Multifunction Pressure and Temperature ATEX Calibrators
MAXi ATEX Calibration Lab 3000CAL
www.eigroup.biz
ATEX Multifunction Calibrators- Thermocouple- Resistance Thermometers- mA Loop with power supply- V, mV, Hz, Ohm
Pneumatic Pressure Calibratorwith built-in pump vacuum to 40 Bar
Hydraulic Pressure Calibratorwith built-in pumpup to 700 Bar
Low pressure Calibratorwith built-in pump 160mBar
Absolute Pressure Sensor 2 Bar
HART Programmer
Certificate of calibration
E instruments
The Atex Calibration laboratory includes all the instruments necessary for calibration on Intrinsically Safe
Area. Multifunction calibrators with simultaneous dual channel for thermocouple, resistance thermometers,
mA, V and Frequency. Pressure calibrators from low 160mBar up to Hydraulic 1000 Bar. A fundamental tool
for Oil&Gas and Petrolchemical Plant. Splash proof carrying cases will protect instruments during transport
and stocking
Features are related to all models equipped with full configuration. On next pages you can find specific details.
MAXiCALProcess Multifunction Calibrators
MAXi ATEX Calibration Lab 3000Multifunction Pressure and Temperature ATEX Calibrators
CAL
26
Speci
ficatio
ns
may
change w
ithout notic
e
MAXiCALProcess Multifunction Calibrators
Technical data:
Maximum Voltage: 30 V
Storage temperature:Operating temperature:
-40°C to 71°C 10°C to 55°C
Relative humidity: 90 % (10 to30°C); 75 % (30 to 40°C);45 % (40 to 50°C); 35 % (50 to 55°C)
Dimensions (HxWxD): 200 x 96 x 47 mm
Weight: 650 g
Power supply: 4x AA, type approved
Operating time: 25 hours typical
Intrinsically-Safe Multifunction Process Calibrator
Simply powerful intrinsically-safe calibration tool
Standard delivery:• Atex Calibrator• Test leads• Test clips• one pair of stackable test leads• ISO Traceable calibration certifcate• batteries
• instruction manual
• Power transmitters with internal loop
supply
• Store frequently-used test setups for
later use
-The multifunction IS calibrator is able to calibrate almost any process instrument likely to need service in an ex-hazardous area. The device is a powerful, multifunction
calibration solution that offers:• Measure volts dc, mA, RTDs, thermo- couples, frequency and ohms
• Source or simulate volts dc, mA, RTDs, thermocouples,frequency and ohms
• Two channel simultaneous source and measure capability for calibration of
transmitters
Ex-data:Ex-designation: II 1 G EEx ia IIB 171°C
EC-Certificate of conformity:Kema 04 ATEX 1303 X
I.S. Class 1 Div. 1 Groups B-D, 171°C
Summary Specifcations: (18°C to 28°C for one year)
Function Measure or Source Range Resolution Accuracy Notes
Voltage 0 to 100 mV0 to 10 V (Source)0 to 30 V (Measure)
0.01 mV0.001 V0.001 V
0.02 % Rdg + 2 digits Max. Load 1 mA
mA 0 to 24 0.001 mA 0.02 % Rdg + 2 digits Max. Load 500 Ω @ 20 mA
mV (TC terminals) -10.00 mV to +75.00 mV 0.01 mV ± (0.025 % or range + 1 digits)
Resistance 15 Ω to 3200 Ω (Source)0 Ω to 3200 Ω (Measure)
0.1 Ω to 1 Ω0.1 Ω to 1 Ω
0.10 Ω to 1.0 Ω0.10 Ω to 1.0 Ω
Frequency 2.0 to 1000.0 CPM1 to 1000 Hz1 to 10.0 kHz
0.1 CPM1 Hz0.1 kHz
± (0.05 % + 1 digit)± (0.05 % + 1 digit)± (0.05 - 0.25 % + 1 digit)
For frequency source wave-form is 5 V p-p squarewave, -0.1 V offset
Loop supply 12 V N/A 10 %
Temperature coeffcient: -10°C to 18°C, 28°C to 55°C, ±0.005% of range per °C
Thermocouple accuracy specifcations:
Thermocouple Measure or source
J -200 to 0°C0 to 1200°C
1.0°C0.7°C
K -200 to 0°C0 to 1370°C
1.2°C0.8°C
T -200 to 0°C0 to 400°C
1.2°C0.8°C
E -200 to 0°C0 to 950°C
0.9°C0.7°C
R-20 to 0°C0 to 500°C
500 to 1750°C
2.5°C1.8°C1.4°C
S-20 to 0°C0 to 500°C
500 to 1750°C
2.5°C1.8°C1.5°C
B600 to 800°C
800 to 1000°C1000 to 1800°C
2.2°C1.8°C1.4°C
L-200 to 0°C0 to 900°C
0.85°C0.7°C
U-200 to 0°C0 to 400°C
1.1°C0.75°C
N200 to 0°C
0 to 1300°C1.5°C0.9°C
Resolution
J, K, T, E, L, N, UB, R, S
0.1°C, 0.1°F1°C, 1°F
Notes
Accuracy specifcations include 0.2°C cold junction uncertainty.
