1
THERMAL BARRIER THERMAL BARRIER TITLE: DRAWN BY: SOPREMA TECHNICAL SUPPORT, GGALLOWAY NO.: DATE: REVISION: DATE: 9.8.2015 SCALE: NTS DRAWING NUMBER: US.RSBS.07.03a 2 PLY SBS MEMBRANE, INSULATED ROOF DRAIN WITH SOFT METAL FLASHING USAGE OF THIS DETAIL IS GOVERNED BY THE TERMS OF SERVICE FOR SOPREMA DETAILS. PLEASE CONSULT THESE TERMS OF SERVICE PRIOR TO UTILIZING THIS DRAWING. US CORPORATE ADDRESS 310 QUADRAL DRIVE WADSWORTH, OHIO 44281 www.soprema.us Tel:330.334.0066 WI LLI AM GRANT GALLOWAY PROJECT: DRAWING MUST BE VIEWED IN ADOBE READER TO ENABLE CUSTOM LAYERING NOTES: 1. SOPREMA DETAIL DRAWINGS: REFER TO SOPREMA AND OTHER RELATED PUBLISHED DOCUMENTATION, PRODUCT DATA SHEETS (PDS) AND SAFETY DATA SHEETS (SDS) FOR ADDITIONAL INFORMATION. ALL DETAIL DRAWINGS AND RELATED INSTALLATION GUIDELINES ARE PROVIDED BY SOPREMA FOR THE SOLE PURPOSE OF ISSUING A SOPREMA WARRANTY. ACCORDINGLY, THE DETAIL DRAWINGS ARE NOT OFFERED, AND SHOULD NOT BE CONSIDERED, AS A SUBSTITUTE FOR PROFESSIONAL DESIGN SERVICES. 2. HOT WORK: THE CONTRACTOR IS RESPONSIBLE FOR DETERMINING APPROPRIATE CONDITIONS TO UTILIZE HEAT-WELDING EQUIPMENT. REFER TO THE NRCA CERTA RECOMMENDATIONS, LOCAL CODES AND BUILDING OWNER'S REQUIREMENTS FOR HOT WORK OPERATIONS. 3. PRIMER: WHERE NOT SHOWN OR INDICATED ON DETAIL DRAWINGS, REFER TO MATERIAL PRODUCT DATA SHEETS FOR PRIMER APPLICATION REQUIREMENTS. BASE PLY DRAIN BOWL RECEIVER AND WOOD BLOCKING AS REQUIRED 30" X 30" SOFT METAL FLASHING PRIMED ON BOTH SIDES AND SET IN A BED OF SOPRAMASTIC SBS MASTIC, FORM SPECIFIED SOFT METAL TO DRAIN BOWL AS SHOWN POLYESTER REINFORCED FLASHING BASE PLY CAP SHEET EXTEND FLASHING BASE PLY A MINIMUM OF 3" BEYOND SOFT METAL FLASHING ROOF DRAIN BOWL (OTHER PLUMBING COMPONENTS NOT SHOWN) COVERBOARD BASE SHEET DECK DECK DECK DECK DECK DECK DECK DECK ROOF DRAIN BOWL (OTHER PLUMBING COMPONENTS NOT SHOWN) TAPERED INSULATION SUMP AROUND PRIMARY DRAINS FASTEN BASE PLY AROUND DRAIN FLASHING AT A MAXIMUM OF 12" O.C. EXTEND FLASHING BASE PLY A MINIMUM OF 3" BEYOND FASTENER PLATE BASE SHEET/ANCHOR SHEET VAPOR RETARDER/AIR BARRIER INSULATION INSULATION INSULATION THERMAL BARRIER INSULATION
Transcript
Page 1: DRAWING MUST BE VIEWED IN ADOBE READER TO ENABLE CUSTOM …€¦ · 30" x 30" soft metal flashing primed on both sides and set in a bed of sopramastic sbs mastic, form specified soft

THERMAL BARRIERTHERMAL BARRIER

TITLE:

DRAWN BY: SOPREMA TECHNICAL SUPPORT, GGALLOWAY

NO.: DATE:REVISION:

DATE: 9.8.2015

SCALE: NTS

DRAWING NUMBER:

US.RSBS.07.03a2 PLY SBS MEMBRANE, INSULATED

ROOF DRAIN WITH SOFT METAL FLASHING

USAGE OF THIS DETAIL IS GOVERNED BY THE TERMS OF SERVICE FOR SOPREMA DETAILS.PLEASE CONSULT THESE TERMS OF SERVICE PRIOR TO UTILIZING THIS DRAWING.

US CORPORATE ADDRESS310 QUADRAL DRIVE

WADSWORTH, OHIO 44281www.soprema.usTel:330.334.0066

W I L L I A M G R A N T G A L L O W A YPROJECT:

DRAWING MUST BE VIEWED IN ADOBE READER TO ENABLE CUSTOM LAYERING

NOTES:1. SOPREMA DETAIL DRAWINGS: REFER TO SOPREMA AND OTHER RELATED PUBLISHED DOCUMENTATION, PRODUCT DATA SHEETS (PDS) AND SAFETY DATA SHEETS (SDS) FOR ADDITIONAL

INFORMATION. ALL DETAIL DRAWINGS AND RELATED INSTALLATION GUIDELINES ARE PROVIDED BY SOPREMA FOR THE SOLE PURPOSE OF ISSUING A SOPREMA WARRANTY. ACCORDINGLY, THEDETAIL DRAWINGS ARE NOT OFFERED, AND SHOULD NOT BE CONSIDERED, AS A SUBSTITUTE FOR PROFESSIONAL DESIGN SERVICES.

2. HOT WORK: THE CONTRACTOR IS RESPONSIBLE FOR DETERMINING APPROPRIATE CONDITIONS TO UTILIZE HEAT-WELDING EQUIPMENT. REFER TO THE NRCA CERTA RECOMMENDATIONS, LOCALCODES AND BUILDING OWNER'S REQUIREMENTS FOR HOT WORK OPERATIONS.

3. PRIMER: WHERE NOT SHOWN OR INDICATED ON DETAIL DRAWINGS, REFER TO MATERIAL PRODUCT DATA SHEETS FOR PRIMER APPLICATION REQUIREMENTS.

BASE PLY

DRAIN BOWL RECEIVERAND WOOD BLOCKING

AS REQUIRED

30" X 30" SOFT METAL FLASHING PRIMEDON BOTH SIDES AND SET IN A BED OF

SOPRAMASTIC SBS MASTIC,FORM SPECIFIED SOFT METAL

TO DRAIN BOWL AS SHOWN

POLYESTER REINFORCED FLASHING BASE PLY

CAP SHEET

EXTEND FLASHING BASE PLYA MINIMUM OF 3" BEYONDSOFT METAL FLASHING

ROOF DRAIN BOWL (OTHER PLUMBINGCOMPONENTS NOT SHOWN)

COVERBOARD

BASE SHEET

DECKDECKDECKDECKDECKDECKDECKDECK

ROOF DRAIN BOWL (OTHER PLUMBINGCOMPONENTS NOT SHOWN)

TAPERED INSULATION SUMPAROUND PRIMARY DRAINS

FASTEN BASE PLY AROUND DRAINFLASHING AT A MAXIMUM OF 12" O.C.

EXTEND FLASHING BASE PLY A MINIMUMOF 3" BEYOND FASTENER PLATE

BASE SHEET/ANCHOR SHEET

VAPOR RETARDER/AIR BARRIER

INSULATION

INSULATION

INSULATION

THERMAL BARRIER

INSULATION