Deutsche Power Electronics e.K. Power of your company
CATALOGUE
Company Profile & History
DP Electronics e.K (Deutsche Power Co) Founded in 1989 based in Darmstadt Germany, is an independently
owned international corporation, offering an established and effective range of power protection products, services
and sells to a very broad spectrum of industries and sectors.
DP Electronics e.K (Deutsche Power Co) is a high-tech enterprise specialized in power supply business with an
excellent R&D team formed by over 350 engineers and a skilled, dedicated workforce, has innovated, developed and
improved the products to meet the demands of customers and keep pace with changing demands of the industries.
With two International offices located in Germany and Hong Kong with Five OEM/ODM Assembling Partners in Hong
Kong, Hungary, China, Taiwan and Germany, Deutsche Power ensure to offer most reliable, economical, durable and
state of art technology products.
Quality & Reliability
DP Electronics e.K has a very strict and briefed quality assurance
system. All of our Products are verified through Strict QC
Checkup and all of our OEM/ODM Assembling Plants follow same
manufacturing standards as outline by Deutsche Power Co., Head
office in Germany. We have strict QC standards and believe in
quality products. Therefore all of our Products whether
assembled in Germany, Hong Kong, China, Taiwan or Hungary
have the same standards and quality.
Mission
Our mission is to be the best supplier of power solutions, and to
accomplish this, we will continue to tailor products for market
needs while maintaining high quality, integrated customer service
and prompt delivery.
Product Development
The cycle time for the development of new models of UPS is rapidly shortening as manufacturers take
advantage of the latest advances in microprocessor and power semiconductor devices developed by the
world’s component suppliers. These advances mean that our products are becoming lighter, smaller and
increasingly intelligent with a dramatic affect on cost reduction allowing DP Electronics e.K to provide even
more commercially viable solutions.
Manufacturing & Design
Today, the range of UPS includes more than 60 different models/Ratings. From the smallest to the largest units, the manufacturing process is rigorously monitored to ensure the highest levels of reliability, quality and safety are achieved, in accordance with key International Standards. Again DP Electronics e.K makes widespread use of the very latest technologies throughout our product portfolio.
Deu
tsch
e P
ow
er E
lect
ron
ics
e.K
.
Po
we
r o
f yo
ur
com
pan
y
Product Index
Our comprehensive product lines include uninterruptible power supply (UPS) systems ranging from 500VA
for personal computers to400kVA or more with parallel system redundancy for mission-critical applications,
including data centers, networking providers, and server farms. The easy-to-use power management software
provides monitoring, alarm and shutdown capabilities to allow customers manage power.
Our models ranges are as follows:-
Product Range Topology Applications
………………………………………………………………………………………………………………………………………………………………………..
XL Series 500VA ~ 3 KVA Line-Interactive Work Stations, Computer Peripherals,
Square/Step Sine Wave Point of Sale Equipment, Hubs, Routers
Single Phase In & Out
………………………………………………………………………………………………………………………………………………………………………..
DH series 1KVA~ 6 KVA Line-Interactive Domestic Applications, Work Stations,
Pure Sine wave Servers, Motorized Load, Hubs, Routers,
Single Phase In & Out Network stations, Gateways, PABX
………………………………………………………………………………………………………………………………………………………………………..
ACE LF Series 1KVA~20KVA Online Double Conversion Critical Servers, Small business Servers,
Pure Sine Wave Network Stations, Clustered PC Servers,
Single Phase In & Out Process Control, Laboratory Instruments,
………………………………………………………………………………………………………………………………………………………………………..
Elektra series (1/1) 1KVA~10KVA Online Double Conversion Critical Servers, Small business Servers,
Pure Sine Wave Network Stations, Clustered PC Servers,
Single Phase In & Out Process Control, Laboratory Instruments,
Medical Equipments
………………………………………………………………………………………………………………………………………………………………………..
Elektra Series (3/1) 10KVA~60KVA Online Double Conversion Large mainframe oriented data centers, Pure Sine wave Computer rooms; small mainframe, mini Three Phase In &Single Phase Out Computers, centralized or clustered
servers, Telecommunications applications Medical analysis equipment such as MRI and CAT scanners, Network Stations Mission critical customized Solutions
………………………………………………………………………………………………………………………………………………………………………..
Elektra Series (3/3) 10KVA~400KVA Online Double Conversion Large mainframe oriented data centers, Pure Sine wave Computer rooms; small mainframe, mini Three Phase In &Three Phase Out Computers, centralized or clustered
servers, Telecommunications applications Medical analysis equipment such as MRI and CAT scanners, Network Stations Mission critical customized Solutions
………………………………………………………………………………………………………………………………………………………………………..
Fuhrer Series (3/3) 10 KVA 100KVA Online Modular UPS Online Double Conversion Pure Sine wave Large mainframe oriented data centers, Three Phase In &Three Phase Out Computer rooms; small mainframe, mini
Computers, centralized or clustered servers, Telecommunications applications Medical analysis equipment such as MRI and CAT scanners, Network Stations Mission critical customized Solutions
………………………………………………………………………………………………………………………………………………………………………..
Batteries 7AH~500AH Sealed Lead Acid, Gel UPS systems, Fire alarm and security Nickel Cadmium & EV Ranges systems Industrial control systems, 5, 10 & 15 Year Design Life Emergency lighting
Model and toy products, Sports and leisure equipment Computer / network products Mobility vehicles Telecom equipment Portable equipment
Deu
tsch
e P
ow
er E
lect
ron
ics
e.K
.
Po
we
r o
f yo
ur
com
pan
y
XL Series Line-Interactive UPS
UPS For Complete IT Products (For SMEs with Standard autonomy) ……………………………………………………………………………………………………………………………………………………………………
………………………………………………………………………………………………………………….…..
Technical Specifications:- Model XL-60 Xl-100 XL-20 XL-30
Rating VA/Watts 600VA/3600W 1000VA/600W 2000VA/1200W 3000VA/1800W
Input:
Phase Single Phase In & Single Phase Out
Voltage 220V/230V/240V +25%
Frequency 50Hz +10%
Output
Wave Form Simulated Sine Wave
Voltage 220V/230V/240V +10%
Frequency 50Hz+1%
Crest Factor 3:1
Transfer Time <2msec
Sockets Universal
Battery
Type 1X7AH 2X7AH 6X7AH 6X8AH
Quantity
Recharge 90% within 5 Hrs
Backup Approx 10-15 minutes (depending on Load)
General
Surge RJ11 & RJ45for Modem & Lan Cable attached (Optional)
Communication Rs232 OR USB (Optional)
Noise <45dB (1 Meter)
Temperature 0~40C
Humidity 20~90% (Non-Condensing)
Dimensions 320X163X96 390X123X127 490X470X340
Deu
tsch
e P
ow
er E
lect
ron
ics
e.K
.
