4
Transcript
Page 1: DYNAMIC POWER CURVE - Goldwind 4.0… · Goldwind Americas Chicago Headquarters 20 N Wacker Drive, Suite 1375 Chicago, IL 60606 USA Goldwind Americas T: +1 (312) 948-8050 E: info@goldwindamericas.com
Page 2: DYNAMIC POWER CURVE - Goldwind 4.0… · Goldwind Americas Chicago Headquarters 20 N Wacker Drive, Suite 1375 Chicago, IL 60606 USA Goldwind Americas T: +1 (312) 948-8050 E: info@goldwindamericas.com
Page 3: DYNAMIC POWER CURVE - Goldwind 4.0… · Goldwind Americas Chicago Headquarters 20 N Wacker Drive, Suite 1375 Chicago, IL 60606 USA Goldwind Americas T: +1 (312) 948-8050 E: info@goldwindamericas.com

DYNAMIC POWER CURVE

Air Density:1.225kg/

··-·-··-··-·-··-·-··-·-··-·-··-··--�- --------

1000

i)

l5

GN 136/42([)

� -·-··-·· -· -. ·- .. -. ·-·-··-·-·. -. -. ·-··-·-·· -. -. ·-··-·-·· -· -.. -·-·· -. ·-·-··-· -·.

I)

0 l(Ji 15

TECHNrCAL SPECIFICATIONS

GW 4SMW

Item Unit Configuration Platform GW4S

Models GW 136/ 4.0MW GW 136/ 4.2 MW

Operation Parameters

Rated Power kW 4000 and 4200

Wind Class IEC IIA

Cut-in Wind Speed mis 2.5

Rated Wind Speed mis 1 1

Cut-out Wind Speed mis 25

Designed Operating Life Years ::020

Operating Temperature Range ·c -20-40

Survival Temperature Range ·c -30-50

Rotor

Rotor Diameter m

Swept Area m"2

Generator

Type

Converter I Type

Full Power Converter (IGBT) Modular System

Power Factor Regulation Range 1/4 Rated Power

2/4 Rated Power

3/4 Rated Power

Rated Power

Rated Frequency Range Hz

Rated Output Power KVA

Rated Output Voltage V

Braking System

Aerodynamic Brake System

Mechanical Brake System

Yaw System I Type/Design

Control System and Lightning Protection

Type

Lightning Protection Design Standard

Lightning Protection Strategy

Wind Turbine Ground Resistance 0

Tower

Type

Hub Height m

Weight

Rotor t

Nacelle t

Generator t

136

14711

Permanent Magnet Direct Drive Synchrono-us Generator

Capactive 0.9 to Inductive 0.9

Capactive 0.9 to Inductive 0.9

Capactive 0.9 to Inductive 0.9

Capactive 0.9 to Inductive 0.9

50/60Hz

4889

690 (Inverted Output Voltage)

Blade Pitch Triple-Redundant

Hydraulic Mechanical Brake System

(for Maintenance)

Motor Drive/ Four Planetary Stages for Speed Reduction

PLC Control System

Complying with IEC 61400-24-2010, IEC

62305-2006, and in Conformance with GL

Standards

Electrical lightning protection, tip lightning

protection (in Conformance with GL

Standards)

::,;4

Conical Steel Tower

100 , 11 O

95.3

40

95

Page 4: DYNAMIC POWER CURVE - Goldwind 4.0… · Goldwind Americas Chicago Headquarters 20 N Wacker Drive, Suite 1375 Chicago, IL 60606 USA Goldwind Americas T: +1 (312) 948-8050 E: info@goldwindamericas.com

Goldwind Americas

Chicago Headquarters20 N Wacker Drive, Suite 1375 Chicago, IL 60606 USA

Goldwind AmericasT: +1 (312) 948-8050E: [email protected] W: goldwindamericas.com