+ All Categories
Home > Documents > DWK pumps - api.grundfos.com

DWK pumps - api.grundfos.com

Date post: 20-Nov-2021
Category:
Upload: others
View: 4 times
Download: 0 times
Share this document with a friend
90
GRUNDFOS DATA BOOKLET DWK pumps 0.75 - 90 kW 60 Hz
Transcript
Page 1: DWK pumps - api.grundfos.com

GRUNDFOS DATA BOOKLET

DWK pumps0.75 - 90 kW60 Hz

Page 2: DWK pumps - api.grundfos.com

Ta

ble

of c

on

ten

ts

2

DWK pumps

1. Introduction 3Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3Applications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3Design features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3

2. Identification 5Nameplate . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5Type key . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5

3. Product selection 6Ordering a pump . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6

4. Performance range 7Performance ranges . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7

5. Product range 8

6. Variants 12List of variants . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12

7. Design 13Outlet connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13Exploded views and sectional drawings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14Material specification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38

8. Product description 40Features. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40Operating conditions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41Pump controllers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42Frequency converter operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42Wiring diagrams . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43

9. Curve charts and technical data 44How to read the curve charts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44Performance curve conditions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45Performance tests . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45Certificates . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45Witness test . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45

10. Performance curves and technical data 46DWK.O. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46DWK.E . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61DWK.H . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 73

11. Dimensions and weights 82DWK.O.6.50/80.xx.6 and DWK.O.10.80.37.6 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 82DWK.O.10.100.37.6 and DKW.O.13.xx.xx.6 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 83DWK.E . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 84DWK.H . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 85

12. Accessories 86

13. Grundfos Product Center 89

Page 3: DWK pumps - api.grundfos.com

Intr

od

uc

tio

n

DWK pumps 1

1. Introduction

IntroductionThis data booklet describes the Grundfos DWK dewatering pumps.

Fig. 1 DWK pump for free-standing installation

The pumps are designed with enclosed or semi-open impeller for use in a wide range of industrial and construction building sites.The pumps are made of resistant materials, such as cast iron and high-chrome stainless steel. These materials ensure proper operation.The pumps are fitted with 2-pole motors from 0.75 kW up to 90.0 kW.The free passage in the pumps is 10-20 mm. For DWK.H pumps, the free passage is 7 mm.The pumps are available for free standing, submerged installation.

ApplicationsThe pumps are ideal for transferring the following liquids:• drainage water• surface water• groundwater• water containing abrasives.DWK pumps are used in mining sites, building services, basement garages, construction sites, low lying rainwater catchment areas, processing industry.

Design featuresDWK pumps are designed with double mechanical shaft seals. The shaft seals are in the oil chamber. The pumps are only available with inlet strainer for free-standing installation. Optionally, the DWK.H can be ordered for auto-coupling installation.The pumps can be installed as single pump or be part of multi-pump installation.If required, the impeller diameter can be reduced to match a specific duty point.

Outlet connection

• Standard material versions have a DIN flange connection as standard.

• R high-grade material versions have hose coupling as standard.

Other outlet connections, or a version without outlet connection, are available on request. See section Variants on page 12.The following sections give further constructional details on the pump models DWK.O, DWK.E and DWK.H.

DWK.O• Watertight cable entry preventing water from

penetrating into the motor.• No extra cable is required for sensors.• Thermal protection through a PTO located in the coil

head, requires outside control through signal wires of the power cable, except for the following models:DWK.O.x.x.075.x.x.R DWK.O.x.x.15.x.x.R DWK.O.x.x.22.x.x.R DWK.O.x.x.37.x.0D.R.

• The above versions are equipped with a Klixon MV circuit breaker built in the motor compartment. It has an automatic reset and does not require outside control.

• Seal sensor for continuous monitoring of motor enclosure for liquid detection, except for the following models: DWK.O.x.x.075.x.xDWK.O.x.x.15.x.xDWK.O.x.x.22.x.xDWK.O.x.x.37.x.x.

• Top outlet for compact and narrow design.• Cooling jacket contributes to motor cooling by

keeping water level around the motor.• In R-versions, high-chrome stainless steel impeller

and spheroidal graphite iron inlet cover for increased wear resistance, if the pumped liquid contains abrasives. Stainless steel strainer for increased corrosion resistance.

• Double mechanical shaft seal (SiC-SiC) for heavy duty conditions.

• High-efficiency motor for high and stable performance and low operating costs.

TM06

917

4 24

15

3

Page 4: DWK pumps - api.grundfos.com

Intro

du

ctio

n

4

DWK pumps1

DWK.E• Triple cable entry system, including a rubber ring

and a rubber diaphragm. To ensure waterproof operation, the rubber diaphragm is filled with epoxy.

• No extra cable is required for sensors, except for the following models: DWK.E.x.x.75.x.x.xDWK.E.x.x.90.x.x.x.

• Thermal protection through a Klixon 17AM located in the coil head, requires outside control through signal wires of the power cable.

• Seal sensor for continuous monitoring of motor enclosure for liquid detection.

• Top outlet for compact and narrow design.• Cooling jacket contributes to motor cooling by

keeping water level at the top of the inlet strainer.• In R-versions, high-chrome stainless steel impeller

and spheroidal graphite iron inlet cover for increased wear resistance, if the pumped liquid contains abrasives. Stainless steel strainer for increased corrosion resistance.

• Triple sealing system consisting of a double mechanical shaft seal (SiC-SiC) in the oil chamber and an extra lip seal to withstand heavy-duty conditions.

• High-efficiency motor for high and stable performance and low operating costs.

DWK.H• Triple cable entry system, including a rubber ring

and a rubber diaphragm. To ensure waterproof operation, the rubber diaphragm is filled with epoxy.

• No extra cable is required for sensors, except for the following models:– DWK.H.x.x.750.x.x.x– DWK.H.x.x.900.x.x.x.

• Thermal protection through a Klixon 17AM located in the coil head, requires outside control through signal wires of the power cable.

• Seal sensor for continuous monitoring of motor enclosure for liquid detection.

• Cooling jacket contributes to motor cooling by keeping the water level at the top of the inlet strainer.

• Top outlet for compact and narrow design.• Two stage cast-iron impeller for high and stable

performance.• Double mechanical shaft seal (SiC-SiC) for heavy-

duty conditions.• High-efficiency motor for high and stable

performance and low operating costs.

Page 5: DWK pumps - api.grundfos.com

Ide

nti

fic

ati

on

DWK pumps 2

2. Identification

Nameplate

Fig. 2 DWK nameplate

Type keyNote: Pumps are not available in all variants.

DWKExample: DWK.O.6.50.075.6.0D.R

1 Exception: 075 = 0.75 kW2 Only for DWK.H range3 Pump with high-chrome stainless steel impeller and stainless steel

inlet strainer.4 For DWK pumps up to 30 kW

TM04

409

3 15

18Pos. Description

1 Notified body2 Type designation3 Product number and serial number4 Maximum head [m]5 Enclosure class6 Maximum installation depth [m]7 Number of phases8 Frequency [Hz]

9 Speed [min-1]

10 Weight [kg]11 Rated voltage [V], star connection12 Rated voltage [V], delta connection13 Insulation class14 Rated current [A], star connection15 Rated current [A], delta connection16 Motor input power P1 [kW]17 Motor output power P2 [kW]18 Power factor19 Maximum liquid temperature [°C]

20 Maximum flow [m3/h]

21 Production code [year/week]

123456789

10 11 12 13 14 15

1617

1819

20

21

DK-8850 Bjerringbro Denmark

TypeModelHmax Qmax Tmax. :

P.c.

m l/s c

9688

3812

Mad

e in

Chi

na

Motor ~ Hz P1/P2 kWn min-1

Weight kg AAV

V

Code Description Explanation

DWK Dewatering pump Pump typeO Semi-open impeller

Impeller typeE Enclosed impellerH High-head, double impeller6 Maximum solid size [mm] Strainer hole size

50 Nominal outlet diameter [mm] Pump outlet

121 Output power P2 / 1012 = 1.2 kW Power [kW]

[ ] StandardEquipment

S Sensor6 60 Hz Frequency [Hz]

0D 380-415 V, DOL

Voltage and starting method1D 380-415 V, Y/D0E 220-240 V, DOL1E 220-240 V, Y/D[ ] Standard

Pump version

A Auto coupling2

R Cast iron3

S Stainless steel1 Without outlet4

Z Custom-built variant Customisation

5

Page 6: DWK pumps - api.grundfos.com

Pro

du

ct s

ele

ctio

n

6

DWK pumps3

3. Product selection

Ordering a pumpPrior to ordering a pump, consider the following:• pump type• custom-built variant (option)• accessories• controller• outlet connection type

Note: DWK.H has a flanged outlet as standard.Once the pump type is selected, the most suitable pump can be identified. See section Product range on page 8 and Type key on page 5. The list below shows a detailed description of an ordered product:

• Pump as specified in the type key.• 10 m cable.• Paint: NCS S9000-N (black), gloss code 35,

thickness 100 μm.• Tested according to ISO 9906:2012, grade 3B.• As standard, DWK comes with a DIN flange outlet

connection. • As standard, DWK R version comes with a hose

outlet connection and Hi-Crome inlet strainer and impeller.

Note: Product specific data can be found in Grundfos Product Center at www.grundfos.com.For further details about Grundfos Product Center on page 89.

Custom-built variantsThe pumps can be customised to meet individual requirements. Several pump features and options are available for customisation, such as voltage, various cable lengths and special materials.For an overview, see section Variants on page 12. For requirements or designs not mentioned in the table, contact Grundfos.

AccessoriesDepending on the installation type, accessories may be required. See section Accessories on page 86, for selection of the correct accessories.Note: Accessories are not fitted.

Monitoring units and controllersThe following monitoring units and controllers are available:• GU01 (control system)• GU02 (control system)• LC 231 level controller with integrated motor

protection• LC 241 level controller a cabinet solution allowing

setup customisation.

Pump Product number

DWK.O.6.50.075.6.0E 96922680

Page 7: DWK pumps - api.grundfos.com

Pe

rfo

rma

nc

e r

an

ge

DWK pumps 4

4. Performance range

Performance ranges

Fig. 3 Performance range

TM04

295

0 42

190 10 20 30 40 50 60 70 80 90 100 110Q [l/s]

5

678

10

15

20

25

30

40

50

607080

100

150

H[m]

0 50 100 150 200 250 300 350 Q [m³/h]

DWK-O / DWK-E / DWK-H60 Hz

DWK-H

DWK-O DWK-E

DWK

Pump type Page

DW

K.O

DWK.O.6.50.075 46DWK.O.6.50.15 47DWK.O.6.50.22 48DWK.O.6.80.15 49DWK.O.6.80.22 50DWK.O.10.80.37 51DWK.O.13.80.55 52DWK.O.10.100.37 53DWK.O.13.100.55 54DWK.O.13.100.75 55DWK.O.13.100.110 56DWK.O.13.100.150 57DWK.O.13.150.75 58DWK.O.13.150.110 59DWK.O.13.150.150 60

DW

K.E

DWK.E.10.100.220 61DWK.E.10.150.220 62DWK.E.10.150.300 63DWK.E.10.150.370 64DWK.E.10.150.450 65DWK.E.10.150.550 66DWK.E.10.200.300 67DWK.E.10.200.370 68DWK.E.10.200.450 69DWK.E.10.200.550 70DWK.E.10.200.750 71DWK.E.10.200.900 72

DW

K.H

DWK.H.7.80.110 73DWK.H.7.80.150 74DWK.H.7.100.220 75DWK.H.7.100.300 76DWK.H.7.100.370 77DWK.H.7.150.450 78DWK.H.7.150.550 79DWK.H.7.150.750 80DWK.H.7.150.900 81

DWK

Pump type Page

7

Page 8: DWK pumps - api.grundfos.com

Pro

du

ct ra

ng

e

8

DWK pumps5

5. Product range

DWK.O

Pump type VoltageStarting method

Thermal protection Impeller type Outlet Product number

DWK.O.6.50.075.6.0D 3 × 380-415 V Y DOL PTO Semi-open DIN flange 96922679DWK.O.6.50.075.6.0E 3 × 220-240 V D DOL PTO Semi-open DIN flange 96922680DWK.O.6.50.075.6.0D.R 3 × 380-415 V Y DOL Klixon MW Semi-open Hose 96922759DWK.O.6.50.075.6.0E.R 3 × 220-240 V D DOL Klixon MW Semi-open Hose 96922760DWK.O.6.50.15.6.0D 3 × 380-415 V Y DOL PTO Semi-open DIN flange 96922681DWK.O.6.50.15.6.0E 3 × 220-240 V D DOL PTO Semi-open DIN flange 96922682DWK.O.6.50.15.6.0D.R 3 × 380-415 V Y DOL Klixon MW Semi-open Hose 96922761DWK.O.6.50.15.6.0E.R 3 × 220-240 V D DOL Klixon MW Semi-open Hose 96922762DWK.O.6.50.22.6.0D 3 × 380-415 V Y DOL PTO Semi-open DIN flange 96922685DWK.O.6.50.22.6.0E 3 × 220-240 V D DOL PTO Semi-open DIN flange 96922686DWK.O.6.50.22.6.0D.R 3 × 380-415 V Y DOL Klixon MW Semi-open Hose 96922765DWK.O.6.50.22.6.0E.R 3 × 220-240 V D DOL Klixon MW Semi-open Hose 96922766DWK.O.6.80.15.6.0D 3 × 380-415 V Y DOL PTO Semi-open DIN flange 96922683DWK.O.6.80.15.6.0E 3 × 220-240 V D DOL PTO Semi-open DIN flange 96922684DWK.O.6.80.15.6.0D.R 3 × 380-415 V Y DOL Klixon MW Semi-open Hose 96922763DWK.O.6.80.15.6.0E.R 3 × 220-240 V D DOL Klixon MW Semi-open Hose 96922764DWK.O.6.80.22.6.0D 3 × 380-415 V Y DOL PTO Semi-open DIN flange 96922687DWK.O.6.80.22.6.0E 3 × 220-240 V D DOL PTO Semi-open DIN flange 96922688DWK.O.6.80.22.6.0E.R 3 × 380-415 V Y DOL Klixon MW Semi-open Hose 96925932DWK.O.6.80.22.6.0D.R 3 × 220-240 V D DOL Klixon MW Semi-open Hose 96926023DWK.O.10.80.37.6.0D 3 × 380-415 V Y DOL PTO Semi-open DIN flange 96922689DWK.O.10.80.37.6.0E 3 × 220-240 V D DOL PTO Semi-open DIN flange 96922690DWK.O.10.80.37.6.0D.R 3 × 380-415 V Y DOL Klixon MW Semi-open Hose 96925933DWK.O.10.80.37.6.0E.R 3 × 220-240 V D DOL PTO Semi-open Hose 96925934DWK.O.10.100.37.6.0D 3 × 380-415 V Y DOL PTO Semi-open DIN flange 96922691DWK.O.10.100.37.6.0E 3 × 220-240 V D DOL PTO Semi-open DIN flange 96922692DWK.O.10.100.37.6.0D.R 3 × 380-415 V Y DOL Klixon MW Semi-open Hose 96925935DWK.O.10.100.37.6.0E.R 3 × 220-240 V D DOL PTO Semi-open Hose 96925936DWK.O.13.80.55.6.0D 3 × 380-415 V Y DOL PTO Semi-open DIN flange 96922693DWK.O.13.80.55.6.0E 3 × 220-240 V D DOL PTO Semi-open DIN flange 96922694DWK.O.13.80.55.6.0D.R 3 × 380-415 V Y DOL PTO Semi-open Hose 96925937DWK.O.13.80.55.6.0E.R 3 × 220-240 V D DOL PTO Semi-open Hose 96925938DWK.O.13.80.55.6.1D 3 × 380-415 V Y Y/D PTO Semi-open DIN flange 96926062DWK.O.13.80.55.6.1E 3 × 220-240 V D Y/D PTO Semi-open DIN flange 96926063DWK.O.13.80.55.6.1D.R 3 × 380-415 V Y Y/D PTO Semi-open Hose 96926094DWK.O.13.80.55.6.1E.R 3 × 220-240 V D Y/D PTO Semi-open Hose 96926095DWK.O.13.100.55.6.0D 3 × 380-415 V Y DOL PTO Semi-open DIN flange 96922695DWK.O.13.100.55.6.0E 3 × 220-240 V D DOL PTO Semi-open DIN flange 96922696DWK.O.13.100.55.6.0D.R 3 × 380-415 V Y DOL PTO Semi-open Hose 96925939DWK.O.13.100.55.6.0E.R 3 × 220-240 V D DOL PTO Semi-open Hose 96925940DWK.O.13.100.55.6.1D 3 × 380-415 V Y Y/D PTO Semi-open DIN flange 96926064DWK.O.13.100.55.6.1E 3 × 220-240 V D Y/D PTO Semi-open DIN flange 96926065DWK.O.13.100.55.6.1D.R 3 × 380-415 V Y Y/D PTO Semi-open Hose 96926096DWK.O.13.100.55.6.1E.R 3 × 220-240 V D Y/D PTO Semi-open Hose 96926097DWK.O.13.100.75.6.0D 3 × 380-415 V Y DOL PTO Semi-open DIN flange 96922697DWK.O.13.100.75.6.0E 3 × 220-240 V D DOL PTO Semi-open DIN flange 96922698DWK.O.13.100.75.6.0D.R 3 × 380-415 V Y DOL PTO Semi-open Hose 96925941DWK.O.13.100.75.6.0E.R 3 × 220-240 V D DOL PTO Semi-open Hose 96925942DWK.O.13.100.75.6.1D 3 × 380-415 V Y Y/D PTO Semi-open DIN flange 96926066DWK.O.13.100.75.6.1E 3 × 220-240 V D Y/D PTO Semi-open DIN flange 96926067DWK.O.13.100.75.6.1D.R 3 × 380-415 V Y Y/D PTO Semi-open Hose 96926098DWK.O.13.100.75.6.1E.R 3 × 220-240 V D Y/D PTO Semi-open Hose 96926099DWK.O.13.100.110.6.0D 3 × 380-415 V Y DOL PTO Semi-open DIN flange 96922701DWK.O.13.100.110.6.0E 3 × 220-240 V D DOL PTO Semi-open DIN flange 96922702DWK.O.13.100.110.6.0D.R 3 × 380-415 V Y DOL PTO Semi-open Hose 96925945DWK.O.13.100.110.6.0E.R 3 × 220-240 V D DOL PTO Semi-open Hose 96925946DWK.O.13.100.110.6.1D 3 × 380-415 V Y Y/D PTO Semi-open DIN flange 96926070DWK.O.13.100.110.6.1E 3 × 220-240 V D Y/D PTO Semi-open DIN flange 96926071DWK.O.13.100.110.6.1D.R 3 × 380-415 V Y Y/D PTO Semi-open Hose 96926102DWK.O.13.100.110.6.1E.R 3 × 220-240 V D Y/D PTO Semi-open Hose 96926103DWK.O.13.100.150.6.0D 3 × 380-415 V Y DOL PTO Semi-open DIN flange 96922705DWK.O.13.100.150.6.0D.R 3 × 220-240 V D DOL PTO Semi-open Hose 96925949DWK.O.13.100.150.6.0E 3 × 380-415 V Y DOL PTO Semi-open DIN flange 96925965DWK.O.13.100.150.6.0E.R 3 × 220-240 V D DOL PTO Semi-open Hose 96926002DWK.O.13.100.150.6.1D 3 × 380-415 V Y Y/D PTO Semi-open DIN flange 96926074

