Page 1: DSA E‑Series (E2800 60‑bay) · – Install the unit only in a dry, weather-protected location. – Do not use this unit near water, for example near a bathtub, washbowl, sink,

DSA E‑Series (E2800 60‑bay)DSA‑N6C8X4‑60AT | DSA‑N6C8X8‑60AT | DSA‑N6C8XC‑60AT |DSX‑N6D8X4‑60AT | DSX‑N6D8X8‑60AT | DSX‑N6D8XC‑60AT |DSX‑NRCK40‑INT8

en Installation manual

Page 2: DSA E‑Series (E2800 60‑bay) · – Install the unit only in a dry, weather-protected location. – Do not use this unit near water, for example near a bathtub, washbowl, sink,
Page 3: DSA E‑Series (E2800 60‑bay) · – Install the unit only in a dry, weather-protected location. – Do not use this unit near water, for example near a bathtub, washbowl, sink,

DSA E-Series (E2800 60-bay) Table of contents | en 3

Bosch Security Systems B.V. Installation manual 2020.11 | V2 | DOC

Table of contents1 Safety 51.1 Safety message explanation 51.2 Safety precautions 51.3 Important safety instructions 51.4 Warning notices 71.5 Caution notices 81.6 Notices 82 Introducton 102.1 Hardware registration 102.2 Additional equipment 102.3 Additional documentation 103 System overview 113.1 Device views 113.2 LED description 123.2.1 LEDs on the operator display panel 123.2.2 LEDs on the controller unit 133.2.3 LEDs on the I/O modules 153.2.4 LEDs on the drives 163.2.5 LEDs on the drive drawer 173.2.6 LEDs on the power canister 183.2.7 LEDs on the fan canister 184 Installation 204.1 Installing a 60-bay unit 204.2 Installing a 60-bay unit with SuperRail 214.2.1 Installing SuperRail to square-hole four-post rack 214.2.2 Installing SuperRail to round-hole four-post rack 234.3 Installing the drives 264.4 Installing the front bezel and end caps 264.5 Setting the unit ID using the ODP button 275 Connection 285.1 Connecting the expansion units 285.2 Connecting the controller unit to the network 285.3 Connecting the controller unit to the management hosts 295.4 Connecting the units to the power supply 305.5 Supported connections 316 Turning on/off AC power 336.1 Turning on AC power 336.2 Turning off AC power 337 Configuring the storage system 348 Maintenance 368.1 Replacing a drive in a 60-bay unit 368.1.1 Preparing to replace a drive 378.1.2 Removing a drive 388.1.3 Installing a drive 398.1.4 After replacing a drive 408.2 Replacing a power canister 418.2.1 Preparing to remove a power canister 428.2.2 Removing a power canister 43

Page 4: DSA E‑Series (E2800 60‑bay) · – Install the unit only in a dry, weather-protected location. – Do not use this unit near water, for example near a bathtub, washbowl, sink,

4 en | Table of contents DSA E-Series (E2800 60-bay)

2020.11 | V2 | DOC Installation manual Bosch Security Systems B.V.

8.2.3 Installing a power canister 438.2.4 After replacing a power canister 438.3 Replacing a fan canister 448.3.1 Preparing to remove a fan canister 458.3.2 Removing and replacing a fan canister 468.3.3 After replacing a fan canister 468.4 Seven-segment display codes 478.4.1 Seven-segment display sequence codes 478.4.2 Seven-segment display codes when controller turns on 488.4.3 Seven-segment display use cases 488.4.4 Seven-segment display lock-down codes 508.5 Collecting support data for the storage system 519 Support services and Bosch Academy 53

Page 5: DSA E‑Series (E2800 60‑bay) · – Install the unit only in a dry, weather-protected location. – Do not use this unit near water, for example near a bathtub, washbowl, sink,

DSA E-Series (E2800 60-bay) Safety | en 5

Bosch Security Systems B.V. Installation manual 2020.11 | V2 | DOC

1 Safety1.1 Safety message explanation

iNotice!Indicates a situation which, if not avoided, could result in damage to the equipment orenvironment, or data loss.

!

Caution!Indicates a hazardous situation which, if not avoided, could result in minor or moderateinjury.

!

Warning!Indicates a hazardous situation which, if not avoided, could result in death or serious injury.

1.2 Safety precautions

!

Caution!The Low Voltage power supply unit must comply with EN/UL 60950. The power supply mustbe a SELV-LPS unit or a SELV - Class 2 unit (Safety Extra Low Voltage - Limited PowerSource).

!

Caution!Installation should only be performed by qualified service personnel in accordance withapplicable local codes.

1.3 Important safety instructionsRead, follow, and retain for future reference all of the following safety instructions. Follow allwarnings before operating the device.– Unplug the unit from the outlet before cleaning. Follow any instructions provided with the

unit.– Clean only with a dry cloth. Do not use liquid cleaners or aerosol cleaners.– Do not install device near any heat sources such as radiators, heaters, stoves, or other

equipment (including amplifiers) that produce heat.– Never spill liquid of any kind on the device.– Take precautions to protect the device from power and lightning surges.– Unless qualified, do not attempt to service a damaged device yourself. Refer all servicing

to qualified service personnel.– Install in accordance with the manufacturer's instructions in accordance with applicable

local codes.– Use only attachments/accessories specified by the manufacturer.– Protect all connection cables from possible damage, particularly at connection points.– Do not defeat the safety purpose of a polarized or ground‑type plug.– Permanently connected devices must have an external, readily operable mains plug or

all‑pole mains switch in accordance with installation rules.– Pluggable devices must have an easily accessible socket-outlet installed near the

equipment.

Page 6: DSA E‑Series (E2800 60‑bay) · – Install the unit only in a dry, weather-protected location. – Do not use this unit near water, for example near a bathtub, washbowl, sink,

6 en | Safety DSA E-Series (E2800 60-bay)

2020.11 | V2 | DOC Installation manual Bosch Security Systems B.V.

– The plug-socket combination must be accessible at all times, because it serves as themain disconnecting device.

– Any openings in the unit enclosure are provided for ventilation to prevent overheating andensure reliable operation. Do not block or cover these openings.

– Do not place the unit in an enclosure unless proper ventilation is provided, or themanufacturer's instructions have been adhered to.

– Install the unit only in a dry, weather-protected location.– Do not use this unit near water, for example near a bathtub, washbowl, sink, laundry

basket, in a damp or wet basement, near a swimming pool, in an outdoor installation, orin any area classified as a wet location.

– To reduce the risk of fire or electrical shock, do not expose this unit to rain or moisture.– Never push objects of any kind into this unit through openings as they may touch

dangerous voltage points or short-out parts that could result in a fire or electrical shock.– Power supply cords should be routed so that they are not likely to be walked on or

pinched by items placed upon or against them, playing particular attention to cords andplugs, convenience receptacles, and the point where they exit from the appliance.

– Operate the unit only from the type of power source indicated on the label. Use only thepower supply provided or power supply units with UL approval and a power outputaccording to LPS or NEC Class 2.

– Do not open or remove the cover to service this unit yourself. Opening or removing coversmay expose you to dangerous voltage or other hazards. Refer all servicing to qualifiedservice personnel.

– Be sure the service technician uses replacement parts specified by the manufacturer.Unauthorized substitutions could void the warranty and cause fire, electrical shock, orother hazards.

– Safety checks should be performed upon completion of service or repairs to the unit toensure proper operating condition.

– Observe the relevant electrical engineering regulations.– When installing in a switch cabinet, ensure that the unit and the power supply units have

sufficient grounding.– Connect the unit to an earthed mains socket.– Use proper CMOS/MOS-FET handling precautions to avoid electrostatic discharge (ESD).– For protection of the device, the branch circuit protection must be secured with a

maximum fuse rating of 16 A. This must be in accordance with NEC800 (CEC Section 60).– Disconnect the power before moving the unit. Move the unit with care. Excessive force or

shock may damage the unit and the hard disk drives.– All the input/output ports are Safety Extra Low Voltage (SELV) circuits. SELV circuits

should only be connected to other SELV circuits.– If safe operation of the unit cannot be ensured, remove it from service and secure it to

prevent unauthorized operation. In such cases, have the unit checked by Bosch SecuritySystems.

– Disconnect power supply and arrange for the device to be serviced by qualified personnelin the following cases, because safe operation is no longer possible:– The power cable/plug is damaged.– Liquids or foreign bodies have entered the device.– The device has been exposed to water or extreme environmental conditions.– The device is faulty despite correct installation/operation.– The device has fallen from a height, or the housing has been damaged.– The device was stored over a long period under adverse conditions.

Page 7: DSA E‑Series (E2800 60‑bay) · – Install the unit only in a dry, weather-protected location. – Do not use this unit near water, for example near a bathtub, washbowl, sink,

DSA E-Series (E2800 60-bay) Safety | en 7

Bosch Security Systems B.V. Installation manual 2020.11 | V2 | DOC

– The device performance is noticeably changed.– Installation of the unit must comply with local and national electrical codes.– Cluster media converters must be installed in a restricted access location.– When installing the unit into a movable cabinet or rack, install from the bottom up for

best stability.– Use only manufacturer’s supplied power cords and cables with manufacturer equipment.– DC-based systems must be installed in a restricted access location and the two input

power terminals for the DC power supply must be connected to separate isolated branchcircuits.

– A qualified service person is required to make the DC power connection according tolocal and national electric codes / guidelines.

– Ensure your DC mains supply is earthed at the point of generation per IEC 60950-1.– To reduce the risk of personal injury or equipment damage, allow internal components

time to cool before touching them.– Ensure that the equipment is properly supported or braced when installing options.– This equipment is designed for connection to a grounded outlet. The grounding type plug

is an important safety feature. To avoid the risk of electrical shock or damage to theequipment, do not disable this feature.

– Risk of electrical shock - If there is evidence of fire, water, or structural damage, neverturn on the power to the equipment.

– Risk of electrical shock - Before removing or installing a power supply, turn off the powerswitch, and unplug the power cord.

– Pinching hazard - As you push the canister into the slot, ensure that your fingers are notpinched between the lever and the canister. The lever automatically moves toward theclosed position as the canister is pushed into its slot.

– Do not remove more than one canister from the enclosure while power to the enclosureis turned on.

– Bosch products may contain Class 1 laser devices, Class 1M laser devices, or both.– Keep away from moving fan blades.– Do not use equipment in the cabinet as a shelf or work space.

