29
Transcript
Page 1: Dr. Meir Mamraev, DMD,. LLB,. - The Future of Dental Implants Reports/Guided Surgery - Case Stu… · at Cortex dental implants industries LTD. Head of postgraduate training programs
Page 2: Dr. Meir Mamraev, DMD,. LLB,. - The Future of Dental Implants Reports/Guided Surgery - Case Stu… · at Cortex dental implants industries LTD. Head of postgraduate training programs

Dr. Meir Mamraev, DMD,. LLB,.Graduated from Dental school of Iasi University in 1992 and Law

school of Ono College in 2005.One of the founders of Cortex company. Senior Vice

President of research and Developmentat Cortex dental implants industries LTD.

Head of postgraduate training programs and academical activities of Cortex.

Worldwide lecturer as well as an owner of a private dental practice in Tel-Aviv, Israel.

[email protected]

Page 3: Dr. Meir Mamraev, DMD,. LLB,. - The Future of Dental Implants Reports/Guided Surgery - Case Stu… · at Cortex dental implants industries LTD. Head of postgraduate training programs

CASE 1............................................3-7

CASE 2............................................8-11

CASE 3............................................12-18

CASE 4............................................19-22

CASE 5............................................23-27

INDEX

Page 4: Dr. Meir Mamraev, DMD,. LLB,. - The Future of Dental Implants Reports/Guided Surgery - Case Stu… · at Cortex dental implants industries LTD. Head of postgraduate training programs

3

CASE 1 (Dr. Meir Mamraev – Israel)

Diagnostics

Age: 59

Gender: Female

Periimplantitis: 27

Roots #13, #15, #11, #21, #22, #23, #24 deep caries and fractured crowns with no option for rehabilitation. General Health: good

Digital files: CBCT scan & Digital impression

Page 5: Dr. Meir Mamraev, DMD,. LLB,. - The Future of Dental Implants Reports/Guided Surgery - Case Stu… · at Cortex dental implants industries LTD. Head of postgraduate training programs

4

CBCT SCAN

MODEL STL

PANORAMIC X-RAY

CASE 1

Page 6: Dr. Meir Mamraev, DMD,. LLB,. - The Future of Dental Implants Reports/Guided Surgery - Case Stu… · at Cortex dental implants industries LTD. Head of postgraduate training programs

5

Treatment Plan

1. Prosthetically driven virtual implant planning- 3Shape Implant Studio: Safety Zone – apical distance – 2.0 mm

Safety Zone – radical distance – 1.5 mm

Position #15: Ø3.8 / 11.5mm – Dynamix Conical

Position #12: Ø3.8 / 11.5mm – Dynamix Conical

Position #22: Ø3.8 / 11.5mm – Dynamix Conical

Position #23: Ø3.8 / 11.5mm – Dynamix Conical

Position #27: Ø3.8 / 11.5mm – Dynamix Conical

CASE 1

Page 7: Dr. Meir Mamraev, DMD,. LLB,. - The Future of Dental Implants Reports/Guided Surgery - Case Stu… · at Cortex dental implants industries LTD. Head of postgraduate training programs

6

2. Guided Surgery - Cortex Guided Surgery Kit + Cortex Guiding sleeves

Teeth extraction #13, #14, #11, #21, #22, #23, #24, implant #27 removal Implant placement: #12, #15, #22, #23, #27 Immediate full arch temporization, including existing implants #16, #17, #25, #26

3. Surgical guide

4. Immediate temporization with PMMA total bridge on Multi-units. Implant #27 was not loaded. Operation

Operation Date: 23/10/2018 Flapless procedure Execution of the treatment plan

CASE 1

Page 8: Dr. Meir Mamraev, DMD,. LLB,. - The Future of Dental Implants Reports/Guided Surgery - Case Stu… · at Cortex dental implants industries LTD. Head of postgraduate training programs

7

Clinical Follow-Up including X-ray and dates

Conclusion There were no signs of peri-implantitis around the implants on none of the follow up OP after implant placement, no fibrosis, and no bone loss value. The bone integration around the implant progressed according to plan without fatty infiltration, granuloma, etc.

14 12

22

27 25

CASE 1

Page 9: Dr. Meir Mamraev, DMD,. LLB,. - The Future of Dental Implants Reports/Guided Surgery - Case Stu… · at Cortex dental implants industries LTD. Head of postgraduate training programs

8

CASE 2 (Dr. Meir Mamraev – Israel)

Diagnostics

Age: 77

Gender: Female

Teeth #44, #45, #46, #47 are missing

General Health: good

Digital files: CBCT scan & Digital impression

Page 10: Dr. Meir Mamraev, DMD,. LLB,. - The Future of Dental Implants Reports/Guided Surgery - Case Stu… · at Cortex dental implants industries LTD. Head of postgraduate training programs

9

Treatment Plan

1. Prosthetically driven virtual implant planning - 3Shape Implant Studio Safety Zone – apical distance – 2.0 mm

Safety Zone – radical distance – 1.5 mm

Position #44: Ø3.8 / 13mm – Dynamix Conical Position #46: Ø3.8 / 10mm – Dynamix Conical

