Modul 4 Fi R l ti St d d dC d Fire Regulation, Standards and Codes d i k3 www.duniak3.com No.1 Indonesia Portal for Occupational Health & Safety
Transcript
Page 1: DuniaK3.Fire.peraturandanStandard

Modul 4

Fi R l ti St d d d C dFire Regulation, Standards and Codes

d i k3www.duniak3.comNo.1 Indonesia Portal for Occupational Health & Safety

Page 2: DuniaK3.Fire.peraturandanStandard

Classification

• Perundangan/Regulation g g• Code

St d d• Standard• Recommended Practice

www.duniak3.comNo.1 Indonesia Portal for Occupational Health & Safety

Page 3: DuniaK3.Fire.peraturandanStandard

Perundangan Kebakaran Indonesia

• Khusus tentang kebakaran– Depnaker– Non Depnaker

• Departemen PU• Pemda (DKI dll)

• Dimuat dalam perundangan lain– UU Jasa Konstruksi– PP 11 tahun 1979 tentang Pemurnian dan

Pengolahan Migas– UU No 22 tahun 2004 tentang MIGAS– dll

www.duniak3.comNo.1 Indonesia Portal for Occupational Health & Safety

Page 4: DuniaK3.Fire.peraturandanStandard

Perundangan Kebakaran di Indonesia

• Undang-undang no 1 Tahun 1970 tentang Keselamatan Kerja• Permenaker 04/tahun 80 tentang syarat syarat pemasangan dan• Permenaker 04/tahun 80 tentang syarat-syarat pemasangan dan

pemeliharaan APAR• Permenaker 02/83 tentang Instalasi Alarm otomatik

• Kep. Menteri Tenaga Kerja No. Kep 187/MEN/1999 tentang Pengendalian Bahan Kimia Berbahaya

• Peraturan Menteri Tenaga Kerja No Per 02/Men/1981 Tentang bejana• Peraturan Menteri Tenaga Kerja No Per 02/Men/1981 Tentang bejana tekan

• Kep. Menteri Tenaga Kerja & Trans. No Kep 75/Men/2002 Tentang Pemberlakuan PUIL 2000

• Peraturan Khusus EE : Syarat K3 bahan mudah terbakar

P t Kh K S t K3 b h d h l d k• Peraturan Khusus K : Syarat K3 bahan mudah meledak

www.duniak3.comNo.1 Indonesia Portal for Occupational Health & Safety

Page 5: DuniaK3.Fire.peraturandanStandard

UU No.1 Tahun 1970 tentang Keselamatan Kerja

• Syarat keselamatan kerja (psl 3)y j (p )– Mencegah, mengurangi dan memadamkan

kebakarankebakaran– Mencegah dan mengurangi bahaya

peledakanpeledakan– Memberi kesempatan atau jalan

l tk di i d kt k b kmenyelamatkan diri pada waktu kebakaran atau kejadian-2 lain yang berbahaya

www.duniak3.comNo.1 Indonesia Portal for Occupational Health & Safety

Page 6: DuniaK3.Fire.peraturandanStandard

PP 11 tahun 1979 : Keselamatan kerja pada pemurnian dan pengolahan Migaspemurnian dan pengolahan Migas

• Pasal 3d – Semua bangunan dan instalasi yang didirikan didalam daerah yang mempunyaididirikan didalam daerah yang mempunyai kemungkinan besar timbulnya bahaya kebakaran harus dibuat dari bahan-bahan yang tidak mudah y gterbakar

• Pasal 34 – 35 Al t d k b k h hi t– Alat pemadam kebakaran harus memenuhi persyaratan

– Harus tersedia alat pemadam kebakaran yang baik setiap saat digunakan, termasuk instalasi air permanen

– Pada tempat-tempat tertentu harus disediakan alat pemadam kebakaran portabel

– Membentuk regu pemadam kebakaranMembentuk regu pemadam kebakaran– Memeriksa secara berkala semua peralatan pemadam

kebakaran

www.duniak3.comNo.1 Indonesia Portal for Occupational Health & Safety

Page 7: DuniaK3.Fire.peraturandanStandard

Kepmenaker 04/1980 Persyaratan APAR

• Jenis kebakaran dan media pemadamp• Pemasangan

P d– Penandaan– Penempatan

• Pemeliharaan– Pemeriksaan berkala– Pemeriksaan berkala– Percobaan berkala– Pengisian ulang