1.4 Warning noticesThis product relies on the building’s installation for short-circuit (overcurrent) protection.Ensure that a fuse or circuit breaker no larger than 120 VAC, 20A U.S. (240 VAC, 16Ainternational) is used on the phase conductors (all current-carrying conductors).

!

Warning!High leakage current. Earth connection essential before connecting supply.

!

Warning!To prevent personal injury or damage to the unit, never attempt to lift or tilt the unit using thehandles of controller modules, power supplies, fans, and so on. These types of handles arenot designed to support the weight of the unit.

!

Warning!An electrical outlet that is not correctly wired could place hazardous voltage on metal parts ofthe system or the devices that attach to that system. It is the customer’s responsibility toensure that the outlet is correctly wired and grounded to prevent an electrical shock.

Page 8: DSA E‑Series (E2800 60‑bay) · – Install the unit only in a dry, weather-protected location. – Do not use this unit near water, for example near a bathtub, washbowl, sink,

8 en | Safety DSA E-Series (E2800 60-bay)

2020.11 | V2 | DOC Installation manual Bosch Security Systems B.V.

!

Warning!To prevent electrical shock hazard, disconnect all power cables from the electrical outletbefore relocating the system.

!

Warning!Risk of bodily injury, A lead-acid battery can weigh up to 10.9kg (24.1lb). When you removethis type of battery, be prepared to support its weight. If the battery is dropped, the impactmight cause bodily injury, including deep puncture wounds caused by the battery pins.

!

Warning!For Class 1M laser productsLaser radiation. Do not view directly with optical instruments. Viewing the laser output withcertain optical instruments (for example, eye loupes, magnifiers, and microscopes) within adistance of 100 mm might pose an eye hazard. Use of controls or adjustments or performanceof procedures other than those specified herein might result in hazardous radiation exposure.Do not disassemble or remove any part of a small form-factor pluggable (SFP) transceiverbecause you might be exposed to laser radiation.

1.5 Caution notices

!

Caution!The battery used in this device might present a risk of fire, explosion, or chemical burn ifmistreated. DO NOT crush or puncture, short circuit external contacts, disassemble, disposeof in fire or water, heat above maximum temperature limit, or incinerate.

!

Caution!DOUBLE POLE/NEUTRAL FUSING

!

Caution!To avoid personal injury, before lifting this unit, remove all appropriate subassemblies perinstructions to reduce the system weight.

!

Caution!Equipment weighing less than 18 kg (39.7 lbs) can be lifted by one person.Equipment weighing equal to or more than 18 kg (39.7 lbs) and less than 32 kg (70.5 lbs)requires two people to lift.Equipment weighing equal to or more than 32 kg (70.5 lbs) and less than 55 kg (121.2 lbs)requires three people to lift.Equipment weighing equal to or more than 55 kg (121.2 lbs) and less than 72 kg (158.7 lbs)requires four people to lift.Equipment weighing equal to or more than 72 kg (158.7 lbs) requires a lifting device.

1.6 Notices

iNotice!This is a class A product. In a domestic environment this product may cause radiointerference, in which case the user may be required to take adequate measures.

Page 9: DSA E‑Series (E2800 60‑bay) · – Install the unit only in a dry, weather-protected location. – Do not use this unit near water, for example near a bathtub, washbowl, sink,

DSA E-Series (E2800 60-bay) Safety | en 9

Bosch Security Systems B.V. Installation manual 2020.11 | V2 | DOC

i

Notice!Video loss is inherent to digital video recording; therefore, Bosch Security Systems cannot beheld liable for any damage that results from missing video information.To minimize the risk of losing information, we recommend multiple, redundant recordingsystems, and a procedure to back up all analog and digital information.

DisposalYour Bosch product has been developed and manufactured using high-quality materials and components that can be reused.This symbol means that electronic and electrical devices that have reachedthe end of their working life must be disposed of separately fromhousehold waste.In the EU, separate collecting systems are already in place for usedelectrical and electronic products. Please dispose of these devices at yourlocal communal waste collection point or at a recycling center.

iNotice!Do not dispose batteries in household waste. Dispose of batteries only at suitable collectionpoints and, in the case of lithium batteries, mask the poles.

!

Caution!Battery replacement - For qualified service personnel onlyA lithium battery is located inside the unit enclosure. To avoid danger of explosion, replacethe battery as per instructions. Replace only with the same or equivalent type recommendedby the manufacturer. Dispose of the replaced battery in an environmentally friendly way andnot with other solid waste. Refer all servicing to qualified service personnel.

Do not place this unit on an unstable stand, tripod, bracket, or mount. Theunit may fall, causing serious injury and/or serious damage to the unit.

Information on sales, delivery, storage, and working life periodNo restrictions or conditions apply for the sale or delivery of this product.If stored under the specified conditions, the storage period is not restricted.If used for the specified purpose in compliance with the safety instructions and technicalspecifications, the working life period of the product is in accordance with normalexpectations for this type of product.

Information on equipment useDevice is for professional installation only. Operation of the devices is not intended forpersonal or household use. There are no restrictions to use the device in commercial andindustrial areas, except those mentioned in the Safety information.

Page 10: DSA E‑Series (E2800 60‑bay) · – Install the unit only in a dry, weather-protected location. – Do not use this unit near water, for example near a bathtub, washbowl, sink,

10 en | Introducton DSA E-Series (E2800 60-bay)

2020.11 | V2 | DOC Installation manual Bosch Security Systems B.V.

2 IntroductonThis manual is written for professional system integrators and PC technicians. It providesinformation for the installation of the chassis. The installation should be done by experiencedand qualified technicians only.Before you start the installation, read and follow the safety instructions.

2.1 Hardware registrationWe recommend that you register your device. If you already have an existing NetApp NOWaccount, add your device to it. If you have no NetApp NOW account, create a new accountusing the Bosch Product Registration page.

Registering your device using an existing NetApp NOW accountSign in to your NetApp NOW account and register your device here.

Creating a new account using the Bosch Product Registration pagePlease register your product:https://www.boschsecurity.com/product-registration/

2.2 Additional equipmentYou may need the following equipment:– A Phillips No. 2 and a medium flat-blade screwdriver– An ESD wrist strap– An Ethernet switch or network hub– Ethernet cables– Management station or personal computer

2.3 Additional documentationMore informationFor more information, software downloads, and documentation, go towww.boschsecurity.com and the corresponding product page.

Page 11: DSA E‑Series (E2800 60‑bay) · – Install the unit only in a dry, weather-protected location. – Do not use this unit near water, for example near a bathtub, washbowl, sink,

DSA E-Series (E2800 60-bay) System overview | en 11

Bosch Security Systems B.V. Installation manual 2020.11 | V2 | DOC

3 System overview3.1 Device views

60-bay dual controller unit or expansion unit - front view

1 2

1 Status displays 2 Drive drawer 1 - 5 (drive drawer 1 is atthe top and drive drawer 5 is at thebottom)

60-bay dual controller unit - rear view

5 9

2

6

3

74 81

10 11 12

1 Controller A 2 Mains connection 240 VAC

3 On/off switch 4 Channel 3 (left) / Channel 4 (right) -Host interface ports (Dual 10 GBiSCSI, optical)Note: Use only RJ45 Base‑T ports oroptical ports.

Page 12: DSA E‑Series (E2800 60‑bay) · – Install the unit only in a dry, weather-protected location. – Do not use this unit near water, for example near a bathtub, washbowl, sink,

12 en | System overview DSA E-Series (E2800 60-bay)

2020.11 | V2 | DOC Installation manual Bosch Security Systems B.V.

5 Management port 1 (left) /Management port 2 (right) - Dual1 Gigabit EthernetNote: Use only Port 1 per controller(default).

6 Serial port (RJ45)

7 Serial port (mini USB) 8 USB port (only for factory use)

9 Dual 12 Gb SAS drive expansion ports 10 Status display

11 Channel 5 (left) / Channel 6 (right) -Host interface ports (Dual 10 GBiSCSI, RJ45 Base‑T)Note: Use only RJ45 Base‑T ports oroptical ports.

12 Controller B (see Controller A)

60-bay expansion unit - rear view

5 6 7

11

4

9 108 12 13 14

2 31

1 Mains connection 240 VAC 2 On/off switch

3 IOM A 4 IOM A - SAS port 1

5 IOM A - SAS port 2 6 IOM A - SAS port 3

7 IOM A - SAS port 4 8 Mains connection 100 - 240 VAC

9 On/off switch 10 IOM B

11 IOM B - SAS port 1 12 IOM B - SAS port 2

13 IOM B - SAS port 3 14 IOM B - SAS port 4

3.2 LED descriptionThere are several LEDs on the front and rear of the chassis. The LEDs show the over-all statusof the system and the activity and health of specific components.

3.2.1 LEDs on the operator display panelEach controller unit and expansion unit has LEDs located on the operator display panel. Theoperator display panel is visible through the front bezel of a controller unit and through theleft end cap of an expansion unit.

Page 13: DSA E‑Series (E2800 60‑bay) · – Install the unit only in a dry, weather-protected location. – Do not use this unit near water, for example near a bathtub, washbowl, sink,

DSA E-Series (E2800 60-bay) System overview | en 13

Bosch Security Systems B.V. Installation manual 2020.11 | V2 | DOC

1

2

3

4

5

1 7-segment display 2 Power LED

3 Attention LED 4 Locate LED

5 Drive canister

The following table describes the LEDs and their operational states:

LED Status indicator Description

Power Green One or more power supplies aresupplying power to the unit.

Off The unit is not receiving power.

Attention Amber There is an error with the function ofone or more of the following:– Unit– Drives– IOMs– Power supplies– Fans

Off The unit, drives, IOMs, power supply,and fans are functioning correctly.

Locate Blue There is an active request to physicallylocate the shelf.Note: The Locate LED turns offautomatically after 30 minutes.

3.2.2 LEDs on the controller unitThe back of the controller unit includes LEDs that indicate the status of the controller. Forexample, the controller is active, the controller needs attention, or when there is Ethernetactivity.

Page 14: DSA E‑Series (E2800 60‑bay) · – Install the unit only in a dry, weather-protected location. – Do not use this unit near water, for example near a bathtub, washbowl, sink,

14 en | System overview DSA E-Series (E2800 60-bay)

2020.11 | V2 | DOC Installation manual Bosch Security Systems B.V.