Page 9: DWK pumps - api.grundfos.com

Pro

du

ct

ran

ge

DWK pumps 5

DWK.O.13.100.150.6.1E 3 × 220-240 V D Y/D PTO Semi-open DIN flange 96926075DWK.O.13.100.150.6.1D.R 3 × 380-415 V Y Y/D PTO Semi-open Hose 96926106DWK.O.13.100.150.6.1E.R 3 × 220-240 V D Y/D PTO Semi-open Hose 96926107DWK.O.13.150.75.6.0D 3 × 380-415 V Y DOL PTO Semi-open DIN flange 96922699DWK.O.13.150.75.6.0E 3 × 220-240 V D DOL PTO Semi-open DIN flange 96922700DWK.O.13.150.75.6.0D.R 3 × 380-415 V Y DOL PTO Semi-open Hose 96925943DWK.O.13.150.75.6.0E.R 3 × 220-240 V D DOL PTO Semi-open Hose 96925944DWK.O.13.150.75.6.1D 3 × 380-415 V Y Y/D PTO Semi-open DIN flange 96926068DWK.O.13.150.75.6.1E 3 × 220-240 V D Y/D PTO Semi-open DIN flange 96926069DWK.O.13.150.75.6.1D.R 3 × 380-415 V Y Y/D PTO Semi-open Hose 96926100DWK.O.13.150.75.6.1E.R 3 × 220-240 V D Y/D PTO Semi-open Hose 96926101DWK.O.13.150.110.6.0D 3 × 380-415 V Y DOL PTO Semi-open DIN flange 96922703DWK.O.13.150.110.6.0E 3 × 220-240 V D DOL PTO Semi-open DIN flange 96922704DWK.O.13.150.110.6.0D.R 3 × 380-415 V Y DOL PTO Semi-open Hose 96925947DWK.O.13.150.110.6.0E.R 3 × 220-240 V D DOL PTO Semi-open Hose 96925948DWK.O.13.150.110.6.1D 3 × 380-415 V Y Y/D PTO Semi-open DIN flange 96926072DWK.O.13.150.110.6.1E 3 × 220-240 V D Y/D PTO Semi-open DIN flange 96926073DWK.O.13.150.110.6.1D.R 3 × 380-415 V Y Y/D PTO Semi-open Hose 96926104DWK.O.13.150.110.6.1E.R 3 × 220-240 V D Y/D PTO Semi-open Hose 96926105DWK.O.13.150.150.6.0D 3 × 380-415 V Y DOL PTO Semi-open DIN flange 96922706DWK.O.13.150.150.6.0D.R 3 × 220-240 V D DOL PTO Semi-open Hose 96925950DWK.O.13.150.150.6.0E 3 × 380-415 V Y DOL PTO Semi-open DIN flange 96925966DWK.O.13.150.150.6.0E.R 3 × 220-240 V D DOL PTO Semi-open Hose 96926003DWK.O.13.150.150.6.1D 3 × 380-415 V Y Y/D PTO Semi-open DIN flange 96926076DWK.O.13.150.150.6.1E 3 × 220-240 V D Y/D PTO Semi-open DIN flange 96926077DWK.O.13.150.150.6.1D.R 3 × 380-415 V Y Y/D PTO Semi-open Hose 96926108DWK.O.13.150.150.6.1E.R 3 × 220-240 V D Y/D PTO Semi-open Hose 96926109

Pump type VoltageStarting method

Thermal protection Impeller type Outlet Product number

9

Page 10: DWK pumps - api.grundfos.com

Pro

du

ct ra

ng

e

10

DWK pumps5

DWK.E

Pump type Voltage Starting method Thermal protection Impeller type Outlet Product number

DWK.E.10.100.220.6.1D 3 × 380-415 V D Y/D Klixon 17AM Enclosed DIN flange 96922707DWK.E.10.100.220.6.1D.R 3 × 380-415 V D Y/D Klixon 17AM Enclosed Hose 96925951DWK.E.10.100.220.6.1E 3 × 220-240 V D Y/D Klixon 17AM Enclosed DIN flange 96925978DWK.E.10.100.220.6.1E.R 3 × 220-240 V D Y/D Klixon 17AM Enclosed Hose 96926004DWK.E.10.150.220.6.1D 3 × 380-415 V D Y/D Klixon 17AM Enclosed DIN flange 96922708DWK.E.10.150.220.6.1D.R 3 × 380-415 V D Y/D Klixon 17AM Enclosed Hose 96925952DWK.E.10.150.220.6.1E 3 × 220-240 V D Y/D Klixon 17AM Enclosed DIN flange 96925979DWK.E.10.150.220.6.1E.R 3 × 220-240 V D Y/D Klixon 17AM Enclosed Hose 96926005DWK.E.10.150.300.6.1D 3 × 380-415 V D Y/D Klixon 17AM Enclosed DIN flange 96922709DWK.E.10.150.300.6.1D.R 3 × 380-415 V D Y/D Klixon 17AM Enclosed Hose 96925953DWK.E.10.150.300.6.1E 3 × 220-240 V D Y/D Klixon 17AM Enclosed DIN flange 96925980DWK.E.10.150.300.6.1E.R 3 × 220-240 V D Y/D Klixon 17AM Enclosed Hose 96926006DWK.E.10.150.370.6.1D 3 × 380-415 V D Y/D Klixon 17AM Enclosed DIN flange 96922711DWK.E.10.150.370.6.1D.R 3 × 380-415 V D Y/D Klixon 17AM Enclosed Hose 96925955DWK.E.10.150.370.6.1E 3 × 220-240 V D Y/D Klixon 17AM Enclosed DIN flange 96925982DWK.E.10.150.370.6.1E.R 3 × 220-240 V D Y/D Klixon 17AM Enclosed Hose 96926008DWK.E.10.150.450.6.1D 3 × 380-415 V D Y/D Klixon 17AM Enclosed DIN flange 96922713DWK.E.10.150.450.6.1D.R 3 × 380-415 V D Y/D Klixon 17AM Enclosed Hose 96925957DWK.E.10.150.450.6.1E 3 × 220-240 V D Y/D Klixon 17AM Enclosed DIN flange 96925984DWK.E.10.150.450.6.1E.R 3 × 220-240 V D Y/D Klixon 17AM Enclosed Hose 96926010DWK.E.10.150.550.6.1D 3 × 380-415 V D Y/D Klixon 17AM Enclosed DIN flange 96922715DWK.E.10.150.550.6.1D.R 3 × 380-415 V D Y/D Klixon 17AM Enclosed Hose 96925959DWK.E.10.150.550.6.1E 3 × 220-240 V D Y/D Klixon 17AM Enclosed DIN flange 96925986DWK.E.10.150.550.6.1E.R 3 × 220-240 V D Y/D Klixon 17AM Enclosed Hose 96926012DWK.E.10.200.300.6.1D 3 × 380-415 V D Y/D Klixon 17AM Enclosed DIN flange 96922710DWK.E.10.200.300.6.1D.R 3 × 380-415 V D Y/D Klixon 17AM Enclosed Hose 96925954DWK.E.10.200.300.6.1E 3 × 220-240 V D Y/D Klixon 17AM Enclosed DIN flange 96925981DWK.E.10.200.300.6.1E.R 3 × 220-240 V D Y/D Klixon 17AM Enclosed Hose 96926007DWK.E.10.200.370.6.1D 3 × 380-415 V D Y/D Klixon 17AM Enclosed DIN flange 96922712DWK.E.10.200.370.6.1D.R 3 × 380-415 V D Y/D Klixon 17AM Enclosed Hose 96925956DWK.E.10.200.370.6.1E 3 × 220-240 V D Y/D Klixon 17AM Enclosed DIN flange 96925983DWK.E.10.200.370.6.1E.R 3 × 220-240 V D Y/D Klixon 17AM Enclosed Hose 96926009DWK.E.10.200.450.6.1D 3 × 380-415 V D Y/D Klixon 17AM Enclosed DIN flange 96922714DWK.E.10.200.450.6.1D.R 3 × 380-415 V D Y/D Klixon 17AM Enclosed Hose 96925958DWK.E.10.200.450.6.1E 3 × 220-240 V D Y/D Klixon 17AM Enclosed DIN flange 96925985DWK.E.10.200.450.6.1E.R 3 × 220-240 V D Y/D Klixon 17AM Enclosed Hose 96926011DWK.E.10.200.550.6.1D 3 × 380-415 V D Y/D Klixon 17AM Enclosed DIN flange 96922716DWK.E.10.200.550.6.1D.R 3 × 380-415 V D Y/D Klixon 17AM Enclosed Hose 96925960DWK.E.10.200.550.6.1E 3 × 220-240 V D Y/D Klixon 17AM Enclosed DIN flange 96925987DWK.E.10.200.550.6.1E.R 3 × 220-240 V D Y/D Klixon 17AM Enclosed Hose 96926013DWK.E.10.200.750.6.1D 3 × 380-415 V D Y/D Klixon 17AM Enclosed DIN flange 96922717DWK.E.10.200.750.6.1D.R 3 × 380-415 V D Y/D Klixon 17AM Enclosed Hose 96925961DWK.E.10.200.750.6.1E 3 × 220-240 V D Y/D Klixon 17AM Enclosed DIN flange 96925988DWK.E.10.200.750.6.1E.R 3 × 220-240 V D Y/D Klixon 17AM Enclosed Hose 96926014DWK.E.10.200.900.6.1D 3 × 380-415 V D Y/D Klixon 17AM Enclosed DIN flange 96922718DWK.E.10.200.900.6.1D.R 3 × 380-415 V D Y/D Klixon 17AM Enclosed Hose 96925962

Page 11: DWK pumps - api.grundfos.com

Pro

du

ct

ran

ge

DWK pumps 5

DWK.H

Pump type Voltage Starting method Thermal protection Impeller type Outlet Product number

DWK.H.7.80.110.6.0D 3 × 380-415 V D DOL Klixon 17AM Enclosed - 2 stage DIN flange 99509676DWK.H.7.80.110.6.0E 3 × 220-240 V Y DOL Klixon 17AM Enclosed - 2 stage DIN flange 99509677DWK.H.7.80.150.6.0D 3 × 380-415 V D DOL Klixon 17AM Enclosed - 2 stage DIN flange 99509678DWK.H.7.80.150.6.0E 3 × 220-240 V Y DOL Klixon 17AM Enclosed - 2 stage DIN flange 99509679DWK.H.7.100.220.6.1D 3 × 380-415 V Y Y/D Klixon 17AM Enclosed - 2 stage DIN flange 99387168DWK.H.7.100.220.6.1E 3 × 220-240 V Y Y/D Klixon 17AM Enclosed - 2 stage DIN flange 99387169DWK.H.7.100.300.6.1D 3 × 380-415 V Y Y/D Klixon 17AM Enclosed - 2 stage DIN flange 99387170DWK.H.7.100.300.6.1E 3 × 220-240 V Y Y/D Klixon 17AM Enclosed - 2 stage DIN flange 99387171DWK.H.7.100.370.6.1D 3 × 380-415 V Y Y/D Klixon 17AM Enclosed - 2 stage DIN flange 99387172DWK.H.7.100.370.6.1E 3 × 220-240 V Y Y/D Klixon 17AM Enclosed - 2 stage DIN flange 99387173DWK.H.7.150.450.6.1D 3 × 380-415 V Y Y/D Klixon 17AM Enclosed - 2 stage DIN flange 99387174DWK.H.7.150.450.6.1E 3 × 220-240 V Y Y/D Klixon 17AM Enclosed - 2 stage DIN flange 99387175DWK.H.7.150.550.6.1D 3 × 380-415 V Y Y/D Klixon 17AM Enclosed - 2 stage DIN flange 99387176DWK.H.7.150.550.6.1E 3 × 220-240 V Y Y/D Klixon 17AM Enclosed - 2 stage DIN flange 99387177DWK.H.7.150.750.6.1D 3 × 380-415 V Y Y/D Klixon 17AM Enclosed - 2 stage DIN flange 99387178DWK.H.7.150.750.6.1E 3 × 220-240 V Y Y/D Klixon 17AM Enclosed - 2 stage DIN flange 99387179DWK.H.7.150.900.6.1D 3 × 380-415 V Y Y/D Klixon 17AM Enclosed - 2 stage DIN flange 99387180

11

Page 12: DWK pumps - api.grundfos.com

Va

rian

ts

12

DWK pumps6

6. Variants

List of variants

Note: Not all variants are available for all type of pumps

Note: DWK.H pumps are delivered with flange connection as standard. Auto coupling on request.

Motor

Various cable sizes Cable length depends on motor size and main supply.

10 m15 m20 m25 m30 m

Special motor (only for 19 and-22 kW)Insulation class H (180 °C)Temperature rise class B (80 °C)

Special voltage Contact Grundfos

Motor protection

Motor winding (only for 19 and 22 kW) 1 × Pt100 Contact GrundfosSeal sensor 1 × Electrode type Contact GrundfosBearing sensor (only for 19 and 22 kW) 1 × Pt100 in lower bearing Contact Grundfos

Material

Impeller Stainless steel 304, 316, 316L / Ductile cast iron A536-65-45-12 / Hi-Cr Contact GrundfosInlet cover and pump casing (only for 19 and 22 kW) Stainless steel 304, 316, 316L Contact Grundfos

Coating (only for 19 and 22 kW) According to EN 12944 IM2 Contact Grundfos

Outlet

FlangesDIN, JIS, ANSI Contact GrundfosKS, JIS, ANSI (DWK.H) Contact Grundfos

Hose Storz (DWK) Contact GrundfosThreaded Storz (DWK) Contact GrundfosNote: DWK.H pumps are delivered with flange connection as standard. Auto coupling on request.

Tests

Test at specified duty on standard impeller curveAdditional test of entire QH curve Contact GrundfosDifferent test standard ISO 9906:2012 grade 2B Contact GrundfosWitness test Contact Grundfos

Other variants Contact Grundfos

Page 13: DWK pumps - api.grundfos.com

De

sig

n

DWK pumps 7

7. Design

Outlet connectionsDWK pumps can be ordered with the following outlet connections:• flange connection• threaded outlet connection for Storz coupling,

according to ISO 228• hose connection• without outlet connection. Please order a discharge

connection separately.

Fig. 4 Outlet connections

TM04

473

537

1909

- TM

07 1

492

0219

Flange connectionHose connectionWithout connection Threaded connection

13

Page 14: DWK pumps - api.grundfos.com

De

sig

n

14

DWK pumps7

Exploded views and sectional drawings

DWK.O

Fig. 5 Exploded view DWK.O.6.50.075, DWK.O.6.50.15 and DWK.O.6.50.22

TM04

457

5 42

14

Page 15: DWK pumps - api.grundfos.com

De

sig

n

DWK pumps 7

Fig. 6 Sectional drawing DWK.O.6.50.075, DWK.O.6.50.15 and DWK.O.6.50.22

TM04

469

8 42

14

15

Page 16: DWK pumps - api.grundfos.com

De

sig

n

16

DWK pumps7

Fig. 7 Exploded view DWK.O.6.80.15, DWK.O.6.80.22, DWK.O.10.80.37 and DWK.O.10.100.37

TM04

470

8 18

18

181

181a

181b168

198

183183a

154a

154

193

194184

184a

178178a

198a

12

3535b

35a19019319476183b183c

151

37e

37b

172

9a

48

55

59

102

105c

105

39

46

49a

49

84c

84b

60a

60b

153

109

60182a

182

105b

39e

50

66188

189

188b188a

84a

Page 17: DWK pumps - api.grundfos.com

De

sig

n

DWK pumps 7

Fig. 8 Sectional drawing DWK.O.6.80.15 and DWK.O.6.80.22

TM04

469

9 42

14

17

Page 18: DWK pumps - api.grundfos.com

De

sig

n

18

DWK pumps7

Fig. 9 Sectional drawing DWK.O.10.80.37 and DWK.O.10.100.37

TM04

470

1 42

14

Page 19: DWK pumps - api.grundfos.com

De

sig

n

DWK pumps 7

Fig. 10 Exploded view DWK.O.13.80.55, DWK.O.13.100.55, DWK.O.13.100.75, DWK.O.13.150.75, DWK.O.13.100.110, DWK.O.13.150.110, DWK.O.13.100.150 and DWK.O.13.150.150

TM04

457

7 42

14

19

Page 20: DWK pumps - api.grundfos.com

De

sig

n

20

DWK pumps7

Fig. 11 Sectional drawing DWK.O.13.80.55 and DWK.O.13.100.55

TM04

470

0 42

14

Page 21: DWK pumps - api.grundfos.com

De

sig

n

DWK pumps 7

Fig. 12 Sectional drawing DWK.O.13.100.75 and DWK.O.150.75

TM04

470

2 42

14

21

Page 22: DWK pumps - api.grundfos.com

De

sig

n

22

DWK pumps7

Fig. 13 Sectional drawing DWK.O.13.100.110 and DWK.O.13.100.150

TM04

470

3 42

14

Page 23: DWK pumps - api.grundfos.com

De

sig

n

DWK pumps 7

Fig. 14 Sectional drawing DWK.O.13.150.110 and DWK.O.13.150.150

TM04

470

5 42

14

23

Page 24: DWK pumps - api.grundfos.com

De

sig

n

24

DWK pumps7

DWK.E

Fig. 15 Exploded view DWK.E.10.100.220, DWK.E.10.150.220, DWK.E.150.300 and DWK.E.10.200.300

TM04

457

6 18

18

13

3535b

183b

183c35a183

183a108

108a

151

37c

48

154

172

9a

59

109

109a

37b

181181a181b168198

168a

159

159a

184c

184b

184f

190d

55

60a

60b153a

153

102

184184a

182a182

155186a

186

39

50

107

189

55a

37a

60

193

194105b105c

105

39b

39a

46

150a

49a

49

66188

188b

188a

84a

84c

84b

Page 25: DWK pumps - api.grundfos.com

De

sig

n

DWK pumps 7

Fig. 16 Sectional drawing DWK.E.10.100.220

TM04

457

8 18

09

105c

25

Page 26: DWK pumps - api.grundfos.com

De

sig

n

26

DWK pumps7

Fig. 17 Sectional drawing DWK.E.10.150.220

TM04

458

0 18

09

105c

Page 27: DWK pumps - api.grundfos.com

De

sig

n

DWK pumps 7

Fig. 18 Sectional drawing DWK.E.10.150.300 and DWK.E.10.200.300

TM04

458

2 18

09

105c

27

Page 28: DWK pumps - api.grundfos.com

De

sig

n

28

DWK pumps7

Fig. 19 Exploded drawing DWK.E.10.150.370, DWK.E.10.150.450, DWK.E.10.200.370, DWK.E.10.200.450, DWK.E.10.150.550 and DWK.E.10.200.550

TM06

693

3 18

18

153a153

105c

1335

35b35a

183b183c

52252348a185

183183a108

108a

190d

151

37c

154a

48

154

172

109

109a

105b

46

150a3749a4966188

189188b188a

84a

84c84b

50

39186

186a155

39a

39b105

182182a19319460

184a18437a

55a

37b

102

5960b60a

55

9a

181181a181b168198

168a

159159a184c184b39c

Page 29: DWK pumps - api.grundfos.com

De

sig

n

DWK pumps 7

Fig. 20 Exploded drawing DWK.E.10.200.750 and DWK.E.10.200.900

TM04

470

7 18

18

153a

153

3535b

35a

183b

183c

183

183a108

108a

190d

37c

48

154

172

9a

59

109

109a

37b

13

181181a181b168198

168a

159159a

184c184b

184f

151

55

60a

60b

102

184184a

194193

182a182

186a

18639

50

107

55a

37a

60

105b105a

105

39b

39a

155

46

150a

49a

49

66188

189

188b188a

84a84c

84b

29

Page 30: DWK pumps - api.grundfos.com

De

sig

n

30

DWK pumps7

Fig. 21 Sectional drawing DWK.E.10.150.370, DWK.E.10.150.450, DWK.E.10.200.370 and DWK.E.10.200.450