www.duniak3.comNo.1 Indonesia Portal for Occupational Health & Safety

Page 8: DuniaK3.Fire.peraturandanStandard

Kepmenaker 02/1983 Alarm Kebakaran

• Ketentuan Umum• Pemeliharaan dan Pengujian

Si ti D t k i• Sistim Deteksi panas• Sistim Deteksi asapp• Sistim Deteksi api (flame)

www.duniak3.comNo.1 Indonesia Portal for Occupational Health & Safety

Page 9: DuniaK3.Fire.peraturandanStandard

DEFINITION

CodeCode Systematic Collocation of Regulations and R l f P dRules of Procedure Contains Only mandatory Provisions Written in Form Generally Suitable for Adoption into Law

www.duniak3.comNo.1 Indonesia Portal for Occupational Health & Safety

Page 10: DuniaK3.Fire.peraturandanStandard

DEFINITION

Standard A Document Containing Criteria for Design, Construction, Installation,Inspection, Testing or Use of Equipment , Systems or Procedures y

Contain Mandatory Provisions Typically not written to Be adopted into Law May Be referenced by Codes or Other Regulation as aMay Be referenced by Codes or Other Regulation as a Minimum Performance Requirement

www.duniak3.comNo.1 Indonesia Portal for Occupational Health & Safety

Page 11: DuniaK3.Fire.peraturandanStandard

DEFINITION

Recommended PracticeRecommended PracticeA Non – mandatory Document Containing Industry Accepted Procedures or Methods for PerformingAccepted Procedures or Methods for Performing a Specific Task

www.duniak3.comNo.1 Indonesia Portal for Occupational Health & Safety

Page 12: DuniaK3.Fire.peraturandanStandard

UNDERSTANDING AND USING CODE & STANDARDS

Code & Standard – making OrganizationsBSN (B d St d i i N i l (I d i )BSN (Badan Standarisasi Nasional (Indonesia)National Fire Protection Association ( NFPA) American Petroleum Institute ( API )American Petroleum Institute ( API )American National Standards Institute ( ANSI )American Society for Testing of Materials ( ASTM )American Society of Mechanical Engineers ( ASME)Underwriter’s Laboratory ( UL )

www.duniak3.comNo.1 Indonesia Portal for Occupational Health & Safety

Page 13: DuniaK3.Fire.peraturandanStandard

BSN

• Banyak mengeluarkan standar y gmengenai kebakaran

• SNI mengenai kebakaran• SNI mengenai kebakaran

www.duniak3.comNo.1 Indonesia Portal for Occupational Health & Safety

Page 14: DuniaK3.Fire.peraturandanStandard

Keselamatan pada Bangunan Fasiltas Pelayanan Kesehatan

No : RSNI S-23-2004, Kategori : Rancangan SNI

Standar ini menetapkan kriteria untuk meminimalkan bahaya kebakaran, ledakan, dan kelistrikan pada bangunan fasilitas yang memberikan pelayanan kesehatan untuk manusia. Apendiks D mencakup prinsip perancangan dan penggunaan elektrikal dan peralatan elektronik yang membangkitkan arus berfrekuensi tinggi untuk pengobatan medik di rumah sakit, klinik, fasilitas ambulatori, dan klinik gigi, baik yang tetap atau bergerak (mobile). Standar ini memuat persyaratan minimum untuk kinerja, pemeliharaan, pengujian, dan tindakan yang aman untuk fasilitas, bahan, peralatan, dan peranti, termasuk bahaya lain yang terkait dengan bahaya prime.

10

Tata cara pengklasifikasian jenis penggunaan bangunan berdasarkan peringkat ancaman bahaya kebakaran

N RSNI T 11 2002 K t i R SNI.No : RSNI T-11-2002, Kategori : Rancangan SNI

Standar ini menjelaskan suatu cara untuk mengestimasi ancaman bahaya relatif terhadap keselamatan jiwa yang diakibatkan oleh kebakaran sesuai jenis penggunaan bangunan

11.

Tata Cara Perencanaan Akses Bangunan dan Akses Lingkungan Untuk Pencegahan Bahaya Kebakaran Pada Bangunan Rumah dan Gedung.

12.

Tata Cara Perencanaan Struktur Bangunan untuk Pencegahan Bahaya Kebaka-ran pada Bangunan Rumah dan Gedung

No : SNI 03-1736-1989, Kategori : S N I

Tata cara ini digunakan untuk perencanaan struktur bangunan terhadap pencegahan bahaya kebakaran pada bangunan rumah dan gedung

13.

Metode Pengujian Jalar Api Pada Permukaan Bahan Bangunan untuk Pencegahan Bahaya Kebakaran pada Rumah dan Gedung.