CBCT SCAN

MODEL STL

CASE 2

Page 11: Dr. Meir Mamraev, DMD,. LLB,. - The Future of Dental Implants Reports/Guided Surgery - Case Stu… · at Cortex dental implants industries LTD. Head of postgraduate training programs

10

Position #47: Ø4.2 / 8mm – Dynamix Conical

2. Guided Surgery- Cortex Guided Surgery Kit + Cortex Guiding sleeves 3. Implant placement position #44, #46, #47 4. Surgical guide

Operation

Operation Date: 21/10/2018

Flapless procedure Guided surgery for implant placement 44, 46, 47

CASE 2

Page 12: Dr. Meir Mamraev, DMD,. LLB,. - The Future of Dental Implants Reports/Guided Surgery - Case Stu… · at Cortex dental implants industries LTD. Head of postgraduate training programs

11

Clinical Follow-Up including X-ray and dates

Conclusion There were no signs of peri-implantitis around the implants on none of the follow up OP after implant placement, no fibrosis, and no bone loss value. The bone integration around the implant progressed according to plan without fatty infiltration, granuloma, etc.

Implant 44

Implant 47

Implant 46

CASE 2

Page 13: Dr. Meir Mamraev, DMD,. LLB,. - The Future of Dental Implants Reports/Guided Surgery - Case Stu… · at Cortex dental implants industries LTD. Head of postgraduate training programs

12

CASE 3 (Dr. Meir Mamraev – Israel)

Diagnostics

Age: 64

Gender: Male

Fully edentulous lower case

Old removable denture

General Health: good

Digital files: Dual scanning protocol:

CBCT of denture with 3D markers

CBCT of the same denture inside patients’ mouth

Page 14: Dr. Meir Mamraev, DMD,. LLB,. - The Future of Dental Implants Reports/Guided Surgery - Case Stu… · at Cortex dental implants industries LTD. Head of postgraduate training programs

13

CASE 3 Treatment Plan

1. Prosthetically driven virtual implant planning- 3Shape Implant Studio Safety Zone – apical distance – 2.0 mm

Safety Zone – radical distance – 1.5 mm

Position #32: Ø3.8 / 11.5mm – Dynamix Conical Position #33: Ø3.8 / 16mm – Dynamix Conical

CBCT of the denture inside patients’ mouth CBCT of denture with 3D markers

CASE 3

Page 15: Dr. Meir Mamraev, DMD,. LLB,. - The Future of Dental Implants Reports/Guided Surgery - Case Stu… · at Cortex dental implants industries LTD. Head of postgraduate training programs

14

Position #42: Ø3.8 / 11.5mm – Dynamix Conical Position #43: Ø3.8 / 16mm – Dynamix Conical

2. Guided Surgery- Cortex Guided Surgery Kit + Cortex Guiding sleeve Implant placement in positions: #32, #33, #42, #43 + 3 fixation pins for guide stabilization. Immediate temporization- total PMMA bridge fixed on Angulated multi units.

CASE 3

Page 16: Dr. Meir Mamraev, DMD,. LLB,. - The Future of Dental Implants Reports/Guided Surgery - Case Stu… · at Cortex dental implants industries LTD. Head of postgraduate training programs

15

3. Surgical guide

PMMA bridge, Digital model Analog & Surgical Guide Operation

Operation Date: 23/10/2018

Raised flap procedure Cortex Guided Surgery kit Guided implant placement in position: #32, #33, #42, #43 Manual bone straitening & reduction Guided bone milling as a preparation for angulated multi-unit placement Immediate temporization with PMMA bridge All components, including the temporary bridge, were prepared in advance. The prosthetic solution was delivered on a Digital model

4. CAD CAM prosthetic solution - Virtual Design

CASE 3

Page 17: Dr. Meir Mamraev, DMD,. LLB,. - The Future of Dental Implants Reports/Guided Surgery - Case Stu… · at Cortex dental implants industries LTD. Head of postgraduate training programs

16

Clinical documentation:

Checking guide fit & stability Fixation pins

Site preparation Implant placement Bone reduction Guided bone mill

CASE 3

Page 18: Dr. Meir Mamraev, DMD,. LLB,. - The Future of Dental Implants Reports/Guided Surgery - Case Stu… · at Cortex dental implants industries LTD. Head of postgraduate training programs

17

Multi-unit placement Titanium sleeves placement Passive fit of the prosthesis Final result

CASE 3

Page 19: Dr. Meir Mamraev, DMD,. LLB,. - The Future of Dental Implants Reports/Guided Surgery - Case Stu… · at Cortex dental implants industries LTD. Head of postgraduate training programs

18

Clinical Follow-Up including X-ray and dates

Conclusion There were no signs of peri-implantitis around the implants on none of the follow up OP after implant placement, no fibrosis, and no bone loss value. The bone integration around the implant progressed according to plan without fatty infiltration, granuloma, etc.