TM04

458

4 18

09

105c

Page 31: DWK pumps - api.grundfos.com

De

sig

n

DWK pumps 7

Fig. 22 Sectional drawing DWK.E.10.150.550, DWK.E.10.200.550, DWK.E.10.200.750 and DWK.E.10.200.900

TM04

458

7 18

09

105c

31

Page 32: DWK pumps - api.grundfos.com

De

sig

n

32

DWK pumps7

DWK.H

Fig. 23 Exploded drawing DWK.H.7.100.110 and DWK.H.7.100.220

TM07

031

2 18

18

46

150a

155

105c105

84b84c

188a188b

26a26b

186186a

105b

39a

182182a

60

102

153153a

60b

60a

55a

109a

109

55

193

184184a

37a

59

37c

9a

172

154

48

151

37b

184b184c

159

159a

39c

198

190d

168a

181

168181b181a

183c183b

108a108183a183

35c

35b

35

12

194

39

39b 84a

189

107

18866

49

150b

50

26

49

46

117

3535b

13

Page 33: DWK pumps - api.grundfos.com

De

sig

n

DWK pumps 7

Fig. 24 Sectional drawing DWK.H.7.100.220 and DWK.H.7.100.150

TM07

031

7 48

17

188a

188b

107

26a

26b

26

39

186

186a

39a

193

37a

39b

109a

109

59

55a

55

37c

37b

184c

184b

39c

183c

183b

168a

159

198

168

181

181b

181a

84c

84b84a

188

189

66

49

50

9a

150b

117

49

184

184a

155

9a

60

150a

46

182

182a

105b

105c

105

102

60b

60a

48

172

151

35b

35c

35

154

12

153

153a

159a

33

Page 34: DWK pumps - api.grundfos.com

De

sig

n

34

DWK pumps7

Fig. 25 Sectional drawing DWK.H.7.100.370, DWK.H.7.150.450 and DWK.H.7.150.550

TM07

031

3 18

18

39b

186186a

48a

185

194

522523

182182a

60

102

153

60b60a

55a

109a

109

55

37a

153a

193

184184a

59

84a

189

107

188

66

49

50

26

49

117

150a

155

105c105

105b

84b84c

188a188b

26a26b

108a108183a183

35c

35b3512

46

150b

46

150c

35b35

37c

9a

172

154

48

151

37b

39c190d

183b183c

181a181b168

181

168a

198

159159a

184c184b

13

Page 35: DWK pumps - api.grundfos.com

De

sig

n

DWK pumps 7

Fig. 26 Sectional drawing DWK.H.7.100.370, DWK.H.7.150.450 and DWK.H.7.150.550

TM07

031

8 48

17

159

181

168

181b

181a

84c

84b

84a

189

188

49

50

66

9a

150c

117

49

9a

150b

182

182a

46

155

60

150a

105b

105c

105

102

60b

60a

48

172

151

154

35c

35b

35

12

190d

153

153a

159a

188a

188b

107

26

26b

26a

193

186

184

37a

184a

186a

39b

109a

109

59

55a

55

37c

184c

37b

184b

39c

183c

183b

168a

35

Page 36: DWK pumps - api.grundfos.com

De

sig

n

36

DWK pumps7

Fig. 27 Sectional drawing DWK.H.7.150.750 and DWK.H.7.150.900

TM0

7 03

14 4

817

46

150b

46

150c

182182a

60

102

153

60b60a

55a

109a

109

55

37a

153a

193

184184a

59

84a

189

107

18866

49

50

26

49

117

150a

105c105

105b

84b84c

188a188b

26a26b

108a108183a183

35c

35b3512

194

39b

186186a

13

35b35 155

37c

9a

172

154

48

151

37b

184b184c

159a

39c

198

190d

168a183c183b

159

181a181b168

181

Page 37: DWK pumps - api.grundfos.com

De

sig

n

DWK pumps 7

Fig. 28 Sectional drawing DWK.H.7.100.750 and DWK.H.7.100.900

TM07

031

9 48

17

188a

188b

107

26

26b

26a

193

186

184

37a

184a

186a

39b

109a

109

59

55a

55

37c

184c

37b

184b

39c

183c

183b

168a

159

181

168

181b

181a

84c

84b

84a

189

188

49

50

66

9a

150c

117

49

9a

150b

182

182a

46

155

60

150a

105b

105c

105

102

60b

60a

48

172

151

154

35c

35b

35

12

190d

153

153a

159a

37

Page 38: DWK pumps - api.grundfos.com

De

sig

n

38

DWK pumps7

Material specification

Pos. DescriptionMaterial

KS ASTM DIN

9a Key STS410 ANSI 410 17440

12 Flange1 GC200/GC250 A48-CL30/ A48-CL35 GG20/ GG25

13 Hose connection1 GC200/GC250 A48-CL30/ A48-CL35 GG20/ GG2526 O-ring NBR NBR NBR26a Washer STS304 A276-304 1.430126b Screw SM25C A108-1025 -35 Hexagon head cap screw STS304 A276-304 1.430135a O-Ring NBR NBR NBR35b Spring washer STS304 A276-304 1.430135c Gasket NBR NBR NBR37 O-ring NBR NBR NBR37a O-ring NBR NBR NBR37b O-ring NBR NBR NBR37c O-ring NBR NBR NBR37e Gasket NBR NBR NBR39 O-ring NBR NBR NBR39a O-ring NBR NBR NBR39b O-ring NBR NBR NBR39c O-ring NBR NBR NBR39e Gasket NBR NBR NBR46 Lip seal SCP1 SCP1 SCP146a Lip seal SCP1 SCP1 SCP148 Stator - - -

49 ImpellerStandard version GCD450 A536-77 GGG40R version Hi-Cr Hi-Cr Hi-Cr

49a Spacer ring SS400 A283-Gr.D -

50 Pump housing1 GC200/GC250 A48-CL30/ A48-CL35 GG20/ GG25

55 Motor housing1 GC200/GC250 A48-CL30/ A48-CL35 GG20/ GG2555a Outer casing (DWK.E/DWK.H) SPP A53-48 1629(1)-6159 Bearing cover1 GC200/GC250 A48-CL30/ A48-CL35 GG20/ GG25

60 Lower bearing bracket1 GC200/GC250 A48-CL30/ A48-CL35 GG20/ GG2560a Hexagon head cap screw SM25C A108-1025 -60b Spring washer SM25C A108-1025 -66 Spring washer STS304 A276-304 1.430176 Nameplate STS304 A276-304 1.4301

84a Inlet strainerStandard version SS400 A283-Gr.D -R version STS304 A276-304 1.4301

84b Hexagon head cap screw A276-304 1.430184c Spring washer STS304 A276-304 1.4301102 Stop ring STS304 A276-304 1.4301105 Mechanical shaft seal SIC/SIC SIC/SIC SIC/SIC105b Hexagon head cap screw SM25C A108-1025 -105c Shaft seal retainer STS304 A276-304 1.4301107 O-ring NBR NBR NBR108 Sealing Washer STS304 A276-304 1.4301108a O-ring NBR NBR NBR109 O-ring NBR NBR NBR109a O-ring NBR NBR NBR117 Bridge GC250 A48-CL35 GG25150 Shaft sleeve STS304 A276-304 1.4301150a Sleeve STS304 A276-304 1.4301150b Sleeve STS304 A276-304 1.4301150c Sleeve STS304 A276-304 1.4301

151 Motor bracket1 GC200/GC250 A48-CL30/ A48-CL35 GG20/ GG25153

Lower bearing --- --- ---153a154 Upper bearing - - -154a Cover - - -154c O-ring NBR NBR NBR

155 Shaft seal housing1 GC200/ GC250 A48-CL30/ A48-CL35 GG20/ GG25159 Rubber tube NBR NBR NBR

159a Clamping ring1 GC200/ GC250 A48-CL30/ A48-CL35 GG20/ GG25

168 Clamping ring1 GC200/ GC250 A48-CL30/ A48-CL35 GG20/ GG25

Page 39: DWK pumps - api.grundfos.com

De

sig

n

DWK pumps 7

1 Materials for products up to 15 kW / Materials for 19 kW and larger products; e.g.: GC200/ GC250

168a Cable entry1 GC200/ GC250 A48-CL30/ A48-CL35 GG20/ GG25172 Rotor with shaft STS410 ANSI410 -178 Hexagon head cap screw STS304 A276-304 1.4301178a Spring washer STS304 A276-304 1.4301181 Power supply cable PNTC 2RNCT 2RNCT181a Hexagon head cap screw STS304 A276-304 1.4301181b Spring washer STS304 A276-304 1.4301182 Hexagon head cap screw STS304 A276-304 1.4301182a Spring washer STS304 A276-304 1.4301183 Hexagon head cap screw STS304 A276-304 1.4301183a Spring washer STS304 A276-304 1.4301183b Hexagon head cap screw STS304 A276-304 1.4301183c Spring washer STS304 A276-304 1.4301184 Hexagon head cap screw STS304 A276-304 1.4301184a Spring washer STS304 A276-304 1.4301184b Hexagon head cap screw STS304 A276-304 1.4301184c Spring washer STS304 A276-304 1.4301184f O-ring NBR NBR NBR185 O-ring STS304 A276-304 1.4301186 Hexagon head cap screw STS304 A276-304 1.4301186a Spring washer STS304 A276-304 1.4301188 Hexagon nut STS304 A276-304 1.4301188a Hexagon head cap screw STS304 A276-304 1.4301188b Spring washer STS304 A276-304 1.4301189 Inlet cover GCD450 A536-77 GGG40190 Lifting bracket STS304 A276-304 1.4301190d Eyebolt SM30C A108-1030 -193 Oil plug STS304 A276-304 1.4301194 O-ring NBR NBR NBR198 Cable gland NBR NBR NBR198a Washer STS304 A276-304 1.4301522 Hexagon head cap screw STS304 A276-304 1.4301523 Spring washer STS304 A276-304 1.4301

Pos. DescriptionMaterial

KS ASTM DIN

39

Page 40: DWK pumps - api.grundfos.com

Pro

du

ct d

es

crip

tion

40

DWK pumps8

8. Product description

Features

Ball bearings

The top bearing is single row deep-groove ball bearing. The lower bearing, depending on the specific pump type can be:• one single row deep grove ball bearing. • two bearings, with 1 single row deep-groove ball

bearing and 1 single-row angular contact ball bearing.

All bearings are lubricated in the factory, no further lubrication is needed.

Shaft seals

DWK.O

The pumps have double mechanical shaft seals separating the motor from the pumped liquid. The shaft seals are in the oil chamber.The primary seal is SiC-SiC and the secondary is Carbon/Ceramic.

DWK.E, DWK.H

The pumps have double mechanical shaft seals and an additional lip seal. The additional lip seal protects the mechanical seals and shaft against abrasives. In case of wear, the lip seal can be replaced.Note: DWK.H 11 and 15 kW do not have any additional lip seal.The seal faces are made of SiC/SiC.

Motor

The motor is watertight and enclosed.Number of poles: 2Insulation class: F (155 °C).Temperature rise class: F (105 °C).Enclosure class IP68.

Motor range

Cables

The standard cable type is PNCT.

* 2EA - two power cableThe cables are 10 m long as standard. Other cable lengths are available on request. See section List of variants on page 12.The number and dimension of cables depend on the motor size.

Cable entry

DWK.O

Cable entry consists of rubber bushing. DWK.E, DWK.H

Cable entry consists of a rubber seal bushing, an epoxy diaphragm and a rubber cover. This provides radial and axial barrier against water penetration into the motor housing.

Pump type Power, P2 [kW]

DWK.O 0.75DWK.O 1.5DWK.O 2.2DWK.O 3.7DWK.O 5.5DWK.O 7.5

DWK.O/ DWK.H 11DWK.O/ DWK.H 15DWK.E/ DWK.H 22DWK.E/ DWK.H 30DWK.E/ DWK.H 37DWK.E/ DWK.H 45DWK.E/ DWK.H 55DWK.E/ DWK.H 75DWK.E/ DWK.H 90

Cable type Cable data

Pump type

Power (ground) cable

Sensor cable Outer cable

diameter [mm]

Bending radius

[mm2]Free[mm]

3 × 10 + 1 × 6 + 4 × 1 22 ± 1 330 DWK.H

3 × 16 + 1 × 10 + 4 × 1.5 26 ± 1 390 DWK.H

3 × 50 + 1 × 35* + 4 × 1.5 45.0 ± 1 675 DWK.E, DWK.H

4 × 1.5 - 13 ± 0.8 192 DWK.O

4 × 1.5 + 2 × 1 17.5 ± 0.5 263 DWK.O

4 × 2.5 + 4 × 1 21.5 ± 1 290 DWK.O

4 × 4 + 4 × 1 21.5 ± 1 323 DWK.O

4 × 6 + 4 × 1 25-25.4 ± 1 369 DWK.O

4 × 10 + 6 × 1 33.6 ± 1.0 354 DWK.O

6 × 10 + 1 × 6 + 6 × 1.5 34.0 ± 1 510 DWK.E, DWK.H

6 × 16 + 1 × 10 + 6 × 1.5 34.0 ± 1 510 DWK.E, DWK.H

6 × 25 + 1 × 16 + 6 × 1.5 42.0 ± 1 630 DWK.E, DWK.H

6 × 35 + 1 × 25 + 6 × 1.5 45.0 ± 1 675 DWK.E, DWK.H

7 × 4.0 + 4 × 1 25-25.4 ± 1 381 DWK.O

7 × 6.0 + 6 × 1 25-25.4 ± 1 429 DWK.O

Page 41: DWK pumps - api.grundfos.com

Pro

du

ct

de

sc

rip

tio

n

DWK pumps 8

Sensors

The following thermal protections are available for DWK pumps, depending on the specific pump type:

– PTO located in the coil head, requires outside control through signal wires of the power cable.

– Klixon MW built in the motor compartment. It has an automatic reset and does not require outside control.

– Klixon 17AM located in the coil head, requires outside control through signal wires of the power cable.

As standard, the pumps are fitted with a PTO that cuts the circuit, except for the following models:DWK.O.x.x.075.x.x.RDWK.O.x.x.15.x.x.RDWK.O.x.x.22.x.x.R andDWK.O.x.x.37.x.0D.R.These pumps have a Klixon MW circuit breaker instead of PTO.DWK pumps are equipped with seal sensor to monitor motor enclosure for liquid detection, except for the following models: DWK.O.x.x.075.x.xDWK.O.x.x.15.x.xDWK.O.x.x.22.x.xDWK.O.x.x.37.x.x.Customised sensor options1. Pt100 sensor monitors the motor temperature and

lower bearing in versions the sensor is not included as standard.

2. Seal electrode sensor monitors water penetration into the stator housing in which the sensor is not included as standard.

Testing

All pumps are tested before leaving the factory. The factory test report is based on ISO 9906:2012, grade 3B. Test reports can be ordered directly together with the pump or separately based on the pump serial number.Other tests or third-party inspection certificates are available on request. See section List of variants on page 12.

Operating conditionsThe pumps are designed for continuous (S1) and intermittent operation (S3).

Fig. 29 Liquid level for DWK.O pumps in S1 or S3 operation

For DWK.E and DWK.H, which have a cooling jacket, the minimum liquid level is above the pump housing.

Continuous operation

Continuous operation, S1, is allowed when the pump is completely submerged in the pumped liquid.

Fig. 30 Continuous operation

Intermittent operation

During intermittent operation, S3, the pump must run for maximum 4 minutes and stop for minimum 6 minutes.

Fig. 31 Intermittent operation

Maximum number of starts per hour

The maximum number of starts per hour for:• DWK.O is 30• DWK.E is 15• DWK.H is 15.

Pumped liquids

pH value: 4-10.Liquid temperature: 0-40 °C.When pumping liquids with a density and/or a kinematic viscosity higher than water, use motors with higher outputs.

TM04

414

4 07

09TM

02 7

775

4003

TM04

265

6 28

08

S1 operation

S3 operation

P

t

Stop

Operation

10 min

P

t

4 min 6 min

Operation

Stop

Maximum 4 minutes

Minimum 6 minutes

10 minutes

41

Page 42: DWK pumps - api.grundfos.com

Pro

du

ct d

es

crip

tion

42

DWK pumps8

Pump controllersThe pumps can be controlled by LC231 and LC 241 level controllers. Both controllers can be used in single or dual pump applications.The LC 231 is a compact solution with certified motor protection and current measurement. LC 231 can be operated in a single pump setup up to 12A or dual pump setup up to 9.6A. Starting method is only Direct On-Line for both analog pressure transmitter and digital float switches.The LC 241 is a cabinet solution allowing setup customisation. Basic settings are configured through the operating panel. Advanced settings are configured with Grundfos GO Remote through Bluetooth. LC 241 can be operated in single and dual pump setup to 72A.Starting methods are the following for both analog pressure transmitter and digital float switches:• Direct On-Line• Star Delta• Soft Starter.For further settings, see the installation and operating instructions for the selected level controller.

Frequency converter operationFrequency converter is available only for the DWK.E and DWK.H versions, for all sizes. DWK.O cannot be operated with frequency converter.Frequency converter operation exposes the motor insulation system to a heavier load and may cause the motor to be more noisy due to eddy currents caused by voltage peaks.In addition, large motors operated by a frequency converter are loaded by bearing currents.For more information, see the installation and operation instructions for the selected frequency converter in Grundfos Product Center at www.grundfos.com.

Page 43: DWK pumps - api.grundfos.com

Pro

du

ct

de

sc

rip

tio

n

DWK pumps 8

Wiring diagrams

Fig. 32 Wiring diagram, DOL-starting

Fig. 33 Wiring diagram, star-delta starting

TM04

409

6 07

09

Input power

Control panel

Control panel

PumpNote:1. T/P: Thermal switch2. S/S: Seal sensor

Auto Manual

Off

On

Reset

Note:F/L: Level controller

Start - stop Overload Run Stop Fault

Yellow Red Green

Off

TM04

409

7 07

09

L1 L2 L3

MCCB

V

A MCCB

MC Md My

THRGU 01 / GU 02

E

U1 V1 W1 W2 U2 V2

1.M3 ~

T / P T / P S / S S / S

S / S

F / L

MC

T

T My Md MC

AUX

THR THR

MC

OL RL GL AUX

6

5

GU

01/G

U02

6

8AUX

F / L

E1E2E3

GU

01/

GU

02

109321 T / P

S / S

T / P

S / S

11

O P . T R

Input power

Control panel

Control panel

PumpNote:1. T/P: Thermal switch2. S/S: Seal sensor

Auto Manual

Off

On

Reset

Note:F/L: Level controller

Start - stop Overload Run Stop Fault

Yellow Red Green

Off

43

Page 44: DWK pumps - api.grundfos.com

Cu

rve

ch

arts

an

d te

ch

nic

al d

ata

44

DWK pumps9

9. Curve charts and technical data

How to read the curve charts

Note: The pumps are tested according to ISO 9906:2012 grade 3B tolerance. Testing equipment and measuring instruments are designed and calibrated according to this standard. The pumps are approved according to tolerances for entire curves, specified in grade 3B.

