0615 2030008793 1 A. INSPECTION Inspect the carton and water cooler for evidence of rough handling and concealed damage. Damage claims should be filed with the carrier. B. TO PUT WATER COOLER AND FOUNTAIN INTO SERVICE 1. NOTE: Provincial and local plumbing codes may prohibit use of saddle taping valves for water line connection in some applications. All connections must conform to applicable plumbing codes. 2. Locate and install plumbing and electrical service if required, in accordance with the Rough-in Drawing. Filter units have additional instructions on a label inside the access panel. Read these before installing unit. 3. FLUSH BUILDING WATER SUPPLY LINE BEFORE INSTALLING UNIT. 4. Install unit on the wall hanger. Wall hanger is shipped fastened to the back of the unit. 5. Install a trap in the waste line and a shut off valve in the water supply line. An in-line strainer is furnished in the “Water Supply” tube. Connect the “Water Supply” tube to the shut off valve. This connection should not be a solder joint or flare connec- tion to allow access to the strainer for service. To ease removal of the strainer, a sheet metal screw may be lightly threaded into the open end. When the unit has an internal waste trap, the trap should be wrapped with the insulating tape to prevent sweating. Use of the 1 3/4" diameter knockout for a waste line is not recommended because of a potential conflict with ADA* toe space clearance requirements. Check your local building code inspector for approval. 6. Rotate the fan blade by hand to see that it is free of obstructions. 7. Check the available power supply against the water cooler data plate to assure the correct electrical service. Plug power supply cord into wall outlet. The rear most 1 3/8" diameter knockout in the frame bottom is for an externally located electrical supply. Make sure the knockout hold edge is smooth and free of any burrs. Use of a Heyco bushing #2184 in the knocked out hole is recommended in order to prevent damage to the service cord and to close up excess opening around the cord. Route the cord so it does not interfere with ADA* space requirements. 8. To fill cold water tank on water cooler versions, open water supply line shut-off and push any one of the front or side pushbuttons to allow water to flow to the bubbler. On the EE model, actuate the solenoid by holding one hand approximately 3" from the infrared sensor. Run water until stream free of bubbles. 9. To Adjust Bubbler: a) All Pushbutton models are equipped with a Cartridge Regulator. The KEP8AC and KEPAC have a slot in the shelf below the Pushbuttons. Insert a screwdriver in the slot to adjust regulator. Turn adjustment clockwise to increase stream height. To ac- cess the KEPV8AC adjustment, remove the Bezel and Button from the front of the cooler. b) Electric Eye (EE) models have a Regulator built into the the Bubbler. If adjustment is needed, insert a 5/64" wrench approxi- mately 1 1/8" into the bubbler nozzle opening until it bottoms out and is seated in an adjust screw. Turn the adjust screw clockwise to reduce stream height or counter clockwise to increase the height. Note: less than one turn is required to go from a closed to a wide open flow. Do not over tighten the adjuster in the closed position as stripping the hex impression in the adjust screw may result. Turn the adjuster 1/16 of a turn at a time. 10. On electic eye equipped models, place and then hold hand approximately 3" from the sensor to actuate the solenoid valve. After approximately 30 seconds run time, the sensor will automatically shut off the solenoid valve. To reactivate, move hand away for an instant and then again place it in front of the sensor. DRINKING FOUNTAIN INSTALLATION For All KEP( )AC-EBF Series Combination Drinking Fountains with Electronic Sports Bottle Filler
Transcript
Page 1: DRINKING FOUNTAIN INSTALLATION...0615 2030008793 5 SECTION 1: GETTING STARTED WHAT’S INCLUDED? 1.op cap T 2. 38" of 1/4 OD plastic tubing with 19" of sponge tubing insulation 3.

0615 2030008793 1

A. INSPECTIONInspect the carton and water cooler for evidence of rough handling and concealed damage. Damage claims should be filed with the carrier.

B. TO PUT WATER COOLER AND FOUNTAIN INTO SERVICE1. NOTE: Provincial and local plumbing codes may prohibit use of saddle taping valves for water line connection in some

applications. All connections must conform to applicable plumbing codes.

2. Locate and install plumbing and electrical service if required, in accordance with the Rough-in Drawing. Filter units have additional instructions on a label inside the access panel. Read these before installing unit.

3. FLUSH BUILDING WATER SUPPLY LINE BEFORE INSTALLING UNIT.

4. Install unit on the wall hanger. Wall hanger is shipped fastened to the back of the unit.

5. Install a trap in the waste line and a shut off valve in the water supply line. An in-line strainer is furnished in the “Water Supply” tube. Connect the “Water Supply” tube to the shut off valve. This connection should not be a solder joint or flare connec-tion to allow access to the strainer for service. To ease removal of the strainer, a sheet metal screw may be lightly threaded into the open end. When the unit has an internal waste trap, the trap should be wrapped with the insulating tape to prevent sweating. Use of the 1 3/4" diameter knockout for a waste line is not recommended because of a potential conflict with ADA* toe space clearance requirements. Check your local building code inspector for approval.

