Page 20 DW138 issue 2 MODELS: DX302SJ*00, DX302WJ*00 CIRCUIT DIAGRAM DX302SJ*01, DX302WJ*01 0165 400 714 DX302SJ*02, DX302WJ*02 IMPORTANT SAFETY NOTICE This diagram has been prepared for use by electrically qualified service technicians. The manufacturer cannot be held responsible for the interpretation of its service publications nor for any injury or damage that may occur in connection with their use. NOTE:- Regen. Valve & Turbidity sensing not used on these models
Transcript
Page 1: DX302wJ wiring.pdf

Page 20 DW138 issue 2

MODELS: DX302SJ*00, DX302WJ*00 CIRCUIT DIAGRAMDX302SJ*01, DX302WJ*01 0165 400 714

DX302SJ*02, DX302WJ*02

IMPORTANT SAFETY NOTICEThis diagram has been prepared for use by electrically qualified service technicians. Themanufacturer cannot be held responsible for the interpretation of its service publications nor forany injury or damage that may occur in connection with their use.

NOTE:- Regen. Valve & Turbidity

sensing not used on these models

Page 2: DX302wJ wiring.pdf

Page 21 DW138 issue 2

Control Panel Layout

Turn Child-Lock Off

OPERATION ITEM INPUT OUTPUT

Check Child-Lock Switch dishwasher on by pressing ‘POWER’

button. Press any button

If Display shows ‘CL’, the Child-Lock is on. Continue the following steps to

turn the Child-Lock off

If Display doesn’t show ‘CL’, the Child-Lock is off. Skip the following steps

and go to ‘Fault Recall & Output Test’

Bypass Child-Lock Press & hold any button for 5sec Buzzer beeps 2 sec, ‘CL’ disappears in Display. Child-Lock is bypassed

Cancel Wash Program

(if running)

Press & hold ‘PROGRAM/CLEAR’ button

for 3 secAll program LEDs on, wash program cancelled

Turn off Child-LockPress & hold ‘PROGRAM/CLEAR’ button

for 5 sec

Buzzer beeps 2 sec, all LEDs off, Display shows ‘CL’ for 4 sec. Child-Lock

is turned off

Note:

1. The Child-Lock must be turned off before entering ‘Fault Recall & Output Test’

2. The Child-Lock can only be turned off when there is no wash program running

3. The Child-Lock must be bypassed before it is turned off

Fault Recall & Output Test

OPERATION ITEM INPUT OUTPUT

Enter Test ModeSwitch dishwasher off by pressing the ‘POWER’

buttonAll off

Press & hold ‘PROGRAM/CLEAR’ button &

‘START/PAUSE’ button then switch power on.

Keep holding the 2 buttons for 2 sec.

‘RINSE/HOLD’ LED flashing, Display show '1C'

Select F/O Test Press ‘PROGRAM/CLEAR’ button ‘QUICK30’ LED flashing, Display shows '2C'

Enter F/O Test Press ‘START/PAUSE’ button‘QUICK30’ LED on. LED ‘READY’ flashing, Display & buzzer showing

the last occurred fault, (see ‘Fault Indication’ table Page 14)

Press ‘PROGRAM/CLEAR’ button Display & buzzer showing the 2nd

last occurred fault

Press ‘PROGRAM/CLEAR’ button Display & buzzer showing the 3rd

last occurred fault

Press ‘PROGRAM/CLEAR’ button‘REGULAR Eco’ LED on. Display shows ‘4’. Buzzer beeps 4 times.

Regeneration valve open (see ‘Output Indication’ table for details Page 14)

Press ‘PROGRAM/CLEAR’ button Display shows ‘5’, buzzer beeps 5 times. Drain pump on

Press ‘PROGRAM/CLEAR’ buttonDisplay shows ‘6’, buzzer beeps 6 times. Inlet valve open (only when level

is not detected)

Press ‘PROGRAM/CLEAR’ buttonDisplay shows ‘7’, buzzer beeps 7 times. Heater on (only when level is

detected)

Press ‘PROGRAM/CLEAR’ button Display shows ‘8’, buzzer beeps 8 times. Recirculation pump on

Press ‘PROGRAM/CLEAR’ buttonDisplay shows ‘9’, buzzer beeps 9 times. Detergent dispenser open

(dispenser may open up to 20 seconds later)

Press ‘PROGRAM/CLEAR’ button Display shows ‘10’, buzzer beeps 10 times. Drying fan on

Press ‘PROGRAM/CLEAR’ button ‘QUICK30’ LED on. Display & buzzer showing the last occurred fault

Press ‘PROGRAM/CLEAR’ button Repeat

Exit F/O Test Switch off

Page 3: DX302wJ wiring.pdf

Page 22 DW138 issue 2

Fault Indication

FAULT NAME DISPLAY CUSTOMER CAN SEE SHORT EXPLANATION WHAT HAPPENS?

No Fault 'i 0' --

Not Filling 'i10' YesPressure switch is not set after 60 secs of

fillingProgram stops

Not Draining 'i20' YesPressure switch is not reset after 120 secs of

drainingProgram stops

Flood Control 'i30' Yes Inlet valve fault or 2nd

pressure switch is set Program stops

Recirculation Pump

Triac Short Circuit'i50' Yes

Tacho signals are detected while recirculation

pump is not onProgram stops

Not Heating 'i60' NoTemperature rise <1.5

oC within 3 minutes

during heatingProgram continues without heating

NTC Fault 'i70' No NTC short or open circuit Program continues without heating

EEPROM Fault 'i80' NoCommunication error with external

EEPROM

MCF/CCF Check

Sum Fault'i90' No

Check sum MCF or CCF is not right. Only

detected after switching on.

