7th Annual Sucker Rod Pumping Workshop
Renaissance Hotel Oklahoma City, Oklahoma
September 27 - 30, 2011
Downhole Diverter Gas Separator
Ken Skinner, Lynn Rowlan, Dieter Becker - Echometer Company A. L. Podio - University of Texas - Austin
Jim McCoy
liquid in anchor
pump
slip
gas in anchor
Basic Principles of Downhole Separator
System Gravity separation is the
governing principle for downhole gas separators.
2
GAS BUBBLES FLOW UPWARD IN OIL OR WATER AT A RATE OF APPROXIMATELY 6 INCHES PER SECOND. THUS, GAS BUBBLES WILL BE RELEASED FROM A LIQUID COLUMN IF THE DOWNWARD LIQUID VELOCITY IS LESS THAN 6 INCHES PER SECOND.
A LIQUID COLUMN HAVING AN AREA OF 1 SQUARE INCH TRAVELLING AT A VELOCITY OF 6 INCHES PER SECOND IS A RATE OF APPROXIMATELY 50 BPD.
Gas Rise Velocity is approximately 6 inches per second.
Gas Separation from Liquid
Gas Separator Liquid Capacity is based on the Following Principle:
3 2011 Sucker Rod Pumping Workshop Sept. 27 - 30, 2011
Natural Gas Anchor
The most efficient downhole gas separators locate the pump intake below the lowest gas entry point.
4 2011 Sucker Rod Pumping Workshop Sept. 27 - 30, 2011
Improved Natural Gas Anchor
Maximum flow area in casing annulus below pump.
5 2011 Sucker Rod Pumping Workshop Sept. 27 - 30, 2011
Liquid Capacity for Various Annular Areas
Natural Gas Anchor
6 2011 Sucker Rod Pumping Workshop Sept. 27 - 30, 2011
“Poor Boy” Gas Separator above perforations
A small, long dip tube within a small diameter separator.
Very poor design with a small outer tube ID and long flow paths.
Only acceptable for low volume wells.
7
“Poor Boy” Gas Separator – Very Common
Seating Nipple
Collar
Perforated Sub
Collar Joint of Tubing
Dip Tube Tubing Collars prevent perforated sub from laying against casing wall where liquid accumulates
Casing
Limited Flow Area and Small 3/8 inch holes in a perforated sub limit liquid entry flow and gas exit flow thus reducing separation efficiency
8 2011 Sucker Rod Pumping Workshop Sept. 27 - 30, 2011
“Poor Boy” Gas Separator Liquid Capacity
9 2011 Sucker Rod Pumping Workshop Sept. 27 - 30, 2011
Collar-Size Separator Increases Liquid Capacity
A good separator must strike a balance between annular flow area, separator flow area, dip tube diameter and pressure drop. Outer barrel OD same as collar OD. Thin wall outer barrel and dip tube. Short flow conduits. Large inlet ports.
10 2011 Sucker Rod Pumping Workshop Sept. 27 - 30, 2011
To get gas capacity of a specific installation multiply the table value by the Pressure at the Pump Intake (psi) and divide by 14.7 11
2011 Sucker Rod Pumping Workshop
Packer Gas Separator
Uses gravity separation like the “Poor Boy” except much more separation area and capacity.
Higher cost and higher risk of mechanical and sand problems.
12 2011 Sucker Rod Pumping Workshop Sept. 27 - 30, 2011
Concentric Packer Gas Separator
Sept. 27 - 30, 2011 2011 Sucker Rod Pumping Workshop 13
A concentric packer type gas separator offers additional liquid and gas capacities.
Diverter Gas Separator Animation
Pump
Sept. 27 - 30, 2011 14
Diverter Gas Separator Animation
Pump
Sept. 27 - 30, 2011 15
2011 Sucker Rod Pumping Workshop
Pump
Discharge Port Above Diverter for Reservoir Fluid
Sept. 27 - 30, 2011 16
Separator Parts
Sept. 27 - 30, 2011 2011 Sucker Rod Pumping Workshop 17
Separator Parts
17
Premium Rubber Diverter Cups The diverter cups are constructed from high temperature, flexible, wear-resistant, premium elastomer.
Sept. 27 - 30, 2011 2011 Sucker Rod Pumping Workshop 18
316 Stainless Steel
Separator Parts
Premium Rubber Diverter Assembly
Premium Rubber Diverter Cups Multiple cups can be utilized as desired
Sept. 27 - 30, 2011 2011 Sucker Rod Pumping Workshop 19
Separator Parts
2011 Sucker Rod Pumping Workshop
Shear Pins
Shear pins are located below the diverter cups. The force required to shear the shear pins is operator selectable. Factory setting is 4000 pounds. If the diverter cups are not retrievable with the gas separator, the cups will be left in the well with the shear pins and shear collar.
Pump
Sept. 27 - 30, 2011 20
Sept. 27 - 30, 2011
Sand Accumulation
Sand or debris may deposit above the swab cup flow diverter. If 5 inches of sand accumulates over the diverter between the gas separator and the casing wall, the flow of liquid into the gas separator will cease and production from the tubing will cease. When sand or debris is blocking the gas separator liquid inlet ports, a fluid level test will indicate a high fluid level in the casing annulus and a dynamometer pump card will indicate low or no pump fillage. The well will require servicing.