No : SNI 03-1739-1989, Kategori : S N I

Metode ini digunakan untuk menentukan mutu bahan bangunan dalam kelompok sukar terbakar (semi non-combustible), menahan api (fire retardant), agak menahan api (semi fire retardant) dan mudah terbakar (easilytible)

14.

Metode Pengujian Bakar Bahan Bangunan Untuk Pencegahan Bahaya Kebakaran Pada Bangunan Rumah dan Gedung

No : SNI 03-1740-1989, Kategori : S N I

Metode ini digunakan untuk menentukan sifat bahan bangunan yang tidak terbakar dan yang dapat terbakar pada bangunan rumah dan gedung

15.

Metode Pengujian Tahan Api Komponen Struktur Bangunan untuk Pencegahan Bahaya Kebakaran pada Bangunan Rumah dan Gedung

No : SNI 03-1741-1989, Kategori : S N I

Metode ini digunakan untuk menentukan klasifikasi ketahanan api dari komponen bangunan yang dinyatakan dalam satuan waktu 1/2 jam, 1 jam, 2 jam dan 3 jam

16

Tata Cara Pemasangan Sistem Hidran untuk Pencegahan Bahaya Kebakaran pada Bangunan Rumah dan Gedung.6.No : SNI 03-1745-1989, Kategori : S N I

Tata cara ini digunakan sebagai panduan dalam pemasangan sistem hidran untuk memberikan persyaratan minimum pada pemasangan sistem hidran dalam upaya pencegahan bahaya kebakaran pada bangunan rumah dan gedung

Page 15: DuniaK3.Fire.peraturandanStandard

Keselamatan pada Bangunan Fasiltas Pelayanan Kesehatan

No : RSNI S-23-2004, Kategori : Rancangan SNIStandar ini menetapkan kriteria untuk meminimalkan bahaya kebakaran, ledakan, dan kelistrikan pada bangunan fasilitas

yang memberikan pelayanan kesehatan untuk manusia. Apendiks D mencakup prinsip perancangan dan penggunaan elektrikal dan peralatan elektronik yang membangkitkan arus berfrekuensi tinggi untuk pengobatan medik di rumah sakit, klinik, fasilitas ambulatori, dan klinik gigi, baik yang tetap atau bergerak (mobile). Standar ini

t t i i t k ki j lih ji d ti d k t k f ilitmemuat persyaratan minimum untuk kinerja, pemeliharaan, pengujian, dan tindakan yang aman untuk fasilitas, bahan, peralatan, dan peranti, termasuk bahaya lain yang terkait dengan bahaya prime.

10

Tata cara pengklasifikasian jenis penggunaan bangunan berdasarkan peringkat ancaman bahaya kebakaran

.No : RSNI T-11-2002, Kategori : Rancangan SNIStandar ini menjelaskan suatu cara untuk mengestimasi ancaman bahaya relatif terhadap keselamatan jiwa yang

diakibatkan oleh kebakaran sesuai jenis penggunaan bangunan

11.

Tata Cara Perencanaan Akses Bangunan dan Akses Lingkungan Untuk Pencegahan Bahaya Kebakaran Pada Bangunan Rumah dan Gedung.

Tata Cara Perencanaan Struktur Bangunan untuk Pencegahan Bahaya Kebaka-ran pada Bangunan Rumah dan GedungBangunan Rumah dan Gedung

No : SNI 03-1736-1989, Kategori : S N I

12

Tata cara ini digunakan untuk perencanaan struktur bangunan terhadap pencegahan bahaya kebakaran pada bangunan rumah dan gedung2

.g g

Metode Pengujian Jalar Api Pada Permukaan Bahan Bangunan untuk Pencegahan Bahaya Kebakaran pada Rumah dan Gedung.

13.

Page 16: DuniaK3.Fire.peraturandanStandard

No : SNI 03-1746-2000, Kategori : S N I

Digunakan untuk pemasangan alat bantu evakuasi dalam upaya penyelamatan manusia dan meningkatkan keamanan terhadap bahaya kebakaran

18 Tata Cara Perencanaan Pemasangan Sistem-Deteksi Alarm untuk Pencegahan Bahaya Kebakaran pada Bangunan Rumah dan Gedung18. Tata Cara Perencanaan Pemasangan Sistem-Deteksi Alarm untuk Pencegahan Bahaya Kebakaran pada Bangunan Rumah dan Gedung

No : SNI 03-3985-1995, Kategori : S N I

Digunakan untuk memberikan persyaratan minimum pada pemasangan sistem deteksi dan alarm kebakaran sehingga bila terjadi kebakaran dapat diketahui secara cepat dan tepat

