+ All Categories
Home > Documents > DTX CableAnalyzer. - Solarlegacy.solar.dk/upload/downloads/installation/JP.pdf · FlukeDSP4x00 og...

DTX CableAnalyzer. - Solarlegacy.solar.dk/upload/downloads/installation/JP.pdf · FlukeDSP4x00 og...

Date post: 03-Apr-2018
Category:
Upload: trinhdung
View: 227 times
Download: 4 times
Share this document with a friend
33
DTX CableAnalyzer.
Transcript

DTX CableAnalyzer.

Physical Characteristics

Bright color display

Soft key labels (e.g. Fault Info)

Keypad and rotary knob make learning easy

Power On buttonTalk button

Test

High performance connector for Copper adapters

MMC card slot

USB and Serial Interface connectors

Rugged overmoldbonded to case

M: 1.1kg

R:0.9kg

0.6kg Battery

10.1x5x2.3

4-8 hours

Adapter

Limited

Level III

Color

350

33 sec

Lantek 6P

M: 1.1kg

R:0.9kg

0.6kg Battery

10.1x5x2.3

4-8 hours

Adapter

Limited

Level III

Color

750

33 sec

Lantek 7P

M: 1.4kg

R: 1.4kg

9x4.5x2.6

5-6 hours

Adapter

Limited

Level III

Color

350

40 sec

Wirescope350

10 hours12 hours12 hours12 hoursBattery Life

M: 1.9kg

R: 1.8kg

11x5x3

Adapter

Advance Traces

Level III

Black & White

350

35 sec

DSP-4300

M: 1.2kg

R: 1.2kg

M: 1.2kg

R: 1.2kg

M: 1.2kg

R: 1.2kgWeight

10.5x4.4x2.510.5x4.4x2.510.5x4.4x2.5Dimensions (in)

On-BoardOn-BoardOn-BoardFiber Testing

Directions for Corrective

Actions

Directions for Corrective

Actions

Directions for Corrective

ActionsDiagnostics

Level IVLevel IVLevel IVAccuracy

ColorColorColorDisplay Type

350350900Frequency (MHz)

30 sec12 sec12 secCat 6 Autotest Time

DTX-LTDTX-1200DTX-1800Tester

Features

DTX Choice of Models

Summary: DTX-1200 vs. DSP-4300

$47Kx4x3 = $564K$35Kx4x3 +$6Kx4 = $444KTotal Cost of Ownership – 3 years

$47Kx4= $188K$35Kx4 + $6Kx4 = $164KTotal Cost of Ownership – 1 year/4 testers

10.5 hours/day x 6 days/month x 12 months x $65/hour = $47K

7.5 hours/day x 6 days/month x 12 months x $65/hour = $35K

Total Cost To Certify per Year for 1 tester

3 hours + 3.5 hours + 3.8 hours = 10.1 hours1 hour + 3.5 hours + 3 hours = 7.3 hoursTotal Time To Certify per Day

15 links/2 x 20 min +

15 links/2 x 10 min =

3.8 hours

15 links/2 x 15 min +

15 links/2 x 10 min =

3 hours

Troubleshoot time per 300 links

300 links x 5% = 15 links300 links x 5% = 15 links# of failed links per 300 links

40 sec x 300 links x 1hr/3600 sec = 3.3 hrs40 sec x 300 links x 1hr/3600 sec = 3.3 hrsMove Time/

300 links

35 sec x 300 links x 1hr/3600 = 3 hours12 sec x 300 links x 1hr/3600 sec = 1 hourAutotest Time/

300 links

DSP-4300DTX-1200

Fiber moduler til DTX

Each multimode module 850nm and 1300nm LED

sources

DTX-SINGLEMODE

DTX-SINGLEMODE

Each singlemode module 1310nm and 1550nm laser

sources

Insert and leave

Switch between copper and fiber media with a button push

5 measurements in 12 seconds

• DTX fiber modules make 5 measurements every Autotest compared to competitive adapters that make 3 measurements

• DTX fiber modules measure more in less time– 12 second Autotest is 5X faster than competitive

adapters

•Gratis kalibrering en gang om året

•Låneinstrument

•Garantiperioden forlænges

•Pris 6.416kr. netto inst.

Principle of Fusion Splicing

y

zfiber 2

electrode

fiber 1

electric arcabout 3000ºF

or 1800C

core

claddingcoating

electrode

alignment

alignment

z

x

Splicing can be done:

1. In a „Splice Truck“

Splicing can be done:

1. In a „Splice Truck“

Field Splicing with a Fusion Splicer

Splicing can be done:

1. In a „Splice Truck“

2. Inside of Buildings

Splicing can be done:

1. In a „Splice Truck“

2. Inside of Buildings

Splicing can be done:

1. In a „Splice Truck“

2. Inside of Buildings

3. At Sunny Weather

Splicing can be done:

1. In a „Splice Truck“

2. Inside of Buildings

3. In Sunny Weather

Splicing can be done:

1. In a „Splice Truck“

2. Inside of Buildings

3. In Sunny Weather

4. In Nasty Weather

Splicing can be done:

1. In a „Splice Truck“

2. Inside of Buildings

3. In Sunny Weather

4. In Nasty Weather

5. In Men-Holes

Microprocessor

Z

Cameras

Z

P

Video I mage Evaluation L-PAS®®

Types of Fusion Splicers

• Single Fiber

– Core Aligning (3 Axis positioning)

– Fixed V-Groove

• Ribbon

– Fixed V-Groove

– Splice 1-24 fibers Simultaneously

– Productivity over Performance

X77: Excellent Price/Performance Relation• Precise core-to-core alignment by 1300 nm LID-

System®.