TM07

660

6 22

20

� � � � � �� �� �� �� �� �� �� �� ��� ���

��

��

��

��

��

��

��

���

� � � � � � � � �� ��

��

��

��

��

��

�������

��������������

� �!!��"�����#

������

����

� � � � � �� �� �� �� �� �� �� �� ��� �����

���

���

���

���

���

$%��

�$�

�$�

Page 45: DWK pumps - api.grundfos.com

Cu

rve

ch

art

s a

nd

te

ch

nic

al

da

ta

DWK pumps 9

Performance curve conditionsThe guidelines below apply to the curves in chapter Performance curves and technical data on page 46. • Tolerances according to: ISO 9906:2012, grade 3B.• The curves indicate pump performance with

different impeller diameters at the rated speed.• The curves apply to the pumping of airless water at

a temperature of 20 °C and a kinematic viscosity of 1 mm2/s (1 cSt).

• The Eta curves show the efficiency of the pump. Eta 1 is the total efficiency (pump + motor). Eta 2 is the hydraulic efficiency of the pump.

• In case of other densities than 1000 kg/m3, the outlet pressure is proportional to the density.

• When pumping liquids with a density higher than 1000 kg/m3, motors with higher outputs must be used.

Calculation of total head

The total pump head can be calculated in the following way:

Performance testsThe requested duty point for every pump is tested according to ISO 9906:2012, grade 3B, and without certification.If pumps are ordered based on the impeller diameter (no requested duty point), they are tested at a duty point according to ISO 9906:2012, grade 3B.If more points on the curve are to be checked, individual measurements and certificates are available on request.

CertificatesCertificates are available on request and have to be confirmed for each order. For more information about different certificates, see List of variants on page 12.

Witness testIt is possible for the customer to witness the testing procedure according to ISO 9906:2012.The witness test is not a certificate and will not result in a written statement from Grundfos. The witness itself is the only guarantee that everything is carried out as prescribed in the testing procedure.If a witness test is required, it must be stated on the order.

Hgeo: Height difference between measuring points.Hstat: Differential head between inlet and the outlet

side of the pump.Hdyn: Calculated values based on the velocity of the

pumped liquid on the inlet and the outlet side of the pump.

Htotal Hgeo Hstat Hdyn+ +=

45

Page 46: DWK pumps - api.grundfos.com

Pe

rform

an

ce

cu

rve

s a

nd

tec

hn

ica

l da

ta

46

10

10. Performance curves and technical data

DWK.O

DWK.O.6.50.075.6

Electrical data

Pump data

TM04

293

3 21

16

Pump typeVoltage

[V]P2

[kW]RPM

Starting method

IN ηmotor [%] Cos φCable

[A] 1/2 3/4 1/1 1/2 3/4 1/1

DWK.O.6.50.075.6.0D 3 × 380-415 V Y 0.75 3450 DOL 1.5 72.5 77.5 79.2 0.72 0.82 0.88 4 × 1.5 mm2 + 2 × 1 mm2

DWK.O.6.50.075.6.0E 3 × 220-240 V D 0.75 3450 DOL 2.6 72.5 77.5 79.2 0.72 0.82 0.88 4 × 1.5 mm2 + 2 × 1 mm2

DWK.O.6.50.075.6.0D.R 3 × 380-415 V Y 0.75 3450 DOL 1.5 72.5 77.5 79.2 0.72 0.82 0.88 4 × 1.5 mm2

DWK.O.6.50.075.6.0E.R 3 × 220-240 V D 0.75 3450 DOL 2.6 72.5 77.5 79.2 0.72 0.82 0.88 4 × 1.5 mm2

Pump typeImpeller

type

Maximum solids size

[mm]

Maximum number of starts

per hour

Maximum installation depth [m]

Enclosure class

Insulation class

Maximum liquid temperature [°C]

pH

DWK.O.6.50.075.6 Semi-open 6 30 25 68 F 40 4-10

0 2 4 6 8 10 12 14 16 18 20 Q [m³/h]0

2

4

6

8

10

12

14

16

18

H[m]

0 1 2 3 4 5 6 Q [l/s]

0

10

20

30

40

50

60

70[%]Eta

DWK.O.6.50.075.660 Hz

ISO 9906 Annex AQH

Eta 2

Eta 1

0 2 4 6 8 10 12 14 16 18 20 Q [m³/h]0.0

0.2

0.4

0.6

0.8

1.0

P[kW]

QP1

QP2

Page 47: DWK pumps - api.grundfos.com

Pe

rfo

rma

nc

e c

urv

es

an

d t

ec

hn

ica

l d

ata

10

DWK.O.6.50.15.6

Electrical data

Pump data

TM04

293

4 09

16Pump type

Voltage[V]

P2 [kW]

RPMStarting method

IN ηmotor [%] Cos φCable

[A] 1/2 3/4 1/1 1/2 3/4 1/1

DWK.O.6.50.15.6.0D 3 × 380-415 V Y 1.5 3450 DOL 3.1 78.0 82.1 83.02 0.68 0.78 0.85 4 × 1.5 mm2 + 2 × 1 mm2

DWK.O.6.50.15.6.0E 3 × 220-240 V D 1.5 3450 DOL 5.3 78.0 82.1 83.02 0.68 0.78 0.85 4 × 1.5 mm2 + 2 × 1 mm2

DWK.O.6.50.15.6.0D.R 3 × 380-415 V Y 1.5 3450 DOL 3.1 78.0 82.1 83.02 0.68 0.78 0.85 4 × 1.5 mm2

DWK.O.6.50.15.6.0E.R 3 × 220-240 V Y 1.5 3450 DOL 5.3 78.0 82.1 83.02 0.68 0.78 0.85 4 × 1.5 mm2

Pump typeImpeller

type

Maximum solids size

[mm]

Maximum number of

starts per hour

Maximum installation depth

[m]

Enclosure class

Insulation class

Maximum liquid temperature [°C]

pH

DWK.O.6.50.15.6 Semi-open 6 30 25 68 F 40 4-10

� � � � � �� �� �� �� �� ��� ���

��

��

��

��

��

��

��

���

� � � � � � �� ��

��

��

��

��

��

��

�������

������������������&

� �!!��"�����#

��

����

����

� � � � � �� �� �� �� �� ��� ��������

���

���

���

���

���

���

$%��

�$�

�$�

47

Page 48: DWK pumps - api.grundfos.com

Pe

rform

an

ce

cu

rve

s a

nd

tec

hn

ica

l da

ta

48

10

DWK.O.6.50.22.6

Electrical data

Pump data

TM04

293

5 21

16Pump type

Voltage[V]

P2 [kW]

RPMStarting method

IN ηmotor [%] Cos φCable

[A] 1/2 3/4 1/1 1/2 3/4 1/1

DWK.O.6.50.22.6.0D 3 × 380-415 V Y 2.2 3450 DOL 4.1 79.8 83.1 86.1 0.71 0.82 0.89 4 × 1.5 mm2 + 2 × 1 mm2

DWK.O.6.50.22.6.0E 3 × 220-240 V D 2.2 3450 DOL 7.1 79.8 83.1 86.1 0.71 0.82 0.89 4 × 1.5 mm2 + 2 × 1 mm2

DWK.O.6.50.22.6.0D.R 3 × 380-415 V Y 2.2 3450 DOL 4.1 79.8 83.1 86.1 0.71 0.82 0.89 4 × 1.5 mm2

DWK.O.6.50.22.6.0E.R 3 × 220-240 V Y 2.2 3450 DOL 7.1 79.8 83.1 86.1 0.71 0.82 0.89 4 × 1.5 mm2

Pump typeImpeller

type

Maximum solids size

[mm]

Maximum number of starts

per hour

Maximum installation depth

[m]

Enclosure class

Insulation class

Maximum liquid temperature [°C]

pH

DWK.O.6.50.22.6 Semi-open 6 30 25 68 F 40 4-10

� � � � � �� �� �� �� �� �� �� �� ��� ���

��

��

��

��

���

� � � � � � � � �� ��

��

��

��

�������

������������������&

� �!!��"�����#

��

��������

� � � � � �� �� �� �� �� �� �� �� ��� �����

���

���

���

���

���

$%��

�$�

�$�

Page 49: DWK pumps - api.grundfos.com

Pe

rfo

rma

nc

e c

urv

es

an

d t

ec

hn

ica

l d

ata

10

DWK.O.6.80.15.6

Electrical data

Pump data

TM04

294

7 09

16Pump type

Voltage[V]

P2 [kW]

RPMStarting method

IN ηmotor [%] Cos φCable

[A] 1/2 3/4 1/1 1/2 3/4 1/1

DWK.O.6.80.15.6.0D 3 × 380-415 V Y 1.5 3450 DOL 3.1 78.0 82.1 83.02 0.68 0.78 0.85 4 × 1.5 mm2 + 2 × 1 mm2

DWK.O.6.80.15.6.0E 3 × 220-240 V D 1.5 3450 DOL 5.1 78.0 82.1 83.02 0.68 0.78 0.85 4 × 1.5 mm2 + 2 × 1 mm2

DWK.O.6.80.15.6.0D.R 3 × 380-415 V Y 1.5 3450 DOL 3.1 78.0 82.1 83.02 0.68 0.78 0.85 4 × 1.5 mm2

DWK.O.6.80.15.6.0E.R 3 × 220-240 V D 1.5 3450 DOL 5.1 78.0 82.1 83.02 0.68 0.78 0.85 4 × 1.5 mm2

Pump typeImpeller

type

Maximum solids size

[mm]

Maximum number of starts

per hour

Maximum installation depth [m]

Enclosure class

Insulation class

Maximum liquid temperature [°C]

pH

DWK.O.6.80.15.6 Semi-open 6 30 25 68 F 40 4-10

� � � � � �� �� �� �� �� �� �� �� �� ��� ���

��

��

��

���

� � � � � � � � �� ��

��

��

��

��

�������

������������������&

� �!!��"�����#

��

����

����

� � � � � �� �� �� �� �� �� �� �� �� ��� �����

���

���

���

���

$%��

�$�

�$�

49

Page 50: DWK pumps - api.grundfos.com

Pe

rform

an

ce

cu

rve

s a

nd

tec

hn

ica

l da

ta

50

10

DWK.O.6.80.22.6

Electrical data

Pump data

TM4

2945

211

6Pump type

Voltage[V]

P2 [kW]

RPMStarting method

IN ηmotor [%] Cos φCable

[A] 1/2 3/4 1/1 1/2 3/4 1/1

DWK.O.6.80.22.6.0D 3 × 380-415 V Y 2.2 3450 DOL 4.1 79.8 83.1 86.1 0.71 0.82 0.89 4 × 1.5 mm2 + 2 × 1 mm2

DWK.O.6.80.22.6.0E 3 × 220-240 V D 2.2 3450 DOL 7.1 79.8 83.1 86.1 0.71 0.82 0.89 4 × 1.5 mm2 + 2 × 1 mm2

DWK.O.6.80.22.6.0D.R 3 × 380-415 V Y 2.2 3450 DOL 4.1 79.8 83.1 86.1 0.71 0.82 0.89 4 × 1.5 mm2

DWK.O.6.80.22.6.0E.R 3 × 220-240 V D 2.2 3450 DOL 7.1 79.8 83.1 86.1 0.71 0.82 0.89 4 × 1.5 mm2

Pump typeImpeller

type

Maximum solids size

[mm]

Maximum number of starts

per hour

Maximum installation depth

[m]

Enclosure class

Insulation class

Maximum liquid temperature [°C]

pH

DWK.O.6.80.22.6 Semi-open 6 30 25 68 F 40 4-10

� � � � � �� �� �� �� �� �� �� �� �� �� �� ��� ���

��

��

��

��

��

��

���

� � � � � � � � � �� ��

��

��

��

��

�������

������������������&

� �!!��"�����#

��

��������

� � � � � �� �� �� �� �� �� �� �� �� �� �� ��� �����

���

���

���

���

���

$%��

�$��$�

Page 51: DWK pumps - api.grundfos.com

Pe

rfo

rma

nc

e c

urv

es

an

d t

ec

hn

ica

l d

ata

10

DWK.O.10.80.37.6

Electrical data

Pump data

TM4

2936

211

6Pump type

Voltage[V]

P2 [kW]

RPMStarting method

IN ηmotor [%] Cos φCable

[A] 1/2 3/4 1/1 1/2 3/4 1/1

DWK.O.10.80.37.6.0D 3 × 380-415 V Y 3.7 3450 DOL 7.2 86.0 87.2 86.5 0.84 0.88 0.90 4 × 1.5 mm2 + 2 × 1 mm2

DWK.O.10.80.37.6.0E 3 × 220-240 V D 3.7 3450 DOL 12.5 86.0 87.2 86.5 0.84 0.88 0.90 4 × 2.5 mm2 + 4 × 1 mm2

DWK.O.10.80.37.6.0D.R 3 × 380-415 V Y 3.7 3450 DOL 7.2 86.0 87.2 86.5 0.84 0.88 0.90 4 × 1.5 mm2

DWK.O.10.80.37.6.0E.R 3 × 220-240 V D 3.7 3450 DOL 12.5 86.0 87.2 86.5 0.84 0.88 0.90 4 × 2.5 mm2 + 4 × 1 mm2

Pump typeImpeller

type

Maximum solids size

[mm]

Maximum number of

starts per hour

Maximum installation depth [m]

Enclosure class

Insulation class

Maximum liquid temperature [°C]

pH

DWK.O.10.80.37.6 Semi-open 10 30 25 68 F 40 4-10

� � � �� �� �� �� �� �� �� �� �� �� �� ��� ���

��

��

��

��

��

��

���

� � � � � �� �� �� �� ��

��

��

��

��

��

�������

�������������������&

� �!!��"�����#

��

����

����

� � � �� �� �� �� �� �� �� �� �� �� �� ��� ���

$%��

�$��$�

51

Page 52: DWK pumps - api.grundfos.com

Pe

rform

an

ce

cu

rve

s a

nd

tec

hn

ica

l da

ta

52

10

DWK.O.13.80.55.6

Electrical data

Pump data

TM04

293

7 21

16Pump type

Voltage[V]

P2 [kW]

RPMStarting method

IN ηmotor [%] Cos φCable

[A] 1/2 3/4 1/1 1/2 3/4 1/1

DWK.O.13.80.55.6.0D 3 × 380-415 V Y 5.5 3450 DOL 10.5 88.5 89.5 88.6 0.86 0.89 0.915 4 × 2.5 mm2 + 4 × 1 mm2

DWK.O.13.80.55.6.0E 3 × 220-240 V D 5.5 3450 DOL 18.1 88.5 89.5 88.6 0.86 0.89 0.915 4 × 4.0 mm2 + 4 × 1 mm2

DWK.O.13.80.55.6.0D.R 3 × 380-415 V Y 5.5 3450 DOL 10.5 88.5 89.5 88.6 0.86 0.89 0.915 4 × 2.5 mm2 + 4 × 1 mm2

DWK.O.13.80.55.6.0E.R 3 × 220-240 V D 5.5 3450 DOL 18.1 88.5 89.5 88.6 0.86 0.89 0.915 4 × 4.0 mm2 + 4 × 1 mm2

DWK.O.13.80.55.6.1D 3 × 380-415 V D 5.5 3450 Y/D 10.5 88.5 89.5 88.6 0.86 0.89 0.915 7 × 4.0 mm2 + 4 × 1 mm2

DWK.O.13.80.55.6.1E 3 × 220-240 V D 5.5 3450 Y/D 18.1 88.5 89.5 88.6 0.86 0.89 0.915 7 × 4.0 mm2 + 4 × 1 mm2

DWK.O.13.80.55.6.1D.R 3 × 380-415 V D 5.5 3450 Y/D 10.5 88.5 89.5 88.6 0.86 0.89 0.915 7 × 4.0 mm2 + 4 × 1 mm2

DWK.O.13.80.55.6.1E.R 3 × 220-240 V D 5.5 3450 Y/D 18.1 88.5 89.5 88.6 0.86 0.89 0.915 7 × 4.0 mm2 + 4 × 1 mm2

Pump typeImpeller

type

Maximum solids size

[mm]

Maximum number of starts

per hour

Maximum installation depth [m]

Enclosure class

Insulation class

Maximum liquid temperature [°C]

pH

DWK.O.13.80.55.6 Semi-open 13 30 25 68 F 40 4-10

� � �� �� �� �� �� �� �� �� �� �� �� �� ��� ���

��

��

��

��

��

��

��

���

� � � � � �� �� �� �� �� �� ��

��

��

��

��

��

�������

�������������������&

� �!!��"�����#��

��������

� � �� �� �� �� �� �� �� �� �� �� �� �� ��� ���

$%��

�$�

�$�

Page 53: DWK pumps - api.grundfos.com

Pe

rfo

rma

nc

e c

urv

es

an

d t

ec

hn

ica

l d

ata

10

DWK.O.10.100.37.6

Electrical data

Pump data

TM04

294

6 21

16Pump type

Voltage[V]

P2 [kW]

RPMStarting method

IN ηmotor [%] Cos φCable

[A] 1/2 3/4 1/1 1/2 3/4 1/1

DWK.O.10.100.37.6.0D 3x380-415V Y 3.7 3450 DOL 7.2 86.0 87.2 86.5 0.84 0.88 0.90 4 × 1.5 mm2 + 2 × 1 mm2

DWK.O.10.100.37.6.0E 3x220-240V D 3.7 3450 DOL 12.5 86.0 87.2 86.5 0.84 0.88 0.90 4 × 2.5 mm2 + 4 × 1 mm2

DWK.O.10.100.37.6.0D.R 3x380-415V Y 3.7 3450 DOL 7.2 86.0 87.2 86.5 0.84 0.88 0.90 4 × 1.5 mm2

DWK.O.10.100.37.6.0E.R 3x220-240V D 3.7 3450 DOL 12.5 86.0 87.2 86.5 0.84 0.88 0.90 4 × 2.5 mm2 + 4 × 1 mm2

Pump typeImpeller

type

Maximum solids size

[mm]

Maximum number of

starts per hour

Maximum installation depth [m]

Enclosure class

Insulation class

Maximum liquid temperature [°C]

pH

DWK.O.10.100.37.6 Semi-open 10 30 25 68 F 40 4 - 10

� � �� �� �� �� �� �� �� �� �� �� �� �� ��� ���

��

��

��

��

��

��

���

� � � � � �� �� �� �� �� �� ��

��

��

��

��

��

�������

��������������������&

� �!!��"�����#

��

��������

� � �� �� �� �� �� �� �� �� �� �� �� �� ��� ���

$%��

�$��$�

53

Page 54: DWK pumps - api.grundfos.com

Pe

rform

an

ce

cu

rve

s a

nd

tec

hn

ica

l da

ta

54

10

DWK.O.13.100.55.6

Electrical data

Pump data

TM04

293

8 21

16Pump type

Voltage[V]

P2 [kW]

RPMStarting method

IN ηmotor [%] Cos φCable

[A] 1/2 3/4 1/1 1/2 3/4 1/1

DWK.O.13.100.55.6.0D 3 × 380-415 V Y 5.5 3450 DOL 10.5 88.5 89.5 88.6 0.86 0.89 0.915 4 × 2.5 mm2 + 4 × 1 mm2

DWK.O.13.100.55.6.0E 3 × 220-240 V D 5.5 3450 DOL 18.1 88.5 89.5 88.6 0.86 0.89 0.915 4 × 4.0 mm2 + 4 × 1 mm2