5 9

6

3 7

11

4 8

12

1

2

10

14

13 15

16

17

18

1 Channel 3 - host port link status LED 2 Channel 3 - host port attention LED

3 Channel 4 - host port link status LED 4 Channel 4 - host port attention LED

5 Management port 1 - Ethernet statusLED

6 Management port 1 - Ethernet activityLED

7 Management port 2 - Ethernet statusLED

8 Management port 2 - Ethernet activityLED

9 SAS drive expansion port - attentionLED

10 SAS drive expansion port - link statusLED

11 Cache active LED LED 12 Locate LED

13 Attention LED 14 Activity LED

The following table describes the LEDs and their operational states:

LED Status indicator Description

Cache active Green The cache contains data not yet writtento disk.

Off Either the cache is inactive or all datafrom the cache has been preserved innon-volatile memory.

Locate Blue There is an active request to physicallylocate the controller unit.

Off There is no active request to locate thecontroller unit.

Attention Amber The controller is faulty and requiresoperator attention, and the faultycomponent is serviceable.

Off The controller is operating normally.

Activity Blinking green The controller is active.

Ethernet activity (right) Green The link between the management portand the device to which it is connected(such as an Ethernet switch) is up.

Page 15: DSA E‑Series (E2800 60‑bay) · – Install the unit only in a dry, weather-protected location. – Do not use this unit near water, for example near a bathtub, washbowl, sink,

DSA E-Series (E2800 60-bay) System overview | en 15

Bosch Security Systems B.V. Installation manual 2020.11 | V2 | DOC

LED Status indicator Description

Off There is no link between the controllerand the connected Ethernet port.

Blinking green There is Ethernet activity.

Ethernet link state (left) Green Link is established.

Off No link is established.

SAS expansion port link Green Link is established.

Off No link is established.

SAS expansion port link fault Amber Port is degraded (one or more physicaldevices in the port are down).

Off Port is optimal. All physical devices inthe port are up or all physical devices inthe port are down since the LED is off ifno cables are attached.

Host port link status (SFPhost port, FC or iSCSI)

Green The link is up (Fibre channel).LED is solid: The link is up, but there isno activity (iSCSI).LED is flashing: The link is up and thereis activity (iSCSI).LED is off: The link is down.

Host port attention (SFP hostport, FC or iSCSI)

Amber The port requires operator attention.

Host port link status (RJ-45host port, iSCSI)

Green LED is on: The link is established.LED is off: No link is established.

Host port activity (RJ-45 hostport, iSCSI)

Green LED is on: The link is up with no activity.LED is blinking: There is link activity.LED is off: No link is established.

3.2.3 LEDs on the I/O modulesThe I/O module (IOM) includes the SAS ports for connecting the expansion units to thecontroller units or to other expansion units.

1

2

3

4

1 SAS port attention LED 2 SAS port link LED

Page 16: DSA E‑Series (E2800 60‑bay) · – Install the unit only in a dry, weather-protected location. – Do not use this unit near water, for example near a bathtub, washbowl, sink,

16 en | System overview DSA E-Series (E2800 60-bay)

2020.11 | V2 | DOC Installation manual Bosch Security Systems B.V.

3 IOM attention LED 4 IOM locate LED

The following table describes the LEDs and their operational states:

LED Status indicator Description

Attention Amber The IOM is not functioning correctly.

Off The IOM is functioning correctly.

Locate Blue There is an active request to physicallylocate the expansion unit.Note: When the Locate LED is activated,the Locate LED on the left end cap ofthe expansion unit is also activated.The Locate LEDs turn off automaticallyafter 30 minutes.

Off There is no active request to locate theexpansion unit.

SAS port link Green The SAS port established a link (witheither a controller or another expansionunit).

Off No link is established to another SASport.

SAS port attention Amber One or more of the links in the port arenot working properly.

Off The port is optimal and no link error hasoccurred.

3.2.4 LEDs on the drivesThe drives that are installed in the controller unit and the expansion unit include an ActivityLED and an Attention LED.

1

2

1 Activity LED 2 Attention LED

The following table describes the LEDs and their operational states:

LED Status indicator Description

Activity Green The drive has power.

Blinking green The drive has power, and I/O is inprocess.

Attention Amber An error occurred with the functioningof the drive.

Page 17: DSA E‑Series (E2800 60‑bay) · – Install the unit only in a dry, weather-protected location. – Do not use this unit near water, for example near a bathtub, washbowl, sink,

DSA E-Series (E2800 60-bay) System overview | en 17

Bosch Security Systems B.V. Installation manual 2020.11 | V2 | DOC

3.2.5 LEDs on the drive drawerEach of the 5 drive drawers in the 60-bay controller unit and the 60-bay expansion unitincludes a single Attention/Locate LED for the unit and 12 Activity LEDs for the drives.

1 5 9 136 107 112 3 4 8 12

1 Attention/Locate LED 2-13 Activity LEDs

The following table describes the LEDs and their operational states:

LED Status indicator Description

Attention/Locate LED Amber The drawer or a drive in the drawerrequires operator attention.

Off The drawer and all drives in the drawerare operating normally.

Blinking A locate operation for a drive in thedrawer is in progress.

Activity LEDs(for drives 0 through 11 in thedrive drawer)

Green The power is turned on and the drive isoperating normally.

Off The power is turned off.

Blinking Drive I/O activity is taking place.

Within a drive drawer, there are 12 drive slots numbered 0 through 11. Each drive uses anamber Attention LED that comes on if the drive requires operator attention

Page 18: DSA E‑Series (E2800 60‑bay) · – Install the unit only in a dry, weather-protected location. – Do not use this unit near water, for example near a bathtub, washbowl, sink,

18 en | System overview DSA E-Series (E2800 60-bay)

2020.11 | V2 | DOC Installation manual Bosch Security Systems B.V.

0 Attention/Locate drive LED 0 1 Attention/Locate drive LED 1

2 Attention/Locate drive LED 2 3 Attention/Locate drive LED 3

4 Attention/Locate drive LED 4 5 Attention/Locate drive LED 5

6 Attention/Locate drive LED 6 7 Attention/Locate drive LED 7

8 Attention/Locate drive LED 8 9 Attention/Locate drive LED 9

10 Attention/Locate drive LED 10 11 Attention/Locate drive LED 11

The LED status of the drives are indicated as follows:– Amber: The drive in the drawer requires operator attention.– Off: The drive in the drawer is operating normally.– Blinking: A locate operation for the drive is in progress.

3.2.6 LEDs on the power canisterThe power canister has LEDs and its own power switch and power outlet. Each 60-baycontroller unit and 60-bay expansion unit contains two power canisters.

1 2

1 Power LED 2 Attention LED

The following table describes the LEDs and their operational states:

LED icon LED name Status indicator Description

Power Steady green The power supply is functioningcorrectly.

Off The power supply failed, the AC switchis turned off, the AC power cord is notproperly installed, or the AC power cordinput voltage is not within margin (thereis a problem at the source end of the ACpower cord).

Attention Steady amber The power supply or its integrated fanhas a fault.

3.2.7 LEDs on the fan canisterThe fan canister has an Attention LED that is identified by a sideways exclamation point in themiddle of the canister. Each 60-bay controller unit and 60-expansion unit has two fancanisters, one on either side of the enclosure.

Page 19: DSA E‑Series (E2800 60‑bay) · – Install the unit only in a dry, weather-protected location. – Do not use this unit near water, for example near a bathtub, washbowl, sink,

DSA E-Series (E2800 60-bay) System overview | en 19

Bosch Security Systems B.V. Installation manual 2020.11 | V2 | DOC

1

1 Attention LEDSolid amber: The fan is faulty.

Page 20: DSA E‑Series (E2800 60‑bay) · – Install the unit only in a dry, weather-protected location. – Do not use this unit near water, for example near a bathtub, washbowl, sink,

20 en | Installation DSA E-Series (E2800 60-bay)

2020.11 | V2 | DOC Installation manual Bosch Security Systems B.V.

4 Installation4.1 Installing a 60-bay unit

You can install the unit in a four-post rack or system cabinet.Observe the following:– You can install the unit in either a square-hole or round-hole rack.– If you are installing the unit in a cabinet not provided by Bosch:

– Ensure that the rack is adequate for the weight and size of the unit to be installed.– Calculate the thermal output of your equipment and compare the results with the

target system cabinet's thermal rating. You might need to remove the system cabinetdoors to improve airflow through the system cabinet.For thermal rating information refer to the rack or system cabinet manuals providedby the manufacturer.

– You must use only the screws that are provided in the kit.

i

Notice!When installing the units, load the cabinet so as not to make it top-heavy. One approach is toplace the controller-unit in the middle portion of the cabinet while allowing room forexpansion units to be placed above and below the controller unit.

To install a 60-bay controller unit or expansion unit:1. If you are lifting and moving the unit by hand, attach the four handles. Push up on each

handle until it clicks into place.

1

2

2. Place the back of the unit (the end with the connectors) on the rails.Caution: An empty unit weighs approximately 60 kg (132 lbs). Four persons are requiredto safely move an empty unit. A fully loaded unit weighs approximately 113 kg (250 lbs). Amechanical lift is required to safely move the unit.

3. Supporting the unit from the bottom, slide the unit into the cabinet. If you are using thehandles, use the thumb latches to detach the handles as you slide the unit in.

Page 21: DSA E‑Series (E2800 60‑bay) · – Install the unit only in a dry, weather-protected location. – Do not use this unit near water, for example near a bathtub, washbowl, sink,

DSA E-Series (E2800 60-bay) Installation | en 21

Bosch Security Systems B.V. Installation manual 2020.11 | V2 | DOC

4. Secure the unit to the front of the cabinet by inserting two screws in the 1st and 3rdholes (counting down from the top) on each side.

!

4.2 Installing a 60-bay unit with SuperRailYou can install the unit in a four-post rack or system cabinet.Observe the following:– You can install the unit in either a square-hole or round-hole rack.– If you are installing the unit in a cabinet not provided by Bosch:

– Ensure that the rack is adequate for the weight and size of the unit to be installed.– Calculate the thermal output of your equipment and compare the results with the

target system cabinet's thermal rating. You might need to remove the system cabinetdoors to improve airflow through the system cabinet.For thermal rating information refer to the rack or system cabinet manuals providedby the manufacturer.

