Powerful Quiet Beautiful
DUCTING PIECES
Q A S A I R R E S E R V E S T H E R I G H T T O C H A N G E S P E C I F I C AT I O N W I T H O U T N O T I C E ® I S A R E G I S T E R E D T R A D E M A R K M A D E I N R I N G W O O D 3 1 3 4
Qasair Rangehoods are Australia’s most reputable brand of rangehood.
Condari have specialised in manufacturing Qasair Rangehoods in Melbourne, Australia for over 40 years. Qasair has grown from a local operation to well-known brand that has offices around Australia and exports internationally to New Zealand and South-East Asia.
The premium quality, flexibility in design and exceptional effectiveness of the product sees that Qasair Rangehoods are a regular feature of premium homes and developments around Australia and beyond.
Being made locally, Qasair has the unique ability to manufacture custom designed rangehoods catering to almost any design requirement.
Qasair are committed to maintaining exceptional functionality whilst continuing to improve noise levels and maintaining its position at the forefront of design.
Qasair Rangehoods are proud to be the only wholly Australian owned and manufactured rangehood on the market.
Qasair Rangehoods are manufactured in Ringwood 3134.
Australian home cooks are among the most experimental in the world, they have the desire to cook diverse, complex, restaurant quality meals at home from a wide range of exotic cuisines. In recent years, the ‘Masterchef phenomenon’ has further advanced the way that families cook and has led to the trend of increasingly specialized and sophisticated cooking appliances available for the domestic market.
Qasair Rangehoods are serious about kitchen ventilation and are the only company that specialize in manufacturing rangehoods to suit Australian market conditions. Qasair Rangehoods understand the need for powerful and efficient kitchen ventilation that will do the job no matter which continent’s cuisine is on the menu tonight.
Working closely with the architectural industry, Qasair Rangehoods are not only powerful and quiet but beautiful as well and can be custom made to suit the customers’ requirements.
FOUNDATION FOR EXCELLENCE
DESIGNED FOR LIFE
1
Q A S A I R R E S E R V E S T H E R I G H T T O C H A N G E S P E C I F I C AT I O N W I T H O U T N O T I C E ® I S A R E G I S T E R E D T R A D E M A R K M A D E I N R I N G W O O D 3 1 3 4
AIR MOVEMENTQASAIR Rangehoods recommend a minimum of two motors with an air movement of 1800 cubic metres per hour over the following appliances:• indoor barbecues• deep fryers• wok burners > 15mj• fish burners• griddle plates• high speed gas grillers• teppanyaki plates• Asian & Indian cooking• cookware over 1000mm wide
METAL DUCTINGQASAIR recommend the use of rigid, metal, non-flammable ducting, and specify minimum dimensions for one, two or three motors. This duct size must not be reduced. QASAIR Rangehoods can be either top or back ducted.
GETTING IT RIGHT THE FIRST TIME
2
Q A S A I R R E S E R V E S T H E R I G H T T O C H A N G E S P E C I F I C AT I O N W I T H O U T N O T I C E ® I S A R E G I S T E R E D T R A D E M A R K M A D E I N R I N G W O O D 3 1 3 4
OUTSIDE ATMOSPHEREQASAIR Rangehoods recommend that all rangehoods be ducted to the outside atmosphere. Ducting into the ceiling space can cause leakage of smoke and odours into other parts of the house through joins and light fittings, and can also be a dangerous fire hazard.
PLAN AHEADWhere possible, ducting should be considered during the planning stage, or at least, frame stage. Every kitchen designer should consider the duct layout and the space required for duct work when designing a kitchen.
INSTALLATIONQASAIR Rangehoods are capable of extracting enormous quantities of air. A three motor QASAIR Rangehood has a maximum air movement of 2700 cubic metres of air per hour. Therefore, the effective design and dimensions of duct work is critical to the proper installation of the rangehood. The duct type or construction can significantly affect the performance of the rangehood. Bends, deflections and excessive length can also reduce the effectiveness of the rangehood by up to 70%. Other factors such as room size, height over the benchtop and the type of cooking appliances being used should also be considered when deciding on the rangehood and appropriate ducting.
