -
Subject to restrictions on the cover or first page.18
B-Scan Operation
At the end of the scan
Minimum value isdisplayed
Range, Time, T-Min valuesare shown (but notchangeable)
CLEAR function is active -Pressing CLEAR will erasethe B-Scan and start the
process over.
8/13/2019 DMS 2 Thickness Gauge Training
19/34
GEIT Proprietary Information -
Subject to restrictions on the cover or first page.19
Parameter Sets
ONLY the DMS 2 allows
Parameter Sets to be savedfor both single AND dualelement probes.
Complete calibrationincluding Velocity settings.
8/13/2019 DMS 2 Thickness Gauge Training
20/34
GEIT Proprietary Information -
Subject to restrictions on the cover or first page.20
Parameter Sets
Using parameter sets allows for saving and
recalling special set-ups.Only a simple calibration check may be required
after recalling a Parameter set. Significant timesaver!!!
8/13/2019 DMS 2 Thickness Gauge Training
21/34
GEIT Proprietary Information -
Subject to restrictions on the cover or first page.21
TEST MODE
TEST key always takes you
to the TEST ModeActs like home key.
Where MENU you are inpressing the TEST key willtake you out and to theTEST menu.
8/13/2019 DMS 2 Thickness Gauge Training
22/34
GEIT Proprietary Information -
Subject to restrictions on the cover or first page.22
MIN-CAP saves time
Use the DMS 2 Min-Cap mode to always get
the minimum thickness.Fast 32Hz measurement rate.
Time Out mode allows re-couple of probe tocomplete scanning (no need to start over).
8/13/2019 DMS 2 Thickness Gauge Training
23/34
GEIT Proprietary Information -
Subject to restrictions on the cover or first page.23
Min Cap Mode
While Scanning, the
minimum value measured isdisplayed in the black box.
The live value is in big digits
8/13/2019 DMS 2 Thickness Gauge Training
24/34
GEIT Proprietary Information -
Subject to restrictions on the cover or first page.24
Time Out Bar
If you un-couple during a
Min-Cap scan, the time outbar indicated how muchtime is left that you can re-couple to continue the scan.
8/13/2019 DMS 2 Thickness Gauge Training
25/34
GEIT Proprietary Information -
Subject to restrictions on the cover or first page.25
Min-Cap Completed
When the time out has
completed, the DMS 2 willdisplay the thinnest readingtaken during the scan anddisplay the associated A-Scan.
8/13/2019 DMS 2 Thickness Gauge Training
26/34
GEIT Proprietary Information -
Subject to restrictions on the cover or first page.26
The BACK or Secondary Menus
Press the LEFT and RIGHTarrow keys at the same time
Secondary Menu System isDisplayed
8/13/2019 DMS 2 Thickness Gauge Training
27/34
GEIT Proprietary Information -
Subject to restrictions on the cover or first page.27
Secondary Menu Items
Set-Up Menu
I/O Menu
Display Menu
Global Menu
Operator Menu
8/13/2019 DMS 2 Thickness Gauge Training
28/34
GEIT Proprietary Information -
Subject to restrictions on the cover or first page.28
Multiple Update Rates
Only the DMS 2 enablesthe user to set the defaultupdate rate.
> 4 Hz
> 8 Hz> 12 Hz
> 16 Hz
> 32 Hz (B-Scan & Min-Cap Modes)
8/13/2019 DMS 2 Thickness Gauge Training
29/34
GEIT Proprietary Information -
Subject to restrictions on the cover or first page.29
DMS 2 Scans FASTER
32 Hz update rate in B-Scan and MIN-CAP modeallows users to scan faster.
Higher frequency update
rate = fast scanning withbetter coverage
Approx. Speed of 2
inches/second.
8/13/2019 DMS 2 Thickness Gauge Training
30/34
TopCOAT IS a Superior
Through CoatingMeasurement Technique
8/13/2019 DMS 2 Thickness Gauge Training
31/34
GEIT Proprietary Information -
Subject to restrictions on the cover or first page.31
TopCOAT
Superior Thru-Coating Thickness Measurement
TC-560 4 Element Probe
No need to calibrate to coating thickness
Have Auto-Velocity Mode
Temperature Limit (130 F)
DMS 2 Coating Value Prominent
8/13/2019 DMS 2 Thickness Gauge Training
32/34
GEIT Proprietary Information -
Subject to restrictions on the cover or first page.32
DMS 2 Coating Value - Prominent
With no data logger fileactive, the CoatingThickness value is largeand very easy to read
With data logger file active,small coating value is aboutthe same size as the 37DL+
text but easier to read
8/13/2019 DMS 2 Thickness Gauge Training
33/34
GEIT Proprietary Information -
Subject to restrictions on the cover or first page.33
Auto-V Mode
No Material CalibrationNeeded
No Special CalibrationBlocks
8/13/2019 DMS 2 Thickness Gauge Training
34/34
GEIT Proprietary Information - 34
Conclusion
DMS 2 is the gauge with thebest value vs. features
Works with a wider varietyof probes for solving
corrosion applicationsHas the best utility Softwareavailable