Page 1: Document1 - Universiti Teknologi Malaysiacivil.utm.my/ethesis/files/...Of...Temperature-Loading-Zuraimi-Johari.pdf · Sifat fizikal konkrithanya bertumpu kepada ukuran dimensi fizikal,
Page 2: Document1 - Universiti Teknologi Malaysiacivil.utm.my/ethesis/files/...Of...Temperature-Loading-Zuraimi-Johari.pdf · Sifat fizikal konkrithanya bertumpu kepada ukuran dimensi fizikal,
Page 3: Document1 - Universiti Teknologi Malaysiacivil.utm.my/ethesis/files/...Of...Temperature-Loading-Zuraimi-Johari.pdf · Sifat fizikal konkrithanya bertumpu kepada ukuran dimensi fizikal,
Page 4: Document1 - Universiti Teknologi Malaysiacivil.utm.my/ethesis/files/...Of...Temperature-Loading-Zuraimi-Johari.pdf · Sifat fizikal konkrithanya bertumpu kepada ukuran dimensi fizikal,
Page 5: Document1 - Universiti Teknologi Malaysiacivil.utm.my/ethesis/files/...Of...Temperature-Loading-Zuraimi-Johari.pdf · Sifat fizikal konkrithanya bertumpu kepada ukuran dimensi fizikal,
Page 6: Document1 - Universiti Teknologi Malaysiacivil.utm.my/ethesis/files/...Of...Temperature-Loading-Zuraimi-Johari.pdf · Sifat fizikal konkrithanya bertumpu kepada ukuran dimensi fizikal,

iii

To my beloved wife, children and all family

Page 7: Document1 - Universiti Teknologi Malaysiacivil.utm.my/ethesis/files/...Of...Temperature-Loading-Zuraimi-Johari.pdf · Sifat fizikal konkrithanya bertumpu kepada ukuran dimensi fizikal,

iv

ACKNOWLEDGEMENT

In preparing this thesis, I was in contact with many people, researchers,

academician and practitioner. They have contributed towards my understanding and

thoughts. In particular, I wish to express my sincere appreciation to my main

supervisor, Associates Professor Dr Mohammad bin Ismail, for encouragement,

guidance, critics and friendship. I a so very thankful to all my family especially to

my beloved wife Nor Jalilah Idris, My son Husni Zahirulhaq Zuraimi and my

daughter Husna Zulaikha Zuraimi for their support and motivation. Without their

continued support and interest, this thesis would not have been the same as presented

here.

I am also indebted to librarian at UTM Skudai and Jln Semarak, librarian at

Perpustakaan Negara, Technician at UTM Structure Laboratory and Technician at

SIRIM laboratory for their assistance in supplying the relevant literature and helping

to conduct the laboratory testing.

My fellow postgraduate students should also be recognized for their

support. My sincere appreciations also extend to all my colleagues and others who

have provided assistance at various occasions. Their views and tips are useful indeed.

Page 8: Document1 - Universiti Teknologi Malaysiacivil.utm.my/ethesis/files/...Of...Temperature-Loading-Zuraimi-Johari.pdf · Sifat fizikal konkrithanya bertumpu kepada ukuran dimensi fizikal,

v

ABSTRACT

The research effort aim characterized the mechanical behavior of high

strength concrete at high temperature loading. Mechanical behaviors of two different

type of concrete were measured after heated to 2000C, 4000C, 8000C and 10000C.

The average compressive strength of these two types of concrete before being too

exposed to the high temperature is 30MPa and 60MPa.

The following physical behaviors were measured for each concrete

specimen prior to high temperature exposure: physical dimension, mass (initial mass,

heated mass and total mass loss) and longitudinal resonance frequency (before and

after heating). Before heating specimens until the selected temperature, a baseline

data or control data set was generated for each type of concrete after exposure to a

nominal room temperature (250C).

The selected temperatures were accomplished by placing the specimens

into a low temperature electrical furnace for temperature below than 3000C and used

high temperature electrical furnace for temperature greater than 3000C. Then the

specimens will heat with rate of heating 2000C per hour or 50C per minute until

reached steady state condition at one of selected temperature. Specimen will heat

with a total heating period of 7 hours before cooled to room temperature for 24

hours. The specimens were weighed and resonance frequency was measured again

(after heating). The compressive strength of each specimen was measured. Result

from this research may be useful for assessing post fire behavior properties of high

strength concrete.