Po
we
r o
f yo
ur
com
pan
y
Features: Highly synchronous transfer. Compact Design Wide input range (220V ± 25%). Cold start available Strong generator compatibility Automatic battery charging in UPS off mode. Surge protection. With strong electromagnetism compatibility, no
electromagnetic interference to load. Software monitoring feature.( RS232 & USB) Full protections against over voltage /low voltage Intelligent battery management
Overload Protection
Simulated Sine wave with Fully AVR
Cold Start
DH Series Line-Interactive Sine Wave UPS
Single Solution for All Domestic and IT Applications (For SMEs with Standard & Extended Autonomy with Sine Wave Output) ……………………………………………………………………………………………………………………………………………………………………………
……………………………………………………………………………………………………………………………………………………………………………
Technical Specifications:- Model DH512 DH712 DH1024 DH2024 DH3024 DH3524
Rating KVA/Watts 1KVA/600W 1.5KVA/800W 2KVA/1100W 3KVA/2000W 5KVA/3000W 6KVA/3500W
Input:
Phase Single Phase In & Single Phase Out
Voltage 150v-280v AC
Frequency 50Hz +10%
Output
Wave Form Sine Wave
Voltage 220V/230V/240V +10%
Frequency 50Hz+1%
Crest Factor 3:1
Transfer Time <2msec
Sockets Universal
Battery
Type (Extended Autonomy) 12VDC 48VDC
Quantity (Standard Autonomy) 1X12AH 2X9AH 2X12AH 4X9AH 4X12AH 4X17AH
Recharge 90% within 5 Hrs
Backup (10-15 Min for Standard Autonomy) (Variable on extended Autonomy)
General
Surge RJ11 & RJ45for Modem & Lan Cable attached (Optional)
Communication Rs232 OR USB (Optional)
Noise <45dB (1 Meter)
Temperature 0~40C
Humidity 20~90% (Non-Condensing)
Dimensions 372*122*195 379*145*215
The above sizes are for the UPS Cubicle only , battery cabinet sizes and weight has to be added separately
Features:
Can bear all kind of Loads Highly synchronous transfer. Extended & Short Autonomy models Available Compact Design Wide input range (220V ± 25%). Strong Charger Up to 10~15 A Surge protection. Software monitoring feature.( RS232 & USB) Full protections against over voltage /low voltage Intelligent battery management
Overload Protection
Reverse Polarity Protection
Cold Start
Deu
tsch
e P
ow
er E
lect
ron
ics
e.K
.
Po
we
r o
f yo
ur
com
pan
y
ACE LF Series Online Double Conversion Low Frequency Sine Wave UPS
Ultimate Power Protection for Mission Critical Applications (For IT & Mission Critical Equipments)
……………………………………………………………………………………………………………………………………………………………………………
……………………………………………………………………………………………………………………………………………………………………………
Features: Low Frequency Design
Online Double Conversion DSP , PWM Based
Advanced High speed IGBT Structure
Output with Isolation Transformer
Cold Start Functions
PFC Technology
EMI/RFI Noise Filters
Lightening & Surge Protections (1050 Joules) Self diagnostic at UPS startup
True Sine Wave Output
Cold Start
ACE LF Series is the world most advanced true Online Low Frequency UPS. ACE LF Series adopts Digital Signal processor technology, uses high current high voltage intelligent power module , High speed IGBT drive IC and professional; drive circuit. This series totally isolates its connected load from every power problem that arises from the mains supply. It ensures 100% protection to the load from the full range of disturbances including harmonics , common mode noise, and fault conditions on the input bus and vice versa.
Cold Start
Applications Critical Servers
Small business Servers
Network Stations,
Clustered PC Servers
Process Control,
Laboratory Instruments,
High Sensitive Equipments
old Start
Deu
tsch
e P
ow
er E
lect
ron
ics
e.K
.
Po
we
r o
f yo
ur
com
pan
y
Technical Specifications:-
Model ALF ALF ALF ALF ALF ALF ALF ALF ALF
2001 2002 2003 2005 2006 2008 2010 2015 2020
Rating 1KVA 2KVA 3KVA 5KVA 6KVA 8KVA 10KVA 15KVA 20KVA
Input Voltage 220Vac±25%
Frequency 50Hz±10%
Control method Mosfet IGBT SPWM
Output
Voltage 220Vac±1%
Frequency 50Hz±1% (Batt . Mode)
Wave Sine wave, THD<3% (0-100% linear load)
Overload Transfer to bypass within 10s if the load is more than 120%;
Power rate 0.8 lagging
Peak rate 3:1
Dynamic
respond range Load changes from 0% to100% or from 100% to 0%, the change of output voltage is less than ±4%
AC fault transfer time 0 ms
Batt.
Type VRLA battery
Backup time 5-10Min
DC voltage 48V 96V 120V 192V
Charge time <7Hrs
Efficiency (AC/Battery) >80% >83% >85% >88%
Protection Short circuit protection; Surge voltage protection;
Safety standard IEC60950, GB4943
Electromagnetism compatible EN50091, GB9245
Display LED indicator light: AC input/ Bypass/ Inverter/ Battery/ Overload
Communication interface RS232, SNMP(Option)
Environment Temperature 0-40ºC
Humidity 0-90%(Non-condensing)
Noise <55dB <60dB
Dimension
L x W x H mm
439x235 x350 608x237x496 583x264x620 550x400x1000
580x480 x1190
Weight Kg 36 55.5 63.5 90.5 99 120 139 176 222
Deu
tsch
e P
ow
er E
lect
ron
ics
e.K
.
Po
we
r o
f yo
ur
com
pan
y
ELEKTRA SERIES Mission Critical, IT & Industrial Usage UPS
(01 KVA ~400KVA)
(Single Phase In & Out, Three Phase In & Single Phase Out & Three Phase In & Three Phase Out)
ELEKTRA SERIES Single Phase In & Out
Ultimate Power Protection for Mission Critical Applications (For IT & Mission Critical Equipments)
…………………………………………………………………………………………………………………………………………………………………………
Features: • True double conversion • Advanced digital signal processor control technology • Wide input voltage and frequency windows • LCD mimic panel • Near unity power factor • Output power factor 0.8 • ECO mode operation for energy saving • Extended runtime capability • Emergency shutdown control through EPS • Smart battery charger • Customer options slot • Communication software provided • N+X parallel redundancy 6K and above • Programmable power management outlets
Cold Start
Elektra is the world's most advanced High Frequency Uninterruptible Power Supply. Elektra series UPS adopts Central Processing Unit(CPU) control Technology, and use double-conversion circuit design, it supply pure sine wave power with stable voltage, stable frequency. It guarantees full safety of your highly sophisticated equipment. The input power factor is more than 95% and the output Power Factor is 0.8. This reduces more Mains pollution and power loss than equivalent traditional UPS. So it is a Energy-Saving, Green and Clear power system. Elektra Series is available in Tower as well as Rack mount version.
