PRASAR BHARATI (Broadcasting corporation of India)
DOORDARSHAN MAINTENANCE CENTRE, KARNAL-132 001 E-mail: [email protected]
DMC/KNL/M.R./2011-12/ Dated :06.07.2011
To
The Chief Engineer (N/Z) DDM Akashvani & Doordarshan Jamnagar House, Shahjahan Road, New Delhi – 110 011.
Sub: Technical monthly Report June 2011
Sir,
Kindly find enclosed here with Technical Monthly Report for the month of
June 2011 of LPT’s under DMC Karnal.
Yours Faithfully
(A.K.Wadhwa) Assistant Station Engineer
DMC Karnal
Encls: -
Monthly Report in new proforma sent through e-mail.
MONTHLY REPORT OF DMC, KARNAL
For the month of June 2011
1. GENERAL 1.1 DETAILS OF IMPORTANT TECHNICAL WORK DONE AT
LPTs / VLPTs DURING THE MONTH
Name of Station Details of the important technical work done REMARKS
DMC Karnal
LPT Karnal
1. General maintenance of transmitter undertaken, all modules i.e. SMPS, Switcher & all input/monitor rack equipments cleaned and loose connections tightened. 2. All necessary precautions for smooth working of transmitter were undertaken.
LPT Kuru-
kshetra
1. The Earth Resistance of 5 pits has been measured using Waco Digital Earth Resistance meter.
2. PA s Combiner unit attended to remove loose connection of combiner on heat sink which was causing reflections in Lower PA.
3. Preventive Maintenance of 15 KVA DG has been carried out. 4. All the electrical connections checked and tightened. 5. Monthly Preventive maintenance of the transmitter has been carried out.
6. All necessary precautions to run the transmitter smoothly have been undertaken.
LPT Ambala
1. General maintenance of transmitter undertaken. 2 Preventive Maintenance of AC has been carried out. 3. Preventive Maintenance of 15 KVA DG has been carried out 4. Control card of AVR repaired and one No.40 Amp of 10KVA AVR replaced as 40 Amp DP of AVR got heated up during course of operation. 5. Faulty single phase meter of DG panel replaced with new Volt meter.
LPT Yamuna--
agar
1. General cleaning & maintenance of Transmitter carried out. 2. Three Nos MCB 32 Amp, 20 Amp & 6 Amp found damaged replaced with new MCB s. One no DP 20 Amp also replaced in supply panel. 3. VIVA make AC repaired after replacing its compressor thimble. Now AC is working O.K.
LPT Jind
1. General Maintenance of Transmitter. 2. One 45mfd 440 volt capacitor was leaky in AC. Anew capacitor of same capacity taken from store and replaced. AC is now working o.k. 3. General maintenance of D.G set has been carried out.
LPT Kaithal
1 The routine maintenance carried out on transmitter rack, input rack and Monitoring rack. All the units dust blown off with the help of vacuum cleaner and Clean with soft cloth.
1. DETAILS OF OFFICERS / STAFF RELIEVED / JOINED FROM / AT DURING THE MONTH
DETAILS OF OFFICERS / STAFF JOINED DURING THE MONTH Name Desig-
nation Emp. No. Relieved from
Station Relieving
Date Joined
at Joining
date Transfer order No. and Date
DETAILS OF OFFICERS / STAFF RELIEVED DURING
THE MONTH Name Designation Emp. No. Relieved
from StationRelieving
Date To join at Transfer order
No. and Date
-----Nil---- 2. TOUR / LEAVE DETAILS OF ENGG. HEAD OF OFFICE /
CONTROLLING OFFICERS DURING THE MONTH
NAME OF OFFICER TOUR DETAILS PERIOD OF E.L. / M.
