e-XCSINGLE STAGE, DOUBLE SUCTION CENTRIFUGAL PUMPS – 60 HZ
BReXC_60HZ R1
2
Designed and manufactured by the global leader in pumping technology, the Xylem e-XC single
stage, double suction centrifugal pump provides a more powerful and efficient solution for a wide
range of applications including oil & gas, power generation, general industry, water utilities, and
mining.
It is a configurable single-stage horizontal split-case pump with extensive flow and head coverage
and a common in-line configuration for easier installation of new and retrofit pumping systems.
Coupled with a complete range of materials of construction to choose from, this pumping solution
is here to meet your performance demands at the best value.
• More powerful: As a replacement to the legacy AC
Series 8100, 8300, and 9100 pumps, we provide
efficient pumping down to 11 gpm [2.5 m3/hr]. With
a top end flow rate of up to 57,061 gpm [12,960 m3/
hr], the e-XC can easily handle medium and large
capacity systems and higher head as well. For even
larger applications, Xylem’s AC Custom pump range is
available to meet any customer’s needs.
• Tailor made: Full range of standard materials including
duplex and super duplex plus engineered to order
options.
Hydraulic Specifications1
Maximum flow: 57,061 gpm [12,960 m3/hr]
Maximum head: 873 ft. [266 m]
Fluid Temperature Range
Standard: 0 to 250°F [-18 to 121°C]
Casing Operating Pressure
Cast Iron: 175 psi [12 bar]
Ductile Iron: 400 psi and 450 psi [28 and 31 bar]
Features and Benefits
Technical Specifications
• Longer running life: Thanks to a shorter shaft, this
pump can run up to 3 times longer (L10 100,000 hours)
before the bearings need to be changed.
• Peace of mind: With optional temperature and vibration
sensors on the bearing bracket, real time measurement
is available to help predict maintenance needs. Spare
rotating elements and parts kits are available.
• True partners: Through rugged engineering backed
by Xylem’s responsive, knowledgeable distribution
network, this pump is designed to give you the long
lasting and reliable service that you expect.
Flange Drilling Specifications
125# and 250#, ASME/ANSI B16.1
DIN 16/25/40, EN 1092
AWWA Class D, Class F
1 Hydraulic performances compliant with ANSI/HI 14.6 and ISO
9906:2012 (Grade 2B)
3
60 Cycle Performance Range2-Pole
4-Pole
300
200
100
50
30
20
10
5
Tota
l Hea
d (F
eet)
20 30 40 60 100 200 300 400 600 1000 2000 Flow (m3/h)
1000
600
400300
200
1008060
40
20
Tota
l Hea
d (M
eter
s)
100 200 400 600 8001000 2000 30004000 6000 8000 Flow (GPM)
4x5x6.55x6x7.5
3x5x8.5 5x8x9.5
4x6x133x5x12.5
6x10x11
5x8x14
5x8x12
4x6x103x5x
11
Series e-XC3560 RPM
300
200140100
50
30
20
10
5
310 20 30 50 100 200 300 400 600 1000 2000 3000 4000 6000 Flow (m3/h)
Tota
l Hea
d (
Met
ers)
40 60 80 100 200 400 600 8001000 2000 3000 4000 6000 800010000 20000 30000Flow (GPM)
1000
600
400300
200
1008060
40
20
10
Tota
l Hea
d (
Fee
t)
Series e-XC1780 RPM
6x8x6.5
5x8x9
3x5x11
3x5x13.5
4x6x14.54x6x16
5x8x19
6x8x22
8x10x20
8x8x810x10x8
12x12x9
12x12x10
5x8x9.5 8x10x1014x14x12
6x8x128x10x13.5
4x6x10
4x6x135x8x12
6x8x145x8x15.5
6x8x18
16x16x13.5
18x20x15.5
20x24x18
14x18x1812x16x18
12x14x13
10x12x15.514x16x15
10x12x19
12x16x2214x18x21
16x20x20.5
10x12x24
12x16x28
16x20x2314x16x
27.5
8x10x17
8x10x21
Every e-XC pump has two distinct impeller designs - i.e. the 3x5x8.5 model is also available as 3x5x8. See individual performance curves for more details.