Implant 44 Implant 42

Implant 32 Implant 34

CASE 3

Page 20: Dr. Meir Mamraev, DMD,. LLB,. - The Future of Dental Implants Reports/Guided Surgery - Case Stu… · at Cortex dental implants industries LTD. Head of postgraduate training programs

19

CASE 4 (Dr. Meir Mamraev – Israel)

Diagnostics

Age: 56

Gender: Female

Teeth #46, #47 are missing

General Health: good

Digital files: CBCT scan & Digital impression

Page 21: Dr. Meir Mamraev, DMD,. LLB,. - The Future of Dental Implants Reports/Guided Surgery - Case Stu… · at Cortex dental implants industries LTD. Head of postgraduate training programs

20

CASE 4 Treatment Plan

1. Prosthetically driven virtual implant planning- 3Shape Implant Studio Safety Zone – apical distance – 2.0 mm

Safety Zone – radical distance – 1.5 mm

Position #46: Ø3.8 / 10mm – Dynamix Conical Position #47: Ø3.8 / 8mm – Dynamix Conical

CBCT SCAN MODEL STL

CASE 4

Page 22: Dr. Meir Mamraev, DMD,. LLB,. - The Future of Dental Implants Reports/Guided Surgery - Case Stu… · at Cortex dental implants industries LTD. Head of postgraduate training programs

21

CASE 4 2. Guided Surgery- Cortex Guided Surgery Kit + Cortex Guiding sleeve

Implant placement in positions: #46, #47.

3. Surgical guide

Operation

Operation Date: 20/09/2018 Raised flap procedure/ flapless procedure

Guided surgery for implant placement 46

CASE 4

Page 23: Dr. Meir Mamraev, DMD,. LLB,. - The Future of Dental Implants Reports/Guided Surgery - Case Stu… · at Cortex dental implants industries LTD. Head of postgraduate training programs

22

CASE 4

Clinical Follow-Up including X-ray and dates

Conclusion There were no signs of peri-implantitis around the implants on none of the follow up OP after implant placement, no fibrosis, and no bone loss value. The bone integration around the implant progressed according to plan without fatty infiltration, granuloma, etc.

Implant 46 Implant 47

CASE 4

Page 24: Dr. Meir Mamraev, DMD,. LLB,. - The Future of Dental Implants Reports/Guided Surgery - Case Stu… · at Cortex dental implants industries LTD. Head of postgraduate training programs

23

CASE 5 (Dr. Meir Mamraev – Israel)

Diagnostics

Age: 70

Gender: Female

Fully edentulous upper case

Removable denture

General Health: good

Digital files: dual scan technique

Page 25: Dr. Meir Mamraev, DMD,. LLB,. - The Future of Dental Implants Reports/Guided Surgery - Case Stu… · at Cortex dental implants industries LTD. Head of postgraduate training programs

24

CASE 5 Treatment Plan

1. Prosthetically driven virtual implant planning- 3Shape Implant Studio Safety Zone – apical distance – 2.0 mm

Safety Zone – radical distance – 1.5 mm

Position #12: Ø3.8 / 13mm – Dynamix Conical Position #13: Ø3.8 / 13mm – Dynamix Conical

CBCT of the denture with 3D markers inside

the patients mouth CBCT of the denture with 3D markers

CASE 5

Page 26: Dr. Meir Mamraev, DMD,. LLB,. - The Future of Dental Implants Reports/Guided Surgery - Case Stu… · at Cortex dental implants industries LTD. Head of postgraduate training programs

25

Position #22: Ø3.8 / 13mm – Dynamix Conical Position #16: Ø3.8 / 16mm – Dynamix Conical Position #23: Ø3.8 / 13mm – Dynamix Conical Position #26: Ø3.8 / 16mm – Dynamix Conical

CASE 5

Page 27: Dr. Meir Mamraev, DMD,. LLB,. - The Future of Dental Implants Reports/Guided Surgery - Case Stu… · at Cortex dental implants industries LTD. Head of postgraduate training programs

26

2. Guided Surgery- Cortex Guided Surgery Kit + Cortex Guiding sleeve

3. Surgical guide with three fixation pins

Operation

Operation Date: 19/12/2018 Flapless procedure

Guided surgery for implant placement in position #16, #13, #12, #22, #23, #26

CASE 5

Page 28: Dr. Meir Mamraev, DMD,. LLB,. - The Future of Dental Implants Reports/Guided Surgery - Case Stu… · at Cortex dental implants industries LTD. Head of postgraduate training programs

27

Clinical Follow-Up including X-ray and dates

Conclusion There were no signs of peri-implantitis around the implants on none of the follow up OP after implant placement, no fibrosis, and no bone loss value. The bone integration around the implant progressed according to plan without fatty infiltration, granuloma, etc.

CASE 5

Page 29: Dr. Meir Mamraev, DMD,. LLB,. - The Future of Dental Implants Reports/Guided Surgery - Case Stu… · at Cortex dental implants industries LTD. Head of postgraduate training programs

[email protected] www.cortex-dental.com