45
. . . Generate Stable GRAS Cleaners And Sanitizers ON DEMAND Using 0 . 05 % Pure Salt, Pure Water And Clean 120 V converted to DC Power On - Site! ELECTRO - CHEMICAL ACTIVATION a div of JDP, Inc. Thomas Johnson; CEO
Transcript

.

.

.

Generate Stable GRAS Cleaners And Sanitizers ONDEMAND Using 0.05% Pure Salt, Pure Water And Clean120V converted to DC Power – On-Site!

ELECTRO-CHEMICAL ACTIVATION

a div of JDP, Inc.

Thomas Johnson; CEO

ECA; Laws of Electrolysis, by

© your company name. All rights reserved.

Title of your presentation

Michael Faraday; 1834

• Apprentice To Sir Humphrey Davy

• Tesla’s Mentor

• “Father” Of The Electric Motor

• Author Of Magnetic Field Theory

• Author Of Faraday’s Laws Of Electrolysis

• We Use The Most Advanced, State Of The Art ECA Devices Featuring Modular Laminar Flow Through Dielectric Membrane Cells Simultaneously Generating Non-toxic Cleaners And A Uniquely Powerful, Broad Spectrum Non-toxic Sanitizer

WORLD CLASS AUTOMATED ECA SYSTEMS

Three models; UL-75a “mini”, UL02, UL04.

Mini Ultra-Lyte produces 176 gpdof 800-1000 ppm FAC, or 320GPD of 200ppm FAC anolyte with pH 6.0

Anolyte remains stable for up to 120 days with <50% reduction in FAC

Catholyte production is 50% of anolyte production rate, with a pH 12.0.

PLC network ready, float level control or manual operation, program “recipes”, auto deliming feature

Cell guaranteed (prorated) for 6,000 hours, some have survived triple that…

DILUTE BRINE ELECTROLYSIS

OUR KEY DIFFERENCESWe Do Not Sell Machines – We Coach Our Clients In their use of the latest State Of The Art Technologies for generating on-site cleaners and sanitizer/disinfectants.

We develop new prerequisite programs With New Policies And Procedures based our copyrighted protocols, each of which exceeds the Minimum International Or National codified standards for Safety And Efficacy of cleaning and sanitizing solutions.

We Are HACCP/Food Safety Technology And Infection disease transmission prevention and remediation experts

We are Produce Safety experts too. See U.S. Patent 8282974, Oct 9, 2012.

We Work With Any And All Mfgrs Of On-site Devices.

We Select The Ideal Device, Devices And Protocols For Each Of Our Clients Needs.

The most stable ECA solutions with the lowest corrosivity and greatest operational benefits currently known come from the most advanced form of dilute brine electrolysis.

Only (2) companies in the world can produce the high character of solutions we demand. Clarentis Technologies LLC is our spec ECA device.

We build our own ancillary and dosing systems, and provide all training and service

NOTHING - IS GREENER…

Table salt

Drinking water

Household power (120V) HOCl is up to 300X more

effective than bleach, and its non-toxic!

HOClHypochlorus Acid

Hypochlorous acid has a number of uses, most of which take advantage of its strong oxidizing properties which allow it to be used as a bleach and disinfectant among many other things. Unlike covalently bonded acids, HOCl is an ionically bonded aqueous solution and does not “burn” skin, eyes or mucosal membranes.

Hypochlorous acid is the most effective of all the chlorine forms, yet is similar in structure to water. The germicidal efficiency of HOCl is due to the relative ease with which it can penetrate cell walls (lyses) . This penetration is comparable to that of water and can be attributed to both its modest size and to its electrical neutrality.

Anolyte, produced by ECA processes, possesses a physical character that transcends its analytical chemistry. Tiny gas bubbles have extremely strong ionic activity along their boundaries.

Most effective biofilm control, destroying mold, fungi and all micro-organisms including virus. Destroy proteins with time and concentration by disassociating EPS.