Page 9: Document1 - Universiti Teknologi Malaysiacivil.utm.my/ethesis/files/...Of...Temperature-Loading-Zuraimi-Johari.pdf · Sifat fizikal konkrithanya bertumpu kepada ukuran dimensi fizikal,

vi

ABSTRAK

Penyelidikan ini adalah bertujuan untuk mengkaji sifat-sifat mekanikal

konkrit berkekuatan tinggi apabila dibakar pada suhu yang tinggi. Sifat mekanikal

konkrit hanya bertumpu pada suhu 2000C, 4000C, 8000C dan 10000C. Dua jenis

konkrit akan digunakan didalam penyelidikan ini iaitu kunkrit grad 30 MPa dan

konkrit grad 60 MPa.

Sifat fizikal konkrithanya bertumpu kepada ukuran dimensi fizikal, berat

(erat permulaan, berat selepas di baker dan jumlah kehilangan berat) dan perintangan

frekunsi resonan (sebelum dan selepas di baker). Sebelum specimen dibakar, data

ujuan di perolehi akan digunakan sebagai data kawalan bagi kedua-dua jenis konkrit.

Pembakaran specimen akan menggunakan dua jenis oven relau iaitu relau bersuhu

rendah (kurang dari 3000C) dan relau bersuhu tinggi (lebih dari 3000C). specimen

akan di baker pada kadar 2000C sejam atau 50C seminit. Pembakaran anak dijalankan

selama tujuh jam sebelum di biarkan menyejuk pada suhu bilik selama 24 jam. Berat

dan frekunsi resonan disukat sekali lagi (sesudah dipanaskan). Setelah itu ujian

mampatan dijalankan. Data dan keputusan penyelidikan ini boleh digubakan untuk

melihat kesan konkrit berkekuatan tinggi setelah dibakar pada suhu yang tinggi.

Page 10: Document1 - Universiti Teknologi Malaysiacivil.utm.my/ethesis/files/...Of...Temperature-Loading-Zuraimi-Johari.pdf · Sifat fizikal konkrithanya bertumpu kepada ukuran dimensi fizikal,

vii

TABLE OF CONTENTS

CHAPTER TITLE PAGE

1 INTRODUCTIONS

1.1 Objective 3

1.2 Scope of Research 3

1.3 Research Methodology 4

2 LITERATURE REVIEW

2.0 Concrete Materials 5

2.0.1 Cement 5

2.0.2 Aggregate 8

2.0.2.1 Essential Requirement 8

2.0.2.2 Partial Shape 9

2.0.2.3 Size of Aggregate 9

2.0.2.4 Grade of Aggregate 9

2.0.2.5 Mineralogy 13

2.0.2.6 Absorption 13

2.0.3 Water 14

2.1 Concrete Mix 14

Page 11: Document1 - Universiti Teknologi Malaysiacivil.utm.my/ethesis/files/...Of...Temperature-Loading-Zuraimi-Johari.pdf · Sifat fizikal konkrithanya bertumpu kepada ukuran dimensi fizikal,

viii

2.2 Effect of Mix Constituents 15

2.2.1 Cement Content 15

2.2.2 Aggregate 15

2.2.3 Water 16

2.3 General Concrete Properties 16

2.3.1 Specific Gravity 16

2.3.2 Concrete Density 17

2.3.3 Water Absorption, Porosity and

Permeability 17

2.3.4 Thermal Expansion 18

2.3.5 Specific Heat 20

2.3.6 Thermal Diffusivity 20

2.3.7 Thermal Conductivity 21

2.3.8 Concrete Strength 22

2.3.9 Modulus of Elasticity 23

2.4 Properties of High Strength Concrete 25

2.4.1 Stress Strain Behavior in Uniaxial

Compression 25

2.4.2 Poisson’s Ratio 28

2.4.3 Tensile Splitting Strength 28

2.4.4 Fatique Strength 29

2.4.5 Thermal Properties 29

2.4.6 Heat Evolution due to Hydration 30

2.4.7 Strength gain with age 31

2.5 Concrete Testing 33

2.5.1 Slump Test 33

2.5.2 Compressive Strength 34

2.5.3 UPV Test 34

Page 12: Document1 - Universiti Teknologi Malaysiacivil.utm.my/ethesis/files/...Of...Temperature-Loading-Zuraimi-Johari.pdf · Sifat fizikal konkrithanya bertumpu kepada ukuran dimensi fizikal,