– You must use only the screws that are provided in the kit.

i

Notice!When installing the units, load the cabinet so as not to make it top-heavy. One approach is toplace the controller-unit in the middle portion of the cabinet while allowing room forexpansion units to be placed above and below the controller unit.

4.2.1 Installing SuperRail to square-hole four-post rackScope of delivery: SuperRail for square-hole four-post rack

x 2x 4

To install SuperRail to square-hole four-post rack:1. Determine where you want to install the unit in the rack or system cabinet.

Note: Whenever possible, install the units from the bottom of the rack up, so that you canuse the units underneath as a guide for installing the next set of rails.

2. Attach the rails to the rack or system cabinet as follows:– Hook in the left rail in the adapter brackets and tighten all screws completely to hold

the rail firmly in place.

Page 22: DSA E‑Series (E2800 60‑bay) · – Install the unit only in a dry, weather-protected location. – Do not use this unit near water, for example near a bathtub, washbowl, sink,

22 en | Installation DSA E-Series (E2800 60-bay)

2020.11 | V2 | DOC Installation manual Bosch Security Systems B.V.

– Repeat this step for the right rail.

1

2

1

2

3. Place the back of the unit (the end with the connectors) on the rails.Caution: An empty unit weighs approximately 60 kg (132 lbs). Four persons are requiredto safely move an empty unit. A fully loaded unit weighs approximately 113 kg (250 lbs). Amechanical lift is required to safely move the unit.

1

1

4. Carefully slide the unit all the way onto the rails.Note: If applicable, you might need to remove the end caps or the system bezel to securethe unit to the rack post. Replace the system bezel when you are done.Note: Do not place additional equipment on the rails after you finish installing the unit.The rails are not designed to bear additional weight.

Page 23: DSA E‑Series (E2800 60‑bay) · – Install the unit only in a dry, weather-protected location. – Do not use this unit near water, for example near a bathtub, washbowl, sink,

DSA E-Series (E2800 60-bay) Installation | en 23

Bosch Security Systems B.V. Installation manual 2020.11 | V2 | DOC

5. For both front rail posts: Secure the unit to the front of the rack or system cabinet andrails by inserting the screws through the holes of the unit, the holes on the rack or systemcabinet, and the holes on the front of rails.

M10x32

6. For both rear rail posts: Secure the unit to the rear of the rack or system cabinet and railsby inserting the screws through the hole of the unit, the hole on the rack or systemcabinet, and the hole on the front of rails.

M10x32

7. If applicable, replace the end caps or the system bezel.

4.2.2 Installing SuperRail to round-hole four-post rackWhen installing SuperRail on a standard round-hole four-post rack you must use the 4 round-to-square hole adapter brackets.Scope of delivery: SuperRail for round-hole four-post rack

(M4x10) x 8(M4x15) x 4 x 4Rails x 2

To install SuperRail to round-hole four-post rack:1. Determine where you want to install the unit in the rack or system cabinet.

Note: Whenever possible, install the units from the bottom of the rack up, so that you canuse the units underneath as a guide for installing the next set of rails.

Page 24: DSA E‑Series (E2800 60‑bay) · – Install the unit only in a dry, weather-protected location. – Do not use this unit near water, for example near a bathtub, washbowl, sink,

24 en | Installation DSA E-Series (E2800 60-bay)

2020.11 | V2 | DOC Installation manual Bosch Security Systems B.V.

2. Tighten the round-to-square hole adapter brackets with the screws to the four rack posts.Leave enough room for the hook-piece of the rail between the rail adapters and the rackposts.

x 4

M4x10

3. Attach the rails to the rack or system cabinet as follows:– Hook in the left rail in the adapter brackets and tighten all screws completely to hold

the rail firmly in place.– Repeat this step for the right rail.

1

2

12

M4x15

4. Place the back of the unit (the end with the connectors) on the rails.

Page 25: DSA E‑Series (E2800 60‑bay) · – Install the unit only in a dry, weather-protected location. – Do not use this unit near water, for example near a bathtub, washbowl, sink,

DSA E-Series (E2800 60-bay) Installation | en 25

Bosch Security Systems B.V. Installation manual 2020.11 | V2 | DOC

Caution: An empty unit weighs approximately 60 kg (132 lbs). Four persons are requiredto safely move an empty unit. A fully loaded unit weighs approximately 113 kg (250 lbs). Amechanical lift is required to safely move the unit.

1

1

5. Carefully slide the unit all the way onto the rails.Note: If applicable, you might need to remove the end caps or the system bezel to securethe unit to the rack post. Replace the system bezel when you are done.Note: Do not place additional equipment on the rails after you finish installing the unit.The rails are not designed to bear additional weight.

6. For both front rail posts: Secure the unit to the front of the rack or system cabinet andrails by inserting the screws through the holes of the unit, the holes of the mountingbrackets, the holes on the rack or system cabinet, and the holes on the front of rails.

M4x15

7. If applicable, replace the end caps or the system bezel.

Page 26: DSA E‑Series (E2800 60‑bay) · – Install the unit only in a dry, weather-protected location. – Do not use this unit near water, for example near a bathtub, washbowl, sink,

26 en | Installation DSA E-Series (E2800 60-bay)

2020.11 | V2 | DOC Installation manual Bosch Security Systems B.V.

4.3 Installing the drives

iNotice!To avoid damaging the hardware, never move a unit if drives are installed. Remove all drivesbefore moving the unit.

To install the drives:1. Put on the ESD wristband to protect the drives from static electricity.2. Release the levers on the top drive drawer. Then, slide the drawer out by using the levers.3. Raise the handle on the drive to vertical.

4. Starting with the leftmost slot at the front, align the two raised buttons on the drive withthe notches on the drawer. Then, pressing gently on the top of the drive, rotate the drivehandle down until the drive snaps into place.

5. Install the remaining drives. Observe the following if you are installing fewer than 60drives, SSD drives or drives with different capacities:Install drives in the front four slots of each drawer (a minimum of 20 drives in each unit)to maintain adequate airflow for cooling.– Distribute any remaining drives across the drawers. If possible, install an equal

number of each type of drive in each drawer to allow for the creation of Drawer LossProtected volume groups or disk pools.

– Distribute any SSD drives evenly across the drawers.6. Slide the drawer back in by sliding it from the center and closing both levers gently.7. Attach the bezel to the front of the unit.

4.4 Installing the front bezel and end capsA front bezel covers the front of the controller unit and the expansion unit, while left and rightend caps cover the mounting flanges on each unit.To install the front bezel:1. Position the front bezel in front of the controller unit or the expansion unit so that the

holes at each end align with the fasteners on the unit.2. Snap the bezel into place.To install the end caps:1. Position the left end cap in front of the controller unit or the expansion unit so that the

holes in the end cap align with the fasteners on the left side of the unit.2. Snap the end cap into place.3. Repeat these steps for the right end cap.

Page 27: DSA E‑Series (E2800 60‑bay) · – Install the unit only in a dry, weather-protected location. – Do not use this unit near water, for example near a bathtub, washbowl, sink,

DSA E-Series (E2800 60-bay) Installation | en 27

Bosch Security Systems B.V. Installation manual 2020.11 | V2 | DOC

4.5 Setting the unit ID using the ODP buttonYou can set or change the unit ID for a controller unit or a expansion unit by using theoperator display panel (ODP) button.

Before you beginYou might need to remove the front bezel or the end cap to see the ODP button.

About this procedureThe following figure shows the operator display panel (ODP) button on the controller unit andthe expansion unit.

1

1 Operator display panel (ODP) button

To set the unit ID with the ODP button:1. Turn on the unit.2. Press and hold the ODP button until the first number on the seven-segment display starts

to blink.Note: It can take up to three seconds for the number to blink. If the number does notblink in this time, release the button and press it again. Make sure to press the button allthe way in.

3. Change the first number of the unit ID by repeatedly pressing the ODP button to advancethe number until you reach the desired number from 0 to 9.The first number continues to blink.

4. Press and hold the ODP button until the second number on the digital display starts toblink.Note: It can take up to three seconds for the second number to blink. The first number onthe seven-segment display stops blinking.

5. Change the second number of the unit ID by repeatedly pressing the ODP button toadvance the number until you reach the desired number from 0 to 9.The second number continues to blink.

6. Lock in the desired number, and exit the programming mode by pressing and holding theODP button until the second number stops blinking.Note: It can take up to three seconds for the second number to stop blinking.

Page 28: DSA E‑Series (E2800 60‑bay) · – Install the unit only in a dry, weather-protected location. – Do not use this unit near water, for example near a bathtub, washbowl, sink,

28 en | Connection DSA E-Series (E2800 60-bay)

2020.11 | V2 | DOC Installation manual Bosch Security Systems B.V.

5 Connection5.1 Connecting the expansion units

The expansion units are shipped with the appropriate number of SAS cables.To connect the components:4 Connect the SAS cable from the SAS port on the controller unit to the SAS port on the

expansion unit.

One expansion unit - dual controller configuration

Controller

IOM

A

B

A

B

Two expansion units - two controller configuration

Controller

IOM

A

B

A

B

IOM

A

B

iNotice!You can connect a 60-bay DSA E2800 controller unit to a maximum of two 60-bay DSA E2800expansion units.

5.2 Connecting the controller unit to the networkIn case of a Bosch Video Recording Solution a host is an IP camera. To connect the controllerunit to the Ethernet one or two of two available iSCSI host ports must be connected to theEthernet. The iSCSI port connections will then be used by the IP cameras for video datatraffic.To connect the controller unit to the network:4 Connect the cable from the iSCSI host port of the controller unit to a port on the switch.

Note: Make sure that the iSCSI ports of the controller unit and the relevant IP cameraports are in the same range on the switch.

Page 29: DSA E‑Series (E2800 60‑bay) · – Install the unit only in a dry, weather-protected location. – Do not use this unit near water, for example near a bathtub, washbowl, sink,

DSA E-Series (E2800 60-bay) Connection | en 29

Bosch Security Systems B.V. Installation manual 2020.11 | V2 | DOC

Switch topology

2 3

1Switch

1 Switch 2 Controller A - iSCSI host interfaceports (RJ45 Base‑T)Note: Optionally, use the optical hostinterface ports.

3 Controller B - iSCSI host ports (RJ45Base‑T)Note: Optionally, use the optical hostinterface ports.

5.3 Connecting the controller unit to the management hostsThe management host directly manages storage arrays over an out-of-band network. Thissection describes how to set up an out-of-band connection between the Ethernet port of acontroller unit and the management host.To set up an out-of-band connection:1. Connect Ethernet cables between port 1 of controller A and port 1 of controller B to an

external Ethernet switch or hub.2. Connect the management host to the Ethernet switch or hub.