Cold S
Standards FOR 1/2/3 KVA UPS products comply with:
EN50081-1 / EN55022 Class B EN50082-1 / IEC801-2 LEVEL 4 IEC801-3 LEVEL 3 IEC801-4 LEVEL 4 IEC801-5 LEVEL 2 (1) 1000VA, 2000VA, and 3000VA (220/230V -version) products comply with: FCC Part 15 Class A IEEE587 Class A (2) The products of 3000VA (220/230V -version) are Class A digital devices.
FOR 6K/10K/15K UPS products comply with: EN62040-1-1 (Safety) Conducted Emission: EN50091-2: Limits for UPS which have a rated output current exceeding 25A (25~100A) Radiated Emission: EN50091-2: Limits for UPS which have a rated output current exceeding 25A (25~100A) EMSEN61000-4-2(ESD)………………………..Level 4 EN61000-4-3(RS)………………………….Level 3 EN61000-4-4(EFT)………………..……….Level 4 EN61000-4-5(Lightning Surge)…………..Level 4 EN61000-2-2 (Immunity to low frequency signal) Safety Comply with GB4943-2001, IEC62040-1 and CE requirements. Industry Standard
Comply with EN62040,YD/T 1095-2000 requirements.
Cold Start
Applications Large mainframe oriented data centers Computer rooms; Small mainframe Mini computers, Centralized or clustered servers Telecommunications applications Medical analysis equipment such as MRI and CAT scanners Laboratory instrumentation Mission critical customized applications
Cold Start
Deu
tsch
e P
ow
er E
lect
ron
ics
e.K
.
Po
we
r o
f yo
ur
com
pan
y
Technical Specifications:-
Model ES101 ES101S ES102 ES102S ES103 ES103S ES106 ES106S ES110 ES110S
Rating 1KVA/800W 2KVA/1600W 3KVA/2400W 6KVA/4800W 10KVA/8000W
Input
Input system Single phase & earth ground Single phase +Neutral+ ground
Rated voltage 220VAC
Voltage range 115VAC~300VAC 176VAC~276VAC
Frequency 50Hz
Power factor ≥0.99
Voltage range of bypass
(80±5)VAC~(286±5)VAC
Output
Output system Single phase & earth ground Single phase +Neutral+ ground
Rated voltage 220VAC
Power factor 0.8
Voltage precision ±2% ±1%
Output frequency
Normal mode
1.The output frequency synchronizes with the input frequency when the input frequency is in the
range of 46 Hz~54 Hz
2.The output frequency is 50Hz when the input frequency is not in the range of 46 Hz~54 Hz Battery mode
Inverter overload
capacity (Utility
power,25℃)
105%±5%<Load≤125%±5% 50s transfer to bypass 125%±5%< Load <150%±5% 25s transfer to bypass
Load > 150%±5%,300ms transfer to bypass
Transfer time 0ms (Normal mode←→ Battery mode)
<4ms(Normal mode←→Bypass mode)
Crest factor 3:1
Battery
Batteries voltage 36VDC 72VDC 96VDC 192VDC
Battery Quantity 3 none 6 none 8 none 16 none 16 none
Battery Type Sealed maintenance-free lead –acid battery of battery voltage 12V/7AH
Backup Time(25℃) Full load≥5min (Standard)
Charge current 1A 7A 1A 7A 1A 7A 2A 8A 2A 8A
General Ambient Temp 0℃~40℃
humidity 20%~90%(No condensation)
Altitude Lower than 1000m: no derating Over 1000m :1% derating for every 100m rise
Storage Temp -15℃C~45℃C
Dimensi
ons
Size (WXHXD)mm 144 229 350
144 229 350
190 328 424
190 328 424
190 328 424
190 328 424
260 570 717
260 570 717
260 570 717
260 570 717
Weight Kg 11.5 6 24 12 28 12 90 35 93 38
Deu
tsch
e P
ow
er E
lect
ron
ics
e.K
.
Po
we
r o
f yo
ur
com
pan
y
ELEKTRA SERIES (3/3, 3/1) Three Phase UPS
Ultimate Power Protection for Mission Critical Applications (For Industrial, IT & Mission Critical Equipments)
…………………………………………………………………………………………………………………………………………………………………………
Applications Industrial Machineries Large mainframe oriented data centers Computer rooms; Small mainframe Mini computers, Centralized or clustered servers Telecommunications applications Medical analysis equipment such as MRI and CAT scanners Laboratory instrumentation Mission critical customized applications
Cold Start
Features: • 3/3 Phase & 3/1 Phase •DSP based PWM technology using IGBT • Double Conversion VFI Technology • LCD Touch Screen • Near unity power factor • Output power factor 0.8 • ECO mode operation for energy saving • Extended runtime capability • Emergency shutdown control through EPS • Smart battery charger • DRY Contact • Communication software provided • Redundant Parallel, support 1+1, N+1, N+X connection
Cold Start
Standards SNMP Connectivity EN62040-1-1 (Safety) Conducted Emission: EN50091-2 Radiated Emission : EN50091-2 EMSEN61000-4-2(ESD) …………………….Level 4 EN61000-4-3 (RS)……………………………Level 4 EN61000-4-(EFT)…………………………….Level 4 EN61000-4-5(Lightning surge)……………...Level 4 EN61000-2-2 (Immunity to low Frequency signal)
Cold Start
Elektra Series is available in 3/3 as well as 3/1. The range of capacity is from 10
KVA to 400KVA (Stand Alone). It supports redundant parallel connected up to 8 sets. Each set of UPS will share load automatically. Elektra series incorporates Digital Signal Processor (DSP) Technology, Application Specific Integrated Circuit (ASIC) and large power IGBT. It is unmatched in reliability and ensure very low running costs, thereby guaranteeing good returns due to energy saving. Since it provides 100% Pure Sine Wave output, it guarantees full safety of your highly sophisticated Equipments.