ix

3 RESEARCH PROCEDURES

3.0 Research Design and Procedures 37

3.0.1 Test Specimens 37

3.0.2 Concrete Mix Formulation 38

3.0.2.1 Cement Content 39

3.0.2.2 Water Content 39

3.0.2.3 Aggregate Content 40

3.0.3 Trial Mix 40

3.0.4 Numbers Specimen tested 41

3.0.5 Curing Requirement 41

3.0.6 Test Apparatus 42

3.0.6.1 Specimens Dimensions 42

3.0.6.2 Mass 42

3.0.6.3 Resonant Frequency (UPV Test) 43

3.0.6.4 Compressive Strength 43

3.0.6.5 Electrical Furnace 43

3.1 Assumption and Limitations 44

4 EXPERIMENTAL PROCEDURES

4.0 Experimental Procedures 45

4.1 Testing procedures 47

4.2 Test Result and Analysis 51

4.2.1 Specimens Characteristic After Heating 55

4.2.2 Mass Loss 59

4.2.3 Compressive Strength 64

4.2.4 UPV Test 67

Page 13: Document1 - Universiti Teknologi Malaysiacivil.utm.my/ethesis/files/...Of...Temperature-Loading-Zuraimi-Johari.pdf · Sifat fizikal konkrithanya bertumpu kepada ukuran dimensi fizikal,

x

5 DISCUSSIONS

5.0 Mass Loss 73

5.1 Compressive Strength 78

5.2 Pulse Velocity 82

6 CONCLUSIONS 89

References

APPENDICES

APPENDIX A Detail Design mix for concrete grade 60 MPa

APPENDIX B Detail Design mix for concrete grade 30 MPa

APPENDIX C Trial Mix result for concrete grade 60 MPa

APPENDIX D Trial Mix result for concrete grade 30 MPa

APPENDIX E Rebound Hammer Result for Concrete grade 60 MPa

APPENDIX F Rebound Hammer Result for Concrete grade 30 MPa

Page 14: Document1 - Universiti Teknologi Malaysiacivil.utm.my/ethesis/files/...Of...Temperature-Loading-Zuraimi-Johari.pdf · Sifat fizikal konkrithanya bertumpu kepada ukuran dimensi fizikal,

xi

LIST OF TABLES

TABLE NO TITLE PAGE

1 Grading Limits For Coarse Aggregate (BS 882) 12

2 Grading Limits For Fine Aggregate (BS 882) 13

3 Typical Value Of Thermal Conductivity Of

Concrete [High Performance Concrete In Serve

Environment, 1993] 22

4 Description Of Workability And Magnitude Of Slump 34

5 Concrete Formulation Grade 30mpa And 60mpa

To Be Used. 39

6 Cube Quantity Will Be Test. 42

7 Experiment Result For Concrete Grade 60 Mpa 53

8 Experiment Result For Concrete Grade 30 Mpa 54

9 Percentage Mass Loss And The Pulse Velocity Percentage

Reduction For Concrete Grade 30 Mpa 55

10 Percentage Mass Loss And The Pulse Velocity

Percentage Reduction For Concrete Grade 60 Mpa 55

Page 15: Document1 - Universiti Teknologi Malaysiacivil.utm.my/ethesis/files/...Of...Temperature-Loading-Zuraimi-Johari.pdf · Sifat fizikal konkrithanya bertumpu kepada ukuran dimensi fizikal,

xii

11 Compressive Strength Result For Normal Concrete

Grade 30 Mpa 65

12 Compressive Strength Result For High Strength Concrete

Grade 60 Mpa 66

13 Percentage Concrete Composition Per Meter Cubic 75

14 Pulse Velocity Indication 83

15 Concrete Grade 30 Mpa Quality 84

16 Concrete Grade 60 Mpa Quality 84

Page 16: Document1 - Universiti Teknologi Malaysiacivil.utm.my/ethesis/files/...Of...Temperature-Loading-Zuraimi-Johari.pdf · Sifat fizikal konkrithanya bertumpu kepada ukuran dimensi fizikal,