6. Rotate the fan blade by hand to see that it is free of obstructions.

7. Check the available power supply against the water cooler data plate to assure the correct electrical service. Plug power supply cord into wall outlet. The rear most 1 3/8" diameter knockout in the frame bottom is for an externally located electrical supply. Make sure the knockout hold edge is smooth and free of any burrs. Use of a Heyco bushing #2184 in the knocked out hole is recommended in order to prevent damage to the service cord and to close up excess opening around the cord. Route the cord so it does not interfere with ADA* space requirements.

8. To fill cold water tank on water cooler versions, open water supply line shut-off and push any one of the front or side pushbuttons to allow water to flow to the bubbler. On the EE model, actuate the solenoid by holding one hand approximately 3" from the infrared sensor. Run water until stream free of bubbles.

9. To Adjust Bubbler:a) All Pushbutton models are equipped with a Cartridge Regulator. The KEP8AC and KEPAC have a slot in the shelf below the

Pushbuttons. Insert a screwdriver in the slot to adjust regulator. Turn adjustment clockwise to increase stream height. To ac-cess the KEPV8AC adjustment, remove the Bezel and Button from the front of the cooler.

b) Electric Eye (EE) models have a Regulator built into the the Bubbler. If adjustment is needed, insert a 5/64" wrench approxi-mately 1 1/8" into the bubbler nozzle opening until it bottoms out and is seated in an adjust screw. Turn the adjust screw clockwise to reduce stream height or counter clockwise to increase the height. Note: less than one turn is required to go from a closed to a wide open flow. Do not over tighten the adjuster in the closed position as stripping the hex impression in the adjust screw may result. Turn the adjuster 1/16 of a turn at a time.

10. On electic eye equipped models, place and then hold hand approximately 3" from the sensor to actuate the solenoid valve. After approximately 30 seconds run time, the sensor will automatically shut off the solenoid valve. To reactivate, move hand away for an instant and then again place it in front of the sensor.

DRINKING FOUNTAIN INSTALLATIONFor All KEP( )AC-EBF Series Combination Drinking Fountains with Electronic Sports Bottle Filler

Page 2: DRINKING FOUNTAIN INSTALLATION...0615 2030008793 5 SECTION 1: GETTING STARTED WHAT’S INCLUDED? 1.op cap T 2. 38" of 1/4 OD plastic tubing with 19" of sponge tubing insulation 3.

0615 2030008793 2

11. To adjust the beam range of the sensor (EE models only):a) Shut off water and power supplies.b) Remove the four screws from the top front.c) Remove the eight screws from the bottom of the nose that holds the nose to the shelf.d) Remove the nose to gain access to the sensor adjusting screw located between the two lenses.e) The screw can be tuned a maximum of 3/4 turns. Turn screw counterclockwise to decrease range. The sensor has an adjust-

able range of 24" to 48". It is factory set at 27". There is a non-adjustable on-time delay of 0.75 seconds to prevent nuisance actuation of the solenoid valve should someone walk by. NOTE: Walls with a reflective finish i.e., ceramic tile, across from the sensor may cause false actuation no matter what the sensor adjustment is for distance. Therefore, do not install the unit in such an area or dull the surface of the wall so it will not reflect light.

C. MAINTENANCEThe only maintenance operation required is the removal of dirt and lint from the condenser where used. Inspection should be made at 3-month intervals. Disconnect the power supply cord, then clean the condenser with a small stiff non-wire or vacuum cleaner attach-ment brush when required. Observance if this procedure will insure adequate air circulation through the condenser so operation is efficient and economical.

D. OVERLOAD PROTECTIONThe compressor motor, where used, is equipped with an automatic reset protector which will disconnect the motor from the line in case of an overload.

E. LUBRICATIONThis unit is equipped with a hermetically sealed compressor and requires no additional lubrication. The fan motor, where used, on this unit seldom needs oiling, but if required, a few drops of SAE 10 oil should be used.

F. TO DISCONTINUE USE OF WATER COOLER1. Close water shut-off valve.

2. Provide container to catch water to be drained.

3. On the push button model, disconnect the water supply line at the shut off valve and remove the tank drain plug. Actuate and hold in the pushbutton to open the solenoid valve and completely drain the cooler. Disconnect the power supply cord.

4. On the EE model, disconnect the water supply line at the shut off valve and remove the tank drain plug. Actuate the solenoid, as explained in Step B-7 to completely drain the cooler. Disconnect the power supply cord.

