+ All Categories
Home > Documents > DORIS MCLEOD AIR QUALITY PLANNER VIRGINIA DEQ 804/698-4197 [email protected] ERTAC Tool...

DORIS MCLEOD AIR QUALITY PLANNER VIRGINIA DEQ 804/698-4197 [email protected] ERTAC Tool...

Date post: 03-Jan-2016
Category:
Upload: theresa-hancock
View: 213 times
Download: 0 times
Share this document with a friend
Popular Tags:
18
DORIS MCLEOD AIR QUALITY PLANNER VIRGINIA DEQ 804/698-4197 [email protected] ERTAC Tool Logic and Flowcharts
Transcript
Page 1: DORIS MCLEOD AIR QUALITY PLANNER VIRGINIA DEQ 804/698-4197 doris.mcleod@deq.virginia.gov ERTAC Tool Logic and Flowcharts.

DORIS MCLEODAIR QUALITY PLANNER

VIRGINIA DEQ804/698-4197

dor i s [email protected] i rg in ia .gov

ERTAC Tool Logic and Flowcharts

Page 2: DORIS MCLEOD AIR QUALITY PLANNER VIRGINIA DEQ 804/698-4197 doris.mcleod@deq.virginia.gov ERTAC Tool Logic and Flowcharts.

PRESENTATION OVERVIEW

Preprocessor Functions Data QA Data manipulations Calculations

Projection Processor Functions Generation calculations Generation deficit units defined, if needed Excess power redistribution-Two step process Outputs

Post ProcessorsQuestions?

2

Page 3: DORIS MCLEOD AIR QUALITY PLANNER VIRGINIA DEQ 804/698-4197 doris.mcleod@deq.virginia.gov ERTAC Tool Logic and Flowcharts.

Preprocessor Functions

Need for preprocessingPreprocessing allows improved projection

outputsBasic functions:

Hourly CAMD data update to remove non-EGUs Examine data outliers Sets up base year (BY) structure Examines input files

3

Page 4: DORIS MCLEOD AIR QUALITY PLANNER VIRGINIA DEQ 804/698-4197 doris.mcleod@deq.virginia.gov ERTAC Tool Logic and Flowcharts.

Preprocessor

Creates a preprocessor log file Important for QA Improves input

files

Files from the preprocessor are fed to the processor

4

Page 5: DORIS MCLEOD AIR QUALITY PLANNER VIRGINIA DEQ 804/698-4197 doris.mcleod@deq.virginia.gov ERTAC Tool Logic and Flowcharts.

Projection Processor, Part 1

Calculates future generation By region and fuel/unit type Outputs are modular

Capacity deficit check May generate generation deficit units Treated as new units, with profiles

Grows all existing units based on hourly growth rates

Determines if there is excess generation in any hour

5

Page 6: DORIS MCLEOD AIR QUALITY PLANNER VIRGINIA DEQ 804/698-4197 doris.mcleod@deq.virginia.gov ERTAC Tool Logic and Flowcharts.

Capacity check GDUs May require

recalculation

Grow existing units for each hour of the year

Creation of Excess Generation Pool (ExGen)

Projection Processor, Part 1

6

Page 7: DORIS MCLEOD AIR QUALITY PLANNER VIRGINIA DEQ 804/698-4197 doris.mcleod@deq.virginia.gov ERTAC Tool Logic and Flowcharts.

Distributes ExGenTwo step

distribution Optimal threshold Maximum

thresholdActivity for a unit

depends on Growth rates, New units, Retired units, Capacity

constraints on other existing units

Projection Processor, Part 2

7

Page 8: DORIS MCLEOD AIR QUALITY PLANNER VIRGINIA DEQ 804/698-4197 doris.mcleod@deq.virginia.gov ERTAC Tool Logic and Flowcharts.

Spinning reserve check

Additional capacity available up to 100% of largest unit on line

Sends up a red flag if reserve requirements are not met

Projection Processor, Part 4

8

Page 9: DORIS MCLEOD AIR QUALITY PLANNER VIRGINIA DEQ 804/698-4197 doris.mcleod@deq.virginia.gov ERTAC Tool Logic and Flowcharts.

Calculates emissions

Compares state and regional emissions against supplied caps

Sends up a red flag caps are not met

Does not currently assign tool-generated controls to ensure caps are met

Projection Processor, Part 5

X

9

Page 10: DORIS MCLEOD AIR QUALITY PLANNER VIRGINIA DEQ 804/698-4197 doris.mcleod@deq.virginia.gov ERTAC Tool Logic and Flowcharts.

Projection Processor Notes

Future year (FY) activity is firmly grounded in BY meteorology

Many FY estimates may be adjusted by region and fuel unit type bin in the input_variables

NonCAMD units may be included IF: Hourly BY activity data in a CAMD-like format exists AEO/NERC growth rates are applicable to the unit

Creates a processor log file Output files are quite large (hourly data):

3,000-4,000 units, most with 8,760 hours of data; Input and output files each several gigabytes

10

Page 11: DORIS MCLEOD AIR QUALITY PLANNER VIRGINIA DEQ 804/698-4197 doris.mcleod@deq.virginia.gov ERTAC Tool Logic and Flowcharts.

Post Processors

Several have been developed

Aids in data review and trouble shooting

Output files are large, but can be manipulated in very interesting ways

11

Page 12: DORIS MCLEOD AIR QUALITY PLANNER VIRGINIA DEQ 804/698-4197 doris.mcleod@deq.virginia.gov ERTAC Tool Logic and Flowcharts.

Graphical Post Processor

12

Page 13: DORIS MCLEOD AIR QUALITY PLANNER VIRGINIA DEQ 804/698-4197 doris.mcleod@deq.virginia.gov ERTAC Tool Logic and Flowcharts.

Graphical Post Processor

13

Page 14: DORIS MCLEOD AIR QUALITY PLANNER VIRGINIA DEQ 804/698-4197 doris.mcleod@deq.virginia.gov ERTAC Tool Logic and Flowcharts.

ORIS/Unit IDFacility Name, State,

RegionFuel/Unit TypeActivity Data

Annually and OSEmissions Data

NOx, SO2 Annually and OS

Other data Lat/longs Retirement dates

May be used for QA

Can be manipulated into charts and spreadsheets

Compared with inventory estimates

Enhanced Unit Activity File

14

Page 15: DORIS MCLEOD AIR QUALITY PLANNER VIRGINIA DEQ 804/698-4197 doris.mcleod@deq.virginia.gov ERTAC Tool Logic and Flowcharts.

Pivot Table Options

15

BY vs FY Generation

Page 16: DORIS MCLEOD AIR QUALITY PLANNER VIRGINIA DEQ 804/698-4197 doris.mcleod@deq.virginia.gov ERTAC Tool Logic and Flowcharts.

Pivot Table Options, Facility Level

16

BY vs FY Annual NOx Emissions

Page 17: DORIS MCLEOD AIR QUALITY PLANNER VIRGINIA DEQ 804/698-4197 doris.mcleod@deq.virginia.gov ERTAC Tool Logic and Flowcharts.

Pivot Table Options, Unit Level

17

BY vs FY Annual NOx Emissions

Page 18: DORIS MCLEOD AIR QUALITY PLANNER VIRGINIA DEQ 804/698-4197 doris.mcleod@deq.virginia.gov ERTAC Tool Logic and Flowcharts.

DORIS MCLEODAIR QUALITY PLANNER

VIRGINIA DEQ804/698-4197

dor i s [email protected] i rg in ia .gov

Questions? Comments? Thoughts?

18


Recommended