+ All Categories
Home > Documents > ds 03026-EN-0319-CF2 85 - Re SpA

ds 03026-EN-0319-CF2 85 - Re SpA

Date post: 30-Nov-2021
Category:
Upload: others
View: 3 times
Download: 0 times
Share this document with a friend
2
Re S.p.A. via Firenze 3 20060 Bussero (MI) Italy T +39 02 9524301 F +39 02 95038986 E [email protected] Assistenza tecnica Technical support T +39 02 952430.300 E [email protected] Assistenza commerciale Sales support T +39 02 952430.200 E [email protected] CF2.85 FLANGE LOAD CELL A reliable web tension control may reduce web tears in order to increase productivity. CF ange load cells, used in a precise tension control system, are designed to carry out these delicate tasks. They are installed at the end of a measuring roller to precisely detect the resultant of the forces generated by pulling of the material depending on the wrapping angle. CF load cells have been designed with a compact design, to easily t them in narrow spaces, to be installed very easily and to reach a very high reliability. CF2.85 is a special ange load cells specically designed for applications that require high overloads as it guarantees an overload protection up to 10 times the nominal load. Moreover the sensor can be oriented of ± 30° without changing the xing holes in order to precisely align it to the resultant force. Operating principle: CF load cells use the strain gauge operating principle to guarantee a perfect detection of the web tension. Strain gauges resistors are mounted on a inner metal foil of a load cell and connected to each other in a wheatstone bridge able to convert a mechanical movement into an electrical signal, that must be amplied by suitable ampliers. Overload protection up to 10 times the nominal load Sensor rotation ± 30° without change the load cell xing Compact design Easy and quick installation High reliability Strain gauge technology IP54 protection class Measuring range from 250N to 2000N Datasheet 03026/EN - 03/19 v2
Transcript

Re S.p.A. via Firenze 320060 Bussero (MI) Italy

T +39 02 9524301 F +39 02 95038986 E [email protected]

Assistenza tecnicaTechnical supportT +39 02 952430.300E [email protected]

Assistenza commercialeSales supportT +39 02 952430.200E [email protected]

CF2.85FLANGE LOAD CELL

A reliable web tension control may reduce web tears in order to increase productivity. CF ange load cells, used in a precise tension control system, are designed to carry out these delicate tasks.They are installed at the end of a measuring roller to precisely detect the resultant of the forces generated by pulling of the material depending on the wrapping angle.

CF load cells have been designed with a compact design, to easily t them in narrow spaces, to be installed very easily and to reach a very high reliability.

CF2.85 is a special ange load cells specically designed for applications that require high overloads as it guarantees an overload protection up to 10 times the nominal load. Moreover the sensor can be oriented of ± 30° without changing the xing holes in order to precisely align it to the resultant force.

Operating principle: CF load cells use the strain gauge operating principle to guarantee a perfect detection of the web tension. Strain gauges resistors are mounted on a inner metal foil of a load cell and connected to each other in a wheatstone bridge able to convert a mechanical movement into an electrical signal, that must be amplied by suitable ampliers.

Overload protection up to 10 times the nominal load

Sensor rotation ± 30° without change the load cell xing

Compact design

Easy and quick installation

High reliability

Strain gauge technology

IP54 protection class

Measuring range from 250N to 2000N

Datasheet 03026/EN - 03/19 v2

Re S.p.A. via Firenze 320060 Bussero (MI) Italy

T +39 02 9524301 F +39 02 95038986 E [email protected]

Assistenza tecnicaTechnical supportT +39 02 952430.300E [email protected]

Assistenza commercialeSales supportT +39 02 952430.200E [email protected]

TECHNICAL DRAWING

Red point resultantdirection

90°

ø84

ø70

95

ø6,5

ø10,5 13,5

6 poles jack 20

2519,3

3,3

26,7

72,5

1,5

Bearing 2203 2RS

ø50

g6

ø40

ø55

The sensor can be rotateof ± 30° to align it to the resultant

Precision class 0.5%

Sensitivity Normal from 1,5mV/V to 2,0mV/V Supply max 15V (max at full-scale value: 20mV)

Total error-repeatability-histeresy-linearity <0,05% full-scale value

Measuring principle strain gauge full bridge

Strain gauge bridge resistance 350Ω Ohm

Max overload 10 times the nominal load

Temperature compensation +10°C ÷ +50°C

Working temperature +10°C ÷ +50°C

IP protection class IP54

*Data are subject to technical change without notice

TECHNICAL DATA

CALCULATION

α

P=0T

T

F

α

PT

T

α

PT

TF

ß

HORIZONTAL RESULTANT DOWNWARD RESULTANT UPWARD RESULTANT

F = T sin α/2 F = T sin α/2 + P/2 cosß F = T sin α/2 - P/2 cosß

Load N

5001000

CF2.85.25.40 250

* for other model contact our technical dpt.

Selection model table

CF2.85.xx.xxLoad N

Ball bearing sizeLoad cell model

CF2.85.50.40CF2.85.100.40

Code

2000CF2.85.200.40

bearing size

40x1740x17

40x17

40x17


Recommended