    EFFECTIVE PROTECTION

    AGAINST THE RISK OF A

    FATAL ELECTRIC SHOCK.

    RESIDUAL CURRENT DEVICE

    GROUND FAULT CIRCUIT INTERRUPTER

    ELECTRICAL SAFETY SWITCHES

    PDL ELECTRICALACCESSORIES

    RTM

  • 8/12/2019 e Limit Brochure

    2/2422

    The easy, economical way tosafeguard yourself when workingwith electricity.PDL Elimit is specifically designed to minimise the riskof a fatal electric shock when working with electricityaround the home or on the building site. It is anelectronic sensing device which constantly monitors thebalance of current flow to ensure that, should even aminute leakage occur, the PDL Elimit will switch off thepower in less than the time of a single heartbeat. Thatcould mean the difference between life and death.

    The PDL Elimit can save your life!The body is normally driven by minute electrical signals

    which control muscles and heart. If an electrical current fromthe mains passes through the body, normal body functionwill be disrupted. The effect of this disruption, calledventricular fibrillation, depends on the severity of the shockand the length of time the person is subjected to it.

    The PDL Elimit provides protection by switching the currentoff immediately. When electrical leakage to earth exceeds aslittle as 10mA (10 thousandths of one Amp) or 30mA(30 thousandths of one Amp), the PDL Elimit will switch offthe current within 30 milliseconds (30 thousandths of a

    second). Thats less than the time it takes for a singleheartbeat, and could mean the difference between life anddeath. PDLs commitment to research and development hasensured that Elimit has been engineered to meet the latestinternational standards in RCD technology.

    In the workshop and outdoors, many factors, such asdampness, faulty wiring, frayed cords and other hazards, cancontribute to a potentially lethal situation when using powertools and extension leads, electric barbeques, electriclawnmowers, temporary party lighting, pool vacuums, filters,spas, pool lights and any other outdoor electrical equipment.PDL Elimit offers personal protection against electrocutionfrom live to earth faults.Theres no doubt that, from time to time, we are allsubconsciously careless around electricity. PDL Elimit is aninsurance against this. However, it must be pointed out that

    RCD devices do not protect against all causes of electricshock such as those caused by contracting both Live andNeutral of the electrical circuit its use should not be takenas a substitute for safe electrical practices or for electricalmaintenance.

    PDL ELIMIT

  • 8/12/2019 e Limit Brochure

    3/243

    When properly connected, an electrical current flows through thelive wire (fig.1) on its way to the appliance and returns via theneutral wire (fig.2).

    If, for some reason, the current leaks (through dampness, frayedwire, faulty connection etc.), it wil l take the most direct path to earth often through a persons body. If that power is not cut off instantly,there is a strong possibility that person will die.

    The path taken by the current also contributes to the shocksseverity. A shock which flows from the hand through the arms andchest will affect both breathing and heartbeat.

    The time that a person is exposed to the shock is the greatest factorin the severity of the accident. A PDL Powerguard cuts off the powerin 30 thousandths of a second thats less than the time of asingle heartbeat!

    A leakage as little as 10mA (10 thousandths of one Amp) or 30mA(30 thousandths of one Amp) is sufficient to trip the PDL Powerguardand cut off the power to the appliance thats a minute amount ofcurrent when you consider that many appliances use as much as10 Amps.

    4

    3

    2

    1

    12

    How the PDL Powerguard Works

    3

  • 8/12/2019 e Limit Brochure

    4/244

  • 8/12/2019 e Limit Brochure

    5/2455

    NEW ZEALAND / AUSTRALIAN PRODUCTPages 6 - 13

    BRITISH STANDARD PRODUCTPages 14 - 17

    EUROPEAN PRODUCTPages 18 - 19

    NORTH AMERICAN PRODUCTPage 20

    OEM PRODUCTPage 21

    INDEX

  • 8/12/2019 e Limit Brochure

    6/246

    NEW ZEALAND/AUSTRALIAN PRODUCT

    ADAPTOR

    Cat 951Plug-in RCD Adaptor, 10A

    The PDL Powerguard plug-in RCD adaptor is ideal for providing an earth-faultprotected power source indoors. It is available in white or orange.

    Rated Voltage: 230 - 240V a.c., 50HzRated Current: 10ARated Tripping Current: 30mAAverage Tripping Time: 30msEnvironmental Protection: IP3XType Tested to: AS3190:1997

    AS3100:1994

    T E C H N I C A L S P E C I F I C A T I O N S

    REWIRABLE PLUG

    Cat 952Rewirable RCD Plug, 10A

    The PDL Powerguard RCD rewirable plug can be attached to any appliance,flexible cord or socket to accommodate the specific earth-fault protectionneeds of the user. Cat 952 is as easy to wire as any conventional plug. It isavailable in white or orange.

