Page 1 of 3 936.5177/a Subject to alteration. 78211517, 78211518 Technical Data Type No. 78211517 Single unit 78211518 Double unit Pass band Band 1 [MHz] Band 2 [MHz] 1350 – 2200 2300 – 2690 Insertion loss Port 1 Port 3 [dB] Port 2 Port 3 [dB] < 0.2 (1350 – 2200) < 0.2 (2300 – 2690) Isolation Port 1 Port 2 [dB] > 50 VSWR < 1.25 Impedance [Ω] 50 Input power Band 1 / Band 2 [W] < 200 / < 200 Intermodulation products [dBc] < −160 (3 rd order; with 2 x 20 W) Temperature range [°C | °F] −40 ... +60 | −40 ... +140 Connectors 4.3-10 female (long neck) Application Indoor or outdoor (IP 66) DC/AISG transparency Port 1 Port 3 [mA] Port 2 Port 3 [mA] Auto-sense (max. 2000) Auto-sense (max. 2000) Lightning protection [kA] 3, 10/350 µs pulse Mounting [mm | in] Wall mounting: With 4 screws (max. 8 | 0.315 diameter) / Mast mounting: With included clamp set Weight [kg | lb] Single Unit: 3.5 | 7.7 / Double Unit: 6.9 | 15.2 Dimensions (w x h x d) [mm | in] Single Unit: 196.9 x 214.7 x 67.65 | 7.75 x 8.45 x 2.66 Double Unit: 196.9 x 214.7 x 138.65 | 7.75 x 8.45 x 5.45 (without connectors, without mounting brackets) Designed for co-sitting purposes Enables feeder sharing Integrated auto-sense technology for automatic DC/AISG detection and by-pass functionality Combine Mode (near BTS): DC/AISG auto-sense for port 1 to 3 and short circuit detection on port 4 Factory configurable behavior: First In - First Out Function (Factory default setting) Priority Controlled Function Exclusive User Function Split Mode (near antenna): Automatic DC/AISG by-pass from port 3 to port 1 … 2 if no short circuit is detected A detailed manual about auto-sense technology can be downloaded on our homepage. A short circuit detection is performed before allowing a DC/AISG signal to be passed from one of the ports 1 ... 2 to the common output (port 3) or vice versa. If a short circuit exists then a DC-Stop is activated on the corresponding RF-path. Suitable for indoor or outdoor applications Wall or mast mounting Available as a single unit, or for XPol antennas as a double unit Built-in lightning protection Port 1 Port 2 – 2690 MHz – 2200 MHz 1350 2300 Port 3 Dual-Band Combiner 1350 – 2200 MHz 2300 – 2690 MHz Port 1 Port 2 Port 3 Single Unit Double Unit clamps included AUTO- SENSE Kathrein USA Greenway Plaza II, 2400 Lakeside Blvd., Suite 650, Richardson TX 75082 Phone: 214.238.8800 Fax: 214.238.8801 Email: [email protected] All specifications are subject to change without notice. The latest specifications are available at www.kathreinusa.com
Transcript
Page 1: Dual-Band Combiner - Kathrein USA936.5177a Subject to alteration. Dimensions 78211517, 78211518 Page 3 of 3 Dual-Band Combiner 1350 – 2200 MHz 2300 – 2690 MHz Kathrein USA Greenway

Page 1 of 3

936.

5177

/aS

ubje

ct t

o al

tera

tion.

78211517, 78211518

Technical Data

Type No. 78211517Single unit

78211518Double unit

Pass band Band 1 [MHz] Band 2 [MHz]

1350 – 22002300 – 2690

Insertion loss Port 1 ↔ Port 3 [dB] Port 2 ↔ Port 3 [dB]

< 0.2 (1350 – 2200)< 0.2 (2300 – 2690)

Isolation Port 1 ↔ Port 2 [dB] > 50

VSWR < 1.25

Impedance [Ω] 50

Input power Band 1 / Band 2 [W] < 200 / < 200

Intermodulation products [dBc] < −160 (3rd order; with 2 x 20 W)

Temperature range [°C | °F] −40 ... +60 | −40 ... +140

Connectors 4.3-10 female (long neck)

Application Indoor or outdoor (IP 66)

DC/AISG transparency Port 1 ↔ Port 3 [mA] Port 2 ↔ Port 3 [mA]

Auto-sense (max. 2000)Auto-sense (max. 2000)

Lightning protection [kA] 3, 10/350 µs pulse

Mounting [mm | in] Wall mounting: With 4 screws (max. 8 | 0.315 diameter) / Mast mounting: With included clamp set

Weight [kg | lb] Single Unit: 3.5 | 7.7 / Double Unit: 6.9 | 15.2

Dimensions (w x h x d) [mm | in] Single Unit: 196.9 x 214.7 x 67.65 | 7.75 x 8.45 x 2.66 Double Unit: 196.9 x 214.7 x 138.65 | 7.75 x 8.45 x 5.45

(without connectors, without mounting brackets)

• Designed for co-sitting purposes

• Enables feeder sharing

• Integrated auto-sense technology for automatic DC/AISG detection andby-pass functionality

Combine Mode (near BTS):

DC/AISG auto-sense for port 1 to 3 and short circuit detection on port 4Factory configurable behavior:First In - First Out Function (Factory default setting)Priority Controlled FunctionExclusive User Function

Split Mode (near antenna):

Automatic DC/AISG by-pass from port 3 to port 1 … 2 if no short circuitis detected

A detailed manual about auto-sense technology can be downloaded onour homepage.

