2
DOUBLE PIPE HEAT EXCHANGER DK 236 The setup consists of Double Pipe Heat Exchanger with Hot water tank fitted with Pump, Rotameter and Immersion Heater to heat the water. While the cold liquid tank fitted with Pump and Rotameter. The temperature of the heated liquid measured by the thermocouple is displayed on Digital Temperature Indicator. The exit temperature of hot water and entry and exit temperatures of cold liquid are also measured with the help thermocouple and indicated on Digital Temperature Indicator. The Unit is also having necessary piping and valve arrangements. Heat Exchanger: Inner Tube: MOC : SS 304 Dimensions : 25 mm (D) * 750 (L) mm Outer Tube: MOC : SS 304 Dimensions : 75 (D) f * 750 (L) mm Insulation : 25 mm thick glass wool with SS 304 sheet cover Hot Water Tank: Inner MOC : SS 304 Outer MOC : MS with powder coating Capacity : 30 liters Heater : 1 kW rating Temp. Control : Thermostatic Type Insulation : 25 mm glass wool
Transcript
Page 1: DOUBLE PIPE HEAT EXCHANGER fileDOUBLE PIPE HEAT EXCHANGER DK 236 The setup consists of Double Pipe Heat Exchanger with Hot water tank fitted with Pump, Rotameter and Immersion Heater

DOUBLE PIPE HEAT EXCHANGER

DK 236

The setup consists of Double Pipe Heat Exchanger with Hot water tank fitted with Pump, Rotameter and Immersion Heater to heat the water. While the cold liquid tank fitted with Pump and Rotameter. The temperature of the heated liquid measured by the thermocouple is displayed on Digital Temperature Indicator. The exit temperature of hot water and entry and exit temperatures of cold liquid are also measured with the help thermocouple and indicated on Digital Temperature Indicator. The Unit is also having necessary piping and valve arrangements. Heat Exchanger:

Inner Tube: MOC : SS 304 Dimensions : 25 mm (D) * 750 (L) mm Outer Tube: MOC : SS 304 Dimensions : 75 (D) f * 750 (L) mm Insulation : 25 mm thick glass wool with SS 304 sheet cover

Hot Water Tank: Inner MOC : SS 304

Outer MOC : MS with powder coating Capacity : 30 liters

Heater : 1 kW rating Temp. Control : Thermostatic Type Insulation : 25 mm glass wool

Page 2: DOUBLE PIPE HEAT EXCHANGER fileDOUBLE PIPE HEAT EXCHANGER DK 236 The setup consists of Double Pipe Heat Exchanger with Hot water tank fitted with Pump, Rotameter and Immersion Heater

DK 236Cold Water Tank: MOC : SS 304 Capacity : 30 liters With ½” drain valve Hot Water Pump:

Type : Monoblock MOC : CI body Power : 0.25 HP

Cold Water Pump: Type : Monoblock MOC : CI body Power : 0.25 HP

Rotameter: Quantity : 2 nos. Range : 1 - 10 LPM Glass Tube : Borosilicate Float : pre-calibrated, SS 316 Valve : Integral Needle type

Temperature Measurement: Thermocouple : 4 Nos. Type : “PT-100” Indicator : Digital Temperature Indicator (Range: 0-199.9 °C) Control Panel:

· Mains · On/ Off/Rocker Switches for Heaters · On/ Off/Rocker Switches for Water Pump and Hot Water Pump · Digital Temperature Indicator with Selector Switch (‘8’ Zone)

The set up is mounted on a suitable MS frame Structure with attractive colour and control panel of good powder coating. The equipment is self sufficient type including all necessary piping and valves and does not required any more foundation. The detail operating manual is provided with the setup.

PARALLEL/COUNTER FLOW HEAT EXCHANGERDOUBLE PIPE HEAT EXCHANGER