HOCl PROPERTIES• Addition of chlorine to water gives both hydrochloric acid (HCl) and

hypochlorous acid (HOCl, which is sometimes annotated as HClO):• Cl2 + H2O « HClO + HCl• In organic synthesis, HOCl converts alkenes to chlorohydrins.• In ECA systems that electrolyze H2O and NaCl, there is no HCl.• ECA is the mechanization of a biological system; bio-mimicry in its finest form.

In biology, hypochlorous acid is generated/activated in neutrophils by myeloperoxidase-mediated peroxidation of chloride ions contributing to the destruction of invading microorganisms

Where physiological saline is 0.9%, we use <0.1% pure NaCl in pure H2O to generate a neutral pH sanitizer (anolyte) and simultaneously a high pH amphoteric surfactant (catholyte).

No human or animal can develop has ever deveoped a sensitivity to anolyte exposures.

AN IMMUNE SYSTEMS MECHANICAL

ANALOG – IS NOW AUTOMATED Water Electrolysis; Based On The Laws Of Electrolysis; Michael Faraday, 1834

Pathogens have no possible adaptive resistance to properly prepared ECA anolytes

ECA is a form of combustion physics; its cold plasma electro-chemistry

UNIQUE DISINFECTION PROPERTIES

A combination of effects; chemical and physical increasing biocidal affect 100-300 times over bleach!

The solution is in a temporary “meta-stabilized” state of activation

Physical affects reduced in 96 hoursClarentis patented design retains chemical character (FAC) for up to 180 days.

Combustion cold-plasma physics of water and salts Ions are highly reactive free radicalsCatholyte penetrates dirt and biofilms due to surface tension alteration and water cluster reductionBoth solution exhibit high density of micro bubbles that rapidly cavitate emitting intense energy similar to ultrasonication treatmentsThe amount of physical damage done to microbes makes repair or resistance extremely difficult and unlikely

9

HOW DOES IT WORK?

The Core Technology Is A Method Of Transferring constant electrical energy to a moving thin film of water

containing a small amount of salt

Ensuring that the entire film of water is treated evenly

Using special catalytic coatings on titanium electrodes

Using an ion permeable membrane, separating the ion species into TWO

opposing polarized streams; one a cleaner/surfactant with a high pH and

reduced surface tension (catholyte), the other a powerful, broad spectrum

sanitizer/disinfectant (anolyte - HOCl)

Reverts to tiny desiccant mineral crystal (salts) when H2O evaporates –

there no toxic alkaline film residues typical of detergents and/or chemical

sanitizers such as quats, bleach, hydrogen peroxide, iodine & chloramines.

The ONLY additive is the PUREST form of SALT - dissolved in water

ECA cell in lower right is formed of a large diametertubular titanium anode with a smaller diametertitanium cathode tube nested inside. The twotubes are separated by a dielectric membrane thatallows electrons to pass thru, but no molecules.

STATE-OF-THE-ART ELECTRO-CHEMICAL ACTIVATION SYSTEMS

11

Our Systems SimultaneouslyGenerate Non-toxic Anolyte Sanitizers And Catholyte Cleaners From A Dilute Brine.

Clarentis UL75a “Mini”

© Johnson Diversified Products, Inc..Food Safety, Risk Management And The Evolution Of Commercial Kitchens

Rental Units Are Automatic,Mobile “Plug-N-Play” complete with water softener and every -thing else needed for self-contained operation

ELECTRO CHEMICALLY ACTIVATED SOLUTIONS

12

Physical and chemical changes occur:

• Molecular cluster sizes decrease• Kinetic energy equivalent to 80oC water is stored but water remains cool•Cold liquid plasma micro bubbles are formed with strong ionic activity

The effects of this are:•Better penetration•Even distribution of redox elements•Better transport of redox elements•Constant electron transition of redox elements•Bubble implosion like ultrasonication

Ice

Emulsion

Fog

Foam

Spray

Coldplasma

Mist

Liquid

Gel

ECA SOLUTIONS

CAN BE USED IN ANY OF THESE FORMS, MAINTAINING ITS CHARACTERISTIC PROPERTIES

ECA SOLUTIONS REPLACE :

Quats, peracetic acid (PAA), hydrogen peroxide formulations such asthe brands Virox, Virkon, Oxiver Five 16 along with sodiumhypochlorite (bleach), sodium hydroxide (caustic soda), Cl, O3, ClO2and more…

Detergents in dishwashers (automatic remote dosing), windowcleaners and all floor cleaners.