L. ALONGWITH ITS NATURE PERIOD PLACE
Sh. A.K.Wadhwa SE DMC Karnal
Sh. Rameshwar Prasad AE LPT Yamuna nagar
LPT Ambala
V.K. Jain, S.E.A. ----- ------- 16.6.2011 to 19.06.2011
EL (04 days) Sh. Anil Kumar, AE LPT Kurukshetra -
Sh. V P Sharma, AE LPT Kaithal 28.06.2011 DMC KNL Tour 20.6.11 to 24.6.11 EL
1.4 TRAINING DETAILS OF ENGG. HEAD OF OFFICE / STAFF
DURING THE MONTH NAME OF OFFICER /
STAFF DESIGNATION
PERIOD PLACE NAME OF
COURSE From To
1.5 DETAILS OF NEW EQUIPMENTS RECEIVED AT DMC / LPTs / VLPTs DURING LAST SIX MONTHS
Name of Station
Name of equipment
Date of receipt of equipment
Received from
Whether put in to circuit
Performance of equipment
Remarks
LPT Yamuna Nagar
Scopus IRD 2900 25.05.11 DMC
Karnal Yes ok
LPT Kaithal New DG Bty set Feb.11 DMC
Karnal no ok
Mono Bloc Pump June 11 DMC
Karnal Not yet --
LPT Kurukshetra
300W PA with 30 V /50
A Power supply
31.03.2011 CP&S New Delhi
Working O.K. O.K.
. 1.5 TR
Window AC Make
SAMSUNG
May 11 DMC Karnal Yes ok
LPT Karnal
300W PA with 30 V /50
A Power supply
31.03.2011 CP&S New Delhi
Working O.K. O.K.
Scopus IRD 2900 09.05.11 DMC
Karnal Yes ok
1.6 DETAILS OF SCROLLER
Name of Station
Working Status of Scroller-1
Working Status of Scroller-2
Revenue generated in
current month
year
LPT Jind OK Def. (Soft + ICs) Nil Nil
1.7 ELECTRIC CONNECTION DETAILS
Name of Station
Availability of Electricity
Whether Single Phase / Three Phase
Sanctioned Load
Power Factor
Karnal Available Co-sited with HPT Karnal (3 Phase) 150 KVA 0.97
Kurukshetra Available Co-sited with AIR Kurukshetra (3 Phase) - -
Ambala Available (3 Phase) 25.8 KW 0.89
Yamunanagar Available (3 Phase) 18.3 KW Better than 0.85
Jind Available (3 Phase) 7.8K W -
Kaithal Available (3 Phase) 24.7 KW -
1.8 LAND / BUILDING DETAILS
Station Name of Owner of Land
Category of Owner
(Deptt. / Govt. / Private)
Type of Building
(Porta Cabin / Permanent)
Is Building / Porta Cabin constructed
departmentally
Rent of Setup
(Rs. p.m.)
Availability of Lease
Deed
Due Date of Renewal of Lease Deed
Due Date of Revision of
Rent Remarks
Karnal Prasar Bharati Deptt Permanent Yes - LPT in HPT Building -
Kurukshetra Govt. Of India Deptt Porta Cabin Yes - LPT in AIR Campus ( own Porta-Cabin) -
Ambala State Govt. State Govt. Permanent No No Rent - - - -
Yamunanagar Improvement Trust. State Govt. Permanent No 5625/- - 30.04.2013 1.05.2013
Jind Govt. of India Deptt. Permanent Yes - - - - -
Kaithal HS MITC State Govt. Permanent No 8840/- 04.08.2013 08.2013 Rent as per DC Kaithal-
2. TECHNICAL
2.1 DETAILS OF WORKING OF TRANSMITTER FOR THE MONTH June 2011
LPT
Karnal LPT
Kuruksh.LPT
Ambala LPT
Y. Nagar LPT Jind
LPT Kaithal
1 Test Hours 7.50Hrs 10.00 Hrs 15.00 Hrs 10.00Hrs 4.00 Hrs. 7.50 Hrs
2 Scheduled Prog. Hours 570.00 570.00 570.00 570.00 573.91 227.38
3 Gear Breakdown Hrs. Nil 0.00 0.00 0.00 Nil 0.00
4 Power Supply Breakdown Hrs. 0.53 0.00 1.17 0.00 0.78 0.30
5 Other Causes Breakdown Hrs. Nil 0.00 0.06 0.00 Nil 0.00
6 Total Breakdown Hrs. (3+4+5) 0.53 0.00 1.23 0.00 0.78 0.30
7 Prog. Hours Radiated (2-6) 569.47 570.00 568.77 570.00 573.13 227.08
8 Total Hours of Working (1+7) 576.97 580.00 583.77 580.00 577.13 234.58
9 % B/D ={(Total B/D x 100)/ Scheduled Prog. Hrs.)} 0.09 % 0.00 0.21% 0.00 0.135% 0.13%