5. Replace plug when draining is complete.

6. ALWAYS DRAIN ALL WATER WHEN FREEZING TEMPERATURES ARE ANTICIPATED AND BEFORE SHIPPING THE WATER COOLER.

*American With Disabilities Act

WARNING: The warranty and the Underwriters’ Laboratory Listing for this machine are automatically voided if this machine is altered, modified, or combined with any other machine or device. Alteration or modification of this machine may cause serious flood-ing and/or hazardous electrical shock or fire. EXCEPT AS SET FORTH HEREIN, THE MANUFACTURER MAKES NO OTHER WARRANTY, GUARANTEE OR AGREEMENT EXPRESSED, IMPLIED OR STATUTORY, INCLUDING ANY IMPLIED WARRANTY OR MERCHANT ABILITY OR FITNESS FOR A PARTICULAR PURPOSE.

DRINKING FOUNTAIN INSTALLATIONFor All KEP( )AC-EBF Series Combination Drinking Fountains with Electronic Sports Bottle Filler

Page 3: DRINKING FOUNTAIN INSTALLATION...0615 2030008793 5 SECTION 1: GETTING STARTED WHAT’S INCLUDED? 1.op cap T 2. 38" of 1/4 OD plastic tubing with 19" of sponge tubing insulation 3.

0615 2030008793 3

DRINKING FOUNTAIN ROUGH INFor All KEP( )AC-EBF Series Combination Drinking Fountains with Electronic Sports Bottle Filler

17 5/8 [447]

16 9/32 [413]

18 5/8 [472]

PUSH PADS

7/16 [11]1/2 [13]

16 1/32 [407]

7/16 [11]

1 1/4 IPS WASTEOPTIMUM LOCATIONSTUB OUT 1[25] INCH

33 3/8[848]

*29 5/16[745]

21 1/4[539]

18 1/16[459]

17[432]

16 1/2[419]

15 7/18 [392]

12 3/4 [324]

1/2 [10]

7 [8]

4 [99]

5 1/4[133]

ELECTRICALOUTLET OPTIMUMLOCATION

AIRFLOW

13 7/8[352]

48[1218]

51[1297]

*27[687]

1 1/4 O.D.TAILPIECE

3/8 O.D.WATER INLETWITH STRAINER

BOTTLE FILLERBUTTON

7/8 [22]

THIRD ANGLE PROJECTION ROUGH-INAND

DIMENSIONAL DRAWING

NOTES:

1. TRAP, STOP VALVE AND ELECTRICAL OUTLET NOT FURNISHED.

2. ALLOW 4 INCHES [102 MM] MIN. PER SIDE FOR VENTILATON.

* 3. RECOMMENDED ADULT BARRIER FREE HEIGHT INSTALLATION SHOWN. REDUCE HEIGHT BY 3 INCHES FOR INSTALLATIONS USED PRIMARILY BY CHILDREN AGES 12 AND YOUNGER. UNIT SHALL ALSO HAVE A MINIMUM CLEAR FLOOR SPACE 30[760] BY 48[1220]. ADJUST VERTICAL DIMENSIONS AS REQ’D TO COMPLY WITH PROVINCIAL AND LOCAL CODES.

4. ALL DIMENSIONS ARE IN INCHES. DIMENSIONS IN BRACKETS [ ] ARE IN MILLIMETERS.

Page 4: DRINKING FOUNTAIN INSTALLATION...0615 2030008793 5 SECTION 1: GETTING STARTED WHAT’S INCLUDED? 1.op cap T 2. 38" of 1/4 OD plastic tubing with 19" of sponge tubing insulation 3.

0615 2030008793 4

DRINKING FOUNTAIN INSTALLATIONFor All KEP( )AC-EBF Series Combination Drinking Fountains with Electronic Sports Bottle Filler

This HAND-FREE BOTTLE FILLER is an extension of the Franke drinking fountains product line that mounts directly above our Universal Drinking Fountain.

The wall requires a standard 2-outlet electrical receptacle to accommodate the electrical cords from both the fountain and the bottle filler. Otherwise, a grounded plug-in outlet adapter will be required.

If installed onto a refrigerated drinking fountain, chilled water can be dispensed through the Bottle Filler. Otherwise, room temperature water will be dispensed.

The Bottle Filler is shipped partially assembled.

If you ordered the Bottle Filler as a combination with a Drink-ing Fountain, the drinking fountain is plumbed and ready to attach to the bottle filler.

WHEN COMPLETED, THE FINISHED ASSEMBLY WILL LOOK LIKE THIS:

Shown here with the Sandstone cabinet finish

Page 5: DRINKING FOUNTAIN INSTALLATION...0615 2030008793 5 SECTION 1: GETTING STARTED WHAT’S INCLUDED? 1.op cap T 2. 38" of 1/4 OD plastic tubing with 19" of sponge tubing insulation 3.

0615 2030008793 5

SECTION 1: GETTING STARTED

WHAT’S INCLUDED?1. Top cap2. 38" of 1/4 OD plastic tubing with 19" of sponge tubing insulation3. Gasket4. Quick connect tee fitting (only required on split level models)5. Installation instructions6. Drip tray7. Anti splash grate8. Anti Splash grate screws (2)9. Snap bushing10. Wrap-around cabinet facing11. Hands-free sports bottle filler

1.

