Date post: | 13-Feb-2016 |
Category: |
Documents |
Upload: | ayemyothant |
View: | 213 times |
Download: | 0 times |
contractual or other obligations.
vendor, nor does it relieve from full compliance with
calculations, test methods or materials developed or selected by
Review does not constitude acceptance of design details,
Ivar Aasen Field Development Project - pdQ
1. Accepted
2. Accepted with comments incorporated
3. NOT accepted, revise and resubmit
4. Issued for Information only
5. Interface Information as clouded (is accepted and frozen)
Rev. Date Reason for IssuePrepared
by
Reviewed
by
Approved
by
Name: Date:
Area
Code:
System
Code:
No. of
Pages
Package Title:
Project No.: Supplier Document Number: Rev.
Purchase Order No: Proj. Rev.
/
Project Document Number:
Project Tag Numbers:
400V Sub DB Wellbay Emergency Lighting And Small Power84EL0415
--
16
CIRCUIT/WIRING DIAGRAM
Page synopsispage Page comments
01 CIRCUIT/WIRING DIAGRAM Coversheet document type
02 CIRCUIT/WIRING DIAGRAM Page synopsis
03 CIRCUIT/WIRING DIAGRAM Incomer
04 CIRCUIT/WIRING DIAGRAM PE rails
05 CIRCUIT/WIRING DIAGRAM Anti-Condensation heater
06 CIRCUIT/WIRING DIAGRAM Circuit diagram
07 CIRCUIT/WIRING DIAGRAM Circuit diagram
08 CIRCUIT/WIRING DIAGRAM Circuit diagram
09 CIRCUIT/WIRING DIAGRAM Circuit diagram
10 CIRCUIT/WIRING DIAGRAM Circuit diagram
11 CIRCUIT/WIRING DIAGRAM Fault loop
12 CIRCUIT/WIRING DIAGRAM Terminal diagram -X1
13 CIRCUIT/WIRING DIAGRAM Terminal diagram -X1.1
14 CIRCUIT/WIRING DIAGRAM Terminal diagram -X2
15 CIRCUIT/WIRING DIAGRAM Terminal diagram -X2
16 CIRCUIT/WIRING DIAGRAM Terminal diagram -X3
84EL0415
84EL0415
84EL0415
84EL0415
84EL0415
84EL0415
84EL0415
84EL0415
84EL0415
84EL0415
Document type
84EL0415
84EL0415
84EL0415
84EL0415
84EL0415
400V Sub DB Wellbay Emergency Lighting And Small Power
400V Sub DB Wellbay Emergency Lighting And Small Power
400V Sub DB Wellbay Emergency Lighting And Small Power
400V Sub DB Wellbay Emergency Lighting And Small Power
400V Sub DB Wellbay Emergency Lighting And Small Power
400V Sub DB Wellbay Emergency Lighting And Small Power
400V Sub DB Wellbay Emergency Lighting And Small Power
400V Sub DB Wellbay Emergency Lighting And Small Power
400V Sub DB Wellbay Emergency Lighting And Small Power
400V Sub DB Wellbay Emergency Lighting And Small Power
400V Sub DB Wellbay Emergency Lighting And Small Power
400V Sub DB Wellbay Emergency Lighting And Small Power
400V Sub DB Wellbay Emergency Lighting And Small Power
400V Sub DB Wellbay Emergency Lighting And Small Power
400V Sub DB Wellbay Emergency Lighting And Small Power