2.2 PROGRESSIVE TOTAL FROM APRIL OF CURRENT FINANCIAL YEAR
LPT
Karnal LPT
Kuruksh. LPT
Ambala LPT
Y. Nagar LPT Jind
LPT Kaithal
1 Test Hours 22.75 30.33 45.50 30.33 12.26 22.75
2 Scheduled Prog. Hours 1729.00 1729.00 1729.00 1729.00 1718.74 666.02
3 Gear Breakdown Hrs. Nil 0.00 0.00 0.00 Nil 0.00
4 Power Supply Breakdown Hrs. 1.54 0.00 2.57 0.00 2.8 1.15
5 Other Causes Breakdown Hrs. Nil 0.00 0.06 0.00 Nil 0.00
6 Total Breakdown Hrs. (3+4+5) 1.54 0.00 2.63 0.00 2.8 1.15
7 Prog. Hours Radiated (2-6) 1727.46 1729.00 1726.37 1729.00 1715.94 664.87
8 Total Hours of Working (1+7) 1750.21 1759.33 1771.87 1759.33 1728.2 687.62
9 % B/D ={(Total B/D x 100)/ Scheduled Prog. Hrs.)} 0.09 % 0.00 0.15 0.00 0.16 % 0.17%
2.3 DETAILS OF POWER OF TRANSMITTER FOR THE MONTH June 2011 LPT
Karnal LPT
Ku-kshetraLPT
Ambala LPT
Y. Nagar LPT Jind
LPT Kaithal
1 Rated Power of Transmitter (in KW / Watts) 300 500 500 300 100 500
2
Forward Peak Power of Transmitter
Video 300 500 498 170 Aver. 100
Audio 30 30 - 30 10
3
Reflected Power
Video 3.0 <1.00 2.0 2.0 10.00 2.00
Audio - - - - -
4 Since when Transmitter is on less than rated power (if applicable)
- - - - -
5 Reasons for less than rated power - - - - -
6 Reasons for high reflection, if any - - - - - -
2.4 DETAILS OF LOW POWER RADIATION FROM TRANSMITTER June 2011 (Sync Peak Video Power less than rated power)
LPT
Karnal LPT
Kuruksh. LPT
Ambala LPT
Y. Nagar LPT Jind
LPT Kaithal
1 Dates - - - - - -
2 Duration - - - - - -
3 Power (Radiation) - - - - - -
4 Reasons - - - - - -
5 Total duration of Low Power in hours during the month
6 No. of occurrences - - - - - -
7 Progressive total of occurrences of Low Power Radiation - - - - - -
8 Progressive total of duration of Low Power Radiation - - - - - -
9 Complaints of reception, if any & Reason of complaints - - - - - -
DETAILS OF MAJOR BREAKDOWN DURING THE MONTH June 2011
(More than 15 minutes)
LPT Karnal (separate for each LPT)
Date Duration Period Reasons
for B/D Action taken to solve the B/D
Preventive action taken to avoid such
breakdown in future From To
- - - - - - -
LPT Kurukshetra (separate for each LPT)
Date Duration Period Reasons
for B/D Action taken to solve the B/D
Preventive action taken to avoid such
breakdown in future From To
- - - - - - -
LPT Ambala (separate for each LPT)
Date Duration Period Reasons
for B/D Action taken to solve the B/D
Preventive action taken to avoid such
breakdown in future From To
- - - - - - -
LPT Yamunanagar (separate for each LPT)
Date Duration Period Reasons
for B/D Action taken to solve the B/D
Preventive action taken to avoid such
breakdown in future From To
- - - - - - -
LPT Jind (separate for each LPT)
Date Duration Period Reasons
for B/D Action taken to solve the B/D
Preventive action taken to avoid such
breakdown in future From To
- - - - - - -
LPT Kaithal (separate for each LPT)
Date Duration Period Reasons
for B/D Action taken to solve the B/D
Preventive action taken to avoid such
breakdown in future From To
- - - - - - -
CATEGORY WISE BREAKDOWN DURING THE MONTH June 2011 2.5
LPT Karnal (separate for each LPT) GEAR POWER SUPPLY OTHER CAUSES
Major Minor Major Minor Major Minor No. Dur. No. Dur. No. Dur. No. Dur. No. Dur. No. Dur.