Carpet cleaning solution's and deodorizers (Zerorez - uses Clarentis)

All sanitizers and disinfectants

Floor and surface cleaners, both machine and manual.

Risks to employee’s and the public associated with exposures to toxicchemical concentrates typically used to clean and disinfect hygienesensitive surfaces and spaces.

Chemical oxygen demand (COD) associated with toxic chemicalresidues and discharges typical in the janitorial sanitation field.

JRS INTEGRATIONS

The ECAS device to the right automatically doses thedish machine below it.

Johnson Risk Services provides and installs allnecessary components from custom reservoirs todemand and boosted pumps, dosing systems and allof the materials and supplies needed to easyoperations and continuous use

Nationwide ECAS Pioneers and Experts in the U.S. Food industry ECAS

protagonists since 1999.

Clarentis UL-75a mini – a fully automatic device with remote tank level control capability. Above includes ancillary direct-connect dishwasher interface

HENNEPIN COUNTY ADULT CORRECTIONAL FACILITY, MNDesigner; Terry Pellegrino, Robert Rippe Assoc.

Wall mounted automatic UL-75a “mini” generates cleaning non-toxic solutions for the dishwasher, for general use and approved food contact surface sanitizers (40 CFR 180.940; FDA 7-204.11; HOCl)

Secondary ancillary system from JDP automatically doses their 86”Stero conveyor dish machine. ECA system is “remote” in another room, 10’ from dish machine

“Inmates can’t hurt themselves or others with these products”

18

STATE OF THE ART SUSTAINABILITYSurly (Destination) Brewery, MinneapolisDirect Connected to FIVE Dish Machines!!

Designer:Steve Carlson, President

Robert Rippe Assoc.

1 conveyor, 1 doorand 3 glass washersserved by (2) mini’srun in parallel tied tocommon reservoirs.

Glass washers are onlevel two. Nearestdish machine is 30’away; most remotemachine is 110’ away.

ECA machine is over 250 feet away from dish washer!

Automatic ECA device with ancillary float level control reservoirs elevated to fill floor cleaning machines

North EducationCenter, Plymouth

Nova controller doses catholyte into high temp dish washer tank

.

.

.

ULTRA-LYTE 75A “MINI’S”-ASMOBILE PLUG-N-PLAY ECASMODULES; EXCLUSIVELY BY JDP, INC

Full Auto Generator module Mobile Concentrate module

MOBILE MINI’S ENROUTE TO PURDUE UNIV. FOR MELON

RESEARCH STUDY

Solutions Applications

Anolyte

Broad spectrum sanitizers

Produce wash and fog dispersion

Beverage line sanitizing for biofilm control

General purpose disinfectant

Norovirus control and a powerful virucide

Mold remediation

Biological control for LM, Legionella, water systems, pools, laundry and more

Catholyte

Amphoteric surfactant for cleaning with no film residue –no biofilm matrix

No COD component to effluent

Dishwasher dosing

Carpet and floor cleaning

General decontamination

Coach, car and cart wash

Biofilm control

EVOLVED SANITARY

OPERATIONS PLATFORMS®

Prerequisite Programs are Customized For Each Client/Customers Operation Using Environmental And Food HACCP – WITH ECA

Two-step Process Uses Catholyte to decontaminate and VERIFY’s CLEANAnolyte is sprayed onto clean surface to SANITIZE

SEPTEMBER ‘13 INSTALL ON THE GOLDEN PRINCESS CRUISE SHIP

A new, Norovirus control strategy proven to provide statistically significant improvement in reducing risk of transmission

ATP METERS PROVIDED BY JRS/JDPALONG WITH ESOP TRAINING

Because we measure “CLEAN” quantitatively, using ATP, we ensure clean surfaces prior to surface sanitizing.