19. Instalasi Sprinkler Untuk Pencegahan Bahaya Kebakaran Pada Bangunan Rumah dan Gedung

No : SNI 03-3989-1995, Kategori : S N I

Digunakan untuk memberikan persyaratan minimum pada pemasangan springkler dalam upaya pencegahan bahaya kebakaran pada bangunan rumah dan gedung

20. Spesifikasi Hidran Kebakaran Tabung Basah

No : SNI 03-6382-2000, Kategori : S N INo : SNI 03 6382 2000, Kategori : S N I

Spesifikasi ini meliputi bermacam-macam tipe dan kelas hidran kebakaran tabung basah, untuk dipasang pada jaringan sistem pelayanan air minum di kawasan permukiman

21. Spesifikasi Sistem Pengolahan Udara di Dapur dan Ruang Parkir sebagai Pengendali Asap Kebakaran Dalam Bangunan

No : SNI 03-6420-2000, Kategori : S N I

Spesifikasi ini menjelaskan persyaratan-persyaratan untuk jenis-jenis sistem pengolahan udara

22. Instalasi Pompa yang Dipasang Tetap untuk Proteksi Kebakaran

No : SNI 03-6570-2001, Kategori : S N I

Standar ini berhubungan dengan pemilihan dan instalasi pompa yang memasok air untuk proteksi kebakaran pada bangunan gedung. Hal-hal yang dipertimbangkan termasuk : Pasokan air, pelepasan, dan peralatan pelengkap, Pasokan daya, penggerak elektrik dan kontrol, turbin uap penggerak dan kontrol, uji serah terima dan pengoperasian standar ini tidak mencakup kapasitas sistem pasokan air dan persyaratan tekanan (lihat A.2.1.1) maupun persyaratan yang mencakup pemeriksaan berkala, pengujian dan pemeliharaan sistem pompa kebakaran. Standar ini juga tidak mencakup persyaratan untuk instalasi pengkabulan unit pompa kebakaran.

23. Sistem Pengendalian Asap Kebakaran pada Bangunan Gedung

No : SNI 03-6571-2001, Kategori : S N INo : SNI 03 6571 2001, Kategori : S N I

" Standar ini ditujukan untuk keselamatan jiwa dan perlindungan harta benda terhadap bahaya kebakaran. " Standar ini digunakan untuk perancangan, instalasi, pengujian, pengoperasian dan pemeliharaan dari sistem pengolah udara mekanik baru atau perbaikan yang juga digunakan sebagai sistem pengendalian asap. " Standar ini menetapkan kriterial minimal untuk perancangan sistem pengendalian asap, sehingga memungkinkan penghuni menyelamatkan diri dengan aman dari dalam bangunan, atau bila dikehendaki ke dalam daerah aman di dalam bangunan; " Tujuan dari standar ini adalah sebagai pedoman dalam menerapkan sistem yang menggunakan perbedaan tekanan dan aliran udara untuk menyempurnakan satu atau lebih.

24. Spesifikasi Umum Sistem Ventilasi Mekanis dan Sistem Tata Udara sebagai Pengendali Asap Kebakaran Dalam Bangunan (Damper Kebakaran)

No : SNI 03-6767-2002, Kategori : S N I

Spesifikasi ini menjelaskan persyaratan umum yang berlaku untuk semua sistem pengolahan udara, termasuk sistem prakiraan tekanan udara tidak termasuk unit individual yang memiliki laju aliran udara kurang dari 1000 liter/detik dalam semua ruang tertutup

Page 17: DuniaK3.Fire.peraturandanStandard

No : SNI 03-6768-2002, Kategori : S N I

Spesifikasi ini menjelaskan sasran dari pengendalian asap dan persyaratan umum sistem pengolahan udara yang dapat digunakan untuk pengendalian asap.

26. Spesifikasi Sistem Pengola-han Udara Sentral Sebagai Pengendali Asap Kebakaran Dalam Bangunan

No : SNI 03-6769-2002, Kategori : S N I

Spesifikasi ini mencakup persyaratan mengenai sistem pengolahan udara sentral sebagai pengendali asap kebakaran dalam bangunan gedung dan dilakukan dengan dua cara yaitu : Pengendalian asap cara pembersihan dan Pengendalian asap terzona.