• High-resolution video image evaluation L-PAS®

• P&D-Electrodes

• High-contrast 5.5” color LCD-display

• Splice loss optimization of each individual splice process by AFC®

• Attenuation splice function

• LEAF and TrueWave splice programs

• Self-controlled tensile test capability

• RS232 interface for downloading splice lossvalues and program parameters

Fusion splicer X77 with heat-shrink oven and splice tray holder

• For standard single-mode and multimode fibers

• Cleave angle deviation typically 0.5°

• Easy and fast cleaving operation

• Typically more than 10,000 cleaves per blade

0

50

100

150

200

250

300

0,1 0,2 0,3 0,4 0,5 0,6 0,7 0,8 0,9cleave angle in °

freq

uenc

y

Distribution of cleave angle deviationFiber optic cleaver A8

Workstation

Workstation for X77 and X75

• Provides optimum protection of fusion splicer

• Includes more the power options like rechargable 6.5 Ah

battery

• Integrated power supply

• Perfect solution for robust field fusion splicing

Den perfekt verden...

TX

Fiberkabling

RX

...findes ikke !

TX RXFast installation

PatchkabelPatchkabel

Fiberbox Fiberbox

• Fiberkabel

• Konnekteringer

• Splidsninger

...er alt sammen med til at forværre kommunikationen

• Bøjninger på kabel

• Beskidte konnektore

• Mismatch

Patch Panel 1

Fiber SystemUnder Test

Launch Test Fiber BoxPlaces Distance between OTDR

and Fiber Under Test

OTDRLaver en grafisk afbildning af retursignal i forhold til længdeLokaliserer splidsninger, konnektore, fejl samt enden på fiberenMåler tab på splidsninger, konnektore og fejlMåler refleksioner på fejl og konnektoreMåler total optisk returtab (ORL)

Rundt om E6000C

Rundt om E6000C

• Start/stop af laser

• Cursor

• Vælg

• Hjælp

When You Turn the Mini-OTDR On

OTDR assistance

Solution Inter-compatibility and Software

8147 OTDR

E6000C Mini-OTDR

MODIFY/ENTERZOOM

10

E6090A / E6091AToolkit / Toolkit II

OTDR PCsoftware

MODIFY/ENTERZOOM

10

Bellcore Standard Trace Format

Test og certificering af kabelsystemer, workshop

MålgruppeKurset henvender sig til teknikere, der skal måle og fejlfinde på kabel-systemer med Fluke DSP4x00 og DTX kabeltester.

ForudsætningerErfaring med kabelsystemer, og gerne erfaring med DSP-100 eller tilsvarende kabeltestere.

Hovedemner• Gennemgang af de nyeste standarder Cat. 5/Class D og Cat. 6/Class E og

fiberstandarder• Gennemgang af måleparametre som PSNEXT, PSELFEXT, Delay Skew m.fl.• Test af fiberinstallationer. • Beregning af powerbudget m.m.• Workshop• Test/fejlfinding på Cat. 5 og Cat 6 installationer

KursusbeskrivelseKurset er opbygget som en blanding af teori og praktiske øvelser med DSP-4x00 kabeltester. De praktiske øvelser er bygget op som en workshop, hvor deltagerne får lejlighed til at udføre en række relevante målinger på Cat. 5, Cat. 6 samt fiberinstallationer. Deltagerne får desuden lejlighed til at prøve at opgradere software på en DSP-4x00. Hvis man ønsker det, kan man medbringe sin egen DSP-4x00 og prøve at opgradere software på denne.

Max. antal kursister: 8

UdbytteEfter kurset er deltagerne godt rustet til at foretage målinger på nye kabelsystemer, og til at evaluere måleresultaterne. Deltagerne vil desuden få et kendskab til de nyeste standarder. En viden, som er essentiel når man arbejder med moderne kabelsystemer til højhastighedsnetværk.

KursusmaterialeKompendium med teori og øvelser

PrisKr. 1.500,- excl. moms.

Fiber splidse- og måleteknik OTDR kursusnr. 1 dag 9.00 – 16.00

MålgruppeKurset henvender sig til teknikere, der ønsker en grundlæggende teoretisk og praktisk viden om at splidsepå fiberkabler samt fejlfinde og måle på fiberinstallationer.

ForudsætningerDer kræves ingen specielle forudsætninger, men det vil være en fordel med et vist praktisk kendskab til fiber i forvejen.

Hovedemner Splidsning- Princip for fusionssplidsning- Krav til splidsninger- Fiberjustering og kernecentrering- Typer af fusionssplidsere- Processer i splidsningen- Fordele og ulemper- Komponent valg- Hands-on og praktiske øvelser

OTDR- Almindelige fejl- Hvor opstår fejlene?- Hvordan finder man fejlene?- Målenøjagtighed- Hvordan tolker man måleresultater?- Dokumentation- Måleinstrumenter- Hands-on og praktiske øvelser

UdbytteEfter kurset vil deltagerne være i stand til at udføre fusionssplidsninger såvel i marken (kabelbrønde) som i krydsfelter. Samt være i stand til at aflevere fyldestgørende dokumentation og udføre fejlfinding på fiberinstallationer.

Ovennævnte kursus kræves for at kunne leje Fusionssplidser og OTDR hos Solar A/S.

PrisKr. 1.500,- excl. moms.


Recommended