Cold Start
Touch Screen LCD with more than 150
parameters
Deu
tsch
e P
ow
er E
lect
ron
ics
e.K
.
Po
we
r o
f yo
ur
com
pan
y
Technical Specifications (Three Phase In & Out ):-
Model ES1033 ES1533 ES2033 ES3033 ES4033 ES6033 ES8033
Rating (VA) 10KVA 15KVA 20KVA 30KVA 40KVA 60KVA 80KVA
Principle of working True On-line, Double Conversion, Static Bypass Switch, Output with isolation
transformer
AC Input
Phase Three phases + N + G
Voltage 380V±20%
Frequency 50Hz±10%
Max. current 19 29 38 57 76 114 152
Power rate ≥0.8
Soft start 0-100% 5Secs
Bypass Input
Phase Three phases + N + G
Voltage 380V±15%
Phase 50Hz±5%
Transfer time 0ms
DC system
DC voltage 384V (12V X 32 Cells)
Float Chg. Volt. 432V
End voltage 336V
Max. dischg. current
25 38 51 76 101 152 203
Chg. current 10-25A (Adjustable)
AC output
Phase Three phases + N + G
Voltage 380V±1% (Stable load)
Frequency 50Hz±0.1% (Battery)
Power rate 0.8 Lagging
Wave Sine wave
THD Linear load<3%, Non-linear load<5%
Dynamic respond range
±5% (From 0 to 100%)
Dynamic respond time
<10ms (±5%)
Volt. Undulation <±3% (Unbalance Load); <±1% (Balance Load)
Overload 125% 10mins; 150% 1mins ; >150% 200ms
Working efficiency >91%, 95%, ECO
Communication RS232/RS422, SNMP(Option)
Temperature 0-50ºC
Humidity 0-90%
Noise 50dB 55dB 63dB 65dB
Dimension(L x W x H) 800x560x1140mm 950x850x1800mm 1200x900x180
0mm
Weight (Kg) 210 258 350 400 480 650 900
Deu
tsch
e P
ow
er E
lect
ron
ics
e.K
.
Po
we
r o
f yo
ur
com
pan
y
Technical Specifications (Three Phase In & Out):-
Model ES10033 ES12033 ES14033 ES16033 ES20033 ES25033 ES30033
Rating (VA) 100KVA 120KVA 140KVA 160KVA 200KVA 250KVA 300KVA
Principle of working True On-line, Double Conversion, Static Bypass Switch, Output with isolation transformer
AC Input
Phase Three phases + N + G
Voltage 380V±20%
Frequency 50Hz±10%
Max. current 189 227 265 303 379 473 568
Power rate
≥0.8 ≥0.9
Soft start 0-100% 5Secs
Bypass Input
Phase Three phases + N + G
Voltage 380V±15%
Phase 50Hz±5%
Transfer time 0ms
DC system
DC voltage 396V (12V X 33 Cells)
Float Chg. Volt. 446V
End voltage 347V
Max. dischg. current
253 304 360 425 528 660 790
Chg. current 10-25A (Adjustable)
AC output
Phase Three phases + N + G
Voltage 380V±1% (Stable load)
Frequency 50Hz±0.1% (Battery)
Power rate 0.8 Lagging
Wave Sine wave
THD Linear load<3%, Non-linear load<5%
Dynamic respond range
±5% (From 0 to 100%)
Dynamic respond time
<10ms (±5%)
Volt. Undulation <±3% (Unbalance Load); <±1% (Balance Load)
Overload 125% 10mins; 150% 1mins ; >150% 200ms
Working efficiency >91%, 95%, ECO
Communication RS232/RS422, SNMP(Option)
Temperature 0-50ºC
Humidity 0-90%
Noise 65dB 68dB
Dimension(L x W x H) 1200x900x1800
mm 1300x950x1800 2000x900x1800 2400x900x1800
Weight (Kg) 1200 1350 2000 2950
Deu
tsch
e P
ow
er E
lect
ron
ics
e.K
.
Po
we
r o
f yo
ur
com
pan
y
Technical Specifications (Three Phase In &Single Phase Out):-
Model ES1031 ES1531 ES2031 ES3031 ES5031 ES6031
Rating 10 KVA 15 KVA 20 KVA 30 KVA 50 KVA 60 KVA
Input Voltage 380Vac±20%
Frequency 50Hz±10%
Control method IGBT SPWM
Output
Voltage 220Vac±1%
Frequency 50Hz±1% (Batt . Mode)
Wave Sine wave, THD<3% (0-100% linear load)
Overload ability
Transfer to bypass within 10s if the load is more than 120%;
Power rate 0.8 lagging
Peak rate 3:1
Dynamic respond range
Load changes from 0% to100% or from 100% to 0%, the change of output voltage is less than ±4%
AC fault transfer time 0 ms
Batt.
Type VRLA battery
Backup time 5-10Min
DC voltage 384VDC
Charge time <7Hrs
Efficiency (AC/Battery) >88%
Protection Short circuit protection; Surge voltage protection;
Safety standard IEC60950, GB4943
Electromagnetism compatible EN50091, GB9245
Display LED indicator light: AC input/ Bypass/ Inverter/ Battery/ Overload
Communication interface RS232, SNMP(Option)
Environment Temperature 0-40ºC
Humidity 0-90%(Non-condensing)
Noise <55dB
Dimension L x W x H
mm 800x560x1140
Deu
tsch
e P
ow
er E
lect
ron
ics
e.K
.
Po
we
r o
f yo
ur
com
pan
y
FUHRER SERIES Modular Redundant UPS
Ultimate Power Protection for Mission Critical Applications (For Industrial, IT & Mission Critical Equipments)
Deutsche Power Fuhrer Series is a Multi-Standard Modular High frequency technology
Parallel redundant UPS system. The system is composed of three modules: Display &
Control Module, Inverter Module (1 to 10 inverter modules of 10kVA each) and Bypass
Module. The Inverter Module is designed for hot-swappable. Modular design ensures
flexible options for expansion. Redundant UPS technology allows users to scale their
power capacity and provide continuous and highest availability. Great power density
ensures a small footprint and low heat dissipation. Rich management and communication
functions ensure a friendly man-machine conversation interface.
Cold Start
Features DSP Control & Modular design Parallel & Redundant Dual conversion technology Advanced PFC technology True Sine Wave output Intelligent battery management Configurable as 3/3, 3/1, 1/1, 1/3 system Hot- swappable High efficiency for power savings Transform less
Cold Start
Applications Industrial Machineries Large mainframe oriented data centers Computer rooms; Small mainframe Mini computers, Centralized or clustered servers Telecommunications applications Medical analysis equipment such as MRI and CAT scanners Laboratory instrumentation Mission critical customized applications
Cold Start
Control Module By-Pass Module Inverter Module Cold Start
Touch Screen LCD with more than 150
parameters
Deu
tsch
e P
ow
er E
lect
ron
ics
e.K
.