4
60 Cycle Performance Range6-Pole
8-Pole
300
200
140
100
50
30
20
10
Tota
l Hea
d (F
eet)
20 30 50 100 200 400 600 1000 2000 4000 6000 10000 Flow (m3/h)
1000
600
400
300
200
10080
60
40
Tota
l Hea
d (M
eter
s)
80 100 200 400 600 8001000 2000 4000 6000 10000 20000 40000 Flow (GPM)
10x12x30
14x1
6x30
.5
Series e-XC1180 RPM
20x28x36
16x24x31.5 24x32x31.5
20x28x28
20x24x24.5
16x20x2120x24x20.5
14x20x
26.5
28x28x21
32x32x23
24x28x24
28x32x23.5
28x32x2624x28x22.5
300
200
140
100
50
30
20
10
5
3
Tota
l Hea
d (F
eet)
200 300 400 600 1000 2000 3000 4000 6000 10000 20000 Flow (m3/h)
1000
600
400300
200
1008060
40
20
10
Tota
l Hea
d (M
eter
s)
800 1000 2000 3000 4000 6000 8000 10000 20000 30000 40000 60000 80000 Flow (GPM)
28x32x30.5
24x32x43.5
14x20x33
Series e-XC890 RPM
16x24x3824x32x39
28x32x34
28x36x39
Every e-XC pump has two distinct impeller designs - i.e. the 10x12x30 model is also available as 10x12x28.5. See individual performance curves for more details.
5
Range overview/specificationsMaterials of Construction*
COMPONENT STANDARD OPTION OTHER AVAILABLE OPTIONS
CasingCast Iron NO. 35
Ductile Iron 65-45-12
316 SS Duplex SS Super Duplex
Shaft (seal on shaft)1 420 SS Duplex SS
Shaft (seal on sleeve) 5140 4135
Impeller 304 SS — 316 SS — Duplex SS Super Duplex
Casing wear rings Bronze C90300 304 SS 316 SS Duplex SSSuper
DuplexNitronic 60
Imp. wear rings 304 SS — 316 SS — Duplex SS Super Duplex
Shaft sleeves 304 SS 316 SS Duplex SS
Shaft sleeve nuts 304 SS 316 SS Duplex SS
Packing1 Style 608D Graphite —
Lantern ring1 PTFE Cast Iron
Seal flush lines 304 SS 316 SS Nylon
Mechanical seal type2 MR3 MR4 MR6 MR8
Other casted components Cast Iron NO. 30 —
Bearings Steel —
Bolts Steel —
Pipe Plugs Steel —
“O” Rings Rubber (FKM) —
Gaskets Fish Paper —
Retaining ring 304 SS —
Shoulder rings Steel —
Protective Guard Steel —
1Optional component with a standard material configuration
2For mechanical seal material configuration details, see ‘Mechanical Seals’ section
* Standard construction (dry shaft) cast iron, ductile iron or CF8 (316 SS) enclosed e-XC pumps, fitted with either CF8 (304 SS) or CF8M (316 SS) impeller and impeller wear rings, and bronze casing wear rings are certified to both NSF/ANSI/CAN 61 and 372 standards. Standard construction pumps are certified for use with either MR3 (C/SiC/EPDM or SiC/SiC/EPDM) metal pusher and MR4 (C/SiC/EPDM) rubber bellow mechanical seals. Optional wet shaft construction e-XC pumps with either 420 SS shaft with the same casing, impeller assembly, and mechanical seal configurations listed above are also certified to NSF/ANSI/CAN 61 and 372 standards.
USC
®
6
Sealing SolutionsPacking
PTFE lantern ring with style 608D graphite packing2
Up to 300 psi [20.7 bar]
MR4
Unbalanced unitized industrial rubber bellow seal
Up to 4” [110 mm] and 175 psi [12 bar]1
MR3
Balanced industrial metal pusher seal
Up to 8.25” [210 mm] and 450 psi [31 bar]1
MR6 & MR8
Industrial metal pusher cartridge seals
MR6: Configured for seal on shaft
MR8: Configured for seal on sleeve
Up to 7.375”/8.25” [185/210 mm] and 450 psi [31 bar]1
Fluid Temperature Range
Mechanical seals: 0 to 250°F [-18 to 121°C]
Packing: 0 to 250°F [-18 to 121°C] at 4000 FPM [20 m/s] shaft speed
Material Configurations
1. Carbon/Silicon Carbide/EPDM3
2. Silicon Carbide/Silicon Carbide/EPDM
3. Carbon/Silicon Carbide/FKM
4. Silicon Carbide/Silicon Carbide/FKM
1 Pressure rating represents dynamic working pressure. Seals
are rated for 1.5X dynamic pressure under static loading.