27. Spesifikasi Bahan Bangunan Untuk Pencegahan Bahaya Kebakaran Pada Bangunan Rumah dan Gedung

No : SNI 03-7565-2002, Kategori : S N I

Spesifikasi ini digunakan sebagai ketentuan teknis untuk pemilihan dan penggunaan bahan bangunan dalam upaya mengurangi resiko terhadap bahaya kebakaran, serta memperkecil resiko timbulnya kebakaran dan menyebarluasnya api

28. Metode Pengujian Proteksi Kebakaran Terhadap Pintu Kebakaran Pada Bangunan.

No : SNI 03-7566-2002, Kategori : S N I

Metode ini digunakan untuk melaksanakan pengujian proteksi kebakaran terhadap pintu kebakaran pada bangunan

29. Spesifikasi Damper Kebakaran

No : SNI 19-6718-2002, Kategori : S N I

Spesifikasi ini memuat persyaratan bahan, rancangan, pembuatan, kinerja pengujian dan penandaan damper kebakaran yang dapat berbentuk persegi atau bulat, sudu penutup tunggal atau ganda dan mempunyai cara kerja engsel atau buka tutup tirai

Page 18: DuniaK3.Fire.peraturandanStandard

AMERICAN SOCIETY OF TESTING AND MATERIALS

Voluntary Consensus Standard Development Organization St d d R l t t M t l Pl ti C t ti M t i lStandards Relate to Metals, Plastic, Construction Materials, Paints, Petroleum, and Other AreasPublishes More than 9,000 Standards in 68 Volumes ,

www.duniak3.comNo.1 Indonesia Portal for Occupational Health & Safety

Page 19: DuniaK3.Fire.peraturandanStandard

AMERICAN SOCIETY OF TESTING AND MATERIALAND MATERIAL

Commonly Referenced Test MethodsD 56 St d d M th dD – 56 Standard Methods

Point by Tang closed Tag Closed Cup Tester ( Open – cup Flash Point )

D – 86 Standard Method of Test For Distillation of Petroleum Products

D – 93 Standard Method of Test for FlashD 93 Standard Method of Test for Flash Point by the Pesky – Martins Closed Tester ( Closed- cup Flash Point )

D – 323 Standard Method of Test for Vapor Pressure ofD – 323 Standard Method of Test for Vapor Pressure of Pressure of Petroleum Products ( Reid Method )

www.duniak3.comNo.1 Indonesia Portal for Occupational Health & Safety

Page 20: DuniaK3.Fire.peraturandanStandard

AMERICAN SOCIETY OF TESTING AND MATERIALS

Commonly Referenced Test Methods ( Continued )D – 3278 Standard Methods for Flash Point of

Liquids by seta flash Closed Tester D – 3828 Standard Test Methods for Flash Point of

Liquids by Seta flash Closed TesterE - 119 Standard Test for fire resistance of

Materials E 1950 Fi T t f P t ti M t i l fE – 1950 Fire Tests of Protection Materials for

Structural Steel ( Also UL 1709 )

www.duniak3.comNo.1 Indonesia Portal for Occupational Health & Safety

Page 21: DuniaK3.Fire.peraturandanStandard

AMERICAN PETROLEUM INSTITUTE

Represent Member Companies G t l A iGovernmental Agencies The Public

Develop Industry StandardsDevelop Industry Standards

Enhance Industry Image

www.duniak3.comNo.1 Indonesia Portal for Occupational Health & Safety

Page 22: DuniaK3.Fire.peraturandanStandard

AMERICAN NATIONAL STANDARDS INSTITUTE

Identifies Need for National Consensus Standards E D l t f St d dEncourages Development of Standards

Verifies Consensus

www.duniak3.comNo.1 Indonesia Portal for Occupational Health & Safety

Page 23: DuniaK3.Fire.peraturandanStandard

AMERICAN SOCIETY OF MECHANICAL ENGINEERS

Engineering Society Representing Mechanical Engineering DisciplineDiscipline Develops Rules for the Construction and testing of :

Steam Boilers

Pressure Vessels

www.duniak3.comNo.1 Indonesia Portal for Occupational Health & Safety

Page 24: DuniaK3.Fire.peraturandanStandard

UNDERWRITERS LABORATORIES AND FACTORY

MUTUAL ENGINEERINGMUTUAL ENGINEERING

Independent Testing OrganizationsInsurance Orientation Develop Test Methods for EquipmentDevelop Test Methods for Equipment Publish Lists of Equipment that Pass Applicable TestsApplicable Tests

www.duniak3.comNo.1 Indonesia Portal for Occupational Health & Safety

Page 25: DuniaK3.Fire.peraturandanStandard

APIA i P t lAmerican Petroleum Institutest tute

www.duniak3.comNo.1 Indonesia Portal for Occupational Health & Safety

Page 26: DuniaK3.Fire.peraturandanStandard

API STANDARDS AND RECOMMENDED

PRACTICESPRACTICES

RP 500 Classification of locations for Electrical InstallationsRP 520 P li i D i i R fi iRP 520 Pressure – relieving Devices in Refineries RP 521 Pressure – relieving and Depress ring SystemsRP 620 Low – Pressure Storage TanksRP 620 Low Pressure Storage TanksRP 650 Welded Steel Storage TanksRP 750 Management of Process Hazards RP 2000 Venting Atmospheric and Low – Pressure