TAKE THE RESPONSIBILITYIt is the responsibility of the client to inform the architect, kitchen designer, builder or cabinetmaker which QASAIR Rangehood they will be using, so that provisions for it can be made during construction.
It is also advised that the tradespeople on site are made aware of the special and specific requirements of QASAIR Rangehoods.
Always seek the recommendation and specifications of the manufacturer.
Q A S A I R R E S E R V E S T H E R I G H T T O C H A N G E S P E C I F I C AT I O N W I T H O U T N O T I C E ® I S A R E G I S T E R E D T R A D E M A R K M A D E I N R I N G W O O D 3 1 3 4
600 800
Qasair Rangehoods are designed to capture all by-products of cooking produced by every domestic cooking appliance available in Australia.
‘Standard’ benchtops have a depth of 600 mm. If the benchtop exceeds that depth, this will need to be considered in the specification of the rangehood. This is to ensure that the selected hood has a sufficient depth to perform correctly over the cooktop.
Similarly, a ‘standard’ overhead cabinet is 300 mm. If the joinery is going to exceed that depth, this will need to be considered in the specification of the rangehood.
If the cooking appliance has a width of 1000 mm or above, Qasair recommends a minimum of two motors in the rangehood.
If there is a barbecue, wok burner or teppanyaki plate in the cooking appliance, Qasair recommend a minimum of two motors in the rangehood.
1 Always use the correct sized ducting, or the air movement will be reduced.
2 Always use non-flammable ducting. In the case of fire, the duct will remain intact, unlike plastic ducting which will be burnt through.
3 Never use flexible or semi-rigid ducting, as the ridges on these ducts cause eddies along the sides, creating a disturbance which can reduce the airflow by up to 50%.
4 Always duct to the outside atmosphere in the shortest distance, and with as few bends as possible. A longer duct run will result in a reduction of the air movement.
5 Always have streamlined bends. Sharp 90 degree bends will reduce the airflow by up to 25%.
6 Never duct into the ceiling – this is a fire hazard.
General
Rulesof Installation
Q A S A I R R E S E R V E S T H E R I G H T T O C H A N G E S P E C I F I C AT I O N W I T H O U T N O T I C E ® I S A R E G I S T E R E D T R A D E M A R K M A D E I N R I N G W O O D 3 1 3 4
4
SING
LE M
OTO
Rt
112. VB-1/45 Vertical Bend Single Motor 45º
104. HB-1 Horizontal Bend Single Motor 90º
101. DL-1DL-1 CP
Single Motor Duct Length 1200mm
107. DD-1H R Duct Director Single Motor Horizontal Right
108. BD/WV-H-1BD/WV-H-1 SS
Back Draft Wall Vent Single Motor Horizontal
106. DD-1H LDuct Director Single Motor Horizontal Left
BDWVK-H-1
240I/I
110I/I
250
317 411
150
250
318I/I 75
157
110. BD/WV/K-H-1Back Draft Wall Vent & Cover Single Motor Horizontal
kit assembled as one piece
109. WVC-H-1WVC-H-1 SS
Wall Vent Cover Single Motor Horizontal
111. VB-1 Vertical Bend Single Motor 90º
105. HB-1/45 Horizontal Bend Single Motor 45º
103. DL-1 E Single Motor Duct Length Extension
102. DL-1 A Single Motor Duct Length 300mm
NOTE:
This Zinc Alume Strip is provided to join some duct pieces together. It will be clearly shown on the drawing of the piece it is supplied with.
SINGLE MOTOR DUCTINGI/I = Inside to Inside Measurement
SS = Stainless steel CP = Colourbond OR Powderkote
SS = Stainless Steel
Ducting with the SS code is made in stainless steel type 445M2 which has a chromium content of 22% which is far greater than marine grade stainless steel and provides better protection.