2.

3.

4.

5.

6.

7.

8.

9.

10.

11.

TOOLS REQUIRED:- 3/8" pilot drill and either a step drill bit up to 7/8" diameter that will drill through stainless steel top or 7/8" diameter punch die (retrofit version only)- Electric drill- Small tubing cutter for copper tube- T15 Torx driver with pin in head vandal tip- T20 Torx driver with pin in head vandal tip- 1/4" nut driver- #2 Phillips screw driver

NOT PRE-DRILLED/BOTTLE FILLER KIT: If the unit is not pre-drilled or you purchased a BOTTLE FILLER retrofit KIT, go to PAGE 6A.

PRE-DRILLED/PLUMBED: If your unit was purchased pre-drilled and plumbed at the factory as a COMBINATION, go to PAGE 12C.

Page 6: DRINKING FOUNTAIN INSTALLATION...0615 2030008793 5 SECTION 1: GETTING STARTED WHAT’S INCLUDED? 1.op cap T 2. 38" of 1/4 OD plastic tubing with 19" of sponge tubing insulation 3.

0615 2030008793 6

SECTION 2: PRESSURIZING THE COOLING TANK

PRESSURIZED COOLING TANK

NON-PRESSURIZEDCOOLING TANK

Cool

ing

tank

Water valve/regulator

SupplyWater

Water valve/regulator

SupplyWater

Cool

ing

tank

The water should already be turned OFF and the power DISCONNECTED.

A. NON-PRESSURIZED COOLING TANKIf the cooling tank is non-pressurized, follow these instructions. Otherwise, proceed to SECTION 3.

Page 7: DRINKING FOUNTAIN INSTALLATION...0615 2030008793 5 SECTION 1: GETTING STARTED WHAT’S INCLUDED? 1.op cap T 2. 38" of 1/4 OD plastic tubing with 19" of sponge tubing insulation 3.

0615 2030008793 7

STEP 2Unplug un-insulated water line from water valve inlet (JG elbow located left side of water valve facing the front of the cooler). Set tubing aside (being careful to not con-taminate the water contact in of the tube).

STEP 3Unplug tubing from JG elbow leading to cooling tank inlet.

SECTION 2: PRESSURIZING THE COOLING TANK

A. NON-PRESSURIZED COOLING TANK (continuation)

STEP 1Unit as it appears with top removed.

Page 8: DRINKING FOUNTAIN INSTALLATION...0615 2030008793 5 SECTION 1: GETTING STARTED WHAT’S INCLUDED? 1.op cap T 2. 38" of 1/4 OD plastic tubing with 19" of sponge tubing insulation 3.

0615 2030008793 8

SECTION 2: PRESSURIZING THE COOLING TANK

A. NON-PRESSURIZED COOLING TANK (continuation)

STEP 4Plug un-insulated tubing that was removed in Step 1 into JG elbow leading to the cooling tank from Step 3.

STEP 5Unplug tubing that is onnected to the water valve outlet (JG elbow located on the right side of valve facing the cooler.

STEP 6Connect tubing from Step 5 to JG elbow on the left side of the valve.

Page 9: DRINKING FOUNTAIN INSTALLATION...0615 2030008793 5 SECTION 1: GETTING STARTED WHAT’S INCLUDED? 1.op cap T 2. 38" of 1/4 OD plastic tubing with 19" of sponge tubing insulation 3.

0615 2030008793 9

SECTION 2: PRESSURIZING THE COOLING TANK

A. NON-PRESSURIZED COOLING TANK (continuation)

STEP 7Unplug JG tubing from the cooling tank outlet. Do not set it down.

STEP 8Using tubing removed in Step 7, plug into JG elbow on the right side of the valve. (Be sure to re-route the tubing under existing tubing installed in Step 5 as shown.

STEP 9Using tubing that is connected to the JG elbow left side of valve (done in Step 5, plug the other end to the JG fitting at the top of the cooling tank.

Page 10: DRINKING FOUNTAIN INSTALLATION...0615 2030008793 5 SECTION 1: GETTING STARTED WHAT’S INCLUDED? 1.op cap T 2. 38" of 1/4 OD plastic tubing with 19" of sponge tubing insulation 3.

0615 2030008793 1050112 036865-003

SECTION 3: INSTALLATIONWATER COOLER INSTALLATION INSTRUCTIONS, MODELS: KEPWSBF

A. DRILLING HOLE IN THE TOP FOR WATER LINE CONNECTION1. Disconnect power by UNPLUGGING unit. It might be necessary to remove the front panel to get access to the power.

