Page 1: Early Bird Discount & Registration - Apex Dubaiapex-dubai.com/brochures/ee_-_84_electrical_fault_analysis_causes... · This course is designed to provides the participants with complete

Early Bird Discount & Registration Register and pay 25 days prior to the event date and get 15% discount.

Registrations will close 15 days prior to the start of the Course.

Reserve Your Space Now!

CALL +971 4 445 8567

Page 2: Early Bird Discount & Registration - Apex Dubaiapex-dubai.com/brochures/ee_-_84_electrical_fault_analysis_causes... · This course is designed to provides the participants with complete

Electrical Fault Analysis Causes, Detection & Remedies

Copyright © 2016. APEX FZ LLC. All Rights Reserved www.apex-dubai.com

It is essential to know the Short Circuit Current and KVA that the system will carry under Different Fault Conditions

and at Different Points in the System. The faults may be Single Line to Ground, Double Line to Ground, Three Line

Fault or Line to Line Fault. Selection of Circuit Breakers, Protective Devices and Operation Strategies are mainly

required information about the Short Circuit Current.

Moreover Fault Analysis is essential in order to have safety operation of the Power Systems and to know the fault

causes. It is important for Engineers and Technicians to be aware by fault causes, fault detection, fault protection and

fault analysis. This course is designed to provides the participants with complete knowledge about fault calculations,

fault detection and protective relays used for power systems and networks. The course is concerned with the

calculation of fault currents in practical electrical power systems. Short-Circuit currents are associated with large

amounts of very destructive Energy and therefore Calculations must be made to ensure that the short-circuit ratings

of equipment are adequate to cater for these high currents. In addition, an accurate assessment of these currents is

also essential for determining the settings of the system protection devices.

Electrical systems are subjected to several external & internal influences like Weather Conditions, Lightning

Phenomenon, Pollution, Insulation Failure, Temperature Rise, etc., these influences cause abnormal Operational

Condition, which could lead to voltage and frequency variations and feeder trips, brown out or Black Out of Electrical

system, and sometimes, may lead to equipment damage or System Failure.

After completing this course, participants will be able to:

Understand the basic theory of Three Phase Power System

under Balanced and Unbalanced Conditions.

Learn the Per-unit System and Analytical Circuit based

Techniques to calculate Industrial Power Systems for Faults.

Learn Advanced Engineering Mathematical Software that can

be used to make difficult and complicated Calculations an

Easy Task.

Understand Balanced Three-phase Faults and unbalanced

Faults and their Analysis using Symmetrical Components.

Apply impedance reduction Techniques and positive, negative

and zero sequence circuits and their interconnection for faults.

Participate and earn valuable learning through Case studies

and industrial standards for Medium and Low Voltage

Networks and know what are types of different of Faults and

how faults are calculated.

The course is designed for Electrical

Engineers those involved in Commissioning,

Start up, Operation, and Protection of

Electric Power Networks.

Course Overview:

Course Objectives: Who Should Attend?

The Presentation, supplied documents,

and workshop exercises of the course

are in English however, based

on the trainees’ desires, oral presentation or

discussion can be Bilingual

(English and Arabic).

Course Language:

Page 3: Early Bird Discount & Registration - Apex Dubaiapex-dubai.com/brochures/ee_-_84_electrical_fault_analysis_causes... · This course is designed to provides the participants with complete