ROOF COWLS, WALL VENTS AND WALL VENT COVERS
Q A S A I R R E S E R V E S T H E R I G H T T O C H A N G E S P E C I F I C AT I O N W I T H O U T N O T I C E ® I S A R E G I S T E R E D T R A D E M A R K M A D E I N R I N G W O O D 3 1 3 4
5
SING
LE M
OTO
R
t
122. TR-1 Single Motor Transition DL-1 to 200ø
124. DR-200/45 200ø Bend 45º
125. DR-200/90 200ø Bend 90º
126. CH-200CH-200 CP
Chairman’s Hat 200ø
BD/SQ-RC 200
205
200
206
430
202
150
127. BD/SQ-RC 200BD/SQ-RC 200 CP
Back Draft Roof Cowl Single Motor 200ø
123. DR-200DR-200 CP
Duct Length 200ø
114. WVC-V-1WVC-V-1 SS
Wall Vent Cover Single Motor Vertical115. EV/DL-1
Eave Vent to Suit DL-1
BD/RC-1
110
I/I
340
150
240I/I
100
121 TT-1 Twisted Transition Single Motor
118. BD/RC-1BD/RC-1 SSBD/RC-1 CP
Back Draft Roof Cowl Single Motor
119. CD-920 Cavity Duct Extendible
120. CD-920 TO DL-1Cavity Duct to DL-1
117. WVC-6/7/9H-R/R Wall Vent Cover to Suit Rear Register Kit for 6/7/900H
116. BD-6/7/9-WV-R/R Back Draft Wall Vent Rear Register Kit to Suit
6/7/900H
113. BD/WV-V-1BD/WV-V-1 SS
Back Draft Wall Vent Single Motor Vertical
SS = Stainless steel CP = Colourbond OR Powderkote
Q A S A I R R E S E R V E S T H E R I G H T T O C H A N G E S P E C I F I C AT I O N W I T H O U T N O T I C E ® I S A R E G I S T E R E D T R A D E M A R K M A D E I N R I N G W O O D 3 1 3 4
8
SING
LE M
OTO
Rt
135. 6/7/900H-SC Spiggot Cap to Suit 6/7/900H
134. CF 6/7/900H Ceiling Flange to Suit 6/7/900H
132. DLE-DLE Flue Joiner Single Motor
133. DLE-S/S CAP Stainless Steel Flue Cap to Suit DLE
WVC-200
104
303
293I/I
195
129. WVC-200WVC-200 SS
Wall Vent cover to Suit Single Motor 200ø130. BD/D-1 (Previously BD/M-1)
Back Draft Damper Single Motor DL-1
BD/D-200
130
200
200
131. BD/D 200Back Draft Damper Single Motor 200ø
128. BD/WV-200Back Draft Wall Vent Single Motor 200ø
SS = Stainless steel CP = Colourbond OR Powderkote
Q A S A I R R E S E R V E S T H E R I G H T T O C H A N G E S P E C I F I C AT I O N W I T H O U T N O T I C E ® I S A R E G I S T E R E D T R A D E M A R K M A D E I N R I N G W O O D 3 1 3 4
9
TWIN
MO
TOR
212. VB-2/45 Vertical Bend Twin Motor 45º
BDWVK-H-2
652
250
150
75
400
250
653I/I
250
95240
I/I
110I/I
160
210. BD/WV/K-H-2Kit assembled as one piece. Two Single Motor. Back Draft Wall Vent Horizontal with telescopic length & cover
209. WVC-H-2WVC-H-2 SS
Wall Vent Cover Twin Motor Horizontal
203. DL-2DL-2 CP
Twin Motor Duct Length 1200mm
208. BD/WV-H-2BD/WV-H-2 SS
Back Draft Wall Vent Twin Motor Horizontal207. DD-2H-R
Duct Director Twin Motor Horizontal Right
206. DD-2H-L Duct Director Twin Motor Horizontal Left
205. HB-2/45 Horizontal Bend Twin Motor 45º
204. HB-2 Horizontal Bend Twin Motor 90º
TMT-OFFSET
275
575
145365
112240
240
202. TMT-L/R Twin Motor transition offset left or right to DL-2
201. TMT-2 (Previously TMT)Twin Motor Transition to DL-2
211. VB-2 Vertical Bend Twin Motor 90º
NOTE:
This Zinc Alume Strip is provided to join some duct pieces together. It will be clearly shown on the drawing of the piece it is supplied with.
