EVERY LIFE HAS A PURPOSE…
GasGard® XL Monitor
GasGard XL Controller
GasGard XL Controller
Multi-channel, wall-mounted economical controller for all of your gas monitoring needs.
A practical partner for hazardous gas monitoring.
GasGard XL Controller
Features and Benefits Expandable up to 8 channels 4-20mA input
Ultima X Transmitters Ultima MOS-5® Gas Detector FlameGard 5® Flame Detector Ultima OPIR-5™ Open Path Gas Detector
Fully configurable by laptop via USB or RS-485 Modbus connection
Event log upload by USB or RS-485 Ethernet w/Modbus TCP/IP for SCADA visualization interface Multi-language display (13)
GasGard XL Controller
Features and Benefits Large graphic display LEDs for each channel Common relay board Pre-formed cable entries Easy maintenance
Hot-swap channel boards Robust ABS housing – flame retardant V0 rating Temperature rating -10oC to +50oC
GasGard XL Controller
Standard configuration 100 W (24VDC) power supply 5 common relays
2 alarms levels 2 horns Failure
Internal buzzer 85 dB Main board includes space
for 4 channel cards
GasGard XL Controller
Options 2 additional relays per channel
Configurable by zone, group, voting Back-up battery 2.2A Sensor extension board (for channels 5-8)
GasGard XL Controller
Channel cards Sensor extension board
Battery backup (optional)
Main board
Common relaysUSB & RS485 connections
Wiring for channel cards
Additional relay board
100 W power supply
GasGard XL Controller Display
DateFlame symbol Time
STEL & TWA alarms
Actual values
Sensor fault
Battery (not included)
Bold indicates active channelEvents archive
Alarm 2
Alarm 1
GasGard XL Controller Display
Description Gas
mA, active card
STEL and TWA set points
Alarm 2, 25 ppm, increasing, latching
Alarm 1, 15 ppm, increasing
Fault condition
Channel #
GasGard XL Controller Display
Horn relay #1
Channel cards
Horn to activate on condition
Alarm type
Voting, 4 out of 5 conditions
Relay ‘Status’ Normally de-energized
GasGard XL Configuration Software
Must check box, save and download settings to activate battery back-up
Date Format
GasGard XL Configuration Software
Configure alarm details
Channel details screen
Select channels to configure
Input customized info
GasGard XL Configuration Software
Relay outputs screen
Check relay boards if included
Horns and additional relays can be configured
Upload/ download to Gasgard XL
A1 & A2 cannot be modified
GasGard XL Controller Approvals
cCSAus Fire, Shock & Safety
CSA 22.2 No. 61010-1 for Canada UL 61010-1 for USA
Performance CSA 22.2 No.152 for Canada ISA 12.13 for USA
ATEX SIL 2 IP56/NEMA 4X