84EL0415400V Sub DB Wellbay Emergency Lighting And Small Power
1
F
D
E
2 3 4
C
B
A
5 6 7 8
F
E
D
C
B
A
1 2 3 4 5 6 7 8
1
F
D
E
2 3 4
C
B
A
5 6 7 8
F
E
D
C
B
A
1 2 3 4 5 6 7 8
1
F
D
E
2 3 4
C
B
A
5 6 7 8
F
E
D
C
B
A
1 2 3 4 5 6 7 8
2 PE1-X1.1
21-X1 PE1 2 PE
1
F
D
E
2 3 4
C
B
A
5 6 7 8
F
E
D
C
B
A
1 2 3 4 5 6 7 8
F500
-L1-X2
95
9896.2
11 /
95
9896.2
11 /
95
9896.2
11 /
95
9896.2
11 /
95
9896.2
11 /
F500
-N
F501
-L2-X2
F501
-N
F502
-L3-X2
F502
-N
F503
-L1-X2
F503
-N
F504
-L2-X2
F504
-N
1
F
D
E
2 3 4
C
B
A
5 6 7 8
F
E
D
C
B
A
1 2 3 4 5 6 7 8
95
9896.3
11 /
95
9896.3
11 /
95
9896.3
11 /
95
9896.3
11 /
95
9896.3
11 /
F505
-L3-X2
F505
-N
F506
-L1-X2
F506
-N
F507
-L2-X2
F507
-N
F508
-L3-X2
F508
-N
F509
-L1-X2
F509
-N
1
F
D
E
2 3 4
C
B
A
5 6 7 8
F
E
D
C
B
A
1 2 3 4 5 6 7 8
95
9896.4
11 /
95
9896.4
11 /
95
9896.4
11 /
95
9896.4
11 /
95
9896.4
11 /
F510
-L2-X2
F510
-N
F511
-L3-X2
F511
-N
F512
-L1-X2
F512
-N
F513
-L2-X2
F513
-N
F514
-L3-X2
F514
-N
1
F
D
E
2 3 4
C
B
A
5 6 7 8
F
E
D
C
B
A
1 2 3 4 5 6 7 8
95
9896.5
11 /
95
9896.5
11 /
95
9896.5
11 /
95
9896.5
11 /
95
9896.5
11 /
F515
-L1-X2
F515
-N
F516
-L2-X2
F516
-N
F517
-L3-X2
F517
-N
F518
-L1-X2
F518
-N
F519
-L2-X2
F519
-N
1
F
D
E
2 3 4
C
B
A
5 6 7 8
F
E
D
C
B
A
1 2 3 4 5 6 7 8
95
9896.6
11 /
95
9896.6
11 /
95
9896.6
11 /
95
9896.6
11 /
F520
-L3-X2
F520
-N
F521
-L1-X2
F521
-N
F522
-L2-X2
F522
-N
F523
-L3-X2
F523
-N1
F
D
E
2 3 4
C
B
A
5 6 7 8
F
E
D
C
B
A
1 2 3 4 5 6 7 8
1-X3 2 PE
1
F
D
E
2 3 4
C
B
A
5 6 7 8
F
E
D
C
B
A
1 2 3 4 5 6 7 8
Source
Terminal row:
Plant/Location:Target
Function destination
-X1
+CD
-E1 +CD5 31UT61
-X1
+CD
UT61
-X1
+CD
-X1.1 +CD5 42UT62
-X1
+CD
UT62
-X1
+CD
O 5 2PEUT6-PEPE
-X1
+CD
UT6-PEPE
Target B
MK
Target co
nn
ection
pag
e
path
Plan
t
Place
Termin
al No
.:
Lin
k
Wire lin
k
Mech
.-Term
inal illu
stration
Termin
al type
Target n
ame
Co
nn
ection
pag
e
path
Plan
t
Place
Refer to interconnection
block drawings (by others)
1
F
D
E
2 3 4
C
B
A
5 6 7 8
F
E
D
C
B
A
1 2 3 4 5 6 7 8
Source
Terminal row:
Plant/Location:Target
Function destination
-X1.1
+CD
-E1 +CD5 32UT61-E2 1 5 4 +CD
-X1.1
+CD
-X1 +CD5 22UT62-E2 2 5 4 +CD
-X1.1
+CD
O 5 4PEUT6-PEPE-E2 PE 5 4 +CD
Target B
MK
Target co
nn
ection
pag
e
path
Plan
t
Place
Termin
al No
.:
Lin
k
Wire lin
k
Mech
.-Term
inal illu
stration
Termin
al type
Target n
ame
Co
nn
ection
pag
e
path
Plan
t
Place
Refer to interconnection
block drawings (by others)
1
F
D
E
2 3 4
C
B
A
5 6 7 8
F
E
D
C
B
A
1 2 3 4 5 6 7 8
Source
Terminal row:
Plant/Location:Target
Function destination
-X2
+CD
-F500 +CD6 21/2UT6F500-L1
-X2
+CD
-F500 +CD6 23/4UT6F500-N
-X2
+CD