TWIN MOTOR DUCTINGI/I = Inside to Inside Measurement
SS = Stainless steel CP = Colourbond OR Powderkote
SS = Stainless Steel
Ducting with the SS code is made in stainless steel type 445M2 which has a chromium content of 22% which is far greater than marine grade stainless steel and provides better protection.
ROOF COWLS, WALL VENTS AND WALL VENT COVERS
Q A S A I R R E S E R V E S T H E R I G H T T O C H A N G E S P E C I F I C AT I O N W I T H O U T N O T I C E ® I S A R E G I S T E R E D T R A D E M A R K M A D E I N R I N G W O O D 3 1 3 4
10
TWIN
MO
TOR
t
BD RC-2_04
224. DR-300DR-300 CP
Duct Length 300ø223. TMT-300
Twin Motor Transition to 300ø222. TR-2
Twin Motor Transition from DL-2 to 300ø
220 BD/RC-2BD/RC-2 SSBD/RC-2 CP
Back Draft Roof Cowl Twin Motor
221. TT-2 Twisted Transition Twin Motor
219. WVC-10/12H-R/R Wall Vent Cover to suit 10/1200H
225. DR-300/45 300ø Bend 45º
226. DR-300/90 300ø Bend 90º
227. CH-300CH-300 CP
Chairman’s Hat 300ø
218. BD-10/12-WV-R/R Back Draft Wall Vent 10/1200H
217. EV/DL-2 Eave Vent to Suit DL-2
216. WVC-V-2WVC-V-2 SS
Wall Vent Cover Twin Motor Vertical
215. BD/WV-V-2BD/WV-V-2 SS
Back Draft Wall Vent Twin Motor Vertical214. DD-2V-R
Duct Director Twin Motor Vertical Right213. DD-2V-L
Duct Director Twin Motor Vertical Left
SS = Stainless steel CP = Colourbond OR Powderkote
Q A S A I R R E S E R V E S T H E R I G H T T O C H A N G E S P E C I F I C AT I O N W I T H O U T N O T I C E ® I S A R E G I S T E R E D T R A D E M A R K M A D E I N R I N G W O O D 3 1 3 4
11
TWIN
MO
TOR
t
232. TR-DL-2/250SQ (Previously DL-2/250SQ) Twin Motor Transition DL-2 to 250SQ
233. TMT-250 Twin Motor Transition to 250SQ
TMT250_Left
245 245
275
575
240
240
30
30
234. TMT-250 LTwin Motor Transition to 250Sø offset left
236. DD-250 L (Previously TMT-250/90 L) Duct Deflector 250SQ Left
237. DD-250 R (Previously TMT-250/90 R )Duct Deflector 250SQ Right
235. TMT-250 RTwin Motor Transition to 250Sø offset right
239. HB-250 Horizontal Bend 250SQ 90º
240. HB-250/45 Horizontal Bend 250SQ 45º
238. DL-250DL-250 CP
Duct Length 250SQ
TR-250SQ/300
250I/I
250I/I
40250
60
298
WVC-300
128
403
393I/I
249
230. WVC-300WVC-300 SS
Wall vent cover to suit single motor 300ø229. BD/WV-300
Back Draft Wall Vent 300ø
231. TR-250/300 (Previously TMT-250/300) Twin Motor Transition 250Sø to 300ø
242. WVC-250 SQWVC-250 SQ SS
Wall Vent Cover 250SQ
241. BD/WV-250 SQBD/WV-250 SQ SS
Back Draft Wall Vent 250SQ
BD/SQ-RC 300
306305
150
300
530
302
150
228. BD/SQ-RC 300 BD/SQ-RC 300 CP
Back Draft Roof Cowl 300ø
SS = Stainless steel CP = Colourbond OR Powderkote
TMT250_Right
245 245
275
575240
240
30
30
Q A S A I R R E S E R V E S T H E R I G H T T O C H A N G E S P E C I F I C AT I O N W I T H O U T N O T I C E ® I S A R E G I S T E R E D T R A D E M A R K M A D E I N R I N G W O O D 3 1 3 4
12
TWIN
MO
TOR
t
BD/D-300
195
300
300
320
BD D-2
368
148
135
160
244. BD/D-2Back Draft Damper Twin Motor DL-2
245. BD/D 250SQ (Previously BD/M-250SQ)Back Draft Damper Twin Motor 250SQ
246. BD/D 300 Back Draft Damper Twin Motor 300ø
250. 10/12H-SC Spiggot Cap to Suit 10/1200H
248. DLE-2-S/S CAP Stainless Steel Flue Cap to Suit DLE-2
247. DLE-2 TO DLE-2 Flue Joiner Twin Motor
249. CF 10/1200H Ceiling Flange to Suit 10/1200H