2. Turn OFF water supply to the unit. It might be necessary to remove the front panel to access the water stop valve.

3. Place hole template onto cooler top so it is aligned with the left side of unit and wall. (TEMPLATE FOUND ON PAGE 17)

4. Mark hole location.

5. Remove top from unit. (Figure 1)

6. Using a 3/8 drill bit, drill a hole through top.

7. Install snap bushing into hole to protect tubing from being cut. (Figure 2)

B. CONNECTING THE WATER LINE If the cooling tank is non-pressurized, then go to the "Pressurizing the cooling tank" addendum section. Otherwise, proceed to STEP 1 next page. Non-pressurized units are single units made since December of 2009. Refer to the schematic below to identify the system that you have.

Mark hole locationTemplate

Remove top from cooler by removing six #15 torx head

screws on sides of top.

Figure 1 Figure 2

Drill Install Bushing

PRESSURIZED COOLING TANK

NON-PRESSURIZEDCOOLING TANK

Cool

ing

tank

Water valve/regulator

SupplyWater

Water valve/regulator

SupplyWater

Cool

ing

tank

B. RETROFIT or FOUNTAIN/FRAME - PRESSURIZED (for units not pre-plumbed and pre-drilled)

a) Disconnect power by UNPLUGGING unit. It might be necessary to remove the front panel to get access to the power.b) Turn OFF water supply to the unit. It might be necessary to remove the front panel to access the water stop valve.c) Place hole template onto cooler top so it is aligned with the left side of unit and wall. SEE NEXT PAGE FOR TEMPLATE.d) Mark hole location.e) Remove top from unit. (Figure 1)

f) Using a step drill bit OR 7/8" punch die, make a 7/8" hole through top. You may want to drill a pilot hole to get these started.g) Install snap bushing into hole to protect tubing from being cut. (Figure 2)

SECTION 3: CONNECTING THE WATER LINEDRINKING FOUNTAIN

Page 11: DRINKING FOUNTAIN INSTALLATION...0615 2030008793 5 SECTION 1: GETTING STARTED WHAT’S INCLUDED? 1.op cap T 2. 38" of 1/4 OD plastic tubing with 19" of sponge tubing insulation 3.

0615 2030008793 11

USE THIS TEMPLATE TO MARK THE HOLELOCATION ON COOLER TOP

2 1/8 po[5.4cm]FROMBACK

Mark this center point on the top.Remove the top from the cooler.Then drill a 7/8" [2.2cm] hole throughthe top at the marked centre point.

ALIGN THIS EDGE WITH LEFT EDGE OF COOLER TOP

3 1/4 po [8.3cm]

FROM SIDE

PLA CE TH

IS EDG

E AG

AIN

ST WA

LL

Page 12: DRINKING FOUNTAIN INSTALLATION...0615 2030008793 5 SECTION 1: GETTING STARTED WHAT’S INCLUDED? 1.op cap T 2. 38" of 1/4 OD plastic tubing with 19" of sponge tubing insulation 3.

0615 2030008793 12

SECTION 3: CONNECTING THE WATER LINEDRINKING FOUNTAIN

¼" OD tube to connect to Bottle Filler

a) First, remove plug from fitting on tank drain. b) Next, insert end of tube into fitting.

Figure10

c) Feed tubing up through the top and attach the top to the cooler. (Figure 1) 

C. CONNECT THE BOTTLE FILLER TUBEThis tube supplies cold water from the cooling tank to the Bottle Filler.

Figure 1

Page 13: DRINKING FOUNTAIN INSTALLATION...0615 2030008793 5 SECTION 1: GETTING STARTED WHAT’S INCLUDED? 1.op cap T 2. 38" of 1/4 OD plastic tubing with 19" of sponge tubing insulation 3.

0615 2030008793 13

SECTION 4: MOUNTING THE FRAME TO THE WALL

STEP 1:Place rubber gasket on top of the cooler so it is centered left/right and against the wall. (Figure 11)

STEP 2:Set the wall frame onto the gasket. Center it left/right and push it against the wall and mark hole locations for wall fasteners. The gasket will set the frame at the proper height. (Figure 12)STEP 3:Secure frame to the wall with fasteners (not provided). Pull plastic tubing up through the hole in the frame. Use mounting slots that will provide the proper securing location. Make sure to pull the plastic tubing up through the hole in the frame.

Figure 11 Figure 12Make sure to pullthe plastic tubingup through thehole in the frame.

Use mounting slots that will provide the proper securing location.

Bottle filler cabinet

Groove in the gasket

Figure 14

STEP 4:Slide sponge tubing insulation over water line. Connect the tubing to the INLET elbow on the back of the Hands-free Bottle Filler assembly and flow switch connector into the port on the circuit board. (Figure 13)

STEP 5:Set the bottle filler cabinet into place. MAKE SURE the cabi-net fits into the groove in the rubber gasket on both sides and front of the cabinet wrapper. (Figure 14)

Connect tube to inlet of the valve

Plastic tubing

Rear view of Bottle Filler

Sponge tubing insulation

Insert connector on end of flow switch wire into port on circuit board

Figure 13

Page 14: DRINKING FOUNTAIN INSTALLATION...0615 2030008793 5 SECTION 1: GETTING STARTED WHAT’S INCLUDED? 1.op cap T 2. 38" of 1/4 OD plastic tubing with 19" of sponge tubing insulation 3.