    Rated Voltage: 230 - 240V a.c., 50HzRated Current: 10ARated Tripping Current: 30mAAverage Tripping Time: 30msEnvironmental Protection: IP3XType Tested to: AS3190:1997

    AS3100:1994

    T E C H N I C A L S P E C I F I C A T I O N S

  • 8/12/2019 e Limit Brochure

    7/24

  • 8/12/2019 e Limit Brochure

    8/24

  • 8/12/2019 e Limit Brochure

    9/249

    SAFETY SWITCHES

    NEW ZEALAND/AUSTRALIAN PRODUCT

    Cat 596RCDVertical/Horizontal Flush Plate Mounted RCD

    The PDL Powerguard RCD is available as a 20A mounted plate version toprovide downstream protection to a number of socket outlets or permanentlywired appliances on the same circuit. The unit features double-poleswitching to protect the appliance user against an earth fault even in thesituation where Active and Neutral have been reversed.

    Rated Voltage: 230 - 240V a.c., 50HzRated Current: 20ARated Tripping Current: 30mAAverage Tripping Time: 30msMounting Centres: 84mmType Tested to: AS3190:1997

    AS3100:1994

    Cat 696RCDVertical/Horizontal Flush Plate Mounted RCD

    The PDL Powerguard RCD is available as a 20A mounted plate version toprotect a number of socket outlets or permanently wired appliances on thesame circuit. The unit features double-pole switching to protect the applianceuser against an earth fault even in the situation where Active and Neutral havebeen reversed.

    Rated Voltage: 230 - 240V a.c., 50HzRated Current: 20ARated Tripping Current: 30mAAverage Tripping Time: 30msMounting Centres: 84mmType Tested to: AS3190:1997

    AS3100:1994

    Cat 596/56RCDVertical/Horizontal Flush Plate Mounted RCD, IP56

    The PDL Powerguard RCD is available mounted in an IP56 flush plate toprovide the device with environmental protection for use in damp or dustyconditions. The unit features double-pole switching to protect the applianceuser against an earth fault even in the situation where Active and Neutral havebeen reversed.

    Rated Voltage: 230 - 240V a.c., 50HzRated Current: 20ARated Tripping Current: 30mAAverage Tripping Time: 30msEnvironmental Protection: IP56Mounting Centres: 84mmType Tested to: AS3190:1997

    AS3100:1994

    T E C H N I C A L S P E C I F I C A T I O N S T E C H N I C A L S P E C I F I C A T I O N S

    T E C H N I C A L S P E C I F I C A T I O N S

  • 8/12/2019 e Limit Brochure

    10/2410

    Cat 591FRCD 10mA or 30mA, 10A Outlet, 20A RCDProtected Circuit

    RCD Protected Single Vertical Socket OutletThe PDL Powerguard RCD combined with a single socket outlet provides anearth-fault protected power source and can be wired to provide protection toother socket outlets downstream on the same circuit. The 591FRCD - 10mAhas a rated tripping current of 10mA for more sensitive earth-fault protection,making it suitable for medical applications.

    Rated Voltage: 230 - 240V a.c., 50HzRated Current: 10A Socket Outlet, 20A - Protected CircuitRated Tripping Current: 10mA or 30mA versions availableAverage Tripping Time: 30msMounting Centres: 84mmType Tested to: AS3190:1997

    AS/NZS3112:1993

    Cat 691BRCD - 10mA or 30mA, 10A Outlet, 20A RCDProtected Circuit

    RCD Protected Single Vertical Socket OutletThe PDL Powerguard RCD combined with a single socket outlet provides anearth-fault protected power source and can be wired to provide protection toother socket outlets downstream on the same circuit. The 691BRCD - 10mAhas a rated tripping current of 10mA for more sensitive earth-fault protection,making it suitable for medical applications. Contacts remain closed in theevent of loss of supply voltage, ensuring immediate protection when thesupply is resumed.

    Rated Voltage: 230 - 240V a.c., 50HzRated Current: 10A - Socket Outlet, 20A - Protected CircuitRated Tripping Current: 10mA or 30mA versions availableAverage Tripping Time: 30msMounting Centres: 84mmType Tested to: AS3190:1997

    AS/NZS3112:1993

    Cat 694BRCD - 10mA or 30mA, 10A Outlet, 20A RCDProtected CircuitRCD Protected Single Horizontal Socket Outlet

    The PDL Powerguard RCD combined with a single socket outlet provides anearth-fault protected power source and can be wired to provide protection toother socket outlets downstream on the same circuit. The 694BRCD - 10mAhas a rated tripping current of 10mA for more sensitive earth-fault protection,making it suitable for medical applications. Contacts remain closed in theevent of loss of supply voltage, ensuring immediate protection when thesupply is resumed.