- - - - - - 32 0.53 - - - - Remarks: MI (PS) : 32nos LPT Kurukshetra (separate for each LPT)
GEAR POWER SUPPLY OTHER CAUSES Major Minor Major Minor Major Minor
No. Dur. No. Dur. No. Dur. No. Dur. No. Dur. No. Dur. - - - - - - - - - - - -
Remarks: MI (PS) : 27 nos.
LPT Ambala (separate for each LPT) GEAR POWER SUPPLY OTHER CAUSES
Major Minor Major Minor Major Minor No. Dur. No. Dur. No. Dur. No. Dur. No. Dur. No. Dur.
- - - - - - 35 1.17 - - 1 0.06 LPT Yamunanagar (separate for each LPT)
GEAR POWER SUPPLY OTHER CAUSES Major Minor Major Minor Major Minor
No. Dur. No. Dur. No. Dur. No. Dur. No. Dur. No. Dur. - - - - - - - - -
Remarks: MI (PS) : 21nos
LPT Jind (separate for each LPT) GEAR POWER SUPPLY OTHER CAUSES
Major Minor Major Minor Major Minor No. Dur. No. Dur. No. Dur. No. Dur. No. Dur. No. Dur.
- - - - - - 47 0.78. - - -
LPT Kaithal (separate for each LPT) GEAR POWER SUPPLY OTHER CAUSES
Major Minor Major Minor Major Minor No. Dur. No. Dur. No. Dur. No. Dur. No. Dur. No. Dur.
- - - - - - 18 0.30 - - - -
2.6 CATEGORY-WISE PROGRESSIVE BREAKDOWN FROM APRIL OF CURRENT FINANCIAL YEAR
LPT Karnal (separate for each LPT) GEAR POWER SUPPLY OTHER CAUSES
Major Minor Major Minor Major Minor No. Dur. No. Dur. No. Dur. No. Dur. No. Dur. No. Dur.
- - - - - - 93 1.54 - - - - Remarks: MI (PS) : 93nos LPT Kurukshetra (separate for each LPT)
GEAR POWER SUPPLY OTHER CAUSES Major Minor Major Minor Major Minor
No. Dur. No. Dur. No. Dur. No. Dur. No. Dur. No. Dur. - - - - - - - - - - - -
Remarks: MI (PS) : 106
LPT Ambala (separate for each LPT) GEAR POWER SUPPLY OTHER CAUSES
Major Minor Major Minor Major Minor No. Dur. No. Dur. No. Dur. No. Dur. No. Dur. No. Dur.
- - - - - - 77 2.57 1 0.06 LPT Yamunanagar (separate for each LPT)
GEAR POWER SUPPLY OTHER CAUSES Major Minor Major Minor Major Minor
No. Dur. No. Dur. No. Dur. No. Dur. No. Dur. No. Dur. - - - - 6KVA UPS in CKT. - - - -
Remarks: MI (PS) : 30 nos
LPT Jind (separate for each LPT) GEAR POWER SUPPLY OTHER CAUSES
Major Minor Major Minor Major Minor No. Dur. No. Dur. No. Dur. No. Dur. No. Dur. No. Dur.
- - - - - - 168 Nos.
2.8 Hrs. - - - -
LPT Kaithal (separate for each LPT) GEAR POWER SUPPLY OTHER CAUSES
Major Minor Major Minor Major Minor No. Dur. No. Dur. No. Dur. No. Dur. No. Dur. No. Dur.
- - - - - - 69 1.15 - - - -
2.7 PERFORMANCE FIGURES OF TRANSMITTER LPT
Karnal LPT
Kuruksh.LPT
Ambala LPT
Y. NagarLPT Jind
LPT Kaithal
Frequency of Vision Carrier 559. 260416 543.260416 575.260416 519. 260416 217.25 543.25
Frequency of Aural Carrier 564. 760416 548.760416 580.760416 524.260416 222.75 548.75
K Factor Meas. Equp. Not Availble
Meas. Equp. Not
Available
Meas. Equp. Not
Available
Meas. Equp. Not
Available
(1) K-Bar
(2) K Pulse to Bar
(3) K2T
Differential Gain
Differential Phase
Signal to Noise Ratio
Vision Peak Power
2.8 VIDEO FREQUENCY RESPONSE
Station Freq (MHz) -1.25 -0.75 0.0 1.0 1.5 2.0 3.0 4.43 5.0 5.30 5.50
Karnal
Kurukshetra
Ambala
Yamunanagar
Jind
Kaithal Note: Gain in dB
2.9 AUDIO PERFORMANCE FIGURES
LPT
Karnal LPT
Kuruksh.LPT
Ambala LPT
Y. NagarLPT Jind
LPT Kaithal
Aural Carrier 564. 760416 548.760416 580.760416 524.260416 222.75 548.75
Frequency response
50 Hz to 15 KHz
Distortion Factor
F.M. Noise level
Frequency Deviation at
100% Modulation
2.10 WORKING STATUS OF 500W AUTO MODE TRANSMITTERS
(Wherever applicable) S.No. Name of LPT Xtr. Make, Model,
Channel Whether
Operating on Auto / Manual Mode
Details of Fault
occurred
Current Working Status
(in detail)