Storage TanksSTD 2510 Liquefied Petroleum Gas InstallationsSTD 2510 Liquefied Petroleum Gas Installations

www.duniak3.comNo.1 Indonesia Portal for Occupational Health & Safety

Page 27: DuniaK3.Fire.peraturandanStandard

API PUBLICATIONS FOR FIRE PROTECTION AND

SAFETYSAFETY

RP 2001 Fire Protection in RefineriesRP 2003 Precaution Against Ignitions - Static lightning, and

Stray CurrentsPub 2009 Safe Welding and CuttingPub 2009 Safe Welding and Cutting Pub 2015 Cleaning Petroleum Storage TanksPub 2021 Fighting Fires in and around Petroleum Storage TanksPub 2026 Safe Descent onto floating RoofsPub 2201 Welding or Hot Tapping Pub 2218 Fireproofing PracticesPub 2218 Fireproofing Practices Pub 2510 A Fire Protection for LPG Storage facilities

www.duniak3.comNo.1 Indonesia Portal for Occupational Health & Safety

Page 28: DuniaK3.Fire.peraturandanStandard

REFINERY FIRE PROTECTION GUIDELINES

API RP 2001API RP 2001

Defines Basic Refinery Fire Protection W t S l Si iWater Supply Sizing

Amount of Water required Water Flow for Type of UnitWater Flow for Type of Unit Arrangement of Type of System Basic Requirements For Design

Water Systems and Equipment HydrantsHose ReelsHose Reels Fire MonitorsWater Sprays

www.duniak3.comNo.1 Indonesia Portal for Occupational Health & Safety

Page 29: DuniaK3.Fire.peraturandanStandard

REFINERY FIRE PROTECTION GUIDELINES API RP

2001 ( Continued )2001 ( Continued )

Fire ExtinguishersEmergency Response Organization Refinery Layout and Arrangement

Spacing Drainage

E I l ti Sh tdEmergency Isolation , Shutdown Protection of Critical Wiring, Controls C t l R P t tiControl Room Protection

www.duniak3.comNo.1 Indonesia Portal for Occupational Health & Safety

Page 30: DuniaK3.Fire.peraturandanStandard

REFINERY FIRE PROTECTION GUIDELINES API

STANDARD API 2510STANDARD API 2510

Defines Design, Construction, and Operational Consideration for LPG Facilities, Including : Tank Design Sitting Requirements and Spill Containment Tank Accessories and Relieving Devices Piping RequirementsUnloading,Loading and Product Transfer Fire Protection Refrigerated Storageg g

www.duniak3.comNo.1 Indonesia Portal for Occupational Health & Safety

Page 31: DuniaK3.Fire.peraturandanStandard

REFINERY FIRE PROTECTION GUIDELINES API STANDARD 2510 A

Contains Provisions for the Design, Operation and Maintenance of LPG Facilities to Prevent and Control Release and Firesof LPG Facilities to Prevent and Control Release and Fires Contents Include :Facility Design Philosophy y g p ySafe Operating Procedures Safe Maintenance Procedures Fire Control and Extinguishment Methods Technical Information

www.duniak3.comNo.1 Indonesia Portal for Occupational Health & Safety

Page 32: DuniaK3.Fire.peraturandanStandard

NFPA

• Not profit organizationp g• Publishing more than 270 fire codes

St d d d l b t h i l• Standard are develop by technical committees

www.duniak3.comNo.1 Indonesia Portal for Occupational Health & Safety

Page 33: DuniaK3.Fire.peraturandanStandard

NATIONAL FIRE PROTECTION ASSOCIATION

Promotes Safety from, Electricity, and Related Hazards

Services Include :Services Include :ResearchCodes Technical AdvicePublic Education

www.duniak3.comNo.1 Indonesia Portal for Occupational Health & Safety

Page 34: DuniaK3.Fire.peraturandanStandard

NFPA Publication

• NFPA 70 National Electrical Code• NFPA 11 Standard for Foam

Extinguishing SystemExtinguishing System• NFPA 15 Standard for Water Spray

Fixed System for Fire Protection• NFPA 10 Standard for Fire• NFPA 10 Standard for Fire