253. CF 4F-1000-2 Ceiling Flange to Suit 4F 1000-2
254. CF 4F-1200-2 Ceiling Flange to suit 4F 1200-2
BDRC-250 SQ
250I/I
250I/I
254
100
450
243. BD/RC-250 SQBD/RC-250 SQ CP
Wall Vent Cover 250SQ
251. CF 3F-900-2 Ceiling Flange to Suit 3F 900-2
252. CF 3F-1200-2 Ceiling Flange tp suit 3F 1200-2
SS = Stainless steel CP = Colourbond OR Powderkote
Q A S A I R R E S E R V E S T H E R I G H T T O C H A N G E S P E C I F I C AT I O N W I T H O U T N O T I C E ® I S A R E G I S T E R E D T R A D E M A R K M A D E I N R I N G W O O D 3 1 3 4
13
TRIP
LE M
OTO
R
t
306. BD/WV-H-3BD/WV-H-3 SS
Back Draft Wall Vent Triple Motor Horizontal
DD-300SQ/DL-3
300
325
398
198
1315
848
305. DD-DL-3 (Previously WCV S3) Triple motor side duct outlet 300mm high
304. HB-3/45 Horizontal Bend Triple Motor 45º
BDWVK-H-3
987
250
150
7595
95
I/I240
I/I
110
400250
988I/I 160
302. DL-3DL-3 CP
Triple Motor Duct Length303. HB-3
Horizontal Bend Triple Motor 90º301. TMT-3 (Previously 3MT-DL-3)
Three Motor Transition to DL-3
307. WVC-H-3WVC-H-3 SS
Wall Vent Cover Triple Motor Horizontal
308. BD/WV/K-H-3Kit assembled as one piece. Three Single Motor Back Draft Wall Vent Horizontal with telescopic length & cover.
311. DD-3V-L Duct Director Triple Motor Vertical Left
310. VB-3/45 Vertical Bend Triple Motor 45º
312. DD-3V-R Duct Director Triple Motor Vertical Right
309. VB-3 Vertical Bend Triple Motor 90º
NOTE:
This Zinc Alume Strip is provided to join some duct pieces together. It will be clearly shown on the drawing of the piece it is supplied with.
TRIPLE MOTOR DUCTINGI/I = Inside to Inside Measurement
SS = Stainless steel CP = Colourbond OR Powderkote
SS = Stainless Steel
Ducting with the SS code is made in stainless steel type 445M2 which has a chromium content of 22% which is far greater than marine grade stainless steel and provides better protection.
ROOF COWLS, WALL VENTS AND WALL VENT COVERS
Q A S A I R R E S E R V E S T H E R I G H T T O C H A N G E S P E C I F I C AT I O N W I T H O U T N O T I C E ® I S A R E G I S T E R E D T R A D E M A R K M A D E I N R I N G W O O D 3 1 3 4
14
TRIP
LE M
OTO
Rt
BD/WV-350
440
440
350
55
200
324. BD/WV-350Back Draft Wall Vent Triple Motor 350ø
BD/SQ-RC-350
680
355
350
357
352
250
323. BD/SQ-RC 350BD/SQ-RC 350 CP
Back Draft Roof Cowl Triple Motor 350SQ
322. CH-350CH-350 CP
Chairmans Hat 350ø
320. DR-350/45 350ø Bend 45º
321. DR-350/90 350ø Bend 90º
319. DR-350DR-350 CP
Duct Length 350ø
325 WVC-350WVC-350 SS
Wall vent cover to suit single motor 350ø
3MT-350
348
112
910
I/I 240
240I/I
I/I 240
30490
317. TR-3 (Previously TMT-400x200/350) Triple Motor Transition DL-3 to 350ø
318. TMT-350 (Previously TR-3)Triple Motor Transition to 350ø
316. TT-3 Triple Motor Twisted Transition
313. BD/WV-V-3BD/WV-V-3 SS
Back Draft Wall Vent Triple Motor Vertical
314. WVC-V-3WVC-V-3 SS
Wall Vent Cover Triple Motor Vertical
315. BD/RC-3BD/RC-3 SSBD/RC-3 CP
Back Draft Roof Cowl Triple Motor
BD RC-3_03
TR-DL3/350
348
100
440
40
200
I/I400I/I
WVC-350
152
453
443I/I 288
SS = Stainless steel CP = Colourbond OR Powderkote
Q A S A I R R E S E R V E S T H E R I G H T T O C H A N G E S P E C I F I C AT I O N W I T H O U T N O T I C E ® I S A R E G I S T E R E D T R A D E M A R K M A D E I N R I N G W O O D 3 1 3 4
15
BCC 101. FRWV-H-1 SSWall Vent Horizontal.