-F501 +CD6 31/2UT6F501-L2
-X2
+CD
-F501 +CD6 33/4UT6F501-N
-X2
+CD
-F502 +CD6 41/2UT6F502-L3
-X2
+CD
-F502 +CD6 43/4UT6F502-N
-X2
+CD
-F503 +CD6 61/2UT6F503-L1
-X2
+CD
-F503 +CD6 63/4UT6F503-N
-X2
+CD
-F504 +CD6 71/2UT6F504-L2
-X2
+CD
-F504 +CD6 73/4UT6F504-N
-X2
+CD
-F505 +CD7 21/2UT6F505-L3
-X2
+CD
-F505 +CD7 23/4UT6F505-N
-X2
+CD
-F506 +CD7 31/2UT6F506-L1
-X2
+CD
-F506 +CD7 33/4UT6F506-N
-X2
+CD
-F507 +CD7 41/2UT6F507-L2
-X2
+CD
-F507 +CD7 43/4UT6F507-N
-X2
+CD
-F508 +CD7 61/2UT6F508-L3
-X2
+CD
-F508 +CD7 63/4UT6F508-N
-X2
+CD
-F509 +CD7 71/2UT6F509-L1
-X2
+CD
-F509 +CD7 73/4UT6F509-N
-X2
+CD
-F510 +CD8 21/2UT6F510-L2
-X2
+CD
-F510 +CD8 23/4UT6F510-N
-X2
+CD
-F511 +CD8 31/2UT6F511-L3
-X2
+CD
-F511 +CD8 33/4UT6F511-N
-X2
+CD
-F512 +CD8 41/2UT6F512-L1
-X2
+CD
-F512 +CD8 43/4UT6F512-N
-X2
+CD
-F513 +CD8 61/2UT6F513-L2
-X2
+CD
-F513 +CD8 63/4UT6F513-N
-X2
+CD
-F514 +CD8 71/2UT6F514-L3
Target B
MK
Target co
nn
ection
pag
e
path
Plan
t
Place
Termin
al No
.:
Lin
k
Wire lin
k
Mech
.-Term
inal illu
stration
Termin
al type
Target n
ame
Co
nn
ection
pag
e
path
Plan
t
Place
Refer to interconnection
block drawings (by others)
1
F
D
E
2 3 4
C
B
A
5 6 7 8
F
E
D
C
B
A
1 2 3 4 5 6 7 8
Source
Terminal row:
Plant/Location:Target
Function destination
-X2
+CD
-F514 +CD8 73/4UT6F514-N
-X2
+CD
-F515 +CD9 21/2UT6F515-L1
-X2
+CD
-F515 +CD9 23/4UT6F515-N
-X2
+CD
-F516 +CD9 31/2UT6F516-L2
-X2
+CD
-F516 +CD9 33/4UT6F516-N
-X2
+CD
-F517 +CD9 41/2UT6F517-L3
-X2
+CD
-F517 +CD9 43/4UT6F517-N
-X2
+CD
-F518 +CD9 61/2UT6F518-L1
-X2
+CD
-F518 +CD9 63/4UT6F518-N
-X2
+CD
-F519 +CD9 71/2UT6F519-L2
-X2
+CD
-F519 +CD9 73/4UT6F519-N
-X2
+CD
-F520 +CD10 21/2UT6F520-L3
-X2
+CD
-F520 +CD10 23/4UT6F520-N
-X2
+CD
-F521 +CD10 31/2UT6F521-L1
-X2
+CD
-F521 +CD10 33/4UT6F521-N
-X2
+CD
-F522 +CD10 41/2UT6F522-L2
-X2
+CD
-F522 +CD10 43/4UT6F522-N
-X2
+CD
-F523 +CD10 61/2UT6F523-L3
-X2
+CD
-F523 +CD10 63/4UT6F523-N
Target B
MK
Target co
nn
ection
pag
e
path
Plan
t
Place
Termin
al No
.:
Lin
k
Wire lin
k
Mech
.-Term
inal illu
stration
Termin
al type
Target n
ame
Co
nn
ection
pag
e
path
Plan
t
Place
Refer to interconnection
block drawings (by others)
1
F
D
E
2 3 4
C
B
A
5 6 7 8
F
E
D
C
B
A
1 2 3 4 5 6 7 8
Source
Terminal row:
Plant/Location:Target
Function destination
-X3
+CD
-F500 +CD11 298UT61
-X3
+CD
UT62
-X3
+CD
UT6-PEPE
Target B
MK
Target co
nn
ection
pag
e
path
Plan
t
Place
Termin
al No
.:
Lin
k
Wire lin
k
Mech
.-Term
inal illu
stration
Termin
al type
Target n
ame
Co
nn
ection
pag
e
path
Plan
t
Place
Refer to interconnection
block drawings (by others)
1
F
D
E
2 3 4
C
B
A
5 6 7 8
F
E
D
C
B
A
1 2 3 4 5 6 7 8