(Program software not working)

Program selection not possible

Turbidity Sensor

Fault'ib0' No

Turbidity signal required for calibration not

reached in 15 sec

Program continues with maximum turbidity

response

Tacho Fault 'id0' NoNo tacho signal detected when recirculation

pump is on

Program continues. Recirculation pump

without speed control. No heating

Filling Time Fault 'iF0' No Filling timeout Program continues with less water

Output Indication

TESTED ACTUATOR DISPLAY BUZZER BEEPS COMMENT

Regeneration Valve ‘4’ 4 times Not available on this model

Drain pump '5' 5 times

Inlet valve ‘6’ 6 times Only when pressure switch is not set

Heater ‘7’ 7 times Only when pressure switch is set

Recirculation pump ‘8’ 8 times

Detergent dispenser ‘9’ 9 times

Drying fan ‘10’ 10 times

Boost Dry Option

OPERATION ITEM INPUT OUTPUT

Select “REGULAR

Eco” program

Turn Child-Lock off, cancel program if running,

select "REGULAR Eco" program

"REGULAR Eco" LED on, "Wash", "Rinse" & "Fan Dry" LED flashing,

Display shows the program time (98 + 5 min)

Turn on ‘Boost Dry’ simultaneously press " PROGRAM/CLEAR "

button & "DELAY" button

The program time shown in Display increases 10 – 15 min. Boost Dry

option is turned on.

Note:

1. This option can be turned on when the customer complains about the dry performance.

2. Turning on the option will raise the temperature and extend the wash time in the final rinse. Therefore, the selected

wash program will be longer.

3. This option cannot be applied to ‘RINSE/HOLD’ & ‘QUICK30’ program.

4. Once turned on, the option will stay on until it’s turned off.

5. Repeat the above operation will turn off the option, while the program time shown in Display decreases 10 – 15 min.

Page 4: DX302wJ wiring.pdf

Page 23 DW138 issue 2

SPECIFICATIONS

MOTORRecirc.

Drain Motor

Part Nº 0214 477 03750 wattWinding resistance:– White - Blue 40 ohm White – Red 130 ohmPart Nº 0214 400 030 26 watt, 220/240 volt.Winding resistance 200 ohm ± 10%

Note:- Recirc. and Drain Motor has auto-reset overload and mayrestart without warning

CAPACITORPart Nº 0588 400 0183 µF; 400/450/500 Volt

ELEMENT

Part Nº 0122 400 0122100 watt – 8.75 amp – 25 ohmThe Thermal Over-load opens at 92ºC and automatically resets when thetemperature drops.Water temperature is raised 2ºC per minute (Full load)

TEMPERATURESENSOR

Part Nº 0534 400 087, Switch N.T.C. without Turbidity Sensor.Temperature Resistance

10ºC 9653 Ohm25ºC 4843 Ohm60ºC 1204 Ohm90ºC 445 Ohm

WASH PROGRAM OVERVIEW

Variable

DetectedWash Rinse

ProgramLoad Pre-wash Main Wash Rinse 1 Rinse 2 Hot Rinse

DryTotal

Time

55oC 68 oC <65 oC <65 oC 68 oCIntensive

70 o

30min 36min 7min 7min 19min 24min

123min

60 oC 68 oC

Half

9min 40min 8min 21min 24min

68 oC 68 oC

Regular

65o

Full

9min 40min 8min 21min 24min

102min

<37 oC <45 oCRegular

Eco 37min 33min 18min 10min

98min

<65 oC <67 oC

Quick3017min 13min

30min

Rinse /

Hold12min

Page 5: DX302wJ wiring.pdf

Page 24 DW138 issue 2

COMPONENTS CONNECTIONS SPEC. VALUE NOTES

N (note 1)

↔ A2 0 ΩPower Cable &

ON/OFF ButtonL

(note 1) ↔ B1 0 Ω

With ON/OFF

button pressed

Heater A1 ↔ C5 25 Ω

InfiniteWater level not

reachedPressure Switch B1 ↔ C5

0 Ω Water level reached

InfiniteSafety water level

not reached2

nd Pressure Switch C1 ↔ A2

0 ΩSafety water level

reached

0 Ω With door closedDoor Switch B2 ↔ D1

Infinite With door opened

Dispenser D5 ↔ D7 1.5k Ω

6.03k Ω At 20oC

(note 2)Temperature

Sensor (NTC)G5 ↔ G6

1.01k Ω At 65oC

Tachometer E1 ↔ E2 210 Ω

Fan Motor D1 ↔ D3 7.75k Ω

Inlet Valve &

Flood SwitchD1 ↔ D7 2k Ω

C11 ↔ C3 40 Ω Main winding

Wash Motor Measured on motor

(Blue ↔ White)130 Ω Auxiliary winding

Drain Motor C11 ↔ C1 200 Ω

Note 1: Measurement points ‘L’ and ‘N’ refer to the pins of the plug fitted to the power cable.

Note 2: The resistance of the thermistor varies in different temperatures. Refer Page 15 for more

readings.

COMPONENT RESISTANCE and MEASUREMENT

G E D CB A

8 7 6 5 2 1 7 5 3 1 11 7 5 3 1 2 1 1 2


Recommended