Page 30: DSA E‑Series (E2800 60‑bay) · – Install the unit only in a dry, weather-protected location. – Do not use this unit near water, for example near a bathtub, washbowl, sink,

30 en | Connection DSA E-Series (E2800 60-bay)

2020.11 | V2 | DOC Installation manual Bosch Security Systems B.V.

1

2

3

4

98

56

7

1 Private network 2 Management station or personalcomputer

3 Local Area Network (LAN) 4 Switch or hub

5 Dual controller unit 6 Controller A

7 Controller B 8 Management port 1 (Ethernet)Note: Used as default.

9 Management port 2 (Ethernet)Note: Reserved for maintenanceoperations if the hardware contains asecond Ethernet port.

iNotice!Ethernet port 2 should be reserved for maintenance operations if your hardware contains asecond Ethernet port.

5.4 Connecting the units to the power supplyTo connect the controller unit and the expansion units to the power supply:1. Confirm that the two power switches on the controller unit are off.

Note: If you have expansion units, confirm that their power switches are off.

Page 31: DSA E‑Series (E2800 60‑bay) · – Install the unit only in a dry, weather-protected location. – Do not use this unit near water, for example near a bathtub, washbowl, sink,

DSA E-Series (E2800 60-bay) Connection | en 31

Bosch Security Systems B.V. Installation manual 2020.11 | V2 | DOC

2. Connect the two power cords of the controller unit to different power distribution unitsin the cabinet or rack.Note: If you have expansion units, connect the two cords accordingly.

1

1 = Power switch3. If you have expansion units, turn on their two power switches first.

Note: Wait for 2 minutes to allow hard disks to spin up before applying power to thecontroller unit.

4. Turn on the two power switches on the controller unit and wait approximately 3 minutes.Note:– The default IP addresses will take approximately 3 minutes to initialize from the time

the network is attached.– Do not turn off the power switches during the power-on process.– The fans are very loud when they first start up. The loud noise during start-up is

normal.5. Check the LEDs and the seven-segment display on the back of each controller.

Note: The seven-segment display shows a repeating sequence (OS, Sd, blank) to indicatethat the controller is performing start-of-day processing. After the controller has started,the display shows the tray ID.

6. If any of the amber LEDs are on, there might be a problem with a component. Confirmyou completed the installation steps correctly. If you are unable to resolve the problem,contact your local Bosch Technical Support team.

5.5 Supported connectionsWe recommend using the following connection methods:

Page 32: DSA E‑Series (E2800 60‑bay) · – Install the unit only in a dry, weather-protected location. – Do not use this unit near water, for example near a bathtub, washbowl, sink,

32 en | Connection DSA E-Series (E2800 60-bay)

2020.11 | V2 | DOC Installation manual Bosch Security Systems B.V.

Default Alternatively

Controller A

Controller B LN K LN KP1 P2

0b0a

e0c e0d

LN K LN KP1 P2

0b0a

e0c e0d

1 23 4 5 6

1 23 4 5 6

LN K LN KP1 P2

0b0a

e0c e0d

LN K LN KP1 P2

0b0a

e0c e0d

1 23 4 5 6

1 23 4 5 6

1 Management port 1 (Ethernet)Note: Used as default.

2 Management port 2 (Ethernet)Note: Reserved for maintenanceoperations if the hardware contains asecond Ethernet port.

3 Channel 3 / Controller A andChannel 3 / Controller B (iSCSI,optical)

4 Channel 4 / Controller A andChannel 4 / Controller B (iSCSI,optical)

5 Channel 5 / Controller A andChannel 5 / Controller B (iSCSI, RJ45Base‑T)

6 Channel 6 / Controller A andChannel 6 / Controller B (iSCSI, RJ45Base‑T)

The Multipathing feature is enabled on dual controller units by default.Dual controller units support 2 different cabling options for the iSCSI ports.– Default: iSCSI, RJ45 Base‑T

Note:– Channel 5 / Controller B is the fallback of Channel 5 / Controller A and

Channel 6 / Controller A is the fallback of Channel 6 /. Controller B– Alternatively: iSCSI, optical

Note:– Channel 3 / Controller B is the fallback of Channel 3 / Controller A and

Channel 4 / Controller A is the fallback of Channel 4 /. Controller B

Page 33: DSA E‑Series (E2800 60‑bay) · – Install the unit only in a dry, weather-protected location. – Do not use this unit near water, for example near a bathtub, washbowl, sink,

DSA E-Series (E2800 60-bay) Turning on/off AC power | en 33

Bosch Security Systems B.V. Installation manual 2020.11 | V2 | DOC

6 Turning on/off AC power6.1 Turning on AC power

Make sure the Ethernet cable is connected to the management host. The default IP addresseswill take three minutes to initialize from the time the network is attached.The default IP addresses are:– Controller A, Port 1: 192.168.128.101– Controller B, Port 1: 192.168.128.102

iNotice!DHCP is attempted for the first three minutes of attaching the network cables. If a DHCPlease was not offered within this time, the controllers will use the default addresses.

To turn on power to the controller unit or the expansion units:1. Connect the cabinet to the power supply.2. Turn on the power distribution units of the cabinet.3. If you have expansion units, turn on their two power switches first.

Note: Wait for 2 minutes to allow hard disks to spin up before applying power to thecontroller unit.

4. Turn on the two power switches on the controller unit and wait approximately 3 minutes.Note:– The default IP addresses will take approximately 3 minutes to initialize from the time

the network is attached.– Do not turn off the power switches during the power-on process.– The fans are very loud when they first start up. The loud noise during start-up is

normal.5. Check the LEDs and the seven-segment display on the back of each controller.

Note: The seven-segment display shows a repeating sequence (OS, Sd, blank) to indicatethat the controller is performing start-of-day processing. After the controller has started,the display shows the tray ID.

6. If any of the amber LEDs are on, there might be a problem with a component. Confirmyou completed the installation steps correctly. If you are unable to resolve the problem,contact your local Bosch Technical Support team.

7. Connect all cables if required.8. Start recording of the cameras.

6.2 Turning off AC powerWe recommend turning off the system when moving the system to another location andupgrading or replacing the hardware, for example.To turn off power to the controller unit or the expansion units:1. Stop recording of the cameras and wait for 5 minutes.2. Ensure there are no background operations in progress.3. Turn off the controller-unit and wait that all LEDs are off.4. Turn off the expansion units and wait for 2 minutes to allow hard disks to spin down.5. Disconnect the cables if required.

Page 34: DSA E‑Series (E2800 60‑bay) · – Install the unit only in a dry, weather-protected location. – Do not use this unit near water, for example near a bathtub, washbowl, sink,

34 en | Configuring the storage system DSA E-Series (E2800 60-bay)

2020.11 | V2 | DOC Installation manual Bosch Security Systems B.V.

7 Configuring the storage systemThis chapter describes the basic configuration of the storage system using the ConfigurationManager program.To get a basic configuration, do the following steps:1. Start the Configuration Manager program.2. Add the device to the system.3. Create a basic configuration.

Starting the Configuration Manager programTo start the Configuration Manager program:4 Double-click the the Configuration Manager icon on the desktop.

Adding the device to the systemTo add iSCSI devices to the system:

1. On the navigation bar, click the Network Scan tab.2. Right-click a device in the tree structure, then click Add to System....

The Add Device to System dialog box appears.3. Select an existing group to assign the device to a group or leave the field empty if you do

not want to assign the device.4. Click OK. The device is added to the system.

Creating a basic configurationTo create a basic configuration:

1. On the navigation bar, click the My Devices tab.2. In the tree structure, click the corresponding device, click Pool x, click Storage Systems,

then click the storage system.3. In the view pane, click the Basic configuration tab. The basic configuration settings of the

storage system appear.4. Enter the basic settings of your storage system.5. Click Initialize. An information message box appears.6. Click Yes to confirm that you want to go on with the basic configuration. The Basic

Configuration for the iSCSI system dialog box appears. Note: The dialog box shows the status of the configuration process.

7. Click the Status tab to display the status of the configuration process.Click the Details tab to display details about all processes.Click Close to close the dialog box.

8. Click the Reload icon.9. In the tree structure, right-click the storage system, then click LUN Assignment…. The

LUN Assignment dialog box appears.Note: If multiple iSCSI ports are used, distribute the LUNs equally among the logicaliSCSI targets. Do not assign one LUN to multiple logical iSCSI targets.

10. Drag the Target x folder from the left side (Source) to the right side (VRM System), thenclick OK.

11. In the device tree, below the storage system, click Target x. In the LUNs pane to the right, all assigned LUNs appear with the status Unformatted.

Page 35: DSA E‑Series (E2800 60‑bay) · – Install the unit only in a dry, weather-protected location. – Do not use this unit near water, for example near a bathtub, washbowl, sink,

DSA E-Series (E2800 60-bay) Configuring the storage system | en 35

Bosch Security Systems B.V. Installation manual 2020.11 | V2 | DOC

12. In the LUNs pane, click Select All, then click Set. The LUNs appear with the status Taskformat and a warning message box appears that informs you that formatting a disk willdelete all data.

13. Click Yes to confirm. The status of the LUNs changes to Ready. The LUNs are formatted.

Page 36: DSA E‑Series (E2800 60‑bay) · – Install the unit only in a dry, weather-protected location. – Do not use this unit near water, for example near a bathtub, washbowl, sink,

36 en | Maintenance DSA E-Series (E2800 60-bay)

2020.11 | V2 | DOC Installation manual Bosch Security Systems B.V.

8 Maintenance8.1 Replacing a drive in a 60-bay unit

The Recovery Guru in SANtricity System Manager monitors the drives in the unit and can notifyyou of an impending drive failure or an actual drive failure. When a drive has failed, its amberAttention LED is on. You can hot-swap a failed drive while the unit is receiving I/O operations.

Before you begin– You have a replacement drive that is supported by Bosch for the controller unit or

expansion unit.– You have an ESD wristband, or you have taken other antistatic precautions.