Remarks
------ NA -----
2.11 WORKING STATUS OF VLPTs (Wherever applicable) Sr. No.
Name of VLPT
Ch. No.
Type of Transmitter
Rated Power
O/P Power
Reflected Power
Ex-1
Ex-2
PA1 PA2 ASU
------ NA -----
Sr. No.
Name of VLPT
Batteries (In circuit)
Solar Panel Battery Charger
Charge Controller
Installed Damaged Remark Installed Damaged Remark
------ NA -----
2.12 EARTH RESISTANCE (in Ohms)
Station TX EARTH
PS EARTH DG Set PDA-1 PDA-2 TOWER
Date of measure-
ment
Make, Model and type of Instrument used for
measurement
Karnal 1.60 0.80 0.9 1.2 1.0 0.9 17.04.2011 Motwane
Kurukshetra 0.56 0.75 0.76 0.78 0.60 0.41 24-06-2011 Waco Digital Earth Resistance Meter
Ambala 0.42 0.40 0.62 0.51 0.50 0.58 20.06.2011 Waco Digital ERM
Yamunanagar 1.0 0.2 1.6 1.8 1.7 1.6 06.06.2011 Motwane DET-20
Jind 1.3 1.4 1.8 1.1 1.0 1.8 19.04.2011 Digital Make WACO
Kaithal 0.35 0.36 0.42 0.71 0.78 0.35 26.06.11 Waco Digital ERM
3. REQUIPMENTS & SPARES
3.1 REQUIREMENT OF SPARE COMPONENTS Station Name of
Component Part No.
Name of Unit of
transmitter for which required
Quantity Required
Qty available
at Station
Qty issued to Station during last six months
Justification for
requirement
Karnal (separate for each LPT)
Ku.Kshetra (separate for each LPT)
Ambala (separate for each LPT)
Ch. Filter - XTR 01 Nil Nil
Pine apple board - 300W PA 01 Nil Nil
RF Card(FEC) - Scopus IRD 02 Nil Nil
Y. Nagar (separate for each LPT)
Jind (separate for each LPT)
SCR 3890 28V/25A PS - 02 01 As spare 10000 Mfd. /63V DC Capacitor -do- 06 - - -
Capacitor 45 mfd 440 volt For A.C. 02 Nos. Nil
Kaithal (separate for each LPT)
- - - - - -
LPT (separate for each LPT) -
- - - - - -
- - - - - - -
3.2 REQUIREMENT OF SPARE EQUIPMENTS / CARDS / MODULES
Station Name of
Equipment / Card / Module
Part No.
Name of Unit of
transmitter for which required
Quantity Required
Qty available
at Station
Qty issued
to Station during last six months
Justification for
requirement
Karnal (separate for each LPT)
- - - - - - -
Ku.Kshetra (separate for each LPT)
High low cut Tirpping device contact capacity 25 A
Mains 01 - - Supply
Variable DC Regu 0-30 V,10A
- - - - Repair work
Up converter ch 30+ GA110600621812 Exciter unit 01 Stand by
Ambala (separate for each LPT)
Y. Nagar (separate for each LPT)
TV reciever 02 Monitoring 28V 50A SMPS 04
3 db combiner Combiner Unit 01 Spare combiner from LPT Karnal in Circuit
Jind (separate for each LPT)
CRO - 01 - - For measurement
WFM - 01 - For measurement
A/V Switcher 8X2 - 01 02 - 02 def.-
Kaithal (separate for each LPT)
3.3 AVAILABILITY OF SPARE -- COMPONENTS / MODULES /
TRANSMITTER UNITS
Spare Components Station Name of Spare
Component Qty. in Stock Working Status
LPT Karnal (separate for each LPT)
UTV 200 01 O.K.
