+ All Categories
Home > Documents > Dr Vladimir Hotinski BDSc MSD OVER DENTURE … OVER...OVER DENTURE TECHNIQUES COURSE TOPICS TO BE...

Dr Vladimir Hotinski BDSc MSD OVER DENTURE … OVER...OVER DENTURE TECHNIQUES COURSE TOPICS TO BE...

Date post: 09-Jun-2020
Category:
Upload: others
View: 2 times
Download: 0 times
Share this document with a friend
2
Friday 27th March 2015 MIDLAND, Perth WA VENUE Concept Dental Training Centre 18 Stafford St, MIDLAND WA, 6056 DATE Friday 27th March 2015 TIME 8:00am Registration 8:30 - 5:30pm Lecture and Workshop COST $895.00 including lunch, morning/afternoon tea All materials and instruments for workshops also included COURSE ENQUIRIES: Bruce McDowell Phone: 0417 977 501 E-mail: [email protected] at Henry Schein Halas Perth Office REGISTRATION ENQUIRIES: Gayle Jones Phone: 0449 904 806 E-mail: [email protected] at Henry Schein Halas Perth Office HSH2048 PRESENTER Dr Vladimir Hotinski BDSc MSD Dr Vladimir ‘Bob’ Hotinski completed his undergraduate dental degree at the University of Western Australia in 1969 and his specialist Prosthodontic training at the University of Indiana in 1978. He has established a successful full time specialist private practice in the Hills and since 1980 Bob has also been involved in teaching at the University of Western Australia in varying capacities. He has lectured extensively and conducted courses both nationally and internationally and has also been involved in developing programmes and lectures at the Dental School, University of Phnom Penh, Cambodia. Bob has been a Prosthodontic clinical supervisor for the Adelaide University Masters Course. Bob’s passion is training and education in conjunction with clinical practice: his key interests are the interdisciplinary management of complex adult dentitions, aesthetically challenging cases, implants and CEREC technology. WHEN & WHERE 7.5 CPD HOURS BAR ATTACHMENT IMPLANT ATTACHMENT ONE DAY OVER DENTURE TECHNIQUES COURSE
Transcript
Page 1: Dr Vladimir Hotinski BDSc MSD OVER DENTURE … OVER...OVER DENTURE TECHNIQUES COURSE TOPICS TO BE COVERED: 1. Planning and Placement Parameters (treatment planning) 2. Prosthetic Considerations

F r i day 27th March 2015 MIDLAND , Pe r th WA

VENUEConcept Dental Training Centre18 Stafford St, MIDLAND WA, 6056 DATEFriday 27th March 2015 TIME8:00am Registration8:30 - 5:30pm Lecture and Workshop COST$895.00 including lunch,morning/afternoon teaAll materials and instrumentsfor workshops also included COURSE ENQUIRIES:Bruce McDowellPhone: 0417 977 501E-mail: [email protected] Henry Schein Halas Perth Office REGISTRATION ENQUIRIES:Gayle JonesPhone: 0449 904 806E-mail: [email protected] Henry Schein Halas Perth Office

HSH2048

PRESENTERDr Vladimir Hotinski BDSc MSD

Dr Vladimir ‘Bob’ Hotinski completed his undergraduate dental degree at the University of Western Australia in 1969 and his specialist Prosthodontic training at the University of Indiana in 1978. He has established a successful full time specialist private practice in the Hills and since 1980 Bob has also been involved in teaching at the University of Western Australia in varying capacities. He has lectured extensively and conducted courses both nationally and internationally and has also been involved in developing programmes and lectures at the Dental School, University of Phnom Penh, Cambodia. Bob has been a Prosthodontic clinical supervisor for the Adelaide University Masters Course. Bob’s passion is training and education in conjunction with clinical practice: his key interests are the interdisciplinary management of complex adult dentitions, aesthetically challenging cases, implants and CEREC technology.

WHEN & WHERE

7.5 CPD HOURS

BAR ATTACHMENT

LOCATOR®. THE SIMPLE SOLUTION.

With the growing demographic of edentulous patients, the market opportunity for

implant-retained overdentures as a treatment model has never been more viable and

important. Easy to insert and remove by your patients, ZEST Anchors’ self-aligning

LOCATOR Overdenture Attachments are designed with customizable levels of retention,

lowest vertical profi le, and exceptional durability. Most important is its innovative

ability to pivot, which increases the attachment’s resiliency and tolerance for the high

mastication forces an attachment must withstand. This streamlined performance leads

to fewer problems, increased productivity and long-term satisfaction. Your patients can

rest assured that they are getting the best overdenture attachment connection possible.

IMPLANT ATTACHMENTThe LOCATOR Implant Attachment is the premier system for

implant-retained overdentures. According to recent studies,

a two implant-retained overdenture restoration is considered

the new minimum standard of care for edentulous patients.

BAR ATTACHMENTWhen a case calls for a bar attachment, the LOCATOR Bar

Attachment provides the self-aligning feature, superb retention,

long-lasting durability and low profi le design. It also offers

three options for the fabrication of a resilient attachment on

an implant-supported cast alloy or milled titanium bar.

ROOT ATTACHMENTThe LOCATOR Root Attachment is a supra-radicular design

that gives you the choice of a straight post and two angles

(10 and 20 degrees) to accommodate divergent roots and a

special cast-to version.