Thermocouple accuracy specifcations:
RTD Type Range
Accuracy
Measure (4 wire) Source
Ni 120 -80°C to 260°C 0.2°C 0.2°C
Pt 100 - 385 -200°C to 800°C 0.33°C 0.33°C
Pt 100 - 3926 -200°C to 630°C 0.3°C 0.3°C
Pt 100 - 3916 -200°C to 630°C 0.3°C 0.3°C
Pt 200 - 385-200°C to 250°C250°C to 630°C
0.2°C0.8°C
0.2°C0.8°C
Pt 500 - 385-200°C to 500°C500°C to 630°C
0.3°C0.4°C
0.3°C0.4°C
Pt 1000 - 385-200°C to 100°C100°C to 630°C
0.2°C0.2°C
0.2°C0.2°C
Resolution
RTD 0.1°C, 0.1°F
Features:
Simultaneous Function Capability Channel A Channel B
24.000 mA DC M M or S
24.000 mA DC with loop supply M
100.00 mV DC M or S
30.000 V DC Measure M
20.000 V DC Measure10.000 V DC Source
M or S
Source: 15 to 3200 Ω, Measure: 0 to 3200 Ω M or S
Thermocouple J, K, E, R, S, B, L, U, N M or S
RTD Ni120; Pt100 (392); Pt100 (JIS); Pt100, 200, 500,1000 (385)
M or S
M or SFrequency; Squarewave, 1 CPM to 10 kHz; fxed amplitude 5V p-p
M = Measure S = Source / Simulate
26
Speci
ficatio
ns
may
change w
ithout
notic
e
MAXiCALProcess Multifunction Calibrators
MAXi ATEX Calibration Lab 3000Multifunction Pressure and Temperature ATEX Calibrators
CAL
OVERVIEW
With advanced microprocessor technology and state-of-the-art
silicon pressure sensors, the ConST211 series digital pressure
gauges provide an accurate, reliable, and economic solution for
wide range of pressure applications. They are loaded with
functionality and remarkably easy to use. To reach the best
performance, every silicon pressure sensor in gauges has been
special ly aged, tested and screened before assembly.
ConST211 series digital pressure gauges are unmatched in
performance and reliability. Best of all, they are surprisingly
affordable.