LPT Ku. Kshetra UTV 200 01 O.K. LPT Ambala - - - LPT Y. Nagar UTV 200 05 O.K.
BLW-98 05 O.K. BLW-32,33 06 each O.K.
LPT Jind
UTV 150 02 O.K. UTV 300 01 O.K.
UMIL 100 04 O.K. LPT Kaithal
15V Reg., AGC, APL, Control board, Hybrid Amp. 1No. Each O.K.
PCB of TPV 8100 B 01 O.K. TPV 595A 02 0.k PCB of TPV 595 with bias 02 Nos. O.K.
Spare Transmitter Modules
Station Name of Spare
Transmitter Modules (pallets)
Qty. in stock Working Status
Karnal (separate for each LPT)
Ku. Kshetra - - -
Ambala
Y. Nagar -
Jind Modulator of Ch#11 (Commercial Type) 01 OK
Kaithal PA Ch#29 Ch#34 01- -ok
33/26 V SMPS Digitronics 01 ok
spare Transmitter Units
Station Name of Spare Transmitter Unit
Qty. in Stock
Working Status
LPT Karnal (separate for each LPT)
50 W PA 02 One No. is low power due to weak biasing Transistors & UTV200
28V/50A SMPS 01 O.K
LPT Ku. Kshetra
300 Watt PA Make : GCEL 02 (Stand By) One Faulty, one O.K.
SMPS 28V/40A : GCEL
02 (Stand By)
Both working O.K.
LPT Ambala
28V/40A SMPS 01 O.K
LPT Y. Nagar
50 W PA 02 Low Power - - -
LPT Jind
28V/25A PS 01 OK Power Amp. 02 OK 12-25 W Driver Amp. 01 OK
LPT Kaithal 33V/26V (SMPS) 01 OK
PA Ch 29/Ch 34 01 OK
3.4 DETAILS OF DEFECTIVE TRANSMITTER EQUIPMENT
Make & Model of Transmitter
Name of defective Tx equipment
Since when it
is defective
Action taken by Station for
the repair
Shortcoming if any, being
faced by station for the repair
Remarks
300 W GCEL LPT Karnal
- - - - - - - - - -
500 W GCEL-12U-500
LPT Kurukshetra
300 W Power Amplifier Dec. 2009
UHF 200-AB AMPLIFIER One Pallet is Defective
Parts not available in DMC
500 W GCEL-12U-500
LPT Ambala
DP corrector 25.03.08 Deffective
PA Pine apple board 1.08.06 Deffective
GCEL 121 III 100 w Jind
Exciter & Audio vedio switcher 3/2007
300 W GCEL LPT Yamuna
Nagar SMPS 28V/50A, 03 nos Sep 09,
0ne under repair In one PCB burnt 01 beyond repair
Power Amplifier 50 w Feb 10 0ne under repair
3.5 WORKING STATUS OF AVR FOR TRANSMITTER
Station Capacity of
AVR Make and
Type Working Condition ( Auto/Manual/def)
Action Taken for repair, if defective
Karnal 10KVA True Line Auto - Kurukshetra 10 KVA Sylvan, 3VS OK (Auto) (Line Noise
Suppressor Faulty)It is sealed unit. Matter has been taken up with company to supply a new one.
Ambala 10 KVA GCEL 3VS OK (Auto) Y. Nagar 10 KVA Sylvan, 3VS OK (Auto) Jind 10 KVA CYBEX, 3VS OK (Auto) Kaithal 10 KVA Aplab make OK
3.6 WORKING STATUS OF DIESEL / PETROL / KEROSENE GENERATOR SETS AT LPTs / VLPTs
Station Capacity of
Generator Make, Model
and Type Working Condition
Action Taken for
repair, if defective LPT Y. Nagar 15KVA HA 294
Kirloskar Overhauling
required- -
Kurukshetra 15KVA HA 294 Kirloskar ok
Ambala 15KVA Kirloskar ok
Karnal 125 KVA Greaves ok
Kaithal 15KVA HA 294 Kirloskar ok
Jind 15KVA HA 294 Kirloskar ok
3.7 TVRO ELECTRONICS
Station Make & Type of
IRDs Total No.
available
Total No. Defective
Action taken by Station for
repair
Remarks
LPT Karnal
Scopus DVB IRD-2800 1 No. -Def Under progress - Scopus DVB IRD-2900 1 no Sky 21 DVB (Mini Sat) 1 No. - - -
Thomson DSR 200T 1 No. - - - MXI ADI IRD 1 No. -Def - Under progress -
LPT Kurukshetra
Scopus DVB IRD-2800 Two nos. 01 Capacitor 150 micro farad/400 V in P.S. Card is faulty
Sky 21 DVB (Mini Sat) 1 No. 1 No Def Under progress - Changhong 1 No. Delton 1 No.