Po
we
r o
f yo
ur
com
pan
y
Technical Specifications :-
Model FS-10 FS-20 FS-30 FS-40 FS-50 FS-60 FS-70 FS-80 FS-90 FS-100
Rated Power 10KVA 20KVA 30KVA 40KVA 50KVA 60KVA 70KVA 80KVA 90KVA 100KVA
Technical Type True online double conversion
Construction /Modular parallel hot-plugged modules,
AC Input Voltage 3 phase 4 wires input (rated voltage 380Vac) or single phase 2 wires input (rated voltage 220Vac)
Voltage Range Line voltage 277~468Vac or phase voltage 160~270Vac
Frequency Voltage
50Hz±5Hz or 60Hz±5Hz
Power Factor 0.99
THDI ≤5%
AC output Output Waveform Standard sinusoidal
Output P.F 0.8
Output Phase 3phase 4 wires output (rated voltage 380Vac) or single phase 2 wires output (rated voltage 220Vac)
Output Voltage 380VAC+1% or 220Vac+1%
Output Frequency 50Hz±0.01Hz or 60Hz±0.01Hz (Main frequency during locking phase)
Peak Value Factor 3:1
Dynamic Response
≤10%
THD ≤2%(linear load) ; ≤5%(no-linear load)
Overload 110% 10min ; 120% 1min protection ; 150% 200ms (linear load)
Imbalance with Load
≤3%
Efficiency ≥96%
DC system Type VRLA
Nominal Voltage +Battery : +384Vdc , -Battery : -384Vdc ( +&- two group batteries support power )
General Noise ≤50db(100% load), Intelligent control for fans
Communication RS232 or RS422 、 RS485 、 network card
Standard EN 50091-1 , EMC EN 50091-2 Liv.A
Ambient Temperature
-10℃ ~+ 40℃ (Operating) ; -25~ 55℃ (Storage)
Relative Humidity 20%~93%
Dimensions (HxWxD)
UPS module : 2UX19X 455mm ; Weight : 13Kg
Bypass module : 6UX19X 455mm ; Weight : 25Kg
Display module : 4UX19X 455mm ; Weight : 9Kg
50KVA:1084x598x673mm ; 100KVA: 1552x598x673mm Standard Cabinet 1800x600x800mm
Deu
tsch
e P
ow
er E
lect
ron
ics
e.K
.
Po
we
r o
f yo
ur
com
pan
y
Batteries
Deu
tsch
e P
ow
er E
lect
ron
ics
e.K
.
Po
we
r o
f yo
ur
com
pan
y
GENERAL INFORMATION
Discharge Rate Backup Time
3.07C 5min
2.25C 10min
1.66C 15min
0.98C 30min
0.72C 45min
0.60C 60min
0.50C 1.5Hours
0.40C 2Hours
0.28C 3Hours
0.22C 4Hours
0.18C 5Hours
0.125C 8Hours
0.10C 10Hours
0.09C 12Hours
0.06C 20Hours
0.05C 24Hours
FEATURES Innovative Technical Features Benchmarking Technique - Semi-
automated Cast On Strap (COS) production, this unique production
together with a computer program (CUP) controlling welding
temperature and time to guarantee welding quality which provides
benefit of plate consistency and enhanced plate performance.
Terminals are formed in a single cast on strap operation that greatly
reduces the welding resistance of the terminals and increases their
current carrying capacity.
Valve Regulated (Sealed) Excessive Gas Absorption Construction
Deutsche Power battery is of the AGM (Absorbed Glass Mat) valve
regulated (sealed) lead acid rechargeable type. The acid is suspended in
a specially formulated non-woven glass mat separator.
Exceptional Leak Proof As all the acid is absorbed in the valve regulated
(sealed) construction which provides a safe Non-spillable battery that is
leak proof.
Gas Recombination System More than 99% of gasses generated in the
normal charge / discharge use of a rechargeable battery are internally
recombined during normal operating parameters.
Electrolyte Maintenance Free Operation The separator used is made of
non-woven fabric of fine glass fibers which have high resistance to acid
and low electro-conductivity. The high porosity of the separators
retains adequate electrolyte for the reaction of active materials in the
plates. As a result, no electrolyte maintenance is needed for the life of
the battery. There is no need to add water or take specific gravity
readings.
Low Self Discharge & Long Shelf Life Because of the use of lead calcium
alloy grids, Deutsche Power battery has less than 3% self-discharge
monthly at room temperature of 25oC and it can be stored for long
periods of time without recharge.
Long Service Life Deutsche Power battery is suitable for either cycling
or standby service. For Float (standby) service, the length of service is
generally 3-5 years depending on the Operating temperature of the
battery, Method of charging utilized, Correct sizing and the number &
depth of discharges. For cycling service, the estimated battery life is
more than 1000 charge / discharge cycles depending on the depth of
discharge.
Wide Operating Temperature Range DP battery has a wide operating
temperature range of -30oC to +45oC. However, for maximum life and
safety, continuous operation over 45oC is not recommended.
Non-hazardous Commodity Deutsche Power battery is classified as
non-hazardous commodity
CONFORMITY Conform to EU EMC – Directive 2004/108/EC EN 61000-6-1: 2007 EN 61000-6-3: 2007 IEC, JIS, UL, BS6290 - Part 4
IEC 60896-2/'04 and JIS C8704-2
Applications - Audio & Video Equipment - Burglar and Fire Alarm - Portable Lights - Office Machines - Electric Wheel chairs - Cash Registers - Test Equipment - Telecommunications - Geo physical Equipment - Solar Power Devices - Lawnmower - UPS Equipment - Riding Toys - Emergency Lighting - Robotics - Computers
Cold Start
Deu
tsch
e P
ow
er E
lect
ron
ics
e.K
.
Po
we
r o
f yo
ur
com
pan
y
Principle operation of valve regulated lead acid battery
The gassing and water loss reactions are as follows:
It is noted that the gassing reaction only generally occurs to any extent when the battery is almost totally charged. In the valve regulated battery it is obvious that water loss must be avoided. This is done by limiting the escape of hydrogen and oxygen from the battery. The design therefore accomplishes the recombination of the oxygen formed at the positive plate with the hydrogen formed at the negative plate. The reaction is as follows.