    Rated Voltage: 230 - 240V a.c., 50Hz

    Rated Current: 10A - Socket Outlet, 20A - Protected CircuitRated Tripping Current: 10mA or 30mA versions availableAverage Tripping Time: 30msMounting Centres: 84mmType Tested to: AS3190:1997

    AS/NZ3112:1993

    T E C H N I C A L S P E C I F I C A T I O N S

    T E C H N I C A L S P E C I F I C A T I O N S

    NEW ZEALAND/AUSTRALIAN PRODUCT

    SOCKET OUTLETS

    T E C H N I C A L S P E C I F I C A T I O N S

  • 8/12/2019 e Limit Brochure

    11/2411

    Cat 575LRCDShaver Socket/RCD Protected Socket Outlet

    The PDL Powerguard RCD socket outlet is available combined with auniversal shaver socket in a vertical configuration to provide an earth-faultprotected power source in damp areas such as bathrooms. Cat 575LRCDsuits the Cat 575MB wall box. Can be wired to provide protection to othersocket outlets downstream on the same circuit.

    Rated Voltage: 230 - 240V a.c., 50HzRated Current: 10A Socket Outlet, 20A Protected CircuitRated Tripping Current: 30mAAverage Tripping Time: 30msMounting Centres: 145mmType Tested to: AS3190:1997

    AS3194:1993

    Cat 675HRCDShaver Socket/RCD Protected Socket Outlet

    The PDL Powerguard RCD socket outlet is available combined with auniversal shaver socket in a horizontal configuration to provide an earth-faultprotected power source in damp areas such as bathrooms. Can be wired toprovide protection to other socket outlets downstream on the same circuit.The unit comes with a wall box.

    Rated Voltage: 230 - 240V a.c., 50HzRated Current: 10A Socket Outlet, 20A Protected CircuitRated Tripping Current: 30mAAverage Tripping Time: 30msMounting Centres: 145mmType Tested to: AS3190:1997

    AS3194:1993

    T E C H N I C A L S P E C I F I C A T I O N S T E C H N I C A L S P E C I F I C A T I O N S

    SOCKET OUTLETS (cont.)

    NEW ZEALAND/AUSTRALIAN PRODUCT

  • 8/12/2019 e Limit Brochure

    12/2412

    Cat 56C320RCDRCD Protected Socket Outlet, 20A, IP66

    Cat 56C320RCD provides IP66 environmental and earth-fault protection forthe 3-pin 20A AS3123 socket outlet. It is suitable for use in Australia and NewZealand in conditions where dust and water pose a potential hazard andfeatures double-pole switching to protect the appliance user against an earth-fault even in the situation where Active and Neutral have been reversed.

    Rated Voltage: 230 - 240V a.c., 50HzRated Current: 20ARated Tripping Current: 30mAAverage Tripping Time: 30msEnvironmental Protection: IP66Dimensions: 200 x 100 x 75mmType Tested to: AS3190:1994

    IEC529:1989AS3123:1987

    T E C H N I C A L S P E C I F I C A T I O N S

    Cat 56C310RCDRCD Protected Socket Outlet, 10A, IP66

    Cat 56C310RCD provides IP66 environmental and earth-fault protection forthe 3-pin 10A AS3112 socket outlet. It is suitable for use in Australia and NewZealand in conditions where dust and water pose a potential hazard andfeatures double-pole switching to protect the appliance user against an earth-fault even in the situation where Active and Neutral have been reversed.

    Rated Voltage: 230 - 240V a.c., 50HzRated Current: 10A - Socket Outlet, 20A - RCD Protected CircuitRated Tripping Current: 30mAAverage Tripping Time: 30msEnvironmental Protection: IP66Dimensions: 200 x 100 x 75mmType Tested to: AS3190:1994

    IEC529:1989AS/NZS3112 : 1993

    Cat 56RCD2056 Series Plate, 20A, IP66

    The PDL Powerguard RCD is available mounted in a 56 Series IP66 one gangenclosure giving earth-fault protection to other socket outlets wireddownstream on the same circuit. The unit features a double-pole switch toprotect the appliance user against an earth fault even in the situation whereActive and Neutral have been reversed.