FEATURES
APPLICATIONS
Precision pressure measurement
Field gauge calibration
Pressure safety valve (PSV) testing
Pressure regulator testing
SPECIFICATIONS
Model
ConST 211: Regular gauge
ConST 211 IS: ATEX certified intrinsically safe
Accuracy
ConST 211(IS)-02: 0.025% of full scale
ConST 211(IS)-05: 0.05% of full scale
ConST 211(IS)-10: 0.1% of full scale
ConST 211(IS)-20: 0.2% of full scale
(For detail accuracy, please see pressure range table)
Gauge types
Gauge pressure
Compound Pressure
Absolute pressure
Differential pressure
Pressure Ranges
·
·0.05% full scale accuracy (ConST 211-05)
·0.1% full scale accuracy (ConST 211-10)
·0.2% full scale accuracy (ConST 211-20)
·Pressure ranges to 36,000 psi (2500 bar)
·Fully temperature compensated accuracy from 14°F to 122°F
(-10°C to 50°C)
·Up to eleven selectable pressure units
·Large, easy to read display with 5-digit resolution
·Back lighted display
·% pressure indication with fan-shaped graph scale for visual
reference
·Display flash warning when pressure over 120% of FS
·ATEX certified intrinsically safe (Model CONST 211 IS)
·NIM traceable calibration certificate (optional)
·9V battery power or AC adapter (optional)
0.025% full scale accuracy (ConST 211-02)
[1]Gauge Pressure
P/N
V15
GP2
GP5
GP10
GP15
GP30
GP50
GP100
GP300
GP500
GP1K
GP3K
GP5K
GP10K
GP15K
GP25K
GP30K
GP36K
Pressure
Range
(psi)
-15
2
5
10
15
30
50
100
300
500
1000
3000
5000
10000
15000
25000
30000
36000
Pressure
Range
(bar)
-1.0
0.16
0.35
0.7
1.0
2.0
3.5
7.0
20
35
70
200
350
700
1000
1600
2000
2500
[2]Media
G
G
G
G [3]
G , L [3]G , L
G , L
G , L
G , L
G , L
G , L
G , L
G , L
G , L
G , L
G , L
G , L
G , L
Accuracy
(% FS)
0.025 (0.05, 0.1, 0.2)
0.05 (0.1, 0.2)
0.025 (0.05, 0.1, 0.2)
0.025 (0.05, 0.1, 0.2)
0.025 (0.05, 0.1, 0.2)
0.025 (0.05, 0.1, 0.2)
0.025 (0.05, 0.1, 0.2)
0.025 (0.05, 0.1, 0.2)
0.025 (0.05, 0.1, 0.2)
0.025 (0.05, 0.1, 0.2)
0.025 (0.05, 0.1, 0.2)
0.025 (0.05, 0.1, 0.2)
0.025 (0.05, 0.1, 0.2)
0.025 (0.05, 0.1, 0.2)
0.1 (0.2)
0.1 (0.2)
0.1 (0.2)
0.1 (0.2)
Burst
Pressure
3 X
3 X
3 X
3 X
3 X
3 X
3 X
3 X
3 X
3 X
3 X
3 X
3 X
2 X
2 X
1.5 X
1.5 X
1.5 X
Note:
[1]. Sealed gauge pressure for above 1000 psi
[2]. G=Gas, L=Liquid
[3]. 0.025% FS for gas media only
EX II 1 G Ex ia IIC T4 Ga
Permitted for Zone0,Equipment Group II,Gas Group IIC hazardous atmospheres,temperature class T4
This product conforms to the following standards:
EN 60079-0: 2009
EN 60079-11: 2007
26
Speci
ficatio
ns
may
change w
ithout
notic
e
MAXiCALProcess Multifunction Calibrators
MAXi ATEX Calibration Lab 3000Multifunction Pressure and Temperature ATEX Calibrators
CAL
Absolute Pressure
P/N
AP5
AP10
AP15
AP30
AP50
AP100
AP300
AP500
AP1K
AP3K
AP5K
P/N
DP1
DP2
DP5
DP10
DP20
DP30
P/N
CP2
CP5
CP10
CP15
CP30
Pressure
Range
(psi)
5
10
15
30
50
100
300
500
1000
3000
5000
Pressure
Range
(inH O)2
1
2
5
10
20
30
Pressure
Range
(psi)
±2
±5
±10
±15
-15 to 30
Pressure
Range
(bar)
0.35
0.7
1.0
2.0
3.5
7.0
20
35
70
200
350
Pressure
Range
(mbar)
2.5
5.0
10
25
50
100
Pressure
Range
(bar)
±0.16
±0.35
±0.7
±1
-1 to 2
Media
G
G
G
G
G
G , L
G , L
G , L
G , L
G , L
G , L
Media
G
G
G
G
G
G
Media
G
G
G
G
G
Accuracy
(% FS)
0.1 (0.2)
0.1 (0.2)
0.1 (0.2)
0.1 (0.2)
0.1 (0.2)
0.1 (0.2)
0.1 (0.2)
0.1 (0.2)
0.1 (0.2)
0.1 (0.2)
0.1 (0.2)
Accuracy
(% FS)
0.4
0.2
0.1
0.1
0.05
0.05
Accuracy
(%FS)
0.05 (0.1, 0.2)
0.025(0.05,0.1,0.2)
0.025(0.05,0.1,0.2)
0.025(0.05,0.1,0.2)
0.025(0.05,0.1,0.2)
Burst
Pressure
3 X
3 X
3 X
3 X
3 X
3 X
3 X
3 X
3 X
3 X
3 X
Burst
Pressure
100 X
100 X
50 X
20 X
20 X
20 X
Burst
Pressure
3X
3X
3X
3X
3X
Differential Pressure
Compound Pressure
(0–30) psi: Clean dry non-corrosive gases
