www.intertec.info INTERTEC Instrumentation Ltd. · 225 Henry Drive · Sarnia, Ontario N7T 7H5 · Canada · +1 888 875 8756 · [email protected] DS2720 Passive Sample Cooler DD410-0c DS2720 Passive Sample Cooler Page 1/ 1 1 Application Samples of fluids and gases in industrial plants are often very hot. That can be a danger for personal and plant. Inflammable substances may not get in contact with air above their auto ignition temperature. INTERTEC’s passive sample cooler makes sure, that the sample temperature is max. 140° F/ 60° C. 2 Special Advantages Off-the-shelf product, function proved in industrial and refinery operation. Modification according to works standard (materials, valves, connections) easily possible. Process Lay-Out according to the individual application (temperature etc.). Autarkic system: no supply of media like cooling water or process air necessary. Explosion proof for Zone 1 or Class I Div.1 3 Description The passive sample cooler works according to principle of the passive cooler: If the ball valve is opened, the sample flows through a stainless steel coil inside a stainless steel water tank. The thermal energy is transferred to the water. Due to the fact, that the thermal capacity of water is approx. 2 times as high as the thermal capacity of i.e. hotoil, the temperature of the water increases slowly. 4 Other Manual Sample Systems Ball Valve Needle Valve
Transcript
Page 1: DS2720 Passive Sample CoolerDS2720 Passive Sample Cooler DD410-0c DS2720 Passive Sample Cooler Page 1/ 1 1 Application Samples of fluids and gases in industrial plants are often very

www.intertec.info

INTERTEC Instrumentation Ltd. · 225 Henry Drive · Sarnia, Ontario N7T 7H5 · Canada · +1 888 875 8756 · [email protected]

DS2720 Passive Sample Cooler

DD410-0c DS2720 Passive Sample Cooler Page 1/ 1

1 Application

Samples of fluids and gases in industrial plants are often very hot. That can be a danger for personal and plant. Inflammable substances may not get in contact with air above their auto ignition temperature.

INTERTEC’s passive sample cooler makes sure, that the sample temperature is max. 140° F/ 60° C.

2 Special Advantages

Off-the-shelf product, function proved in industrial and refinery operation.

Modification according to works standard (materials, valves, connections) easily possible.

Process Lay-Out according to the individual application (temperature etc.).

Autarkic system: no supply of media like cooling water or process air necessary.

Explosion proof for Zone 1 or Class I Div.1

3 Description

The passive sample cooler works according to principle of the passive cooler:

If the ball valve is opened, the sample flows through a stainless steel coil inside a stainless steel water tank. The thermal energy is transferred to the water.

Due to the fact, that the thermal capacity of water is approx. 2 times as high as the thermal capacity of i.e. hotoil, the temperature of the water increases slowly.

4 Other Manual Sample Systems

Ball Valve Needle Valve

Recommended