This virtually eliminates the production of free hydrogen at the negative plate to the action of recombination. However it is necessary to ensure that correct charging voltages are used. Valve Regulated Lead acid batteries are sometimes called recombinant cells because the construction provides a means of recombining the internally generated hydrogen and oxygen and the suppression of the evolution of hydrogen gas to limit the consumption of water from the electrolyte. Therefore the battery requires No addition of water during its normal life time. Deutsche Power valve regulated batteries are of the Absorbed Electrolyte type. The cells are designed so that a highly controlled amount of electrolyte is contained within a highly absorbent non-woven separator material that separates the battery plates. This type of separator construction allows the full wetting of the plates with the available electrolyte and also allows the passage of oxygen generated during charging, this method of construction is generally referred to as Absorbed Glass Mat (AGM) type of construction. Valve regulated batteries are sealed with the exception of a valve that opens when excess pressure builds up inside the battery. The valve automatically reseals itself. The recombination of charge gases is accomplished by allowing oxygen produced at the positive plate to pass through the separator material to the negative plate where the recombination reaction occurs. The valve controls the internal of the battery to optimize this efficiency of the recombination reaction and minimize the possible escape of electrolyte.
Deu
tsch
e P
ow
er E
lect
ron
ics
e.K
.
Po
we
r o
f yo
ur
com
pan
y
Operating Instructions Deutsche Power batteries are maintenance free. However, users are recommended to follow the instructions to keep the operation safe.
1. Do not install or operate the batteries near a heat source. High temperature will shorten the service life of battery. Furthermore, avoid placing the batteries close to fire. Fire can damage the ABS container and the inside gas will be leak out.
2. Battery cover and case are made of ABS plastic resin, which can be damaged, by organic solvents or adhesives. Never use such substance to clean the battery. Avoid using oils, gasoline or any kind of thinner. Use a piece of wet cloth instead.
3. Never touch the battery terminal or conductive parts with bare hand. Wear a rubber gloves to prevent electrical shock especially
when the batteries are connected together.
4. Soldering of batteries is dangerous. A fast soldering less than 3 seconds is comparatively safer. A soldering iron with maximum power of 100 watts should be used. However, soldering is still not recommended.
5. Do not mix batteries of different brand, type, capacity, age together. Professional guidance is needed for such kind of application.
6. Good ventilation must be provided if a battery is used in an enclosed area.
7. Always leave a minimum space of around 5-10mm between batteries when they are grouped together.
8. Shock and vibration should be prevented during the operation of batteries. Fasten the batteries with shock absorbing materials in
such applications.
9. Do not disassemble the battery. There is sulfuric acid contained in a lead acid battery that can cause a serious burning on skin and
eye.
10. Never short the battery. It could burn the battery and cause damages to the connected equipment.
11. When connecting the batteries together in a series or parallel way, user should use the connecting cable of same length and
resistance.
12. Before a long period storage, it is advisable to charge the batteries so that they can remain a minimum capacity to prevent over self-discharge.
Deu
tsch
e P
ow
er E
lect
ron
ics
e.K
.
Po
we
r o
f yo
ur
com
pan
y
Technical Specifications:-
VRLA Battery NP Series
5 years design life ABS case (Can be made with Flame retardant V0)
Battery Model
Specification
Dimensions(mm) Weight Kg±0.2Kg (Approx)
Capacity (AH) @ 25 ℃, 1.75V/Cell
L ±1
W ±1 H1 ±2
H2 ±2
1HR 3HR 5HR 10HR 20HR
NP4-12 12V4AH 90 70 102 106 1.52 2.3 3.05 3.45 3.8 4.0
NP4.5-12 12V4.5AH 90 70 102 106 1.70 2.65 3.4 3.83 4.2 4.5
NP5-12 12V5AH 90 70 102 106 1.90 3.0 3.8 4.3 4.8 5.0
NP5-12 L 12V5AH 151 51 93 99 2.00 3.0 3.8 4.3 4.8 5.0
NP6-12 12V6AH 151 65 94 99 2.15 3.3 4.5 5.1 5.7 6.0
NP7-12 12V7AH 151 65 94 99 2.30 4.2 5.4 6.1 6.8 7.0
NP7.5-12 12V7.5AH 151 65 94 99 2.40 4.5 5.7 6.5 7.2 7.5
NP8-12 12V8AH 151 65 94 99 2.50 4.6 6.0 6.8 7.5 8.0
NP9-12 12V9AH 151 65 94 99 2.60 5.0 6.8 7.7 8.5 9.0
NP12-12 12V12AH 151 98 98 102 3.80 7.0 9.1 10.5 11.0 12.0
NP14-12 12V14AH 151 98 98 102 4.10 8.0 10.6 12.0 13.0 14.0
NP18-12 12V18AH 181 76 165 165 5.40 9.9 13.5 15.3 17.0 18.0
NP20-12 12V20AH 181 76 165 165 7.50 12.0 15.3 17.5 18.5 20.0
NP24-12 12V24AH 177 167 125 125 8.00 13.5 18.5 21.0 22.5 24.0
NP26-12 12V26AH 165 126 176 176 8.1 14.8 19.5 22.0 24.0 26.0
NP28-12 12V28AH 166 125 175 175 9.7 15.5 21.0 24.0 26.0 28.0
NP33-12 12V33AH 196 131 155 166 10.5 18.3 25.0 28.2 32.0 33.0
NP38-12 12V38AH 197 165 170 170 13.3 22.0 29.0 33.0 38.0 40.0
NP44-12 12V44AH 197 165 170 170 14.5 24.2 35.0 39.5 44.0 46.0
NP55-12 12V55AH 228 137 208 227 18.6 32.0 43.0 47.5 55.0 58.0
NP65-12 12V65AH 350 168 179 179 21.3 38.0 50.0 57.0 65.0 68.0
NP70-12 12V70AH 259 168 208 213 22.0 41.0 54.0 61.0 70.0 73.0
NP80-12 12V80AH 259 168 208 231 24.0 45.0 61.0 69.0 80.0 85.0
NP90-12 12V90AH 307 169 208 213 26.8 51.0 69.0 78.0 90.0 100.0
NP100-12 12V100AH 328 172 214 219 30.5 59.0 78.0 88.0 100.0 110.0
NP110-12 12V110AH 328 172 214 219 31.2 61.0 79.0 90.0 110.0 120.0
NP120-12 12V120AH 409 177 225 225 36.0 70.0 92.0 105.0 120.0 130.0
NP135-12 12V135AH 341 172 282 288 41.8 75.0 102.0 115.0 135.0 148.0
NP150-12 12V150AH 483 170 241 241 44.5 87.0 115.0 130.0 150.0 165.0
NP160-12 12V160AH 532 207 214 240 53.4 90.0 122.0 140.0 160.0 176.0
NP180-12 12V180AH 532 207 214 240 56.3 105.0 140.0 155.0 180.0 198.0
NP200-12 12V200AH 522 240 218 244 61.5 115.0 152.0 172.0 200.0 220.0
NP230-12 12V230AH 521 269 203 206 66.0 127.0 172.5 196.0 230.0 250.0
NP240-12 12V240AH 521 269 203 206 67.0 135.0 182.0 206.0 240.0 260.0
NP250-12 12V250AH 520 269 220 223 76.0 140.0 190.0 215.0 250.0 270.0
Deu
tsch
e P
ow
er E
lect
ron
ics
e.K
.