(50–36,000) psi: media compatible with 316L SS
Pressure Port
NPT(≤15,000psi)
Autoclave F-250-C, 9/16" - 18 UNF female or Autoclave M-250-C,
9/16"-18 UNF male (>15,000psi)
0.156 inch (4mm) test hose (for differential pressure)
Other connections available per request
Power
Battery: One 9V alkaline battery (included)
Battery life: 300 hours (10 readings/s), 600 hours (3 reading/s), or
6000 hours (1 reading/10s)
Power auto-off: 60 minutes power auto-off. Auto-off may be disable
External power: 110/220V external power adapter (optional)
(Do not use the external power adapter in a hazardous atmosphere)
Enclosure
Case material: Aluminum alloy
Wetted parts: 316L SS
Dimension: 120mm diameter X 40mm depth
Weight: 0.6kg
Intrinsic Safety and European Compliance
CE marked
ATEX certified intrinsically safe (ConST 211IS)
Communication
RS232 (Do not use the RS-232 connector in a hazardous
atmosphere)
Media Compatibility
Description: 5 full digit FSTN LCD
Display rate: 3 readings per second (Default setting)
Adjustable from 10 readings per second to 1 reading every ten
seconds
Numeral display height: 16.5mm (0.65”)
Fan-shaped Graph Scale
Similar to analog dial, including pressure swing, % indication with
fan-shaped graph scale for visual reference, low/high alarm
Pressure Units2Pa, kPa, MPa, psi, bar, mbar, kgf/cm , inH O, mmH O, inHg, mmHg2 2
Environmental
Compensated Temperature: 14°F to 122°F (-10°C to 50°C)
Operating Temperature*: 14°F to 122°F (-10°C to 50°C)
*0.025%FS accuracy guaranteed only over the ambient temperature
range of 68°F to 79°F (20°C to 26°C)
Storage Temperature: -4°F to 158°F (-20°C to 70°C)
Humidity: <95%
Display
1 4,,
26
Speci
ficatio
ns
may
change w
ithout notic
e
MAXiCALProcess Multifunction Calibrators
MAXi ATEX Calibration Lab 3000Multifunction Pressure and Temperature ATEX Calibrators
CAL
Specification are based on minimum volume
PGS-700/PGS-1000 PGS-40
Features PGS-7 PGS-40 PGS-700 PGS-1000
Pneumatic pressure capability • •Vacuum capability • •Hydraulic capability • •Integral fine control for accurate set point • • • •adjustable stroke for over pressure safety •Controlled pressure relief valve • • • •Priming operation • •Fluid compatible (not distilled water) • •Scissor action pump • • •
Parameter PGS-7-OEM PGS-40-OEM PGS-700-OEM PGS-1000-OEM
Operating pressure range -850 mbar to 7 bar -960 mbar to 40 bar 0 to 700 bar 0 to 1000 bar
Pressure media air air liquid liquid
Fine adjustment resolution 1 mbar 1 mbar 10 to 100 mbar 10 to 100 mbar
Ref port pressure connection 1/8” NPT (F) 3/8” BSP (F) 3/8” BSP (F) 3/8” BSP (F)
Ref port standard adaptor 1/4 BSP (F) 1/2 BSP (F) 3/8” BSP (F) 1/2” BSP (F)
Test point pressure connection 1/4 BSP (F) 1/4 BSP (F) 1/4 BSP (F) 1/4 BSP (F)
Hose extension 2 x 1 meter 1 x 1 meter option option
Weight 250 g 510 g 1.6 Kg 1.6 Kg
PGS-7
TECHNICAL SPECIFICATIONSELECTION GUIDE
The Eigroup PGS pump series are aremarkable new range of hand
pumps for generating vacuum, gas
and hydraulic pressure from a fewmbar up to 1000 bar. The pumps arethe ideal tool for applying test
pressures to sensors, gauges,pressure switches and any pressure
device. They are a low cost solutionfor field and workshop use and canbe supplied with the wide range of
Eigroup digital pressure indicators
or for OEM applications.• calibrate pressure device• 4 separate models
• range from Vacuum to 1000 bar• extended kit solutions to suits
different needs
The pneumatic pumps allow
pressures in excess of 600 psi to be
generated with just a few strokes ofthe pump. By changing the push-inswitching valve to vacuum, the
pump will generate vacuum down tonearly 96%.