Extinguishers• NFPA 72 E Standard for Automatic Fire

Detection Systemywww.duniak3.com

No.1 Indonesia Portal for Occupational Health & Safety

Page 35: DuniaK3.Fire.peraturandanStandard

NFPA 70 NATIONAL ELECTRICAL CODE

Scope S l ti d I t ll ti f El t i l E i t I l diSelection and Installation of Electrical Equipment , Including Equipment in Hazardous Areas, As Determined by AP RP 500

www.duniak3.comNo.1 Indonesia Portal for Occupational Health & Safety

Page 36: DuniaK3.Fire.peraturandanStandard

NFPA 325M FIRE HAZARD PROPERTIES OF FLAMMABLELIQUIDS, GASES,

A Compilation of Basic Fire Protection Properties of Various Materials, Valuable for Determining :

Flash PointFlash Point Ignition Temperature Flammable Limits Specific Gravity and / or Vapor Density Boiling Point Suggested Extinguishing MethodsSuggested Extinguishing Methods

Of a Flammable Liquid or Gas or Volatile Solid

www.duniak3.comNo.1 Indonesia Portal for Occupational Health & Safety

Page 37: DuniaK3.Fire.peraturandanStandard

NFPA 10 PORTABLE FIRE EXTINGUISHERSPORTABLE FIRE EXTINGUISHERS

Selection Installation MaintenanceMaintenance Testing

www.duniak3.comNo.1 Indonesia Portal for Occupational Health & Safety

Page 38: DuniaK3.Fire.peraturandanStandard

NFPA 10 – PORTABLE FIRE EXTINGUISHERS

Class A Ordinary combustible materials such as wood,paper, plastic and rubber

Class B Flammable liquids,oil, greases paints and flammable gases

Class C Energized electrical equipments : when de – energized, fires generally become class A or B

Class D Combustible metals such as magnesium,titanium zirconium sodium, lithium and potassium

www.duniak3.comNo.1 Indonesia Portal for Occupational Health & Safety

Page 39: DuniaK3.Fire.peraturandanStandard

GUIDELINE FOR SELECTING PORTABLE FIRE EXTINGUISHERSLOCATION / SITUATION EXTINGUISHER TYPE

Class A ordinary Combustible Hazard Piped water not available or where t bl ti i h i l ll i d

21/2 gallon stored – pressure water or portable extinguisher is legally required

Lighter weight desired for ease of handling multi – purpose dry chemical extinguisher

Multipurpose dry chemical extinguisher

Class B Flammable liquids and Gases

Hazards

All outdoor hazards ( loading racks process plants ) Dry Chemical

Light indoor hazards ( e.g ) Laboratories, computer rooms reproduction / copy rooms )

Carbon DioxideHalon 1211 due recommended for new application isn't advisable for laboratories or kitchens due to the high discharge

velocity & risk of fire spread

Kitchens,cook tops,deep fat Multipurpose

Class C Energized Electrical Equipment Hazards

Heavy electrical machinery (motor,transformers,etc )

Carbon dioxide or dry chemical requires cleanup. Halon 1211 though effective is not recommended due to environmental concerns

www.duniak3.comNo.1 Indonesia Portal for Occupational Health & Safety

Page 40: DuniaK3.Fire.peraturandanStandard

NFPA 11 Low Expansion Foam Systemsp y

Scope : Covers Design Installation, and Testing of Foam Systems

Fixed Semi – Fixed Portable

www.duniak3.comNo.1 Indonesia Portal for Occupational Health & Safety

Page 41: DuniaK3.Fire.peraturandanStandard

NFPA 11 C

MOBILE FOAM APPARATUSMOBILE FOAM APPARATUS

ContentsG l R i tGeneral Requirements Proportioning System Requirements Acceptance Test RequirementsAcceptance Test Requirements