About this procedureUse this procedure to replace a drive in the following controller units or expansion units:

Type Number of drives Type of drives

60-bay controller unit 60 3.5-inch SAS drives in carriers or 2.5-inch SASdrives in carriers60-bay expansion unit 60

The 60-bay controller unit and the 60-bay expansion unit consist of 5 drive drawers that eachcontain 12 drive slots. Drive drawer 1 is at the top, and drive drawer 5 is at the bottom. Thedrives are numbered from 0 to 11 in each drive drawer.

Rules for handling drivesThe drives are fragile. Improper drive handling is a leading cause of drive failure. Follow theserules to avoid damaging the drives in your unit:– Prevent electrostatic discharge (ESD)

– Keep the drive in the ESD bag until you are ready to install it.– Do not insert a metal tool or knife into the ESD bag. Open the ESD bag by hand or

cut the top off with a pair of scissors.– Keep the ESD bag and any packing materials in case you must return a drive later.

Page 37: DSA E‑Series (E2800 60‑bay) · – Install the unit only in a dry, weather-protected location. – Do not use this unit near water, for example near a bathtub, washbowl, sink,

DSA E-Series (E2800 60-bay) Maintenance | en 37

Bosch Security Systems B.V. Installation manual 2020.11 | V2 | DOC

– Always wear an ESD wrist strap grounded to an unpainted surface on your storageenclosure chassis. If a wrist strap is unavailable, touch an unpainted surface on yourstorage enclosure chassis before handling the drive.

– Handle drives carefully– Always use two hands when removing, installing, or carrying a drive.– Never force a drive into a unit. Use gentle, firm pressure to completely engage the

drive latch.– Place drives on cushioned surfaces, and never stack drives on top of each other.– Do not bump drives against other surfaces.– Before removing a drive, unlatch the handle and wait 30 seconds for the drive to spin

down.– Always use approved packaging when shipping drives.

– Avoid magnetic fields– Keep drives away from magnetic devices. Magnetic fields can destroy all data on the

drive and cause irreparable damage to the drive circuitry.To replace a drive observe the instructions in the following chapters:1. Preparing to replace a drive, page 372. Removing a drive, page 383. Installing a drive, page 394. After replacing a drive, page 40

8.1.1 Preparing to replace a driveBefore replacing a drive, check the Recovery Guru in SANtricity System Manager and completeany prerequisite steps. Then, you can locate the failed drive.To locate the failed drive:1. If the Recovery Guru in SANtricity System Manager has notified you of an impending drive

failure, but the drive has not yet failed, follow the instructions in the Recovery Guru to failthe drive.

2. If needed, use SANtricity System Manager to confirm you have a suitable replacementdrive.– Select Hardware.– Select the failed drive on the unit graphic.– Click the drive to display the context menu, then select View settings.– Confirm that the replacement drive has a capacity equal to or greater than the drive

you are replacing and that it has the features you expect.For example, do not attempt to replace a hard disk drive (HDD) with a solid-statedisk (SSD). Similarly, if you are replacing a secure-capable drive, make sure thereplacement drive is also secure-capable.

3. If needed, use SANtricity System Manager to locate the drive within the unit.– If the unit has a bezel, remove it so you can see the LEDs.– From the drive's context menu, select Turn on locator light.

The drive drawer's amber Attention LED blinks so you can open the correct drivedrawer to identify which drive to replace.Note: The drive drawer Attention LEDs are on the left side in front of each drive, with

Page 38: DSA E‑Series (E2800 60‑bay) · – Install the unit only in a dry, weather-protected location. – Do not use this unit near water, for example near a bathtub, washbowl, sink,

38 en | Maintenance DSA E-Series (E2800 60-bay)

2020.11 | V2 | DOC Installation manual Bosch Security Systems B.V.

an attention icon on the drive handle just behind the LED.

1

1 = Attention LED on drive drawer– Unlatch the drive drawer by pulling on both levers.– Using the extended levers, carefully pull the drive drawer out until it stops.– Look at the top of the drive drawer to find the Attention LED in front of each drive.

1

1 = Attention LED light on for the drive on the top right side.

8.1.2 Removing a driveWhen removing a drive from a 60-bay controller unit or a 60-bay expansion unit, you must liftthe drive partly out of the drawer and wait for the drive to spin down. Then, you can removethe drive completely.Before you begin:– You have an ESD wristband, or you have taken other antistatic precautions.– You have reviewed the Rules for handling drives, page 36.To remove a drive:1. Unpack the replacement drive, and set it on a flat, static-free surface near the unit. Save

all packing materials for the next time you need to send a drive back.2. If you have not already done so, release the drive drawer levers from the center of the

appropriate drive drawer by pulling both towards the sides of the drawer.3. If you have not already done so, carefully pull on the extended drive drawer levers to pull

out the drive drawer to its full extension without removing it from the enclosure.

Page 39: DSA E‑Series (E2800 60‑bay) · – Install the unit only in a dry, weather-protected location. – Do not use this unit near water, for example near a bathtub, washbowl, sink,

DSA E-Series (E2800 60-bay) Maintenance | en 39

Bosch Security Systems B.V. Installation manual 2020.11 | V2 | DOC

4. Gently pull back the orange release latch that is in front of the drive you want to remove.The cam handle on the drive springs open partially, and the drive is released from thedrawer.

1

1 = Orange release latch5. Open the cam handle, and lift out the drive slightly.6. Wait 30 seconds.7. Use the cam handle to lift the drive from the unit.

8. Place the drive on an antistatic, cushioned surface away from magnetic fields.9. Wait 30 seconds for the software to recognize that the drive has been removed.

iNotice!If you accidentally remove an active drive, wait at least 30 seconds, and then reinstall it. Forthe recovery procedure, refer to the storage management software.

8.1.3 Installing a driveInstall the replacement drive as soon as possible after removing the failed drive. Otherwise,there is a risk that the equipment might overheat.To install a drive:1. Raise the cam handle on the new drive to vertical.

Page 40: DSA E‑Series (E2800 60‑bay) · – Install the unit only in a dry, weather-protected location. – Do not use this unit near water, for example near a bathtub, washbowl, sink,

40 en | Maintenance DSA E-Series (E2800 60-bay)

2020.11 | V2 | DOC Installation manual Bosch Security Systems B.V.

2. Align the two raised buttons on each side of the drive carrier with the matching gap in thedrive channel on the drive drawer.

1

1 = Raised button on the right side of the drive carrier3. Lower the drive straight down, and then rotate the cam handle down until the drive snaps

into place under the orange release latch.4. Carefully push the drive drawer back into the unit.

Note: Possible loss of data access: Never slam the drawer shut. Push the drawer in slowlyto avoid jarring the drawer and causing damage to the unit.

5. Close the drive drawer by pushing both levers towards the center.The green Activity LED for the replaced drive on the front of the drive drawer comes onwhen the drive is inserted correctly.Note: Depending on your configuration, the controller might automatically reconstructdata to the new drive. If the unit uses hot spare drives, the controller might need toperform a complete reconstruction on the hot spare before it can copy the data to thereplaced drive. This reconstruction process increases the time that is required tocomplete this procedure.

8.1.4 After replacing a driveAfter replacing a drive, you must confirm that the new drive is working correctly.To confirm that the new drive is working correctly:1. Check the Activity LED and the Attention LED on the drive you replaced.

LED status Description

The Activity LED is on or blinking, and theAttention LED is off.

The new drive is working correctly.

The Activity LED is off. The drive might not be installed correctly.Remove the drive, wait 30 seconds, and thenreinstall it.

The drive drawer’s Attention LED is on. The new drive might be defective. Replace itwith another new drive.

Page 41: DSA E‑Series (E2800 60‑bay) · – Install the unit only in a dry, weather-protected location. – Do not use this unit near water, for example near a bathtub, washbowl, sink,

DSA E-Series (E2800 60-bay) Maintenance | en 41

Bosch Security Systems B.V. Installation manual 2020.11 | V2 | DOC

LED status Description

Note: When you first insert a drive, itsAttention LED might be on. However, the LEDshould go off within a minute.

2. If the Recovery Guru in SANtricity System Manager still shows an issue, select Recheck toensure the problem has been resolved.

3. If the Recovery Guru indicates that drive reconstruction did not start automatically, startreconstruction manually, as follows:Note: Perform this operation only when instructed to do so by technical support or theRecovery Guru.– Select Hardware.– Click the drive that you replaced.– From the drive's context menu, select Reconstruct.– Confirm that you want to perform this operation.

When the drive reconstruction completes, the volume group is in an optimal state.4. As required, reinstall the bezel on the front of the unit.5. Return the failed part to Bosch, as described in the RMA instructions shipped with the

kit.

8.2 Replacing a power canisterEach 60-bay controller unit or 60-bay expansion unit includes 2 power canisters for powerredundancy. If a power canister fails, replace the power canister as soon as possible to ensurethat the unit has a redundant power source.

Before you begin– You have a replacement power canister that is supported for your controller unit or

expansion unit model.– You have one power canister that is installed and running.– You have an ESD wristband, or you have taken other antistatic precautions.

About this procedureUse this procedure to replace a power canister in the following units:– 60-bay E2800 controller unit– 60-bay E2800 expansion unit

Rear view - 60-bay controller unit (left) / 60-bay expansion unit (right)

1 1

1 Power canister

You can replace a power canister while your storage array is powered on and performing hostI/O operations, as long as the following conditions are true:– The other power canister in the unit has Optimal status.

Note: While you perform the procedure, the second power canister supplies power toboth fans to ensure that the equipment does not overheat.

Page 42: DSA E‑Series (E2800 60‑bay) · – Install the unit only in a dry, weather-protected location. – Do not use this unit near water, for example near a bathtub, washbowl, sink,

42 en | Maintenance DSA E-Series (E2800 60-bay)

2020.11 | V2 | DOC Installation manual Bosch Security Systems B.V.

– The OK to remove field in the Details area of the Recovery Guru in SANtricity SystemManager displays Yes, indicating that it is safe to remove this component.

iNotice!If the second power canister in the unit does not have Optimal status or if the Recovery Guruindicates that it is not OK to remove the power canister, contact your technical support..