LPT Ambala
Scopus DVB IRD-2800 2 Nos. Only one FEC in each working.
Thomson DSR 200T 1 No. Def. RF section def. Echo Star 2150 R 1 No. Def. PS Board Changhong 1 No. Delton 1 No.
LPT Yamuna-nagar
Scopus DVB IRD-2800 1 Nos. - - - Scopus DVB IRD-2900 1 no DTH Receiver Power 1 No.
Changhong 1 No. Def. - -
l Delton plus PS005 1No. -. -
LPT Jind
Thomson DSR 200T *2 No. 01 No. Def. - One on loan from HPT KNL
Sky 21 DVB (Mini Sat) 1 No. - - Changhong 1 No. - - - Delton 1 No. Scopus DVB IRD-2800 2 Nos. -02 ok - -
LPT Kaithal
Euro Star IRD 1 No. Def. Software problem - MXI ADI IRD 1 No. - - -
Changhong 1 No. - - - Scopus DVB IRD-2800 1 Nos. - - -
3.8 UPS
Station Make, Model & Rating of UPS
Total No.available
Total No. Defective
Action taken by Station for
repair Remarks
LPT Yamunanagar
Aplab 6 KVA 01
Defective Batteries 20
Nos Require
replacement
LPT Kurukshtra
Elnova X500 W 02 ONE Not repairable in local Mkt. For Telemetry
APC 650 VA 01 01 Battery has been worn out For PC
LPT Jind 0.5 KVA Line Iteractive Made APA 01 Nil For scroll bar
3.9 AIRCONDITIONERS & AVRs
Station Total No. at Station
Defective Nos.
Make and Model of defective
Date from
which def.
Reason for Being
defective
Action taken by Station for the repair
Karnal
Air- conditioner 03 Nos. - - - -
AVRs for ACs 03 Nos. - - - -
Kurukshetra
Air- conditioner 04 Nos. 01 No.
Videocon Sr. No. 51254
One of the terminal on compressor has been melt down.
Can not repair locally
AVRs for ACs 07 Nos. - - - -
Ambala
Air- conditioner 05Nos. - -
Sl. No. 7575 7579&7580 Cooling efficiency very low.
AVRs for ACs 05 Nos. - - -
Y. Nagar Air- conditioner 05 Nos. 01
01 Samsung as declared
unserviceable by Samsung
service dealer
19.05.11 Gas leekage
03 Blue star low cooling VIVA make OK
AVRs for ACs 03 Nos. - - -
Jind
Air- conditioner 06 Nos. 4 Nos. 1.5 T
carrier 4 years Aging effect.
AVRs for ACs 05 Nos. 1 No. Sent to DMC
Hissar
Kaithal
Air- conditioner 03 Nos. - - -
AVRs for ACs 03 Nos. - - -
3.10 DETAILS OF DEFECTIVE INPUT / MONITORING AND MEASURING EQUIPMENTS
Station Name of defective equipment
Make and model of defective
equipment
Date from which
defective
Action taken by Station for the repairing
Karnal Earth Resistance Meter (Analog)
Waco Spindle detached from pivot, Unit is sealed.
Kurukshetra
1 Colour Monitor 2 Telemetry System
BEL old model-2Nos. Prototype model of R&D (AIR/DD)
-Received defective from I.O. in Nov, 2001 - March, 2008
-Not repairable -Since no literature is available at the Station. Matter has been taken up with CE (R&D) for repair.
Ambala
Echo Star IRD Thomson TV Set 20” Phillips
DSB 1100 DSB 200T Phillips 27000220
- -
21.09.09
-PS Board def. -RF Section def. -STR PLVC 802 P was changed but did not work.