xiii

LIST OF FIGURES

FIGURES NO TITLE PAGE

1 Research Methodology Flow Chart 5

2 Effects Of Concrete Compressive

Strength [High Strength Concrete, 1987] 8

3 Relation Between Ambient Relative Humidity

And The Linear Coefficient Of Thermal

Expansion Of Neat Cement Paste Cured

Normally And High-Pressure Steam Cured

[Neville, 1995] 19

4 The Linear Coefficient Of Thermal Expansion

Of Neat Cement Paste At Different Ages

[Neville, 1995] 20

5 Compressive Strength Of Concrete At High

Temperature [High Performance Concrete In

Serve Environment, 1993] 24

6 Influence Of Temperature On Modulus

Elasticity Of Concrete [Neville, 1995] 25

7 Complete Compressive Stress-Strain Curves

[High Strength Concrete,1987] 27

Page 17: Document1 - Universiti Teknologi Malaysiacivil.utm.my/ethesis/files/...Of...Temperature-Loading-Zuraimi-Johari.pdf · Sifat fizikal konkrithanya bertumpu kepada ukuran dimensi fizikal,

xiv

8 Axial Stress Versus Axial Strain And Lateral

Strain For Plain Normal Weight Concrete

[High Strength Concrete, 1987] 28

9 Temperature Rise Of High Strength Field-Cast 31

10 Normalized Strength Gain With Age For Moist

Cured Concrete. 33

11 UPV Direct Method 36

12 UPV Indirect Method 37

13 Mass Loosing After Exposed To Selected

Temperature For Mixture II (Grade 30 Mpa) 61

14 Mass Loosing After Exposed To Selected

Temperature For Mixture I (Grade 60 Mpa) 62

15 Comparison Of Mass Loosing Between

Grade 30mpa And Grade 60 Mpa.. 63

16 Percentage Mass Loss For Grade 60 Mpa And

Grade 30 Mpa 64

17 Compressive Strength Reduction Between

Grade 60 Mpa And Grade 30 Mpa 67

18 Pulse Velocity Concrete Grade 60 Mpa

Before And After Exposed To Elevated

Temperature. 69

Page 18: Document1 - Universiti Teknologi Malaysiacivil.utm.my/ethesis/files/...Of...Temperature-Loading-Zuraimi-Johari.pdf · Sifat fizikal konkrithanya bertumpu kepada ukuran dimensi fizikal,

xv

19 Pulse Velocity Concrete Grade 30 Mpa

Before And After Exposed To Elevated

Temperature 71

20 Percentage Reduction After Exposed To

Elevated Temperature For Concrete

Grade 30 Mpa And Concrete Grade 60 Mpa 73

21 Illustration Of Evaporation Process For

Concrete Grade 30 Mpa 77

22 Illustration Of Evaporation Process For

Concrete Grade 60 Mpa 78

23 Illustration of Micro Cracking Occurred At

Weak Area Dring The Heating Process 81

24 Illustration of Micro Cracking Occurred At

Aggregate Surface Dring The Heating Process 82

25 Illustration of Pulse Velocity for Concrete

Specimens Before Exposed To Elevated

Temperatures 86

26 Illustration of Pulse Velocity for Concrete

Specimens After Exposed To Elevated

Temperatures 87

Page 19: Document1 - Universiti Teknologi Malaysiacivil.utm.my/ethesis/files/...Of...Temperature-Loading-Zuraimi-Johari.pdf · Sifat fizikal konkrithanya bertumpu kepada ukuran dimensi fizikal,

xvi

LIST OF PHOTOS

PHOTOS NO TITLE PAGE

1 Cube Position In Compressive Machine For

Compressive Strength Test 49

2 Maximum Load Applied Were Recorded 49

3 Oven Furnace Used For Temperature

4000C And Above 51

4 Specimens Allowed Cooling Down In

Room Temperature Before Test 51

5 Specimen Before Exposed To Elevated Temperature 56

6 Specimen Condition At Room Temperature

(Grade 30 Mpa) 57

7 Specimen After Heating At Temperature 2000C.

Hairline Cracks Appearance At Certain Portion

(Grade 30 Mpa). 57

8 Specimen Look More Whitish And More

Hairline Crack Appearance At The Specimen

Surface (Grade 60 MPa). 58

Page 20: Document1 - Universiti Teknologi Malaysiacivil.utm.my/ethesis/files/...Of...Temperature-Loading-Zuraimi-Johari.pdf · Sifat fizikal konkrithanya bertumpu kepada ukuran dimensi fizikal,