    Rated Voltage: 230 - 240V a.c., 50HzRated Current: 20ARated Tripping Current: 30mAAverage Tripping Time: 30msEnvironmental Protection: IP66Dimensions: 100 x 100 x 75mmType Tested to: AS3190:1994

    AS3100:1994IEC529:1989

    Cat 56C316RCDRCD Protected Socket Outlet, 16A, IP66

    Cat 56C316RCD provides IP66 environmental protection and earth-faultprotection for the 3-pin IEC309 socket outlet. It features double-poleswitching to protect the appliance user against an earth-fault even in thesituation where Active and Neutral have been reversed.

    Rated Voltage: 250V a.c., 50HzRated Current: 16A - Socket Outlet, 20A - RCD Protected CircuitRated Tripping Current: 30mAAverage Tripping Time: 30ms

    Environmental Protection: IP66 when flaps are closed, IP44 with plug fittedDimensions: 200 x 100 x 75mmType Tested to: AS3190:1994

    IEC309:1988IEC529:1989

    T E C H N I C A L S P E C I F I C A T I O N S T E C H N I C A L S P E C I F I C A T I O N S

    T E C H N I C A L S P E C I F I C A T I O N S

    NEW ZEALAND/AUSTRALIAN PRODUCT

    IP66 INDUSTRIAL SWITCHGEAR

  • 8/12/2019 e Limit Brochure

    13/2413

    NEW ZEALAND/AUSTRALIAN PRODUCT

  • 8/12/2019 e Limit Brochure

    14/2414

    REWIRABLE PLUGADAPTOR

    Cat 952BRewirable RCD Plug, 13A

    The PDL Elimit rewirable RCD plug, in BS format, can be wired to anyappliance, cord or trailing socket to provide earth-fault protection. The unit isas easy to wire as a standard plug and is provided with a 13A fuse to giveover-current protection. The Cat 952B is ideal for situations where a specificappliance needs to be protected.

    Rated Voltage: 240V a.c., 50HzRated Current: 13ARated Tripping Current: 30mAAverage Tripping Time: 30msEnvironmental Protection: IP3XType Tested to: BS7071:1992

    BS1363:1984

    Cat 1951Plug-in RCD Adaptor, 13A

    The PDL Elimit RCD adaptor is suitable for use with most portable electricaltools and appliances providing earth-fault protection from the socket outlet.It features double-pole switching, ie both Live and Neutral are independentlyswitched, to protect against faulty wiring. The RCD trips out automatically onthe loss of power.

    Rated Voltage: 240V a.c., 50HzRated Current: 13ARated Tripping Current: 30mAAverage Tripping Time: 30msEnvironmental Protection: IP3XType Tested to: BS7071:1992

    BS1363:1984

    T E C H N I C A L S P E C I F I C A T I O N S T E C H N I C A L S P E C I F I C A T I O N S

    BRITISH STANDARD PRODUCT

    Cat 955BRCD Cordset, 13A

    The PDL Elimit RCD cordset is the safer alternative to a normal extensioncord, providing earth-fault protection to most portable electrical tools andappliances. The IP33 environment protection makes it ideal for use ingarages and other areas where electrocution is a hazard.

    Rated Voltage: 240V a.c., 50HzRated Current: 13ARated Tripping Current: 30mAAverage Tripping Time: 30ms

    Environmental Protection: IP33Cord Length: 2mType Tested to: BS7071:1992

    BS1363:1984

    T E C H N I C A L S P E C I F I C A T I O N S

    CORDSET

  • 8/12/2019 e Limit Brochure

    15/2415

    SAFETY SWITCHES

    Cat 1796RCDFlush Plate Surface Mounted RCD, 13A (2-Gang Plate)Type A detects loss of supply or neutral.Type B contacts remain closed in the event of loss of supply voltage.

    PDLs 1700 Series range of high-impact surface accessories offers an Elimitflush plate mounted RCD for spur connection of a socket or fixed applianceoff the ring main. The unit features double-pole switching to protect theappliance user against an earth-fault even in the situation where Live andNeutral have been reversed. The 1796RCD is available with a plastic or ametal mounting box.

    Rated Voltage: 240V a.c., 50HzRated Current: 13ARated Tripping Current: 30mAAverage Tripping Time: 30msMounting Centres: 120mmType Tested to: BS4293:1983

    Cat 1596RCDFlush Plate Mounted RCD, 13A (2-Gang Plate)Type A detects loss of supply or neutral.Type B contacts remain closed in the event of loss of supply voltage.

    The PDL Elimit flush plate mounted RCD is designed for spur connection of asocket or fixed appliance off the ring main. The unit features double-poleswitching to protect the appliance user against an earth-fault even in thesituation where Live and Neutral have been reversed.