DWK.O.13.100.55.6.0D.R 3 × 380-415 V Y 5.5 3450 DOL 10.5 88.5 89.5 88.6 0.86 0.89 0.915 4 × 2.5 mm2 + 4 × 1 mm2

DWK.O.13.100.55.6.0E.R 3 × 220-240 V D 5.5 3450 DOL 18.1 88.5 89.5 88.6 0.86 0.89 0.915 4 × 4.0 mm2 + 4 × 1 mm2

DWK.O.13.100.55.6.1D 3 × 380-415 V D 5.5 3450 Y/D 10.5 88.5 89.5 88.6 0.86 0.89 0.915 7 × 4.0 mm2 + 4 × 1 mm2

DWK.O.13.100.55.6.1E 3 × 220-240 V D 5.5 3450 Y/D 18.1 88.5 89.5 88.6 0.86 0.89 0.915 7 × 4.0 mm2 + 4 × 1 mm2

DWK.O.13.100.55.6.1D.R 3 × 380-415 V Y 5.5 3450 Y/D 10.5 88.5 89.5 88.6 0.86 0.89 0.915 7 × 4.0 mm2 + 4 × 1 mm2

DWK.O.13.100.55.6.1E.R 3 × 220-240 V D 5.5 3450 Y/D 18.1 88.5 89.5 88.6 0.86 0.89 0.915 7 × 4.0 mm2 + 4 × 1 mm2

Pump typeImpeller

type

Maximum solids size

[mm]

Maximum number of

starts per hour

Maximum installation depth [m]

Enclosure class

Insulation class

Maximum liquid temperature [°C]

pH

DWK.O.13.100.55.6 Semi-open 13 30 25 68 F 40 4-10

� � �� �� �� �� �� �� �� �� �� �� �� �� �� �� ��� ���

��

��

��

��

��

��

���

� � � � � �� �� �� �� �� �� �� ��

��

��

��

��

��

�������

��������������������&

� �!!��"�����#

��

����

����

� � �� �� �� �� �� �� �� �� �� �� �� �� �� �� ��� ���

$%��

�$��$�

Page 55: DWK pumps - api.grundfos.com

Pe

rfo

rma

nc

e c

urv

es

an

d t

ec

hn

ica

l d

ata

10

DWK.O.13.100.75.6

Electrical data

Pump data

TM04

293

9 21

16Pump type

Voltage[V]

P2 [kW]

RPMStarting method

IN ηmotor [%] Cos φCable

[A] 1/2 3/4 1/1 1/2 3/4 1/1

DWK.O.13.100.75.6.0D 3 × 380-415 V Y 7.5 3450 DOL 14.0 89.5 90.1 89.1 0.87 0.90 0.92 4 × 4.0 mm2 + 4 × 1 mm2

DWK.O.13.100.75.6.0E 3 × 220-240V D 7.5 3450 DOL 24.3 89.5 90.1 89.1 0.87 0.90 0.92 4 × 6.0 mm2 + 4 × 1 mm2

DWK.O.13.100.75.6.0D.R 3 × 380-415 V Y 7.5 3450 DOL 14.0 89.5 90.1 89.1 0.87 0.90 0.92 4 × 4.0 mm2 + 4 × 1 mm2

DWK.O.13.100.75.6.0E.R 3 × 220-240 V D 7.5 3450 DOL 24.3 89.5 90.1 89.1 0.87 0.90 0.92 4 × 6.0 mm2 + 4 × 1 mm2

DWK.O.13.100.75.6.1D 3 × 380-415 V D 7.5 3450 Y/D 14.0 89.5 90.1 89.1 0.87 0.90 0.92 7 × 4.0 mm2 + 4 × 1 mm2

DWK.O.13.100.75.6.1E 3 × 220-240 V D 7.5 3450 Y/D 24.3 89.5 90.1 89.1 0.87 0.90 0.92 7 × 4.0 mm2 + 4 × 1 mm2

DWK.O.13.100.75.6.1D.R 3 × 380-415 V D 7.5 3450 Y/D 14.0 89.5 90.1 89.1 0.87 0.90 0.92 7 × 4.0 mm2 + 4 × 1 mm2

DWK.O.13.100.75.6.1E.R 3 × 220-240 V D 7.5 3450 Y/D 24.3 89.5 90.1 89.1 0.87 0.90 0.92 7 × 4.0 mm2 + 4 × 1 mm2

Pump typeImpeller

type

Maximum solids size

[mm]

Maximum number of starts

per hour

Maximum installation depth

[m]

Enclosure class

Insulation class

Maximum liquid temperature [°C]

pH

DWK.O.13.100.75.6 Semi-open 13 30 25 68 F 40 4-10

� � �� �� �� �� �� �� �� �� �� �� �� �� �� �� ����� ���

��

��

��

��

��

��

��

���

� � � � � �� �� �� �� �� �� �� �� ��

��

��

��

��

��

��

�������

��������������������&

� �!!��"�����#

��

����

����

� � �� �� �� �� �� �� �� �� �� �� �� �� �� �� ����� ���

��

$%��

�$��$�

55

Page 56: DWK pumps - api.grundfos.com

Pe

rform

an

ce

cu

rve

s a

nd

tec

hn

ica

l da

ta

56

10

DWK.O.13.100.110.6

Electrical data

Pump data

TM04

294

0 21

16

Pump typeVoltage

[V]P2

[kW]RPM

Starting method

IN ηmotor [%] Cos φCable

[A] 1/2 3/4 1/1 1/2 3/4 1/1

DWK.O.13.100.110.6.0D 3 × 380-415 V Y 11 3450 DOL 21.5 89.6 90.2 90.0 0.88 0.91 0.92 4 × 6.0 mm2 + 4 × 1 mm2

DWK.O.13.100.110.6.0E 3 × 220-240 V D 11 3450 DOL 35.3 89.6 90.2 90.0 0.88 0.91 0.92 4 × 10.0 mm2 + 6 × 1 mm2

DWK.O.13.100.110.6.0D.R 3 × 380-415 V Y 11 3450 DOL 21.5 89.6 90.2 90.0 0.88 0.91 0.92 4 × 6.0 mm2 + 4 × 1 mm2

DWK.O.13.100.110.6.0E.R 3 × 220-240 V D 11 3450 DOL 35.3 89.6 90.2 90.0 0.88 0.91 0.92 4 × 10.0 mm2 + 6 × 1 mm2

DWK.O.13.100.110.6.1D 3 × 380-415 V D 11 3450 Y/D 21.5 89.6 90.2 90.0 0.88 0.91 0.92 7 × 4.0 mm2 + 4 × 1 mm2

DWK.O.13.100.110.6.1E 3 × 220-240 V D 11 3450 Y/D 35.3 89.6 90.2 90.0 0.88 0.91 0.92 7 × 6.0 mm2 + 6 × 1 mm2

DWK.O.13.100.110.6.1D.R 3 × 380-415 V Y 11 3450 Y/D 21.5 89.6 90.2 90.0 0.88 0.91 0.92 7 × 4.0 mm2 + 4 × 1 mm2

DWK.O.13.100.110.6.1E.R 3 × 220-240 V D 11 3450 Y/D 35.3 89.6 90.2 90.0 0.88 0.91 0.92 7 × 6.0 mm2 + 6 × 1 mm2

Pump typeImpeller

type

Maximum solids size

[mm]

Maximum number of starts

per hour

Maximum installation depth

[m]

Enclosure class

Insulation class

Maximum liquid temperature [°C]

pH

DWK.O.13.100.110.6 Semi-open 13 30 25 68 F 40 4-10

� �� �� �� �� �� �� �� �� !� ��� ��� ���

��

��

��

��

��

��

��

��

���

� � �� �� �� �� �� �� ��

��

��

��

��

��

��

�������

���������������������&

� �!!��"�����#

��

��������

� �� �� �� �� �� �� �� �� !� ��� ��� ���

��

��

$%��

�$�

�$�

Page 57: DWK pumps - api.grundfos.com

Pe

rfo

rma

nc

e c

urv

es

an

d t

ec

hn

ica

l d

ata

10

DWK.O.13.100.150.6

Electrical data

Pump data

TM04

294

1 09

16Pump type

Voltage[V]

P2 [kW]

RPMStarting method

IN ηmotor [%] Cos φCable

[A] 1/2 3/4 1/1 1/2 3/4 1/1

DWK.O.13.100.150.6.0D 3 × 380-415 V Y 15 3450 DOL 27.8 89.7 90.2 90.2 0.89 0.91 0.92 4 × 6.0 mm2 + 4 × 1 mm2

DWK.O.13.100.150.6.0E 3 × 220-240 V D 15 3450 DOL 48.1 89.7 90.2 90.2 0.89 0.91 0.92 4 × 10.0 mm2 + 6 × 1 mm2

DWK.O.13.100.150.6.0D.R 3 × 380-415 V Y 15 3450 DOL 27.8 89.7 90.2 90.2 0.89 0.91 0.92 4 × 6.0 mm2 + 4 × 1 mm2

DWK.O.13.100.150.6.0E.R 3 × 220-240 V D 15 3450 DOL 48.1 89.7 90.2 90.2 0.89 0.91 0.92 4 × 10.0 mm2 + 6 × 1 mm2

DWK.O.13.100.150.6.1D 3 × 380-415 V D 15 3450 Y/D 27.8 89.7 90.2 90.2 0.89 0.91 0.92 7 × 4.0 mm2 + 4 × 1 mm2

DWK.O.13.100.150.6.1E 3 × 220-240 V D 15 3450 Y/D 48.1 89.7 90.2 90.2 0.89 0.91 0.92 7 × 6.0 mm2 + 6 × 1 mm2

DWK.O.13.100.150.6.1D.R 3 × 380-415 V D 15 3450 Y/D 27.8 89.7 90.2 90.2 0.89 0.91 0.92 7 × 4.0 mm2 + 4 × 1 mm2

DWK.O.13.100.150.6.1E.R 3 × 220-240 V D 15 3450 Y/D 48.1 89.7 90.2 90.2 0.89 0.91 0.92 7 × 6.0 mm2 + 6 × 1 mm2

Pump typeImpeller

type

Maximum solids size

[mm]

Maximum number of starts

per hour

Maximum installation depth

[m]

Enclosure class

Insulation class

Maximum liquid temperature [°C]

pH

DWK.O.13.100.150.6 Semi-open 13 30 25 68 F 40 4-10

� � �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� ��� ���

��

��

��

��

��

��

��

��

��

��

���

� � � � � �� �� �� �� �� �� �� �� �� ��

��

��

��

��

��

�������

���������������������&

� �!!��"�����#

��

��������

� � �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� �� ��� ���

��

��

��

��

$%��

�$�

�$�

57

Page 58: DWK pumps - api.grundfos.com

Pe

rform

an

ce

cu

rve

s a

nd

tec

hn

ica

l da

ta

58

10

DWK.O.13.150.75.6

Electrical data

Pump data

TM04

294

2 21

16Pump type

Voltage[V]

P2 [kW]

RPMStarting method

IN ηmotor [%] Cos φCable

[A] 1/2 3/4 1/1 1/2 3/4 1/1

DWK.O.13.150.75.6.0D 3 × 380-415 V Y 7.5 3450 DOL 14.0 89.5 90.1 89.1 0.87 0.90 0.92 4 × 4.0 mm2 + 4 × 1 mm2

DWK.O.13.150.75.6.0E 3 × 220-240 V D 7.5 3450 DOL 24.3 89.5 90.1 89.1 0.87 0.90 0.92 4 × 6.0 mm2 + 4 × 1 mm2

DWK.O.13.150.75.6.0D.R 3 × 380-415 V Y 7.5 3450 DOL 14.0 89.5 90.1 89.1 0.87 0.90 0.92 4 × 4.0 mm2 + 4 × 1 mm2

DWK.O.13.150.75.6.0E.R 3 × 220-240 V D 7.5 3450 DOL 24.3 89.5 90.1 89.1 0.87 0.90 0.92 4 × 6.0 mm2 + 4 × 1 mm2

DWK.O.13.150.75.6.1D 3 × 380-415 V D 7.5 3450 Y/D 14.0 89.5 90.1 89.1 0.87 0.90 0.92 7 × 4.0 mm2 + 4 × 1 mm2

DWK.O.13.150.75.6.1E 3 × 220-240 V D 7.5 3450 Y/D 24.3 89.5 90.1 89.1 0.87 0.90 0.92 7 × 4.0 mm2 + 4 × 1 mm2

DWK.O.13.150.75.6.1D.R 3 × 380-415 V D 7.5 3450 Y/D 14.0 89.5 90.1 89.1 0.87 0.90 0.92 7 × 4.0 mm2 + 4 × 1 mm2

DWK.O.13.150.75.6.1E.R 3 × 220-240 V D 7.5 3450 Y/D 24.3 89.5 90.1 89.1 0.87 0.90 0.92 7 × 4.0 mm2 + 4 × 1 mm2

Pump typeImpeller

type

Maximum solids size

[mm]

Maximum number of starts

per hour

Maximum installation depth

[m]

Enclosure class

Insulation class

Maximum liquid temperature [°C]

pH

DWK.O.13.150.75.6 Semi-open 13 30 25 68 F 40 4-10

� �� �� �� �� �� �� �� �� ��� ���

��

��

��

��

��

��

���

� � �� �� �� �� �� ��

��

��

��

��

��

�������

��������������������&

� �!!��"�����#��

����

����

� �� �� �� �� �� �� �� �� ��� ���

��

$%��

�$��$�

Page 59: DWK pumps - api.grundfos.com

Pe

rfo

rma

nc

e c

urv

es

an

d t

ec

hn

ica

l d

ata

10

DWK.O.13.150.110.6

Electrical data

Pump data

TM04

294

3 21

16Pump type

Voltage[V]

P2 [kW]

RPMStarting method

IN ηmotor [%] Cos φCable

[A] 1/2 3/4 1/1 1/2 3/4 1/1

DWK.O.13.150.110.6.0D 3 × 380-415 V Y 11 3450 DOL 21.5 89.6 90.2 90.0 0.88 0.91 0.92 4 × 6.0 mm2 + 4 × 1 mm2

DWK.O.13.150.110.6.0E 3 × 220-240 V D 11 3450 DOL 35.3 89.6 90.2 90.0 0.88 0.91 0.92 4 × 10.0 mm2 + 6 × 1 mm2

DWK.O.13.150.110.6.0D.R 3 × 380-415 V Y 11 3450 DOL 21.5 89.6 90.2 90.0 0.88 0.91 0.92 4 × 6.0 mm2 + 4 × 1 mm2

DWK.O.13.150.110.6.0E.R 3 × 220-240 V D 11 3450 DOL 35.3 89.6 90.2 90.0 0.88 0.91 0.92 4 × 10.0 mm2 + 6 × 1 mm2

DWK.O.13.150.110.6.1D 3 × 380-415 V D 11 3450 Y/D 21.5 89.6 90.2 90.0 0.88 0.91 0.92 7 × 4.0 mm2 + 4 × 1 mm2

DWK.O.13.150.110.6.1E 3 × 220-240 V D 11 3450 Y/D 35.3 89.6 90.2 90.0 0.88 0.91 0.92 7 × 6.0 mm 2+ 6 × 1 mm2

DWK.O.13.150.110.6.1D.R 3 × 380-415 V D 11 3450 Y/D 21.5 89.6 90.2 90.0 0.88 0.91 0.92 7 × 4.0 mm2 + 4 × 1 mm2

DWK.O.13.150.110.6.1E.R 3 × 220-240 V D 11 3450 Y/D 35.3 89.6 90.2 90.0 0.88 0.91 0.92 7 × 6.0 mm2 + 6 × 1 mm2

Pump typeImpeller

type

Maximum solids size

[mm]

Maximum number of starts

per hour

Maximum installation depth

[m]

Enclosure class

Insulation class

Maximum liquid temperature [°C]

pH

DWK.O.13.150.110.6 Semi-open 13 30 25 68 F 40 4-10

� �� �� �� �� �� �� �� �� !� ��� ��� ���

��

��

��

��

��

��

��

���

� � �� �� �� �� �� �� ��

��

��

��

��

��

��

�������

���������������������&

� �!!��"�����#

����

����

��

� �� �� �� �� �� �� �� �� !� ��� ��� ���

��

��

��

$%��

�$�

�$�

59

Page 60: DWK pumps - api.grundfos.com

Pe

rform

an

ce

cu

rve

s a

nd

tec

hn

ica

l da

ta

60

10

DWK.O.13.150.150.6

Electrical data

Pump data

TM04

294

4 21

16Pump type

Voltage[V]

P2 [kW]

RPMStarting method

IN ηmotor [%] Cos φCable

[A] 1/2 3/4 1/1 1/2 3/4 1/1

DWK.O.13.150.150.6.0D 3 × 380-415 V Y 15 3450 DOL 27.8 89.7 90.2 90.0 0.89 0.91 0.92 4 × 6.0 mm2 + 4 × 1 mm2

DWK.O.13.150.150.6.0E 3 × 220-240 V D 15 3450 DOL 48.1 89.7 90.2 90.0 0.89 0.91 0.92 4 × 10.0 mm2 + 6 × 1 mm2

DWK.O.13.150.150.6.0D.R 3 × 380-415 V Y 15 3450 DOL 27.8 89.7 90.2 90.0 0.89 0.91 0.92 4 × 6.0 mm2 + 4 × 1 mm2

DWK.O.13.150.150.6.0E.R 3 × 220-240 V D 15 3450 DOL 48.1 89.7 90.2 90.0 0.89 0.91 0.92 4 × 10.0 mm2 + 6 × 1 mm2

DWK.O.13.150.150.6.1D 3 × 380-415 V D 15 3450 Y/D 27.8 89.7 90.2 90.0 0.89 0.91 0.92 7 × 4.0 mm2 + 4 × 1 mm2

DWK.O.13.150.150.6.1E 3 × 220-240 V D 15 3450 Y/D 48.1 89.7 90.2 90.0 0.89 0.91 0.92 7 × 6.0 mm2+ 6 × 1 mm2

DWK.O.13.150.150.6.1D.R 3 × 380-415 V D 15 3450 Y/D 27.8 89.7 90.2 90.0 0.89 0.91 0.92 7 × 4.0 mm2 + 4 × 1 mm2

DWK.O.13.150.150.6.1E.R 3 × 220-240 V D 15 3450 Y/D 48.1 89.7 90.2 90.0 0.89 0.91 0.92 7 × 6.0 mm2 + 6 × 1 mm2

Pump typeImpeller

type

Maximum solids size

[mm]

Maximum number of starts

per hour

Maximum installation depth

[m]

Enclosure class

Insulation class

Maximum liquid temperature [°C]

pH

DWK.O.13.150.150.6 Semi-open 13 30 25 68 F 40 4-10

� �� �� �� �� �� �� �� �� !� ��� ��� ��� ���

��

��

��

��

��

��

��

��

���

� � �� �� �� �� �� �� ��

��

��

��

��

��

�������

���������������������&

� �!!��"�����#

��

����

����

� �� �� �� �� �� �� �� �� !� ��� ��� ��� ���

��

��

��

$%��

�$��$�

� �� �� �� �� �� �� �� �� !� ��� ��� ��� ���

��

��

��

��

��

��

��

��

���

� � �� �� �� �� �� �� ��

��

��

��

��

��

�������

���������������������&

� �!!��"�����#

��

����

����

� �� �� �� �� �� �� �� �� !� ��� ��� ��� ���

��

��

��

$%��

�$��$�

Page 61: DWK pumps - api.grundfos.com

Pe

rfo

rma

nc

e c

urv

es

an

d t

ec

hn

ica

l d

ata

10

DWK.E

DWK.E.10.100.220.6

Electrical data

DWK.E.10.100.220.6.1D.(R) - 3 × 380-415 V

DWK.E.10.100.220.6.1E.(R) - 3 × 220-240 V

Pump data

TM04

290

7 14

09

P1 P2 min-1 Starting

method

IN Istart [A] ηmotor [%] Cos φ Moment of inertia [kgm2]