xvii

9 Specimen Spalled In Temperature 8000C For

Grade 60 59

10 At 10000C Severe Spalling Were Obsessed.

Only Visual Inspections Were Carried Out For

Grade 60 MPa. 59

Page 21: Document1 - Universiti Teknologi Malaysiacivil.utm.my/ethesis/files/...Of...Temperature-Loading-Zuraimi-Johari.pdf · Sifat fizikal konkrithanya bertumpu kepada ukuran dimensi fizikal,

xviii

LIST OF APPENDICES

APPENDIX NO TITLE PAGE

A Detail Design mix for concrete grade 60 Mpa 92

B Detail Design mix for concrete grade 30 Mpa 94

C Trial Mix result for concrete grade 60 MPa 96

D Trial Mix result for concrete grade 30 MPa 97

E Rebound Hammer Result for Concrete

grade 60 Mpa 98

F Rebound Hammer Result for Concrete

grade 30 Mpa 100

Page 22: Document1 - Universiti Teknologi Malaysiacivil.utm.my/ethesis/files/...Of...Temperature-Loading-Zuraimi-Johari.pdf · Sifat fizikal konkrithanya bertumpu kepada ukuran dimensi fizikal,

1

CHAPTER 1

INTRODUCTION

1.0 Introduction

Fire induced collapsed of the world trade centre (WTC), New York on 9th

September 2001was highlighted that the important of performance construction

materials at high temperature loading especially for the high rise building.

The high strength concrete (HSC) is a materials often used in high rise

building structure design. HSC can be manufactured by most concrete plane using

the state of additives such as silica fume and super plasticizer or water reducing

admixture. In the high rise building structure, the HSC offer significant economical

and achievement advantages over ordinary concrete or normal strength concrete

(NSC).

However, results of many recent fire tests have shown that there are much

different this of two types of concrete HSC and NSC during the high temperature

exposure. These include the different in mechanical behavior properties such as

compressive strength retained by HSC and NSC at high temperature. HSC specimen

show fail by explosive spalling when subjected to rapid heating.

Page 23: Document1 - Universiti Teknologi Malaysiacivil.utm.my/ethesis/files/...Of...Temperature-Loading-Zuraimi-Johari.pdf · Sifat fizikal konkrithanya bertumpu kepada ukuran dimensi fizikal,

2

“Malhotra (1956), Zoldners (1960), Davis (1967), Abrams (1971), Faiyadh

(1989),Khoury (1992) and Noumowe et. Al (1994) has reported the effect of high

temperature exposure on the properties of concrete. Several mechanism have

identified for the deterioration of concrete due to high temperatures. These include

decomposition of the calcium hydroxide into lime and water, expansion of lime on

re-hydration, destruction of gel structure, phase transformation in some types of

aggregate and development of micro cracks due to thermal incompatibility between

cement paste matrix and aggregate phase”

The type of aggregate also influenced the response of concrete to high

temperature. On this research, assumes that all the aggregate and other materials used

follow the British Standard, ASTM or equivalent.

At the end of this research, the mechanical behavior of HSC exposure in high

temperature will know and it will assist in the development of new standard for used

the HSC. These data produced may be being able to assist in the development of new

formulation of HSC that are less prone to explosive spalling.

Page 24: Document1 - Universiti Teknologi Malaysiacivil.utm.my/ethesis/files/...Of...Temperature-Loading-Zuraimi-Johari.pdf · Sifat fizikal konkrithanya bertumpu kepada ukuran dimensi fizikal,

3

1.1 Objective

Generally the main objective of this research is to study the mechanical

properties of high strength concrete after heated in high temperature. In detail the

objective of this research as a following:

• To find out the mechanical behavior of High Strength Concrete at

temperature 2000C to 10000C

• Determine the percentage of HSC strength reduction by increasing

temperature loading from 2000C to 10000C with rating 2000C per hour.

• Determine a systematic comparison of result of high temperature test on

Normal Strength Concrete (NSC – grade 30 MPa) and High Strength

Concrete (HSC – grade 60 MPa) specimen to examine the effect of high

temperature exposure to the mechanical properties of concrete with

different original compressive strength.

