DR Distribution SystemDistribution system for domestic hot water and heating systems.
Danfoss Redan A/S offers a prefabricated solution for domestic hot water and heating systems.
ApplicationDanfoss Redan DR distribution system with manifolds for application on domestic hot water and heating systems with hidden pipe installations. The DR distribution system is prefabricated for implementation with the Danfoss Redan standard district heating substations for single-family houses.
ConstructionThe distribution system will be supplied indi-vidually adapted to the specific application. The distribution system consists of a back plate incl. of mounting brackets for mani-folds as well as connection pipes between district heating substation and manifolds.
AccessoriesThe distribution system can be supplied with Danfoss wireless floor heating control system CF-MC 24 V incl. of 230 V power sup-ply as well as accessories according to re-quirement. Floor heating control and acces-sories can be pre-wired electronically upon request at the factory.
Basic variants - ApplicationsThe DR distribution system is very flexible
and is available in five basic variants. The distribution system is for direct implemen-tation with the Danfoss Redan standard TD, S and VX substations. Please see specifica-tions on the back.
InstallationDue to the very compact design of the dis-tribution system it can be mounted in a 60 or 80 cm standard cupboard, dependent on choice of variant and number of mani-folds. The distributions system is based on a back plate, which, at the initial stage of the building process, is attached directly to the building base. Subsequently the pipes are connected to the manifolds and when the building is finished and protected against theft and right before the system is put into operation, the Danfoss Redan district heating substation can be installed and ad-justed.
Service friendlySuitable piping and placement of the mani-folds as well as consistent use of union nuts to connect pipes to manifolds facilitates the servicing of the distribution system.
ConnectionsThe manifolds are supplied with connection for PEX and/or AluPEX. Please see connection options on the back. AccessoriesThe DR distribution system can be supplied with following accessories: Thermal actua-tor with 10 m cable, pump relay and possi-ble wiring of this, piping for district heating connection. (Please contact our sales de-partment for prices).
VL.KS.S1.02 © Danfoss 09/2007
FEATURES AND BENEFITS
• Prefabricatedforimplementationwiththe Danfoss Redan standard district heating substations for single-family houses
• Individuallyadaptedtothespecificap-plication
• Minimumspacerequiredforinstalla-tion
• Minimumtimerequiredforinstallation
• “Plug&Play”construction
DR Distribution SystemElevated view
Danfoss Redan A/S · District Heating · Sindalsvej 33-35 ·DK-8240 RisskovTel.: +45 87 43 89 43 · Fax: +45 87 43 89 44 · [email protected] · www.redan.danfoss.dk
VL.KS.S1.02 © Danfoss 09/2007 DKDHR
DR Distribution System - Variants: Distribution unit R: For manifolds for radiator circuit. Distribution unit G: For manifolds for floor heating circuit. DistributionunitGR: Formanifoldsforfloorheatingcircuitandformanifoldsforradiatorcircuit.,inkl.offittingsandflexpipeforradiatoroutlet. DistributionunitGI: Formanifoldsforfloorheatingcircuitincl.ofmixingloopwithpumpandthermostatforfloorheating. DistributionunitGRI: Formanifoldsforbothradiatorandfloorheatingcircuit,incl.ofmixingloopwithpumpandthermostatforfloorheating.
Possible combinations of Danfoss Redan district heating substations and distribution units.
Note: Please contact our sales department for possible combinations for DR distribution systems with a combination of manifolds for floor heating and radiator heating.1) Max. width 600 mm (cupboard width 60 cm).2) Max. width 800 mm (cupboard width 80 cm).3) Max. 200 m².
DH
sup
ply
DH
retu
rn
DC
W
Circ
ulat
ion
DH
W
HE
sup
ply
HE
retu
rn
Measurements:Type R, G, GR: H 680 x W 570 x D max. 410 mmTypeGI,GRI: H680xW570xDmax.550mm
Total height, implemented with Danfoss Redan units:TD or S-Unit with DR Distribution System: H 1323 mmVX 2000 or VX with DR Distribution System: H 1676 mmVTD or VS-100/150 l w. DR Distribution System: H 1943/2273 mm(Wall-mounted cylinder solutions)VVX-100/150 l with DR Distribution System: H 2038/2368 mm(Wall-mounted cylinder solutions)
Combinations Heating Domestic hot water
Danfoss Redan unit Direct heating Indirectheating Max. number of connections Max. number of connections
Type DHW principleDistribution
unitFloor heating Radiator Floor heating Radiator
Manifold for floor heating
Manifold for radiators
DCW DHW
TD-UnitSubstation
with instan-taneous water
heater
Types:Akva VitaAkva Lux
Type R x - 101)-162)
101)-162) 101)-162)
S-Unit Type R x - 101)-162)S-Unit Type G x3) 161) -S-Unit Type GR x3) x 8-12 6-10VX 2000/VX Type G x3) 161) -VX 2000/VX Type GR x3) x 8-12 6-10VX 2000/VX TypeGRI x x 8-12 6-10VX 2000/VX TypeGI x 161) -VX 2000/VX Type R x - 101)-162)VTD
Substation with DHW
cylinder
Type:Comfort
Type R x - 101)-162)VTD TypeGI x 161) -VS Type G x3) 161) -VS Type GR x3) x 8-12 6-10VVX-1 / 2 Type R x - 101)-162)VVX 3 Type G x x3) 161) -VVX 3 Type GR x 8-12 6-10VVX-1 / 2 TypeGRI x x 8-12 6-10VVX-1 / 2 TypeGI x 161) -VX Solo
Substation w/o DHW
supply
Type R x - 101)-162)