Break down torque [N-m]

Cable [mm2]

[kW] [A] 380 V 400 V 415 V 1/2 3/4 1/1 1/2 3/4 1/1 [power-sensor]

24.7 22 3450 Y/D 44 253 213 204 85 86 87 0.75 0.82 0.86 0.20 152 6 × 10 + 1 × 6 + 6 × 1.5

P1 P2 min-1 Starting

method

IN Istart [A] ηmotor [%] Cos φ Moment of inertia [kgm2]

Break down torque [N-m]

Cable [mm2]

[kW] [A] 220 V 240 V 1/2 3/4 1/1 1/2 3/4 1/1 [power-sensor]

24.7 22 3450 Y/D 77 427 405 85 86 87 0.75 0.82 0.86 0.20 152 6 × 16 + 1 × 10 + 6 × 1.5

Pump typeImpeller

type

Maximum solids size

[mm]

Maximum number of starts

per hour

Maximum installation depth

[m]

Enclosure class

Insulation class

Maximum liquid temperature [°C]

pH

DWK.E.10.100.220.6 Enclosed 10 18 25 68 F 40 4-10

0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160Q [m³/h]0

10

20

30

40

50

60

70

80

90

H[m]

0 5 10 15 20 25 30 35 40 45 Q [l/s]

0

10

20

30

40

50

60

70[%]Eta

DWK.E.10.100.220.660 Hz

ISO 9906:2012 3B

QH Eta 2

Eta 1

0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160Q [m³/h]5

10

15

20

25

30

P[kW]

QP2QP1

61

Page 62: DWK pumps - api.grundfos.com

Pe

rform

an

ce

cu

rve

s a

nd

tec

hn

ica

l da

ta

62

10

DWK.E.10.150.220.6

Electrical data

DWK.E.10.150.220.6.1D.(R) - 3 × 380-415 V

DWK.E.10.150.220.6.1E.(R) - 3 × 220-240 V

Pump data

TM04

290

8 14

09

P1 P2 min-1 Starting

method

IN Istart [A] ηmotor [%] Cos φ Moment of inertia [kgm2]

Break down torque [N-m]

Cable [mm2]

[kW] [A] 380 V 400 V 415 V 1/2 3/4 1/1 1/2 3/4 1/1 [power-sensor]

24.7 22 3450 Y/D 44 247 234 226 85 87 87 0.75 0.82 0.86 0.20 152 6 × 10 + 1 × 6 + 6 × 1.5

P1 P2 min-1 Starting

method

IN Istart [A] ηmotor [%] Cos φ Moment of inertia [kgm2]

Break down torque [N-m]

Cable [mm2]

[kW] [A] 220 V 240 V 1/2 3/4 1/1 1/2 3/4 1/1 [power-sensor]

24.7 22 3450 Y/D 77 427 405 85 87 87 0.75 0.82 0.86 0.20 152 6 × 16 + 1 × 10 + 6 × 1.5

Pump typeImpeller

type

Maximum solids size

[mm]

Maximum number of starts

per hour

Maximum installation depth

[m]

Enclosure class

Insulation class

Maximum liquid temperature [°C]

pH

DWK.E.10.150.220.6 Enclosed 10 18 25 68 F 40 4-10

� �� �� �� �� �� �� �� �� !� ��� ��� ��� ��� ��� ��� ��� ���

��

��

��

��

��

��

��

��

!�

���

� � �� �� �� �� �� �� �� �� �� ��

��

��

��

��

��

��

�������

���������������������&

� �!!��"�����#

�� ����

����

� �� �� �� �� �� �� �� �� !� ��� ��� ��� ��� ��� ��� ��� ���

��

��

��

��

$%��

�$��$�

Page 63: DWK pumps - api.grundfos.com

Pe

rfo

rma

nc

e c

urv

es

an

d t

ec

hn

ica

l d

ata

10

DWK.E.10.150.300.6

Electrical data

DWK.E.10.150.300.6.1D.(R) - 3 × 380-415 V

DWK.E.10.150.300.6.1E.(R) - 3 × 220-240 V

Pump data

TM04

290

9 14

09

P1 P2 min-1 Starting

method

IN Istart [A] ηmotor [%] Cos φ Moment of inertia [kgm2]

Break down torque [N-m]

Cable [mm2]

[kW] [A] 380 V 400 V 415 V 1/2 3/4 1/1 1/2 3/4 1/1 [power-sensor]

33.4 30 3450 Y/D 60 345 292 280 85 86 87 0.75 0.83 0.86 0.28 207 6 × 16 + 1 × 10 + 6 × 1.5

P1 P2 min-1 Starting

method

IN Istart [A] ηmotor [%] Cos φ Moment of inertia [kgm2]

Break down torque [N-m]

Cable [mm2]

[kW] [A] 220 V 240 V 1/2 3/4 1/1 1/2 3/4 1/1 [power-sensor]

33.4 30 3450 Y/D 105 427 405 85 86 87 0.75 0.83 0.86 0.28 207 6 × 25 + 1 × 16 + 6 × 1.5

Pump typeImpeller

type

Maximum solids size

[mm]

Maximum number of starts

per hour

Maximum installation depth

[m]

Enclosure class

Insulation class

Maximum liquid temperature [°C]

pH

DWK.E.10.150.300.6 Enclosed 10 18 25 68 F 40 4-10

� �� �� �� �� �� �� �� �� !� ��� ��� ��� ��� ��� ������ ���

��

��

��

��

��

��

��

��

!�

���

� � �� �� �� �� �� �� �� �� ��

��

��

��

��

��

��

�������

���������������������&

� �!!��"�����#��

����

����

� �� �� �� �� �� �� �� �� !� ��� ��� ��� ��� ��� ������ ����

��

��

��

��

��

$%��

�$��$�

63

Page 64: DWK pumps - api.grundfos.com

Pe

rform

an

ce

cu

rve

s a

nd

tec

hn

ica

l da

ta

64

10

DWK.E.10.150.370.6

Electrical data

DWK.E.10.150.370.6.1D.(R) - 3 × 380-415 V

DWK.E.10.150.370.6.1E.(R) - 3 × 220-240 V

Pump data

TM4

2910

140

9

P1 P2 min-1 Starting

method

IN Istart [A] ηmotor [%] Cos φ Moment of inertia [kgm2]

Break down torque [N-m]

Cable [mm2]

[kW] [A] 380 V 400 V 415 V 1/2 3/4 1/1 1/2 3/4 1/1 [power-sensor]

41.1 37 3450 Y/D 74 107 341 327 85 87 87 0.75 0.83 0.86 0.98 245 6 × 16 + 1 × 10 + 6 × 1.5

P1 P2 min-1 Starting

method

IN Istart [A] ηmotor [%] Cos φ Moment of inertia [kgm2]

Break down torque [N-m]

Cable [mm2]

[kW] [A] 220 V 240 V 1/2 3/4 1/1 1/2 3/4 1/1 [power-sensor]

41.1 37 3450 Y/D 129 427 405 85 87 87 0.75 0.83 0.86 0.98 245 6 × 25 + 1 × 16 + 6 × 1.5

Pump typeImpeller

type

Maximum solids size

[mm]

Maximum number of starts per hour

Maximum installation depth

[m]

Enclosure class

Insulation class

Maximum liquid temperature [°C]

pH

DWK.E.10.150.370.6 Enclosed 10 18 25 68 F 40 4-10

0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150Q [m³/h]

0

10

20

30

40

50

60

70

80

90

H[m]

0 5 10 15 20 25 30 35 40 Q [l/s]

0

10

20

30

40

50

60

70[%]Eta

DWK.E.10.150.370.660 Hz

ISO 9906:2012 3B

QH

Eta 2

Eta 1

0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150Q [m³/h]

15

20

25

30

35

40

P[kW]

QP2

QP1

Page 65: DWK pumps - api.grundfos.com

Pe

rfo

rma

nc

e c

urv

es

an

d t

ec

hn

ica

l d

ata

10

DWK.E.10.150.450.6

Electrical data

DWK.E.10.150.450.6.1D.(R) - 3 × 380-415 V

DWK.E.10.150.450.6.1E.(R) - 3 × 220-240 V

Pump data

TM04

291

1 14

09

P1 P2 min-1 Starting

method

IN Istart [A] ηmotor [%] Cos φ Moment of inertia [kgm2]

Break down torque [N-m]

Cable [mm2]

[kW] [A] 380 V 400 V 415 V 1/2 3/4 1/1 1/2 3/4 1/1 [power-sensor]

49.8 45 3450 Y/D 90 495 413 395 85 87 87 0.76 0.83 0.87 1.20 298 6 × 16 + 1 × 10 + 6 × 1.5

P1 P2 min-1 Starting

method

IN Istart [A] ηmotor [%] Cos φ Moment of inertia [kgm2]

Break down torque [N-m]

Cable [mm2]

[kW] [A] 220 V 240 V 1/2 3/4 1/1 1/2 3/4 1/1 [power-sensor]

49.8 45 3450 Y/D 156 427 405 85 87 87 0.76 0.83 0.87 1.20 298 6 × 35 + 1 × 25 + 6 × 1.5

Pump typeImpeller

type

Maximum solids size

[mm]

Maximum number of starts

per hour

Maximum installation depth

[m]

Enclosure class

Insulation class

Maximum liquid temperature [°C]

pH

DWK.E.10.150.450.6 Enclosed 10 18 25 68 F 40 4-10

0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150Q [m³/h]

0

10

20

30

40

50

60

70

80

90

100

H[m]

0 5 10 15 20 25 30 35 40 Q [l/s]

0

10

20

30

40

50

60[%]Eta

DWK.E.10.150.450.660 Hz

ISO 9906:2012 3B

QH

Eta 2

Eta 1

0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150Q [m³/h]

20

25

30

35

40

45

P[kW]

QP2

QP1

65

Page 66: DWK pumps - api.grundfos.com

Pe

rform

an

ce

cu

rve

s a

nd

tec

hn

ica

l da

ta

66

10

DWK.E.10.150.550.6

Electrical data

DWK.E.10.150.550.6.1D.(R) - 3 × 380-415 V

DWK.E.10.150.550.6.1E.(R) - 3 × 220-240 V

Pump data

TM04

291

2 14

09

P1 P2 min-1 Starting

method

IN Istart [A] ηmotor [%] Cos φ Moment of inertia [kgm2]

Break down torque [N-m]

Cable [mm2]

[kW] [A] 380 V 400 V 415 V 1/2 3/4 1/1 1/2 3/4 1/1 [power-sensor]

60.7 55 3450 Y/D 110 605 503 481 85 87 88 0.76 0.83 0.87 1.41 365 6 × 25 + 1 × 16 + 6 × 1.5

P1 P2 min-1 Starting

method

IN Istart [A] ηmotor [%] Cos φ Moment of inertia [kgm2]

Break down torque [N-m]

Cable [mm2]

[kW] [A] 220 V 240 V 1/2 3/4 1/1 1/2 3/4 1/1 [power-sensor]

60.7 55 3450 Y/D 190 427 405 85 87 88 0.76 0.83 0.87 1.41 365 6 × 35 + 1 × 25 + 6 × 1.5

Pump typeImpeller

type

Maximum solids size

[mm]

Maximum number of starts

per hour

Maximum installation depth

[m]

Enclosure class

Insulation class

Maximum liquid temperature [°C]

pH

DWK.E.10.150.550.6 Enclosed 10 18 25 68 F 40 4-10

� �� �� �� �� ��� ��� ��� ��� ��� ���

��

��

��

��

��

��

��

��

!�

���

���

���

� �� �� �� �� �� �� ��

��

��

��

��

��

�������

���������������������&

� �!!��"�����#

��

����

����

� �� �� �� �� ��� ��� ��� ��� ��� ����

��

��

��

��

��

$%��

�$��$�

Page 67: DWK pumps - api.grundfos.com

Pe

rfo

rma

nc

e c

urv

es

an

d t

ec

hn

ica

l d

ata

10

DWK.E.10.200.300.6

Electrical data

DWK.E.10.200.300.6.1D.(R) - 3 × 380-415 V

DWK.E.10.1200.300.6.1E.(R) - 3 × 220-240 V

Pump data

TM04

294

8 14

09

P1 P2 min-1 Starting

method

IN Istart [A] ηmotor [%] Cos φ Moment of inertia [kgm2]

Break down torque [N-m]

Cable [mm2]

[kW] [A] 380 V 400 V 415 V 1/2 3/4 1/1 1/2 3/4 1/1 [power-sensor]

33.4 30 3450 Y/D 60 345 292 280 85 84 87 0.75 0.83 0.86 0.28 207 6 × 16 + 1 × 10 + 6 × 1.5

P1 P2 min-1 Starting

method

IN Istart [A] ηmotor [%] Cos φ Moment of inertia [kgm2]

Break down torque [N-m]

Cable [mm2]

[kW] [A] 220 V 240 V 1/2 3/4 1/1 1/2 3/4 1/1 [power-sensor]

33.4 30 3450 Y/D 105 427 405 85 84 87 0.75 0.83 0.86 0.28 207 6 × 25 + 1 × 16 + 6 × 1.5

Pump typeImpeller

type

Maximum solids size

[mm]

Maximum number of starts

per hour

Maximum installation depth

[m]

Enclosure class

Insulation class

Maximum liquid temperature [°C]

pH

DWK.E.10.200.300.6 Enclosed 10 18 25 68 F 40 4-10

� �� �� �� �� ��� ��� ��� ��� ��� ��� ��� ��� ���

��

��

��

��

��

��

��

��

��

���

� �� �� �� �� �� �� �� ��

��

��

��

��

��

�������

���������������������&

� �!!��"�����#

��

����

����

� �� �� �� �� ��� ��� ��� ��� ��� ��� ��� ��� ����

��

��

��

��

��

$%��

�$�

�$�

67

Page 68: DWK pumps - api.grundfos.com

Pe

rform

an

ce

cu

rve

s a

nd

tec

hn

ica

l da

ta

68

10

DWK.E.10.200.370.6

Electrical data

DWK.E.10.200.370.6.1D.(R) - 3 × 380-415 V

DWK.E.10.200.370.6.1E.(R) - 3 × 220-240 V

Pump data

TM04

291

3 14

09

P1 P2 min-1 Starting

method

IN Istart [A] ηmotor [%] Cos φ Moment of inertia [kgm2]

Break down torque [N-m]

Cable [mm2]

[kW] [A] 380 V 400 V 415 V 1/2 3/4 1/1 1/2 3/4 1/1 [power-sensor]

41.1 37 3450 Y/D 74 407 341 327 85 87 87 0.75 0.83 0.86 0.98 245 6 × 16 + 1 × 10 + 6 × 1.5

P1 P2 min-1 Starting

method

IN Istart [A] ηmotor [%] Cos φ Moment of inertia [kgm2]

Break down torque [N-m]

Cable [mm2]

[kW] [A] 220 V 240 V 1/2 3/4 1/1 1/2 3/4 1/1 [power-sensor]

41.1 37 3450 Y/D 129 427 405 85 87 87 0.75 0.83 0.86 0.98 245 6 × 25 + 1 × 16 + 6 × 1.5

Pump typeImpeller

type

Maximum solids size

[mm]

Maximum number of starts

per hour

Maximum installation depth

[m]

Enclosure class

Insulation class

Maximum liquid temperature [°C]

pH

DWK.E.10.200.370.6 Enclosed 10 18 25 68 F 40 4-10

� �� �� �� �� ��� ��� ��� ��� ��� ��� ��� ��� ��� ��� ������ ���

��

��

��

��

��

��

��

��

!�

���

� �� �� �� �� �� �� �� �� �� ��

��

��

��

��

��

��

�������

���������������������&

� �!!��"�����#

��

����

����

� �� �� �� �� ��� ��� ��� ��� ��� ��� ��� ��� ��� ��� ������ ����

��

��

��

��

��

$%��

�$�

�$�

Page 69: DWK pumps - api.grundfos.com

Pe

rfo

rma

nc

e c

urv

es

an

d t

ec

hn

ica

l d

ata

10

DWK.E.10.200.450.6

Electrical data

DWK.E.10.200.450.6.1D.(R) - 3 × 380-415 V

DWK.E.10.200.450.6.1E.(R) - 3 × 220-240 V

Pump data

TM04

291

4 14

09

P1 P2 min-1 Starting

method

IN Istart [A] ηmotor [%] Cos φ Moment of inertia [kgm2]

Break down torque [N-m]

Cable [mm2]

[kW] [A] 380 V 400 V 415 V 1/2 3/4 1/1 1/2 3/4 1/1 [power-sensor]

49.8 45 3450 Y/D 90 495 413 395 85 87 87 0.76 0.83 0.87 1.20 298 6 × 16 + 1 × 10 + 6 × 1.5

P1 P2 min-1 Starting

method

IN Istart [A] ηmotor [%] Cos φ Moment of inertia [kgm2]

Break down torque [N-m]

Cable [mm2]

[kW] [A] 220 V 240 V 1/2 3/4 1/1 1/2 3/4 1/1 [power-sensor]

49.8 45 3450 Y/D 156 427 405 85 87 87 0.76 0.83 0.87 1.20 298 6 × 35 + 1 × 25 + 6 × 1.5

Pump typeImpeller

type

Maximum solids size

[mm]

Maximum number of starts

per hour

Maximum installation depth

[m]

Enclosure class

Insulation class

Maximum liquid temperature [°C]

pH

DWK.E.10.200.450.6 Enclosed 10 18 25 68 F 40 4-10

0 20 40 60 80 100 120 140 160 180 200 220 240 260 280 300 Q [m³/h]

0

10

20

30

40

50

60

70

80

90

H[m]

0 10 20 30 40 50 60 70 80 90 Q [l/s]

0

10

20

30

40

50

60

70[%]Eta

DWK.E.10.200.450.660 Hz

ISO 9906:2012 3B

QHEta 2

Eta 1

0 20 40 60 80 100 120 140 160 180 200 220 240 260 280 300 Q [m³/h]

0

10

20

30

40

50

P[kW]

QP2QP1

69

Page 70: DWK pumps - api.grundfos.com

Pe

rform

an

ce

cu

rve

s a

nd

tec

hn

ica

l da

ta

70

10

DWK.E.10.200.550.6

Electrical data

DWK.E.10.200.550.6.1D.(R) - 3 × 380-415 V

DWK.E.10.200.550.6.1E.(R) - 3 × 220-240 V

Pump data

TM04

291

5 14

09

P1 P2 min-1 Starting

method

IN Istart [A] ηmotor [%] Cos φ Moment of inertia [kgm2]

Break down torque [N-m]

Cable [mm2]

[kW] [A] 380 V 400 V 415 V 1/2 3/4 1/1 1/2 3/4 1/1 [power-sensor]

60.7 55 3450 Y/D 110 605 503 481 85 87 88 0.76 0.83 0.87 1.41 365 6 × 25 + 1 × 16 + 6 × 1.5

P1 P2 min-1 Starting

method

IN Istart [A] ηmotor [%] Cos φ Moment of inertia [kgm2]

Break down torque [N-m]

Cable [mm2]

[kW] [A] 220 V 240 V 1/2 3/4 1/1 1/2 3/4 1/1 [power-sensor]

60.7 55 3450 Y/D 190 427 405 85 87 88 0.76 0.83 0.87 1.41 365 6 × 35 + 1 × 25 + 6 × 1.5

Pump typeImpeller

type

Maximum solids size

[mm]

Maximum number of starts

per hour

Maximum installation depth

[m]

Enclosure class

Insulation class

Maximum liquid temperature [°C]

pH

DWK.E.10.200.550.6 Enclosed 10 18 25 68 F 40 4-10

0 20 40 60 80 100 120 140 160 180 200 220 240 260 280 300 320 Q [m³/h]

0

10

20

30

40

50

60

70

80

90

H[m]

0 10 20 30 40 50 60 70 80 90 Q [l/s]

0

10

20

30

40

50

60

70[%]Eta

DWK.E.10.200.550.660 Hz

ISO 9906:2012 3BQH

Eta 2Eta 1

0 20 40 60 80 100 120 140 160 180 200 220 240 260 280 300 320 Q [m³/h]

20

30

40

50

60

P[kW]

QP2

QP1

Page 71: DWK pumps - api.grundfos.com

Pe

rfo

rma

nc

e c

urv

es

an

d t

ec

hn

ica

l d

ata

10

DWK.E.10.200.750.6

Electrical data

DWK.E.10.200.750.6.1D.(R) - 3 × 380-415 V

DWK.E.10.200.750.6.1E.(R) - 3 × 220-240 V

* 2EA = two power cables.