1.2 Scope of Research

The mechanical properties of high strength concrete at high temperature

influenced by type of aggregate properties, water content, admixture content and etc.

in this research, the scope will covered following:

• Concrete design mix for both type of concrete is used BS 8110. The

types of concrete to be used, 30MPa & 60Mpa. The entire test

involved before heated in high temperature will be conduct and the

result of testing will be used as a controlled data.

• Only the unstressed residual property test will be done which mean

the specimens allowed to cool down within 24 hours after heated on

the target temperature.

Page 25: Document1 - Universiti Teknologi Malaysiacivil.utm.my/ethesis/files/...Of...Temperature-Loading-Zuraimi-Johari.pdf · Sifat fizikal konkrithanya bertumpu kepada ukuran dimensi fizikal,

4

Value of the compressive strength will be recorded and analyzed for the

temperature 2000C, 4000C, 8000C and 10000C or until specimens explode which

reached first

1.3 Research Methodology

The research methodology started from find the problem and then to

resolved the problem. All stage to get the result as shown in the

following Figure 1.

Figure 1: Research Methodology Flow Chart

Find the problem to be resolved from article, internet etc

Analyzed the problem and list down the objective for this

research

Literature Input

Internet

Reference Book

Standard (BS, MS, ASTM,

etc)

Article / Seminar Note/

Proceeding

Design & Experimental Process

Get The Result & Analyzed

Relate the result analyzed and literature review

Conclusion

Trial Mix

Page 26: Document1 - Universiti Teknologi Malaysiacivil.utm.my/ethesis/files/...Of...Temperature-Loading-Zuraimi-Johari.pdf · Sifat fizikal konkrithanya bertumpu kepada ukuran dimensi fizikal,

5

CHAPTER 2

LITERATURE REVIEW

2.0 Concrete Materials

2.0.1 Cements

The most widely used cement in country is ordinary Portland cement.

Heating limestone and clay or other suiTable raw materials together from a clinker

rich in calcium silicates makes it. The clinker is ground to a fine powder with small

proportion of gypsum (calcium sulfate), which regulates the rate of setting when the

cement is mixed with water.

By incorporating other materials during manufacture generally when the

clinker is being ground an even wider range of cement is produced Portland blast

furnace, masonry, colored, oil well, water repellent and hydrophobic cement.

The choice of Portland cement for high strength concrete is extremely

important. Unless high initial strength is the objective such as in pre stress concrete,

there is no need to use a type III cement. The different brand will have different

strength development characteristics because of the variation in compound

composition and fines that are permitted by ASTM C 150.

Page 27: Document1 - Universiti Teknologi Malaysiacivil.utm.my/ethesis/files/...Of...Temperature-Loading-Zuraimi-Johari.pdf · Sifat fizikal konkrithanya bertumpu kepada ukuran dimensi fizikal,

6

Initially silo test certificate should be obtained from potential supplier for

the previous 6 to 12 month not only gives an indication on strength characteristic

from the ASTM C 109 mortar cube test. If the tricalcium silicate contents various by

more than 4 percent the ignition loss by more than 0.5 percent or the fines by more

than 375 cm2 / g then problem in maintaining a uniform high strength may result.

Sulfate level should be maintained at optimum with variation limited to ± 0.20

percent.

High cement content can be expected to result in a high temperature rise

within the concrete. For example the temperature in the 1.2 m square column used in

water tower place, which contained 502 kg/m3, rose to 660C from 240C during

hydration. The heat was dissipated within 6 days without harmful effect. Howe ever

when the temperature rise is expected to be a problem a type II low heat of hydration

cement can be used, provided it meets the strength producing requirements.

A further consideration is optimization of the cement admixture system.

The exact effect of a water reduction agent on water requirement for example will

depend on the cement characteristic and cement content. The following Figure has

shown an effect of cement on compressive strength.