To replace a power canister observe the instructions in the following chapters:1. Preparing to remove a power canister, page 422. Removing a power canister, page 433. Installing a power canister, page 434. After replacing a power canister, page 43

8.2.1 Preparing to remove a power canisterBefore you remove a power canister, use SANtricity System Manager to collect support dataabout your storage system and to locate the failed component.You can determine whether you have a failed power canister in these ways:– The Recovery Guru in SANtricity System Manager directs you to replace a failed power

canister. Before replacing a power canister, select Recheck from the Recovery Guru toensure that no other items must be addressed first.

– The amber Attention LED on the power canister is on, indicating that the component isfaulty.Note: If both power canisters in the shelf have their Attention LEDs on, contact technicalsupport for assistance.

To prepare the removing of the component:1. Collect support data for your storage system (see Collecting support data for the storage

system, page 51).Note: Collecting support data before and after replacing a component ensures you cansend a full set of logs to technical support in case the replacement does not resolve theproblem.

2. From SANtricity System Manager, determine which power canister has failed.– Select Hardware.

– Look at the power icon to the right of the Shelf lists to determine which shelfhas the failed power canister. If a component has failed, this icon will be red.

– When you find the shelf with a red icon, select Show back of shelf.– Select either power canister or the red power icon.– On the Power Supplies tab, look at the statuses of the power canisters to determine

which power canister must be replaced. A component with a Failed status must bereplaced.Note: If the second power canister in the shelf does not have Optimal status, do notattempt to hot-swap the failed power canister. Instead, contact technical support forassistance.You can also find information about the failed power canister in the Details area ofthe Recovery Guru, or you can review the information displayed for the shelf, or youcan review the Event Log under Support and filter by Component Type.

Page 43: DSA E‑Series (E2800 60‑bay) · – Install the unit only in a dry, weather-protected location. – Do not use this unit near water, for example near a bathtub, washbowl, sink,

DSA E-Series (E2800 60-bay) Maintenance | en 43

Bosch Security Systems B.V. Installation manual 2020.11 | V2 | DOC

3. From the back of the storage array, look at the Attention LEDs to locate the powercanister you need to remove. You must replace the power canister that has its AttentionLED on.

Refer to– LEDs on the power canister, page 18

8.2.2 Removing a power canisterTo remove a power canister:1. Put on antistatic protection.2. Unpack the new power canister and place it on a level surface near the unit.

Save all packing materials for use when returning the failed power canister.3. Turn off the power switch on the power canister that you need to remove.4. Open the power cord retainer of the power canister that you need to remove, then unplug

the power cord from the power canister.5. Press the orange latch on the power canister cam handle, then open the cam handle to

fully release the power canister from the mid plane.6. Use the cam handle to slide the power canister out of the unit.

Note: When removing a power canister, always use two hands to support its weight.

8.2.3 Installing a power canisterTo install a power canister:1. Make sure that the on/off switch of the new power canister is in the Off position.2. Using both hands, support and align the edges of the power canister with the opening in

the system chassis, then gently push the power canister into the chassis using the camhandle until it locks into place.Note: Do not use excessive force when sliding the power canister into the chassis; youcan damage the connector.

3. Close the cam handle so that the latch clicks into the locked position and the powercanister is fully seated.

4. Reconnect the power cord to the power canister, and secure the power cord to thepower canister using the power cord retainer.

5. Turn on the power to the new power canister.

8.2.4 After replacing a power canisterAfter replacing a power canister, you must confirm that the new power canister is workingcorrectly. Then, you can gather support data and resume operations.To confirm that the new power canister is working correctly:1. Check the green Power LED and the amber Attention LED on the new power canister.

The Power LED must be on and the Attention LED must be off (see LEDs on the powercanister, page 18).

2. From the Recovery Guru in SANtricity System Manager, select Recheck to ensure theproblem has been resolved.

3. If a failed power canister is still being reported, repeat the steps in Removing a powercanister, page 43 and Installing a power canister, page 43. If the problem continues topersist, contact technical support.

Page 44: DSA E‑Series (E2800 60‑bay) · – Install the unit only in a dry, weather-protected location. – Do not use this unit near water, for example near a bathtub, washbowl, sink,

44 en | Maintenance DSA E-Series (E2800 60-bay)

2020.11 | V2 | DOC Installation manual Bosch Security Systems B.V.

4. Remove the antistatic protection.5. Collect support data for your storage system (see Collecting support data for the storage

system, page 51).Note: Collecting support data before and after replacing a component ensures you cansend a full set of logs to technical support in case the replacement does not resolve theproblem.

6. Return the failed part as described in the RMA instructions shipped with the kit.

8.3 Replacing a fan canisterEach 60-bay controller unit or 60-bay expansion unit includes two fan canisters. If a fancanister fails, you, replace the fan canister as soon as possible to ensure that the unit hasadequate cooling.

Before you begin– You have a replacement fan canister (fan) that is supported for your controller unit or

expansion unit model.– You have one fan canister that is installed and running.– You have an ESD wristband, or you have taken other antistatic precautions.

About this procedureUse this procedure to replace a fan canister in the following units:– 60-bay E2800 controller unit– 60-bay E2800 expansion unit

iNotice!Possible equipment damage - If you perform this procedure with the power turned on, youmust complete it within 30 minutes to prevent the possibility of overheating the equipment.

Rear view - 60-bay controller unit (left) / 60-bay expansion unit

1 1 1 1

1 Fan canister

You can replace a fan canister while your storage array is turned on and performing host I/Ooperations, as long as the following conditions are true:– The other fan canister in the unit has Optimal status.– The OK to remove field in the Details area of the Recovery Guru in SANtricity System

Manager displays Yes, indicating that it is safe to remove this component.

iNotice!If the second fan canister in the unit does not have Optimal status or if the Recovery Guruindicates that it is not OK to remove the fan canister, contact your technical support.

To replace a fan canister observe the instructions in the following chapters:

Page 45: DSA E‑Series (E2800 60‑bay) · – Install the unit only in a dry, weather-protected location. – Do not use this unit near water, for example near a bathtub, washbowl, sink,

DSA E-Series (E2800 60-bay) Maintenance | en 45

Bosch Security Systems B.V. Installation manual 2020.11 | V2 | DOC

1. Preparing to remove a fan canister, page 452. Removing and replacing a fan canister, page 463. After replacing a fan canister, page 46

8.3.1 Preparing to remove a fan canisterBefore removing a fan canister, use SANtricity System Manager to collect support data aboutyour storage system and to locate the failed component.You can determine whether you have a failed fan canister in these ways.– The Recovery Guru in SANtricity System Manager directs you to replace a failed fan

canister.Note: Before replacing a fan canister, select Recheck from the Recovery Guru to ensurethat no other items must be addressed first.

– The amber Attention LED on the fan canister is on, indicating that the fan is faulty.Note: If both fan canisters in the unit have their Attention LEDs on, contact technicalsupport for assistance.

To prepare the removing of the component:1. Collect support data for your storage system (see Collecting support data for the storage

system, page 51).Note: Collecting support data before and after replacing a component ensures you cansend a full set of logs to technical support in case the replacement does not resolve theproblem.

2. From SANtricity System Manager, determine which fan canister has failed.– Select Hardware.

– Look at the fan icon to the right of the Shelf lists to determine which shelf hasthe failed fan canister. If a component has failed, this icon is red.

– When you find the shelf with a red icon, select Show back of shelf.– Select either fan canister or the red fan icon.– On the Fans tab, look at the statuses of the fan canisters to determine which fan

canister must be replaced. A component with a Failed status must be replaced.Note: If the second fan canister in the shelf does not have Optimal status, do notattempt to hot-swap the failed fan canister. Instead, contact technical support forassistance.You can also find information about the failed fan canister in the Details area of theRecovery Guru, or you can review the Event Log under Support and filter byComponent Type.

3. From the back of the storage array, look at the Attention LEDs to locate the fan canisteryou need to remove. You must replace the fan canister that has its Attention LED on.

1

Page 46: DSA E‑Series (E2800 60‑bay) · – Install the unit only in a dry, weather-protected location. – Do not use this unit near water, for example near a bathtub, washbowl, sink,

46 en | Maintenance DSA E-Series (E2800 60-bay)

2020.11 | V2 | DOC Installation manual Bosch Security Systems B.V.

1 Attention LEDSolid amber: The fan is faulty.

8.3.2 Removing and replacing a fan canisterWhen you remove the failed fan canister, you do not have to turn off power to your storagearray. You must ensure that you remove and replace the fan canister within 30 minutes toprevent the system from overheating.To remove and replace a fan canister:1. Put on antistatic protection.2. Unpack the new fan canister, and place it on a level surface near the unit.

Save all packing material for use when returning the failed fan.3. Press the orange release button to release the fan canister handle.

1

1 = Release button4. Use the fan canister handle to pull the fan canister out of the unit.

1

1 = Fan canister handle5. Slide the replacement fan canister all the way into the unit, and then move the fan

canister handle until it latches with the orange release button.

8.3.3 After replacing a fan canisterAfter replacing a fan canister, you must confirm that the new fan canister is working correctly.Then, you can gather support data and resume operations.To confirm that the new fan-canister is working correctly:1. Check the amber Attention LED on the new fan canister.

Note: After you have replaced the fan canister, the Attention LED shows a steady ambercolor while the firmware checks that the fan canister was installed correctly. The LEDgoes off after this process is complete.

2. From the Recovery Guru in SANtricity System Manager, select Recheck to ensure theproblem has been resolved.

Page 47: DSA E‑Series (E2800 60‑bay) · – Install the unit only in a dry, weather-protected location. – Do not use this unit near water, for example near a bathtub, washbowl, sink,

DSA E-Series (E2800 60-bay) Maintenance | en 47

Bosch Security Systems B.V. Installation manual 2020.11 | V2 | DOC

3. If a failed fan canister is still being reported, repeat the steps in Removing and replacing afan canister on page 4. If the problem continues to persist, contact technical support.

4. Remove the antistatic protection.5. Collect support data for your storage array (see Collecting support data for the storage

system, page 51).Note: Collecting support data before and after replacing a component ensures you cansend a full set of logs to technical support in case the replacement does not resolve theproblem.