Bushfire code compliant, up to and including BAL 29.
BCC 102. FRWV-V-1 SSWall Vent Vertical.
Bushfire code compliant, up to and including BAL 29.
BCC 103. FRC 200 SS200ø Roof Cowl .
Bushfire code compliant, up to and including BAL 29.
BCC 201. FRWV-H-2 SSWall Vent Twin Motor Horizontal.
Bushfire code compliant, up to and including BAL 29.
FRWVK-H-2
652
250
150
75
400
250
653I/I
250
95240
I/I
110I/I
160
BCC 203. FRWV-V-2 SSWall Vent Twin Motor Vertical.
Bushfire code compliant, up to and including BAL 29.
BCC 204. FRC 300 SSRoof Cowl 300ø.
Bushfire code compliant, up to and including BAL 29.
BCC 202. FRWV/K-H-2Kit assembled as one piece. Two Single Motor Back
Draft Wall Vent Horizontal with telescopic length & coverBushfire code compliant, up to and including BAL 29.
BCC 205. FRWV-250 SQ SSWall Vent Twin Motor 250SQ.
Bushfire code compliant, up to and including BAL 29.
Condari can also manufacture ducting that is compliant with AS3959:2009 up to and including BAL 29.
Examples of some of these ducting pieces are below, price is upon application.
SINGLE MOTOR BCC = Bushfire code compliant ducting
TWIN MOTOR BCC = Bushfire code compliant ducting
Q A S A I R R E S E R V E S T H E R I G H T T O C H A N G E S P E C I F I C AT I O N W I T H O U T N O T I C E ® I S A R E G I S T E R E D T R A D E M A R K M A D E I N R I N G W O O D 3 1 3 4
16
BCC 304. FRC 350 SS Fire Rated Roof Cowl 350ø.
Bushfire code compliant, up to and including BAL 29.
BCC 302. FRWV/K-H-3Kit assembled as one piece. Three Single Motor Back Draft Wall Vent Horizontal with telescopic length & cover
Bushfire code compliant, up to and including BAL 29.
BCC 303. FRWV-V-3 SSFire Rated Wall Vent Triple Motor Vertical.
Bushfire code compliant, up to and including BAL 29.
BCC 301. FRWV-H-3 SSFire Rated Wall Vent Triple Motor Horizontal.
Bushfire code compliant, up to and including BAL 29.