Page 28: Document1 - Universiti Teknologi Malaysiacivil.utm.my/ethesis/files/...Of...Temperature-Loading-Zuraimi-Johari.pdf · Sifat fizikal konkrithanya bertumpu kepada ukuran dimensi fizikal,

7

Figure 2: Effects of Concrete Compressive Strength [High Strength Concrete, 1987]

Page 29: Document1 - Universiti Teknologi Malaysiacivil.utm.my/ethesis/files/...Of...Temperature-Loading-Zuraimi-Johari.pdf · Sifat fizikal konkrithanya bertumpu kepada ukuran dimensi fizikal,

8

2.0.2 Aggregate

The term ‘aggregate’ is used to describe the gravel, crushed stones and

other materials, which are mixed with cement and water to make concrete. As

aggregate from the bulk of the volume of concrete the selection of suiTable materials

is important. Gravel, sand and crushed stone such as granite blast and the harder type

of limestone and sand stone, are in common use as aggregate. A list and their

petrological group is given in section 2 of BS 812 which is describe test for

ascertaining whether the aggregate is suiTable for concrete works, but for natural

aggregate the test result are given in BS 882.

2.0.2.1 Essential requirement

The most important for aggregate to use in concrete are durability and

cleanness.

For the durability, aggregate should be hard and not contain materials,

which are likely to decomposed, or change the volume when exposed to the weather

or to affect the reinforcement. Aggregate must be free from undesirable materials

such as coal, pyrites and lumps of clay: coal may swell; pyrites may decompose

causing iron oxide stain to appear on the concrete surface. In high strength concrete,

the crushing value or impact value, density or mineralogical type may be specified.

Aggregate also should be clean and free from organic impurities. High

containing organic materials in aggregate make poor concrete. The particles should

be free from coating of dust or clay, as these prevent the proper bonding of materials.

Gravel and sand are usually washed by the supplier to remove clay, silt and other

impurities materials. However washing must not be carry to such as extend that all

fine materials passing the 300µm.

Page 30: Document1 - Universiti Teknologi Malaysiacivil.utm.my/ethesis/files/...Of...Temperature-Loading-Zuraimi-Johari.pdf · Sifat fizikal konkrithanya bertumpu kepada ukuran dimensi fizikal,

9

2.0.2.2 Particle Shape

Many studied shown the crushed stone produces high strength then round

gravel. The reasons for this are because the greater mechanical bond which can

develop with angular particles.

2.0.2.3 Size of aggregate

The size of aggregate normally governs by the type of work to be done. For

reinforced concrete it should be such that the concrete can be placed without

difficulty surrounding all reinforcement and filling the corners of the formwork. The

course aggregate for reinforce concrete have nominal maximum size of 20mm

In massive structure sometimes used the larger piece of aggregate known as

‘plums’.

2.0.2.4 Grading of aggregate

Aggregate can be graded in two grades. First grade is fine aggregate and the

other is coarse aggregate.

The optimum grading of fine aggregate for high strength concrete is

determined more by its effect on water requirement than on physical packing. The

sand with a fineness modulus below 2.5 gave the concrete a sticky consistency

Page 31: Document1 - Universiti Teknologi Malaysiacivil.utm.my/ethesis/files/...Of...Temperature-Loading-Zuraimi-Johari.pdf · Sifat fizikal konkrithanya bertumpu kepada ukuran dimensi fizikal,

10

making it difficult to compact. Sand with fineness of about 3.0 gave is the best

workability and compressive strength.

High strength concrete typically contains such high content of fine

cementations materials that the grading of the aggregate used relatively not important

compare to normal or conventional concrete. A national Crushed Stone Association

recommended in the interest of reducing the water requirement. The amount passing

the no 50 and 100 sieves should be kept low but still within requirement of ASTM

C33.

For the type of coarse aggregate, shown that for optimum compressive

strength with high cement content and low water cement ratios the maximum size of

coarse aggregate should be kept to a minimum at 12.7mm or 9.5mm. Maximum size

is within 19 mm to 25.4mm.

Reported by previous researcher Cordon and Gillespie felt that the strength

increased were causes by reduction in average bond stress due to the increased

surface are of the individual aggregate. Alexander found that the bond to a 76mm

aggregate particle was only about 0.1 of that to 13mm particle. He also stated that

except for very good or very bad aggregate the bond strength was about 50 to 60

percent of the paste strength at 7 days. Smaller aggregate also considered producing

higher concrete strength because of less severe concentration of stress around the

particles, which are caused by, different between the elastic moduli of the paste and

the aggregate. Table 1 and 2 shown the grading limit for both of aggregate type,

which is derived from BS 882


Recommended