0615 2030008793 14

STEP 6:Attach Bottle Filler assembly to the frame using the four (4) vandal resistant torx screws. Leave the top cap off until after the program is set for this installation (Figure 15)

Figure 15

Torx screws

Figure 16 Figure 17

Anti-splash grate screws (provided)

Anti-splash grate

Drip tray

Press

INSTALLATION COMPLETE

SECTION 4: MOUNTING THE FRAME TO THE WALL (cont'd)

STEP 7:Install the drip tray and anti-splash grate into the al-cove area and secure with the two (2) stainless steel Phillips head screws. (Figure 16)

STEP 8:Connect male tab terminals from bottle filler power supply to female terminals on power cord. Make sure male tab is seated inside metal contacts of female terminal.

STEP 9:Plug in bottle filler cord. The program should be set up specific for that installation. See the program guide on the next page.

STEP 10:Turn ON water supply and check for leaks. Place a bottle in the alcove to release any trapped air from the system. Plug in the power cord and replace the front panel. (Figure 17)

STEP 11:If everything works correctly, place the top cap back on the bottle filler and use the remaining two (2) torx screws to fasten it in place. Otherwise, calibrate the sensor per the instructions on the next page.

Page 15: DRINKING FOUNTAIN INSTALLATION...0615 2030008793 5 SECTION 1: GETTING STARTED WHAT’S INCLUDED? 1.op cap T 2. 38" of 1/4 OD plastic tubing with 19" of sponge tubing insulation 3.

0615 2030008793 15

SECTION 5: PROGRAM GUIDE FOR ELECTRONIC BOTTLE FILLER

Factory default settings are for:• an UNFILTERED unit• a 20-second maximum run time

1. Top cap is set aside until program is complete. Remove top cap by unscrewing two (2) T15 torx screws, if needed.

2. Reach hand down between frame and front of cabinet to gently press button sticking up from top of circuit board (Note: Circuit board runs on low voltage and will not shock you). A remote button is available. Remove wire tie, bundling it inside bottle filler and feed it through hole in cooler top. You can then adjust program using button through access panel of cooler.

3. To enter program mode, press and hold button for about 3 seconds. When you hear a beep, let go of button. You are now in Program Mode. Pressing button for an instant will advance to next screen. It will revert back to Operating Mode if no button is pressed for 10 seconds.

4. When you enter Program Mode, display screen will read “UNFILTERED UNIT.” To access settings for “FILTERED UNIT”, press and hold button for about 3 seconds. Press button for an instant to advance to next menu item.

5. If you wish to reset filter life counter or bottle counter, press and hold button for 3 seconds in screen asking corresponding question.

6. Default capacity for filter life counter is 1250 gallons (to match VERSAFILTER® filter). Press and hold button 3 seconds in “FILTER CAPACITY OF…” screen to change setting to 3000 gallons (GALAXI® green filter media - may not be available at time of printing).

7. “Bottle Filler Set_time” screen is to adjust maximum run time once sensor is activated. Water flow will stop once container is removed from alcove, but this feature ensures very little water is wasted if some-one tampers with dispenser.

8. Unit is calibrated at factory, but it is recommended that sensor be recalibrated at each install. Also, if you are having problems with sensing of a bottle, try recalibrating it before calling for service. Press and hold button for 3 seconds to calibrate sensor in “INFRARED SENSITIVITY” screen.

9. Put top cap back on and fasten in place with two (2) torx screws.

Status / Statut

OkService soon

Service Recommended

D’accordService bientôtService recommandé

BOTTLES SAVEDBOUTEILLES SAUVÉES

Page 16: DRINKING FOUNTAIN INSTALLATION...0615 2030008793 5 SECTION 1: GETTING STARTED WHAT’S INCLUDED? 1.op cap T 2. 38" of 1/4 OD plastic tubing with 19" of sponge tubing insulation 3.

0615 2030008793 16

1

2

326

5

6

7

89

10

11

12 13 14

15

16

17

1819

20

21

22

22

22

23

24

25

25

22

4

27

28

29

30

31

32

33

EXPLODED PARTS BREAKDOWNELECTRONIC SPORTS BOTTLE FILLER

Page 17: DRINKING FOUNTAIN INSTALLATION...0615 2030008793 5 SECTION 1: GETTING STARTED WHAT’S INCLUDED? 1.op cap T 2. 38" of 1/4 OD plastic tubing with 19" of sponge tubing insulation 3.