www.apex-dubai.com Copyright © 2016. APEX FZ LLC. All Rights Reserved

Electrical Fault Analysis Causes, Detection & Remedies

Module (01) Introduction to Fault Analysis

1.1 Source of Fault Current

1.2 Fault Statistics

1.3 Short-Circuit Rating of Equipment

1.4 Correct Switchgear Rating for Fault Duties

1.5 Per-Unit System

1.6 One-Line Diagrams

Module (02) Three Phase Short Circuit Currents

2.1 Calculation of Three Phase Short-Circuit Current

2.2 Circuit Reduction Techniques

2.3 Electricity Supply Systems

2.4 Tutorial - based on Attendees Plant

2.5 Cables Subjected to Short-Circuit Currents

2.6 Compliance with Regulations

Module (03) Unsymmetrical Fault Conditions

3.1 Overview of Symmetrical Components

3.2 Consideration of various Fault Types

3.3 Sequence Networks

3.4 Consideration of Phase Shift in Transformers

3.5 Consideration of Earth Impedance

3.6 Consideration of Three-winding Transformers

Module (04) Representation of Unsymmetrical Faults

4.1 Fault Diagrams

4.2 Interconnected Sequence Networks

4.3 Reference to limitation of Earth Fault Current

4.4 Demonstration based on Power Systems

Module (05) Earthing and Faults Current Level

5.1 Selection of Grounding Method / System

5.2 Understanding Ground Resistance

5.3 Ground Resistance Value & Measurements

5.4 Effect of Type of Earthing on Fault Current Level

Module (06) Transmission Lines and Feeders

6.1 Transmission Lines Faults

6.2 Line to Ground Faults

6.3 Phase Faults

6.4 Transmission Line Protection

6.5 Over Current & Earth Faults

6.6 Differential Relays

6.7 Successive Reclosing Method

6.8 Case Study

Module (07) Short Circuit Calculations

7.1 Three Phase Faults

7.2 Line to Line Faults

7.3 Line to Line to Ground Faults

7.4 Line to Ground Faults

7.5 Line to ground Faults through Impedance

7.6 Equivalents System Impedance

7.7 Current Limiting Inductors

7.8 Short Circuit Level

7.9 Effect of Induction Machines on Short Circuit Level

7.10 CB Rupture Capacity

7.11 Example of Short Circuit Calculations

Module (08) Transformers Faults Analysis

8.1 Types of Faults

8.2 Through Faults

8.3 Internal Faults

8.4 Phase Faults

8.5 Earth Faults

8.6 Gas Actuated Relays

8.7 Buchholz Relays

8.8 Electrical Relays, Differential, Restricted Earth

8.9 Transformer with Ground Neutral

Module (09) Schematic Drawing Fault Analysis

9.1 Keys of Electrical Schematic Drawings

9.2 Principles of Different Auxiliary Relays

9.3 Main Components of the Schematic Drawings

9.4 Fault Analysis by Using the Schematic Drawings

9.5 Case Study of Transformers Fault Analysis

9.6 Case Study of circuit breaker fault Analysis

9.7 Case Study of GIS System Fault Analysis

9.8 Case Study MCC and Load Centers Fault Analysis

Course Summary & Conclusion

Course Contents:

Page 4: Early Bird Discount & Registration - Apex Dubaiapex-dubai.com/brochures/ee_-_84_electrical_fault_analysis_causes... · This course is designed to provides the participants with complete

Copyright © 2016. APEX FZ LLC. All Rights Reserved www.apex-dubai.com

Electrical Fault Analysis Causes, Detection & Remedies

A confirmation will be sent upon your registration.

Note that full payment must be made prior to the

event. Only those delegates who have paid in full will

be admitted to the event. All payments should be to

APEX Account:

Bank Name : HSBC Bank Middle East limited,

Branch : Jebel Ali Branch, Dubai, UAE

IBAN No : AE020200000035626472101

Swift Code : BBMEAEAD

Closing of Registration will be two (2) weeks prior to

the course date.

APEX can assist and provide corporate rates for the

hotel accommodation.

Course fees will cover Course Materials, Certificate of

Participation, Coffee Breaks and Lunch.

In-House course is also available upon request and

can be customized as per client’s needs.

If you are unable to attend the course you may

send a substitute delegate.

Cancellation should be made 15 days prior to the

course conduction. Failure to cancel within 10 days

will be to pay the course fee in full amount.

Payment Methods:

Cancellation:

General Information:

Tel : +971 4 445 8567

Fax : +971 4 454 2910

Email : [email protected]

Website : www.apex-dubai.com

Contact us:

Registration Form:

Please fill the information below:

Nominee Name:

Company Name:

Position Title: Department:

Phone: Mobile:

Email:

Company Address:

Do you want to request this to be conducted as an In-House Course?

Date Required: No. of Participants:

Preferred Venue: Other Requirements:

Email : [email protected]

Fax : +971 4 454 2910

Website : www.apex-dubai.com

The amount of 4500 USD will be charged for the

course fee and Full Payment is required prior to

commencement of the course.

Course Fees: Registration Methods:

Please fill the required additional

information below

NO YES


Recommended