Yamuna-nagar
Colour TV Set 21” Colour TV Set 14’’ Sony monitors 02 nos
ECTV (2 Nos.) one def & in other reception poor Uptron Sony, Trintron
Very old (obsolete)
PCB faulty 01Def & one with color problem in picture quality
-.
Jind CRO WFM Digital M. Meter
Tekhind, 2235 Tektronix, 1731 Phillips
Aging effect. (poor response)
Kaithal
-Euro Star (DVB) O Euro Plus Software problem
3.11 WORKING FIGURES OF DIESEL GENERATORS June 2011
For LPTs only
Karnal Ku. kshetra Ambala Y.
Nagar Jind Kaithal
Make
LPT
inst
alle
d in
HP
T H
all
HA-294 Kirloskar
HA-294 Kirloskar
HA-294 Kirloskar
Kirloskar HA – 294
HA-294 Kirloskar
Capacity 15 KVA 15 KVA 15 KVA 15 KVA 15 KVA Utilization for transmission during the month 20.07 Hrs 22.37 16.80 54.12 16.83
Test Hrs. for the month ------ Hrs 11.83 3.0 2.08 4.50
Total Working Hrs. for the month 20.07 Hrs 34.20 19.80 56.20 21.33
Progressive utilization 80.22 Hrs 83.80 76.30 175.84 72.15 Occasion of utilization during the month 27 35 51 59 18
Progressive Utilization 106 77 175 193 98 Breakdown in service due to failure of D/G during the month
Nil Nil Nil Nil
Nil
Average consumption of Diesel (Lit/Hr.) 1.89 lt/hr. 2.04 2.47 2.02 2.25
Date of commissioning of DG set
17th Nov 2001 16.11.01 22.05.00
Received from LPT KNL on
23.01.2008
05.09.05
Total Hours of working since date of commissioning 5396.43 6878.41 7350.80 6080.18 2053.05
Reading of Hour Meter installed at DG Set at the end of month
Not in circuit Def. Def
Defective -
Reading of Hour Meter installed at LT Panel at the end of month
5343.5 hrs667.0
(start from zero on
16.02.10
def 41720.0
Def
4. CABLE OPERATORS MONITORING REPORT June 2011
MONITORING REPORT FOR THE IMPLEMENTATION OF CABLE TV
NETWORK REQULATION
. No.
Stat
e &
nam
e of
M
onito
ring
st
atio
n
Nam
e A
nd
Add
ress
of
MSO
s
DD CHANNELS TO BE CARRIED ON CABLE NETWORK
Prime Band Channels Non Prime Band Channels
DD
-N
atio
nal
DD
-N
ews
DD
-R
egio
nal
/ B
hara
ti
DD
-Sp
orts
DD
-LS
DD
-RS
DD
-U
rdu
Gya
n D
arsh
an DD
Bha
rati
(If
1 LPT Karnal Seven Star Cable Network, Karnal 10 06 38 266
Mhz- - - - -
2 LPT Kuru Kurukshetra Darpan Pvt. Ltd. SCO 77 Ist Floor Sector-13 Kurukshetra 09 01 02 29 46 47 - 48
3 LPT Ambala
M/s Ambala Cable Network, H.No – 810, Sector-7, Ambala City. 09 02 - - - - - -
M/S Ganpati Cable Network Ambala City. 06 03 - - - - - -
M/s Radhe Cable Network, Ambala Cantt. 06 03 - - - - - -
4 LPT Y.Nagar Den SAYA Cable Network Yamunanagar 03 06 12 34 - 35 - -
5
1. 2.
Jind Cable Network Saphidho Gate, Jind 2 4 12 S20 - C22 C28 C12
Star Cable Network, Jind 04 02 06 10 - S2 16 06
6 LPT Kaithal
M/s Kaithal Cable Network, Ambala Road, Kaithal Yes Yes Yes Yes - No No No M/s Friends Cable Network, Devigarh Rd., Kaithal Yes Yes Yes Yes - No No No
1. State wise report is to be compiled. All monitoring stations under the same state should come together. Cities and major locations need to be reported. 2. Statement “YES” or “NO” is to be mentioned against each channel both in prime and non prime band. 3. Action taken like reporting to DM/SP/any other law enforcing authority is to be mentioned’ in Remarks column 4. Copy of complaint as lodged should be forwarded to the Satellite Maintenance Dte. of DG DD