Pump
2011 Sucker Rod Pumping Workshop 21
Sept. 27 - 30, 2011
Sand Accumulation When the pump is unseated, liquid in the tubing will flow down the tubing and discharge out of the gas separator through the gas separator liquid inlet ports. The discharging liquid will be at high pressure. This will wash the sand and debris away from above the diverter. The discharging liquid will flow up the casing annulus and carry the sand. Probably ½ of the liquid and sand will flow down through the gas separator into the lower portion of the casing below the diverter. Reseat the pump and pump the well. Perform the liquid level test and dynamometer test to insure the well is operating properly.
Pump
2011 Sucker Rod Pumping Workshop 22
Sept. 27 - 30, 2011
Sand Accumulation - Shear Pin Sand can accumulate above the gas separator diverter and cause difficulty in removing the gas separator and diverter from the well. Retrieval of the gas separator and diverter may still be a problem even after flushing sand from above the diverter. A shear pin is located at the bottom of the swab cup diverter on the gas separator so that the gas separator can be removed from the diverter and retrieved from the well. The shear pin holds the diverter swab cups to the gas separator. When the shear pin is sheared, the gas separator can be separated from the diverter swab cups and removed from the well. The shear pin will shear at 4000 # (pre-set).
Pump
2011 Sucker Rod Pumping Workshop 23
2011 Sucker Rod Pumping Workshop
Fluid Pressures Surrounding Separator
Pump
58 psi Fluid Discharge Pressure
60.5 psi Liquid Inlet Pressure
60 psi Separator Inlet Pressure Sept. 27 - 30, 2011 24
2011 Sucker Rod Pumping Workshop
Installation Pump
A tubing anchor is installed 3 joints above the separator to prevent tubing and Diverter Gas Separator movement during pump operation.
Water or liquid lubricant can be added to casing annulus or tubing when the rubber diverters are above the liquid level in the well when running the Diverter Gas Separator into the well.
Sept. 27 - 30, 2011 25
Diverter Gas Separator Capacity 2.5 OD Outer Separator Barrel ~ 60 Psig Intake Pressure
2011 Sucker Rod Pumping Workshop 26 Sept. 27 - 30, 2011
Producing BHP Recommendation A PBHP of 10% of SBHP insures producing 97% of Well’s Max Rate
Use Efficient Downhole Gas Separators to:
INCREASE OIL AND GAS PRODUCTION
IMPROVE EFFICIENCY OF THE LIFT SYSTEM
CORRECT ARTIFICIAL LIFT PROBLEMS CAUSED BY INCOMPLETE PUMP FILLAGE DUE TO GAS INTERFERENCE
REDUCE OPERATING COST
2011 Sucker Rod Pumping Workshop 28 Sept. 27 - 30, 2011
Sept. 27 - 30, 2011 2011 Sucker Rod Pumping Workshop 29
Copyright
Rights to this presentation are owned by the company(ies) and/or author(s) listed on the title page. By submitting this presentation to the Sucker Rod Pumping Workshop, they grant to the Workshop, the Artificial Lift Research and Development Council (ALRDC), and the Southwestern Petroleum Short Course (SWPSC), rights to:
– Display the presentation at the Workshop. – Place it on the www.alrdc.com web site, with access to the site to be as
directed by the Workshop Steering Committee. – Place it on a CD for distribution and/or sale as directed by the Workshop
Steering Committee.
Other use of this presentation is prohibited without the expressed written permission of the author(s). The owner company(ies) and/or author(s) may publish this material in other journals or magazines if they refer to the Sucker Rod Pumping Workshop where it was first presented.
Sept. 27 - 30, 2011 2011 Sucker Rod Pumping Workshop 30
Disclaimer The following disclaimer shall be included as the last page of a Technical Presentation or Continuing Education Course. A similar disclaimer is included on the front page of the Sucker Rod Pumping Web Site. The Artificial Lift Research and Development Council and its officers and trustees, and the Sucker Rod Pumping Workshop Steering Committee members, and their supporting organizations and companies (here-in-after referred to as the Sponsoring Organizations), and the author(s) of this Technical Presentation or Continuing Education Training Course and their company(ies), provide this presentation and/or training material at the Sucker Rod Pumping Workshop "as is" without any warranty of any kind, express or implied, as to the accuracy of the information or the products or services referred to by any presenter (in so far as such warranties may be excluded under any relevant law) and these members and their companies will not be liable for unlawful actions and any losses or damage that may result from use of any presentation as a consequence of any inaccuracies in, or any omission from, the information which therein may be contained. The views, opinions, and conclusions expressed in these presentations and/or training materials are those of the author and not necessarily those of the Sponsoring Organizations. The author is solely responsible for the content of the materials. The Sponsoring Organizations cannot and do not warrant the accuracy of these documents beyond the source documents, although we do make every attempt to work from authoritative sources. The Sponsoring Organizations provide these presentations and/or training materials as a service. The Sponsoring Organizations make no representations or warranties, express or implied, with respect to the presentations and/or training materials, or any part thereof, including any warrantees of title, non-infringement of copyright or patent rights of others, merchantability, or fitness or suitability for any purpose.