    Rated Voltage: 240V a.c., 50HzRated Current: 13ARated Tripping Current: 30mAAverage Tripping Time: 30msMounting Centres: 120mmType Tested to: BS4293:1983

    T E C H N I C A L S P E C I F I C A T I O N S

    T E C H N I C A L S P E C I F I C A T I O N S

    BRITISH STANDARD PRODUCT

    POWERBOARDS

    Cat 070RCDRCD Protected 4-Gang Trailing Socket, 13A

    The PDL Elimit rewireable RCD plug is available attached to a 4-gang trailingsocket to provide earth-fault protection to a number of appliances. It isideally suited to applications where a number of tools or appliances are to beoperated at the same time. The trailing socket is fitted with a patented quick-release wall-mounted bracket.

    Rated Voltage: 240V a.c., 50HzRated Current: 13ARated Tripping Current: 30mARated Tripping Time: 30msEnvironmental Protection: IP3X - plug onlyCord Length: 1mType Tested to: BS7071:1992

    BS1363:1984

    Cat 071RCDRCD Protected 4-Gang Switched Trailing Socket, 13A

    The PDL Elimit rewirable RCD plug is also available attached to a 4-gangswitched trailing socket to provide earth-fault protection to a number ofappliances. The trailing socket is fitted with a switch providing convenientcontrol of the supply of electricity to appliances connected to it. A neon fittedto the trailing socket shows whether power is being supplied.

    Rated Voltage: 240V a.c., 50HzRated Current: 13ARated Tripping Current: 30mARated Tripping Time: 30msEnvironmental Protection: IP3X - plug onlyCord Length: 1mType Tested to: BS7071:1992

    BS1363:1984

    T E C H N I C A L S P E C I F I C A T I O N S T E C H N I C A L S P E C I F I C A T I O N S

  • 8/12/2019 e Limit Brochure

    16/2416

    Cat 1561RCDRCD Protected Single Socket Outlet, 13A (2-Gang Plate)

    Type A detects loss of supply or neutral.Type B contacts remain closed in the event of loss of supply voltage.

    The PDL Elimit RCD one-gang BS socket outlet features double poleswitching to protect the appliance user against earth faults even in thesituation where Live and Neutral have been reversed.

    Rated Voltage: 240V a.c., 50HzRated Current: 13ARated Tripping Current: 30mAAverage Tripping Time: 30msMounting Centres: 120mmType Tested to: BS7288:1990

    BS1363:1984

    Cat 1761RCDRCD Protected Surface Mounted Single Socket Outlet, 13A (2-Gang Plate)

    Type A detects loss of supply or neutral.Type B contacts remain closed in the event of loss of supply voltage.

    The PDL Elimit RCD one-gang BS socket outlet features double poleswitching to protect the appliance user against earth faults even in thesituation where Live and Neutral have been reversed. The unit is availablewith a plastic or metal mounting box.

    Rated Voltage: 240V a.c., 50HzRated Current: 13ARated Tripping Current: 30mAAverage Tripping Time: 30msMounting Centres: 120mmType Tested to: BS7288:1990

    BS1363:1984

    T E C H N I C A L S P E C I F I C A T I O N S

    T E C H N I C A L S P E C I F I C A T I O N S

    SOCKET OUTLETS

    BRITISH STANDARD PRODUCT

  • 8/12/2019 e Limit Brochure

    17/2417

    BRITISH STANDARD PRODUCT

    IP66 INDUSTRIAL SWITCHGEAR

    Cat 1562RCDRCD Protected Double Socket Outlet, 13A

    Type A detects loss of supply or neutral.Type B contacts remain closed in the event of loss of supply voltage.

    The PDL Elimit RCD two-gang BS socket outlet features double poleswitching to protect the appliance user against earth faults even in thesituation where Live and Neutral have been reversed.

    Rated Voltage: 240V a.c., 50HzRated Current: 13ARated Tripping Current: 30mAAverage Tripping Time: 30msMounting Centres: 120mmType Tested to: BS7288:1990

    BS1363:1984

    Cat 1762RCDRCD Protected Surface Mounted Double Socket Outlet, 13A

    Type A detects loss of supply or neutral.Type B contacts remain closed in the event of loss of supply voltage.

    The PDL Elimit RCD two-gang BS socket outlet features double poleswitching to protect the appliance user against earth faults even in thesituation where Live and Neutral have been reversed. The unit is availablewith a plastic or metal mounting box.