LOCATOR®. THE SIMPLE SOLUTION.

With the growing demographic of edentulous patients, the market opportunity for

implant-retained overdentures as a treatment model has never been more viable and

important. Easy to insert and remove by your patients, ZEST Anchors’ self-aligning

LOCATOR Overdenture Attachments are designed with customizable levels of retention,

lowest vertical profi le, and exceptional durability. Most important is its innovative

ability to pivot, which increases the attachment’s resiliency and tolerance for the high

mastication forces an attachment must withstand. This streamlined performance leads

to fewer problems, increased productivity and long-term satisfaction. Your patients can

rest assured that they are getting the best overdenture attachment connection possible.

IMPLANT ATTACHMENTThe LOCATOR Implant Attachment is the premier system for

implant-retained overdentures. According to recent studies,

a two implant-retained overdenture restoration is considered

the new minimum standard of care for edentulous patients.

BAR ATTACHMENTWhen a case calls for a bar attachment, the LOCATOR Bar

Attachment provides the self-aligning feature, superb retention,

long-lasting durability and low profi le design. It also offers

three options for the fabrication of a resilient attachment on

an implant-supported cast alloy or milled titanium bar.

ROOT ATTACHMENTThe LOCATOR Root Attachment is a supra-radicular design

that gives you the choice of a straight post and two angles

(10 and 20 degrees) to accommodate divergent roots and a

special cast-to version.

IMPLANT ATTACHMENT

ONE DAY OVER DENTURE TECHNIQUES COURSE

Page 2: Dr Vladimir Hotinski BDSc MSD OVER DENTURE … OVER...OVER DENTURE TECHNIQUES COURSE TOPICS TO BE COVERED: 1. Planning and Placement Parameters (treatment planning) 2. Prosthetic Considerations

TOPICS TO BE COVERED:

1. Planning and Placement Parameters

(treatment planning)

2. Prosthetic Considerations

3. Bars, Balls or Locators

4. Indications and Contra-indications

5. Complications

6. Practical Application:

1. Placement of Implants and

Over-denture abutments

2. Impression Techniques

3. Chairside pick up techniques

for attachments

AIM: TO PROVIDE THE GENERAL PRACTITIONER WITH THE FUNDAMENTALS OF IMPLANT OVER DENTURE PLANNING AND RESTORATIVE PROTOCOLS FOR DAILY PRACTICE.

ONE DAY OVER DENTURE TECHNIQUES COURSE

pIvotIng technoLogy the Locator Male pivots in its permanent denture cap for

a genuine resilient connection of the prosthesis without any

resulting loss of retention. the male remains in static contact

with the female socket while the denture cap has a full range

of rotational movement over the male.

eXceptIonaL duraBILIty the Locator attachment has twice the amount of retention

surface area than other attachments available. the unique dual

retention innovation that includes inside and outside retention

ensures long-lasting performance, as shown by an independent

laboratory test comparing the Locator to the stern era®

Implant attachment during 60,000 cycles of function.*

seLf-aLIgnIng desIgnthe self-aligning feature of the Locator attachment allows

a patient to easily seat their overdenture without the need

for accurate alignment, and without causing damage to the

attachment components. this self-aligning feature also increases

the longevity of the Locator. patients can really bite their

dentures into place without harming the attachments.

Locator. the sIMpLe soLutIon. one systeM, MuLtIpLe BenefIts.

With the growing demographic of edentulous patients, the market opportunity for

implant-retained overdentures as a treatment model has never been more viable and

important. easy to insert and remove by your patients, Zest anchors’ self-aligning

Locator overdenture attachments are designed with customizable levels of retention,

lowest vertical profile, and exceptional durability. Most important is its innovative

ability to pivot, which increases the attachment’s resiliency and tolerance for the high

mastication forces an attachment must withstand. this streamlined performance leads

to fewer problems, increased productivity and long-term satisfaction. your patients can

rest assured that they are getting the best overdenture attachment connection possible.

IMpLant attachMentthe Zest Locator Implant attachment is the premier system

for implant-retained overdentures. according to recent studies,

a two implant-retained overdenture restoration is considered

the new minimum standard of care for edentulous patients.

60k

40k

20k

50k

30k

10k

Locator Attachment

60,000 Cycles

Stern ERA Attachments2,000 Cycles

*Delsen Testing Laboratories

Bar attachMentWhen a case calls for a bar attachment, the Zest Locator

Bar attachment provides the self-aligning feature, superb

retention, long-lasting durability and low profile design. It also

offers three options for the fabrication of a resilient attachment

on an implant-supported cast alloy or milled titanium bar.

root attachMent the Locator root attachment is a supra-radicular design

that gives you the choice of a straight post and two angles

(10 and 20 degrees) to accommodate divergent roots and a

special cast-to version.

LoWest vertIcaL heIghtthe Locator attachment is designed to reduce the height of

attachment and abutment on all brands of endosseous implants.

With a total attachment height of only 3.17mm (male plus 1mm

collar abutment) for an externally hexed implant, the Locator

saves a minimum of 1.68mm to 3.05mm of interocclusal space

compared to other implant overdenture attachments.

EDS6.22mm

Locator3.17mm

ERA 4.85mm


Recommended