Pump data

TM05

291

6 14

09

P1 P2 min-1 Starting

method

IN Istart [A] ηmotor [%] Cos φ Moment of inertia [kgm2]

Break down torque [N-m]

Cable [mm2]

[kW] [A] 380 V 400 V 415 V 1/2 3/4 1/1 1/2 3/4 1/1 [power-sensor]

82.6 75 3450 Y/D 149 820 683 654 85 87 88 0.76 0.84 0.87 1.68 498 6 × 35 + 1 × 25 + 6 × 1.5

P1 P2 min-1 Starting

method

IN Istart [A] ηmotor [%] Cos φ Moment of inertia [kgm2]

Break down torque [N-m]

Cable [mm2]

[kW] [A] 220 V 240 V 1/2 3/4 1/1 1/2 3/4 1/1 [power-sensor]

82.6 75 3450 Y/D 257 427 405 85 87 88 0.76 0.84 0.87 1.68 498 3 × 50 + 1 × 35+ 4 × 1.5, 2EA*

Pump typeImpeller

type

Maximum solids size

[mm]

Maximum number of starts

per hour

Maximum installation depth

[m]

Enclosure class

Insulation class

Maximum liquid temperature [°C]

pH

DWK.E.10.200.750.6 Enclosed 10 18 25 68 F 40 4-10

0 20 40 60 80 100 120 140 160 180 200 220 240 260 280 300 320 Q [m³/h]

0

10

20

30

40

50

60

70

80

90

H[m]

0 10 20 30 40 50 60 70 80 90 Q [l/s]

0

10

20

30

40

50

60

70[%]Eta

DWK.E.10.200.750.660 Hz

ISO 9906:2012 3BQH

Eta 2

Eta 1

0 20 40 60 80 100 120 140 160 180 200 220 240 260 280 300 320 Q [m³/h]

30

40

50

60

70

80

P[kW]

QP1

QP2

71

Page 72: DWK pumps - api.grundfos.com

Pe

rform

an

ce

cu

rve

s a

nd

tec

hn

ica

l da

ta

72

10

DWK.E.10.200.900.6

Electrical data

DWK.E.10.150.750.6.1D.(R) - 3 × 380-415 V

* 2EA = two power cables.

Pump data

TM04

291

7 14

09

P1 P2 min-1 Starting

method

IN Istart [A] ηmotor [%] Cos φ Moment of inertia

[kgm2]

Break down torque [N-m]

Cable [mm2]

[kW] [A] 380 V 400 V 415 V 1/2 3/4 1/1 1/2 3/4 1/1 [power-sensor]

98.9 90 3450 Y/D 177 974 816 781 86 88 89 0.76 0.84 0.87 2.70 597 3 × 50 + 1 × 35 + 4 × 1.5, 2EA*

Pump typeImpeller

type

Maximum solids size

[mm]

Maximum number of starts

per hour

Maximum installation depth

[m]

Enclosure class

Insulation class

Maximum liquid temperature [°C]

pH

DWK.E.10.200.900.6 Enclosed 10 18 25 68 F 40 4-10

0 20 40 60 80 100 120 140 160 180 200 220 240 260 280 300 320 340 Q [m³/h]

0

10

20

30

40

50

60

70

80

90

100

H[m]

0 10 20 30 40 50 60 70 80 90 100 Q [l/s]

0

10

20

30

40

50

60

70[%]Eta

DWK.E.10.200.900.660 Hz

ISO 9906:2012 3B

QH

Eta 2

Eta 1

0 20 40 60 80 100 120 140 160 180 200 220 240 260 280 300 320 340 Q [m³/h]

40

50

60

70

80

90

100

P[kW]

QP2

QP1

Page 73: DWK pumps - api.grundfos.com

Pe

rfo

rma

nc

e c

urv

es

an

d t

ec

hn

ica

l d

ata

10

DWK.H

DWK.H.7.80.110.6

Electrical data

DWK.H.7.80.110.6.0D - 3 × 380-415 V

DWK.H.7.80.110.6.0E - 3 × 220-240 V

* 2EA = two power cables.

Pump data

TM06

989

4 35

17

P1 P2 min-1 Starting

method

IN Istart [A] ηmotor [%] Cos φ Moment of inertia [kgm2]

Break down torque [N-m]

Cable [mm2]

[kW] [A] 380 V 400 V 415 V 1/2 3/4 1/1 1/2 3/4 1/1 [power-sensor-ground]

13.04 11 3450 DOL 23 132 127 121 82 84 83 0.72 0.80 0.83 0.037 210 3 × 10 + 6 × 1.0 + 1 × 4

P1 P2 min-1 Starting

method

IN Istart [A] ηmotor [%] Cos φ Moment of inertia [kgm2]

Break down torque [N-m]

Cable [mm2]

[kW] [A] 220 V 240 V 1/2 3/4 1/1 1/2 3/4 1/1 [power-sensor-ground]

13.04 11 3450 DOL 23 226 209 82 84 83 0.72 0.80 0.83 0.037 210 3 × 16 + 10 × 1.0 + 4 × 1.5, 2EA*

Pump typeImpeller

type

Maximum solids size

[mm]

Maximum number of starts

per hour

Maximum installation depth

[m]

Enclosure class

Insulation class

Maximum liquid temperature [°C]

pH

DWK.H.7.80.110.6 Enclosed 7 10 25 68 F 40 4-10

0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80Q [m³/h]

0

10

20

30

40

50

60

70

80

90

100

H[m]

0 2 4 6 8 10 12 14 16 18 20 22 Q [l/s]

0

10

20

30

40

50

60[%]Eta

DWK.H.7.100.220.660 Hz

ISO 9906:2012 3B

QH

Eta 2

Eta 1

0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80Q [m³/h]

4

8

12

16

20

24

P[kW]

QP2

QP1

0 5 10 15 20 25 30 35 40 45 50 55 60 65 Q [m³/h]

0

10

20

30

40

50

60

70

80

H[m]

0 2 4 6 8 10 12 14 16 18 Q [l/s]

0

10

20

30

40

50

60[%]Eta

DWK.H.7.80.110.660 Hz

ISO 9906:2012 3BQH

Eta 2

Eta 1

0 5 10 15 20 25 30 35 40 45 50 55 60 65 Q [m³/h]

4

6

8

10

12

P[kW]

QP2

QP1

73

Page 74: DWK pumps - api.grundfos.com

Pe

rform

an

ce

cu

rve

s a

nd

tec

hn

ica

l da

ta

74

10

DWK.H.7.80.150.6

Electrical data

DWK.H.7.80.150.6.0D - 3 × 380-415 V

DWK.H.7.80.150.6.0E - 3 × 220-240 V

Pump data

TM06

989

5 35

17

P1 P2 min-1 Starting

method

IN Istart [A] ηmotor [%] Cos φ Moment of inertia [kgm2]

Break down torque [N-m]

Cable [mm2]

[kW] [A] 380 V 400 V 415 V 1/2 3/4 1/1 1/2 3/4 1/1 [power-sensor-ground]

17.6 15 3450 DOL 32 176 165 160 83 85 85 0.73 0.80 0.84 0.041 220 3 × 10 + 6 × 1.0 + 1 × 4

P1 P2 min-1 Starting

method

IN Istart [A] ηmotor [%] Cos φ Moment of inertia [kgm2]

Break down torque [N-m]

Cable [mm2]

[kW] [A] 220 V 240 V 1/2 3/4 1/1 1/2 3/4 1/1 [power-sensor-ground]

17.6 15 3450 DOL 32 303 281 83 85 85 0.73 0.80 0.84 0.041 220 3 × 16 + 10 × 1.0 + 1.5 × 4

Pump typeImpeller

type

Maximum solids size

[mm]

Maximum number of starts

per hour

Maximum installation depth

[m]

Enclosure class

Insulation class

Maximum liquid temperature [°C]

pH

DWK.H.7.80.110.6 Enclosed 7 10 25 68 F 40 4-10

0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80Q [m³/h]

0

10

20

30

40

50

60

70

80

90

100

H[m]

0 2 4 6 8 10 12 14 16 18 20 22 Q [l/s]

0

10

20

30

40

50

60[%]Eta

DWK.H.7.100.220.660 Hz

ISO 9906:2012 3B

QH

Eta 2

Eta 1

0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80Q [m³/h]

4

8

12

16

20

24

P[kW]

QP2

QP1

0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 Q [m³/h]

0

10

20

30

40

50

60

70

80

90

H[m]

0 2 4 6 8 10 12 14 16 18 20 Q [l/s]

0

10

20

30

40

50

60[%]Eta

DWK.H.7.80.150.660 Hz

ISO 9906:2012 3B

QH

Eta 2

Eta 1

0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 Q [m³/h]

6

8

10

12

14

16

18

P[kW]

QP2

QP1

Page 75: DWK pumps - api.grundfos.com

Pe

rfo

rma

nc

e c

urv

es

an

d t

ec

hn

ica

l d

ata

10

DWK.H.7.100.220.6

Electrical data

DWK.H.7.100.220.6.1D - 3 × 380-415 V

DWK.H.7.100.220.6.1E - 3 × 220-240 V

Pump data

TM06

989

6 35

17

P1 P2 min-1 Starting

method

IN Istart [A] ηmotor [%] Cos φ Moment of inertia [kgm2]

Break down torque [N-m]

Cable [mm2]

[kW] [A] 380 V 400 V 415 V 1/2 3/4 1/1 1/2 3/4 1/1 [power-sensor-ground]

24.7 22 3450 Y/D 44 253 213 204 85 86 87 0.75 0.82 0.86 0.20 152 6 × 10 + 6 × 1.5 + 1 × 6

P1 P2 min-1 Starting

method

IN Istart [A] ηmotor [%] Cos φ Moment of inertia [kgm2]

Break down torque [N-m]

Cable [mm2]

[kW] [A] 220 V 240 V 1/2 3/4 1/1 1/2 3/4 1/1 [power-sensor-ground]

24.7 22 3450 Y/D 77 427 405 85 86 87 0.75 0.82 0.86 0.20 152 6 × 16 + 6 × 1.5 + 1 × 10

Pump typeImpeller

type

Maximum solids size

[mm]

Maximum number of starts

per hour

Maximum installation depth

[m]

Enclosure class

Insulation class

Maximum liquid temperature [°C]

pH

DWK.H.7.100.220.6 Enclosed 7 10 25 68 F 40 4-10

0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80Q [m³/h]

0

10

20

30

40

50

60

70

80

90

100

H[m]

0 2 4 6 8 10 12 14 16 18 20 22 Q [l/s]

0

10

20

30

40

50

60[%]Eta

DWK.H.7.100.220.660 Hz

ISO 9906:2012 3B

QH

Eta 2

Eta 1

0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80Q [m³/h]

4

8

12

16

20

24

P[kW]

QP2

QP1

75

Page 76: DWK pumps - api.grundfos.com

Pe

rform

an

ce

cu

rve

s a

nd

tec

hn

ica

l da

ta

76

10

DWK.H.7.100.300.6

Electrical data

DWK.H.7.100.300.6.1D - 3 × 380-415 V

DWK.H.7.100.300.6.1E - 3 × 220-240 V

Pump data

TM06

989

7 35

17

P1 P2 min-1 Starting

method

IN Istart [A] ηmotor [%] Cos φ Moment of inertia [kgm2]

Break down torque [N-m]

Cable [mm2]

[kW] [A] 380 V 400 V 415 V 1/2 3/4 1/1 1/2 3/4 1/1 [power-sensor-ground]

33.4 30 3450 Y/D 60 345 292 280 85 86 87 0.75 0.83 0.86 0.28 207 6 × 16+ 6 × 1.5 + 1 × 10

P1 P2 min-1 Starting

method

IN Istart [A] ηmotor [%] Cos φ Moment of inertia [kgm2]

Break down torque [N-m]

Cable [mm2]

[kW] [A] 220 V 240 V 1/2 3/4 1/1 1/2 3/4 1/1 [power-sensor-ground]

33.4 30 3450 Y/D 105 427 405 85 86 87 0.75 0.83 0.86 0.28 207 6 × 25 + 6 × 1.5 + 1 × 16

Pump typeImpeller

type

Maximum solids size

[mm]

Maximum number of starts

per hour

Maximum installation depth

[m]

Enclosure class

Insulation class

Maximum liquid temperature [°C]

pH

DWK.H.7.100.300.6 Enclosed 7 10 25 68 F 40 4-10

0 10 20 30 40 50 60 70 80 90 100 110 Q [m³/h]

0

20

40

60

80

100

120

140

160

H[m]

0 5 10 15 20 25 30 Q [l/s]

0

10

20

30

40

50

60[%]Eta

DWK.H.7.100.300.660 Hz

ISO 9906:2012 3B

QH Eta 2

Eta 1

0 10 20 30 40 50 60 70 80 90 100 110 Q [m³/h]

10

15

20

25

30

35

P[kW]

QP2

QP1

Page 77: DWK pumps - api.grundfos.com

Pe

rfo

rma

nc

e c

urv

es

an

d t

ec

hn

ica

l d

ata

10

DWK.H.7.100.370.6

Electrical data

DWK.H.7.100.370.5.1D - 3 × 380-415 V

DWK.H.7.100.370.5.1E - 3 × 220-240 V

Pump data

TM06

989

8 35

17

P1 P2 min-1 Starting

method

IN Istart [A] ηmotor [%] Cos φ Moment of inertia [kgm2]

Break down torque [N-m]

Cable [mm2]

[kW] [A] 380 V 400 V 415 V 1/2 3/4 1/1 1/2 3/4 1/1 [power-sensor-ground]

41.1 37 3450 Y/D 74 407 341 327 75 87 87 0.75 0.83 0.86 0.98 245 6 × 16+ 6 × 1.5 + 1 × 10

P1 P2 min-1 Starting

method

IN Istart [A] ηmotor [%] Cos φ Moment of inertia [kgm2]

Break down torque [N-m]

Cable [mm2]

[kW] [A] 220 V 240 V 1/2 3/4 1/1 1/2 3/4 1/1 [power-sensor-ground]

41.1 37 3450 Y/D 129 427 405 75 87 87 0.75 0.83 0.86 0.98 245 6 × 25 + 6 × 1.5 + 1 × 16

Pump typeImpeller

type

Maximum solids size

[mm]

Maximum number of starts

per hour

Maximum installation depth

[m]

Enclosure class

Insulation class

Maximum liquid temperature [°C]

pH

DWK.H.7.100.370.6 Enclosed 7 10 25 68 F 40 4-10

0 10 20 30 40 50 60 70 80 90 100 110 120 Q [m³/h]

0

20

40

60

80

100

120

140

160

H[m]

0 5 10 15 20 25 30 35 Q [l/s]

0

10

20

30

40

50

60[%]Eta

DWK.H.7.100.370.660 Hz

ISO 9906:2012 3B

QHEta 2

Eta 1

0 10 20 30 40 50 60 70 80 90 100 110 120 Q [m³/h]

15

20

25

30

35

40

45

P[kW]

QP2

QP1

77

Page 78: DWK pumps - api.grundfos.com

Pe

rform

an

ce

cu

rve

s a

nd

tec

hn

ica

l da

ta

78

10

DWK.H.7.150.450.6

Electrical data

DWK.H.7.150.450.6.1D - 3 × 380-415 V

DWK.H.7.150.450.6.1E - 3 × 220-240 V

Pump data

TM06

989

9 35

17

P1 P2 min-1 Starting

method

IN Istart [A] ηmotor [%] Cos φ Moment of inertia [kgm2]

Break down torque [N-m]

Cable [mm2]

[kW] [A] 380 V 400 V 415 V 1/2 3/4 1/1 1/2 3/4 1/1 [power-sensor-ground]

49.8 45 3450 Y/D 90 495 413 395 85 87 87 0.76 0.83 0.87 1.20 298 6 × 16+ 6 × 1.5 + 1 × 10

P1 P2 min-1 Starting

method

IN Istart [A] ηmotor [%] Cos φ Moment of inertia [kgm2]

Break down torque [N-m]

Cable [mm2]

[kW] [A] 220 V 240 V 1/2 3/4 1/1 1/2 3/4 1/1 [power-sensor-ground]

49.8 45 3450 Y/D 156 427 405 87 83 76 0.88 0.90 0.90 1.24 362 6 × 35 + 6 × 1.5 + 1 × 25

Pump typeImpeller

type

Maximum solids size

[mm]

Maximum number of starts

per hour

Maximum installation depth

[m]

Enclosure class

Insulation class

Maximum liquid temperature [°C]

pH

DWK.H.7.150.450.6 Enclosed 7 10 25 68 F 40 4-10

0 10 20 30 40 50 60 70 80 90 100 110 Q [m³/h]

0

20

40

60

80

100

120

140

160

H[m]

0 5 10 15 20 25 30 Q [l/s]

0

10

20

30

40

50

60[%]Eta

DWK.H.7.150.450.660 Hz

ISO 9906:2012 3BQH

Eta 2

Eta 1

0 10 20 30 40 50 60 70 80 90 100 110 Q [m³/h]

20

25

30

35

40

45

50

P[kW]

QP2

QP1

Page 79: DWK pumps - api.grundfos.com

Pe

rfo

rma

nc

e c

urv

es

an

d t

ec

hn

ica

l d

ata

10

DWK.H.7.150.550.6

Electrical data

DWK.H.7.150.550.6.1D - 3 × 380-415 V

DWK.H.7.150.550.6.1E - 3 × 220-240 V

Pump data

TM06

990

0 35

17

P1 P2 min-1 Starting

method

IN Istart [A] ηmotor [%] Cos φ Moment of inertia [kgm2]

Break down torque [N-m]

Cable [mm2]

[kW] [A] 380 V 400 V 415 V 1/2 3/4 1/1 1/2 3/4 1/1 [power-sensor-ground]

60.7 55 3450 Y/D 110 605 503 481 85 87 88 0.76 0.83 0.87 1.41 365 6 × 25 + 6 × 1.5 + 1 × 16

P1 P2 min-1 Starting

method

IN Istart [A] ηmotor [%] Cos φ Moment of inertia [kgm2]

Break down torque [N-m]

Cable [mm2]

[kW] [A] 220 V 240 V 1/2 3/4 1/1 1/2 3/4 1/1 [power-sensor-ground]

60.7 55 3450 Y/D 190 427 405 87 83 76 0.88 0.90 0.91 1.46 442 6 × 35 + 6 × 1.5 + 1 × 25

Pump typeImpeller

type

Maximum solids size

[mm]

Maximum number of starts

per hour

Maximum installation depth

[m]

Enclosure class

Insulation class

Maximum liquid temperature [°C]

pH

DWK.H.7.150.550.6 Enclosed 7 10 25 68 F 40 4-10

0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160Q [m³/h]

0

20

40

60

80

100

120

140

160

H[m]

0 5 10 15 20 25 30 35 40 45 Q [l/s]

0

10

20

30

40

50

60[%]Eta

DWK.H.7.150.550.660 Hz

ISO 9906:2012 3BQH

Eta 2

Eta 1

0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160Q [m³/h]

20

30

40

50

60

P[kW]

QP2QP1

79

Page 80: DWK pumps - api.grundfos.com

Pe

rform

an

ce

cu

rve

s a

nd

tec

hn

ica

l da

ta

80

10

DWK.H.7.150.750.6

Electrical data

DWK.H.7.150.750.6.1D - 3 × 380-415 V

DWK.H.7.150.750.6.1E - 3 × 220-240 V

* 2EA = two power cables.