    Rated Voltage: 240V a.c., 50HzRated Current: 13ARated Tripping Current: 30mAAverage Tripping Time: 30msMounting Centres: 120mmType Tested to: BS7288:1990

    BS1363:1984

    T E C H N I C A L S P E C I F I C A T I O N ST E C H N I C A L S P E C I F I C A T I O N S

    56C313RCDRCD Protected Socket Outlet, 13A, IP66

    Cat 56C313RCD provides IP66 environmental and earth-fault protection forthe 3-pin 13A BS1363 socket outlet. It is suitable for use in conditions wheredust and water pose a potential hazard and features double-pole switching toprotect the appliance user against an earth-fault even in the situation whereActive and Neutral have been reversed.

    Rated Voltage: 240V a.c., 50HzRated Current: 13A - Socket Outlet, 20A - RCD Protected CircuitRated Tripping Current: 30mAAverage Tripping Time: 30msEnvironmental Protection: IP66Dimensions: 200 x 100 x 75mmType Tested to: AS3190:1994

    IEC529:1989BS1363:1984

    T E C H N I C A L S P E C I F I C A T I O N S

    SOCKET OUTLETS (cont.)

  • 8/12/2019 e Limit Brochure

    18/2418

    EUROPEAN PRODUCT

    ADAPTORS

    REWIRABLE PLUG

    Cat 951SPlug-in RCD Adaptor, 16A (Side-Earthing Contacts)

    The PDL Elimit plug-in RCD adaptor is available with side-earthing contacts andis ideal for providing an earth-fault protected power source indoors. It issuitable for use with most portable electrical tools and appliances providingearth-fault protection at the socket outlet.

    Rated Voltage: 250V a.c., 50HzRated Current: 16AEnvironmental Protection: IP3XRated Tripping Current: 30mAAverage Tripping Time: 30msType Tested to: Certified to para 5.2 EMVG respectively Art 10.2 of the EMC

    Council Directive EN55104: 1995, Category II.Tested to EN61008-1:1994 & A2 & A11, EN61008-2-1/08.94,IEC 884-1/06.94 & IEC 884-1/A1/12.94.Complies with draft standard 23E/263/FDIS for portable RCDproducts. Complies with low voltage directive 73/23/EEC and93/68/EEC.

    Cat 951FPlug-in RCD Adaptor, 16A (Pin-Type Earth Contact)

    The PDL Elimit plug-in RCD adaptor is available in the pin-type earth contactformat, predominantly used in France. It is suitable for use with most portableelectrical tools and appliances providing earth-fault protection at the socketoutlet.

    Rated Voltage: 250V a.c., 50HzRated Current: 16AEnvironmental Protection: IP3XRated Tripping Current: 30mAAverage Tripping Time: 30msType Tested to: Certified to para 5.2 EMVG respectively Art 10.2 of the EMC

    Council Directive EN55104: 1995, Category II.Tested to EN61008-1:1994 & A2 & A11, EN61008-2-1/08.94,IEC 884-1/06.94 & IEC 884-1/A1/12.94.Complies with draft standard 23E/263/FDIS for portable RCDproducts. Complies with low voltage directive 73/23/EEC and93/68/EEC.

    Cat 952SRewirable RCD Plug, 16A

    The PDL Elimit rewirable RCD plug is designed for attachment to appliancecords providing earth-fault protection for the user. The plug is also suitable foruse in French-style socket outlets and wiring of the unit is as easy as anyconventional plug.

    Rated Voltage: 250V a.c., 50HzRated Current: 16ARated Tripping Current: 30mAAverage Tripping Time: 30ms

    Environmental Protection: IP3XType Tested to: Certified to para 5.2 EMVG respectively Art 10.2 of the EMCCouncil Directive EN55104: 1995, Category II.Tested to EN61008-1:1994 & A2 & A11, EN61008-2-1/08.94,IEC 884-1/06.94 & IEC 884-1/A1/12.94.Complies with draft standard 23E/263/FDIS for portable RCDproducts. Complies with low voltage directive 73/23/EEC and93/68/EEC.

    FI

    T E C H N I C A L S P E C I F I C A T I O N S T E C H N I C A L S P E C I F I C A T I O N S

    T E C H N I C A L S P E C I F I C A T I O N S

    geprfte Sicherheit T V R h e i n l a n d

    FIgepr fte Sicherheit T V R h e i n l a n d

  • 8/12/2019 e Limit Brochure

    19/2419

    Cat 56C216D/RCDRCD Protected Socket Outlet, 16A, IP66

    Cat 56C216D/RCD provides IP66 environmental and earth-fault protection forthe 16A Socket outlet. It is suitable for use in conditions where dust andwater pose a potential hazard and features double-pole switching to protectthe appliance user against an earth-fault even in the situation where Activeand Neutral have been reversed.