Foam System Test Water Pump Test Road Test

www.duniak3.comNo.1 Indonesia Portal for Occupational Health & Safety

Page 42: DuniaK3.Fire.peraturandanStandard

NFPA15 WATER SPRAY FIXED SYSTEMS

Contents General System Design ConsiderationsRequired clearances from live Electrical Equipment Requirements for System ComponentsRequirements for System Components System Water Supply Requirements System design and installation Requirements y g qAcceptance Test Procedures Periodic Testing and Maintenance Requirements System Documentation Requirements

www.duniak3.comNo.1 Indonesia Portal for Occupational Health & Safety

Page 43: DuniaK3.Fire.peraturandanStandard

NFPA 16 FOAM – WATER SPRINKLER AND FOAM – WATER SPRAY SYSTEMSSYSTEMS

For Open – head System Designed to Discharge either Fire Fighting Foam or Water Suitable for Installation in FlammableFighting Foam or Water, Suitable for Installation in Flammable Liquid Storage Areas and Loading Racks Contains requirements for the Design, Installation and Acceptance Testing of these SystemsContains Many of the Requirements Found in NFPA 15, plus Requirements for Components Involved With Foam ProductionRequirements for Components Involved With Foam Production

www.duniak3.comNo.1 Indonesia Portal for Occupational Health & Safety

Page 44: DuniaK3.Fire.peraturandanStandard

NFPA 20 INSTALLATION OF CENTRIFUGAL FIRE PUMPS

C t tContentsWater Supply RequirementsArrangement of Piping and FittingsArrangement of Piping and FittingsElectric Drives, Power Supplies, and ControlInternal Combustion Engine Drives and Control gSteam Turbine Drives and ControlAcceptance Test Procedures

Operation and Maintenance

www.duniak3.comNo.1 Indonesia Portal for Occupational Health & Safety

Page 45: DuniaK3.Fire.peraturandanStandard

NFPA 24 PRIVATE FIRE SERVICE MAINSPRIVATE FIRE SERVICE MAINS

Establishes Minimum Requirements for InstallationEstablishes Minimum Requirements for Installation of Private Fire Protection System and EquipmentContains Requirements for System Sectional Valves NumberContains Requirements for System Sectional Valves, Number and Location of Hydrants, Laying Pipe, and System Flushing

www.duniak3.comNo.1 Indonesia Portal for Occupational Health & Safety

Page 46: DuniaK3.Fire.peraturandanStandard

NFPA 30 FLAMMABLE AND COMBUSTIBLE LIQUIDS CODESQ

Applies to the Storage,Handling and Use of Flammable and pp g , gcombustible Liquids Refineries and Other Petroleum Facilities Excluded from Certain ProvisionsProvisions

www.duniak3.comNo.1 Indonesia Portal for Occupational Health & Safety

Page 47: DuniaK3.Fire.peraturandanStandard

NFPA 30 Topics Covered

Tank Storage : Design,Installation,Dikes,Overfill P t ti d Fi P t tiPresentation and Fire Protection Piping Systems: Materials, Joints, Supports Corrosion Protection Val es and TestingProtection , Valves and Testing Container Storage : Container Design and Size, Design and Size Design of Storage Areas ProtectionDesign and Size, Design of Storage Areas, Protection and Storage Lockers Plant operations : Design Liquid Handling TransferPlant operations : Design, Liquid Handling , Transfer and Use, Fire Prevention and Control

www.duniak3.comNo.1 Indonesia Portal for Occupational Health & Safety

Page 48: DuniaK3.Fire.peraturandanStandard

NFPA 30AAUTOMOTIVE AND MARINE SERVICE STATION

A li t A t ti d M i S i St tiApplies to Automotive and Marine Service Stations, Inside or Outside Includes Tank Storage Piping Dispensers VaporIncludes Tank Storage, Piping, Dispensers, Vapor Recovery System, electrical Equipment,and Operating RequirementsOperating Requirements

www.duniak3.comNo.1 Indonesia Portal for Occupational Health & Safety

Page 49: DuniaK3.Fire.peraturandanStandard

NFPA 58 STANDARD FOR STORAGE AND HANDLING OF LPG

SCOPE : Design ConstructionSCOPE : Design, Construction,Installation,of Playtex,TruckTransport

Application : Distribution Terminals,CylinderFilling and Storage, LPG AppliancesRetail and Private LPG Systems andRetail and Private LPG Systems andTransportation

www.duniak3.comNo.1 Indonesia Portal for Occupational Health & Safety

Page 50: DuniaK3.Fire.peraturandanStandard

NFPA 59A

PRODUCTION AND HANDLING OF LNGPRODUCTION, AND HANDLING OF LNG

Scope : Design, Location,Construction and Operating of Liquefaction Facilities and Storage, and Truck Transportation of LNG

Contents Include :Contents Include :Plant site ConsiderationsSpill and Leak ControlProcess Systems and EquipmentLNG Storage Container Design Design of Vaporization facilitiesDesign of Vaporization facilities Piping Systems Marine, Truck, and Tank Car Loading Fire Protection and Safety

www.duniak3.comNo.1 Indonesia Portal for Occupational Health & Safety