!

THE CREW IS HAPPY TO BE DONE WITH VIROX - WHICH RUINED THEIR HANDS

© Johnson Diversified Products, Inc..

Food Safety, Risk Management And The Evolution Of Commercial Kitchens

CROWN, GOLDEN AND STAR PRINCESS CRUISE SHIPs INSTALLATION; IMPLEMENTED “ESOPs” FOR EFFECTIVE, CLEANING, SANITIZING FOR DISEASE TRANSMISSION PREVENTION

Ready To Use Sanitizer, 200ppm FAC

ConcentratedSanitizer, 1,100ppm FAC

(2) ECA SystemsClarentisTech, LLC

SALT

SALT

BRINE

BRINE

27s

COMPELLING DATA, LOW 150PPM FAC;5 LOG REDUCTION IN ONLY 1 MINUTE!

ONE MACHINE REPLACES ALL VIROX SANITIZERS AND DISINFECTANTS USED FOR NOV CONTROL

NYC INSTALLATION PHOTOS

ECA Device with auto float control in oversized tanks

Proportioning station for fruit and produce

Proportioning for best practice hand sanitizer

Old style DEMA injection fitting for catholyte replacing dish machine detergentWhole Foods,

Union SquareManhattan, NY (sold and

serviced by our channel partnerS, Ecologic

Solutions).

Mobile Ul-75A “mini”

Fully automatic, 110 or 220V

Produces stable HOCl anolyte selectable from 150-1100 PPM FAC pH 5.8-7.2; pH 12.5 catholyte cleaner (hydroxyl radical)

Plug and play modules set up quickly

COSTS AND OPTIONS

Mini base units start at $23K, larger units range from $40K to $65K

Mobile modules with ancillaries and water softener add $12K

Add for other options for connecting to dish washers or remote mixing/dosing, crates, etc.

Lease programs and rentals too.

3 – 4X SHELF LIFE EXTENSION FOR BERRIES!400% increase in profits!

100PPM FAC Ultra-Lyte in unique Ultrasonic fogger with “Double Dome” from Diligence Corp.

Fogging systems for retail cases, cold rooms, containers and trailers

Anolyte destroys all known pathogens

Catholyte disrupts biofilm adhesion

No film residues from anolyte or catholyte

Harmless to humans and environment

Non-Toxic; a true “GREEN” technology

AFFORDABLE, SUSTAINABLE, EFFECTIVE

OTHER USES FOR ECA?Floor cleaning and sanitizing; hard surface and carpets

Lavatories, shower and locker rooms, walk-off mats, gear and clothing cleaning, disinfection and deodorization, commercial laundry

Remediation; mold, flood, fire, infectious disease

Biofilm control

Legionella, CIP, narrow bore water line (DUWl)

Cooling tower and all other evaporative uses

Listeria control; drain hygiene systems, animal husbandry vet medicine

Swimming pools, hot tubs/spa’s, no more bromine!

Potable water disinfection - no risk of chlorine tolerant strains of water borne micro-organisms.

General cleaning and disinfection; excellent anti viral is non-toxic

APPROVALS AND USEU.S. Patent 8,282,974, Oct 9th, 2012 http://tinyurl.com/aqtzf5c

EPA Label; when distributers package and sell in container: http://clarentistechnologies.com/storage/Final%20EPA%20Label%20Clarentis-2.pdf

Infection control eg., Norovirus (CDC VSP)

FDA Food Code 7-204.11 and 4-501.114

Grade A Pasteurized Milk Ordinance (PMO) per NCIMS

CFRs40 CFR 180.940

4o CFR 152.500

40 CFR 156.10

21 CFR 173.315

On-Site generated pursuant to ESOP®; Generally Recognized As Safe (GRAS)