Po
we
r o
f yo
ur
com
pan
y
VRLA Battery NPL Series High-Tin alloy design 12 years design life ABS case(Can be made with FR V0)
Battery Model
Specification
Dimensions(mm) Weight Kg±0.2Kg (Approx)
Capacity (AH) @ 25 ℃ , 1.75V/Cell
L ±1
W ±1 H1 ±2
H2 ±2
1HR 3HR 5HR 10HR 20HR
NP120-6-L 6V120AH 195 170 206 209 17.0 70.0 92.0 105.0 120.0 125.0
NP180-6-L 6V180AH 306 168 220 225 28.7 105.0 140.0 155.0 180.0 200.0
NP200-6-L 6V200AH 323 178 225 229 30.2 115.0 152.0 172.0 200.0 220.0
NP12-12-L 12V12AH 151 98 98 102 3.80 7.0 9.1 10.5 11.0 12.0
NP14-12-L 12V14AH 151 98 98 102 4.10 8.0 10.6 12.0 13.0 14.0
NP18-12-L 12V18AH 181 76 165 165 5.40 9.9 13.5 15.3 17.0 18.0
NP20-12-L 12V20AH 181 76 165 165 7.50 12.0 15.3 17.5 18.5 20.0
NP24-12-L 12V24AH 177 167 125 125 8.00 13.5 18.5 21.0 22.5 24.0
NP26-12-L 12V26AH 165 126 176 176 8.1 14.8 19.5 22.0 24.0 26.0
NP28-12-L 12V28AH 166 125 175 175 9.7 15.5 21.0 24.0 26.0 28.0
NP33-12-L 12V33AH 196 131 155 166 10.5 18.3 25.0 28.2 32.0 33.0
NP38-12-L 12V38AH 197 165 170 170 13.3 22.0 29.0 33.0 38.0 40.0
NP44-12-L 12V44AH 197 165 170 170 14.5 24.2 35.0 39.5 44.0 46.0
NP55-12-L 12V55AH 228 137 208 227 18.6 32.0 43.0 47.5 55.0 58.0
NP65-12-L 12V65AH 350 168 179 179 21.3 38.0 50.0 57.0 65.0 68.0
NP70-12-L 12V70AH 259 168 208 213 22.0 41.0 54.0 61.0 70.0 73.0
NP80-12-L 12V80AH 259 168 208 231 24.0 45.0 61.0 69.0 80.0 85.0
NP90-12-L 12V90AH 307 169 208 213 26.8 51.0 69.0 78.0 90.0 100.0
NP100-12-L 12V100AH 328 172 214 219 30.5 59.0 78.0 88.0 100.0 110.0
NP110-12-L 12V110AH 328 172 214 219 31.2 61.0 79.0 90.0 110.0 120.0
NP120-12-L 12V120AH 409 177 225 225 36.0 70.0 92.0 105.0 120.0 130.0
NP135-12-L 12V135AH 341 172 282 288 41.8 75.0 102.0 115.0 135.0 148.0
NP150-12-L 12V150AH 483 170 241 241 44.5 87.0 115.0 130.0 150.0 165.0
NP160-12-L 12V160AH 532 207 214 240 53.4 90.0 122.0 140.0 160.0 176.0
NP180-12-L 12V180AH 532 207 214 240 56.3 105.0 140.0 155.0 180.0 198.0
NP200-12-L 12V200AH 522 240 218 244 61.5 115.0 152.0 172.0 200.0 220.0
NP230-12-L 12V230AH 521 269 203 206 66.0 127.0 172.5 196.0 230.0 250.0
NP240-12-L 12V240AH 521 269 203 206 67.0 135.0 182.0 206.0 240.0 260.0
NP250-12-L 12V250AH 520 269 220 223 76.0 140.0 190.0 215.0 250.0 270.0
Deu
tsch
e P
ow
er E
lect
ron
ics
e.K
.