0615 2030008793 17

EXPLODED PARTS BREAKDOWNELECTRONIC SPORTS BOTTLE FILLER

Haws is a registered trademark of HAWS Corporation.Elkay and Halsey Taylor are registered trademarks owned or licensed byElkay Sales Inc. and/or its parent Elkay Manufacturing Company.

1. 036190-002 Alcove2. 036691-001 Wrapper3. 036686-001 Cap4. 036049-002 Screw, flat head tapping5. 036688-001 Tray, drip6. 036695-001 Tray, grille drip7. 036697-001 Bottom cap for drip tray8. 036194-002 Button9. 034649-001 Spring10. 036689-001 Gasket11. 036191-002 Drain, short12. 035990-001 Holder, cartridge stem connector13. 029967-002 Cartridge14. A020957 Nut, retaining plastic15. 036690-001 Bracket, valve16. 030176-002 Plug, hole17. 028706-036 Washer/spacer/gasket-non metallic18. 026670-007 Screw, hex heavy duty machine19. 028481-101 Fitting, PP union elbow white20. 036209-001 Fill tube assembly21. 026642-003 Bracket, fill tube support22. 026642-003 Screw, hex heavy duty tapping23. 031206-005 Insert, nameplate “Aquapointe”24. 030152-046 Tube, PE cut length white25. 031875-003 Screw, button heavy duty tapping26. 036687-001 Frame27. 027189-007 Bushing, snap28. 029199-103 Fitting, PP untion tee white29. 030152-031 Tube, PE cut length white30. 017681-008 Insulation, sponge tubing31. 036701-001 Drip tray assembly, service32. 036702-001 Button assembly, service33. 036231-001-SP Valve assembly, dispense-service

Accessory Kits036704-001 Vandal resistant screw kit - Includes torx bits and replacement screws for items 4, and 25SRH-KEPWSBF Gasket, Sunroc/Haws #036689-101 - Replaces item 10EKG-KEPWSBF Gasket, Elkay/Halsey Taylor #036689-201 - Replaces item 10

Page 18: DRINKING FOUNTAIN INSTALLATION...0615 2030008793 5 SECTION 1: GETTING STARTED WHAT’S INCLUDED? 1.op cap T 2. 38" of 1/4 OD plastic tubing with 19" of sponge tubing insulation 3.

0615 2030008793 18

VoltageSizeShipping Weight (Approx)Cold Water CapacityCompressorCompressor (Full Load)RefrigerantRefrigerant ChargeRoom Temperature Supply Water Temperature Drinking Water Temperature

Specifications subject to change without notice.

115 VAC±10%/1 PH/60 Hertz17 5/8" W, 18 5/8" D, 18 29/32" H59 lbs.8 GPH1/4 hp4.4 amps134a3.95 OZ90◦F80◦F50◦F

SPECIFICATIONSCHILLED DRINKING FOUNTAIN

Page 19: DRINKING FOUNTAIN INSTALLATION...0615 2030008793 5 SECTION 1: GETTING STARTED WHAT’S INCLUDED? 1.op cap T 2. 38" of 1/4 OD plastic tubing with 19" of sponge tubing insulation 3.

0615 2030008793 19

To adjust stream height, insert a 1/8" flat blade screwdriver into the slotted hole as shown. The screwdriver will engage the stream height adjuster in the cartridge plunger. Turn clockwise to increase stream height or counter clockwise to reduce stream height.

Page 20: DRINKING FOUNTAIN INSTALLATION...0615 2030008793 5 SECTION 1: GETTING STARTED WHAT’S INCLUDED? 1.op cap T 2. 38" of 1/4 OD plastic tubing with 19" of sponge tubing insulation 3.

0615 2030008793 20

Item Single Split Level Single# Description...............................................................Chilled ......................Chilled ......................Non-chilled1. Top ........................................................................... 031714-101 ..............031714-101 .............. 031714-101 2. Bubbler .................................................................... 035607-108 ..............103607-108 .............. 035607-1083. Washer, under top .................................................... 028706-030 ..............028706-030 .............. 028706-0304. Locknut .................................................................... 026824-019 ..............026824-019 .............. 026824--1095. Bubbler nut W/ JG (John Guest)................................ 036026-001 ..............036026-001 .............. 036026-0016. Condenser ............................................................... 031766-201 ..............031766-201 ..............Not applicable7. Side panel, Left – Sandstone ................................... 035080-009 ..............035080-309 .............. 035080-009

Side panel, Left – Greystone ................................... 035080-001 ..............035080-301 .............. 035080-001 Side panel, Left – Stainless Steel ............................. 035080-010 ..............035080-310 .............. 035080-010