The PGS 700 and PGS 1000hydraulic test pumps work with a
variety of different fluids, including
water and oil to easily generatepressures up to 1000 bar (14500 psi).The pump uses an unique “switch”
which allows for fast priming orfilling of the test system and then
switching as needed to a smallerstroke for easier generation at highpressure.
The desired pressure point can beeasy tuned by using the verniercontrol and a precision needle vent
valve allows for controlled venting.
All 4 pumps can be supplied as abare pump or in kit form with a hardtransit case, set of adaptors, seals
and hose.
PGS-700/1000 Hydraulic Test Kit
PGS-40 Pneumatic Test Kits
Hydraulic test kit for high pressure testing includes:• PGS-700-OEM or PGS-1000-OEM pump• Set of BSP or NPT adaptors• HTH-1000-1 high pressure hose, 1 meter• PGS700-A-G14 adaptor for HTH-1000 hose• Set of seals • PGS700-TC Robust ABS transit case with customised foam
and cells
Combined vacuum/pneumatic kit for pressure testing includes: • PGS-40-OEM pump• Set of BSP or NPT adaptors (to be specified)• Set of seals • Pressure hose with 1/4” BSP F adaptor (1 meter)• Robust ABS transit case with customised foam and cells
26
Distributed by :
Speci
ficatio
ns
may
change w
ithout notic
e
MAXiCALProcess Multifunction Calibrators
MAXi ATEX Calibration Lab 3000Multifunction Pressure and Temperature ATEX Calibrators
CAL
MFC 4150 HARTATEX Communicator
®MFC 4150 HART Communicator is the latest HART communicator from Meriam Process Technologies. HART feld devices can be confgured and trimmed using the MFC. The MFC is a full function HART Communicator with features that optimize commissioning, confguration and maintenance operations.
MFC 4150 supports all HART devices at the Universal and Common Practice command levels plus a large and growing list of devices at the Device Specifc command level. View our feld device list by going to www.meriam.com and selecting Resources / Download Center /
AdvantagesThe MFC ofers several unique features that provide HART users with a more useful, more reliable and more available communication tool. Just consider the MFC 4150’s features:
• Quick start up and connect: 15 seconds!• 60 hours battery life (w/o backlight)• Update new device profles and frmware from Meriam via the Internet – the MFC 4150 is never out of your hands • Clone / Upload / Download confgurations• Of-line mode for editing / reviewing confgurations• Document and store 200 confgurations• As-found / As-left history with Meriam DMS software• 13-line, 128 x 128 graphic, backlit display• Dongle coordinates AC power adapter and serial communications
• Full alpha-numeric keypad• Review / Edit on the fy• Quick Menu short cuts for commonly used commands• HART menu Home key• Dedicated text edit keys• Programmable lock-out settings• Contrast key for direct adjustment in any mode• Elastic hand strap, adjustable shoulder strap and soft carrying case• Left side thumb keys for one-handed navigation
WE’vE GOT
AbILITy
Intrinsically safe (approved AA alkaline batteries only)
Certifcations
II 1 G; EEx ia IIC T4Intrinsically safe, Exia Class I, Div. 1 Groups A, B, C, D: T4
ATEX