Specialized ValidationU.S. Patent 8,282,974, Tandem use of Catholyte and Anolyte to Clean and sanitize Fruit and Vegetables (Dole), Thomas Johnson, first named inventor, Oct 9th, 2012

Antiviral activity of Ecasol (anolyte) against feline calicivirus a surrogate of human norovirus, Journal of Infection of Public Health, December, 2012

Many others relating to diverse applications; eg., mold remediation, sporocidal, fungicide, broad spectrum antibacterial vs MRSA, C. diff., protozoa and oocysts; blood pathogens. Can be aerosolized; fogged.

http://cfpub.epa.gov/si/si_public_record_Report.cfm?dirEntryId=238135

Used by the U.S. Army rangers and other armies of the world for biological, chemical and nuclear decontamination and remediation regimes.

Validated Antiviral

NoV

H3N2

H1N1

WHAT OTHER PROOF?University of MN/ Journal of Infection and Public Health, Dec, 2012, NoV control:

http://tinyurl.com/d6f5d2p

MSDS

Food contact surface sanitizer reports

Non-toxic(cytotoxicity) documentation

ATS Labs NoV reports

ATS Swine and Avian Influenza reports

Legionella papers

EPA Reports

A FEW JRS ECA CLIENTSPrincess Cruises 2013 - present

Surly Brewery, Minneapolis – 2014 to present

Adult Correctional Facility (Hennepin County; since 2007)

North Education Center, New Hope, MN; Speciall Intermediate School District 287

Dole Fresh Vegetables (Soledad, CA since 2008)

Viking Coke (St. Cloud, MN since July 2010 - for CIP systems)

*Whole Foods, Union square pls (27) other stores in the NE (see pictures next slide, since October 2010).

*Statue of Liberty Foundation, AmTrak (2012)

USDA ARS; BARC and Philadelphia.

Clean Response and Catastrophe Response (Remediation Experts, St. Paul, MN since March 2011)

Zerorez Carpet Cleaning, Richfield, MN, 2011

MN ISD 287 North Education Center, since 9/2012

U.S. Armed Forces; Homeland security ( EPA 600/R-11/124 | October 2011 | www.epa.gov/ord)

* Ecologic Solutions Inc. was our NYC Distributer/Partner and these were their customers. http://www.ecologicsolutions.com

CLARENTIS CERTIFICATIONSListed by CSA to ANSI UL 979

Labeled with EPA Establishment number

Reservoirs are labeled with contents, MSDS information and dilution instructions ; 40 CFR 152.10

Anolyte solution approval; 40 CFR 180.940, FDA 7-204.11

Provided with owners manual, test strips and user training

Thomas W. Johnson

Johnson Diversified Products, Inc. Food Safety Technology; HACCP (HARPC) and PRP writer and Implementer. Food Equipment And Systems Expert; Consultant to Manufacturers and Associations.Infection Control Expert; Evolved Sanitary Operations Platform® (ESOP)Original Author and Current IP Owner.Protagonist, ECA And ‘On-Site Device’ Expert Since 1999Deep, Decades Long Experience with National And Local Regulatory Compliance As Well As Is Due Diligence Associated With Claims And Intended Uses For ECA ‘Electrolytes’.Codes and Standards Development Organization Memberships; 26yrsOver A Decade Of Integration/Implementation Experience Installing, Servicing, along with ECA Systems Certification Learning Programs For Crews in Hygiene Sensitive Facilities.

Broad, Extensive “Who’s - Who” List Of Local, Regional, National And Global References, Principals, Clients and Customers

https://www.linkedin.com/profile/view?id=12998541&trk=nav_responsive_tab_profile

More info?Contact: Thomas Johnson

Email: [email protected]: 651-203-2462

Cell: 651-587-0418

.

.

.

http://www.Jrsrisk.com http://www.jdpinc.com http://www.evolvedkitchens.com