• A short circuit detection is performed before allowing a DC/AISG signalto be passed from one of the ports 1 ... 2 to the common output (port 3)or vice versa. If a short circuit exists then a DC-Stop is activated on thecorresponding RF-path.

• Suitable for indoor or outdoor applications

• Wall or mast mounting

• Available as a single unit, or forXPol antennas as a double unit

• Built-in lightning protection

Port 1 Port 2– 2690 MHz– 2200 MHz1350 2300

Port 3

Dual-Band Combiner

1350 – 2200 MHz 2300 – 2690 MHz

Port 1

Port 2

Port 3

Single Unit

Double Unit

clamps

included

AUTO- SENSE

Kathrein USA Greenway Plaza II, 2400 Lakeside Blvd., Suite 650, Richardson TX 75082Phone: 214.238.8800 Fax: 214.238.8801 Email: [email protected]

All specifications are subject to change without notice.The latest specifications are available at www.kathreinusa.com

Page 2: Dual-Band Combiner - Kathrein USA936.5177a Subject to alteration. Dimensions 78211517, 78211518 Page 3 of 3 Dual-Band Combiner 1350 – 2200 MHz 2300 – 2690 MHz Kathrein USA Greenway

936.

5177

/a

Sub

ject

to

alte

ratio

n.

Page 2 of 3 78211517, 78211518

Dual-Band Combiner

1350 – 2200 MHz 2300 – 2690 MHz

Clamp Set

50-Ohm load

Type No. Clamp set suitable for mast diameter of

734365 [mm | in] 45 – 125 | 1.77 – 4.92

Type No. Description

78210484 50-Ohm load

Accessories (included)

Please Note:

The mounting plates can be removed by loosening the screws j to m (M5 x 12) and replaced with other means of mounting, always provided that the max. drilled depth of 7.5 mm is respected with the choice of replacement screws.

As a result of more stringent legal regulations and judgements regarding product liability, we are obliged to point out certain risks that may arise when products are used under extraordinary operating conditions.

Extraordinary operating conditions, such as heavy icing or exceptional dynamic stress (e.g. strain caused by oscillating support structures), may result in the breakage of a mast mounted device or even cause it to fall to the ground.

These facts must be considered during the site planning process.

The Triple-band Combiners are designed to operate under the environmental conditions as described in ETS 300 019-1-4 class 4.1 E and have passed environmental tests as recommended in ETS 300 019-2-4.

The installation team must be properly qualified and also be familiar with the relevant national safety regulations.

The details given in our data sheets have to be followed carefully when installing the combiners and accessories.

The limits for the coupling torque of RF connectors, recommended by the connector manufacturers must be obeyed.

Terminate unused inputs with a suitable 50-Ohm load, e.g. 78210484.

Any previous datasheet issues have now become invalid.

Accessories (order separately)

Typical Attenuation Curves

Diagram 1

-100

-90

-80

-70

-60

-50

-40

-30

-20

-10

0

1250 1400 1550 1700 1850 2000 2150 2300 2450 2600 2750 2900A

ttenu

atio

n / d

B

Frequency / MHz

Port 1↔Port 3 Port 2↔Port 3

1350 - 2200 2300 - 2690

Diagram 2

-1,00

-0,90

-0,80

-0,70

-0,60

-0,50

-0,40

-0,30

-0,20

-0,10

0,00

1250 1400 1550 1700 1850 2000 2150 2300 2450 2600 2750 2900

Atte

nuat

ion

/ dB

Frequency / MHz

Port 1↔Port 3 Port 2↔Port 3

1350 - 2200 2300 - 2690

In case DC/AISG signals are applied to two or more ports simultaneously then all DC/AISG signals will be blocked as shown in the logic table below:

Connectors Logic table

Port 1 0 1 0 1

Port 2 0 0 1 1

Port 3 0 1 1 0

First In - First Out Function (Factory Default Setting) If the First In – First Out function is set, then the first base station which supplies the combiner with DC voltage at any input port is bypassed to the common port. The DC from the second base station will be ignored.

Priority Controlled Function

If the Exclusive User function is set in the com-biner, then the first base station which supplies an appropriate DC voltage at any input port is bypassed to the common port. If a second DC/AISG signal is erroneously fed into the combiner, then none of the DC/AISG signals will be allowed to bypass to the common port.

Exclusive User Function

Kathrein USA Greenway Plaza II, 2400 Lakeside Blvd., Suite 650, Richardson TX 75082Phone: 214.238.8800 Fax: 214.238.8801 Email: [email protected]

All specifications are subject to change without notice.The latest specifications are available at www.kathreinusa.com

Page 3: Dual-Band Combiner - Kathrein USA936.5177a Subject to alteration. Dimensions 78211517, 78211518 Page 3 of 3 Dual-Band Combiner 1350 – 2200 MHz 2300 – 2690 MHz Kathrein USA Greenway

936.

5177

/aS

ubje

ct t

o al

tera

tion.

Dimensions

78211517, 78211518 Page 3 of 3

Dual-Band Combiner

1350 – 2200 MHz 2300 – 2690 MHz

Kathrein USA Greenway Plaza II, 2400 Lakeside Blvd., Suite 650, Richardson TX 75082Phone: 214.238.8800 Fax: 214.238.8801 Email: [email protected]

All specifications are subject to change without notice.The latest specifications are available at www.kathreinusa.com


Recommended