FRWV-K-H-3_01
987
250
150
7595
95
I/I240
I/I
110
400250
988I/I 160
BCC = Bushfire code compliant ductingTRIPLE MOTOR
Q A S A I R R E S E R V E S T H E R I G H T T O C H A N G E S P E C I F I C AT I O N W I T H O U T N O T I C E ® I S A R E G I S T E R E D T R A D E M A R K M A D E I N R I N G W O O D 3 1 3 4
17
INSTALLATIONI D E A S
Do it right the first time
1. FA 60L-1B
2. FA 90L-1T
3. FA 60L-1T
Q A S A I R R E S E R V E S T H E R I G H T T O C H A N G E S P E C I F I C AT I O N W I T H O U T N O T I C E ® I S A R E G I S T E R E D T R A D E M A R K M A D E I N R I N G W O O D 3 1 3 4
18
4. FA 60L-1T 5. FA 60L-1T
6. FA 60L-1T / FA 60L-1B 7. FA 90L-2T
8. FA 90L-2T 9. FA 90L-2T
Q A S A I R R E S E R V E S T H E R I G H T T O C H A N G E S P E C I F I C AT I O N W I T H O U T N O T I C E ® I S A R E G I S T E R E D T R A D E M A R K M A D E I N R I N G W O O D 3 1 3 4
19
FA 90L-2 B Rangehood
10. FA 90L-2B 11. FA 90L-2T
12. FA 90L-2T
CON 60L-1 T Rangehood
13. 600HL-T / 700HL-T / 900HL-T
14. 600HL-T
DL-1Duct length
DD-1 H-RDuct director horizontal right
BD/WV-H-1Wall vent horizontal
15. CON 60L-1T
Q A S A I R R E S E R V E S T H E R I G H T T O C H A N G E S P E C I F I C AT I O N W I T H O U T N O T I C E ® I S A R E G I S T E R E D T R A D E M A R K M A D E I N R I N G W O O D 3 1 3 4
20
16. CON 80L-1T 17. CON 60L-1T
LIS 800L-2 TRangehood
18. CON 80L-2T
LIS 1000L-2 TRangehood
19. 1200HL-2T
20. LIS 800L-2T 21. LIS1000L-2T
Q A S A I R R E S E R V E S T H E R I G H T T O C H A N G E S P E C I F I C AT I O N W I T H O U T N O T I C E ® I S A R E G I S T E R E D T R A D E M A R K M A D E I N R I N G W O O D 3 1 3 4
21
LIS 500L-1 TRangehood
LIS 800L-1 TRangehood
LIS 1000L-2 TRangehood
CON 80L-1 TRangehood
22. 3F 900L-2T / 1200HL-2T 23. LIS 500L-1T
24. LIS 800L-1T 25. CON 80L-1T / LIS 1000L-2T
26. LIS 1200L-2B
Q A S A I R R E S E R V E S T H E R I G H T T O C H A N G E S P E C I F I C AT I O N W I T H O U T N O T I C E ® I S A R E G I S T E R E D T R A D E M A R K M A D E I N R I N G W O O D 3 1 3 4
22
NOTES _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ __ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ __ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ __ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ __ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ __ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ __ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ __ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ __ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ __ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ __ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ __ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ __ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ __ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ __ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ __ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ __ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ __ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ __ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ __ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ __ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ __ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ __ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ __ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ __ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ __ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ __ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
Q A S A I R R E S E R V E S T H E R I G H T T O C H A N G E S P E C I F I C AT I O N W I T H O U T N O T I C E ® I S A R E G I S T E R E D T R A D E M A R K M A D E I N R I N G W O O D 3 1 3 4
23
NOTES _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ __ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ __ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ __ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ __ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ __ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ __ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ __ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ __ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ __ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ __ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ __ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ __ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ __ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ __ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ __ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ __ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ __ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ __ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ __ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ __ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ __ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ __ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ __ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ __ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ __ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ __ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
PR
INTE
D I
N A
US
TRA
LIA
10
/19
RANGEHOODS MADE IN RINGWOOD 3134
QASAIR ReSeRveS the RIght to chAnge SpecIfIcAtIon wIthout notIce. ® IS A RegISteRed tRAde MARk.
Manufactured in Australia by Condari Pty LtdT 1300 360 563www.qasair.com.au www.condari.com.au
Head office VICT 03 9482 7088 F 03 9482 7011 Email: [email protected]
NSW / ACTT 02 9316 4599 F 02 9316 9299 Email: [email protected]
QLDT 07 3423 3503 F 07 3282 9122 Email: [email protected]
SA / NTT 1300 360 563 F 03 9482 7011 Email: [email protected]
TAST 03 9482 7088 F 03 9482 7011 Email: [email protected]
WAT 08 9242 5387 F 08 9201 0887 Email: [email protected]
NEW ZEALAND – Kouzina AppliancesT +64 9 377 7822 F +64 9 377 7824 Email: [email protected] www.kouzina.co.nz
SINGAPORE – Eldric MarketingT +65 6339 1188 F +65 6743 0202 Email: [email protected]
www.condari.com.au