6. Return the failed part as described in the RMA instructions shipped with the kit.

8.4 Seven-segment display codesThe following chapters explain the codes that are displayed on the seven-segment-display.– Seven-segment display sequence codes, page 47– Seven-segment display codes when controller turns on, page 48– Seven-segment display use cases, page 48– Seven-segment display lock-down codes, page 50

8.4.1 Seven-segment display sequence codesSeven-segment display sequences enable you to understand errors and operational states ofthe various components in your storage array. Each sequence shows a two-digit categorycode, followed by a two-digit detail code. The category code appears at the start of asequence and the detail code follows the category code with more specific information aboutthe error. After each category code is displayed, the LED goes blank. Then the detail codeappears and disappears, and the entire sequence is repeated. For example, if there is apower-on validation error during startup, you see the following codes displayed on the seven-segment display: SE, followed by Sx, in which SE is the category code and Sx is the detailcode.When the seven-segment display sequence starts, the Diagnostic LED is on (green).The following table includes the seven-segment display sequence codes and descriptions:

Category Category code Detail code

Startup error SE – 88: Power-on default– dF: Power-on diagnostic fault– Sx: Power-on validation error

Operational error OE – Lx: Lock-down codesSee Seven-segment display lock-downcodes.

Operational state OS – OL: Offline– bb: Battery backup (operating on

batteries)– OH: CPU temperature exceeds the

warning level– CF: Component failure

Component failure CF – dx: Processor or cache DIMM– Cx: Cache DIMM– Px: Processor DIMM– Hx: Host interface card– Fx : Flash drive

Page 48: DSA E‑Series (E2800 60‑bay) · – Install the unit only in a dry, weather-protected location. – Do not use this unit near water, for example near a bathtub, washbowl, sink,

48 en | Maintenance DSA E-Series (E2800 60-bay)

2020.11 | V2 | DOC Installation manual Bosch Security Systems B.V.

Category Category code Detail code

– bl: Base controller card

Diagnostic failure dE – Lx: Lock-down codes– See Seven-segment display lock-

down codes.

Category delimiter --Note: The doublehyphen (--) is theseparator betweencategorydetailcode pairs whenmore than one pairexists in thesequence.

End-of-sequence delimiter Blank: The displayturns off at the endof a sequence.

8.4.2 Seven-segment display codes when controller turns onThe following table describes the seven-segment codes that are displayed when the controllerturns on:

Code Description

0xEA DDR4 training failed

0xE8 No memory installed

0x22 No master boot record found on any bootdevice

0x23 No SATA drive installed

0xAE Booting OS

0xAB Alternate boot code

0x40 Invalid DIMMs

0x41 Invalid DIMMs

0x42 Memory test failed

0x2A, 0x2B Stuck bus, unable to read DIMM SPD data

0x51 DIMM SPD read failure

0xA0, 0xA1, 0xA2, and 0xA3 SATA drive initialization

0x92 - 0x96 PCI bus initialization

8.4.3 Seven-segment display use casesThe following table shows seven-segment display use cases and the sequence that isdisplayed in each case:

Page 49: DSA E‑Series (E2800 60‑bay) · – Install the unit only in a dry, weather-protected location. – Do not use this unit near water, for example near a bathtub, washbowl, sink,

DSA E-Series (E2800 60-bay) Maintenance | en 49

Bosch Security Systems B.V. Installation manual 2020.11 | V2 | DOC

Use case Display sequence

Controller power-on

– Normal power-on controller insertion SE 88 blank

– Controller inserted while held in reset

Operational states

Normal operation xy (static controller tray ID)

Start-of-day (SOD) processing OS Sd blank

The controller is placed in reset whileshowing the tray ID

OS OL blank

The controller is operating on batteries(cache backup)

OS bb blank

The CPU temperature has exceeded thewarning level

OS OH blank

Component failure when the controller is operational

Failed host interface card (HIC) OS CF HX blank

Failed flash drive OS CF Fx blank

Power-on diagnostic failure

Failure of a component that is not a fieldreplaceable unit

SE dF blank-

Processor DIMM failure SE dF -- CF Px blank-

Cache memory DIMM failure SE dF -- CF Cx blank-

Processor DIMM or cache memory DIMMfailure

SE dF -- CF dx blank-

Host interface card failure SE dF -- CF Hx blank-

Incorrect number of cache backup devices SE LC -- CF Fx blank-

The controller is suspended and there are no other errors to report

All lock-down conditions OH Lx blank

The controller is suspended because of component errors

Persistent processor DIMM error correctingcode (ECC) errors

OE L2 -- CF Px blank-

Persistent cache DIMM ECC errors OE L2 -- CF Cx blank-

Persistent processor or cache DIMM ECCerrors

OE L2 -- CF dx blank-

The controller is suspended as a result of persistent cache backup configuration errors

The write-protect switch is set during cacherestore

OE LC blank-

Page 50: DSA E‑Series (E2800 60‑bay) · – Install the unit only in a dry, weather-protected location. – Do not use this unit near water, for example near a bathtub, washbowl, sink,

50 en | Maintenance DSA E-Series (E2800 60-bay)

2020.11 | V2 | DOC Installation manual Bosch Security Systems B.V.

Use case Display sequence

The memory size changed with dirty data inthe flash drives

OE L2 -- CF dx blank-

The controller is suspended as a result of diagnostic errors

Cache memory diagnostic failure dE L2 -- CF Cx blank-

Base controller diagnostic failure dE L3 -- CF b1 blank-

Base controller I/O Controller chip (IOC)diagnostic failure

dE L3 -- CF b2 blank-

8.4.4 Seven-segment display lock-down codesDiagnostic lock-down codes are displayed when the controller is not operational, eitherbecause of a configuration problem or a hardware fault. The lock-down code is displayed aspart of the seven-segment display sequence.The following table includes the lock-down codes and describes the conditions that cause thecontroller to be in a suspended state:

Lock-down code Description

L0 The controller types in a duplex configurationare mismatched.

L1 Missing interconnect canister.

L2 A persistent memory error has occurred.

L3 A persistent hardware error has occurred.

L4 A persistent data protection error hasoccurred.

L5 An auto-code synchronization (ACS) failurehas been detected.

L6 An unsupported HIC has been detected.

L7 A sub-model identifier either has not been setor has been mismatched.

L8 A memory configuration error has occurred.

L9 A link speed mismatch condition has beendetected in either the I/O module (IOM) orthe power supply.

Lb A HIC configuration error has been detected.

LC A persistent cache backup configuration errorhas been detected.

Ld A mixed cache memory DIMMs condition hasbeen detected.

LE Uncertified cache memory DIMM sizes havebeen detected.

Page 51: DSA E‑Series (E2800 60‑bay) · – Install the unit only in a dry, weather-protected location. – Do not use this unit near water, for example near a bathtub, washbowl, sink,

DSA E-Series (E2800 60-bay) Maintenance | en 51

Bosch Security Systems B.V. Installation manual 2020.11 | V2 | DOC

Lock-down code Description

LF The controller has locked down in asuspended state with limited SYMbolsupport.

LH A controller firmware mismatch has beendetected.

LJ The controller does not have enough memoryto support the configuration.

LL The controller cannot access either midplaneSBB EEPROM.

Ln A module is not valid for a controller.

LP Drive port mapping tables are not detected.

Lr A component that is not a field replaceableunit (FRU) has been replaced.

Lt A configuration data base corruption hasbeen detected.

LU The SOD reboot limit has been exceeded.

In some cases, controllers detect errors during the startup process.The following table describes seven-segment startup errors and conditions that result in thecontroller being in a suspended state:

Startup error code Description

S1 The controller detects a checksum failure inEEPROM.

S2 The SBB Signature/Revision is invalid.

S3 An unsupported enclosure is detected in thestorage array.

S4 The power supplies are incapable ofpowering the controller.

S5 The SBB pairing has failed.

8.5 Collecting support data for the storage systemThe following procedures describe how to collect support data for the storage system usingSANtricity System Manager and Script editor in the Enterprise Management Window (EMW).

Collecting support data using SANtricity System Manager1. Select Support > Support Center > Diagnostics.2. Select Collect Support Data.3. Click Collect.

The file is saved in the Downloads folder for your browser with the namesupportdata.7z

Collecting support data using Script editor in the EMW1. Open the Enterprise Management Window (EMW) in SANtricity Storage Manager on your

local host.

Page 52: DSA E‑Series (E2800 60‑bay) · – Install the unit only in a dry, weather-protected location. – Do not use this unit near water, for example near a bathtub, washbowl, sink,

52 en | Maintenance DSA E-Series (E2800 60-bay)

2020.11 | V2 | DOC Installation manual Bosch Security Systems B.V.

2. Select the storage system.3. Select Tools > Execute Script.4. Type the following command in the text box.

save storageArray supportData file="filename";In this command, filename is the file path and the file name to which you want to savethe support data. Enclose the file path and the file name in double quotation marks (" ").For example:file="C:\Program Files\CLI\logs\support-data.7z"

5. Select Tools > Verify and Execute

Page 53: DSA E‑Series (E2800 60‑bay) · – Install the unit only in a dry, weather-protected location. – Do not use this unit near water, for example near a bathtub, washbowl, sink,

DSA E-Series (E2800 60-bay) Support services and Bosch Academy | en 53

Bosch Security Systems B.V. Installation manual 2020.11 | V2 | DOC

9 Support services and Bosch Academy

SupportAccess our support services at www.boschsecurity.com/xc/en/support/.Bosch Security and Safety Systems offers support in these areas:– Apps & Tools– Building Information Modeling– Commissioning– Warranty– Troubleshooting– Repair & Exchange– Product Security

Bosch Building Technologies AcademyVisit the Bosch Building Technologies Academy website and have access to training courses,video tutorials and documents: www.boschsecurity.com/xc/en/support/training/

Page 54: DSA E‑Series (E2800 60‑bay) · – Install the unit only in a dry, weather-protected location. – Do not use this unit near water, for example near a bathtub, washbowl, sink,

54 | Support services and Bosch Academy DSA E-Series (E2800 60-bay)

2020.11 | V2 | DOC Installation manual Bosch Security Systems B.V.

Page 55: DSA E‑Series (E2800 60‑bay) · – Install the unit only in a dry, weather-protected location. – Do not use this unit near water, for example near a bathtub, washbowl, sink,
Page 56: DSA E‑Series (E2800 60‑bay) · – Install the unit only in a dry, weather-protected location. – Do not use this unit near water, for example near a bathtub, washbowl, sink,

Bosch Security Systems B.V.Torenallee 495617 BA EindhovenNetherlandswww.boschsecurity.com© Bosch Security Systems B.V., 2020

202011201125


Recommended