    Rated Voltage: 230 - 240V a.c., 50HzRated Current: 16A - Socket Outlet, 20A - RCD Protected CircuitRated Tripping Current: 30mAAverage Tripping Time: 30msEnvironmental Protection: IP66 when flaps are closedDimensions: 200 x 100 x 75mmType Tes ted to: EN61008:1994 (re levant clauses)

    IEC529:1989CEE7: 1963

    T E C H N I C A L S P E C I F I C A T I O N S

    Cat 56C216F/RCDRCD Protected Socket Outlet, 10A, IP66

    Cat 56C216/RCD provides IP66 environmental and earth-fault protection forthe 16A socket outlet with pin-type earthing contacts, predominantly used inFrance. It is suitable for use in conditions where dust and water pose apotential hazard and features double-pole switching.

    Rated Voltage: 240V a.c., 50HzRated Current: 16A - Socket Outlet, 20A - RCD Protected CircuitRated Tripping Current: 30mAAverage Tripping Time: 30msEnvironmental Protection: IP66 when flaps are closedDimensions: 200 x 100 x 75mmType Tested to: EN61008:1994 (relevant clauses)

    IEC529:1989CEE7:1963

    T E C H N I C A L S P E C I F I C A T I O N S

    IP66 INDUSTRIAL SWITCHGEAR

    EUROPEAN PRODUCT

  • 8/12/2019 e Limit Brochure

    20/2420

    ADAPTOR

    NORTH AMERICAN PRODUCT

    Cat 951U-3Plug-in GFCI Adaptor

    The PDL plug-in GFCI adaptor provides an earth-fault protected power sourcethrough three socket outlets. It is suitable for use with most portable electrictools and appliances.

    Rated Voltage: 120V a.c.Rated Current: 15ARated Tripping Current: 6mARated Tripping Time: 30msType Tested to: UL 943

    CSA C 22.2 No. 144M91

    Cat 952URewirable GFCI Plug

    The PDL rewirable GFCI plug is designed for attachment to appliance cordsto provide earth-fault protection. The unit is as easy to wire as a standardplug. With NEMA5 environment protection, it is ideal for use in situationswhere dust and water pose a potential problem.

    Rated Voltage: 120V a.c.Rated Current: 15ARated Tripping Current: 6mARated Tripping Time: 30msEnvironmental Protection: NEMA 5Type Tested to: UL 943

    CSA C 22.2 No. 144M91

    T E C H N I C A L S P E C I F I C A T I O N ST E C H N I C A L S P E C I F I C A T I O N S

    REWIRABLE PLUG

  • 8/12/2019 e Limit Brochure

    21/2421

    OEM PRODUCT

    CORDSET RCD UNITS

    Cat 955RW-30Rewirable Cordset, 30mA

    Features:IP56 construction.Screw connections.Universal - suitable for all countries of the world.Designed to meet world standards. Complies with all relevant European standardsand requirements.

    Rated Voltage: 250V a.c.Rated Current: 16ARated Tripping Current: 30mAAverage Tripping Time: 30msEnvironmental Protection: IP56. IP44 for SEMKO approved version.Type Tested to: AS/NZS:3175.1:1994

    EN61008-1:1984 & A2 and A11, EN61008-2-1:1994.Complies to draft standard 23E/263/FDIS.

    Cat 955RW-10Rewirable Cordset, 10mA

    Features:IP56 construction.Screw connections.Universal - suitable for all countries of the world.Designed to meet world standards. Complies with all relevant European standardsand requirements.

    Rated Voltage: 250V a.c.Rated Current: 16ARated Tripping Current: 10mAAverage Tripping Time: 30msEnvironmental Protection: IP56. IP44 for SEMKO approved version.Type Tested to: AS/NZS:3175.1:1994

    EN61008-1:1984 & A2 and A11, EN61008-2-1:1994.Complies to draft standard 23E/263/FDIS.

    Cat 955RWURewirable Cordset, 6mA

    Features:Rainproof.Screw connections.Universal - suitable for all countries of the world.Designed to meet world standards.

    Rated Voltage: 120V a.c.Rated Current: 15ARated Tripping Current: 6mAAverage Tripping Time: 30msEnvironmental Protection: NEMA 5Type Tested to: UL943: Third Edition

    Cat 596PMRCD Adaptor Plate

    Tough polycarbonate construction. Large terminals. Designed with theappliance manufacturer in mind. Small size to fit a wide range of designs.