Pump data

TM06

990

1 35

17

P1 P2 min-1 Starting

method

IN Istart [A] ηmotor [%] Cos φ Moment of inertia [kgm2]

Break down torque [N-m]

Cable [mm2]

[kW] [A] 380 V 400 V 415 V 1/2 3/4 1/1 1/2 3/4 1/1 [power-sensor-ground]

82.6 75 3450 Y/D 149 820 683 654 85 87 88 0.76 0.84 0.87 1.68 498 6 × 35 + 6 × 1.5 + 1 × 25

P1 P2 min-1 Starting

method

IN Istart [A] ηmotor [%] Cos φ Moment of inertia [kgm2]

Break down torque [N-m]

Cable [mm2]

[kW] [A] 220 V 240 V 1/2 3/4 1/1 1/2 3/4 1/1 [power-sensor-ground]

82.6 75 3450 Y/D 257 427 405 85 87 88 0.76 0.84 0.87 1.68 498 3 × 50 + 1 × 35 + 4 × 1.5, 2EA*

Pump typeImpeller

type

Maximum solids size

[mm]

Maximum number of starts

per hour

Maximum installation depth

[m]

Enclosure class

Insulation class

Maximum liquid temperature [°C]

pH

DWK.H.7.150.750.6 Enclosed 7 6 25 68 F 40 4-10

0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160Q [m³/h]

0

20

40

60

80

100

120

140

160

H[m]

0 5 10 15 20 25 30 35 40 45 Q [l/s]

0

10

20

30

40

50

60[%]Eta

DWK.H.7.150.750.660 Hz

ISO 9906:2012 3B

QH

Eta 2

Eta 1

0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160Q [m³/h]

30

40

50

60

70

80

90

P[kW]

QP2QP1

Page 81: DWK pumps - api.grundfos.com

Pe

rfo

rma

nc

e c

urv

es

an

d t

ec

hn

ica

l d

ata

10

DWK.H.7.150.900.6

Electrical data

DWK.H.7.150.900.6.1D - 3 × 380-415 V

DWK.H.7.150.900.6.1E - 3 × 220-240 V

Pump data

TM06

990

2 35

17

P1 P2 min-1 Starting

method

IN Istart [A] ηmotor [%] Cos φ Moment of inertia [kgm2]

Break down torque [N-m]

Cable [mm2]

[kW] [A] 380 V 400 V 415 V 1/2 3/4 1/1 1/2 3/4 1/1 [power-sensor-ground]

98.9 90 3450 Y/D 172 974 816 781 86 88 89 0.76 0.84 0.87 2.70 597 3 × 50 + 1× 35 + 4 × 1.5*

P1 P2 min-1 Starting

method

IN Istart [A] ηmotor [%] Cos φ Moment of inertia [kgm2]

Break down torque [N-m]

Cable [mm2]

[kW] [A] 220 V 240 V 1/2 3/4 1/1 1/2 3/4 1/1 [power-sensor-ground]

98.9 90 3450 Y/D 298 427 405 87 84 76 0.88 0.90 0.91 2.85 723 6 × 50 + 4 × 1.5 + 1 × 35

Pump typeImpeller

type

Maximum solids size

[mm]

Maximum number of starts

per hour

Maximum installation depth

[m]

Enclosure class

Insulation class

Maximum liquid temperature [°C]

pH

DWK.H.7.150.900.6 Enclosed 7 6 25 68 F 40 4-10

0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 Q [m³/h]

0

20

40

60

80

100

120

140

160

180

H[m]

0 5 10 15 20 25 30 35 40 45 Q [l/s]

0

10

20

30

40

50

60[%]Eta

DWK.H.7.150.900.660 Hz

ISO 9906:2012 3B

QH

Eta 2

Eta 1

0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 Q [m³/h]

40

50

60

70

80

90

100

P[kW]

QP2QP1

81

Page 82: DWK pumps - api.grundfos.com

Dim

en

sio

ns

an

d w

eig

hts

82

DWK pumps11

11. Dimensions and weights

All weights are stated with 10 m cable.

DWK.O.6.50/80.xx.6 and DWK.O.10.80.37.6

TM04

414

7 09

09 -

TM04

414

9 09

09

Hose connection Flange connection

Pump typeConnection

type

Dimensions [mm] Weight[kg]A C D DN2 F V1 V2 V3 V4

DWK.O.6.50.075Hose 438 235 110 50 215 398 462 65 202 39

Flange 438 276 110 50 215 398 490 65 202 39

DWK.O.6.50.15Hose 468 235 110 50 215 428 492 65 202 41

Flange 468 276 110 50 215 428 520 65 202 41

DWK.O.6.50.22Hose 448 235 110 50 215 448 512 65 202 45

Flange 448 276 110 50 215 448 540 65 202 45

DWK.O.6.80.15Hose 468 235 110 80 215 428 560 65 202 41

Flange 468 295 110 80 215 428 520 65 202 41

DWK.O.6.80.22Hose 488 235 110 80 215 448 580 65 202 45

Flange 488 276 110 80 215 448 540 65 202 45

DWK.O.10.80.37Hose 697 286 134 80 253 591 691 90 234 81

Flange 697 321 134 80 253 591 731 90 234 81

Page 83: DWK pumps - api.grundfos.com

Dim

en

sio

ns

an

d w

eig

hts

DWK pumps 11

DWK.O.10.100.37.6 and DKW.O.13.xx.xx.6

TM04

699

8 19

15 -

TM04

699

9 19

15

Pump typeConnection

type

Dimensions [mm] Weight[kg]C D DN2 F V1 V2 V3 V4

DWK.O.10.100.37Hose 286 134 100 253 591 711 90 234 81

Flange 340 134 100 253 591 731 90 234 81

DWK.O.13.80.55Hose 358 179 80 333 734 832 116 302 110

Flange 390 179 80 333 734 872 116 302 110

DWK.O.13.100.55Hose 358 179 100 333 734 872 116 302 110

Flange 409 179 100 333 734 852 116 302 110

DWK.O.13.100.75Hose 358 179 100 333 734 852 116 302 156

Flange 409 179 100 333 734 872 116 302 156

DWK.O.13.100.110Hose 358 179 100 333 779 897 116 302 190

Flange 431 179 100 333 779 917 116 302 190

DWK.O.13.100.150Hose 358 179 100 333 779 897 116 302 195

Flange 431 179 100 333 779 917 116 302 195

DWK.O.13.150.75Hose 358 179 150 333 734 893 116 302 156

Flange 434 179 150 333 734 862 116 302 156

DWK.O.13.150.110Hose 358 179 150 333 779 948 116 302 190

Flange 457 179 150 333 779 907 116 302 190

DWK.O.13.150.150Hose 358 179 150 333 779 948 116 302 195

Flange 457 179 150 333 779 907 116 302 195

83

Page 84: DWK pumps - api.grundfos.com

Dim

en

sio

ns

an

d w

eig

hts

84

DWK pumps11

DWK.E

TM04

414

8 19

15 -

TM04

415

0 19

15

Hose connection Flange connection

Pump type Connection typeDimensions [mm] Weight

[kg]C D DN2 F V1 V2 V3 V4

DWK.E.10.100.220Hose 432 235 100 470 1099 1117 183 470 408

Flange 432 235 100 470 1099 1342 183 470 420

DWK.E.10.150.220Hose 432 235 150 470 1099 1232 183 470 417

Flange 432 235 150 470 1099 1342 183 470 427

DWK.E.10.150.300Hose 432 235 150 470 1099 1232 183 470 442

Flange 432 235 150 470 1099 1342 183 470 452

DWK.E.10.150.370Hose 532 306 150 612 1318 1411 220 557 937

Flange 532 306 150 612 1318 1561 220 557 839

DWK.E.10.150.450Hose 532 306 150 612 1318 1411 220 557 846

Flange 532 306 150 612 1318 1561 220 557 858

DWK.E.10.150.550Hose 532 306 150 612 1318 1411 220 557 909

Flange 532 306 150 612 1318 1561 220 557 921

DWK.E.10.200.300Hose 432 235 200 470 1318 1192 183 470 444

Flange 432 235 200 470 1318 1342 183 470 462

DWK.E.10.200.370Hose 532 306 200 612 1318 1411 220 557 839

Flange 532 306 200 612 1318 1561 220 557 841

DWK.E.10.200.450Hose 532 306 200 612 1318 1411 220 557 848

Flange 532 306 200 612 1318 1561 220 557 860

DWK.E.10.200.550Hose 532 306 200 612 1318 1411 220 557 911

Flange 532 306 200 612 1318 1561 220 557 923

DWK.E.10.200.750Hose 532 306 200 612 1418 1511 220 557 961

Flange 532 306 200 612 1418 1661 220 557 973

DWK.E.10.200.900Hose 532 306 200 612 1418 1511 220 557 1016

Flange 532 306 200 612 1418 1661 220 557 1028

Page 85: DWK pumps - api.grundfos.com

Dim

en

sio

ns

an

d w

eig

hts

DWK pumps 11

DWK.H

TM07

054

9 03

18 -

TM07

032

3 48

17

Hose connection Flange connection

E

V4

V1

V1F

V4

V1 V1H

E

DN2DN2

Pump typeDimensions [mm] Weight

[kg]E V1 V1F V1H V4 DN2

DWK.H.7.80.110 36 930 1025 930 330 80 235DWK.H.7.80.150 36 930 1025 930 330 80 250DWK.H.7.100.220 0 1161 1410 1180 470 100 530DWK.H.7.100.300 0 1161 1410 1180 470 100 580DWK.H.7.100.370 10 1350 1595 1445 518 100 800DWK.H.7.150.450 10 1350 1595 1445 518 150 830DWK.H.7.150.550 10 1350 1595 1445 518 150 850DWK.H.7.150.750 10 1450 1695 1545 518 150 880DWK.H.7.150.900 10 1450 1695 1545 518 150 1500

85

Page 86: DWK pumps - api.grundfos.com

Ac

ce

ss

orie

s

86

DWK pumps12

12. Accessories

Pictures Description Dimensions

DWK.O[kW]

DWK.H[kW]

DWK.E, DWK.H[kW] Product

number0.75 1.5 2.2 3.7 5.5 7.5 11 15 11 15 22 30 37 45 55 75 90

TM01

717

3 14

09

Lifting chain 320 kg SS with shackle, DoC, certificate and work instructions

2 m ● ● ● ● ● ● ● ● ● ● 98989662

3 m ● ● ● ● ● ● ● ● ● ● 98989664

4 m ● ● ● ● ● ● ● ● ● ● 98989666

6 m ● ● ● ● ● ● ● ● ● ● 98989668

8 m ● ● ● ● ● ● ● ● ● ● 98989670

10 m ● ● ● ● ● ● ● ● ● ● 98989672

TM01

717

3 14

09

Lifting chain 500 kg SS with shackle, DoC, certificate and work instructions

2 m ● ● 98538174

3 m ● ● 98538175

4 m ● ● 98538176

6 m ● ● 98538177

8 m ● ● 98538178

10 m ● ● 98538179

TM01

717

3 14

09 Lifting chain 2000 kg SS with hook, DoC, certificate and work instructions

4 m ● ● ● ● ● 98425801

6 m ● ● ● ● ● 98425802

8 m ● ● ● ● ● 98425803

10 m ● ● ● ● ● 98425804

Wire with clip, galvanised

3 m ● ● ● ● ● ● ● 96884375

6 m ● ● ● ● ● ● ● 96884374

10 m ● ● ● ● ● ● ● 96884373

TM07

009

1 41

17

Outlet flange with O-ring and bolts

DIN

DN 50(1) ● ● ● 96922567

DN 80(1) ● ● 96922568● ● 96922569

DN 100(1) ● ● ● ● ● 96922570

DN 150(1) ● ● ● 96922571

Outlet flange with gasket and bolts

DN 80(1) ● ● 99878884

DN 100(1) ● ● 96922572

DN 100(1) ● 99878942

DN 150(1) ● ● 96922573● ● ● ● ● 96922574

DN 200(2) ❍ 96922576

❍ ❍ ● ● ● 96922577

TM07

009

1 41

17

Outlet flange with O-ring and bolts

JIS

DN 50(1) ● ● ● 96922555

DN 80(1) ● ● 96922556● ● 96922557

DN 100(1) ● ● ● ● ● 96922558

DN 150(1) ● ● ● 96922559

Outlet flange with gasket and bolts

DN 80(1) ● ● 99878886

DN 100(1) ● ● 96922560● 99878955

DN 150(1) ● ● 96922561● ● ● ● ● 96922562

DN 200(2) ❍ 96922564

❍ ❍ ● ● ● 96922565(1) DIN flanges up to DN 150 are according to DIN 2633 PN10/PN16.(2) DIN flanges DN 200 and up are according to DIN 2362.

● available for stated product range❍ available only for DWK.E* for the Chinese market, available upon request

Page 87: DWK pumps - api.grundfos.com

Ac

ce

ss

ori

es

DWK pumps 12

TM07

009

1 41

17

Outlet flange with O-ring and bolts

AN

SI1

NPS 2" ● ● ● 96922579

NPS 3"● ● 96922580

● ● 96922581NPS 4" ● ● ● ● ● 96922582NPS 6" ● ● ● 96922583

Outlet flange with gasket and bolts

NPS 3" ● ● 99878885

NPS 4"● ● 96922584

● 99878954

NPS 6"● ● 96922585

● ● ● ● ● 96922586

NPS 8" ❍ 96922588

❍ ❍ ● ● ● 969225891 ANSI flanges according to ASME b 16.5 #150 lbs.

TM07

009

2 41

17

Outlet for hose with gasket and bolts

DN 50 ● ● ● 96922591

DN 80● ● 96922592

● ● 96922593● ● 99776560

DN 100

● ● ● ● ● 96922594● ● ● 96922595

● ● 96922596● 99878887

DN 150● ● 96922597

● ● ● ● ● 96922598

DN 200 ❍ 96922600

❍ ❍ ● ● ● 96922601

TM07

009

3 41

17

Steel.Outlet flange with bolts and nuts.

DIN

DN 80 ● ●

Contact Grundfos

DN 100 ● ● ●DN 150 ● ● ● ●

KS

DN 80 ● ●DN 100 ● ● ●DN 150 ● ● ● ●

AN

SI NPS 3" ● ●

NPS 4" ● ● ●NPS 6" ● ● ● ●

TM07

210

4 07

20 LC 231 ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ●Contact

Grundfos

TM07

213

9 07

20 LC 241 ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ●Contact

Grundfos

TM06

895

0 14

17

GU01 monitoring system* ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● 96922603

Pictures Description Dimensions

DWK.O[kW]

DWK.H[kW]

DWK.E, DWK.H[kW] Product

number0.75 1.5 2.2 3.7 5.5 7.5 11 15 11 15 22 30 37 45 55 75 90

87

● available for stated product range❍ available only for DWK.E* for the Chinese market, available upon request

Page 88: DWK pumps - api.grundfos.com

Ac

ce

ss

orie

s

88

DWK pumps12

● available for stated product range❍ available only for DWK.E* for the Chinese market, available upon request

TM06

895

1 14

17 GU02 monitoring system ● ● ● ● ● ● ● ● ● ● ● ● ● ● 96922604

TM07

009

4 41

17 Stainless steel (304).Wire with shackle.

3 m ● ● ● ● ● ● ● ● ●

Contact Grundfos

4 m ● ● ● ● ● ● ● ● ●

6 m ● ● ● ● ● ● ● ● ●

8 m ● ● ● ● ● ● ● ● ●

10 m ● ● ● ● ● ● ● ● ●

TM01

698

2 39

99

Float switch

2 m cable ● ● ● ● ● ● ● ● ● ● ● ● ●

Contact Grundfos

4 m cable ● ● ● ● ● ● ● ● ● ● ● ● ●

6 m cable ● ● ● ● ● ● ● ● ● ● ● ● ●

10 m cable ● ● ● ● ● ● ● ● ● ● ● ● ●

TM07

009

6 41

17

Bracket for float switch

Flange JIS 10K 100A ● ● ● ● ● ● ● ● ● ● ● ● ● Contact

Grundfos

Pictures Description Dimensions

DWK.O[kW]

DWK.H[kW]

DWK.E, DWK.H[kW] Product

number0.75 1.5 2.2 3.7 5.5 7.5 11 15 11 15 22 30 37 45 55 75 90

Page 89: DWK pumps - api.grundfos.com

Gru

nd

fos

Pro

du

ct

Ce

nte

r

89

DWK pumps 13

13. Grundfos Product Center

Online search and sizing tool to help you make the right choice.http://product-selection.grundfos.com

All the information you need in one place

Performance curves, technical specifications, pictures, dimensional drawings, motor curves, wiring diagrams, spare parts, service kits, 3D drawings, documents, system parts. The Product Center displays any recent and saved items - including complete projects - right on the main page.

Downloads

On the product pages, you can download installation and operating instructions, data booklets, service instructions, etc. in PDF format.

TM07

238

4TM

07 2

383

1

2 3 4 5

Pos. Description

1 This drop-down menu enables you to set the search function to "Products" or "Literature".2 SIZING enables you to size a pump based on entered data and selection choices.3 CATALOGUE gives you access to the Grundfos product catalogue.

4

REPLACEMENT enables you to find a replacement product.Search results will include information onthe lowest purchase pricethe lowest energy consumptionthe lowest total life cycle cost.

5 LIQUIDS enables you to find pumps designed for aggressive, flammable or other special liquids.

Page 90: DWK pumps - api.grundfos.com

GRUNDFOS A/S DK-8850 Bjerringbro . DenmarkTelephone: +45 87 50 14 00www.grundfos.com

99888642 06.2020

ECM: 1276063 Trad

emar

ks d

ispl

ayed

in th

is m

ater

ial,

incl

udin

g bu

t not

lim

ited

to G

rund

fos,

the

Gru

ndfo

s lo

go a

nd “b

e th

ink

inno

vate

” are

regi

ster

ed tr

adem

arks

ow

ned

by T

he G

rund

fos

Gro

up. A

ll rig

hts

rese

rved

202

0 G

rund

fos

Hol

ding

A/S

, all

right

s re

serv

ed.


Recommended