8. Blade, fan ................................................................. 024033 .....................024033 .....................Not applicable9. Motor, fan ................................................................ 027354-036 ..............027354-036 ..............Not applicable10. Bracket, fan motor.................................................... 036478-001 ..............036478-001 ..............Not applicable11. Drain screw .............................................................. 036049-002 ..............036049-002 .............. 036049-00212. Waste gasket ............................................................ 031756-002 ..............031756-002 .............. 031756-00213. Hanger bracket ........................................................ 031363-002 ..............031363-002 .............. 031363-00214. Side panel, Right - Sandstone ................................... 035081-009 ..............035081-009 .............. 035081-309 Side panel, Right - Greystone ................................... 035081-001 ..............035081-001 .............. 035081-301 Side panel, Right - Stainless Steel ............................ 035081-010 ..............035081-010 .............. 035081-31015. Patch plate - Sandstone ........................................... Not applicable ...........036142-009 .............. 036142-009 Patch plate - Greystone ............................................ Not applicable ...........031642-001 .............. 031642-001 Patch plate - Stainless Steel ..................................... Not applicable ...........031642-010 .............. 031642-01016. Service cord ............................................................. 026540-045 ..............026540-045 ..............Not applicable17. Frame ...................................................................... 035089-001 ..............035089-001 .............. 035089-00118. Waste assembly ....................................................... 036011-001 ..............036011-002 .............. 036009-00219. Insulation, right cooling tank .................................... 035088-001 ..............035088-001 ..............Not applicable20. Insulation, left cooling tank ...................................... 035088-002 ..............035088-002 ..............Not applicable21. Cooling tank, insulated ............................................. 035469-055-SP .........035469-055-SP .........Not applicable22. Cold control ............................................................. 027040-039 ..............027040-039 ..............Not applicable23. Relay ........................................................................ 036056-003 ..............036056-003 ..............Not applicable24. Overload .................................................................. 036055-003 ..............036055-003 ..............Not applicable25. Start capacitor — 60 MFD ........................................ 027956-008 ..............027956-008 ..............Not applicable26. Run capacitor —25 MFD ........................................... 027956-009 ..............027956-009 ..............Not applicable27. Compressor assembly .............................................. 036115-001 ..............036115-001 ..............Not applicable28. Front panel, Right - Sandstone ................................. 035079-009 ..............035079-009 .............. 035079-009 Front panel, Right - Greystone .................................. 035079-001 ..............035079--001 ............. 035079--001 Front panel, Right - Stainless Steel ........................... 035079-010 ..............035079-010 .............. 035079-01029. Front nose piece - Sandstone ................................... 035077-009 ..............035077-009 .............. 035077-009 Front nose piece - Greystone ................................... 035077-001 ..............035077-001 .............. 035077-001 Front nose piece - Stainless Steel ............................ 035077-010 ..............035077-010 .............. 035077-01030. Activation assembly ................................................. 035412-004 ..............035412-004 .............. 035412-00431. Water line, tank to valve ........................................... 035504-011-SP .........035504-011-SP ......... 035503-001 Water line, inlet to valve or tank ................................ 035504-010-SP .........035504-010-SP .........Not applicable32. Union elbow fitting JG (John Guest) ........................... 02481-101 ................028481-101 .............. 028481-10133. Cartridge holder ....................................................... 035990-00 ................035990-001 .............. 035990-00134. Cartridge .................................................................. 029967-002 ..............029967-002 .............. 029967-00235. Retaining nut, cartridge ............................................ A020957 ...................A020957 ................... A02095736. Water line, tank or valve to bubbler ........................... 035504-013-SP .........035504-013-SP ......... 035504-013-SP37. Shelf ........................................................................ 035078-002 ..............035078-002 .............. 035078-00238. Dryer ........................................................................ 034343-003 ..............034343-003 ..............Not applicable39. Activation shelf......................................................... 035092M101 ............035092M101 ............ 035092M10140. Waste tee ................................................................. Not applicable ...........A020968 ................... A02096841. Waste arm assembly ................................................ Not applicable ...........026980-004 .............. 0269980-00442. Waste elbow ............................................................. Not applicable ...........A020967 ................... A02096743. Waste extension tube ............................................... Not applicable ...........036010-016 .............. 036010-016 Parts Not Shown: Strainer, in-line ......................................................... 033264-003 ..............033264-003 .............. 033264-003

PARTS BREAKDOWN LISTDRINKING FOUNTAIN

Page 21: DRINKING FOUNTAIN INSTALLATION...0615 2030008793 5 SECTION 1: GETTING STARTED WHAT’S INCLUDED? 1.op cap T 2. 38" of 1/4 OD plastic tubing with 19" of sponge tubing insulation 3.

0615 2030008793

Franke Kindred Canada LimitedFranke Commercial Systems1000 Franke Kindred RoadMidland, ON L4R 4K9

Tel 1.855.446.5663Fax 1-866-227-3050www.franke-commercial.com

WIRING DIAGRAMDRINKING FOUNTAIN WIRING DIAGRAM

Single KEP(__) series,Split Level KEP (__) seriesSingle KEP(_) Series

Split Level KEP(_)ACSL Series


Recommended