    Rated Voltage: 240V a.c.Rated Current: 20ARated Tripping Current: 10 or 30mAAverage Tripping Time: 30msType Tested to: AS3190:1997

    AS3100:1994

    T E C H N I C A L S P E C I F I C A T I O N S

    T E C H N I C A L S P E C I F I C A T I O N S

    T E C H N I C A L S P E C I F I C A T I O N S

    ADAPTOR PLATE

    T E C H N I C A L S P E C I F I C A T I O N S

  • 8/12/2019 e Limit Brochure

    22/24

  • 8/12/2019 e Limit Brochure

    23/2423

    Independent third party testing,your guarantee of quality

    The design and manufacture of products by PDLIndustries has always been backed by third partytesting and development facilities.

    PDL uses Parkside Laboratories, an independent IANZ-registered electrical laboratory, for its product testingand IANZ-endorsed test reports to ensure internationalproduct acceptance.

    Parkside Laboratories offers testing, calibration andcertification services in the fields of electrical, EMC,environmental, calibration and metrology, with testprocedures performed in accordance with ISO Guide25 1990 and ISO 9002 1987. Their in-house QualityManagement System meets International AccreditationNew Zealand (formerly known as TELARC) standards,ensuring that all procedures meet or exceed therequirements of the New Zealand Code of LaboratoryManagement Practice and through their laboratory inMelbourne, Australia the National Association of

    Testing Authorities (NATA).

    An independent International Accreditation New Zealand registered electrical laboratory is used for product testing to ensure compliance to international standards and product quality.

    INTERNATIONAL TESTING SYSTEMS

    The installation of a new, high-power short circuit testfacility at the Melbourne lab has enabled ParksideLaboratories to extend the range of NATA accreditedtest facilities on offer to industry. The new test centre isthe only privately funded facility of its type in Australia.

    As an International Accreditation New Zealandregistered laboratory, Parkside Laboratories testresults are recognised and accepted by otheraccreditation authorities in the following countries:

    Australia, the United States of America, Ireland, theUnited Kingdom, Portugal, Spain, France, Belgium, theNetherlands, Germany, Austria, Switzerland, Italy,Denmark, Norway, Sweden, Finland, China, ChineseTaipei, Hong Kong, Singapore andSouth Africa.

    This combination of research, development and qualityassurance has underpinned the current success of PDLHoldings ten subsidiary companies and their continuedfurther growth.

    23

  • 8/12/2019 e Limit Brochure

    24/24

    THE PDL GROUPOF COMPANIES

    For 60 years, the PDL Group ofCompanies has built an enviableinternational reputation foundedon the concept that continuous

    quality is quality you trust.

    PDL is globally recognised formanufacturing the very best in

    electrical accessories, industrialswitchgear, AC variable speed

    drives, custom plastic products

    and electrical consumerappliances to the highestinternational standards. PDL

    products are now distributed toover 40 countries including

    New Zealand, Australia, the UnitedKingdom, Europe, Asia, NorthAmerica, the Pacific and the

    Middle East.

    Continuous investment in researchand development has provided thePDL Group with some of the most

    sophisticated world-widetechnology and this, together withinnovation, design excellence and

    independent third-party qualityassurance schemes, has ensuredPDL an excellent reputation in the

    international market.

    The commitment to R&D hasunderpinned the current successof PDL Holdings ten subsidiarycompanies and their continuedfurther growth. Currently, the

    Group employs 2100 people overthree continents - Australasia,Asia and Europe and has anannual turnover in excess of

    $NZ360 million.

    PDL GROUP PRODUCTS

    PDL electrical wiring accessories for domestic, commercial and industrial applications,including PDL 600 Designer Series.

    PDL PIR Sensors, PDL Residual Current Devices and PDL Powerboards.

    Goldair fan heaters and cooling fans.

    Modempak cable management and distribution products for the Data andTelecommunications industries.

    AC Motor Speed Controllers including Xtravert, Microdrive-3, Microdrive-i andMicrodrive-Elite, Nu-Start AC Motor Soft Starters.

    D-PRO Air Circuit Breakers, CFS Fuse Switch Units, Current Transformers, Power AnalysersMegatiker Moulded Case Circuit Breakers and various fusegear.

    Specialist plastic custom moulding including injection and blow moulded bottles, packs andclosures for all sectors of the packaging industry.

    RTM

    PDL HOLDINGS LTD THE GROUP

    Head Office: P O Box 1367, Christchurch, New Zealand.Manufacturers of Electrical Products

    Distributed internationally by:

    PDL INDUSTRIES LTD Continuous quality is quality you trust

    PDL Industries Limited,Telarc Reg. No. 061registered to ISO 9002.

    NATIONALACCREDITATION

    OFCERTIFICATIONBODIES

    ISO 9002CERT NO. 11595

    Q U A

    L I T Y

    A S S E S S E D

    REGISTEREDSUPPLIER


Recommended