2 Packing ring and packing materials only available in cast iron
and PTFE yarn respectively (China only).
3 Standard seal material configuration
Seal Flushing
All e-XC pumps include plan 11 flushing (standard) which ensures seal components stay clear of debris and extends seal life. Plan 11 flushing diverts water traveling through the pump volute into either seal faces or packing glands.
MR3 Cross-Section
MR4 Cross-Section
MR6 Cross-Section
7
Motor Specifications & DrivesMotor Offerings
• NEMA premium efficiency per EISA 2010
• NEMA MG-1 performance
• Max 3-phase ambient temperature of 104°F (40°C)
• Inverter ready
• Class F insulation
• Voltages: 3 x 460/575 V
• Poles: 2, 4, 6 and 8
• Open Drip Proof (ODP) enclosure
• Totally Enclosed Fan Cooled (TEFC) enclosure (optional)
• PTC/RTD sensors (optional)
Aquavar® IPC Drive Options
• 1.5/125 and 150/600 hp ranges
• Temperature Rating: 14°F to 113°F (-10°C to 45°C)
• Built-in BACnet, Modbus RTU, N2 Metasys FLN
• Optional mains disconnect
• 2 analog inputs, 1 analog output
• 4 digital inputs, 2 digital outputs
Couplings
Baseplate and Coupling Guard
COUPLING TYPE STANDARD OPTIONAL
Spacer N/A Duraflex® Falk Steelflex® Falk Gear Type
Non-Spacer Duraflex® Falk Steelflex®1 Falk Steelflex® Falk Gear Type
1Standard only if Duraflex® coupling size is not available
1Alignment screws only applicable after 215 frame size
ITEM FEATURES
BaseplateGroutedFormed steel frameAlignment jacking screws1
Coupling GuardANSI/OSHA compliantScratch resistant powder coating
Drip Pan (Optional) Galvanized steel
Xylem Inc.Phone: (866) 673-0428 • Fax: (888) 322-5877www.xyleminc.comAll other trademarks or registered trademarks are property of their respective owners.
© 2020 Xylem Inc. BReXC_60HZ R1 April 2020
Other Standard Features
Pump Accessories
• Equipped with shaft guards for increased safety and protection against rotating components.
• Short shaft design ensures less deflection and longer bearing life.
• Vibration, temperature and pressure ports standard for easy monitoring.
Bearing Lubrication
Oil Lubrication Kit
• 4 oz. Trico oiler
• NPT sight glass
• NPT breather vent
Temperature Monitoring
Prosense ETS Series Digital Temperature Sensor
• -58°F to 302°F [-50°C to 150°C]
• Outputs 1 and 2: Switch PNP, N.O./N.C. selectable or 4 to 20 mA, 4-digit display
Pump Selection
Using Xylem’s Intellitronic X selection software for pump selection will save you time due to its easy to use platform and selection flexibility. With ability to be designed and configured in a multitude of ways, the Xylem e-XC single stage, double suction centrifugal pump is available in a variety of sizes, models and materials which allow you to perfectly configure it for your system requirements.
Vibration Monitoring
PCB Piezotronics Industrial Velocity Transmitter
• Output: 4 to 20 mA
• 0 to 1 in/sec pk
• 3 to 1k Hz
• 2-pin connection
Pressure Monitoring
American Sensor Technologies Pressure Sensor
• AST range 0 to 100 psi [0 to 6.9 bar]
• Output: 4 to 20 mA
American Sensor Technologies Pressure Sensor
• AST range 0 to 300 psi [0 to 20.7 bar]
• Output: 4 to 20 mA
USC
®
Drinking WaterLow Lead ContentNSF/ANSI 61 & 372 File#: 009553_0_000
NSF/ANSI 61 (Drinking Water System Components - Health Effects) is a certification standard for products that come into contact with drinking water. NSF/ANSI 372 (Drinking Water System Components — Lead Content) verifies the lead content of drinking water products meets levels determined by the Safe Drinking Water Act. These requirements are based on EPA and Health Canada Requirement.