10
Pulp & Paper Technology Presentation DRT-5200 FCW 2010/2 -1 Drainage Measurement BTG transmitter DRT-5200 Refining control Refining control with with Drainage Measurement Drainage Measurement
Transcript
  • Refining control withDrainage Measurement

    Drainage MeasurementBTG transmitter DRT-5200

  • On-line Freeness measurementBenefits

    Simple and accurate measuring methodControl over energy consumption and fiber utilizationAllows automatic freeness control

  • Sampling,dilution andmixing phase

    MeasuringphaseCleaning phase

    Formationphase

    TempTimeWaterAIRWaterMeasuring principle

  • When consistency is above 1 %, it flocculates and forms water channels.Flocculation disturbs the drainage measurement when consistency is above 1%.Measuring principleDilution of the sample before measurement

  • Refining benefitsNo refining After refining

  • Refining control benefitsCSF600.00% LOAD100%50.00100.0001234567Day1-DRT-52002-Lab3-Refiner load

  • Refining control benefitsMD CALIPER SPREAD0.1090.064FEB1 - SEP 18 BASELINESEP 19 - OCT 31 FREENESS CONTROL0.150.10.050

  • Refining control strategyDrainageRate ControlSpecific RefiningEnergy ControlSPSPFTCRC

  • Technical dataFreeness range 700-15 CSF/15-98SRMax media temp. 95C/203FAutomatic temp compensation for water temp variationConsistency range 1-6 %Drainage Rate TransmitterDRT-5200

  • Drainage Rate TransmitterBenefitsLow cost and simple installationQuick on-line measurement with signal update in < 2 minLow maintenance requirement DRT-5200