Po
we
r o
f yo
ur
com
pan
y
VRLA Battery GM Series Thick plate design 10 years design life ABS case(Can be made with FR V0)
Battery
Model Specification
Dimensions(mm) Weight Kg±0.5Kg
(Approx)
Capacity (AH) @ 25 ℃ , 1.75V/Cell
L ±1
W ±1 H1 ±2
H2 ±2
1HR 3HR 5HR 8HR 10HR
GM50-2 2V50AH 161 50 166 166 3.2 30.0 40.0 44.0 48.5 50.0
GM100-2 2V100AH 171 71 205 228 6.7 58.0 75.0 85.0 97.0 100.0
GM150-2 2V150AH 172 102 205 228 9.2 90.0 115.0 130.0 146.0 150.0
GM200-2 2V200AH 173 111 330 365 13.5 120.0 155.0 175.0 194.0 200.0
GM250-2 2V250AH 173 111 330 365 16.0 150.0 190.0 215.0 243.0 250.0
GM300-2 2V300AH 171 151 330 365 18.6 180.0 230.0 257.0 291.0 300.0
GM375-2 2V375AH 171 151 330 365 23.0 225.0 285.0 320.0 364.0 375.0
GM400-2 2V400AH 211 176 330 365 26.4 240.0 310.0 340.0 388.0 400.0
GM450-2 2V450AH 223 187 351 385 33.7 270.0 345.0 385.0 437.0 450.0
GM500-2 2V500AH 241 172 331 365 31.0 310.0 385.0 430.0 485.0 500.0
GM570-2 2V570AH 223 187 350 378 37.0 342.0 430.0 490.0 553.0 570.0
GM600-2 2V600AH 301 175 331 365 40.0 365.0 455.0 515.0 582.0 600.0
GM700-2 2V700AH 301 175 331 365 46.0 420.0 530.0 598.0 678.0 700.0
GM750-2 2V750AH 301 175 331 365 48.0 450.0 570.0 642.0 727.0 750.0
GM800-2 2V800AH 410 175 330 365 52.2 500.0 610.0 685.0 776.0 800.0
GM1000-2 2V1000AH 475 175 328 365 62.2 620.0 765.0 865.0 970.0 1000.0
GM1200-2 2V1200AH 475 175 328 365 75.0 720.0 910.0 1025.0 1165.0 1200.0
GM1250-2 2V1250AH 475 175 328 365 77.0 750.0 945.0 1070.0 1213.0 1250.0
GM1500-2 2V1500AH 401 351 343 382 98.5 950.0 1130.0 1280.0 1445.0 1500.0
GM2000-2 2V2000AH 491 351 343 383 127.0 1250.0 1530.0 1720.0 1940.0 2000.0
GM3000-2 2V3000AH 712 353 341 383 188.5 1800.0 2285.0 2570.0 2910.0 3000.0
GM4000-2 2V4000AH 712 353 341 383 193.5 2400.0 3000.0 3425.0 3860.0 4000.0
Gel Battery GMG Series
Deep cycle Gel design 15 years design life ABS case(can be made with FR V0) Front Terminal design
Battery
Model Specification
Dimensions(mm) Weight
Kg±0.2Kg
(Approx)
Capacity (AH) @ 25 ℃, 1.75V/Cell
L
±1
W
±1
H1
±2
H2
±2 3HR 5HR 10HR 20HR 100HR
NP55-12-FG 12V55AH 277 106 223 223 18.0 40.4 45.7 51.0 55.0 65.0
NP80-12-FG 12V80AH 394 109 286 286 28.0 57.0 65.0 74.0 80.0 90.0
NP100-12-FG 12V100AH 394 109 286 286 35.5 72.0 81.0 94.0 100.0 111.0
NP125-12-FG 12V125AH 551 109 288 288 42.0 94.0 105.0 115.0 125.0 137.0
NP155-12-FG 12V155AH 551 109 288 288 50.0 113.0 129.0 145.0 155.0 170.0
Deu
tsch
e P
ow
er E
lect
ron
ics
e.K
.
Po
we
r o
f yo
ur
com
pan
y
Gel Battery NPG Series
Deep Cycle Gel design 12 years design life ABS case(can be made with FR V0)
Battery
Model Specification
Dimensions(mm) Weight
Kg±0.2Kg
(Approx)
Capacity (AH) @ 25 ℃ , 1.75V/Cell
L
±1
W
±1
H1
±2
H2
±2 3HR 5HR 10HR 20HR 100HR
NP225-6-G 6V225AH 243 188 275 275 33 140.0 155.0 180.0 200.0 220.0
NP18-12-G 12V18AH 181 76 168 168 5.8 12.5 13.5 15.0 16.0 18.2
NP26-12-G 12V26AH 166 126 176 176 10.0 19.0 21.0 24.0 26.0 29.0
NP33-12-G 12V33AH 195 131 151 151 11.0 22.0 24.0 28.0 31.0 35.0
NP40-12-G 12V40AH 198 166 170 170 14.8 29.0 32.0 36.0 40.0 44.0
NP55-12-G 12V55AH 229 138 214 214 19.0 39.0 42.0 50.0 55.0 60.0
NP70-12-G 12V70AH 260 168 214 214 25.5 50.0 54.0 65.0 70.0 76.0
NP80-12-G 12V80AH 260 168 214 214 26.5 55.0 60.0 70.0 80.0 85.0
NP90-12-G 12V90AH 306 168 214 214 30.5 64.0 70.0 81.0 90.0 100.0
NP100-12-G 12V100AH 306 168 214 214 32.5 70.0 75.0 90.0 99.0 105.0
NP110-12-G 12V110AH 326 173 212 217 34.0 78.0 85.0 102.0 110.0 120.0
NP120-12-G 12V120AH 326 173 212 217 36.0 88.0 95.0 110.0 120.0 130.0
NP135-12-G 12V135AH 341 173 281 281 42.5 83.0 90.0 120.0 135.0 140.0
NP150-12-G 12V150AH 482 170 238 238 48.5 106.0 115.0 135.0 150.0 160.0
NP200-12-G 12V200AH 520 238 223 223 66.0 140.0 155.0 180.0 200.0 220.0
NP250-12-G 12V250AH 520 268 220 220 80.5 165.0 180.0 220.0 240.0 260.0
Deu
tsch
e P
ow
er E
lect
ron
ics
e.K
.
Po
we
r o
f yo
ur
com
pan
y
Deu
tsch
e P
ow
er E
lect
ron
ics
e.K
.
Po
we
r o
f yo
ur
com
pan
y
Monitoring & Controlling & Management Software
Power failures and abnormal supply conditions can occur at any time, including when your Network system is
running unattended. When there is a power interruption, the UPS Software broadcasts a warning message to all
workstation users on the network urging them to finish their current tasks. In the event of a lengthy power failure,
the software automatically saves files and gracefully shuts down the operating system after a user-configured time
period or when the UPS batteries are low on energy.
The intelligent software can even notify an off-site systems administrator of the shutdown by paging them through a
modem. Deutsche Power UPS Software provides other useful management functions too, such as scheduling
automatic system boot up and shutdown, monitoring UPS battery condition and logging and analyzing abnormal
utility power conditions.
All Deutsche Power Products are equipped with Smart /Rs232/USB Ports (optional) which are compatible with
commonly supported products and Ports.
Some of the Applications, Devices and Software which can be attached are as follows:-
Software to Monitor and Control RS232 Smart UPS like Online UPS
Software to Monitor and Control Contact Closure DB9 UPS like Line Interactive UPS
A versatile Web-Based SNMP card for UPS
Device for Temperature, Humidity and Water level Sensor
Devices for Web-Based 8 Channel Sensor Collector
Deu
tsch
e P
ow
er E
lect
ron
ics
e.K
.
Po
we
r o
f yo
ur
com
pan
y
Contact Details:-
Head Office :- Germany
Postal address:- D.P Electronics e.K (Deutsche Power Electronics Co. )
Bismarckstr, 55, 64293, Darmstadt , Germany
Email address:- [email protected]
Asia Region Office:- Hong Kong
Postal address:- D.P Electronics e.K (Deutsche Power Electronics Co. )
RM 1701 (057),17/F, HeNan Building, No. 90, Wan Chai, Hong Kong
Email address:- helenlong@[email protected]
www.deutschepower.de
Deu
tsch
e P
ow
er E
lect
ron
ics
e.K
.
Po
we
r o
f yo
ur
com
pan
y